HRS FH12-19S

0.5mm and 1mm Pitch Connectors For FPC/FFC
FH12 Series
Flip-lock
■Features
1. Ease of Use and Space Savings
Only one finger or 6.9N (Newtons) of force is required to
lock Hirose’s rotational actuator (flip-lock) as compared
to using 2 fingers and 39.2N to close a FFC/FPC
connector from our competition.
Rotating One-touch Mechanism
q
The Flip-Lock design also allows customers to place 2
or more connectors side by side as there is no need to
waste additional board space for a side latch.
2. Strengthened Flip-lock Actuator
The standard Flip-Lock requires only 2.0mm height
above the board. A strengthened lock lever is available
which only requires an additional 0.4mm.
w
3. Supports Thin FPC (0.18mm)
Hirose does not require double-sided FPC to have any
additional strengthening plate or stiffener and can therefore
support a thickness of as little as 0.18mm +/- 0.05.
4. Hirose Ensures Reliability
Hirose’s patented half tuning fork contacts maintain the
required normal force without relying on the connector
housing. With our competitor’s conventional products
the housing walls support the contact force, which does
not provide for long-term reliability.
5. Prevention of Solder Bridge
Excess solder cavity absorbs excessive solder and
avoids solder bridging.
6. Three different assembly types
FH12 is offered in Top & Bottom Contact and Vertical
Mount and offered in both a 0.5mm contact pitch as well
as a 1.0mm contact pitch (bottom contact only).
■Applications
Notebook computers, printers, PDAs, digital cameras and
other compact devices for interconnecting the main circuit
board with the LCD, HDD or other device.
6
e
■Product Specifications
Current rating: 0.4A DC Operating Temperature Range:_40 to +70ç (Note 1) Storage Temperature Range:_10 to +50ç (Note 2)
Rating
Voltage rating: 50V AC
Operating Humidity Range:Relative humidity, 90% max. Storage Humidity Range:Relative humidity, 90% max.
(Not dewed)
Applicable FPC
t=0.3±0.05 Tin-lead plating(Note 3)
(Not dewed)
t=0.18 ± 0.05 for FH12F-*S-0.5SH
Item
1. Insulation resistance
2. Withstanding voltage
3. Contact resistance
Specification
500M ohms minimum
No flashover or insulation breakdown.
50m ohms maximum
Conditions
4. Durability (Insertion/withdrawal)
Contact resistance: 50m ohms maximum
No damage, cracks, or parts dislocation.
20 cycles
5. Vibration
No electrical discontinuity of 1µs or more
Contact resistance: 50m ohms maximum.
No damage, cracks, or parts dislocation.
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
2 hours in each of the 3 directions.
6. Shock
No electrical discontinuity of 1µs or more
Contact resistance: 50m ohms maximum.
No damage, cracks, or parts dislocation.
Acceleration of 490 m/s2, 11 ms duration,
sine half-wave waveform, 3 cycles in each of the 3 axis.
100V DC
150V AC/1 minute
1mA
Contact resistance: 50m ohms maximum.
7. Humidity(Steady state) Insulation resistance: 50M ohms minimum.
No damage, cracks, or parts dislocation.
8. Temperature Cycle
96 hours at temperature of 40ç and humidity of 90% to 95%
Contact resistance: 50m ohms maximum.
Insulation resistance: 50M ohms minimum.
No damage, cracks, or parts dislocation.
5 cycles under conditions as follows;
Temperature: -40ç / 15 to 35ç / 85ç / 15 to 35ç,
Time: 30 / 5 max. / 30 / 5 max.(minutes)
No deformation of
Reflow: At the recommended temperature profile
Manual soldering: 350±5ç for 3 seconds
components affecting performance.
Note 1: Includes temperature rise caused by current flow.
Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers nonconducting condition of installed connectors in storage, shipment or during transportation.
Note 3: When FPC is gold plated, the connector contacts should be also gold plated: Select the (05) specification.
9.Resistance to Soldering heat
■Material
Part
Material
Polyamide
PPS
Phosphor bronze
Brass
Insulator
Contact
Macal Fittings
Finish
Color : Beige
Color : Dark brown
Tin-lead plating
Tin-lead plating
Remarks
UL94V-0
–––––––
■Ordering Information
FH12
q
A - 10 (4) - S A - 0.5 SH (05)
w
e
r
q Series Name
: FH12
w Blank : standard type
A : Top contact type
S : Type with strengthed flip-lock actuator
F : Type with 0.18mm FPC End Thickness
e Standard type : Number of contacts
Eccentric type : Number of contacts in 0.5mm housing
r Standard type : Blank
Eccentric type : Number of contacts
t
y
u
i
o
t Contact alignment: Single
y Eccentric direction:
Blank : standard type
A : Eccentric type
u Contacts Pitch : 0.5mm, 1mm
i Contact type
SH : SMT horizontal mounting type
SV : SMT vertical mounting type
o Plating specification
Blank : Tin-lead plating
(05) : Gold plating
7
BSeries Configuration
Pitch
Bottom Contact Type
Top Contact Type
Vertical mounting Type
FPC conductive surface
(bottom side)
FPC conductive
surface
FH12- ** S-0.5SH
P.12
Number of contacts 6, 10, 11, 12, 13, 14,
15, 16, 17, 18, 19, 20,
0.5mm
22, 24, 25, 26, 28, 30,
32, 33, 34, 36, 40, 45,
50, 53
Type with Strengthened Lock Lever
FH12S- ** S-0.5SH
P.13
Number of contacts 30, 40, 45, 50, 53
Type with 0.18mm FPC End Thickness
FH12A- ** S-0.5SH
FH12F- ** S-0.5SH
P.14
Number of contacts 6, 10, 12, 13, 14, 15, 16,
18, 20, 22, 24, 26, 28,
30, 32, (33), 34, 36, 40
P.15
Number of contacts 10, 12 ,15, 16, 18, 20,
22, 24, 26, 28, 29, 30,
32, 33, 34, 36, 40, 42,
45, 50
FH12- ** S-0.5SV
P.16
Number of contacts 10, 12, 13, 15, 16, 17,
18, 20, 22, 24, 26, 30,
32, 33, 34, 36, 40, 45,
49, 50
FPC conductive surface
(bottom side)
1mm
Standard FH12- ** S-1SH
P.18
Eccentric FH12- ** (**) S-1SH
Standard
Number of contacts 5, 6, 7, 8, 9, 11,
16, 22, 26
Eccentric
FH12- ** S-1SV
Number of contacts 6, 7, 8, 16, 20, 22,
Number of contacts 4, 6, 8, 10, 11,
14, 19, 24
8
P.19
24
BConnector Operating Instructions, precautions and recommendations
●Bottom Contact Type (common for 0.5mm/1mm)
Operation
Precautions
1. FPC/FFC Termination procedure.
Connector installed on the board.
1) Avoid grasping the actuator with two fingers or lifting the actuator with fingernail.
1) Lift up the actuator. Use thumb or index finger.
2) Rotate down the actuator until firmly closed.
It is critical that the inserted FPC/FFC is not moved
and remains fully inserted. Should the FPC/FFC be
moved, open the actuator and repeat the process,
starting with Step 1 above.
2) Fully insert the FPC/FFC parallel to mounting surface, with the exposed conductive traces facing
down.
Stiffener
FPC/FFC conductive traces
2. FPC/FFC Removal
1) Lift up the actuator.
2) Carefully remove the FPC/FFC.
3) Due to the structure of the connectors, they do
not have strong resistance to upward pulling;
therefore, support the FPC/FFC when a pulling
force is applied to it.
9
●Top Contact Type
Operation
Precautions
1. FPC/FFC Termination procedure.
Connector installed on the board.
1) Avoid forcing the actuator up or down without the
FPC/FFC inserted.
1) Lift up the actuator. Use thumb or index finger.
2) Fully insert the FPC/FFC parallel to mounting surface, with the exposed conductive traces facing
UP.
a
are
ion
t
r
nse
Ci
FP
FPC/FFC conductive traces
2) When closing down the actuator apply equal pressure to both sides of the actuator.
Stiffener
3) Rotate down the actuator until firmly closed.
It is critical that the inserted FPC/FFC is not moved
and remains fully inserted. Should the FPC/FFC be
moved, open the actuator and repeat the process,
starting with Step 1 above.
3) Avoid forced pulling of the FPC. Forced pulling
will cause the FPC to become disconnected or
damaged.
2. FPC/FFC Removal
1) Lift up the actuator.
2) Carefully remove the FPC/FFC.
10
●Vertical Mounting Type
Operation
1. FPC/FFC Termination procedure.
Connector installed on the board.
Precautions
1) Avoid forcing the actuator up or down without the
FPC/FFC inserted.
1) Verify that the actuator is positioned upright. If the
actuator has rotated to the side, carefully rotate it
upright.
Actuator upright
2) Insert the FPC/FFC vertically in the connector slot
assuring that the conductive traces of the
FPC/FFC are facing away from the actuator.
Stiffener
FPC/FFC conductive traces
Sl
ot
3) Press down the actuator in the direction shown.
2. FPC/FFC Removal
Rotate the actuator upward and withdraw the
FPC/FFC.
11
■0.5mm Pitch Bottom Contact Type
A
0.5
( 0.2)
1.2
2
0.8
Mated Cross-sectional Diagram
FPC/FFC Contact Surface
(2.1)
(3.1)
2
(4.8)
2
1.85
B
C
D
Unit:mm
Note 2
Part Number
CL No.
Number of Contacts
A
B
C
D
FH12-06S-0.5SH
586-0582-5
6
02.5
06.1
07.1
03.57
FH12-10S-0.5SH
586-0522-3
10
04.5
08.1
09.1
05.57
FH12-11S-0.5SH
586-0600-5
11
05.0
08.6
09.6
06.07
FH12-12S-0.5SH
586-0704-0
12
05.5
09.1
10.1
06.57
FH12-13S-0.5SH
586-0549-0
13
06.0
09.6
10.6
07.07
FH12-14S-0.5SH
586-0533-0
14
06.5
10.1
11.1
07.57
FH12-15S-0.5SH
586-0523-6
15
07.0
10.6
11.6
08.07
FH12-16S-0.5SH
586-0531-4
16
07.5
11.1
12.1
08.57
FH12-17S-0.5SH
586-0606-1
17
08.0
11.6
12.6
09.07
FH12-18S-0.5SH
586-0530-1
18
08.5
12.1
13.1
09.57
FH12-19S-0.5SH
586-0534-2
19
09.0
12.6
13.6
10.07
FH12-20S-0.5SH
586-0524-9
20
09.5
13.1
14.1
10.57
FH12-22S-0.5SH
586-0532-7
22
10.5
14.1
15.1
11.57
FH12-24S-0.5SH
586-0521-0
24
11.5
15.1
16.1
12.57
FH12-25S-0.5SH
586-0692-3
25
12.0
15.6
16.6
13.07
FH12-26S-0.5SH
586-0576-2
26
12.5
16.1
17.1
13.57
FH12-28S-0.5SH
586-0612-4
28
13.5
17.1
18.1
14.57
FH12-30S-0.5SH
586-0525-1
30
14.5
18.1
19.1
15.57
FH12-32S-0.5SH
586-0681-7
32
15.5
19.1
20.1
16.57
FH12-33S-0.5SH
586-0520-8
33
16.0
19.6
20.6
17.07
FH12-34S-0.5SH
586-0617-8
34
16.5
20.1
21.1
17.57
FH12-36S-0.5SH
586-0526-4
36
17.5
21.1
22.1
18.57
Note 2
FH12-40S-0.5SH
586-0527-7
40
19.5
23.1
24.1
20.57
Note 2
FH12-45S-0.5SH
586-0528-0
45
22.0
25.6
26.6
23.07
Note 2
FH12-50S-0.5SH
586-0529-2
50
24.5
28.1
29.1
25.57
FH12-53S-0.5SH
586-0595-7
53
26.0
29.6
30.6
27.07
Note 2
Note 1 : Embossed tape reel packaging (2,000 pieces/reel).
Order by number of reels.
Note 2 : If there is no problem with the connector height, we recommend the type with the
strengthened Flip-lock actuator (FH12S-*S-0.5SH).
Standard type connector height: 2 mm
Connector height of type with strengthened Flip-lock actuator: 2.4 mm
12
4.6
5.6
(1.3)
■0.5mm Pitch Bottom Contact Type with Strengthened Flip-lock Actuator
Mated Cross-sectional Diagram
1.2
2
0.8
A
0.5
( 0.2 )
FPC/FFC Contact Surface
( 2.1)
( 3.1 )
( 1.3 )
2.25
D
2
2.4
( 4.8 )
B
C
4.6
5.6
Unit:mm
Part Number
CL No.
Number of Contacts
A
B
C
D
FH12S-30S-0.5SH
586-0667-6
30
14.5
18.1
19.1
15.57
FH12S-40S-0.5SH
586-0640-0
40
19.5
23.1
24.1
20.57
FH12S-45S-0.5SH
586-0665-0
45
22.0
25.6
26.6
23.07
FH12S-50S-0.5SH
586-0642-5
50
24.5
28.1
29.1
25.57
FH12S-53S-0.5SH
586-0691-0
53
26.0
29.6
30.6
27.07
Note: Embossed tape reel packaging (2,000 pieces/reel).
Order by number of reels.
13
■0.5mm Pitch Bottom Contact Type with 0.18mm FPC End Thickness
Applicable FPC end thickness : 0.18±0.05
A
0.5
( 0.2 )
1.2
2
0.8
Mated Cross-sectional Diagram
FPC Contact Surface
(2.15)
(3.15)
2
( 4.8 )
1.85
B
C
D
4.6
5.6
Unit:mm
Part Number
CL No.
Number of Contacts
A
B
C
D
FH12F-06S-0.5SH
586-0672-6
6
02.5
06.1
07.1
03.57
FH12F-10S-0.5SH
586-0709-4
10
04.5
08.1
09.1
05.57
FH12F-12S-0.5SH
586-0653-1
12
05.5
09.1
10.1
06.57
FH12F-13S-0.5SH
586-0629-7
13
06.0
09.6
10.6
07.07
FH12F-14S-0.5SH
586-0655-7
14
06.5
10.1
11.1
07.57
FH12F-15S-0.5SH
586-0680-4
15
07.0
10.6
11.6
08.07
FH12F-16S-0.5SH
586-0673-9
16
07.5
11.1
12.1
08.57
FH12F-18S-0.5SH
586-0626-9
18
08.5
12.1
13.1
09.57
FH12F-20S-0.5SH
586-0636-2
20
09.5
13.1
14.1
10.57
FH12F-22S-0.5SH
586-0630-6
22
10.5
14.1
15.1
11.57
FH12F-24S-0.5SH
586-0632-1
24
11.5
15.1
16.1
12.57
FH12F-26S-0.5SH
586-0627-1
26
12.5
16.1
17.1
13.57
FH12F-28S-0.5SH
586-0643-8
28
13.5
17.1
18.1
14.57
FH12F-30S-0.5SH
586-0628-4
30
14.5
18.1
19.1
15.57
FH12F-32S-0.5SH
586-0705-3
32
15.5
19.1
20.1
16.57
FH12F-33S-0.5SH
--------------------
33
16.0
19.6
20.6
17.07
FH12F-34S-0.5SH
586-0677-0
34
16.5
20.1
21.1
17.57
FH12F-36S-0.5SH
586-0656-0
36
17.5
21.1
22.1
18.57
FH12F-40S-0.5SH
586-0635-0
40
19.5
23.1
24.1
20.57
Note: Embossed tape reel packaging (2,000 pieces/reel).
Order by number of reels.
14
(1.25)
■0.5mm Pitch Top Contact Type
A
B
C
Mated Cross-sectional Diagram
0.5
(0.2)
(1.9)
FPC/FFC Contact Surface
(1.45)
(1.85)
2
(5)
6.2
2
(3.6)
D
E
(0.45)
0.8
2.2
0.85
1.45
Unit:mm
Part Number
CL No.
Number of Contacts
A
B
C
D
E
FH12A-10S-0.5SH
586-0550-9
10
9.1
8.35
4.5
9.5
5.57
FH12A-12S-0.5SH
586-0696-4
12
10.1
9.35
5.5
10.5
6.57
FH12A-15S-0.5SH
586-0551-1
15
11.6
10.85
7.0
12.0
8.07
FH12A-16S-0.5SH
586-0552-4
16
12.1
11.35
7.5
12.5
8.57
FH12A-18S-0.5SH
586-0553-7
18
13.1
12.35
8.5
13.5
9.57
FH12A-20S-0.5SH
586-0554-0
20
14.1
13.35
9.5
14.5
10.57
FH12A-22S-0.5SH
586-0686-0
22
15.1
14.35
10.5
15.5
11.57
FH12A-24S-0.5SH
586-0555-2
24
16.1
15.35
11.5
16.5
12.57
FH12A-26S-0.5SH
586-0663-5
26
17.1
16.35
12.5
17.5
13.57
FH12A-28S-0.5SH
586-0725-0
28
18.1
17.35
13.5
18.5
14.57
FH12A-29S-0.5SH
586-0585-3
29
18.6
17.85
14.0
19.0
15.07
FH12A-30S-0.5SH
586-0556-5
30
19.1
18.35
14.5
19.5
15.57
FH12A-32S-0.5SH
586-0687-3
32
20.1
19.35
15.5
20.5
16.57
FH12A-33S-0.5SH
586-0570-6
33
20.6
19.85
16.0
21.0
17.07
FH12A-34S-0.5SH
586-0670-0
34
21.1
20.35
16.5
21.5
17.57
FH12A-36S-0.5SH
586-0662-2
36
22.1
21.35
17.5
22.5
18.57
FH12A-40S-0.5SH
586-0557-8
40
24.1
23.35
19.5
24.5
20.57
FH12A-42S-0.5SH
586-0698-0
42
25.1
24.35
20.5
25.5
21.57
FH12A-45S-0.5SH
586-0558-0
45
26.6
25.85
22.0
27.0
23.07
FH12A-50S-0.5SH
586-0559-3
50
29.1
28.35
24.5
29.5
25.57
Note 1 : Embossed tape reel packaging (2,000 pieces/reel).
Order by number of reels.
Note 2 : The design is such that the FPC/FFC protrudes on an upward angle so that other
parts can be mounted beneath the PFC/FFC. In view of this, please take note of the
gap at the top surface of the connector.
15
■0.5mm Pitch Vertical mounting Type
Mated Cross-sectional Diagram
( 0.2 )
( 0.15)
FPC/FFC Contact Surface
(1.4 )
( 2.15 )
1
1
0.5
F
2.5
0.5
( 4.25 )
(1.75 )
3.6
5.5
( 4.85 )
A
B
0.5
3.8(Metal fitting dimension)
C
D
E
Unit:mm
Part Number
CL No.
Number of Contacts
A
B
C
D
E
F
FH12-10S-0.5SV
586-0560-2
10
08.4
06.9
04.5
06.5
08.2
4
FH12-12S-0.5SV
586-0615-2
12
09.4
07.9
05.5
07.5
09.2
4
FH12-13S-0.5SV
586-0575-0
13
09.9
08.4
06.0
08.0
09.7
4
FH12-15S-0.5SV
586-0561-5
15
10.9
09.4
07.0
09.0
10.7
4
FH12-16S-0.5SV
586-0572-1
16
11.4
09.9
07.5
09.5
11.2
4
FH12-17S-0.5SV
586-0601-8
17
11.9
10.4
08.0
10.0
11.7
4
FH12-18S-0.5SV
586-0573-4
18
12.4
10.9
08.5
10.5
12.2
4
FH12-20S-0.5SV
586-0562-8
20
13.4
11.9
09.5
11.5
13.2
4
FH12-22S-0.5SV
586-0589-4
22
14.4
12.9
10.5
12.5
14.2
8
FH12-24S-0.5SV
586-0563-0
24
15.4
13.9
11.5
13.5
15.2
8
FH12-26S-0.5SV
586-0664-8
26
16.4
14.9
12.5
14.5
16.2
8
FH12-30S-0.5SV
586-0564-3
30
18.4
16.9
14.5
16.5
18.2
8
FH12-32S-0.5SV
586-0699-2
32
19.4
17.9
15.5
17.5
19.2
8
FH12-33S-0.5SV
586-0565-6
33
19.9
18.4
16.0
18.0
19.7
8
FH12-34S-0.5SV
586-0706-6
34
20.4
18.9
16.5
18.5
20.2
8
FH12-36S-0.5SV
586-0641-2
36
21.4
19.9
17.5
19.5
21.2
8
FH12-40S-0.5SV
586-0566-9
40
23.4
21.9
19.5
21.5
23.2
8
FH12-45S-0.5SV
586-0567-1
45
25.9
24.4
22.0
24.0
25.7
8
FH12-49S-0.5SV
586-0602-0
49
27.9
26.4
24.0
26.0
27.7
8
FH12-50S-0.5SV
586-0568-4
50
28.4
26.9
24.5
26.5
28.2
8
Note 1 : Embossed tape reel packaging (1,000 pieces/reel).
Order by number of reels.
16
BRecommended FPC/FFC dimensions and Land/Metal Mask dimensions
●0.5mm Pitch Product
Product Type
C Dimension
Types other than 0.3±0.05min
those below
Stiffener thickness should be 0.188 mm (7.5 mil) min
Types with an FPC end
0.18±0.05
thickness of 0.18 mm
0.3±0.03(Land)
0.5±0.05
0.25±0.03(Metal mask)
A±0.05
Recommended metal mask thickness : 0.15mm
Unit: mm
6
10
11
12
13
14
15
16
17
18
19
20
22
24
A
B
02.5
04.5
05.0
05.5
06.0
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.5
11.5
03.5
05.5
06.0
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.0
10.5
11.5
12.5
Number
of Contacts
25
26
28
29
30
32
33
34
36
40
42
45
50
53
Unit: mm
A
B
Dimension
Number
of Contacts
12.0
12.5
13.5
14.0
14.5
15.5
16.0
16.5
17.5
19.5
20.5
22.0
24.5
26.0
13.0
13.5
14.5
15.0
15.5
16.5
17.0
17.5
18.5
20.5
21.5
23.0
25.5
27.0
6
10
11
12
13
14
15
16
17
18
19
20
22
24
A
B
02.5
04.5
05.0
05.5
06.0
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.5
11.5
08.1
10.1
10.6
11.1
11.6
12.1
12.6
13.1
13.6
14.1
14.6
15.1
16.1
17.1
C
Dimension
Number
of Contacts
A
B
C
04.5
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.0
10.5
11.0
11.5
12.5
13.5
25
26
28
29
30
32
33
34
36
40
42
45
50
53
12.0
12.5
13.5
14.0
14.5
15.5
16.0
16.5
17.5
19.5
20.5
22.0
24.5
26.0
17.6
18.1
19.1
19.6
20.1
21.1
21.6
22.1
23.1
25.1
26.1
27.6
30.1
31.6
14.0
14.5
15.5
16.0
16.5
17.5
18.0
18.5
19.5
21.5
22.5
24.0
26.5
28.0
0.5±0.05
0.5±0.1
0.35±0.03(FPC)
0.3±0.05
1±0.05
1±0.05
0.6±0.1(Land)
B±0.05
Number
of Contacts
10
12
13
15
16
17
18
20
22
24
A
B
04.5
05.5
06.0
07.0
07.5
08.0
08.5
09.5
10.5
11.5
05.5
06.5
07.0
08.0
08.5
09.0
09.5
10.5
11.5
12.5
Dimension
Number
of Contacts
26
30
32
33
34
36
40
45
49
50
0.5±0.05(Metal mask)
1±0.05
1.8±0.1
1.8±0.1
Recommended metal mask thickness : 0.15mm
Unit: mm
Dimension
No.1 contact
A±0.1
0.8±0.1(Land)
0.65±0.05(Metal mask)
0.6±0.1(Land) 0.5±0.05
0.5±0.05(Metal mask) 1±0.05
1±0.05
1±0.05
B±0.05
*Set the stiffener thickness to 0.188 (7.5mil) min.
0.5mm Pitch
Vertical
Mounting Type
1.5±0.1
1.5±0.1
4.5±0.1
0.5±0.05
0.3±0.03(FFC)
A±0.05
B±0.07
Odd contact number
No.1 contact
A±0.1
0.8±0.1(Land)
0.65±0.05(Metal mask)
1.8±0.1
1.8±0.1
2MIN
3MIN
Even contact number
1.5±0.1
Number
of Contacts
Dimension
1.5±0.1
4.5±0.1
Dimension
0.5mm Pitch
Top Contact
Type
C
1.3±0.1
A±0.05
B±0.07
B±0.1
C±0.1
1.5±0.1
4.5MIN
3.5MIN
0.35±0.03(FPC)
0.3±0.03(FFC)
0.5±0.05
0.5±0.1
0.5mm Pitch
Bottom Contact
Type
Land / Metal Mask dimensions
2.2±0.1
FPC/FFC dimensions
A
B
12.5
14.5
15.5
16.0
16.5
17.5
19.5
22.0
24.0
24.5
13.5
15.5
16.5
17.0
17.5
18.5
20.5
23.0
25.0
25.5
Unit: mm
Dimension
Number
of Contacts
10
12
13
15
16
17
18
20
22
24
A
B
06.5
07.5
08.0
09.0
09.5
10.0
10.5
11.5
12.5
13.5
04.5
05.5
06.0
07.0
07.5
08.0
08.5
09.5
10.5
11.5
Dimension
Number
of Contacts
26
30
32
33
34
36
40
45
49
50
A
B
14.5
16.5
17.5
18.0
18.5
19.5
21.5
24.0
26.0
26.5
12.5
14.5
15.5
16.0
16.5
17.5
19.5
22.0
24.0
24.5
17
■1mm Pitch Type Bottom Contact Type
2.3
E
A
1.0
(0.2)
1.2
2
0.8
Mated Cross-sectional Diagram
FPC/FFC Contact Surface
(2.1)
(3.1)
2
(4.8)
1.85
B
C
D
4.6
5.6
Unit:mm
Standard type
Part Number
Eccentric type
CL No.
Number of Contacts
A
B
C
D
E
FH12-05S-1SH
586-0591-6
5
04
08.6
09.6
06.07
2.3
FH12-06S-1SH
586-0607-4
6
05
09.6
10.6
07.07
2.3
FH12-07S-1SH
586-0535-5
7
06
10.6
11.6
08.07
2.3
FH12-08S-1SH
586-0579-0
8
07
11.6
12.6
09.07
2.3
FH12-09S-1SH
586-0540-5
9
08
12.6
13.6
10.07
2.3
FH12-11S-1SH
586-0668-9
11
10
14.6
15.6
12.07
2.3
FH12-16S-1SH
586-0536-8
16
15
19.6
20.6
17.07
2.3
FH12-22S-1SH
586-0547-4
22
21
25.6
26.6
23.07
2.3
FH12-26S-1SH
586-0592-9
26
25
29.6
30.6
27.07
2.3
FH12-10(4)SA-1SH
586-0537-0
4
03
08.1
09.1
05.57
2.8
FH12-14(6)SA-1SH
586-0538-3
6
05
10.1
11.1
07.57
2.8
FH12-18(8)SA-1SH
586-0539-6
8
07
12.1
13.1
09.57
2.8
FH12-22(10)SA-1SH
586-0541-8
10
09
14.1
15.1
11.57
2.8
FH12-24(11)SA-1SH
586-0542-0
11
10
15.1
16.1
12.57
2.8
FH12-30(14)SA-1SH
586-0543-3
14
13
18.1
19.1
15.57
2.8
FH12-40(19)SA-1SH
586-0546-1
19
18
23.1
24.1
20.57
2.8
FH12-50(24)SA-1SH
586-0548-7
24
23
28.1
29.1
25.57
2.8
Note 1: Embossed tape reel packaging (2,000 pieces/reel).
Order by number of reels.
Note 2: The 1mm version of FH12 is constructed by loading every other contact into the 0.5mm housing.
When a housing designed for an odd number of 0.5mm pitch contacts is used; the spacing from the
edge to the first contact on either side is the same as the distance between each contact, 1.0mm.
Hirose considers this design to be a standard-type 1.0mm connector.
Note 2: An eccentric-type connector using a housing designed for an even number of 0.5mm pitch contacts
and consequently one side has 1.5mm distance from the edge to the first contact. (See FPC/FFC
dimensional drawing on page 19) The part number for the eccentric type describes the size of the
0.5mm housing used and lists the number of 1.0mm pitch contacts in parentheses () as shown in the
above table.
18
(1.3)
■1mm Pitch Vertical Mounting Type
Mated Cross-sectional Diagram
2
FPC/FFC Contact Surface
(0.15)
(1.4)
(2.15)
(0.2)
2
0.5
F
2.5
0.5
(4.25)
(1.75)
3.6
5.5
(4.85)
A
B
1.0
3.8(Metal fitting dimension)
C
D
E
Unit:mm
Part Number
CL No.
Number of Contacts
A
B
C
D
E
F
FH12-06S-1SV
586-0605-9
6
09.9
08.4
05
08
09.7
4
FH12-07S-1SV
586-0610-9
7
10.9
09.4
06
09
10.7
4
FH12-08S-1SV
586-0593-1
8
11.9
10.4
07
10
11.7
4
FH12-16S-1SV
586-0574-7
16
19.9
18.4
15
18
19.7
8
FH12-20S-1SV
586-0634-7
20
23.9
22.4
19
22
23.7
8
FH12-22S-1SV
586-0584-0
22
25.9
24.4
21
24
25.7
8
FH12-24S-1SV
586-0594-4
24
27.9
26.4
23
26
27.7
8
Note: Embossed tape reel packaging (1,000 pieces/reel).
Order by number of reels.
19
BRecommended FPC/FFC dimensions and Land/Metal Mask dimensions
●1mm Pitch Product
FPC/FFC dimensions
Land / Metal Mask dimensions
Recommended metal mask thickness : 0.15mm
πSet the stiffener thickness to 0.188 (7.5mil) min.
1mm Pitch
Bottom Contact
Type
1mm Pitch
Vertical
Mounting Type
C
5
6
7
8
9
11
16
22
26
04
05
06
07
08
10
15
21
25
06
07
08
09
10
12
17
23
27
1
1
1
1
1
1
1
1
1
A
B
C
4
6
8
10
11
14
19
24
03
05
07
09
10
13
18
23
05.5
07.5
09.5
11.5
12.5
15.5
20.5
25.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
*Set the stiffener thickness to 0.188 (7.5mil) min.
5
6
7
8
9
11
16
22
26
04
05
06
07
08
10
15
21
25
B
C
D
10.6
11.6
12.6
13.6
14.6
16.6
21.6
27.6
31.6
07
08
09
10
11
13
18
24
28
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
20
Number
of Contacts
A
B
6
7
8
16
20
22
24
05
06
07
15
19
21
23
07
08
09
17
21
23
25
03
05
07
09
10
13
18
23
4
6
8
10
11
14
19
24
B
Unit: mm
Dimension
Number
of Contacts
A
B
6
7
8
16
20
22
24
08
09
10
18
22
24
26
05
06
07
15
19
21
23
C
10.1 06.5
12.1 08.5
14.1 10.5
16.1 12.5
17.1 13.5
20.1 16.5
25.1 21.5
30.1 26.5
Recommended metal mask thickness : : 0.15mm
Unit: mm
Dimension
Dimension
A
Number
of Contacts
Eccentric Type
B
Unit: mm
Dimension
A
Number
of Contacts
Standard Type
A
Dimension
Number
of Contacts
Eccentric Type
Standard Type
Unit: mm
Dimension
Number
of Contacts
D
2
2
2
2
2
2
2
2
BPackaging Specification
Embossed Carrier Tape Dimensions
Horizontal Type (Common to Bottom/Top Contact, 0.5mm/1mm Pitch)
Flat surface for placement
with Automatic equipment
(2.0)
●0.5mm Pitch Bottom/Top Contact Type
Dimension
Number
of Contacts
A
B
C
Unit:mm
D
Dimension
Number
of Contacts
A
B
C
D
6
16
----------
07.5
16.5
25
24
----------
11.5
24.5
10
16
----------
07.5
16.5
26
24
----------
11.5
24.5
11
16
----------
07.5
16.5
28
32
28.4
14.2
32.5
12
24
----------
11.5
24.5
29
32
28.4
14.2
32.5
13
24
----------
11.5
24.5
30
32
28.4
14.2
32.5
14
24
----------
11.5
24.5
32
32
28.4
14.2
32.5
15
24
----------
11.5
24.5
33
32
28.4
14.2
32.5
16
24
----------
11.5
24.5
34
32
28.4
14.2
32.5
17
24
----------
11.5
24.5
36
44
40.4
20.2
44.5
18
24
----------
11.5
24.5
40
44
40.4
20.2
44.5
19
24
----------
11.5
24.5
42
44
40.4
20.2
44.5
20
24
----------
11.5
24.5
45
44
40.4
20.2
44.5
22
24
----------
11.5
24.5
50
44
40.4
20.2
44.5
24
24
----------
11.5
24.5
53
44
40.4
20.2
44.5
Note: 2,000 pieces per reel.
Unit:mm
Dimension
Number
of Contacts
A
B
C
D
Dimension
Number
of Contacts
A
B
C
D
5
16
----------
07.5
16.5
4
16
----------
07.5
16.5
6
24
----------
11.5
24.5
6
24
----------
11.5
24.5
7
24
----------
11.5
24.5
8
24
----------
11.5
24.5
8
24
----------
11.5
24.5
10
24
----------
11.5
24.5
9
24
----------
11.5
24.5
11
24
----------
11.5
24.5
11
24
----------
11.5
24.5
14
32
28.4
14.2
32.5
16
32
28.4
14.2
32.5
19
44
40.4
20.2
44.5
22
44
40.4
20.2
44.5
24
44
40.4
20.2
44.5
26
44
40.4
20.2
44.5
Eccentric Type
Standard Type
● 1mm Pitch Bottom Contact Type
Note: 2,000 pieces per reel.
21
Vertical Mounting Type (Common to 0.5mm/1mm Pitch)
Flat surface for placement
with Automatic equipment
(1.75)
●0.5mm Pitch Vertical mounting Type
Dimension
Number
of Contacts
A
B
C
10
16
----------
12
16
----------
13
24
15
24
16
17
D
A
B
C
D
07.5
16.5
26
24
----------
11.5
24.5
07.5
16.5
30
32
28.4
14.2
32.5
----------
11.5
24.5
32
32
28.4
14.2
32.5
----------
11.5
24.5
33
32
28.4
14.2
32.5
24
----------
11.5
24.5
34
44
40.4
20.2
44.5
24
----------
11.5
24.5
36
44
40.4
20.2
44.5
18
24
----------
11.5
24.5
40
44
40.4
20.2
44.5
20
24
----------
11.5
24.5
45
44
40.4
20.2
44.5
22
24
----------
11.5
24.5
49
44
40.4
20.2
44.5
24
24
----------
11.5
24.5
50
44
40.4
20.2
44.5
Note: 1,000 pieces per reel.
●1mm Pitch Vertical mounting Type
Unit:mm
Dimension
Number
of Contacts
A
B
C
D
6
24
----------
11.5
24.5
7
24
----------
11.5
24.5
8
24
----------
11.5
24.5
16
32
28.4
14.2
32.5
20
44
40.4
20.2
44.5
22
44
40.4
20.2
44.5
24
44
40.4
20.2
44.5
Note: 1,000 pieces per reel.
22
Unit:mm
Dimension
Number
of Contacts
Reel Dimensions (Common to All Types)
End portion
Mounting portion
Blank portion
Embossed carrier tape
(10 pockets min.)
Lead portion (400mm min.)
Blank portion
Top cover tape
(10 pockets min.)
BRecommended Temperature Profile
HRS test conditions
Solder method
:Reflow, IR/hot air
(Nihon Den-netsu Co., Ltd.’s
Environment:
Part Number: SENSBY NR-2)
:Room air
Solder composition
:Paste, 63%Sn/37%Pb
(Senju Metal Industry, Co., Ltd.’s
Part Number: OZ63-201C-50-9)
Test board
Land dimensions
:Glass epoxy 40mm∞80mm∞1.6mm thick
:Top and bottom
contact type 0.3mm∞1.3mm
Metal mask
Vertical mounting type 0.6mm∞1.5mm
:Top and bottom contact type
0.25mm∞1.3mm∞0.15mm thick
Vertical mounting type
0.25mm∞1.5mm∞0.15mm thick
This temperature profile is based on the above conditions.
In individual applications the actual temperature may vary,
depending on solder paste type, volume/thickness and board
size/thickness. Consult your solder paste and equipment
manufacturer for specific recommendations.
23
BFH12 Series FPC/FFC Construction (Recommended Specifications)
1. FFC
FFC : Flexible Flat Cable
Material Name
Material
Thickness (µm)
Hard copper foil with tin plating
Adhesive
35
Polyester type
30
Polyester
12
Adhesive
Polyester type
Stiffener
Polyester type
188 (Note)
Total
295
30
*Real tolerance of thickness dimension is on the order of ±20 µm (275 to 315 µm)
Note: Use of a thicker FFC results in a stiffer lock action and the lock is more easily released.
A factor that contributes to thicker FFC is the use of 250 µm stiffener which is thicker than the standard (188 µm) product. This
results in a total thickness of 357 µm.
When using FFC, control of FFC thickness becomes easy if you indicate to us the thickness of the stiffener.
2. FPC
FPC : Flexible Printed Circuit
Material Name
Covering layer film
Material
Thickness (µm)
Polyamide 1 mil
25
25
Cover adhesive
Surface treatment
Tin-lead
Copper foil
Cu
5
1oz
Base film
Polyamide 1 mil
Reinforcement material adhesive Heat-hardened adhesive
Stiffener
25
30
Polyamide 7 mil
175
Total
295
3. Precautions
1. This specification is a recommendation for the construction of the FH12 Series FPC and FFC (t=0.3 ±0.05).
2. For details about the construction, please contact the FPC/FFC manufacturers.
24
35
25
Base adhesive