0.5mm and 1mm Pitch Connectors For FPC/FFC FH12 Series Flip-lock ■Features 1. Ease of Use and Space Savings Only one finger or 6.9N (Newtons) of force is required to lock Hirose’s rotational actuator (flip-lock) as compared to using 2 fingers and 39.2N to close a FFC/FPC connector from our competition. Rotating One-touch Mechanism q The Flip-Lock design also allows customers to place 2 or more connectors side by side as there is no need to waste additional board space for a side latch. 2. Strengthened Flip-lock Actuator The standard Flip-Lock requires only 2.0mm height above the board. A strengthened lock lever is available which only requires an additional 0.4mm. w 3. Supports Thin FPC (0.18mm) Hirose does not require double-sided FPC to have any additional strengthening plate or stiffener and can therefore support a thickness of as little as 0.18mm +/- 0.05. 4. Hirose Ensures Reliability Hirose’s patented half tuning fork contacts maintain the required normal force without relying on the connector housing. With our competitor’s conventional products the housing walls support the contact force, which does not provide for long-term reliability. 5. Prevention of Solder Bridge Excess solder cavity absorbs excessive solder and avoids solder bridging. 6. Three different assembly types FH12 is offered in Top & Bottom Contact and Vertical Mount and offered in both a 0.5mm contact pitch as well as a 1.0mm contact pitch (bottom contact only). ■Applications Notebook computers, printers, PDAs, digital cameras and other compact devices for interconnecting the main circuit board with the LCD, HDD or other device. 6 e ■Product Specifications Current rating: 0.4A DC Operating Temperature Range:_40 to +70ç (Note 1) Storage Temperature Range:_10 to +50ç (Note 2) Rating Voltage rating: 50V AC Operating Humidity Range:Relative humidity, 90% max. Storage Humidity Range:Relative humidity, 90% max. (Not dewed) Applicable FPC t=0.3±0.05 Tin-lead plating(Note 3) (Not dewed) t=0.18 ± 0.05 for FH12F-*S-0.5SH Item 1. Insulation resistance 2. Withstanding voltage 3. Contact resistance Specification 500M ohms minimum No flashover or insulation breakdown. 50m ohms maximum Conditions 4. Durability (Insertion/withdrawal) Contact resistance: 50m ohms maximum No damage, cracks, or parts dislocation. 20 cycles 5. Vibration No electrical discontinuity of 1µs or more Contact resistance: 50m ohms maximum. No damage, cracks, or parts dislocation. Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 directions. 6. Shock No electrical discontinuity of 1µs or more Contact resistance: 50m ohms maximum. No damage, cracks, or parts dislocation. Acceleration of 490 m/s2, 11 ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis. 100V DC 150V AC/1 minute 1mA Contact resistance: 50m ohms maximum. 7. Humidity(Steady state) Insulation resistance: 50M ohms minimum. No damage, cracks, or parts dislocation. 8. Temperature Cycle 96 hours at temperature of 40ç and humidity of 90% to 95% Contact resistance: 50m ohms maximum. Insulation resistance: 50M ohms minimum. No damage, cracks, or parts dislocation. 5 cycles under conditions as follows; Temperature: -40ç / 15 to 35ç / 85ç / 15 to 35ç, Time: 30 / 5 max. / 30 / 5 max.(minutes) No deformation of Reflow: At the recommended temperature profile Manual soldering: 350±5ç for 3 seconds components affecting performance. Note 1: Includes temperature rise caused by current flow. Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and Humidity range covers nonconducting condition of installed connectors in storage, shipment or during transportation. Note 3: When FPC is gold plated, the connector contacts should be also gold plated: Select the (05) specification. 9.Resistance to Soldering heat ■Material Part Material Polyamide PPS Phosphor bronze Brass Insulator Contact Macal Fittings Finish Color : Beige Color : Dark brown Tin-lead plating Tin-lead plating Remarks UL94V-0 ––––––– ■Ordering Information FH12 q A - 10 (4) - S A - 0.5 SH (05) w e r q Series Name : FH12 w Blank : standard type A : Top contact type S : Type with strengthed flip-lock actuator F : Type with 0.18mm FPC End Thickness e Standard type : Number of contacts Eccentric type : Number of contacts in 0.5mm housing r Standard type : Blank Eccentric type : Number of contacts t y u i o t Contact alignment: Single y Eccentric direction: Blank : standard type A : Eccentric type u Contacts Pitch : 0.5mm, 1mm i Contact type SH : SMT horizontal mounting type SV : SMT vertical mounting type o Plating specification Blank : Tin-lead plating (05) : Gold plating 7 BSeries Configuration Pitch Bottom Contact Type Top Contact Type Vertical mounting Type FPC conductive surface (bottom side) FPC conductive surface FH12- ** S-0.5SH P.12 Number of contacts 6, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 0.5mm 22, 24, 25, 26, 28, 30, 32, 33, 34, 36, 40, 45, 50, 53 Type with Strengthened Lock Lever FH12S- ** S-0.5SH P.13 Number of contacts 30, 40, 45, 50, 53 Type with 0.18mm FPC End Thickness FH12A- ** S-0.5SH FH12F- ** S-0.5SH P.14 Number of contacts 6, 10, 12, 13, 14, 15, 16, 18, 20, 22, 24, 26, 28, 30, 32, (33), 34, 36, 40 P.15 Number of contacts 10, 12 ,15, 16, 18, 20, 22, 24, 26, 28, 29, 30, 32, 33, 34, 36, 40, 42, 45, 50 FH12- ** S-0.5SV P.16 Number of contacts 10, 12, 13, 15, 16, 17, 18, 20, 22, 24, 26, 30, 32, 33, 34, 36, 40, 45, 49, 50 FPC conductive surface (bottom side) 1mm Standard FH12- ** S-1SH P.18 Eccentric FH12- ** (**) S-1SH Standard Number of contacts 5, 6, 7, 8, 9, 11, 16, 22, 26 Eccentric FH12- ** S-1SV Number of contacts 6, 7, 8, 16, 20, 22, Number of contacts 4, 6, 8, 10, 11, 14, 19, 24 8 P.19 24 BConnector Operating Instructions, precautions and recommendations ●Bottom Contact Type (common for 0.5mm/1mm) Operation Precautions 1. FPC/FFC Termination procedure. Connector installed on the board. 1) Avoid grasping the actuator with two fingers or lifting the actuator with fingernail. 1) Lift up the actuator. Use thumb or index finger. 2) Rotate down the actuator until firmly closed. It is critical that the inserted FPC/FFC is not moved and remains fully inserted. Should the FPC/FFC be moved, open the actuator and repeat the process, starting with Step 1 above. 2) Fully insert the FPC/FFC parallel to mounting surface, with the exposed conductive traces facing down. Stiffener FPC/FFC conductive traces 2. FPC/FFC Removal 1) Lift up the actuator. 2) Carefully remove the FPC/FFC. 3) Due to the structure of the connectors, they do not have strong resistance to upward pulling; therefore, support the FPC/FFC when a pulling force is applied to it. 9 ●Top Contact Type Operation Precautions 1. FPC/FFC Termination procedure. Connector installed on the board. 1) Avoid forcing the actuator up or down without the FPC/FFC inserted. 1) Lift up the actuator. Use thumb or index finger. 2) Fully insert the FPC/FFC parallel to mounting surface, with the exposed conductive traces facing UP. a are ion t r nse Ci FP FPC/FFC conductive traces 2) When closing down the actuator apply equal pressure to both sides of the actuator. Stiffener 3) Rotate down the actuator until firmly closed. It is critical that the inserted FPC/FFC is not moved and remains fully inserted. Should the FPC/FFC be moved, open the actuator and repeat the process, starting with Step 1 above. 3) Avoid forced pulling of the FPC. Forced pulling will cause the FPC to become disconnected or damaged. 2. FPC/FFC Removal 1) Lift up the actuator. 2) Carefully remove the FPC/FFC. 10 ●Vertical Mounting Type Operation 1. FPC/FFC Termination procedure. Connector installed on the board. Precautions 1) Avoid forcing the actuator up or down without the FPC/FFC inserted. 1) Verify that the actuator is positioned upright. If the actuator has rotated to the side, carefully rotate it upright. Actuator upright 2) Insert the FPC/FFC vertically in the connector slot assuring that the conductive traces of the FPC/FFC are facing away from the actuator. Stiffener FPC/FFC conductive traces Sl ot 3) Press down the actuator in the direction shown. 2. FPC/FFC Removal Rotate the actuator upward and withdraw the FPC/FFC. 11 ■0.5mm Pitch Bottom Contact Type A 0.5 ( 0.2) 1.2 2 0.8 Mated Cross-sectional Diagram FPC/FFC Contact Surface (2.1) (3.1) 2 (4.8) 2 1.85 B C D Unit:mm Note 2 Part Number CL No. Number of Contacts A B C D FH12-06S-0.5SH 586-0582-5 6 02.5 06.1 07.1 03.57 FH12-10S-0.5SH 586-0522-3 10 04.5 08.1 09.1 05.57 FH12-11S-0.5SH 586-0600-5 11 05.0 08.6 09.6 06.07 FH12-12S-0.5SH 586-0704-0 12 05.5 09.1 10.1 06.57 FH12-13S-0.5SH 586-0549-0 13 06.0 09.6 10.6 07.07 FH12-14S-0.5SH 586-0533-0 14 06.5 10.1 11.1 07.57 FH12-15S-0.5SH 586-0523-6 15 07.0 10.6 11.6 08.07 FH12-16S-0.5SH 586-0531-4 16 07.5 11.1 12.1 08.57 FH12-17S-0.5SH 586-0606-1 17 08.0 11.6 12.6 09.07 FH12-18S-0.5SH 586-0530-1 18 08.5 12.1 13.1 09.57 FH12-19S-0.5SH 586-0534-2 19 09.0 12.6 13.6 10.07 FH12-20S-0.5SH 586-0524-9 20 09.5 13.1 14.1 10.57 FH12-22S-0.5SH 586-0532-7 22 10.5 14.1 15.1 11.57 FH12-24S-0.5SH 586-0521-0 24 11.5 15.1 16.1 12.57 FH12-25S-0.5SH 586-0692-3 25 12.0 15.6 16.6 13.07 FH12-26S-0.5SH 586-0576-2 26 12.5 16.1 17.1 13.57 FH12-28S-0.5SH 586-0612-4 28 13.5 17.1 18.1 14.57 FH12-30S-0.5SH 586-0525-1 30 14.5 18.1 19.1 15.57 FH12-32S-0.5SH 586-0681-7 32 15.5 19.1 20.1 16.57 FH12-33S-0.5SH 586-0520-8 33 16.0 19.6 20.6 17.07 FH12-34S-0.5SH 586-0617-8 34 16.5 20.1 21.1 17.57 FH12-36S-0.5SH 586-0526-4 36 17.5 21.1 22.1 18.57 Note 2 FH12-40S-0.5SH 586-0527-7 40 19.5 23.1 24.1 20.57 Note 2 FH12-45S-0.5SH 586-0528-0 45 22.0 25.6 26.6 23.07 Note 2 FH12-50S-0.5SH 586-0529-2 50 24.5 28.1 29.1 25.57 FH12-53S-0.5SH 586-0595-7 53 26.0 29.6 30.6 27.07 Note 2 Note 1 : Embossed tape reel packaging (2,000 pieces/reel). Order by number of reels. Note 2 : If there is no problem with the connector height, we recommend the type with the strengthened Flip-lock actuator (FH12S-*S-0.5SH). Standard type connector height: 2 mm Connector height of type with strengthened Flip-lock actuator: 2.4 mm 12 4.6 5.6 (1.3) ■0.5mm Pitch Bottom Contact Type with Strengthened Flip-lock Actuator Mated Cross-sectional Diagram 1.2 2 0.8 A 0.5 ( 0.2 ) FPC/FFC Contact Surface ( 2.1) ( 3.1 ) ( 1.3 ) 2.25 D 2 2.4 ( 4.8 ) B C 4.6 5.6 Unit:mm Part Number CL No. Number of Contacts A B C D FH12S-30S-0.5SH 586-0667-6 30 14.5 18.1 19.1 15.57 FH12S-40S-0.5SH 586-0640-0 40 19.5 23.1 24.1 20.57 FH12S-45S-0.5SH 586-0665-0 45 22.0 25.6 26.6 23.07 FH12S-50S-0.5SH 586-0642-5 50 24.5 28.1 29.1 25.57 FH12S-53S-0.5SH 586-0691-0 53 26.0 29.6 30.6 27.07 Note: Embossed tape reel packaging (2,000 pieces/reel). Order by number of reels. 13 ■0.5mm Pitch Bottom Contact Type with 0.18mm FPC End Thickness Applicable FPC end thickness : 0.18±0.05 A 0.5 ( 0.2 ) 1.2 2 0.8 Mated Cross-sectional Diagram FPC Contact Surface (2.15) (3.15) 2 ( 4.8 ) 1.85 B C D 4.6 5.6 Unit:mm Part Number CL No. Number of Contacts A B C D FH12F-06S-0.5SH 586-0672-6 6 02.5 06.1 07.1 03.57 FH12F-10S-0.5SH 586-0709-4 10 04.5 08.1 09.1 05.57 FH12F-12S-0.5SH 586-0653-1 12 05.5 09.1 10.1 06.57 FH12F-13S-0.5SH 586-0629-7 13 06.0 09.6 10.6 07.07 FH12F-14S-0.5SH 586-0655-7 14 06.5 10.1 11.1 07.57 FH12F-15S-0.5SH 586-0680-4 15 07.0 10.6 11.6 08.07 FH12F-16S-0.5SH 586-0673-9 16 07.5 11.1 12.1 08.57 FH12F-18S-0.5SH 586-0626-9 18 08.5 12.1 13.1 09.57 FH12F-20S-0.5SH 586-0636-2 20 09.5 13.1 14.1 10.57 FH12F-22S-0.5SH 586-0630-6 22 10.5 14.1 15.1 11.57 FH12F-24S-0.5SH 586-0632-1 24 11.5 15.1 16.1 12.57 FH12F-26S-0.5SH 586-0627-1 26 12.5 16.1 17.1 13.57 FH12F-28S-0.5SH 586-0643-8 28 13.5 17.1 18.1 14.57 FH12F-30S-0.5SH 586-0628-4 30 14.5 18.1 19.1 15.57 FH12F-32S-0.5SH 586-0705-3 32 15.5 19.1 20.1 16.57 FH12F-33S-0.5SH -------------------- 33 16.0 19.6 20.6 17.07 FH12F-34S-0.5SH 586-0677-0 34 16.5 20.1 21.1 17.57 FH12F-36S-0.5SH 586-0656-0 36 17.5 21.1 22.1 18.57 FH12F-40S-0.5SH 586-0635-0 40 19.5 23.1 24.1 20.57 Note: Embossed tape reel packaging (2,000 pieces/reel). Order by number of reels. 14 (1.25) ■0.5mm Pitch Top Contact Type A B C Mated Cross-sectional Diagram 0.5 (0.2) (1.9) FPC/FFC Contact Surface (1.45) (1.85) 2 (5) 6.2 2 (3.6) D E (0.45) 0.8 2.2 0.85 1.45 Unit:mm Part Number CL No. Number of Contacts A B C D E FH12A-10S-0.5SH 586-0550-9 10 9.1 8.35 4.5 9.5 5.57 FH12A-12S-0.5SH 586-0696-4 12 10.1 9.35 5.5 10.5 6.57 FH12A-15S-0.5SH 586-0551-1 15 11.6 10.85 7.0 12.0 8.07 FH12A-16S-0.5SH 586-0552-4 16 12.1 11.35 7.5 12.5 8.57 FH12A-18S-0.5SH 586-0553-7 18 13.1 12.35 8.5 13.5 9.57 FH12A-20S-0.5SH 586-0554-0 20 14.1 13.35 9.5 14.5 10.57 FH12A-22S-0.5SH 586-0686-0 22 15.1 14.35 10.5 15.5 11.57 FH12A-24S-0.5SH 586-0555-2 24 16.1 15.35 11.5 16.5 12.57 FH12A-26S-0.5SH 586-0663-5 26 17.1 16.35 12.5 17.5 13.57 FH12A-28S-0.5SH 586-0725-0 28 18.1 17.35 13.5 18.5 14.57 FH12A-29S-0.5SH 586-0585-3 29 18.6 17.85 14.0 19.0 15.07 FH12A-30S-0.5SH 586-0556-5 30 19.1 18.35 14.5 19.5 15.57 FH12A-32S-0.5SH 586-0687-3 32 20.1 19.35 15.5 20.5 16.57 FH12A-33S-0.5SH 586-0570-6 33 20.6 19.85 16.0 21.0 17.07 FH12A-34S-0.5SH 586-0670-0 34 21.1 20.35 16.5 21.5 17.57 FH12A-36S-0.5SH 586-0662-2 36 22.1 21.35 17.5 22.5 18.57 FH12A-40S-0.5SH 586-0557-8 40 24.1 23.35 19.5 24.5 20.57 FH12A-42S-0.5SH 586-0698-0 42 25.1 24.35 20.5 25.5 21.57 FH12A-45S-0.5SH 586-0558-0 45 26.6 25.85 22.0 27.0 23.07 FH12A-50S-0.5SH 586-0559-3 50 29.1 28.35 24.5 29.5 25.57 Note 1 : Embossed tape reel packaging (2,000 pieces/reel). Order by number of reels. Note 2 : The design is such that the FPC/FFC protrudes on an upward angle so that other parts can be mounted beneath the PFC/FFC. In view of this, please take note of the gap at the top surface of the connector. 15 ■0.5mm Pitch Vertical mounting Type Mated Cross-sectional Diagram ( 0.2 ) ( 0.15) FPC/FFC Contact Surface (1.4 ) ( 2.15 ) 1 1 0.5 F 2.5 0.5 ( 4.25 ) (1.75 ) 3.6 5.5 ( 4.85 ) A B 0.5 3.8(Metal fitting dimension) C D E Unit:mm Part Number CL No. Number of Contacts A B C D E F FH12-10S-0.5SV 586-0560-2 10 08.4 06.9 04.5 06.5 08.2 4 FH12-12S-0.5SV 586-0615-2 12 09.4 07.9 05.5 07.5 09.2 4 FH12-13S-0.5SV 586-0575-0 13 09.9 08.4 06.0 08.0 09.7 4 FH12-15S-0.5SV 586-0561-5 15 10.9 09.4 07.0 09.0 10.7 4 FH12-16S-0.5SV 586-0572-1 16 11.4 09.9 07.5 09.5 11.2 4 FH12-17S-0.5SV 586-0601-8 17 11.9 10.4 08.0 10.0 11.7 4 FH12-18S-0.5SV 586-0573-4 18 12.4 10.9 08.5 10.5 12.2 4 FH12-20S-0.5SV 586-0562-8 20 13.4 11.9 09.5 11.5 13.2 4 FH12-22S-0.5SV 586-0589-4 22 14.4 12.9 10.5 12.5 14.2 8 FH12-24S-0.5SV 586-0563-0 24 15.4 13.9 11.5 13.5 15.2 8 FH12-26S-0.5SV 586-0664-8 26 16.4 14.9 12.5 14.5 16.2 8 FH12-30S-0.5SV 586-0564-3 30 18.4 16.9 14.5 16.5 18.2 8 FH12-32S-0.5SV 586-0699-2 32 19.4 17.9 15.5 17.5 19.2 8 FH12-33S-0.5SV 586-0565-6 33 19.9 18.4 16.0 18.0 19.7 8 FH12-34S-0.5SV 586-0706-6 34 20.4 18.9 16.5 18.5 20.2 8 FH12-36S-0.5SV 586-0641-2 36 21.4 19.9 17.5 19.5 21.2 8 FH12-40S-0.5SV 586-0566-9 40 23.4 21.9 19.5 21.5 23.2 8 FH12-45S-0.5SV 586-0567-1 45 25.9 24.4 22.0 24.0 25.7 8 FH12-49S-0.5SV 586-0602-0 49 27.9 26.4 24.0 26.0 27.7 8 FH12-50S-0.5SV 586-0568-4 50 28.4 26.9 24.5 26.5 28.2 8 Note 1 : Embossed tape reel packaging (1,000 pieces/reel). Order by number of reels. 16 BRecommended FPC/FFC dimensions and Land/Metal Mask dimensions ●0.5mm Pitch Product Product Type C Dimension Types other than 0.3±0.05min those below Stiffener thickness should be 0.188 mm (7.5 mil) min Types with an FPC end 0.18±0.05 thickness of 0.18 mm 0.3±0.03(Land) 0.5±0.05 0.25±0.03(Metal mask) A±0.05 Recommended metal mask thickness : 0.15mm Unit: mm 6 10 11 12 13 14 15 16 17 18 19 20 22 24 A B 02.5 04.5 05.0 05.5 06.0 06.5 07.0 07.5 08.0 08.5 09.0 09.5 10.5 11.5 03.5 05.5 06.0 06.5 07.0 07.5 08.0 08.5 09.0 09.5 10.0 10.5 11.5 12.5 Number of Contacts 25 26 28 29 30 32 33 34 36 40 42 45 50 53 Unit: mm A B Dimension Number of Contacts 12.0 12.5 13.5 14.0 14.5 15.5 16.0 16.5 17.5 19.5 20.5 22.0 24.5 26.0 13.0 13.5 14.5 15.0 15.5 16.5 17.0 17.5 18.5 20.5 21.5 23.0 25.5 27.0 6 10 11 12 13 14 15 16 17 18 19 20 22 24 A B 02.5 04.5 05.0 05.5 06.0 06.5 07.0 07.5 08.0 08.5 09.0 09.5 10.5 11.5 08.1 10.1 10.6 11.1 11.6 12.1 12.6 13.1 13.6 14.1 14.6 15.1 16.1 17.1 C Dimension Number of Contacts A B C 04.5 06.5 07.0 07.5 08.0 08.5 09.0 09.5 10.0 10.5 11.0 11.5 12.5 13.5 25 26 28 29 30 32 33 34 36 40 42 45 50 53 12.0 12.5 13.5 14.0 14.5 15.5 16.0 16.5 17.5 19.5 20.5 22.0 24.5 26.0 17.6 18.1 19.1 19.6 20.1 21.1 21.6 22.1 23.1 25.1 26.1 27.6 30.1 31.6 14.0 14.5 15.5 16.0 16.5 17.5 18.0 18.5 19.5 21.5 22.5 24.0 26.5 28.0 0.5±0.05 0.5±0.1 0.35±0.03(FPC) 0.3±0.05 1±0.05 1±0.05 0.6±0.1(Land) B±0.05 Number of Contacts 10 12 13 15 16 17 18 20 22 24 A B 04.5 05.5 06.0 07.0 07.5 08.0 08.5 09.5 10.5 11.5 05.5 06.5 07.0 08.0 08.5 09.0 09.5 10.5 11.5 12.5 Dimension Number of Contacts 26 30 32 33 34 36 40 45 49 50 0.5±0.05(Metal mask) 1±0.05 1.8±0.1 1.8±0.1 Recommended metal mask thickness : 0.15mm Unit: mm Dimension No.1 contact A±0.1 0.8±0.1(Land) 0.65±0.05(Metal mask) 0.6±0.1(Land) 0.5±0.05 0.5±0.05(Metal mask) 1±0.05 1±0.05 1±0.05 B±0.05 *Set the stiffener thickness to 0.188 (7.5mil) min. 0.5mm Pitch Vertical Mounting Type 1.5±0.1 1.5±0.1 4.5±0.1 0.5±0.05 0.3±0.03(FFC) A±0.05 B±0.07 Odd contact number No.1 contact A±0.1 0.8±0.1(Land) 0.65±0.05(Metal mask) 1.8±0.1 1.8±0.1 2MIN 3MIN Even contact number 1.5±0.1 Number of Contacts Dimension 1.5±0.1 4.5±0.1 Dimension 0.5mm Pitch Top Contact Type C 1.3±0.1 A±0.05 B±0.07 B±0.1 C±0.1 1.5±0.1 4.5MIN 3.5MIN 0.35±0.03(FPC) 0.3±0.03(FFC) 0.5±0.05 0.5±0.1 0.5mm Pitch Bottom Contact Type Land / Metal Mask dimensions 2.2±0.1 FPC/FFC dimensions A B 12.5 14.5 15.5 16.0 16.5 17.5 19.5 22.0 24.0 24.5 13.5 15.5 16.5 17.0 17.5 18.5 20.5 23.0 25.0 25.5 Unit: mm Dimension Number of Contacts 10 12 13 15 16 17 18 20 22 24 A B 06.5 07.5 08.0 09.0 09.5 10.0 10.5 11.5 12.5 13.5 04.5 05.5 06.0 07.0 07.5 08.0 08.5 09.5 10.5 11.5 Dimension Number of Contacts 26 30 32 33 34 36 40 45 49 50 A B 14.5 16.5 17.5 18.0 18.5 19.5 21.5 24.0 26.0 26.5 12.5 14.5 15.5 16.0 16.5 17.5 19.5 22.0 24.0 24.5 17 ■1mm Pitch Type Bottom Contact Type 2.3 E A 1.0 (0.2) 1.2 2 0.8 Mated Cross-sectional Diagram FPC/FFC Contact Surface (2.1) (3.1) 2 (4.8) 1.85 B C D 4.6 5.6 Unit:mm Standard type Part Number Eccentric type CL No. Number of Contacts A B C D E FH12-05S-1SH 586-0591-6 5 04 08.6 09.6 06.07 2.3 FH12-06S-1SH 586-0607-4 6 05 09.6 10.6 07.07 2.3 FH12-07S-1SH 586-0535-5 7 06 10.6 11.6 08.07 2.3 FH12-08S-1SH 586-0579-0 8 07 11.6 12.6 09.07 2.3 FH12-09S-1SH 586-0540-5 9 08 12.6 13.6 10.07 2.3 FH12-11S-1SH 586-0668-9 11 10 14.6 15.6 12.07 2.3 FH12-16S-1SH 586-0536-8 16 15 19.6 20.6 17.07 2.3 FH12-22S-1SH 586-0547-4 22 21 25.6 26.6 23.07 2.3 FH12-26S-1SH 586-0592-9 26 25 29.6 30.6 27.07 2.3 FH12-10(4)SA-1SH 586-0537-0 4 03 08.1 09.1 05.57 2.8 FH12-14(6)SA-1SH 586-0538-3 6 05 10.1 11.1 07.57 2.8 FH12-18(8)SA-1SH 586-0539-6 8 07 12.1 13.1 09.57 2.8 FH12-22(10)SA-1SH 586-0541-8 10 09 14.1 15.1 11.57 2.8 FH12-24(11)SA-1SH 586-0542-0 11 10 15.1 16.1 12.57 2.8 FH12-30(14)SA-1SH 586-0543-3 14 13 18.1 19.1 15.57 2.8 FH12-40(19)SA-1SH 586-0546-1 19 18 23.1 24.1 20.57 2.8 FH12-50(24)SA-1SH 586-0548-7 24 23 28.1 29.1 25.57 2.8 Note 1: Embossed tape reel packaging (2,000 pieces/reel). Order by number of reels. Note 2: The 1mm version of FH12 is constructed by loading every other contact into the 0.5mm housing. When a housing designed for an odd number of 0.5mm pitch contacts is used; the spacing from the edge to the first contact on either side is the same as the distance between each contact, 1.0mm. Hirose considers this design to be a standard-type 1.0mm connector. Note 2: An eccentric-type connector using a housing designed for an even number of 0.5mm pitch contacts and consequently one side has 1.5mm distance from the edge to the first contact. (See FPC/FFC dimensional drawing on page 19) The part number for the eccentric type describes the size of the 0.5mm housing used and lists the number of 1.0mm pitch contacts in parentheses () as shown in the above table. 18 (1.3) ■1mm Pitch Vertical Mounting Type Mated Cross-sectional Diagram 2 FPC/FFC Contact Surface (0.15) (1.4) (2.15) (0.2) 2 0.5 F 2.5 0.5 (4.25) (1.75) 3.6 5.5 (4.85) A B 1.0 3.8(Metal fitting dimension) C D E Unit:mm Part Number CL No. Number of Contacts A B C D E F FH12-06S-1SV 586-0605-9 6 09.9 08.4 05 08 09.7 4 FH12-07S-1SV 586-0610-9 7 10.9 09.4 06 09 10.7 4 FH12-08S-1SV 586-0593-1 8 11.9 10.4 07 10 11.7 4 FH12-16S-1SV 586-0574-7 16 19.9 18.4 15 18 19.7 8 FH12-20S-1SV 586-0634-7 20 23.9 22.4 19 22 23.7 8 FH12-22S-1SV 586-0584-0 22 25.9 24.4 21 24 25.7 8 FH12-24S-1SV 586-0594-4 24 27.9 26.4 23 26 27.7 8 Note: Embossed tape reel packaging (1,000 pieces/reel). Order by number of reels. 19 BRecommended FPC/FFC dimensions and Land/Metal Mask dimensions ●1mm Pitch Product FPC/FFC dimensions Land / Metal Mask dimensions Recommended metal mask thickness : 0.15mm πSet the stiffener thickness to 0.188 (7.5mil) min. 1mm Pitch Bottom Contact Type 1mm Pitch Vertical Mounting Type C 5 6 7 8 9 11 16 22 26 04 05 06 07 08 10 15 21 25 06 07 08 09 10 12 17 23 27 1 1 1 1 1 1 1 1 1 A B C 4 6 8 10 11 14 19 24 03 05 07 09 10 13 18 23 05.5 07.5 09.5 11.5 12.5 15.5 20.5 25.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 *Set the stiffener thickness to 0.188 (7.5mil) min. 5 6 7 8 9 11 16 22 26 04 05 06 07 08 10 15 21 25 B C D 10.6 11.6 12.6 13.6 14.6 16.6 21.6 27.6 31.6 07 08 09 10 11 13 18 24 28 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 20 Number of Contacts A B 6 7 8 16 20 22 24 05 06 07 15 19 21 23 07 08 09 17 21 23 25 03 05 07 09 10 13 18 23 4 6 8 10 11 14 19 24 B Unit: mm Dimension Number of Contacts A B 6 7 8 16 20 22 24 08 09 10 18 22 24 26 05 06 07 15 19 21 23 C 10.1 06.5 12.1 08.5 14.1 10.5 16.1 12.5 17.1 13.5 20.1 16.5 25.1 21.5 30.1 26.5 Recommended metal mask thickness : : 0.15mm Unit: mm Dimension Dimension A Number of Contacts Eccentric Type B Unit: mm Dimension A Number of Contacts Standard Type A Dimension Number of Contacts Eccentric Type Standard Type Unit: mm Dimension Number of Contacts D 2 2 2 2 2 2 2 2 BPackaging Specification Embossed Carrier Tape Dimensions Horizontal Type (Common to Bottom/Top Contact, 0.5mm/1mm Pitch) Flat surface for placement with Automatic equipment (2.0) ●0.5mm Pitch Bottom/Top Contact Type Dimension Number of Contacts A B C Unit:mm D Dimension Number of Contacts A B C D 6 16 ---------- 07.5 16.5 25 24 ---------- 11.5 24.5 10 16 ---------- 07.5 16.5 26 24 ---------- 11.5 24.5 11 16 ---------- 07.5 16.5 28 32 28.4 14.2 32.5 12 24 ---------- 11.5 24.5 29 32 28.4 14.2 32.5 13 24 ---------- 11.5 24.5 30 32 28.4 14.2 32.5 14 24 ---------- 11.5 24.5 32 32 28.4 14.2 32.5 15 24 ---------- 11.5 24.5 33 32 28.4 14.2 32.5 16 24 ---------- 11.5 24.5 34 32 28.4 14.2 32.5 17 24 ---------- 11.5 24.5 36 44 40.4 20.2 44.5 18 24 ---------- 11.5 24.5 40 44 40.4 20.2 44.5 19 24 ---------- 11.5 24.5 42 44 40.4 20.2 44.5 20 24 ---------- 11.5 24.5 45 44 40.4 20.2 44.5 22 24 ---------- 11.5 24.5 50 44 40.4 20.2 44.5 24 24 ---------- 11.5 24.5 53 44 40.4 20.2 44.5 Note: 2,000 pieces per reel. Unit:mm Dimension Number of Contacts A B C D Dimension Number of Contacts A B C D 5 16 ---------- 07.5 16.5 4 16 ---------- 07.5 16.5 6 24 ---------- 11.5 24.5 6 24 ---------- 11.5 24.5 7 24 ---------- 11.5 24.5 8 24 ---------- 11.5 24.5 8 24 ---------- 11.5 24.5 10 24 ---------- 11.5 24.5 9 24 ---------- 11.5 24.5 11 24 ---------- 11.5 24.5 11 24 ---------- 11.5 24.5 14 32 28.4 14.2 32.5 16 32 28.4 14.2 32.5 19 44 40.4 20.2 44.5 22 44 40.4 20.2 44.5 24 44 40.4 20.2 44.5 26 44 40.4 20.2 44.5 Eccentric Type Standard Type ● 1mm Pitch Bottom Contact Type Note: 2,000 pieces per reel. 21 Vertical Mounting Type (Common to 0.5mm/1mm Pitch) Flat surface for placement with Automatic equipment (1.75) ●0.5mm Pitch Vertical mounting Type Dimension Number of Contacts A B C 10 16 ---------- 12 16 ---------- 13 24 15 24 16 17 D A B C D 07.5 16.5 26 24 ---------- 11.5 24.5 07.5 16.5 30 32 28.4 14.2 32.5 ---------- 11.5 24.5 32 32 28.4 14.2 32.5 ---------- 11.5 24.5 33 32 28.4 14.2 32.5 24 ---------- 11.5 24.5 34 44 40.4 20.2 44.5 24 ---------- 11.5 24.5 36 44 40.4 20.2 44.5 18 24 ---------- 11.5 24.5 40 44 40.4 20.2 44.5 20 24 ---------- 11.5 24.5 45 44 40.4 20.2 44.5 22 24 ---------- 11.5 24.5 49 44 40.4 20.2 44.5 24 24 ---------- 11.5 24.5 50 44 40.4 20.2 44.5 Note: 1,000 pieces per reel. ●1mm Pitch Vertical mounting Type Unit:mm Dimension Number of Contacts A B C D 6 24 ---------- 11.5 24.5 7 24 ---------- 11.5 24.5 8 24 ---------- 11.5 24.5 16 32 28.4 14.2 32.5 20 44 40.4 20.2 44.5 22 44 40.4 20.2 44.5 24 44 40.4 20.2 44.5 Note: 1,000 pieces per reel. 22 Unit:mm Dimension Number of Contacts Reel Dimensions (Common to All Types) End portion Mounting portion Blank portion Embossed carrier tape (10 pockets min.) Lead portion (400mm min.) Blank portion Top cover tape (10 pockets min.) BRecommended Temperature Profile HRS test conditions Solder method :Reflow, IR/hot air (Nihon Den-netsu Co., Ltd.’s Environment: Part Number: SENSBY NR-2) :Room air Solder composition :Paste, 63%Sn/37%Pb (Senju Metal Industry, Co., Ltd.’s Part Number: OZ63-201C-50-9) Test board Land dimensions :Glass epoxy 40mm∞80mm∞1.6mm thick :Top and bottom contact type 0.3mm∞1.3mm Metal mask Vertical mounting type 0.6mm∞1.5mm :Top and bottom contact type 0.25mm∞1.3mm∞0.15mm thick Vertical mounting type 0.25mm∞1.5mm∞0.15mm thick This temperature profile is based on the above conditions. In individual applications the actual temperature may vary, depending on solder paste type, volume/thickness and board size/thickness. Consult your solder paste and equipment manufacturer for specific recommendations. 23 BFH12 Series FPC/FFC Construction (Recommended Specifications) 1. FFC FFC : Flexible Flat Cable Material Name Material Thickness (µm) Hard copper foil with tin plating Adhesive 35 Polyester type 30 Polyester 12 Adhesive Polyester type Stiffener Polyester type 188 (Note) Total 295 30 *Real tolerance of thickness dimension is on the order of ±20 µm (275 to 315 µm) Note: Use of a thicker FFC results in a stiffer lock action and the lock is more easily released. A factor that contributes to thicker FFC is the use of 250 µm stiffener which is thicker than the standard (188 µm) product. This results in a total thickness of 357 µm. When using FFC, control of FFC thickness becomes easy if you indicate to us the thickness of the stiffener. 2. FPC FPC : Flexible Printed Circuit Material Name Covering layer film Material Thickness (µm) Polyamide 1 mil 25 25 Cover adhesive Surface treatment Tin-lead Copper foil Cu 5 1oz Base film Polyamide 1 mil Reinforcement material adhesive Heat-hardened adhesive Stiffener 25 30 Polyamide 7 mil 175 Total 295 3. Precautions 1. This specification is a recommendation for the construction of the FH12 Series FPC and FFC (t=0.3 ±0.05). 2. For details about the construction, please contact the FPC/FFC manufacturers. 24 35 25 Base adhesive