VISHAY UGF10FCT

NEW PRODUCT
NEW PRODUCT
NEW PRODUCT
UGF10FCT AND UGF10GCT
ULTRAFAST SOFT RECOVERY RECTIFIER
Reverse Voltage - 300 to 400 Volts
Forward Current - 10.0 Amperes
FEATURES
ITO-220AB
0.188 (4.77)
0.172 (4.36)
0.405 (10.27)
0.383 (9.72)
0.110 (2.80)
0.100 (2.54)
0.131 (3.39)
DIA.
0.122 (3.08)
0.140 (3.56)
DIA.
0.130 (3.30)
0.600 (15.5)
0.580 (14.5)
0.670 (17.2)
0.646 (16.4)
PIN
1
2
3
0.350 (8.89)
0.330 (8.38)
0.191 (4.85)
0.171 (4.35)
0.560 (14.22)
0.530 (13.46)
0.110 (2.80)
0.100 (2.54)
0.060 (1.52)
0.037 (0.94)
0.027 (0.69)
0.205 (5.20)
0.195 (4.95)
0.105 (2.67)
0.095 (2.41)
0.022 (0.55)
0.014 (0.36)
PIN 1
PIN 2
PIN 3
♦ Plastic package has Underwriters Laboratories
Flammability Classification 94V-0
♦ Ideally suited for free wheeling diode power factor
correction applications
♦ Soft recovery characteristics
♦ Excellent high temperature switching
♦ Optimized to reduce switching losses
♦ High temperature soldering guaranteed:
250°C, 0.25" (6.35mm) from case for 10 seconds
♦ Glass passivated chip junction
MECHANICAL DATA
Case: ITO-220AB molded plastic body
Terminals: Plated leads, solderable per MIL-STD-750,
Method 2026
Polarity: As marked
Mounting Position: Any
Weight: 0.08 ounce, 2.24 grams
Mounting Torque: 5 in. - lbs. max.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
UGF10FCT
UGF10GCT
UNITS
Maximum repetitive peak reverse voltage
Working peak reverse voltage
VRRM
VRWM
300
225
400
300
Volts
Volts
Maximum RMS voltage
VRMS
210
280
Volts
Maximum DC blocking voltage
VDC
300
400
Volts
Maximum average forward rectified current at TC=100°C
I(AV)
10
Amps
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method) per leg
IFSM
60A
Amps
Maximum instantaneous forward voltage per leg
IF= 5A
Maximum reverse leakage current
at working peak reverse voltage
TJ=25°C
TJ=150°C
TJ=25°C
TJ=100°C
Maximum reverse recovery time per leg at IF=0.5A, IR=1.0A, Irr=0.25A
Maximum Reverse recovery time per leg at
IF=1.0A, di/dt=100A/µs, VR=30V, Irr=0.1 IRM
Maximum reverse recovery current per leg at
IF=5A, di/dt=50A/µs,VR=30V
Maximum stored charge per leg
IF=2A, di/dt=20A/µs, VR=30V, Irr=0.1 IRM
Typical thermal resistance from junction to case per leg
Operating junction and storage temperature range
4/98
TC=100°C
VF
IR
1.30
1.05
10
200
Volts
µA
trr
35
ns
trr
50
ns
IRM
3.0
Amps
Qrr
50
nC
RΘJC
TJ, TSTG
6.0
-40 to +150
°C/W
°C
RATINGS AND CHARACTERISTIC CURVES UGF10FCT AND UGF10GCT
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT PER LEG
15
100
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
TC=105°C
RESISTIVE OR INDUCTIVE LOAD
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD CURRENT, AMPERES
FIG. 1 -FORWARD CURRENT DERATING CURVE
10
5
0
10
1
25
0
50
100
75
125
150
NUMBER OF CYCLES AT 60 HZ
CASE TEMPERATURE, °C
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
PER LEG
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
1,000
INSTANTANEOUS REVERSE LEAKAGE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
100
10
TJ=125°C
1
TJ=100°C
0.1
TJ=25°C
TJ=125°C
100
TJ=100°C
10
1
0.1
0.01
0.2
0.4
0.6
1
0.8
1.2
1.4
1.6
TJ=25°C
20
40
60
80
100
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 5 - REVERSE SWITCHING CHARACTERISTICS
PER LEG
FIG. 6 - TYPICAL JUNCTION CAPACITANCE PER LEG
100
300
TJ=125°C
f=1.0 MHz
Vsig=50MVp-p
@5A, 50A/µs
250
200
@2A, 20A/µs
150
@5A, 50A/µs
100
@2A, 20A/µs
CAPACITANCE, pF
STORED CHARGE/REVERSE RECOVERY TIME,
nC/ns
100
10
1
10
50
trr
Qrr
@1A, 100A/µs
0
25
50
75
100
JUNCTION TEMPERATURE, °C
125
1
0.1
1
10
100
REVERSE VOLTAGE, VOLTS
1,000