SANYO LA5587

Ordering number:ENN2574A
Monolithic Linear IC
LA5587
General-Purpose
Compact DC Moter Speed Controller
Features
Package Dimensions
• On-chip stable voltage reference meeting the requirements
for various motors.
• Wide operating voltage range (3.8 to 16V).
• Minimum number of external parts required and smallsized package.
• Facilitates speed control.
• On-chip kickback absorber.
• On-chip protector against inverted connection to power
supply.
unit:mm
3042C-SIP5
[LA5587]
7.9max
6.5
3.8
1.2 min
9.4
3.0
1
1.5
0.6
5
0.6
0.25
1.33
2.0
Specifications
SANYO : SIP5
Maximum Ratings at Ta = 25˚C
Parameter
Symbol
Maximum supply voltage
Conditions
Ratings
Unit
VCC max
Motor current
Im max
Allowable power dssipation
Pd max
18
Switch ON or lock mode
V
1.4
A
1.2
W
Operating temperature
Topr
–20 to +80
˚C
Storage temperature
Tstg
–40 to +150
˚C
Operating Conditions at Ta = 25˚C
Parameter
Symbol
Recommended operating voltage
Recommended operating temperature
Conditions
Ratings
VCC op
Topr
Unit
3.8 to 16
V
–20 to +80
˚C
Operating Characteristics at Ta = 25˚C, See Test Circuit.
Parameter
Reference voltage
Quiescent current drain
Shunt ratio
Residual voltage
Symbol
Conditions
Vref
VCC=12V, Im=10mA
Id
VCC=12V, Im=0mA
K
VCC=12V, Im=50–150mA
VCC=4.2V, RT=4.4Ω
V(sat)
Ratings
min
1.08
typ
max
Unit
1.21
1.27
V
1.0
1.6
mA
20
22
18
0.94
V
Continued on next page.
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges,or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
40500TN (KT)/8280TS/6237KI, TS No.2574–1/3
LA5587
Continued from preceding page.
Parameter
Voltage characteristic of reference voltage
Voltage characteristic of shunt ratio
Current characteristic of reference voltage
Symbol
min
∆Vref
/∆VCC VCC=6.3 to 16V, Im=100mA
Vref
∆K
/∆VCC
K
∆Vref
/∆Im
Vref
VCC=6.3 to 16V, Im=50–150mA
VCC=12V, Im=30 to 200mA
Unit
0.06
%/V
0.1
%/V
0.02
%/mA
0.1
%/V
VCC=12V, Im=10mA, Ta=–20 to +80°C
–0.01
%/˚C
VCC=12V, Im=50–150mA, Ta=–20 to +80°C
–0.01
%/˚C
VCC=12V, Im=50–100 to 150–200mA
Voltage characteristic of reference voltage
∆Is
/∆VCC
Is
VCC=6 to 16V, Im=0mA
∆K
/∆Ta
K
max
%/mA
∆K
/∆Im
K
Temperature characteristic of reference voltage ∆Vref /∆Ta
Vref
typ
–0.01
Current characteristic of shunt ratio
Temperature characteristic of reference voltage
Ratings
Conditions
Equivalent Circuit Block Diagram and Test Circuit
Sample Application Circuit
IS + Im
) + Vref,
K
EO=Vref + RT (1 + 1 ) IS + ( RT –Rm) Im
K
K
From Im · Rm + EO=RT (IS +
Assuming K · Rm=RT,
The number of revolutions is determined by
EO=Vref + RT (1 +
1
)I
K S
Unless RT (max) < K · Rm (min) in the Sample
Application Circuit, the operation becomes
unstable.
No.2574–2/3
LA5587
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer's
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer's products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products(including technical data,services) described or
contained herein are controlled under any of applicable local export control laws and regulations,
such products must not be expor ted without obtaining the expor t license from the authorities
concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification"
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of April, 2000. Specifications and information herein are subject to
change without notice.
PS No.2574–3/3