SANYO LA5620

Ordering number : EN5639
Monolithic Linear IC
LA5620
Regulator for Multiple Power Supply Systems
Overview
Package Dimensions
The LA5620 is a multi-system power supply regulator IC
that includes four regulator circuits on chip: two 3.3-V
regulator circuits and two 5-V regulator circuits. The
LA5620 is optimal for use in audio and video systems that
use a microcontroller, such as MD players and stereo
components.
unit: mm
3049A-SIP12H
[LA5620]
Functions and Features
•
•
•
•
Two 3.3-V regulator circuits (IO = 40 mA, 150 mA)
Two 5-V regulator circuits (IO = 1000 mA, 100 mA)
Power on/off detection circuit
Reset circuit
SANYO: SIP12H
Specifications
Maximum Ratings at Ta = 25°C
Parameter
Symbol
Conditions
Ratings
Unit
Input voltage
VCC max
14
AC input voltage
AC max
2
V
Allowable power dissipation
Pd max
2.3
W
Independent IC
V
Operating temperature
Topr
–20 to +80
°C
Storage temperature
Tstg
–55 to +150
°C
Operating Conditions at Ta = 25°C
Parameter
Symbol
Conditions
Ratings
Unit
Input voltage
VCC
6.25 to 12
V
PH5 output current
IPH5
0 to 1000
mA
B.BAK output current
IB.BAK
0 to 40
mA
ANA5 output current
IANA5
0 to 100
mA
SYS3.3 output current
ISYS3.3
0 to 150
mA
S.RESET sink current
ISINK S
0 to 1
mA
P.DOWN sink current
ISINK P
0 to 1
mA
IAC
0 to 1
mA
AC input current
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
43097HA(OT) No. 5639-1/4
LA5620
Electrical Characteristics at Ta = 25°C
Parameter
Symbol
Conditions
Ratings
min
typ
Unit
max
[PH5 Regulator Block] VCC = 10 V, IPH5 = 1 A
Output voltage
VO PH5
Dropout voltage
VDROP PH5
Line regulation
∆VOLN PH5
VCC = 6.25 to 12 V
–
–
200
mV
Load regulation
∆VOLD PH5
IPH5 = 0.5 to 1 A
–
–
200
mV
Peak output current
Output shorted current
Current drain
IOP
4.75
5
5.25
V
–
0.5
1
V
1.0
1.4
–
IOSC PH5
–
400
1000
mA
A
IQ PH5
–
70
112
mA
3.13
3.3
3.47
V
–
2
2.5
V
–
–
200
mV
[SYS3.3 Regulator Block] VCC = 10 V, ISYS3.3 = 150 mA
Output voltage
VO SYS3.3
Dropout voltage
VDROP SYS3.3
Line regulation
∆VOLN SYS3.3
VCC = 6.25 to 12 V
Load regulation
∆VOLD SYS3.3
ISYS3.3 = 5 to 150 mA
–
–
200
mV
Peak output current
IOP SYS3.3
150
210
–
mA
Output shorted current
IOSC SYS3.3
–
200
450
mA
IQ SYS3.3
–
17.5
28
mA
4.75
5
5.25
V
–
0.5
1
V
Current drain
[ANA5 Regulator Block] VCC = 10 V, IANA5 = 100 mA
Output voltage
VO ANA5
Dropout voltage
VDROP ANA5
Line regulation
∆VOLN ANA5
VCC = 6.25 to 12 V
–
–
200
mV
Load regulation
∆VOLD ANA5
IANA5 = 5 to 100 mA
–
–
200
mV
Peak output current
IOP ANA5
100
140
–
mA
Output shorted current
IOSC ANA5
–
40
100
mA
IQ ANA5
–
17.5
28
mA
3.13
3.3
3.47
–
2
2.5
V
–
–
200
mV
Current drain
[B.BAK Regulator Block] VCC = 10 V, IBAK = 40 mA
Output voltage
VO BAK
Dropout voltage
VDROP BAK
Line regulation
∆VOLN BAK
VCC = 6.25 to 12 V
Load regulation
∆VOLD BAK
IBAK = 5 to 40 mA
V
–
–
200
mV
Peak output current
IOP BAK
40
56
–
mA
Output shorted current
IOSC BAK
–
40
120
mA
Current drain
IQ BAK
–
15
24
mA
BAK pin input current
IIN BAK
–
–
100
nA
3.0
3.16
3.32
V
–
–
200
mV
75
100
125
ms
VCC = 0 V, VBAK = 3.3 V
[P.DOWN Detection Circuit] VCC = 10 V
P.DOWN threshold voltage
VTH P.DOWN
P.DOWN residual voltage
Vsat P.DOWN
P.DOWN delay time
Td1
cd1 pin = shorted, P.DOWN pin = 1 mA
cd1 = 1 µF
[S.RESET Detection Circuit] VCC = 10 V
S.RESET residual voltage
S.RESET delay time
VTH S.RESET
–
–
200
mV
75
100
125
ms
VTH AC
0.5
0.7
0.9
V
VTH STBY
1.3
1.8
2.3
V
Td2
cd1 pin = shorted, S.RESET pin = 1 mA
cd2 = 1 µF
[AC Detection Circuit] VCC = 10 V
AC threshold voltage
[STBY Detection Circuit] VCC = 10 V
STBY threshold voltage
No. 5639-2/4
Allowable power dissipation, Pd max – Ta
LA5620
Ambient temperature, Ta – °C
Pin Assignment
Block Diagram
Delay circuit
SYS 3.3
Delay circuit
Note: Use capacitors with minimal temperature variations for all capacitors in application circuits.
No. 5639-3/4
LA5620
Timing Chart
AC pin
VCC pin
PH5 pin
Backup
B.BAK output
ANA output
SYS3.3 output
P. DOWN
P. RESET
■ No products described or contained herein are intended for use in surgical implants, life-support systems, aerospace
equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and the like, the failure of
which may directly or indirectly cause injury, death or property loss.
■ Anyone purchasing any products described or contained herein for an above-mentioned use shall:
➀ Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and
distributors and all their officers and employees, jointly and severally, against any and all claims and litigation and all
damages, cost and expenses associated with such use:
➁ Not impose any responsibility for any fault or negligence which may be cited in any such claim or litigation on
SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of their officers and employees
jointly or severally.
■ Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for
volume production. SANYO believes information herein is accurate and reliable, but no guarantees are made or implied
regarding its use or any infringements of intellectual property rights or other rights of third parties.
This catalog provides information as of April, 1997. Specifications and information herein are subject to change
without notice.
No. 5639-4/4