SANYO SPM3255

Ordering number:ENN6351
SPM3255
Single Power Supply Operation
RF Switch MMIC
Features
Package Dimensions
· Control voltage +3 / 0V.
· Mini molded package.
· Low insertion loss, high linearity.
unit:mm
1273
[SPM3255]
0.6
0.4
6
0.16
4
0.95 0.95
1.9
2.9
3
1 : CTL – RX
2 : ANT
3 : CTL – TX
4 : TX
5 : GND
6 : RX
SANYO : CP6
0.8
1.1
1
0.6
1.6
2.8
0 to 0.1
Specifications
Absolute Maximum Ratings at Ta = 25˚C
Parameter
Symbol
Control Voltage
Conditions
Ratings
Unit
5
V
Storatge Temperature
VCTL
Tstg
–55 to +150
˚C
Operating Temperature
Topr
–20 to +70
˚C
Electrical Characteristics at Ta = 25˚C
Parameter
Conditions
(Control voltage + 3 / 0V)
Symbol
Insertion Loss
Control Current
Isolation
VSWR
Ratings
min
typ
TX – ANT, ANT – RX
f=810 to 1033MHz
TX – ANT, ANT – RX
f=1.9GHz
RX, TX
f=1.9GHz
TX – ANT, ANT – RX
f=810 to 1033MHz
24
TX – ANT, ANT – RX
f=1.9GHz
20
TX – ANT, ANT – RX
f=810 to 1033MHz
1.1
0.6
max
0.5
dB
0.9
dB
50
µA
dB
22
dB
1.3
TX – ANT, ANT – RX
f=1.9GHz
1.4
2.0
Switching Time
Tsw
f=810MHz to 1.9GHz
20
100
P1dB
TX – ANT, ANT – RX
f=810MHz to 1.9GHz
17
Unit
20
ns
dBm
Marking : ML
CTL – TX
CTL – RX
+ 3V
0V
TX → ANT
0V
+ 3V
ANT → RX
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges,or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
12000GI (KT) No.6351–1/3
SPM3255
Sample Application Circuit
CTL -- RX
RX
ANT
TX
(
CTL -- TX
Zo = 50Ω)
Insertion loss -- Input power
0
Isolation -- Input power
--5
Vctl+3 / 0V, f=900MHz
--10
Isolation(dB)
Insertion loss(dB)
--1
--2
--3
--15
--20
--25
--4
--5
--30
0
5
10
15
20
25
Input power(dBm)
0
5
10
15
20
25
Input power(dBm)
IT01413
IT01414
Insertion loss -- Frequency
Input-output Characteristics
25
0
Vctl+3 / 0V, f=900MHz
Vctl+3 / 0V, Pin=+10dBm
--1
Insertion loss(dB)
20
Output power(dBm)
Vctl+3 / 0V, f=900MHz
15
10
--2
--3
--4
5
0
0
5
10
15
20
25
Input power(dBm)
30
IT01415
--5
0.5
1.0
1.5
2.0
Frequency(GHz)
2.5
3.0
IT01416
Isolation -- Frequency
--5
Vctl+3 / 0V, Pin=+10dBm
Isolation(dB)
--10
--15
--20
--25
--30
0.5
1.0
1.5
2.0
Frequency(GHz)
2.5
3.0
IT01417
No.6351–2/3
SPM3255
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer's
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer's products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products(including technical data,services) described or
contained herein are controlled under any of applicable local export control laws and regulations,
such products must not be expor ted without obtaining the expor t license from the authorities
concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification"
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of January, 2000. Specifications and information herein are subject
to change without notice.
PS No.6351–3/3