SANYO SMA4203

Ordering number : ENN0000
SMA4203
Si Monolithic Linear IC
SMA4203
Oscillator IC
for Laser Diode Noise Suppression Applications
Preliminary
Package Dimensions
unit : mm
0000
0.25
5
0.15
4
0 to 0.1
1.25
2.1
6
0.2
0.425
[SMA4203]
0.2
0.425
3
0.9
1 2
0.65
2.0
(2) and (5) are common terminals.
Specifications
Please ground either of them.
SANYO : MCP6
Absolute Maximum Ratings at Ta=25°C
Parameter
Symbol
1 : LC
2 : GND
3 : OPEN
4 : VCC
5 : GND
6 : OUT
Conditions
Ratings
Unit
Supply Voltage
VCC
6.0
V
Supply Current
60
mA
Allowable Power Dissipation
ICC
PD
280
mW
Operating Temperature
Topr
--20 to +85
°C
Storage Temperature
Tstg
--55 to +150
°C
Electrical Characteristics at Ta=25°C
Parameter
Symbol
Supply Current
ICC
Posc
Oscillation Power
Ratings
Conditions
min
VCC=5V, RL=50Ω, fosc=400MHz
VCC=5V, RL=50Ω, fosc=400MHz
typ
max
Unit
37
42
47
mA
4.5
7
8.5
dBm
NOTE : * Oscillation frequency mainly depends on the external LC.
(The LC is attached additionally to the LC terminal in series.)
* Recommended oscillation frequency.
350MHz to 450MHz
Marking : S2W
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft's
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
HD seigi 011030 / 60601 TS IM NAKATANI No.0000-1/3
SMA4203
[Reference data]
Oscillation Frequency vs L, C
Power Supply Voltage vs Oscillation Power
L=47nH, C=10pF
L
C
nH
pF
--3.0
68
--0.4
68
18.8
1.4
3.2
21.5
3.4
3.6
Power Supply Voltage Supply Current Oscillation Power Oscillation Frequency
ICC
mA
Pout
fosc
V
dBm
MHz
68
3.0
19.3
2.3
284
68
4.0
31.3
6.0
289
68
68
5.0
41.5
7.0
295
2.8
47
7
3.0
18.8
1.4
406
24.0
3.9
47
7
4.0
31.2
5.4
406
26.5
4.5
47
7
5.0
41.8
6.6
405
3.8
28.9
5.0
68
7
3.0
19.0
2.1
336
4.0
31.2
5.4
68
7
4.0
31.5
5.9
337
4.2
33.4
5.8
68
7
5.0
42.0
6.8
340
4.4
35.6
6.0
82
7
3.0
18.9
1.9
310
4.6
37.7
6.2
82
7
4.0
31.4
5.9
312
4.8
39.7
6.4
82
7
5.0
41.8
6.8
316
5.0
41.8
6.6
100
7
3.0
18.6
1.5
290
100
7
4.0
31.4
5.8
292
100
7
5.0
41.7
6.8
297
VCC
Oscillation Power
V
ICC
mA
2.6
13.0
2.8
16.0
3.0
dBm
VCC
Equivalent Circuit
VCC
LC
OUT
GND
Test Circuit
47pF
1
RF
6
OUTPUT
47nH
2
5
3
4
VCC
10pF
1000pF
No.0000-2/3
SMA4203
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer's
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer's products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products(including technical data,services) described or
contained herein are controlled under any of applicable local export control laws and regulations,
such products must not be expor ted without obtaining the expor t license from the authorities
concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification"
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of June, 2001. Specifications and information herein are subject
to change without notice.
PS No.0000-3/3