Présente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com P NHG RELAYS P R R5604271 C US E158859 Patent No 02217796.5 14.0 9.0 5.0 DIL Pitch Terminals .High Sensitivity :0.14W or 0.10W Nominal Power Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC Monostable or bistable relays Single and double Coil magnet latching Type available Application for Telecommunication Equipment,Office Equipment,Security Alarm Systems, Measuring instruments, Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control Ordering Information L Electrostatic capacitance Between open Contacts Between coil & Contacts Between Contact Poles Approx.0.4pF Approx.0.9pF Approx.0.2pF Item 3.41 of IEC255-7 Item 3.41 of IEC255-7 Item 3.41 of IEC255-7 Insulation Resistance 1000M Item 7 of IEC255-5 min (at 500VDC) Dielectric Strength Features P Characteristics 12 W 1 2 3 4 1 Part number P 2 Operating function NIL: Single Side Stable L:1 Coil Latching; K:2 Coil Latching 3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24 4 Contact material NIL: AgPd W: AgNi Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation life 2C DPDT(B-M) Bifurcated Crossbar AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad 1A,2A/30VDC; 0.5A/125VAC 60W 62.5VA Min. Switching load 0.01mA/10mV Reference Value 220VDC 250VAC M ax. Swit ching Curr ent:2A 50m Electrical Mechanical Item 3.12 of IEC255-7 1A/30VDC 2 10 5 Ag Ni 1 10 5 0.5A/125VAC 1 10 5 10 8 Item 6 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 Surge Withstand Voltage Between open Contacts Between coil & Contacts Between Contact Poles 1500V 1500V 2500V FCC68 FCC68 FCC68 Shock resistance Functional:500m/s 2 11ms; Survival:1000 m/s2 6ms IEC68-2-27 Test Ea Vibration resistance 10~55Hz Double amplitude Functional 3mm Survival:5mm IEC68-2-6 Test Fc Terminals strength Solderability Temperature Range Mass 5N 235 2 3 0.5s -40~70 (-40~158 F) 1.5g IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 Qualification inspection: Perform the qualification test as specified in the table Safety approval of IEC255-19-1 and minimum sample size 24. UL&CUR Load CAUTION: DC or peak AC 1000VAC 1min 1000VAC 1min 1000VAC 1min Safety approvals Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 Relays previously tested or used above 10mA resistive at 6V maximum recommended for subsequent use in low level applications. Between open Contacts Between coil & Contacts Between Contact Poles open circuit are not TU V 1A,2A/30VDC, 0.5A/125VAC 1A/30VDC, 0.5A/125VAC Dimensions mm/inch P-003 P-004 P-005 P-006 P-009 P-012 P-024 3 4.5 5 6 9 12 24 Max. 7.5 11.25 12.5 15.0 22.5 30.0 48.0 64.3 144.6 178 257 579 1028 2880 2.25 3.38 3.75 4.50 6.75 9.00 18.0 1 Coil Latching PL-003 PL-004 PL-005 PL-006 PL-009 PL-012 PL-024 Coil power W 0.3 0.45 0.5 0.6 0.9 1.2 2.4 0.14 0.14 0.14 0.14 0.14 0.14 0.20 Operate Time ms Approx.2 3 4.5 5 6 9 12 24 8.7 13.0 14.5 17.4 26.1 34.8 57.6 3 4.5 5 6 9 12 24 6 9 10 12 18 24 36 90 202.5 250 360 810 1440 3840 Set Coil 45 101 125 180 405 720 1920 2.25 3.38 3.75 4.50 6.75 9.00 18.0 2.25 3.38 3.75 4.50 6.75 9.00 18.0 2.25 3.38 3.75 4.50 6.75 9.00 18.0 Index Mark 0.5 0.02 0.10 0.10 0.10 0.10 0.10 0.10 0.15 7.62 0.3 2.54 0.1 1 Approx.2 Single Side stable 2 3 4 5 1 1 Coil latching 2 3 4 5 1 2 Coil latching 2 3 4 5 SR Approx.1 S R S: Set R: Reset (Bottom View) Reset 0.20 0.20 0.20 0.20 0.20 0.20 0.30 0.25 0.01 2.54 0.1 14max. 0.55max. Approx.1 Reset Reset(Max) Reset Coil 45 101 125 180 405 720 1920 -2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.0 Release /Reset Time ms Dimensions Reset(Max) 2 Coil Latching PK-003 PK-004 PK-005 PK-006 PK-009 PK-012 PK-024 Release voltage VDC(min) (10% of rated voltage) 4.75 0.187 Pick up voltage VDC(max) (75%of rated voltage ) 2.54 0.1 Rated Coil resistance 10% 3.5 0.187 Coil voltage VDC 9max. 0.354max. Dash numbers 5 +0.4 0.197 +0.016 Coil Parameter 10 9 8 7 6 Index mark (De-energized Position) Approx.2 Approx.1 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria. 3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetically neutral position . 10 9 8 7 Index mark (Reset Position) 6 10 9 8 7 6 Index mark (Reset Position) Wiring diagram (Bottom view) 10- 1 0.04 Tolerance: 0.1/0.004 Mounting (Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Ningbo Huaguan Relay Corporation LTD.