DBLECTRO P12

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
P
NHG RELAYS
P
R
R5604271
C
US E158859
Patent No 02217796.5
14.0 9.0 5.0
DIL Pitch Terminals .High Sensitivity :0.14W or 0.10W Nominal Power
Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC
Monostable or bistable relays Single and double Coil magnet latching Type available
Application for Telecommunication Equipment,Office Equipment,Security Alarm Systems, Measuring instruments,
Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control
Ordering Information
L
Electrostatic capacitance
Between open Contacts
Between coil & Contacts
Between Contact Poles
Approx.0.4pF
Approx.0.9pF
Approx.0.2pF
Item 3.41 of IEC255-7
Item 3.41 of IEC255-7
Item 3.41 of IEC255-7
Insulation Resistance
1000M
Item 7 of IEC255-5
min (at 500VDC)
Dielectric Strength
Features
P
Characteristics
12 W
1
2
3
4
1 Part number P
2 Operating function NIL: Single Side Stable
L:1 Coil Latching; K:2 Coil Latching
3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24
4 Contact material NIL: AgPd W: AgNi
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or
Voltage drop
Operation
life
2C DPDT(B-M)
Bifurcated Crossbar
AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad
1A,2A/30VDC; 0.5A/125VAC
60W
62.5VA
Min. Switching load 0.01mA/10mV Reference Value
220VDC 250VAC
M ax. Swit ching Curr ent:2A
50m
Electrical
Mechanical
Item 3.12 of IEC255-7
1A/30VDC 2 10 5 Ag Ni 1 10 5
0.5A/125VAC 1 10 5
10 8
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
Surge Withstand Voltage
Between open Contacts
Between coil & Contacts
Between Contact Poles
1500V
1500V
2500V
FCC68
FCC68
FCC68
Shock resistance
Functional:500m/s 2 11ms;
Survival:1000 m/s2 6ms
IEC68-2-27 Test Ea
Vibration resistance
10~55Hz Double amplitude Functional 3mm
Survival:5mm
IEC68-2-6 Test Fc
Terminals strength
Solderability
Temperature Range
Mass
5N
235
2
3 0.5s
-40~70 (-40~158 F)
1.5g
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
Qualification inspection:
Perform the qualification test as specified in the table
Safety approval
of IEC255-19-1 and minimum sample size 24.
UL&CUR
Load
CAUTION:
DC or peak AC
1000VAC 1min
1000VAC 1min
1000VAC 1min
Safety approvals
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Relays previously tested or used above 10mA resistive at 6V maximum
recommended for subsequent use in low level applications.
Between open Contacts
Between coil & Contacts
Between Contact Poles
open circuit are not
TU V
1A,2A/30VDC, 0.5A/125VAC
1A/30VDC, 0.5A/125VAC
Dimensions
mm/inch
P-003
P-004
P-005
P-006
P-009
P-012
P-024
3
4.5
5
6
9
12
24
Max.
7.5
11.25
12.5
15.0
22.5
30.0
48.0
64.3
144.6
178
257
579
1028
2880
2.25
3.38
3.75
4.50
6.75
9.00
18.0
1 Coil Latching
PL-003
PL-004
PL-005
PL-006
PL-009
PL-012
PL-024
Coil
power
W
0.3
0.45
0.5
0.6
0.9
1.2
2.4
0.14
0.14
0.14
0.14
0.14
0.14
0.20
Operate
Time
ms
Approx.2
3
4.5
5
6
9
12
24
8.7
13.0
14.5
17.4
26.1
34.8
57.6
3
4.5
5
6
9
12
24
6
9
10
12
18
24
36
90
202.5
250
360
810
1440
3840
Set Coil
45
101
125
180
405
720
1920
2.25
3.38
3.75
4.50
6.75
9.00
18.0
2.25
3.38
3.75
4.50
6.75
9.00
18.0
2.25
3.38
3.75
4.50
6.75
9.00
18.0
Index Mark
0.5
0.02
0.10
0.10
0.10
0.10
0.10
0.10
0.15
7.62
0.3
2.54
0.1
1
Approx.2
Single Side stable
2
3
4
5
1
1 Coil latching
2
3
4
5
1
2 Coil latching
2
3
4
5
SR
Approx.1
S
R
S: Set
R: Reset
(Bottom View)
Reset
0.20
0.20
0.20
0.20
0.20
0.20
0.30
0.25
0.01
2.54
0.1
14max.
0.55max.
Approx.1
Reset
Reset(Max)
Reset Coil
45
101
125
180
405
720
1920
-2.25
-3.38
-3.75
-4.50
-6.75
-9.00
-18.0
Release
/Reset
Time
ms
Dimensions
Reset(Max)
2 Coil Latching
PK-003
PK-004
PK-005
PK-006
PK-009
PK-012
PK-024
Release voltage
VDC(min)
(10% of rated
voltage)
4.75
0.187
Pick up voltage
VDC(max)
(75%of rated
voltage )
2.54
0.1
Rated
Coil resistance
10%
3.5
0.187
Coil voltage
VDC
9max.
0.354max.
Dash
numbers
5 +0.4
0.197 +0.016
Coil Parameter
10
9
8
7
6
Index mark
(De-energized Position)
Approx.2
Approx.1
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design
criteria.
3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed
simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width
should be a minimum of three times the specified operate time of the relay. If these conditions are not
followed, it is possible for the relay to be in the magnetically neutral position .
10
9
8
7
Index mark
(Reset Position)
6
10
9
8
7
6
Index mark
(Reset Position)
Wiring diagram
(Bottom view)
10- 1
0.04
Tolerance: 0.1/0.004
Mounting (Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Huaguan Relay Corporation LTD.