DBLECTRO PS12

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
PS
NHG RELAYS
PS
R
C
14.2 9.3 5.3
US
R50044271
E158859
Features
Electrostatic capacitance
Between open Contacts
Between coil & Contacts
Between Contact Poles
Approx.0.4pF
Approx.0.9pF
Approx.0.2pF
Item 3.41 of IEC255-7
Item 3.41 of IEC255-7
Item 3.41 of IEC255-7
Insulation Resistance
1000M
Item 7 of IEC255-5
min (at 500VDC)
Dielectric Strength
Surface mount Type with “L ” shaped Terminals.
Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC.
Monostable or bistable relays Single and double Coil magnet latching Type available.
Application for Telecommunication Equipment,Office Equipment, Security Alarm Systems, Measuring instruments,
Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control.
Ordering Information
PS L
Characteristics
12 W
1
2
3
4
1 Part number PS
2 Operating function Nil: Single Side Stable
L:1 Coil Latching K:2 Coil Latching
Operation al
life
Electrical
Mechanical
1000VAC 1min
1000VAC 1min
1000VAC 1min
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
Surge Withstand Voltage
Between open Contacts
Between coil & Contacts
Between Contact Poles
1500V
1500V
2500V
FCC68
FCC68
FCC68
Functional:500m/s 2 11ms;
Survival:1000 m/s2 6ms
IEC68-2-27 Test Ea
Shock resistance
3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24
4 Contact material Nil: AgPd W: AgNi
2C DPDT(B-M)
Bifurcated Crossbar
AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad
1A,2A/30VDC; 0.5A/125VAC
60W 62.5VA
Min. Switching load 0.01mA/10mV
220VDC 250VAC
Max. Switching Current:2A
50m
Reference Value
Temperature Range
Mass
-40~85 (-40~185 F)
1.5g
Safety approval
Item 3.31 of IEC255-7
Load
CAUTION:
DC or peak AC
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
of IEC255-19-1 and minimum sample size 24.
Safety approvals
Item 3.30 of IEC255-7
Relays previously tested or used above 10mA resistive at 6V maximum
recommended for subsequent use in low level applications.
IEC68-2-6 Test Fc
Qualification inspection:
Perform the qualification test as specified in the table
Item 3.12 of IEC255-7
2 10 5 (DC AgPd);1 10 5(DC AgNi)
1 10 5 (AC)
108
Terminals strength
Solderability
10~55Hz Double amplitude Functional 3mm
Survival:5mm
5N
235
2
3 0.5s
Vibration resistance
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or
Voltage drop
Between open Contacts
Between coil & Contacts
Between Contact Poles
open circuit are not
UL&CUR
TU V
1A,2A/30VDC 0.5A/125VAC
1A/30VDC
Dimensions
0.5A/125VAC
mm/inch
3
4.5
5
6
9
12
24
7.5
11.25
12.5
15.0
22.5
30.0
48.0
64.3
144.6
178
257
579
1028
2880
2.25
3.38
3.75
4.50
6.75
9.00
18.0
3
4.5
5
6
9
12
24
8.7
13.0
14.5
17.4
26.1
34.8
57.6
90
202.5
250
360
810
1440
3840
2.25
3.38
3.75
4.50
6.75
9.00
18.0
3
4.5
5
6
9
12
24
6
9
10
12
18
24
36
1 Coil Latching
PSL-003
PSL-004
PSL-005
PSL-006
PSL-009
PSL-012
PSL-024
0.14
0.14
0.14
0.14
0.14
0.14
0.20
Set Coil
45
101
125
180
405
720
1920
2.25
3.38
3.75
4.50
6.75
9.00
18.0
2.25
3.38
3.75
4.50
6.75
9.00
18.0
Index Mark
0.5
0.02
Approx.2
2.02
0.08
Approx.1
2.54
0.1
14.2max.
0.559max.
7.62
0.3
A
B
Stand-off
11.5
0.453 0.020
Dimensions
1.5
0.059
0.68
0.027
1
0.039
Reset
0.10
0.10
0.10
0.10
0.10
0.10
0.15
1
Approx.2
5
1
1 Coil latching
2
3
4
5
1
2 Coil latching
2
3
4
5
SR
Approx.2
S
S: Set
R: Reset
(Bottom View)
Reset
0.20
0.20
0.20
0.20
0.20
0.20
0.30
Single Side stable
2
3
4
R
Reset(Max)
Reset Coil
45
101
125
180
405
720
1920
-2.25
-3.38
-3.75
-4.50
-6.75
-9.00
-18.0
Release
/Reset
Time
ms
6.2 +0.4
0.244 0.016
0.3
0.45
0.5
0.6
0.9
1.2
2.4
Operate
Time
ms
0.25
0.01
Coil
power
W
Reset(Max)
2 Coil Latching
PSK-003
PSK-004
PSK-005
PSK-006
PSK-009
PSK-012
PSK-024
Release voltage
VDC(min)
(10% of rated
voltage)
3
0.118
PS-003
PS-004
PS-005
PS-006
PS-009
PS-012
PS-024
Max.
Pick up voltage
VDC(max)
(75%of rated
voltage )
2
0.079
Rated
Coil resistance
10%
9. 56
0.376
Coil voltage
VDC
9.3max.
0.366max.
Dash
numbers
5.3 +0.4
0.209 +0.016
Coil Parameter
10
9
8
7
6
Index mark
(De-energized Position)
Approx.2
Approx.2
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design
criteria.
3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed
simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width
should be a minimum of three times the specified operate time of the relay. If these conditions are not
followed, it is possible for the relay to be in the magnetically neutral position .
10
9
8
7
6
Index mark
(Reset Position)
10
9
8
7
Index mark
(Reset Position)
Wiring diagram
(Bottom view)
6
0.6
0.024
1.2
0.047
2.54
0.1
Soldering Pad (for Terminal)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Temporary glue Pad
(for Stand-off A or B)
Tolerance 0.1/ 0.004
Mounting (Bottom view)