FUJI EDS11-114B

FC SERIES MANUAL LOADER
(STEP OUTPUT TYPE)
DATA SHEET
PND3
One is used for remote control in combination with a compact controller, while the other is dedicated for manual operation.
This instrument is equipped with a solid state indicator and
pushbutton operation circuit to provide easy readouts and
handling for process operation by man-machine communication.
It can be directly connected to a thermocouple, resistance
bulb or 4 to 20mA input optionally.
FEATURES
1. High reliability
The manual loader is a solid state instrument having few
mechanical parts. The indicator and other units which
formerly consisted of mechanical parts are also designed
with solid state circuits to provide high reliability.
2. Application of international standards
This instrument is compact, and the external dimensions
comply with international IEC. The power supply and
signal also comply with IEC standards (24V, 1 to 5V DC).
Operation on 100V or 200V AC power supply is possible.
3. Front panel operation
Process values, valve position input, etc. can be read
accurately from the digital display on the panel front.
Parameter setting and manual operation are also possible
from the front of the panel.
FUNCTIONAL DIAGRAM
PV
Linearize
Square-root
extraction
MV
Manual mode
output (M)
Filter
Compensated
process value
signal (KPV)
Process value
input (PV)
A
External MV input
(Pulse width) (PI)
Limiter
Valve position
read back (W)
Manipulated output
(step output) (PO)
M
W/V
H
MV
L
High alarm output
Manual mode
command
(SMV)
ALM
Low alarm output
EDS11-114b
Date
Jan. 27, 1999
PND3
SPECIFICATIONS
1. Input signal
(1) Process value input signal:
One point of signal select from the following inputs
Voltage input signal
1 to 5V DC
Input resistance,
more than 1MΩ
Allow. error
± 0.2%/FS*
Current input signal
4 to 20mA DC
24V DC power supplied to transmitter
during AC operation
Allow. error
± 0.2%/FS*
10mV DC span or
more
Basic contact compensating function
Allow. error
± 0.5%/FS*
50°C span or more
Allow. error
± 0.5%/FS*
Thermocouple
input
I+
I0 Type
I – J:0 to 600°C
K:0 to 1200°C
E:0 to 800°C
R:0 to 1600°C
Resistance
bulb input
JPt100
–50 to 500°C
(2) Valve position input signal: 1 point
Voltage input
signal
W0 1 to 5V DC
Resistance
input signal
W+ 50 to 1000Ω 3-wire system potentiometer
Allow. error ± 0.5/FS*
W0 span**
W–
Input resistance, 1MΩ or more
Allow. error ± 0.5%/FS*
Note: ** : Basic design: 10 to 100 to 10Ω, others should be specified.
Contact input
(photo-coupler
insulation)
ON 0V, OFF 24V
(input current, approx.
11mA/24 DC)
(4) Digital input signal: 1 set
SMV Contact input
(photo-coupler
insulation)
Manual mode
command
ON 0V, OFF 24V
(input current, approx.
11mA/24 DC)
2. Output signal
(1) Control output signal: 1 set
P0+
P0–
Pulse width
output signal
Open-collector output (phone-coupler
insulation)
Output rating,
30V x 0.1A DC, max.
(2) Analog output signal: 1 point
Compensated
process value
signal
KPV
1 to 5V DC
Setting method: By using F/S ,
,
,
, ST , keys
on front panel
(4) Operating functions
Manual operating method:
By using of
,
buttons on front panel
Auto operating method:
By pulse width input signal
(5) Operation mode selection
By using front panel A/M pushbutton
A
M selection
Balanceless bumpless
4. Power failure processing functions
Power failure detection:
Control output OFF at power failure detection.
During power failure:
Data backed up by capacitor when power
failure occurs within 5 minutes.
Initial value of data stored in non-volatile
memory (last for more than 10 years at
ambient temperature of 50°C or less).
Power failure recovery time:
Initial or continuous start set for power
failure within 5 minutes.
Recovery from power failure lasting longer
than 5 minutes is done by initial.
Note: Control mode at initialization set.
M: Manual mode or A: Auto mode
Output resistance, 1Ω or less
Allow. error ± 0.2%/FS
5. Self-diagnosis functions
(3) Digital output signal: 4 points
Fault output
keys on front panel.
(6) Alarm function
High/low alarm can be set in industrial values for process
value input signal.
(3) Pulse width input signal: 1 set
PI+
PI–
Indication contents are select with F/S ,
,
Note: * FS: Full scale
Pulse width input
signal
(2) Operation mode indication
Indication method:
LED (red and green)
Red: M
Green: A
(3) Numerical indication, setting
Indication method:
LED (red), name in 3 digits + number in 5
digits (negative sign included)
Indication contens:
Process variable (industrial value), high/
low alarm, limiter value etc.
FLT
Manual mode output
M
High alarm output
H
Low alarm output
L
Open-collector output (photo-coupler
insulation)
Output rating,
30V x 0.1A DC,
max.
Process value input signal abnormality:
FLT indicator lights and FLT contact output turns ON.
Fault contents indication:
Cause of fault is indicated numerically on
numerical indicator on the front panel.
6. Other functions
3. Indication, setting, operating functions
Data protective function by use of pass code
(1) Bar graph indication
7. Operating conditions
Indication method
PV indicator
MV indicator
LED (red)
LED (red)
No. of indicating segments 101 + 2
51 + 2
Indication range
0 to 100%, linear
0 to 100%, linear
Indication resolution
1 %/FS
2%/FS
Scale length
100mm
50mm
Indication mode
0 to 100% bar graph indication,
0 to 100% reverse bar graph indication,
0 to 100% dot indication
Power supply:
Selected from the following 3 types
24V DC (20 to 30V DC)
100V AC (85 to 132V/47 to 63Hz AC)
200V AC (87 to 264V/47 to 63Hz AC)
Power consumption:
Approx. 11W (DC)
Approx. 20VA (AC)
Dielectric strength:
1500V AC, 1 min.
Insulation resistance:
100MΩ or more at 500V DC
Ambient temperature:
0 to 50°C
Ambient humidity:
90% RH or less
Enclosure:
Steel case
Nameplate:
100 (H) x 72 (W) mm, white acryl
Dimensions:
144 (H) x 72 (W) x 407 (D) mm, IEC
(DIN) standards
Mass{weight}:
Approx. 2.9kg
Mounting method:
Flush with indoor pane; vertical mounting
is standard.
Mounting on tilted surface possible (angle
"α")
CODE SYMBOLS
1 2 3 4 5 6 7 8
PND3
B
9
Description
5 -
Process value input signal
1 to 5V DC
4 to 20mA DC with 24V DC power supply
10mV DC span or
J thermocouple
more, with reference
K thermocouple
contact compensatE thermocouple
ing function
R thermocouple
Resistance bulb, Pt100, 3-wire, 50°C
span or more
A
B
C
D
E
F
G
Auxiliary analog input
None
B
Power supply
24V DC (20 to 30V DC)
100V AC (85 to 132V/47 to 63Hz AC)
200V AC (187 to 264V/47 to 63Hz AC)
1
2
3
1
2
α=0 to 90°
Valve position input signal
Voltage input signal (1 to 5V DC)
Resistance input signal (50 to 1000Ω
span) (Note)
Note: Basic: 10 to 100 to 10Ω, others should be
specified.
Finish color:
Munsell N1.5 for front panel and case
Range of delivery:Manual loader and mounting bracket
OUTLINE DIAGRAM
(Unit:mm)
Panel thickness 8mm or less
16
144
Terminals
Supporting
bracket
52
Mounting
bracket
200min.
72
355
Panel cutout
When mounting "n" units
138
+1
0
250min.
138
+1
0
200min.
When mounting one unit
68
+0.7
0
(72.2n – 4)
+1
0
No. of units
n 2
PND3
CONNECTION DIAGRAM
Compression terminal
Not use
Valve position read back
01
I+
31
02
I0
32
03
I–
33
KPV
34
04
W+
05
W0
06
W–
MV
36
AO
(Compensated PV signal)
Not use
AO
(Valve position transmission signal)
07
SC
SC
37
AI, AO Common bus
08
SC
SC
38
35
AI, AO Common bus
Not use
+
PO (Plus width)
(Manipulated output)
–
DI
(External MV input)
Process variable
input
09
39
10
40
11
41
12
P0 +
SMV
42
13
P0 –
43
14
PI +
44
15
PI –
45
16
H
46
17
L
47
DO
(High alarm output)
DO
(Low alarm output)
DO
(FLT output)
24VDC power for DI, DO
18
FLT
M
– 19
PCD
VPD
49 +
24VDC power for DI, DO
– 20
PCD
VPD
50 +
Instrument power
(24VDC)
– 21
PC *
VP *
51 +
G
AC
AC
71
72
73
48
Not use
DO
(Manual mode command)
Not use
DO
(Manual mode)
24VDC power for DI, DO
Instrument power
(24VDC)
Note: * Symbols for AC instrument power are VPO, PCO.
Output : Approx. 24V DC (0.1A max.)
Ground
INstrument power (AC)
Instrument power (AC)
Process value input terminal connections
1 to 5V DC
The 5th digit of
code symbols:
"A"
4 to 20mA DC
The 5th digit of
code symbols:
"B"
+
Thermocouple
The 5th digit of
code symbols:
C,D,E,F
31
32
+
–
33
+
31
Resistance bulb
The 5th digit of
code symbols:
G,W
32
–
–
33
+
31
–
33
+
+
31
–
–
33
+
31
–
33
32
32
+
4 to 20mA DC
power
The 5th digit of
code symbols:
"B"
–
32
PC
21
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
http://www.fesys.co.jp/eng
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http: //www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan