MEANWELL GS40A09-P1J

GS40
40W AC-DC Single Output Desktop
series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE
Class power (with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.3W
ErP step2 compliant
NRCan compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 years warranty
ORDER NO.
DC VOLTAGE
GS40A05
Note.2 5V
GS40A15
GS40A18
GS40A24
12V
15V
18V
24V
GS40A48
48V
3.34A
2.67A
2.22A
1.67A
0.84A
0 ~ 0.84A
4.45A
CURRENT RANGE
0 ~ 5A
0 ~ 5.34A
0 ~ 4.45A
0 ~ 3.34A
0 ~ 2.67A
0 ~ 2.22A
0 ~ 1.67A
RATED POWER (max.)
25W
40W
40W
40W
40W
40W
40W
40W
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
180mVp-p
240mVp-p
RIPPLE & NOISE (max.) Note.3 100mVp-p
VOLTAGE TOLERANCE Note.4
5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.5%
2.5%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.5%
2.5%
Note.5
Note.7 1000ms, 30ms / 230VAC
1000ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms / 230VAC
15ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80.5%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
1A / 115VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
85.5%
85%
PACKING
PLUG
CABLE
91%
92%
25.2 ~ 32.4V
50.4 ~ 64.8V
0.75mA / 240VAC
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
EMC IMMUNITY
90%
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V
7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +60
MTBF
DIMENSION
89.5%
65A / 230VAC
WORKING HUMIDITY
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 6)
EMC EMISSION
89%
0.5A / 230VAC
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
NOTE
GS40A12
9V
5.34A
LEAKAGE CURRENT(max.)
CONNECTOR
GS40A09
7.5V
5A
SETUP, RISE TIME
OTHERS
GS40A07
RATED CURRENT
LOAD REGULATION
INPUT
geprUfre
Sicherheit
GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J
SAFETY MODEL NO.
OUTPUT
TUV
Rheinland
Product Safety
(except for 48V)
SPECIFICATION
(Refer to "Derating Curve")
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
711Khrs min. MIL-HDBK-217F(25
)
125*50*31.5mm (L*W*H)
0.28Kg; 40pcs/12.02Kg/1.05CUFT
Standard type P1J: 2.1
* 5.5
* 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:GS40-SPEC 2012-03-06
GS40
40W AC-DC Single Output Desktop
Mechanical Specification
Case No. 974A
Unit:mm
UL1185 16AWG 1000 50mm for 5 ~ 15V
UL1185 18AWG 1800 50mm for 18 ~ 48V
125
31.5
series
POWER LED
70 10mm
50
C"+"
11 0.5mm
ID 2.1 x OD 5.5
Plug Assignment
Standard plug: P1J
P1J
Derating Curve
P/N
OUTPUT
CENTER
+
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS40-SPEC 2012-03-06