MEANWELL TP-75D

TP-75
75W Triple Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Low profile: 33mm thickness
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
TP-75A
CH2
CH3
CH1
CH2
CH3
CH1
CH2
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
7A
3A
0.6A
7A
3A
0.4A
6A
2.5A
0.5A
CURRENT RANGE
1.5 ~ 10A
0.2 ~ 4A
0 ~ 0.6A
1.5 ~ 10A
0.2 ~ 4A
0 ~ 0.6A
1.5 ~ 10A
0.2 ~ 3A
0 ~ 0.6A
RATED POWER
74W
120mVp-p
120mVp-p
120mVp-p
120mVp-p
100mVp-p
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
800ms, 60ms at full load
36ms at full load
Note.5 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
70%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.5A/115VAC
0.8A/115VAC
COLD START 20A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
NOTE
100mVp-p
VOLTAGE TOLERANCE Note.3
PROTECTION
OTHERS
100mVp-p
75W
CH1: 4.75 ~ 5.5V
OVERLOAD
(Note 4)
120mVp-p
CH3
LINE REGULATION
VOLTAGE RANGE
EMC
75.8W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
HOLD UP TIME (Typ.)
SAFETY &
TP-75C
CH1
SETUP, RISE TIME
INPUT
TP-75B
OUTPUT NUMBER
PF>0.98/115VAC at full load
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V on +5V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
0.03%/
, 10 ~ 95% RH
(0 ~ 50
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
Compliance to EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
/ 70% RH
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
198.4K hrs min. MIL-HDBK-217F (25
179*99*33mm (L*W*H)
0.65Kg; 20pcs/12.7Kg/0.64CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:TP-75-SPEC 2010-10-18
TP-75
75W Triple Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload/ Over voltage
Low profile: 33mm thickness
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
TP-75D
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
5V
24V
12V
5V
3.3V
12V
RATED CURRENT
7A
1.5A
0.4A
9A
8A
0.3A
CURRENT RANGE
1.5 ~ 10A
0.2 ~ 2.5A
0 ~ 0.6A
1.5 ~ 10A
0.2 ~ 8A
0 ~ 0.6A
RATED POWER
75.8W
50mVp-p
120mVp-p
120mVp-p
100mVp-p
VOLTAGE TOLERANCE Note.3
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
VOLTAGE RANGE
800ms, 60ms at full load
36ms at full load
Note.5 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.95/230VAC
EFFICIENCY (Typ.)
70%
AC CURRENT
INRUSH CURRENT (max.)
1.5A/115VAC
0.8A/115VAC
COLD START 20A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
120mVp-p
CH1: 4.75 ~ 5.5V
HOLD UP TIME (Typ.)
OTHERS
75W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
SETUP, RISE TIME
INPUT
TP-7503
OUTPUT NUMBER
PF>0.98/115VAC at full load
5.75 ~ 6.75V on +5V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
Compliance to EN55022 (CISPR22) Class B
/ 70% RH
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
198.4K hrs min. MIL-HDBK-217F (25
179*99*33mm (L*W*H)
0.65Kg; 20pcs/12.7Kg/0.64CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:TP-75-SPEC 2010-10-18
TP-75
75W Triple Output with PFC Function
Mechanical Specification
Case No. 920A
60
series
Unit:mm
65
LED
99
49.5
2-M4 L=4mm
16
7.62
6.15
1
2
3
4
5
6
7
8
119
+ADJ.
15
Terminal Pin No. Assignment
25
117
32.5
18
33
17
8
9 max.
Pin No.
1
2,3
4
5
Assignment
DC OUTPUT +V2
COM
DC OUTPUT +V1
DC OUTPUT +V3
Pin No.
6
7
8
Assignment
FG
AC/N
AC/L
6-M4 L=6mm
179
Block Diagram
PFC fosc : 67KHz
PWM fosc : 134KHz
EMI FILTER
&
RECTIFIERS
I/P
PFC
CIRCUIT
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
O.L.P.
+V
-V
CONSTANT
CURRENT
LIMITING &
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25
With 18CFM
Forced AIR
100
100
90
(15cm)
80
80
70
Convection
LOAD (%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
85
100
115
125
155
230
264
INPUT VOLTAGE (VAC) 60Hz
File Name:TP-75-SPEC 2010-10-18