TP-100 100W Triple Output with PFC Function series ■ Features : $Universal AC input / Full range $Built-in active PFC function, PF>0.94 $Protections: Short circuit / Overload / Over voltage $Free air cooling convection $Fixed switching frequency at 100KHz $3 years warranty .. SPECIFICATION TP-100A MODEL OUTPUT TP-100C TP-100D CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V 5V 24V 12V RATED CURRENT 10A 4A 0.6A 10A 4A 0.6A 10A 3A 0.6A 10A 2A 0.6A CURRENT RANGE 3 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0.4 ~ 4A 0 ~ 1A 3 ~ 15A 0.4 ~ 3A 0 ~ 1A RATED POWER (max.) 101W 105.2W 104W 105.2W RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 ± 3.0% ± 7.0% ± 6.0% ± 3.0% ± 6.0% ± 6.0% ± 3.0% +10,-6% ± 6.0% ± 3.0% ± 8.0% ± 6.0% LINE REGULATION ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% LOAD REGULATION ± 3.0% ± 6.0% ± 4.0% ± 3.0% ± 6.0% ± 4.0% ± 3.0% ± 6.0% ± 4.0% ± 3.0% ± 6.0% ± 4.0% SETUP, RISE TIME 800ms, 60ms/230VAC 24ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT TP-100B OUTPUT NUMBER Note.5 90 ~ 264VAC 800ms, 60ms/115VAC at full load 24ms/115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.94/230VAC EFFICIENCY (Typ.) 75% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 0.75A/230VAC COLD START ≦40A/230V LEAKAGE CURRENT PF>0.98/115VAC at full load 78% 77% 78% <3.5mA / 240VAC 105 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC (Note 4) NOTE 95℃ ± 5℃ (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60℃ (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH SAFETY STANDARDS ± 0.03%/℃ (0~50℃) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT OTHERS Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V on +5V Protection type : Shut down o/p voltage, re-power on to recover EMS IMMUNITY MTBF DIMENSION PACKING Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 170.1K hrs min. MIL-HDBK-217F (25℃) 199*99*50mm (L*W*H) 0.83Kg; 20pcs/17.6Kg/1.28CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:TP-100-SPEC 2007-10-25 TP-100 100W Triple Output with PFC Function Mechanical Specification Case No. 916A series Unit:mm 199 20 35 133 25 117 70 +V ADJ.2 +V ADJ.1 LED 99 16 10 49.5 119 51 79 2-M4 5-M3 L=6mm 38 7.62 9 8 7 6 5 4 3 2 1 6.15 65 15 142 25 Terminal Pin No. Assignment : Assignment Assignment Pin No. Pin No. AC/L DC OUTPUT V2 5 1 AC/N DC OUTPUT V1 2 6,7 FG DC OUTPUT COM 8,9 3 DC OUTPUT V3 4 25 12.5 50 25 8 max. 6-M4 L=6mm Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT PWM & PFC CONTROL FG RECTIFIERS & FILTER RECTIFIERS & FILTER V3 REGULATOR V2 RECTIFIERS & FILTER +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 (HORIZONTAL) 60 50 40 90 110 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:TP-100-SPEC 2007-10-25