LPP-100 100W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty SPECIFICATION MODEL OUTPUT LPP-100-3.3 LPP-100-5 LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A CURRENT RANGE 0 ~ 20A 0 ~ 20A 0 ~ 13.3A 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A RATED POWER 66W 100W 101.25W 102W 101.25W 100.5W 100.8W 102.6W 100.8W 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 600ms, 30ms/230VAC HOLD UP TIME (Typ.) 28ms/230VAC POWER FACTOR (Typ.) PF>0.95/230VAC 69% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.7A/115VAC 79% 80% 83% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 3.8 ~ 4.45V 83% 83% 5.75 ~ 6.75V 8.6 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V 55.2 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 224.3Khrs min. MIL-HDBK-217F (25 222*62*32mm (L*W*H) 0.51Kg; 24pcs/13.9Kg/1.76CUFT DIMENSION PACKING NOTE 79% OVERLOAD ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT OTHERS 76% 0.75A/230VAC COLD START 30A/230VAC <2mA / 240VAC WORKING TEMP. WORKING HUMIDITY (Note 4) PF>0.98/115VAC at full load 75% LEAKAGE CURRENT OVER VOLTAGE EMC 120 ~ 370VDC EFFICIENCY(Typ.) PROTECTION SAFETY & 1200ms, 30ms/115VAC at full load 28ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 47 ~ 63Hz FREQUENCY RANGE INPUT 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:LPP-100-SPEC 2008-03-25 LPP-100 100W Single Output with PFC Function Mechanical Specification series Unit:mm 222 212 5 5 CN1 52 62 CN2 1 5 4 3 2 1 F4A/250V 8 +V ADJ. 4- 2 max. 32 3.5 AC Input Connector (CN1) : JST B5P-VH or equivalent JST VHR or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent Terminal Mating Housing Assignment AC/L No Pin AC/N FG Pin No. 1 2,4 3 5 Pin No. 1,2,3,4 5,6,7,8 JST SVH-21T-P1.1 or equivalent Assignment -V +V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram PFC fosc : 67KHz PWM fosc : 134KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT FG O.L.P. +V -V COSTANT CURRENT LIMITING & DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage 3.3 ~ 7.5V With 18CFM (15cm) Forced Air 60 Convection 3.3V ~ 7.5V With NO FAN 12 ~ 48V With No FAN 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 90 80 70 LOAD (%) 80 LOAD (%) 100 Forced Air 100 60 50 40 85 100 115 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:LPP-100-SPEC 2008-03-25