VECTRON TFS150G3

tfs150g3.doc
Version 2.1
VI TELEFILTER
Filter Specification
18.10.2002
TFS 150G3
1/3
1. Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances at fc:
23 °C
0 dBm
for input:
for output:
Q-value of matching elements:
67 Ω  - 3,07 pF. (typical)
56 Ω  - 22,1 pF. (typical)
30
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS150G3 is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 22,5 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for
the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the
operating temperature range is not included in the production tolerance scheme.
Data
typ. value
Insertion loss (Reference level)
ae
28
Reference frequency fc at ambient temperature (fCTA)
tolerance / limit
dB
max 30
150,25 MHz
Pass band ( PB ) at ambient temperature TA:
dB
150,25 ± 0,075
MHz
fC - 14,80 MHz.....fC + 14,80
Amplitude ripple in PB (p-p):
0,9
dB
max. 1,0
MHz
dB
Bandwidth at ambient temperature:
1,5
3
22,5
30
dB - band width
dB - band width
dB - band width
dB - band width
30,05
30,16
30,77
31,20
Relative attenuation
fc
fc
fc
fc
fc
fc
±
±
+
-
14,8
15,4
16
16
120
MHz
MHz
MHz
MHz
min. 30,00
MHz
max. 30,80
max. 32,00
MHz
MHz
arel
MHz
MHz
MHz
MHz
MHz
fc
fc
fc
fc
fc
fc
±
±
±
+
-
14,8
14,99
16,0
150
120
145
MHz
MHz
MHz
MHz
MHz
MHz
Group delay ( mean value in PB ): 2,5
Group delay ripple in PB (p-p):
Deviation from linear phase in PB :
Triple transit attenuation compared to main signal
Crosstalk
Substrate material
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature
24
50...55
45...50
55...70
dB
dB
dB
dB
µs
max 3
80
ns
max. 1,0
max. 1,5
min. 22,5
min. 30
min. 30
min. 30
dB
dB
dB
dB
dB
dB
µs
max. 180
ns
8° p-p...(1,5 ° r.m.s.)
62
57
dB
dB
LiNbO3
-87
-94
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
Operating temperature range
- 25 °C ... + 80 °C
Storage temperature range
- 40 °C ... + 85 °C
Generated:
Dunzow W.P.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs150g3.doc
Version 2.1
VI TELEFILTER
Filter Specification
TFS 150G3
18.10.2002
2/3
Construction and pin connection
(All dimensions in mm)
TFS 150G3
TFS71
E
tft
LN
tft
L8
Pin 1
Pin 14
Pin 8
Pin 7
Pin 2,9
Input
Input RF Return
Output
Output RF Return
Pakage Ground
50 Ω - Matching network:
1 2
L1
C1
L2
C3
C2
14
C1 , L1 , C3 ;
7
9
8
C2 , L2 - to see Application Note.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs150g3.doc
Version 2.1
VI TELEFILTER
Filter Specification
18.10.2002
TFS 150G3
3/3
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.