TFS 70 G - Page 1 / 3
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
Input power level:
Source impedance:
Load impedance:
23 °C
0 dBm
50 Ω and test adapter
50 Ω and test adapter
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 70 G is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the
3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 70,00 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________
22
dB
ae
Insertion loss
(Reference level)
______________________________________________________________________________________________________
70,0
MHz
fN
Nominal frequency
______________________________________________________________________________________________________
70,0
MHz
Centre frequency
fo
_____________________________________________________________________________________________________
Pass band
fN - 100 kHz ... fN + 100 kHz
______________________________________________________________________________________________________
Relative attenuation
fN ±
arel
40 MHz ... fN ± 57 MHz
-
min. 45
dB
fN ±
83 MHz ... fN ± 100 MHz
min 45
dB
______________________________________________________________________________________________________
Group delay
GD
Absolute delay fN - 65 MHz ... fN + 75 MHz
2
µs
max 2,15 µs
______________________________________________________________________________________________________
- 72
ppm/K²
TCf *)
Temperature coefficient of frequency
______________________________________________________________________________________________________
-5
°C
Frequency inversion temperature
To
______________________________________________________________________________________________________
Operating temperature range
- 20 °C ... + 85 °C
Storage temperature range
- 40 °C ... + 85 °C
______________________________________________________________________________________________________
12
V
Permissible DC voltage VDC
10
V
Permissible AC voltage Vpp
______________________________________________________________________________________________________
*) ∆f(Hz) = TCf(ppm/K²) x (∆T)² x fTo(MHz)
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
______________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs70g.doc
version 1.0
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 70 G - Page 2 / 3
______________________________________________________________________________________________________
Construction, pin connection and 50 Ω matching network
(All dimensions in mm)
1
2
3
4
Input GND
GND
GND
Output
5
6
7
8
Output GND
GND
GND
Input
TFS 70 G
L3
L1 = 495 nH
L3 = 510 nH
L2 = 375 nH
L4 = 395 nH
Air reflow temperature conditions
1st and 2nd air reflow profile
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
______________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs70g.doc
version 1.0
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 70 G - Page 3 / 3
______________________________________________________________________________________________________
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
______________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information