Measurement condition :
23
°C
0
dBm.
for input: 50
for output: 50
Ambient temperature TA:
Input power level:
Terminating impedances at fc :
2.
0 pF.
0 pF.
Characteristics :
Remark:
Reference level for the relative attenuation arel of the TFS 36D is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae . The centre frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 40 dB filter attenuation level relative to the insertion loss ae . The nominal frequency fN is fixed on 36 MHz without tolerance.
The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter.
Data
typ. value
Insertion loss (Reference level)
Nominal frequency :
ae
fN at temperature TOT = 45°C
Centre frequency fc at ambient temperature TA (fCAT)
tolerance / limit
max.
25,9
dB
36,0
MHz
36,06
MHz
Pass band ( PB ) at operating temperature TOT = 45°C :
30 dB
36 MHz
fN - 2,6 MHz ... fN + 2,6 MHz
Amplitude ripple in PB (p-p) :
0,45
dB
max.
0,75
dB
Amplitude ripple in any 1 MHz increment within 90% of the PB :
0,35
dB
max.
0,4
dB
0,75 dB - band width
1 dB - band width
3 dB - band width
5,80
5,90
6,17
MHz
MHz
MHz
min.
min.
5,20
5,80
MHz
MHz
40 dB - band width
45 dB - band width
55 dB - band width
7,16
7,21
7,29
MHz
MHz
MHz
max.
max.
7,25
8,00
MHz
MHz
max.
max.
0,75
1,0
dB
dB
Bandwidth
at operating temperature T OT = 45°C :
Relative attenuation
arel
fN ..... fN ±
MHz ... fN ±
2,6 MHz
2,9 MHz
-
fN ± 3,625 MHz ... fN ±
4,0 MHz
fN - 26,0
MHz ... fN 4,0 MHz
fN + 4,0
MHz ... fN + 34,2 MHz
55
55
55
dB
dB
dB
min.
min.
min.
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
3,15
50
µs
ns
max.
5,0
max. 150
µs
ns
Deviation from linear phase in PB (p-p):
Triple transit attenuation compared to main signal :
Crosstalk :
1,8 °
61
dB
70
dB
max.
p-p
fN ±
2,6
Temperature coefficient of frequency ( Tc f )
Frequency deviation of fc over temperature
Operating temperature
Storage temperature range
2°
dB
dB
dB
-75 ppm/K
fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
+ 45 °C
- 25 °C ... + 85 °C
Generated:
Dunzow W.P.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
40
45
45
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 36D.doc
Version 1.3
VI TELEFILTER
Filter Specification
TFS 36 D
20.09.2001
2/5
3. Package :
35 Max
TFS
tft
20,5 Max
Datecode:
L
M
N
.......
36 D
N24
Year+week
1999
2000
2001
..........
5,5
5,5
1
12
24
13
15,24
2,54
4. 50
Pin 3
Pin 2
Pin 15
Pin 14
Pin 1, 4-12, 13, 16-24
Input
Input RF Return
Output
Output RF Return
Ground
11x2,54 = 27,94
matching network :
50
1 2 3
10 11 12
50
24 23 22
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
15 14 13
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 36D.doc
Version 1.3
VI TELEFILTER
Filter Specification
TFS 36 D
20.09.2001
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 36D.doc
Version 1.3
VI TELEFILTER
Filter Specification
20.09.2001
TFS 36 D
4/5
6. Air reflow temperature conditions :
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 36D.doc
Version 1.3
VI TELEFILTER
Filter Specification
20.09.2001
TFS 36 D
5/5
7. History :
Version Reason of Changes
Name
Date
1.0
- generate specification according to customer requirements.
Pfeiffer
14.06.2001
1.1
- amplitude ripple in passband added.
- relative attenuation fN ± 2,60 MHz changed to max. 0,75 dB
Pfeiffer
26.06.2001
1.2
- change operating temperature : from T = 40°C to T = 45°C .
- add amplitude ripple in any 1 MHz increment within 90% of the PB .
Dunzow W.
11.07.2001
1.3
- change from development specification to filter specification.
- add typical values.
Dunzow W.
20.09.2001
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.