TFS 36D.doc Version 1.3 VI TELEFILTER 1. Filter Specification 20.09.2001 TFS 36 D 1/5 Measurement condition : 23 °C 0 dBm. for input: 50 for output: 50 Ambient temperature TA: Input power level: Terminating impedances at fc : 2. 0 pF. 0 pF. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS 36D is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 40 dB filter attenuation level relative to the insertion loss ae . The nominal frequency fN is fixed on 36 MHz without tolerance. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter. Data typ. value Insertion loss (Reference level) Nominal frequency : ae fN at temperature TOT = 45°C Centre frequency fc at ambient temperature TA (fCAT) tolerance / limit max. 25,9 dB 36,0 MHz 36,06 MHz Pass band ( PB ) at operating temperature TOT = 45°C : 30 dB 36 MHz fN - 2,6 MHz ... fN + 2,6 MHz Amplitude ripple in PB (p-p) : 0,45 dB max. 0,75 dB Amplitude ripple in any 1 MHz increment within 90% of the PB : 0,35 dB max. 0,4 dB 0,75 dB - band width 1 dB - band width 3 dB - band width 5,80 5,90 6,17 MHz MHz MHz min. min. 5,20 5,80 MHz MHz 40 dB - band width 45 dB - band width 55 dB - band width 7,16 7,21 7,29 MHz MHz MHz max. max. 7,25 8,00 MHz MHz max. max. 0,75 1,0 dB dB Bandwidth at operating temperature T OT = 45°C : Relative attenuation arel fN ..... fN ± MHz ... fN ± 2,6 MHz 2,9 MHz - fN ± 3,625 MHz ... fN ± 4,0 MHz fN - 26,0 MHz ... fN 4,0 MHz fN + 4,0 MHz ... fN + 34,2 MHz 55 55 55 dB dB dB min. min. min. Group delay ( mean value in PB ): Group delay ripple in PB (p-p): 3,15 50 µs ns max. 5,0 max. 150 µs ns Deviation from linear phase in PB (p-p): Triple transit attenuation compared to main signal : Crosstalk : 1,8 ° 61 dB 70 dB max. p-p fN ± 2,6 Temperature coefficient of frequency ( Tc f ) Frequency deviation of fc over temperature Operating temperature Storage temperature range 2° dB dB dB -75 ppm/K fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) + 45 °C - 25 °C ... + 85 °C Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] 40 45 45 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 36D.doc Version 1.3 VI TELEFILTER Filter Specification TFS 36 D 20.09.2001 2/5 3. Package : 35 Max TFS tft 20,5 Max Datecode: L M N ....... 36 D N24 Year+week 1999 2000 2001 .......... 5,5 5,5 1 12 24 13 15,24 2,54 4. 50 Pin 3 Pin 2 Pin 15 Pin 14 Pin 1, 4-12, 13, 16-24 Input Input RF Return Output Output RF Return Ground 11x2,54 = 27,94 matching network : 50 1 2 3 10 11 12 50 24 23 22 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] 15 14 13 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 36D.doc Version 1.3 VI TELEFILTER Filter Specification TFS 36 D 20.09.2001 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow):max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 36D.doc Version 1.3 VI TELEFILTER Filter Specification 20.09.2001 TFS 36 D 4/5 6. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 36D.doc Version 1.3 VI TELEFILTER Filter Specification 20.09.2001 TFS 36 D 5/5 7. History : Version Reason of Changes Name Date 1.0 - generate specification according to customer requirements. Pfeiffer 14.06.2001 1.1 - amplitude ripple in passband added. - relative attenuation fN ± 2,60 MHz changed to max. 0,75 dB Pfeiffer 26.06.2001 1.2 - change operating temperature : from T = 40°C to T = 45°C . - add amplitude ripple in any 1 MHz increment within 90% of the PB . Dunzow W. 11.07.2001 1.3 - change from development specification to filter specification. - add typical values. Dunzow W. 20.09.2001 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.