tfs87.doc Version 1.2 06.01.02 __________________________________________________________________________________ VI TELEFILTER Filter specification TFS 87 1/3 __________________________________________________________________________________ 1. Measurement condition Package, pin connection and 50 Ω matching network. see page 2. Ambient temperature TA: 23 °C Input power level: 0 dBm (typ.) Max 10 dBm. Terminating impedances at fc: for input: 256 Ω - 22,5 pF. for output: 703 Ω - 11,8 pF. 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 87 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. Data typ. value tolerance / limit ___________________________________________________________________________________________________ 22 dB max 25 dB Insertion loss (Reference level) ae ___________________________________________________________________________________________________ Reference frequency fc at ambient temperature (fCAT) 87.10 MHz 87.10 ± 0.2 MHz ___________________________________________________________________________________________________ Relative frequency distance of fCAT within one set of 3 filters 21200 kHz *) max ± 20 kHz 1st filter with fCAT = 65,9 MHz ± 200 kHz *) 2nd filter with fCOT = 75,3 MHz ± 200 kHz 11800 kHz max ± 20 kHz ___________________________________________________________________________________________________ 1 dB - band width 2.35 MHz 3 dB - band width 2.47 MHz 20 dB - band width 2.77 MHz 40 dB - band width 2.93 MHz ___________________________________________________________________________________________________ Amplitude ripple (p-p): fc ... fc ± 1.1 MHz 0.7 dB max 1.0 dB ___________________________________________________________________________________________________ Relative attenuation arel fc fc ± 1.1 MHz max 1 dB fc ± 1.1 MHz fc ± 1.2 MHz max 3 dB fc ± 1.5 MHz 42 dB min 40 dB In the frequency range fc ± 1,5 MHz ... fc ± 25 MHz the limit line is of type SLOPING LINE. fc ± 25 MHz 65 dB min 50 dB fc ± 25 MHz fc ± 50 MHz 70 dB ___________________________________________________________________________________________________ Group delay 4.87 µs max 5.0 µs ___________________________________________________________________________________________________ Group delay ripple (p-p): fc ... fc ± 1.2 MHz ± 80 ns ± max 150 ns ___________________________________________________________________________________________________ Deviation from linear phase (p-p): fc ... fc ± 1.0 (1.2) MHz 2° (6°) ___________________________________________________________________________________________________ Triple transit attenuation compared to main signal 50 dB ___________________________________________________________________________________________________ Input/Output return loss with matching network (S11/S22): 4/4 dB ___________________________________________________________________________________________________ Crosstalk 60 dB ___________________________________________________________________________________________________ Substrate material Quartz ___________________________________________________________________________________________________ Frequency inversion temperature ( To ) 5° ____________________________________________________________________________________________________________________________________________________________________________________________________________ Temperature coefficient of frequency ( Tcf ) -0.0306 ppm/K² ____________________________________________________________________________________________________________________________________________________________________________________________________________ Frequency deviation of fc over temperature ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fCAT (MHz) ____________________________________________________________________________________________________________________________________________________________________________________________________________ Operating temperature range - 25 °C ... + 80 °C Storage temperature range - 40 °C ... + 85 °C ___________________________________________________________________________________________________ *) For the 2nd filter fCOT is its reference frequency fC at the operation temperature OT = 70 °C ± 1 °C. The reference frequency at ambient temperature fCAT for this 2nd filter and the from it resulting relative frequency distance have to be determined. Generated: Checked/Approved: Weinberg Dr. Bert Wall ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information tfs87.doc Version 1.2 06.01.02 __________________________________________________________________________________ VI TELEFILTER Filter specification TFS 87 2/3 __________________________________________________________________________________ 3. Package 24 13 35 Max Pin 2 Pin 3 Pin 14 Pin 15 TFS 87 20.5 Max tft L1 1 5.5 Input Input RF Return Output Output RF Return 12 5.5 Max 15.24 1 12 24 13 2.54 11x2.54=27.94 4. 50 Ω matching network: 1 2 3 4 11 12 L2 C1 L1 C2 24 16 15 14 13 C1 = 47 pF. L1 = 170 ± 5 nH. C2 = 39 pF. L2= 275 ± 5 nH. ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information tfs87.doc Version 1.2 06.01.02 __________________________________________________________________________________ VI TELEFILTER Filter specification TFS 87 3/3 __________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information