VECTRON TFS87

tfs87.doc
Version 1.2
06.01.02
__________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 87
1/3
__________________________________________________________________________________
1. Measurement condition
Package, pin connection and 50 Ω matching network.
see page 2.
Ambient temperature TA:
23 °C
Input power level:
0 dBm (typ.)
Max 10 dBm.
Terminating impedances at fc: for input:
256 Ω  - 22,5 pF.
for output:
703 Ω  - 11,8 pF.
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 87 is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 20 dB filter attenuation level relative to the insertion loss ae.
Data
typ. value
tolerance / limit
___________________________________________________________________________________________________
22
dB
max 25
dB
Insertion loss (Reference level) ae
___________________________________________________________________________________________________
Reference frequency fc at ambient temperature (fCAT)
87.10
MHz
87.10 ± 0.2
MHz
___________________________________________________________________________________________________
Relative frequency distance of fCAT within one set of 3 filters
21200
kHz *)
max ± 20
kHz
1st filter with fCAT = 65,9 MHz ± 200 kHz *)
2nd filter with fCOT = 75,3 MHz ± 200 kHz
11800
kHz
max ± 20
kHz
___________________________________________________________________________________________________
1 dB - band width
2.35
MHz
3 dB - band width
2.47
MHz
20 dB - band width
2.77
MHz
40 dB - band width
2.93
MHz
___________________________________________________________________________________________________
Amplitude ripple (p-p):
fc ... fc ± 1.1 MHz
0.7
dB
max 1.0
dB
___________________________________________________________________________________________________
Relative attenuation
arel
fc
fc ± 1.1 MHz
max 1
dB
fc ± 1.1 MHz
fc ± 1.2 MHz
max 3
dB
fc ± 1.5 MHz
42
dB
min 40
dB
In the frequency range fc ± 1,5 MHz ... fc ± 25 MHz the limit line is of type SLOPING LINE.
fc ± 25
MHz
65
dB
min 50
dB
fc ± 25
MHz
fc ± 50
MHz
70
dB
___________________________________________________________________________________________________
Group delay
4.87
µs
max 5.0
µs
___________________________________________________________________________________________________
Group delay ripple (p-p):
fc ... fc ± 1.2 MHz
± 80
ns
± max 150
ns
___________________________________________________________________________________________________
Deviation from linear phase (p-p): fc ... fc ± 1.0 (1.2) MHz
2° (6°)
___________________________________________________________________________________________________
Triple transit attenuation compared to main signal
50
dB
___________________________________________________________________________________________________
Input/Output return loss with matching network (S11/S22):
4/4
dB
___________________________________________________________________________________________________
Crosstalk
60
dB
___________________________________________________________________________________________________
Substrate material
Quartz
___________________________________________________________________________________________________
Frequency inversion temperature ( To )
5°
____________________________________________________________________________________________________________________________________________________________________________________________________________
Temperature coefficient of frequency ( Tcf )
-0.0306
ppm/K²
____________________________________________________________________________________________________________________________________________________________________________________________________________
Frequency deviation of fc over temperature
∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fCAT (MHz)
____________________________________________________________________________________________________________________________________________________________________________________________________________
Operating temperature range
- 25 °C ... + 80 °C
Storage temperature range
- 40 °C ... + 85 °C
___________________________________________________________________________________________________
*) For the 2nd filter fCOT is its reference frequency fC at the operation temperature OT = 70 °C ± 1 °C. The reference frequency
at ambient temperature fCAT for this 2nd filter and the from it resulting relative frequency distance have to be determined.
Generated:
Checked/Approved:
Weinberg
Dr. Bert Wall
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs87.doc
Version 1.2
06.01.02
__________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 87
2/3
__________________________________________________________________________________
3. Package
24
13
35 Max
Pin 2
Pin 3
Pin 14
Pin 15
TFS 87
20.5 Max
tft
L1
1
5.5
Input
Input RF Return
Output
Output RF Return
12
5.5 Max
15.24
1
12
24
13
2.54
11x2.54=27.94
4. 50 Ω matching network:
1 2 3 4
11 12
L2
C1
L1
C2
24
16 15 14 13
C1 = 47 pF.
L1 = 170 ± 5 nH.
C2 = 39 pF.
L2= 275 ± 5 nH.
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs87.doc
Version 1.2
06.01.02
__________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 87
3/3
__________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information