Filename: tfs 433v.doc Version 1.1 VI TELEFILTER 24.01.2005 Filter specification TFS 433V 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 240 Ω || -2,5 pF 240 Ω || -2,5 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 433V is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 433,92 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae = amin Insertion loss (reference level) 1,78 Nominal frequency fN - Centre frequency 3dB fC 433,92 max. 0,16 0,18 0,22 fN 423,92 19,92 fN 10,42 fN 2,20 fN 1,80 fN 1,00 fN + 8,08 fN + 66,08 fN + 266,08 fN + 371,08 fN + DV voltage 3,0 433,92 MHz dB MHz fN ± 0,16 MHz Arel Relative attenuation - dB PB Passband fN fN fN tolerance / limit MHz … fN MHz … fN MHz … fN + + + 0,16 0,18 0,22 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz + + + + + 19,92 10,42 2,20 1,80 0,82 8,08 66,08 266,08 371,08 566,08 … … … … … … … … … … fN fN fN fN fN fN fN fN fN fN MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz VDC OTR Storage temperature range Temperature coefficient of frequency dB dB dB max. max. max. 2 3 6 dB dB dB 58 56 46 46 18 40 47 65 52 62 - dB dB dB dB dB dB dB dB dB dB min. min. min. min. min. min. min. min. min. min. max. 52 48 29 26 17 18 40 50 45 60 6 dB dB dB dB dB dB dB dB dB dB V max. 10 dBm - Input power level Operating temperature range 0.45 0.50 0.70 TCf ** - - 40 °C ... + 95°C - - 45 °C ... + 120°C -0,03 ppm/K 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 433v.doc Version 1.0 VI TELEFILTER 13.09.2004 Development specification TFS 433V 2/5 0 0 -10 -0.5 -20 -1 -30 -1.5 magnitude in dB magnitude in dB Filter characteristic -40 -50 -60 -2 -2.5 -3 -70 -3.5 -80 -4 -90 -4.5 -100 300 400 500 600 700 frequency in MHz 800 900 1000 -5 433.6 433.7 433.8 433.9 434 frequency in MHz 434.1 434.2 Construction and pin connection (All dimensions in mm) 7 +0,20 SQ 3,81 - 0,10 5 433V ● T05 1 3 7 5 Input RF Return Input Ground Ground Output Output RF Return Ground Ground Date code: T U V ... Year + week 2005 2006 2007 1,2 Max. 0,1 12 0° 0,6 3 1,78 2,54 1 Date code 1 2 3 4 5 6 7 8 1,78 50 Ohm Test circuit L1 2 1 5 SAW L2 6 3,4,7,8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 433v.doc Version 1.0 VI TELEFILTER 13.09.2004 Development specification TFS 433V 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 t Po PIN Marker P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 433v.doc Version 1.0 VI TELEFILTER 13.09.2004 Development specification TFS 433V 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 433v.doc VI TELEFILTER Version 1.0 Development specification 13.09.2004 TFS 433V 5/5 Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 13.09.2004 1.1 - Filter specification, add of typical values Noack 24.01.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.