Filename: tfs 325c.doc Version 1.6 VI TELEFILTER 22.08.2006 Filter specification TFS 325C 1/5 unMeasurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 84 Ω || -20,1 pF 112 Ω || -16,6 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 325C is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 325 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae fN - PB - Nominal frequency Passband Pass band ripple Relative attenuation fN fN fN fN fN fN fN fN fN fN fN ± ± ± + + + + + 7,5 12 13 315 105 25 30 50 55 80 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz 12 dB tolerance / limit max. 14 325 fN 0,22 dB max. ± dB MHz 5 MHz 1 dB arel … fN ± 5 MHz 1,2 dB max. 2 dB … … … … … … … … … … ± ± ± + + + + + 12 13 25 105 25 30 50 55 80 175 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz 4,5 40 52 65 52 45 40 45 40 50 dB dB dB dB dB dB dB dB dB dB min. min. min. min. min. min. min. min. min. min. 3 30 40 50 45 40 35 40 35 40 dB dB dB dB dB dB dB dB dB dB µs max. 1 µs ns max. 75 ns fN fN fN fN fN fN fN fN fN fN Group delay within PB 0,32 Group delay ripple within PB 20 Phase linearity within PB Operating temperature range 4,1 OTR Storage temperature range Temperature coefficient of frequency TCf ** deg - - - 40 °C ... + 85°C - - 40 °C ... + 85°C -18 ppm/K - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 325c.doc Version 1.6 VI TELEFILTER 22.08.2006 Filter specification TFS 325C 2/5 0 0.85 -1 0.79 -14 -2 0.73 -21 -3 0.67 -28 -4 0.61 -5 0.55 -6 0.49 -49 -7 0.43 -56 -8 0.37 -63 -9 0.31 -35 -42 -70 Construction and pin285connection 225 245 265 305 325 345 365 385 405 425 -10 317 318.6 320.2 321.8 frequency in MHz 323.4 325 326.6 frequency in MHz 328.2 329.8 331.4 delay in µs 0 -7 magnitude in dB magnitude in dB Filter characteristic 0.25 333 (All dimensions in mm) Construction and pin connection (All dimensions in mm) S 325C ● U29 3 Date code 2 Max. 1 Ground Ground Input Input RF Return or Input Ground Ground Ground Ground Output Output RF Return or Output Ground Ground Date code: U V W ... Year + week 2006 2007 2008 1 5,2 Max. 2,54 ±0,2 7,2 Max. 2,54 ±0,2 1 1 2 3 4 5 6 7 8 9 10 11 12 0,80 50 Ω Test circuit 9 L1 10 C1 3 SAW L2 L3 4 L4 C2 1, 2, 5, 6, 7, 8, 11, 12 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 325c.doc Version 1.6 VI TELEFILTER 22.08.2006 Filter specification TFS 325C 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 325c.doc Version 1.6 VI TELEFILTER 22.08.2006 Filter specification TFS 325C 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 325c.doc VI TELEFILTER Version 1.6 Filter specification 22.08.2006 TFS 325C 5/5 History Version Reason of Changes Name Date 1.0 Generation of development specification Alawneh 15.05.2006 1.1 Pinning modified Alawneh 06.06.2006 1.2 Add 40 dB rejection level Strehl 14.06.2006 1.3 Change data Strehl 30.06.2006 1.4 - terminating impedances, typical values, filter characteristics and matching configuration added - limits of relative attenuations changed Pfeiffer 20.07.2006 1.5 - correct pin connection and test circuit Noack 02.08.2006 1.6 - test circuit corrected Pfeiffer 22.08.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.