tfs70N.doc Version 1.6 VI TELEFILTER Filter specification 01.04.99 TFS 70 N 1. Measurement condition Package, pin connection and 50 Ω matching network Ambient temperature TA: Input power level: Terminating impedances in fc: 23 °C 0 dBm. for input: 56,8 Ω - 40,8 pF. for output: 46,5 Ω - 35,3 pF. ( see Application Note) 1/3 (see page 2.) [ 27,9 Ω + j 28,4 Ω] [ 30,6 Ω + j 22,0 Ω] 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 70N is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme. Data typ. value Insertion loss (Reference level) Reference frequency ae 20,6 fc at ambient temperature (fCAT) : 70 tolerance / limit dB max 24 MHz 70 ± 0,1 dB MHz fC - 4,8 MHz ... fC + 4,8 MHz Pass band (-2 dB) : Bandwidth at ambient temperature: 1,0 1,5 2,0 3,0 20 35 45 50 dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width Amplitude ripple (p-p): 9,92 9,94 9,98 10,12 10,60 10,77 10,843 10,900 fc ... fc ± 4,8 MHz Relative attenuation fc fc ± 4,8 MHz fc ± 5,4 MHz fc ± 5,6 MHz fc ± 6,0 MHz Group delay inpass band: MHz MHz MHz MHz MHz MHz MHz MHz min. 9,6 min. 10,0 MHz MHz min. 10,8 min. 11,2 MHz MHz 0,7 dB max 2 dB 40 55 55...65 3,74 dB dB dB µs max 2 max 3 min 35 min 45 min 50 max 4,5 dB dB dB dB dB µs 140 ns max 200 ns arel ... ... ... ... ... Group delay ripple (p-p): fc fc fc fc fc ± ± ± ± ± 4,8 5,0 5,6 6,0 35 MHz MHz MHz MHz MHz fc ... fc ± 4,8 MHz Deviation from linear phase (p-p): fc ... fc ± 5,0 MHz 5,5° Crosstalk attenuation compared to main signal 70 dB Triple transit attenuation compared to main signal 50 dB Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature Operating temperature range Storage temperature range -87 ppm/K -94 ppm/K ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) 0 °C ... + 60 °C - 20 °C ... + 85 °C Generated: Wadim P. Dunzow Checked/Approved: Dr. Bert Wall VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70N.doc Version 1.6 VI TELEFILTER Filter specification 01.04.99 TFS 70 N 2/3 3. Package 35 Max Pin 23 Pin 24 Pin 11 Pin 12 Pin 1-10, 13-22 TFS 70 N tft L3 20,5 Max Input Input RF Return Output Output RF Return Ground 5,5 5,5 1 12 24 13 15,24 2,54 11x2,54 = 27,94 4. 50 Ω matching network: 1 11 12 L2 L3* C1* L1 24 23 13 L1 = 125 nH L2 = 60 nH C1 = 27 pF. *) L3 ≈ 85 ± 5 nH. L3 : L 3 C 1 = 2 π f1 , f 1 = 94,3 ± 0,3 MHz VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70N.doc Version 1.6 VI TELEFILTER Filter specification 01.04.99 TFS 70 N 3/3 5. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.