VECTRON TFS70N

tfs70N.doc
Version 1.6
VI TELEFILTER
Filter specification
01.04.99
TFS 70 N
1. Measurement condition
Package, pin connection and 50 Ω matching network
Ambient temperature TA:
Input power level:
Terminating impedances in fc:
23 °C
0
dBm.
for input:
56,8 Ω  - 40,8 pF.
for output:
46,5 Ω  - 35,3 pF.
( see Application Note)
1/3
(see page 2.)
[ 27,9 Ω + j 28,4 Ω]
[ 30,6 Ω + j 22,0 Ω]
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 70N is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at
the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference
frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature
range is not included in the production tolerance scheme.
Data
typ. value
Insertion loss (Reference level)
Reference frequency
ae
20,6
fc at ambient temperature (fCAT) :
70
tolerance / limit
dB
max 24
MHz
70 ± 0,1
dB
MHz
fC - 4,8 MHz ... fC + 4,8 MHz
Pass band (-2 dB) :
Bandwidth at ambient temperature:
1,0
1,5
2,0
3,0
20
35
45
50
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
Amplitude ripple (p-p):
9,92
9,94
9,98
10,12
10,60
10,77
10,843
10,900
fc ... fc ± 4,8 MHz
Relative attenuation
fc
fc ± 4,8 MHz
fc ± 5,4 MHz
fc ± 5,6 MHz
fc ± 6,0 MHz
Group delay inpass band:
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
min. 9,6
min. 10,0
MHz
MHz
min. 10,8
min. 11,2
MHz
MHz
0,7
dB
max 2
dB
40
55
55...65
3,74
dB
dB
dB
µs
max 2
max 3
min 35
min 45
min 50
max 4,5
dB
dB
dB
dB
dB
µs
140
ns
max 200
ns
arel
...
...
...
...
...
Group delay ripple (p-p):
fc
fc
fc
fc
fc
±
±
±
±
±
4,8
5,0
5,6
6,0
35
MHz
MHz
MHz
MHz
MHz
fc ... fc ± 4,8 MHz
Deviation from linear phase (p-p): fc ... fc ± 5,0 MHz
5,5°
Crosstalk attenuation compared to main signal
70
dB
Triple transit attenuation compared to main signal
50
dB
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature
Operating temperature range
Storage temperature range
-87
ppm/K
-94
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
0 °C ... + 60 °C
- 20 °C ... + 85 °C
Generated:
Wadim P. Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs70N.doc
Version 1.6
VI TELEFILTER
Filter specification
01.04.99
TFS 70 N
2/3
3. Package
35 Max
Pin 23
Pin 24
Pin 11
Pin 12
Pin 1-10, 13-22
TFS 70 N
tft
L3
20,5 Max
Input
Input RF Return
Output
Output RF Return
Ground
5,5
5,5
1
12
24
13
15,24
2,54
11x2,54 = 27,94
4. 50 Ω matching network:
1
11 12
L2
L3*
C1*
L1
24 23
13
L1 = 125 nH
L2 = 60 nH
C1 = 27 pF.
*) L3 ≈ 85 ± 5 nH. L3 :
L 3 C 1 = 2 π f1 ,
f
1
= 94,3 ± 0,3 MHz
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs70N.doc
Version 1.6
VI TELEFILTER
Filter specification
01.04.99
TFS 70 N
3/3
5. Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.