tfs70f1.doc Version 2.4 VI TELEFILTER 1. Filter Specification 09.04.2001 TFS 70 F1 1/5 Measurement condition : Ambient temperature TA: Input power level: Terminating impedances at fc: 25 °C 0 dBm. for input: for output: 56 Ω -30 pF. 56 Ω -30 pF. 2. Characteristics : Remark: Reference level for the relative attenuation arel of the TFD 70F1 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme. Data typ. value Insertion loss (Reference level) ae Reference frequency fc at ambient temperature (fCTA) tolerance / limit 22,5 dB max. 70 70 ± 0,10MHz MHz Pass band ( PB ) at ambient temperature TA: 0,5 dB Bandwidth at ambient temperature : 1 dB - band width 3 dB - band width 40 dB - band width 45 dB - band width 50 dB - band width fc fc fc fc fc fc fc fc ± 6,1 ± 6,2 arel MHz MHz ± ± ± ± ± ± MHz*) MHz*) MHz MHz MHz*) MHz 6,8 7,2 8 10,2 18,2 35 max. 1,0dB 12,24 12,45 MHz MHz min. min. 12,2 MHz 12,4 MHz 13,23 13,30 13,32 MHz MHz MHz max. 13,3 MHz 45 48 52 55 45 45 max. max. 1 3 dB dB dB dB dB dB dB dB min. min. min. min. min. min. 40 45 48 50 40 40 dB dB dB dB dB dB max. 4,5 µs max. 200 ns Group delay ( mean value in PB ) Group delay ripple (p-p): fc ... fc ± 6 MHz Deviation from linear phase (p-p): fc ... fc ± 6 MHz 4,1 100 7,5° µs ns (p-p) Triple transit attenuation compared to main signal Input/Output return loss with matching network (S11/S22): Crosstalk 52 4 / 3,5 65 dB dB dB Substrate material Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature Operating temperature range Storage temperature range dB fC - 6,1 MHz .... fC + 6,1 MHz Amplitude ripple in PB (p-p): Relative attenuation fc ..... fc ± 6,1 MHz fc ± 6,65 MHz fc ± 6,8 MHz fc ± 7,2 MHz fc ± 8 MHz fc ± 10,2 MHz fc ± 18,2 MHz 25 LiNbO3 -86 ppm/K -94 ppm/K ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz) - 25 °C ... + 80 °C - 40 °C ... + 85 °C *) in this frequency range the limit line is of type SLOPING LINE Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70f1.doc Version 2.4 VI TELEFILTER Filter Specification TFS 70 F1 09.04.2001 2/5 3. Package : 35 Max TFS tft 20,5 Max 70F1 N08 Datecode: L M N .... Year+week 1999 2000 2001 ........ 5,5 5,5 1 12 24 13 Pin 23 Input Pin 24 Input RF return Pin 11 Output Pin 12 Output RF return Pin 4-9, 16-21 Package ground Pin 1-3, 10, 13-15, 22 Dummy 15,24 2,54 11x2,54 = 27,94 4. 50 Ω matching network: 1 11 12 L2 L1 24 23 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] 13 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70f1.doc Version 2.4 VI TELEFILTER Filter Specification 09.04.2001 TFS 70 F1 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70f1.doc Version 2.4 VI TELEFILTER Filter Specification 09.04.2001 TFS 70 F1 4/5 6. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 °C - 170 °C over 200 °C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs70f1.doc Version 2.4 VI TELEFILTER Filter Specification TFS 70 F1 09.04.2001 5/5 7. History : Version Reason of Changes Name Date 2.4 Generate filter specification in actually format. - change package; - add ” 5. Sability characteristics ”; Dunzow W. 09.04.2001 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 Email: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.