File name: Tfs140K.doc version 1.1 VI TELEFILTER 1. Filter specification 26.02.2002 TFS 140K 1/5 Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc : 2. 45 °C 0 dBm for input: for output: 50 Ω 0 pF. 50 Ω 0 pF. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS 140K is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed at 140 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 6 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value Insertion loss : (Reference level) tolerance / limit ae 28 Nominal frequency at 45°C : fN 140 MHz Centre frequency at 45°C * ): fCTA 140 MHz Pass band : Amplitude ripple in PB (p-p) : PB ∆α Bandwidth at ambient temperature : 1 dB - band width 1 dB - band width B1dB B1dB 45,50 45,50 MHz MHz min. max. 45 46 MHz MHz 3 dB - band width 3 dB - band width B3dB B3dB 48,28 48,28 MHz MHz min. max. 48 49 MHz MHz 40 dB - band width B40dB 59,80 MHz max. 60 MHz Relative attenuation at ambient temperature : fN - 21 MHz .... fN + 21 MHz MHz .... fN ± 22,5 MHz fN ± 21 MHz .... fN ± 24,5 MHz fN ± 23 0,2 140 dB MHz 140,000 ± 0,250 MHz fN - 21 MHz ... fN + 21 MHz max. 0,6 dB dB max. max. min. 0,6 1 1 dB dB dB max. min. 3 3 dB dB dB dB min. min. 40 36 dB dB 0,75 µs 8...12 ns 2,1°...2,8° max. 2 µs max. 4 degree min. 50 dB max. 15 dBm - fN - 130 fN + 30 MHz MHz 50 40...45 τC ∆τC ∆ϕ Reflected attenuation compared to main signal Crosstalk attenuation compared to main signal Triple transit attenuation compared to main signal Input power level 31 - MHz MHz Group delay (mean value) in fN ± 21 MHz Group delay ripple (p-p) in fN ± 21 MHz Phase ripple (p-p) in fN ± 21 MHz max. arel fN ± 22,5 MHz .... fN ± 24 fN ± 24,5 MHz .... fN ± 30 MHz .... fN - 30 MHz .... fN + 140 dB 60 55 60 dB dB dB - Temperature coefficient of frequency : Tcf -72 ppm/K ∆fc(Hz) = Tcf (ppm/K) x (T - TA) x fCTA (MHz) Frequency deviation of fc over temperature: **) Operable temperature range : OTR - 40 °C ... + 85 °C Storage temperature range : STR - 40 °C ... + 85 °C *) fc(23°C) = 140,220 ±0,250 MHz. **) fCTA is reference frequency fc at ambient temperature (TA = 45°C ). Generated: W. Dunzow Checked/Approved: Dr. Bert Wall VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140K.doc version 1.1 VI TELEFILTER Filter specification 26.02.2002 TFS 140K 2/5 3. Construction and pin connection : (All dimensions in mm) pin grid 2,54 mm 13,0 Max. TFS 1 140K P22 Date-code 25,0 Max. Date-code: M N P ... 5,0 Max. 3,20 ø 0,50Max. 5 6 7 8 Pin 3 Pin 2 Pin 11 Pin 10 Pin 1, 8, 9, 16 Pin 6, 7, 14, 15 7,62 1 2 3 16 15 14 Year+week 2000 2001 2002 ... 12 11 10 9 Input Input RF Return Output Output RF Return Pakage Ground Ground 7X2,54=17,78 4. 50 Ω matching network ( please refer to the application note for further matching information ) : 1 2 3 6 7 8 50 Ω 50 Ω Scheme 1. 16 15 14 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] 11 10 9 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140K.doc version 1.1 VI TELEFILTER Filter specification 26.02.2002 TFS 140K 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140K.doc version 1.1 VI TELEFILTER Filter specification 26.02.2002 TFS 140K 4/5 6. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: Tfs140K.doc VI TELEFILTER version 1.1 Filter specification 26.02.2002 TFS 140K 5/5 7. History : Version Reason of changes Name Date 1.0 Generate development specification. Dunzow W. 20.02.2002 1.1 Generate filter specification. Dunzow W. 20.02.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.