High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE The following data sheets contain information obtained directly from the manufacturer’s installation instruction manuals. Within each application there are specific requirements that detail how the Power Electronic Equipment should be installed and the proper overcurrent protection that has been tested and approved by certified testing agencies. The part numbers shown in this guide were obtained from the latest available published information from the manufacturer. It is recommended that each installation be checked against the manufacturer’s installation guides to determine if any additional requirements are needed. Bussmann is not responsible for mis-application of our products. For the latest, most up-to-date product specifications listed in this guide please visit us at http://www.bussmann.com or by calling the Bussmann Information Fax (BIF) at 636-527-1450. This guide is intended to clearly represent product data and provide technical information that will help the end user with design/installation applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any information contained in this guide. Once a product has been selected, it should be checked and tested by the end user in all possible applications. P.O. Box 14460 St. Louis, MO 63178-4460 (636) 394-2877 3/11/200 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1302 AC Drive (575 Volts) Maximum Short Circuit Rating is 30kA AC Input Line Fuse Selection Values Model Voltage Number V 1302–C001–AA 575 1302–C001–AF 575 1302–C002–AA 575 1302–C002–AF 575 1302–C003–AA 575 1302–C003–AF 575 1302–C004–AA 575 1302–C005–AA 575 1302–C005–AF 575 1302–C007–AF 575 1302–C010–AA 575 1302–C010–AF 575 Fuse Block J60030-3CR or JP60030-3CR HP 1 1 2 2 3 3 5 5 7.5 7.5 10 10 Input Current A 2 2 3.4 3.4 5.2 5.2 7.5 7.5 10.9 10.9 14.5 14.5 Fuse Part Number LPJ-4SP LPJ-4SP LPJ-7SP LPJ-7SP LPJ-10SP LPJ-10SP LPJ-15SP LPJ-15SP LPJ-20SP LPJ-20SP LPJ-25SP LPJ-25SP Disconnect Switch CFD30J3 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1305 Adjustable Frequency AC Drive (Series C) 0.37 - 5kW (0.5 - 5 HP) Catalog Number 1305-AA02A 1305-AA03A 1305-AA04A 1305-AA08A 1305-AA12A 1305-BA01A 1305-BA02A 1305-BA03A 1305-BA04A 1305-BA06A 1305-BA09A KTK-R LPJ Voltage V 200-230 200-230 200-230 200-230 200-230 380-460 380-460 380-460 380-460 380-460 380-460 (0 to 30) (0 to 30) Three Phase Input HP kW 0.5 0.37 0.75 0.55 1 0.75 2 1.5 3 2.2 0.5 0.37 0.75 0.55 1 0.75 2 1.5 3 2.2 5 4 Single Phase Input HP kW 0.25 0.19 0.5 0.37 0.75 0.55 1 0.75 2 1.5 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR Bussmann Class CC KTK-R-6 KTK-R-6 KTK-R-10 KTK-R-15 KTK-R-25 KTK-R-6 KTK-R-10 KTK-R-15 KTK-R-20 Bussmann Class J LPJ-6SP LPJ-6SP LPJ-10SP LPJ-15SP LPJ-25SP LPJ-3SP LPJ-3SP LPJ-6SP LPJ-10SP LPJ-15SP LPJ-20SP Disconnect Switches CFD30CC3 CFD30J3 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1329 Intergrated Drive/Motor (Series B) 1,0 to 5.0 HP Maximum Short Circuit Rating is 10kA Catalog Number 1329I-BJ001 1329I-BK001 1329I-BK002 1329I-BL001 1329I-BL002 1329I-BM001 1329I-BM002 1329I-BM003 1329I-BM005 KTK-R LPJ Single Phase Three Phase Voltage Voltage 115 230 230 230 230 460 460 460 460 (0 to 30) (0 to 30) HP 1 1 2 1 2 1 2 3 5 Input Current 14 5.8 14 4.5 7.6 2.3 3.7 5.7 9 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR Bussmann Class CC KTK-R-20 KTK-R-9 KTK-R-20 KTK-R-7 KTK-R-12 KTK-R-3.5 KTK-R-6 KTK-R-9 KTK-R-15 Bussmann Class J LPJ-20SP LPJ-9SP LPJ-20SP LPJ-7SP LPJ-12SP LPJ-3.5SP LPJ-6SP LPJ-9SP LPJ-15SP Disconnect Switches CFD30CC3 CFD30J3 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1333 3/4 to 20HP (.55-15kW) Adjustable Frequency AC Drive Series D Catalog Number 1333-ZAA 1333-AAA 1333-YAA 1333-BAA 1333-CAA 1333-DAA 1333-EAA 1333-FAA 1333-GAA 1333-AAB 1333-YAB 1333-BAB 1333-CAB Amperage 0 to 30 35 to 60 65 to 100 110 to 200 HP kW 0.75 0.55 1 0.75 2 1.5 3 2.2 5 4 7.5 5.5 10 7.5 15 11 20 15 1 0.75 2 1.5 3 2.2 5 4 Single Phase Voltage 230 230 230 230 230 230 230 230 230 Three Phase Voltage 230 230 230 230 230 230 230 230 230 460 460 460 460 Single Phase Current 6.2 8.6 9.5 13 18.8 23.4 31.1 41.6 54.6 Three Phase Current 4.1 6.5 9 14 22 27 37 47 62 3.3 4.5 8 13 Bussmann Class RK5 FRS-R-15 FRS-R-15 FRS-R-15 FRS-R-30 FRS-R-40 FRS-R-70 FRS-R-80 FRS-R-100 FRS-R-125 FRS-R-15 FRS-R-15 FRS-R-15 FRS-R-20 Fuse Blocks R60030-3CR R60060-3CR R60100-3CR R60200-3CR 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1336 FORCE Adjustable Frequncy AC Drive 0.75 - 485 kW (1 - 650 HP) Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Drive Catalog Rating Number kW 1336T– _ _ F10 0.75 1336T– _ _ F30 2.2 1336T– _ _ F50 3.7 1336T– _ _ 001 0.75 1336T– _ _ 003 2.2 1336T– _ _ 007 5.5 1336T– _ _ 010 7.5 1336T– _ _ 015 11 1336T– _ _ 020 15 1336T– _ _ 025 18.5 1336T– _ _ 030 22 1336T– _ _ 040 30 1336T– _ _ 050 37 1336T– _ _ X060 45 1336T– _ _ 060 45 1336T– _ _ 075 56 1336T– _ _ 100 75 1336T– _ _ 125 93 1336T– _ _ X150 112 1336T– _ _ 150 112 1336T– _ _ 200 149 1336T– _ _ 250 187 1336T– _ _ X300 224 KTK-R LPJ JJS Amps 0 to 30 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 Fuse Ratings (fuses are user supplied) Use Bussmann LPJ, KTK-R or JJS Fuses HP 200–240V 380–480V 500–600V 1 10 6 – 3 25 15 – 5 40 20 – 1 10 6 6 3 15 10 10 7.5 40 20 15 10 50 30 20 15 70 35 25 20 100 45 35 25 100 60 40 30 125 70 50 40 150 80 60 50 200 100 80 60 – 100 – 60 250 125 90 75 – 150 110 100 – 200 150 125 – 250 175 150 – 250 – 150 – 300 225 200 – 400 350 250 – 450 400 300 – – 400 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR J60060-3CR J60100-3CR J60200-3CR J60400-3CR J60600-3CR T60030-3CR T60060-3CR T60100-3C T60200-1C (Single pole blocks) T60400-1C (Single pole blocks) T60600-1C (Single pole blocks) Disconnect Switches CFD30CC3 CFD30J3 CDF60J3 CFD100J3 FD200J3 FD400J3 FD600J3 CFD100J3/BDTA1 FD200J3/BDTA2 FD400J3/BDTA4 FD600J3/BDTA6 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE (cont.) Model 1336 FORCE Adjustable Frequncy AC Drive 0.75 - 485 kW (1 - 650 HP) Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Use Bussmann Semiconductor Fuses Drive Catalog Rating 380–480V Number kW HP 200–240V 500–600V FWP-450A 1336T– _ _ X250 187 250 – – FWP-450A 1336E– _ _ P250 187 250 – – FWP-450A 1336T– _ _ 300T 224 300 – FWP-400A FWP-500A 1336E– _ _ 300 224 300 – FWP-450A FWP-500A 1336T– _ _ 350 261 350 – FWP-450A FWP-600A 1336E– _ _ 350 261 350 – FWP-600A 1336T– _ _ 400 298 400 – FWP-500A FWP-600A 1336E– _ _ 400 298 400 – FWP-800A 1336T– _ _ 450 336 450 – FWP-600A FWP-700A 1336E– _ _ 450 336 450 – FWP-600A FWP-800A 1336T– _ _ 500 373 500 – FWP-800A FWP-900A 1336T– _ _ 600 448 600 – FWP-800A – 1336T– _ _ 650 485 650 – FWP-800A 1336T– _ _ 700C 522 700 – FWP-600A{1} FWP-700A{1} 1336T– _ _ 800C 597 800 – FWP-700A{1} FWP-700A{1} {1} Two Fuses in parallel are required. FWP Amps 450 - 600 700 Fuse Blocks 1BS104 BH-3145 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1336 IMPACT Adjustable Frequency AC Drive 0.37 - 597 kW (0.5 - 800 HP) Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Use Bussmann LPJ, KTK-R or JJS Fuses Drive Catalog Rating Number kW HP 200–240V 380–480V 500–600V 1336E-_ _ F05 0.37 0.5 6 3 1336E-_ _ F07 0.56 0.75 6 3 1336E-_ _ F10 0.75 1 10 6 3 1336E-_ _ F15 1.2 1.5 15 6 1336E-_ _ F20 1.5 2 15 10 6 1336E-_ _ F30 2.2 3 25 15 10 1336E-_ _ F50 3.7 5 40 20 0.1 1336E-_ _ F75 5.5 7.5 20 15 1336E-_ _ F100 7.5 10 30 20 1336E-_ _ 007 5.5 7.5 40 20 15 1336E-_ _ 010 7.5 10 50 30 20 1336E-_ _ 015 11 15 70 35 25 1336E-_ _ 020 15 20 100 45 35 1336E-_ _ 025 18.5 25 100 60 40 1336E-_ _ 030 22 30 125 70 50 1336E-_ _ X040 30 40 150 80 60 1336E-_ _ 040 30 40 150 80 60 1336E-_ _ 050 37 50 200 100 80 1336E-_ _ X060 45 60 100 1336E-_ _ 060 45 60 250 125 90 1336E-_ _ 075 56 75 300 150 110 1336E-_ _ 100 75 100 400 200 150 1336E-_ _ 125 93 125 450 250 175 1336E-_ _ X150 112 150 250 1336E-_ _ 150 112 150 300 225 1336E-_ _ 200 149 200 400 350 1336E-_ _ 250 187 250 450 400 1336E-_ _ X300 224 300 400 KTK-R LPJ JJS Amps 0 to 30 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR J60060-3CR J60100-3CR J60200-3CR J60400-3CR J60600-3CR T60030-3CR T60060-3CR T60100-3C T60200-1C (Single pole blocks) T60400-1C (Single pole blocks) T60600-1C (Single pole blocks) Disconnect Switches CFD30CC3 CFD30J3 CDF60J3 CFD100J3 FD200J3 FD400J3 FD600J3 CFD100J3/BDTA1 FD200J3/BDTA2 FD400J3/BDTA4 FD600J3/BDTA6 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE (cont.) Model 1336 IMPACT Adjustable Frequency AC Drive 0.37 - 597 kW (0.5 - 800 HP) Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Drive Catalog Rating Use Bussmann Semiconductor Fuses Number kW HP 200–240V 380–480V 500–600V 1336E-_ _ 300 224 300 FWP-500A FWP-400A 1336E-_ _ P300 224 300 FWP-500A 1336E-_ _ 350 224 300 FWP-600A FWP-450A 1336E-_ _ P350 261 350 FWP-600A 1336E-_ _ 400 298 400 FWP-600A FWP-500A 1336E-_ _ P400 298 400 FWP-600A 1336E-_ _ 450 336 450 FWP-800A FWP-600A 1336E-_ _ P450 336 450 FWP-700A 1336E-_ _ 500 373 500 FWP-800A FWP-800A 1336E-_ _ 600 448 600 FWP-900A FWP-800A 1336E-_ _ 650 485 650 FWP-800A 1336E-_ _ 700C 522 700 FWP-600A{1} FWP-700A{1} 1336E-_ _ 800C 597 800 FWP-700A{1} FWP-700A{1} {1} Two Fuses in parallel are required. FWP Amps 450 - 600 700 Fuse Blocks 1BS104 BH-3145 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1336 PLUS Adjustable Frequency AC Drive 0.37 - 448 kW (0.5 - 600 HP) Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Use Bussmann LPJ, KTK-R or JJS Fuses Drive Catalog Rating Number kW HP 200–240V 380–480V 500–600V 1336S-_ _ F05 0.37 0.5 6 3 1336S-_ _ F07 0.56 0.75 6 3 1336S-_ _ F10 0.75 1 10 6 6 1336S-_ _ F15 1.2 1.5 15 6 1336S-_ _ F20 1.5 2 15 10 10 1336S-_ _ F30 2.2 3 25 15 15 1336S-_ _ F50 3.7 5 40 20 20 1336S-_ _ F75 5.5 7.5 20 1336S-_ _ F100 7.5 10 30 1336S-_ _ 007 5.5 7.5 40 20 15 1336S-_ _ 010 7.5 10 50 30 20 1336S-_ _ 015 11 15 70 35 25 1336S-_ _ 020 15 20 100 45 35 1336S-_ _ 025 18.5 25 100 60 40 1336S-_ _ 030 22 30 125 70 50 1336S-_ _ 040 30 40 150 80 60 1336S-_ _ 050 37 50 200 100 80 1336S-_ _ X060 45 60 100 1336S-_ _ 060 45 60 250 125 90 1336S-_ _ 075 56 75 300 150 110 1336S-_ _ 100 75 100 400 200 150 1336S-_ _ 125 93 125 450 250 175 1336S-_ _ X150 112 150 250 1336S-_ _ 150 112 150 300 225 1336S-_ _ 200 149 200 400 350 1336S-_ _ 250 187 250 450 400 1336S-_ _ X300 224 300 400 KTK-R LPJ JJS Amps 0 to 30 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR J60060-3CR J60100-3CR J60200-3CR J60400-3CR J60600-3CR T60030-3CR T60060-3CR T60100-3C T60200-1C (Single pole blocks) T60400-1C (Single pole blocks) T60600-1C (Single pole blocks) Disconnect Switches CFD30CC3 CFD30J3 CDF60J3 CFD100J3 FD200J3 FD400J3 FD600J3 CFD100J3/BDTA1 FD200J3/BDTA2 FD400J3/BDTA4 FD600J3/BDTA6 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE (cont.) Model 1336 PLUS Adjustable Frequency AC Drive 0.37 - 448 kW (0.5 - 600 HP) Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Drive Catalog Rating Use Bussmann Semiconductor Fuses Number kW HP 200–240V 380–480V 500–600V 1336S-_ _ P250 187 250 FWP-450A 1336S-_ _ X250 187 250 FWP-450A 1336S-_ _ 300 224 300 FWP-450A FWP-400A 1336S-_ _ P300 224 300 FWP-500A 1336S-_ _ 350 261 350 FWP-500A FWP-450A 1336S-_ _ P350 261 350 FWP-600A 1336S-_ _ 400 298 400 FWP-600A FWP-500A 1336S-_ _ P400 298 400 FWP-600A 1336S-_ _ 450 336 450 FWP-800A FWP-600A 1336S-_ _ P450 336 450 FWP-700A 1336S-_ _ 500 373 500 FWP-800A FWP-800A 1336S-_ _ 600 448 600 FWP-900A FWP-800A FWP Amps 450 - 600 700 Fuse Blocks 1BS104 BH-3145 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE M odel 1336 PLUS II Adjustable Frequency AC Drive 0.37 - 448 kW (0.5 - 600 HP) M aximum Short Circuit Rating is 200kA M aximum Recom mended AC Input Line Fuse Ratings (fuses are user supplied) Use Bussm ann LPJ, KTK-R or JJS Fuses Drive Catalog Rating Num ber kW HP 200–240V 380–480V 500–600V 1336F- _ _ F05 0.37 0.5 4 3 1336F- _ _ F05 Series A 0.37 0.5 6 3 1336F- _ _ F07 0.56 0.75 4 3 1336F- _ _ F07 Series A 0.56 0.75 6 3 1336F- _ _ F10 0.75 1 6 3 3 1336F- _ _ F10 Series A 0.75 1 10 6 6 1336F- _ _ F15 1.2 1.5 8 4 1336F- _ _ F15 Series A 1.2 1.5 15 6 1336F- _ _ F20 1.5 2 10 5 6 1336F- _ _ F20 Series A 1.5 2 15 10 10 1336F- _ _ F30 2.2 3 15 8 10 1336F- _ _ F30 Series A 2.2 3 25 15 15 1336F- _ _ F50 3.7 5 25 12 15 1336F- _ _ F50 Series A 3.7 5 40 20 20 1336F- _ _ F75 5.5 7.5 30 20 15 1336F- _ _ F100 7.5 10 30 20 1336F- _ _ F150 11 15 35 25 1336F- _ _ F200 15 20 35 30 1336F- _ _ 007 5.5 7.5 40 20 15 1336F- _ _ 010 7.5 10 50 30 20 1336F- _ _ 015 11 15 70 35 25 1336F- _ _ 020 15 20 100 45 35 1336F- _ _ 025 18.5 25 100 60 40 1336F- _ _ 030 22 30 125 70 50 1336F- _ _ 040/X040 30 40 150 80 60 1336F- _ _ 050 37 50 200 100 80 1336F- _ _ X060 45 60 100 1336F- _ _ 060 45 60 250 125 90 1336F- _ _ 075 56 75 300 150 110 1336F- _ _ 100 75 100 400 200 150 1336F- _ _ 125 93 125 450 250 175 1336F- _ _ X150 112 150 250 1336F- _ _ 150 112 150 300 225 1336F- _ _ 200 149 200 400 350 1336F- _ _ 250 187 250 450 400 1336F- _ _ X300 224 300 400 KTK-R LPJ JJS Am ps Fuse Blocks Disconnect Switches 0 to 30 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR J60060-3CR J60100-3CR J60200-3CR J60400-3CR J60600-3CR T60030-3CR T60060-3CR T60100-3C T60200-1C (Single pole blocks) T60400-1C (Single pole blocks) T60600-1C (Single pole blocks) CFD30CC3 CFD30J3 CDF60J3 CFD100J3 FD200J3 FD400J3 FD600J3 CFD100J3/BDTA1 FD200J3/BDTA2 FD400J3/BDTA4 FD600J3/BDTA6 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE (cont.) Model 1336 PLUS II Adjustable Frequency AC Drive 0.37 - 448 kW (0.5 - 600 HP) Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Drive Catalog Rating Use Bussmann Semiconductor Fuses Number kW HP 200–240V 380–480V 500–600V 1336F- _ _ BP/BPR250 187 250 FWP-450A 1336F- _ _ X250 187 250 FWP-450A 1336F- _ _ 300 224 300 FWP-450A FWP-400A 1336F- _ _ BP/BPR300 224 300 FWP-500A 1336F- _ _ 350 261 350 FWP-500A FWP-450A 1336F- _ _ BP/BPR350 261 350 FWP-600A 1336F- _ _ 400 298 400 FWP-600A FWP-500A 1336F- _ _ BP/BPR400 298 400 FWP-600A 1336F- _ _ 450 336 450 FWP-800A FWP-600A 1336F- _ _ BP/BPR450 336 450 FWP-700A 1336F- _ _ 500 373 500 FWP-800A FWP-800A 1336F- _ _ 600 448 600 FWP-900A FWP-800A FWP Amps 450 - 600 700 Fuse Blocks 1BS104 BH-3145 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1336 SPIDER Adjustable Frequency Drive for the Fibers Industry 9.9A - 60A Maximum Short Circuit Rating is 200kA Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Use Bussmann LPJ, KTK-R or JJS Fuses Drive Catalog Rating Input kW Current 200–240V 380–480V Number 1336Z- _ _ A022 1.8 7.6 30 1336Z- _ _ A036 3 12.5 30 1336Z- _ _ A060 5 24.6 50 1336Z- _ _ B010 1.6 8.7 20 1336Z- _ _ B017 2.7 11.4 20 1336Z- _ _ B033 5.5 19.8 40 KTK-R LPJ JJS Amps 0 to 30 0 to 30 35 to 60 0 to 30 35 to 60 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR J60060-3CR T60030-3CR T60060-3CR Disconnect Switches CFD30CC3 CFD30J3 CDF60J3 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE 1336/1336VT/1336 PLUS/1336 PLUS II/FORCE/IMPACT Series A Brake Chopper Dynamic Brake Fuse All brake modules are internally fused to protect brake components. Dynamic Brake Fuse Rating Recommended Fuse 1336-WA018 F1 & F2 30A, 600V FWC-30A10F 1336-WB009 F1 & F2 15A, 600V FWC-15A10F 1336-WC009 F1 & F2 15A, 600V FWC-15A10F 1336-WA070 F1 & F2 125A, 700V FWP-125A 1336-WB035 F1 & F2 60A, 700V FWP-60A 1336-WC035 F1 & F2 60A, 700V FWP-60A 1336-WA115 F1 & F2 200A, 700V FWP-200A 1336-WB110 F1 & F2 200A, 700V FWP-200A 1336-WC085 F1 & F2 200A, 700V FWP-200A 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1336 Adjustable Frequency AC Drive Maximum Recommended AC Input Line Fuse Ratings (fuses are user supplied) Input Input Recommended Bussmann Catalog Number Current Voltage 1336-B003 5.7 460 KTK-R-10 JJS-10 1336-B005 9.2 460 KTK-R-15 JJS-15 1336-B007 13.3 460 KTK-R-20 JJS-20 1336-B010 17 460 KTK-R-25 JJS-25 1336-B015 25 460 JJS-35 1336-B020 34 460 JJS-45 1336-B025 42 460 JJS-60 1336-B030 49 460 JJS-70 1336-B040 61 460 JJS-80 1336-B050 76 460 JJS-100 1336-B075 122 460 JJS-150 1336-B100 153 460 JJS-200 1336-B125 184 460 JJS-250 1336-B150 222 460 JJS-300 1336-B200 296 460 JJS-400 1336-C003 3.2 575 KTK-R-6 JJS-6 1336-C005 4.1 575 KTK-R-6 JJS-6 1336-C007 7.7 575 KTK-R-10 JJS-10 1336-C010 10.2 575 KTK-R-15 JJS-15 1336-C015 15 575 JJS-20 1336-C020 19 575 JJS-25 1336-C025 24 575 JJS-30 1336-C030 29 575 JJS-35 1336-C040 39 575 JJS-45 1336-C050 48 575 JJS-60 1336-C075 73 575 JJS-90 1336-C100 97 575 JJS-125 1336-C125 121 575 JJS-150 1336-C150 146 575 JJS-175 1336-C200 193 575 JJS-250 KTK-R LPJ JJS Amps 0 to 30 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR J60060-3CR J60100-3CR J60200-3CR J60400-3CR T60030-3CR T60060-3CR T60100-3C T60200-1C (Single pole blocks) T60400-1C (Single pole blocks) Fuse JKS-35 JKS-45 JKS-60 JKS-70 JKS-80 JKS-100 JKS-150 JKS-200 JKS-250 JKS-300 JKS-400 JKS-20 JKS-25 JKS-30 JKS-35 JKS-45 JKS-60 JKS-90 JKS-125 JKS-150 JKS-175 JKS-250 Disconnect Switches CFD30CC3 CFD30J3 CDF60J3 CFD100J3 FD200J3 FD400J3 CFD100J3/BDTA1 FD200J3/BDTA2 FD400J3/BDTA4 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Heavy Duty Dynamic Braking for use with 1336/1336VT/1336 PLUS/1336 FORCE Drives All brake modules are internally fused to protect brake components. Dynamic Brake Fuse Rating Recommended Fuse 1336-MOD-KA005 F1 10A, 500V FWH-10A14F 1336-MOD-KB005 F1 5A, 600V FWC-5A10F 1336-MOD-KC005 F1 5A, 700V FWP-5A14F 1336-MOD-KA010 F1 20A, 500V FWH-20A14F 1336-MOD-KB010 F1 10A, 600V FWC-10A10F 1336-MOD-KC010 F1 10A, 700V FWP-10A14F 1336-MOD-KA050 F1 & F2 50A, 500V FWH-50A 1336-MOD-KB050 F1 & F2 35A, 700V FWP-35A 1336-MOD-KC050 F1 & F2 35A, 700V FWP-35A 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1336VT Adjustable Frequency AC Drive Catalog Number 1336VT-B003 1336VT-B005 1336VT-B007 1336VT-B010 1336VT-B015 1336VT-B020 1336VT-B025 1336VT-B030 1336VT-B040 1336VT-B050 1336VT-B060 1336VT-B075 1336VT-B100 1336VT-B125 1336VT-B150 1336VT-B200 1336VT-B250 KTK-R LPJ JJS Input Current 5.6 7.5 11.4 14.6 22 28 35 44 54 67 78 97 124 154 178 235 296 Amps 0 to 30 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 0 to 30 35 to 60 65 to 100 110 to 200 225 to 400 450 to 600 Input Voltage 460 460 460 460 460 460 460 460 460 460 460 460 460 460 460 460 460 Recommended Bussmann Fuse KTK-R-10 KTK-R-15 KTK-R-20 KTK-R-25 Fuse Blocks BC6033B or OPM-NG-SC3 J60030-3CR or JP60030-3CR J60060-3CR J60100-3CR J60200-3CR J60400-3CR J60600-3CR T60030-3CR T60060-3CR T60100-3C T60200-1C (Single pole blocks) T60400-1C (Single pole blocks) T60600-1C (Single pole blocks) JJS-35 JJS-45 JJS-60 JJS-70 JJS-80 JJS-100 JJS-110 JJS-150 JJS-200 JJS-250 JJS-300 JJS-400 JJS-500 JKS-30 JKS-45 JKS-60 JKS-60 JKS-80 JKS-100 JKS-110 JKS-150 JKS-200 JKS-250 JKS-300 JKS-400 JKS-500 Disconnect Switches CFD30CC3 CFD30J3 CDF60J3 CFD100J3 FD200J3 FD400J3 FD600J3 CFD100J3/BDTA1 FD200J3/BDTA2 FD400J3/BDTA4 FD600J3/BDTA6 3/11/2002 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1391-DES Digital AC Servo Drive Recommended fuse for transformer primary protection XFMR Catalog Number KVA Rating 208 240 1391-T015 1.5 FRS-R-8 FRS-R-7 1391-T035 3.5 FRS-R-17-1/2 FRS-R-15 1391-T050 5 FRS-R-20 FRS-R-20 1391-T100 10 FRS-R-40 FRS-R-35 1391-T125 12.5 FRS-R-50 FRS-R-45 1391-T150 15 FRS-R-60 FRS-R-50 Voltage 380 415 FRS-R-4-1/2 FRS-R-4 FRS-R-9 FRS-R-8 FRS-R-12 FRS-R-12 FRS-R-25 FRS-R-20 FRS-R-30 FRS-R-25 FRS-R-35 FRS-R-30 480 FRS-R-3-1/2 FRS-R-7 FRS-R-10 FRS-R-17-1/2 FRS-R-25 FRS-R-30 Recommended fusing for shunt regulator. Drive Rating Fuse Location Bussmann 15 Amps Top Panel KLM-10 22.5 Amps Top Panel FNM-6-1/4 22.5 Amps External KTK-15 45 Amps External KLM-20 3/11/2002 575 FRS-R-3 FRS-R-6 FRS-R-8 FRS-R-15 FRS-R-20 FRS-R-25 High Speed Fuses Bussmann Fuses in Allen-Bradley Drives TECHNICAL LITERATURE Model 1394 Digital AC Multi-Axis Motion Control System Maximum Short Circuit Rating of 100kA Line Input Fusing Catalog Number 1394-SJT05 Systems 1394C-SJT05 Systems 1394-SJT10 Systems 1394C-SJT10 Systems 1394x-SJT22 Systems Shunt Module Catalog Number 1394-SR9A 1394-SR9AF 1394-SR10A 1394-SR36A 1394-SR36AF Series Series A and B Series C Series A and B Series C Shunt has UL FWP-50A14F FWP-50A14F FWP-40A14F FWP-50A14F FWP-50A14F 24 Volt Logic Input Power 24V logic input voltage 19-28V AC 19-28V AC 18.75-31.25 DC 18.75-31.25 DC Axis 1 2 3 4 Recommended Bussmann Fuses FRS-R-20 KTK-R-20 LPJ-20SP FRS-R-30 KTK-R-30 LPJ-30SP FRS-R-35 LPS-RK-40SP LPJ-45SP Shunt has no UL 170N2013 FWP-50A22F 170N2013 FWP-50A22F 170N2013 170N2013 Current 3.5 4.4 5.2 6 FWP-50A22F FWP-50A22F Recommended Fuse MDA-15 MDA-15 MDA-15 MDA-15 3/11/2002