POWER RELAY 1 POLE—10 A (CADMIUM FREE CONTACTS TYPE) FTR-H2 SERIES RoHS compliant RoHS compliant n Features HIGH DENSITY MOUNTING Saves space by 26% compared to FTR-H1 type. l HIGH ISOLATION Insulation Distance: Minimum 6mm between coil and contact Dielectric Strength: 4KV Surge Strength: 10KV l TV-5 rating l HEAT RESISTANCE, FLAMMABILITY Class B (130° C) insulation, flammability 94V-0 l CADMIUM FREE CONTACT FOR ECO-PROGRAM l SAFETY STANDARDS UL, CSA, VDE approved, SEMKO (pending) UL/CSA TV-5 rating approved l RoHS compliant since date code: 0437L2 Please see page 8 for more information l nORDERING INFORMATION [Example] FTR-H2 A K 012 T (a) (b)(c) (d) (e) (a) Series name FTR-H2: FTR-H2 series (10A) (b) Contact arrangement A: 1 Form A (SPST-NO) (c) Coil type K: Standard (530mW) L: High sensitivity (250mW) A: Sealed (530mW) (d) Coil nominal voltage 005 : 5DC 012 : 12DC 048 : 48DC 006 : 6DC 018 : 18DC 009 : 9DC 024 : 24DC (e) Contact material T: Silver-tin oxide (TV-5) FTR-H2 Series nPART NUMBERS Standard: 530 mW, High sensitive (250 mW), Sealed (530 mW) Ordering Part Number Series Contact Coil Power Coil Voltage FTR-H2AK005T 5 FTR-H2AK006T 6 FTR-H2AK009T K: 530mW (standard) FTR-H2AK012T FTR-H2AK018T 9 12 18 FTR-H2AK024T 24 FTR-H2AK048T 48 FTR-H2AL005T 5 FTR-H2AL006T FTR-H2AL009T FTR-H2 1 form A FTR-H2AL012T L: 250mW (High sensitivity) 6 12 24 FTR-H2AA005T 5 FTR-H2AA006T 6 A: 530mW (sealed) FTR-H2AA012T FTR-H2AA018T Silver tin oxide (TV-5 rated) 9 FTR-H2AL024T FTR-H2AA009T Contact Material 9 12 18 FTR-H2AA024T 24 FTR-H2AA048T 48 n COIL DATA CHART Standard Type (530mW) Coil Voltage Nominal Voltage (VDC) Max. Coil Voltage*1 Coil Resistance Must Operate ( ±10%) Voltage*2 Must Release Voltage*2 005 5 8.5 VDC 47 Ω 3.5 VDC 0.25 VDC 006 6 10.2 VDC 68 Ω 4.2 VDC 0.3 VDC 009 9 15.3 VDC 155 Ω 6.3 VDC 0.45 VDC 012 12 20.4 VDC 270 Ω 8.4 VDC 0.6 VDC 018 18 30.6 VDC 610 Ω 12.6 VDC 0.9 VDC 024 24 40.8 VDC 1,110Ω 16.8 VDC 1.2 VDC 048 48 81.6 VDC 4,400 Ω 33.6 VDC 2.4 VDC FTR-H2 Series Sensitive Type (250mW) Coil Voltage Nominal Voltage (VDC) Max. Coil Voltage*1 Coil Resistance Must Operate Must Release ( ±10%) Voltage*2 Voltage*2 005 5 12.5 VDC 100 Ω 4.0 VDC 0.25 VDC 006 6 15.0 VDC 145 Ω 4.8 VDC 0.30 VDC 009 9 22.5 VDC 325 Ω 7.2 VDC 0.45 VDC 012 12 30.0 VDC 575 Ω 9.6 VDC 0.60 VDC 024 24 60.0 VDC 2,310 Ω 19.2 VDC 1.20 VDC Note: All values in the table are measured at 20°C. *1: No contact current at 20°C *2: Specified values are subject to pulse wave voltage nSPECIFICATIONS Item Contact Coil Sealed H2 AK ( ) T H2 AL ( ) T H2 AA ( ) T 1 form A (SPST-NO) Material Silver tin oxide Resistance (initial) Maximum 100 mΩ (at 6VDC, 1A) Rating (resistive) 250 VAC / 30 VDC / 10A Maximum Carrying Current 10A Maximum Switching Rating 2500VA / 300W Maximum Switching Voltage 400VAC / 300VDC Minimum Switching Load* 100 mA, 5 VDC Nominal Power (20°C) 530 mW 250 mW 530 mW Operate Power (20°C) 260 mW 160 mW 260 mW Operating Temperature -40ºC to +70ºC (no frost) Maximum 15 ms Release Time (at nominal voltage) Maximum 5 ms Mechanical 2 x 106 operations minimum Electrical Other Sensitive Arrangement Time Value Operate Time (at nominal voltage) Life Standard AC Contact rating 100 x 103 operations min. 50 x 103 operations min. DC Contact Rating 100 x 103 operations minimum 5 x 103 operations minimum Lamp load (TV-5) 25 x 103 operations minimum Vibration Resistance Misoperation 10 to 55 Hz, at double amplitude of 1.5 mm Endurance 10 to 55Hz, at double amplitude of 1.5 mm Shock Resistance Misoperation Weight Endurance 200m/s2 (11±1ms) 1,000m/s2 (11±1ms) Approximately 12g * Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels. FTR-H2 Series n INSULATION Item FTR-H2 Note Resistance (initial) Minimum 1,000 MΩ 1 min. at 500 VDC Dielectric Strength open contacts 1,000 VAC (50/60 Hz) 1 min. coil and contacts 4,000 VAC (50/60 Hz) 1 min. Surge Voltage (coil and contact) 10,000 V Clearance/Creepage 6 mm / 6 mm Insulation (DIN EN61810-1 VDE0435) Voltage Pollution Isolation material group 250 V 2 III a Isolation category / Reference voltage (VDE 0110b) 1.2 x 50µs standard wave B / 250 V n SAFETY STANDARDS Type Compliance Contact rating UL UL 508 Flammability: UL 94-V0 (plastics) 5A, 250VAC (resistive) 15A, 125VAC (resistive) 1/6 HP, 125VAC 1/2 HP, 250VAC TV-5, 120 VAC Pilot duty: C300 E63614 CSA C22.2 No. 14 LR 40304 VDE 0435, 0860 10A, 250 VAC (cosØ=1) 3A, 250 VAC cosØ=0.4) 10A, 30 VDC (0ms) SEMKO EN 61058-1: 1992 AND A1 EN 61095:1993 and A1+A11 250 VAC, 10 (3) or 5/80 40T70 Complies with CQC, NEMKO, DEMKO, FIMKO, FTR-H2 Series n CHARACTERISTIC DATA Temperaturerise(deg.) FTR-H2 80 60 0A 40 0A 20 0 0 0.2 0.4 0.6 0.8 Operatingrange 2.2 2.0 FTR-H2 .8 0A .6 .4 0A .2 Operatevoltage ofhotcoil .0 Operatevoltage ofcoolcoil 0.6 0 .2 20 40 50 60 FTR-H2 20 0 ACresistive 5 2 0.5 0.8 DCresistive 0.2 80 00 Ambienttemperature(°C) Coilpower(W) Servicelife(x04operations) Maximumswitchingpower 00 Contactcurrent(A) Nominalvoltagemult.factor Coiltemperaturerise 00 0 20 50 00 200 500 000 ContactVoltage(V) Lifecurve 00 FTR-H2 50 AC250V/DC30V AC250V Cosφ=0.7 20 DC30V τ=7ms 0 5 AC250V Cosφ=0.4 DC30V τ=15mS 2 0 2 4 6 8 0 2 4 Contactcurrentload(A) n REFERENCE DATA Distributionofoperate &releasevoltage 00 Distributionofcontactresistance 00 FTR-H2AA02T N=00 90 80 release 70 FTR-H2AK02T N=00 80 Distribution(%) Distribution(%) operate 60 50 40 30 make 60 40 20 20 0 0 0 0 0 20 30 40 50 60 70 80 Nominalvoltagemult.factor(%) 0 2 4 6 8 0 2 4 Contact resistance (mΩ) FTR-H2 Series nDIMENSIONS 11.0+0.3(.433+.012) 24.0 +0.3(.945+.012) l PC board mounting hole layout (BOTTOM VIEW) l Schematics (BOTTOM VIEW) 2 2-Ø 0.9(.035) 4 1.8(.071) 0.35(.014) 16.5 (.650 0.4(.016) 3.5(.138) 3 Orientation Mark 3.3 (.138) f0.5(.020) 2-Ø1.3(.051) 7.5(.295) 0.5(.020) 25.0 +0.3(.984+.012) 1 1.75(.069) l Dimensions De-energized condition 1.75(.069) 1.0(.039) 7.5(.295) 1.8(.071) 16.5(.650) 3.5(.138) Unit: mm (in.) FTR-H2 Series RoHS Compliance and Lead Free Relay Information 1. General Information Relays produced after the specific date code that is indicated on each data sheet are lead-free now. Most of our signal and power relays are lead-free. Please refer to Lead-Free Status Info. (http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf) l Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu. l All signal and most power relays also comply with RoHS. Please refer to individual data sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE). l It has been verified that using lead-free relays in leaded assembly process will not cause any problems (compatible). l “LF” is marked on each outer and inner carton. (No marking on individual relays). l To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office. l We will ship leaded relays as long as the leaded relay inventory exists. Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC) l 2. Recommended Lead Free Solder Profile l Recommended solder paste Sn-3.0Ag-0.5Cu. Reflow Solder condition Flow Solder condition: Pre-heating: Soldering: maximum 120˚C dip within 5 sec. at 260˚C soler bath Solder by Soldering Iron: Soldering Iron Temperature: maximum 360˚C Duration: maximum 3 sec. We highly recommend that you confirm your actual solder conditions 3. Moisture Sensitivity l Moisture Sensitivity Level standard is not applicable to electromechanical realys. 4. Tin Whisker l Dipped SnAgCu solder is known as low risk tin whisker. No considerable length whisker was found by our in house test. FTR-H2 Series Fujitsu Components International Headquarter Offices Japan Fujitsu Component Limited Gotanda-Chuo Building 3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141, Japan Tel: (81-3) 5449-7010 Fax: (81-3) 5449-2626 Email: [email protected] Web: www.fcl.fujitsu.com Europe Fujitsu Components Europe B.V. Diamantlaan 25 2132 WV Hoofddorp Netherlands Tel: (31-23) 5560910 Fax: (31-23) 5560950 Email: [email protected] Web: emea.fujitsu.com/components/ North and South America Fujitsu Components America, Inc. 250 E. Caribbean Drive Sunnyvale, CA 94089 U.S.A. Tel: (1-408) 745-4900 Fax: (1-408) 745-4970 Email: [email protected] Web: http://www.fujitsu.com/us/services/edevices/components/ Asia Pacific Fujitsu Components Asia Ltd. 102E Pasir Panjang Road #01-01 Citilink Warehouse Complex Singapore 118529 Tel: (65) 6375-8560 Fax: (65) 6273-3021 Email: [email protected] Web: http://www.fujitsu.com/sg/services/micro/components/ ©2008 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective owners. Fujitsu Components America or its affiliates do not warrant that the content of datasheet is error free. In a continuing effort to improve our products Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets without prior notice. Rev. January 9, 2008.