FUJITSU FTR

POWER RELAY
1 POLE—10 A (CADMIUM FREE CONTACTS TYPE)
FTR-H2 SERIES
RoHS
compliant
RoHS
compliant
n
Features
HIGH DENSITY MOUNTING
Saves space by 26% compared to FTR-H1 type.
l HIGH ISOLATION
Insulation Distance: Minimum 6mm between coil and
contact
Dielectric Strength: 4KV
Surge Strength: 10KV
l TV-5 rating
l HEAT RESISTANCE, FLAMMABILITY
Class B (130° C) insulation, flammability 94V-0
l CADMIUM FREE CONTACT FOR ECO-PROGRAM
l SAFETY STANDARDS
UL, CSA, VDE approved, SEMKO (pending)
UL/CSA TV-5 rating approved
l
RoHS compliant since date code: 0437L2
Please see page 8 for more information
l
nORDERING INFORMATION
[Example]
FTR-H2 A K 012 T
(a) (b)(c) (d) (e) (a)
Series name
FTR-H2: FTR-H2 series (10A)
(b)
Contact arrangement
A: 1 Form A (SPST-NO)
(c)
Coil type
K: Standard (530mW)
L: High sensitivity (250mW)
A: Sealed (530mW)
(d)
Coil nominal voltage
005 : 5DC 012 : 12DC 048 : 48DC
006 : 6DC 018 : 18DC
009 : 9DC
024 : 24DC
(e)
Contact material
T: Silver-tin oxide (TV-5)
FTR-H2 Series
nPART NUMBERS
Standard: 530 mW, High sensitive (250 mW), Sealed (530 mW) Ordering Part Number
Series
Contact
Coil Power
Coil Voltage
FTR-H2AK005T
5
FTR-H2AK006T
6
FTR-H2AK009T
K: 530mW
(standard)
FTR-H2AK012T
FTR-H2AK018T
9
12
18
FTR-H2AK024T
24
FTR-H2AK048T
48
FTR-H2AL005T
5
FTR-H2AL006T
FTR-H2AL009T
FTR-H2 1 form A
FTR-H2AL012T
L: 250mW
(High
sensitivity)
6
12
24
FTR-H2AA005T
5
FTR-H2AA006T
6
A: 530mW
(sealed)
FTR-H2AA012T
FTR-H2AA018T
Silver tin oxide
(TV-5 rated)
9
FTR-H2AL024T
FTR-H2AA009T
Contact Material
9
12
18
FTR-H2AA024T
24
FTR-H2AA048T
48
n COIL DATA CHART
Standard Type (530mW)
Coil Voltage
Nominal
Voltage (VDC)
Max. Coil
Voltage*1
Coil Resistance Must Operate
( ±10%)
Voltage*2
Must Release
Voltage*2
005
5
8.5 VDC
47 Ω
3.5 VDC
0.25 VDC
006
6
10.2 VDC
68 Ω
4.2 VDC
0.3 VDC
009
9
15.3 VDC
155 Ω
6.3 VDC
0.45 VDC
012
12
20.4 VDC
270 Ω
8.4 VDC
0.6 VDC
018
18
30.6 VDC
610 Ω
12.6 VDC
0.9 VDC
024
24
40.8 VDC
1,110Ω
16.8 VDC
1.2 VDC
048
48
81.6 VDC
4,400 Ω
33.6 VDC
2.4 VDC
FTR-H2 Series
Sensitive Type (250mW)
Coil Voltage
Nominal
Voltage (VDC)
Max. Coil
Voltage*1
Coil Resistance Must Operate Must Release
( ±10%)
Voltage*2
Voltage*2
005
5
12.5 VDC
100 Ω
4.0 VDC
0.25 VDC
006
6
15.0 VDC
145 Ω
4.8 VDC
0.30 VDC
009
9
22.5 VDC
325 Ω
7.2 VDC
0.45 VDC
012
12
30.0 VDC
575 Ω
9.6 VDC
0.60 VDC
024
24
60.0 VDC
2,310 Ω
19.2 VDC
1.20 VDC
Note: All values in the table are measured at 20°C.
*1: No contact current at 20°C
*2: Specified values are subject to pulse wave voltage
nSPECIFICATIONS
Item
Contact
Coil
Sealed
H2 AK ( ) T
H2 AL ( ) T
H2 AA ( ) T
1 form A (SPST-NO)
Material
Silver tin oxide
Resistance (initial)
Maximum 100 mΩ (at 6VDC, 1A)
Rating (resistive)
250 VAC / 30 VDC / 10A
Maximum Carrying Current
10A
Maximum Switching Rating
2500VA / 300W
Maximum Switching Voltage
400VAC / 300VDC
Minimum Switching Load*
100 mA, 5 VDC
Nominal Power (20°C)
530 mW
250 mW
530 mW
Operate Power (20°C)
260 mW
160 mW
260 mW
Operating Temperature
-40ºC to +70ºC (no frost)
Maximum 15 ms
Release Time (at nominal voltage)
Maximum 5 ms
Mechanical
2 x 106 operations minimum
Electrical
Other
Sensitive
Arrangement
Time Value Operate Time (at nominal voltage)
Life
Standard
AC Contact rating
100 x 103 operations min.
50 x 103 operations min.
DC Contact Rating
100 x 103 operations minimum
5 x 103 operations minimum
Lamp load (TV-5)
25 x 103 operations minimum
Vibration
Resistance
Misoperation
10 to 55 Hz, at double amplitude of 1.5 mm
Endurance
10 to 55Hz, at double amplitude of 1.5 mm
Shock
Resistance
Misoperation
Weight
Endurance
200m/s2 (11±1ms)
1,000m/s2 (11±1ms)
Approximately 12g
* Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual
load before production since reference values may vary according to switching frequencies, environmental conditions and
expected reliability levels.
FTR-H2 Series
n
INSULATION
Item
FTR-H2
Note
Resistance (initial)
Minimum 1,000 MΩ 1 min.
at 500 VDC
Dielectric
Strength
open contacts
1,000 VAC (50/60 Hz) 1 min.
coil and contacts
4,000 VAC (50/60 Hz) 1 min.
Surge Voltage (coil and contact)
10,000 V
Clearance/Creepage
6 mm / 6 mm
Insulation (DIN EN61810-1 VDE0435)
Voltage
Pollution
Isolation material group
250 V
2
III a
Isolation category / Reference voltage
(VDE 0110b)
1.2 x 50µs standard wave
B / 250 V
n SAFETY STANDARDS
Type
Compliance
Contact rating
UL
UL 508
Flammability: UL 94-V0 (plastics)
5A, 250VAC (resistive)
15A, 125VAC (resistive)
1/6 HP, 125VAC
1/2 HP, 250VAC
TV-5, 120 VAC
Pilot duty: C300
E63614
CSA
C22.2 No. 14
LR 40304
VDE
0435, 0860
10A, 250 VAC (cosØ=1)
3A, 250 VAC cosØ=0.4)
10A, 30 VDC (0ms)
SEMKO
EN 61058-1: 1992 AND A1
EN 61095:1993 and A1+A11
250 VAC, 10 (3) or 5/80
40T70
Complies with CQC, NEMKO, DEMKO, FIMKO,
FTR-H2 Series
n CHARACTERISTIC DATA
Temperaturerise(deg.)
FTR-H2
80
60
0A
40
0A
20
0
0
0.2
0.4
0.6
0.8
Operatingrange
2.2
2.0
FTR-H2
.8
0A
.6
.4
0A
.2
Operatevoltage
ofhotcoil
.0
Operatevoltage
ofcoolcoil
0.6
0
.2
20
40
50
60
FTR-H2
20
0
ACresistive
5
2
0.5
0.8
DCresistive
0.2
80
00
Ambienttemperature(°C)
Coilpower(W)
Servicelife(x04operations)
Maximumswitchingpower
00
Contactcurrent(A)
Nominalvoltagemult.factor
Coiltemperaturerise
00
0
20
50
00
200
500 000
ContactVoltage(V)
Lifecurve
00
FTR-H2
50
AC250V/DC30V
AC250V Cosφ=0.7
20
DC30V τ=7ms
0
5
AC250V Cosφ=0.4
DC30V τ=15mS
2
0
2
4
6
8
0
2
4
Contactcurrentload(A)
n REFERENCE DATA
Distributionofoperate
&releasevoltage
00
Distributionofcontactresistance
00
FTR-H2AA02T
N=00
90
80
release
70
FTR-H2AK02T
N=00
80
Distribution(%)
Distribution(%)
operate
60
50
40
30
make
60
40
20
20
0
0
0
0
0
20
30
40
50
60
70
80
Nominalvoltagemult.factor(%)
0
2
4
6
8
0
2
4
Contact resistance (mΩ)
FTR-H2 Series
nDIMENSIONS
11.0+0.3(.433+.012)
24.0 +0.3(.945+.012)
l PC board mounting
hole layout
(BOTTOM VIEW)
l Schematics
(BOTTOM VIEW)
2
2-Ø 0.9(.035)
4
1.8(.071)
0.35(.014)
16.5 (.650
0.4(.016)
3.5(.138)
3
Orientation Mark
3.3
(.138)
f0.5(.020)
2-Ø1.3(.051)
7.5(.295)
0.5(.020)
25.0 +0.3(.984+.012)
1
1.75(.069)
l Dimensions
De-energized condition
1.75(.069)
1.0(.039)
7.5(.295)
1.8(.071)
16.5(.650)
3.5(.138)
Unit: mm (in.)
FTR-H2 Series
RoHS Compliance and Lead Free Relay Information
1. General Information
Relays produced after the specific date code that is indicated on each data sheet are lead-free
now. Most of our signal and power relays are lead-free. Please refer to Lead-Free Status Info.
(http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf)
l Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu.
l All signal and most power relays also comply with RoHS. Please refer to individual data
sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that
are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE).
l It has been verified that using lead-free relays in leaded assembly process will not cause any
problems (compatible).
l “LF” is marked on each outer and inner carton. (No marking on individual relays).
l To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office. l We will ship leaded relays as long as the leaded relay inventory exists.
Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC)
l
2. Recommended Lead Free Solder Profile
l
Recommended solder paste Sn-3.0Ag-0.5Cu.
Reflow Solder condition
Flow Solder condition:
Pre-heating:
Soldering:
maximum 120˚C
dip within 5 sec. at 260˚C soler bath
Solder by Soldering Iron:
Soldering Iron
Temperature: maximum 360˚C
Duration:
maximum 3 sec.
We highly recommend that you confirm your actual solder conditions
3. Moisture Sensitivity
l
Moisture Sensitivity Level standard is not applicable to electromechanical realys.
4. Tin Whisker
l
Dipped SnAgCu solder is known as low risk tin whisker. No considerable length whisker was found by our in
house test.
FTR-H2 Series
Fujitsu Components International Headquarter Offices
Japan
Fujitsu Component Limited
Gotanda-Chuo Building
3-5, Higashigotanda 2-chome, Shinagawa-ku
Tokyo 141, Japan
Tel: (81-3) 5449-7010
Fax: (81-3) 5449-2626
Email: [email protected]
Web: www.fcl.fujitsu.com
Europe
Fujitsu Components Europe B.V.
Diamantlaan 25
2132 WV Hoofddorp
Netherlands
Tel: (31-23) 5560910
Fax: (31-23) 5560950
Email: [email protected]
Web: emea.fujitsu.com/components/
North and South America
Fujitsu Components America, Inc.
250 E. Caribbean Drive
Sunnyvale, CA 94089 U.S.A.
Tel: (1-408) 745-4900
Fax: (1-408) 745-4970
Email: [email protected]
Web: http://www.fujitsu.com/us/services/edevices/components/
Asia Pacific
Fujitsu Components Asia Ltd.
102E Pasir Panjang Road
#01-01 Citilink Warehouse Complex
Singapore 118529
Tel: (65) 6375-8560
Fax: (65) 6273-3021
Email: [email protected]
Web: http://www.fujitsu.com/sg/services/micro/components/
©2008 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective
owners.
Fujitsu Components America or its affiliates do not warrant that the content of datasheet is error free. In a continuing effort to improve our
products Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets without prior notice.
Rev. January 9, 2008.