FTR-K1 SERIES POWER RELAY 1 POLE - 16A 105ºC FTR-K1 Series RoHS compliant n FEATURES Low profile (height: 15.7mm) l HIGH ISOLATION Insulation Distance (between coil and contacts): 10mm min. Dielectric strength: 5KV Surge strength: 10KV l Low coil power (400mW) l Cadmium free contacts l SAFETY STANDARDS UL, CSA, VDE, SEMKO approved UL, CSA TV-5 rating approved (1 form A type) l RoHS Compliant l UL F class isolation wire l VDE Glow-wire ignitablility test 775 (IEC60335-1) approved l n ORDERING INFORMATION [Example] FTR-K1 C K 005 W – HT (a) (b) (c) (d) (e) (f ) (a) Series Name FTR-K1: FTR-K1 Series (b) Contact Arrangement A C : 1 form A (SPST-NO) : 1 form C (SPDT) (c) Coil Type / Enclosure K : Standard (400 mW) / flux free (d) Nominal Voltage 005 018 048 : 5 VDC, : 18 VDC : 48VDC (e) Contact Material / TV type W T : AgSnO2 (1 form C) : AgSnO2 / TV-5 rated (1form A TV-5) (f) Special Designation HT : 105ºC 006 : 6VDC, 022 :022VDC 009 : 9VDC 024 : 24VDC, 012 : 12VDC 028 : 28VDC Actual marking does not carry the type name : "FTR" E.g.: Ordering code: FTR-K1CK012W Actual marking: K1CK012W FTR-K1 SERIES n PART NUMBERS 400mW type Ordering Part Number Series Contact Coil Power Coil Voltage FTR-K1AK005T-HT 5 FTR-K1AK006T-HT 6 FTR-K1AK009T-HT 9 FTR-K1AK012T-HT 12 A: 1 form A FTR-K1AK018T-HT K: 400 mW 18 FTR-K1AK022T-HT 22 FTR-K1AK024T-HT 24 FTR-K1AK028T-HT 28 FTR-K1AK048T-HT FTR-K1CK005W-HT K: 430 mW FTR-K1 T: AgSnO2 48 5 FTR-K1CK006W-HT 6 FTR-K1CK009W-HT 9 FTR-K1CK012W-HT C: 1 form C FTR-K1CK018W-HT Contact Material K: 400 mW 12 18 FTR-K1CK022W-HT 22 FTR-K1CK024W-HT 24 FTR-K1CK028W-HT 28 FTR-K1CK048W-HT K: 430 mW W: AgSnO2 48 n COIL DATA CHART Coil Voltage Nominal Voltage (VDC) Max. Coil Voltage*1 Coil Resistance (±10%) Must Operate Voltage*2 Must Release Voltage*2 005 5 12.2 VDC 62 Ω 3.5 VDC 0.5 VDC 006 6 14.7 VDC 90 Ω 4.2 VDC 0.6 VDC 009 9 22.0 VDC 202 Ω 6.3 VDC 0.9 VDC 012 12 29.4 VDC 360 Ω 8.4 VDC 1.2 VDC 018 18 44.1 VDC 810 Ω 12.6 VDC 1.8 VDC 022 22 53.9 VDC 1,210 Ω 15.4 VDC 2.2 VDC 024 24 58.8 VDC 1,440 Ω 16.8 VDC 2.4 VDC 028 28 68.6 VDC 1,960 Ω 19.6 VDC 2.8 VDC 048 48 117.6 VDC 5,360 Ω 33.6 VDC 4.8 VDC Nominal Power (mW) 400 430 Note: All values in the table are measured at 20°C. *1: No contact current at 20°C *2: Specified values are subject to pulse wave voltage FTR-K1 SERIES n SPECIFICATIONS Item FTR-K1 AK ( ) T-HT Standard FTR-K1 CK ( )W-HT Standard Contact Arrangement 1 form A 1 from C Material AgSnO2 Resistance (initial) Maximum 100 mΩ at 1 A, 6 VDC Rating 16 A, 250 VAC / 24 VDC Maximum Carrying Current*1 16 A Maximum Inrush Current 80A (20ms) 250VAC Maximum Switching Rating 4,000 VA / 384W Maximum Switching Voltage 440 VAC / 300VDC Minimum Switching Load*2 10 mA 5 VDC Nominal Power (at 20ºC) 400mW (at 430mW 48V coil) Operate Power (at 20ºC) 200 mW (210mW at 48V coil) Operating Temperature -40ºC to +105ºC (no frost) Time Value Operate (without diode) Maximum 15ms (at nominal voltage, no bounce) Release (without diode) Maximum 5ms (at nominal voltage, no bounce) Life Mechanical 20 x 106 operations minimum Coil AC Contact rating 100 x 103 operations min. 50 x 103 operations min. DC contact rating 100 x 103 operations min. 30 x 103 operations min. Vibration Resistance Misoperation 10 to 55 Hz, at double amplitude of 0.7 mm Endurance 10-55Hz, at double amplitude of 1.5 mm Shock Resistance Misoperation Electrical Other Weight Endurance Min. 100m/s2 (11±1ms) Min. 1,000m/s2 (6±1ms) Approximately 13g *1 Need to consider the heat from PCB when max. current is more than 10A. *2 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels. FTR-K1 SERIES n INSULATION Item FTR-K1 Note Resistance (initial) Minimum 1,000 MΩ 1 min. at 500 VDC Dielectric Strength open contacts 1,000 VAC (50/60 Hz) 1 min. coil and contacts 5,000 VAC (50/60 Hz) 1 min. Surge Voltage (coil and contact) 10,000 V Clearance/Creepage 10 mm / 10 mm Insulation (DIN EN61810-1 VDE0435) Voltage Pollution Isolation material group 250 V 3 IIIa 1.2 x 50µs standard wave Isolation category / Reference voltage (VDE0110b) C / 250 V n SAFETY STANDARDS Type Compliance Contact rating FTR-K1CK ( ) W-HT UL UL 508 E63614 CSA C22.2 No. 14 LR 40304 VDE 0435, 0631, 0700, 0860 SEMKO EN 61058-1:1992 and A1 EN 61095:1993 and A1+A11 FTR-K1AK ( ) T-HT Flammability: UL 94-V0 (plastics) 16A, 277 VAC (resistive) 105ºC 16A, 24 VDC (resistive) 105ºC 1 HP, 277VAC 105ºC 1/2 HP, 125VAC 105ºC TV-5, 120VAC, 25,000 cycles, 105ºC Pilot duty: A300 105ºC 16A, 24 VDC (resistive) 105ºC 16A, 277 VAC (resistive) 105ºC 1 HP, 277VAC 105ºC 1/2 HP, 125VAC 105ºC 1/8 HP, 125VAC 105ºC Pilot duty: B300 105ºC 16A, 24VDC (resistive) 16A, 277 VAC (resistive) 20A 277VAC (resistive) 1 HP, 277VAC 1/2 HP, 125VAC TV-5, 120VAC 25,000 cycles Pilot duty: A300 16A, 24VDC (resistive) 16A, 277 VAC (resistive) 20A 277VAC (resistive) 1 HP, 277VAC 1/2 HP, 125VAC 1/8 HP, 125VAC Pilot duty: B300 250VAC, 16 (3)A 40T85 5A/80A 250VAC 40T85 Complies with NEMKO, DEMKO, FIMKO FTR-K1 SERIES n CHARACTERISTIC DATA 6A 70 60 0A 50 40 30 0A 20 0 0 0 0.2 0.4 0.6 0.8 1.2 FTR-K 2 0A 6A 1.5 mu 0.5 FTR-KAK 250VACcosφ=0.7 300 200 00 50 DC24Vτ=7ms 30 20 AC250Vcosφ=0.4 DC24Vτ=15ms 0 2 4 6 8 0 2 4 6 8 20 ContactCurrentLoad(A) ServiceLife(03operations) ServiceLife(03operations) 500 0 20 40 60 80 00 200 50 30 20 4 6 0 20 50 00 200 500 000 FTR-KCK02W n=200 Operate Release 70 60 50 40 30 20 24VDCτ=15ms 2 DCresistive 0.2 80 250VACcosφ=0.4 24VDCτ=7ms 0 0.5 90 00 0 2 00 250VAVcosφ=0.7 24VDCresistive 300 5 DistributionofOperation& ReleaseVoltage 250VACresistiveFTR-KCK 500 0 ContactVoltage(V) LifeCurve 000 FTR-K ACresistive 20 0.1 Ambienttemperature(ºC) LifeCurve 250VACresistive 24VDCresistive coil) ge(cool ratevolta mustope 0 coil) ge(hot tevolta stopera CoilPower(W) 000 MaximumSwitchingPower 50 SwitchingCurrent(A) 80 OperatingRange 2.5 Distribution(%) TemperatureRise(deg.) 90 Nominalvoltagemultiplyingfactor CoilTemperatureRise 00 8 0 0 2 4 6 8 20 ContactCurrentLoad(A) 0 0 0 20 30 40 50 60 70 80 NominalVoltageMultiplyingFactor 90 Distribution(%) 80 Release 70 FTR-KCK02W n=200 Make 90 Operate 80 60 50 40 30 20 Break 70 60 50 40 30 20 0 0 DistributionofContactResistance 00 FTR-KCK02W n=200 Distribution(%) 00 DistributionofOperation& ReleaseTime 0 0 1 2 3 4 5 6 Time(ms) 7 8 9 0 0 0 0 20 30 40 ContactResistance(mΩ) 50 FTR-K1 SERIES n DIMENSIONS l Dimensions l Schematics (BOTTOM VIEW) FTR-K1AK ( ) T-HT 5 12.7 +0.3 15.7 +0.3 29 +0.3 6 4 7 8 COM NO COM NO 2 3 φ 0.45 (2.6) 0.3 20 0.5 3.3 Orientationmark 5 2.6 l PC board mounting hole layout (BOTTOM VIEW) 0.9 0.9 7.5 (2.6) 5 20 4-Ø1.3 7.5 (2.6) 2-Ø ±0.1 l Dimensions l Schematics (BOTTOM VIEW) FTR-K1CK ( ) W-HT 5 15.7 +0.3 7 6 12.7 +0.3 29 +0.3 8 NC COM NO NC COM NO 4 2 3 0.3 5 (2.6) 20 5 0.9 0.9 2.6 7.5 l PC board mounting hole layout (BOTTOM VIEW) (2.6) 20 2-φ1 ±0.1 6-φ1.3 -0 5 5 (2.6) 0.5 0.5 7.5 φ 0.45 3.3 Orientationmark Unit: mm FTR-K1 SERIES RoHS Compliance and Lead Free Relay Information 1. General Information Relays produced after the specific date code that is indicated on each data sheet are lead-free now. All of our signal and power relays are lead-free. Please refer to Lead-Free Status Info. (http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf) l Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu. l All signal and power relays also comply with RoHS. Please refer to individual data sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE, DecaBDE). l It has been verified that using lead-free relays in leaded assembly process will not cause any problems (compatible). l “LF” is marked on each outer and inner carton. (No marking on individual relays). l To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office. l We will ship leaded relays as long as the leaded relay inventory exists. Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC) l 2. Recommended Lead Free Solder Profile l Recommended solder paste Sn-3.0Ag-0.5Cu. Solder condition Flow Solder condition: Pre-heating: Soldering: maximum 120˚C dip within 5 sec. at 260˚C solder bath Solder by Soldering Iron: Soldering Iron Temperature: maximum 360˚C Duration: maximum 3 sec. We highly recommend that you confirm your actual solder conditions 3. Moisture Sensitivity l Moisture Sensitivity Level standard is not applicable to electromechanical relays. 4. Tin Whisker l Dipped SnAgCu solder is known as low risk tin whisker. No considerable length whisker was found by our in house test. FTR-K1 SERIES Fujitsu Components International Headquarter Offices Japan Fujitsu Component Limited Gotanda-Chuo Building 3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141, Japan Tel: (81-3) 5449-7010 Fax: (81-3) 5449-2626 Email: [email protected] Web: www.fcl.fujitsu.com Europe Fujitsu Components Europe B.V. Diamantlaan 25 2132 WV Hoofddorp Netherlands Tel: (31-23) 5560910 Fax: (31-23) 5560950 Email: [email protected] Web: emea.fujitsu.com/components/ North and South America Fujitsu Components America, Inc. 250 E. Caribbean Drive Sunnyvale, CA 94089 U.S.A. Tel: (1-408) 745-4900 Fax: (1-408) 745-4970 Email: [email protected] Web: http://www.fujitsu.com/us/services/edevices/components/ Asia Pacific Fujitsu Components Asia Ltd. 102E Pasir Panjang Road #01-01 Citilink Warehouse Complex Singapore 118529 Tel: (65) 6375-8560 Fax: (65) 6273-3021 Email: [email protected] Web: http://www.fujitsu.com/sg/services/micro/components/ ©2008 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective owners. Fujitsu Components America or its affiliates do not warrant that the content of datasheet is error free. In a continuing effort to improve our products Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets without prior notice. Rev. July 21, 2008.