FUJITSU FTR-K1CK012T-HT

FTR-K1 SERIES
POWER RELAY
1 POLE - 16A 105ºC
FTR-K1 Series
RoHS compliant
n FEATURES
Low profile (height: 15.7mm)
l
HIGH ISOLATION
Insulation Distance (between coil and contacts): 10mm min.
Dielectric strength: 5KV
Surge strength: 10KV
l
Low coil power (400mW)
l
Cadmium free contacts
l
SAFETY STANDARDS
UL, CSA, VDE, SEMKO approved
UL, CSA TV-5 rating approved (1 form A type)
l
RoHS Compliant
l
UL F class isolation wire
l
VDE Glow-wire ignitablility test 775 (IEC60335-1) approved
l
n ORDERING INFORMATION
[Example]
FTR-K1 C K 005 W – HT (a)
(b) (c) (d) (e) (f )
(a)
Series Name FTR-K1: FTR-K1 Series
(b)
Contact Arrangement
A
C
: 1 form A (SPST-NO)
: 1 form C (SPDT)
(c)
Coil Type / Enclosure
K
: Standard (400 mW) / flux free
(d)
Nominal Voltage
005 018
048 : 5 VDC,
: 18 VDC
: 48VDC
(e)
Contact Material / TV type
W
T
: AgSnO2 (1 form C)
: AgSnO2 / TV-5 rated (1form A TV-5)
(f)
Special Designation
HT
: 105ºC
006 : 6VDC,
022 :022VDC
009 : 9VDC
024 : 24VDC, 012 : 12VDC
028 : 28VDC Actual marking does not carry the type name : "FTR"
E.g.: Ordering code: FTR-K1CK012W
Actual marking: K1CK012W
FTR-K1 SERIES
n PART NUMBERS
400mW type
Ordering Part Number
Series
Contact
Coil Power
Coil
Voltage
FTR-K1AK005T-HT
5
FTR-K1AK006T-HT
6
FTR-K1AK009T-HT
9
FTR-K1AK012T-HT
12
A: 1 form A
FTR-K1AK018T-HT
K: 400 mW
18
FTR-K1AK022T-HT
22
FTR-K1AK024T-HT
24
FTR-K1AK028T-HT
28
FTR-K1AK048T-HT
FTR-K1CK005W-HT
K: 430 mW
FTR-K1
T: AgSnO2
48
5
FTR-K1CK006W-HT
6
FTR-K1CK009W-HT
9
FTR-K1CK012W-HT
C: 1 form C
FTR-K1CK018W-HT
Contact Material
K: 400 mW
12
18
FTR-K1CK022W-HT
22
FTR-K1CK024W-HT
24
FTR-K1CK028W-HT
28
FTR-K1CK048W-HT
K: 430 mW
W: AgSnO2
48
n COIL DATA CHART
Coil
Voltage
Nominal
Voltage
(VDC)
Max. Coil
Voltage*1
Coil
Resistance
(±10%)
Must Operate
Voltage*2
Must
Release Voltage*2
005
5
12.2 VDC
62 Ω
3.5 VDC
0.5 VDC
006
6
14.7 VDC
90 Ω
4.2 VDC
0.6 VDC
009
9
22.0 VDC
202 Ω
6.3 VDC
0.9 VDC
012
12
29.4 VDC
360 Ω
8.4 VDC
1.2 VDC
018
18
44.1 VDC
810 Ω
12.6 VDC
1.8 VDC
022
22
53.9 VDC
1,210 Ω
15.4 VDC
2.2 VDC
024
24
58.8 VDC
1,440 Ω
16.8 VDC
2.4 VDC
028
28
68.6 VDC
1,960 Ω
19.6 VDC
2.8 VDC
048
48
117.6 VDC
5,360 Ω
33.6 VDC
4.8 VDC
Nominal Power
(mW)
400
430
Note: All values in the table are measured at 20°C.
*1: No contact current at 20°C
*2: Specified values are subject to pulse wave voltage
FTR-K1 SERIES
n SPECIFICATIONS
Item
FTR-K1 AK ( ) T-HT
Standard
FTR-K1 CK ( )W-HT
Standard
Contact Arrangement
1 form A
1 from C
Material
AgSnO2
Resistance (initial)
Maximum 100 mΩ at 1 A, 6 VDC
Rating
16 A, 250 VAC / 24 VDC
Maximum Carrying Current*1
16 A
Maximum Inrush Current
80A (20ms) 250VAC
Maximum Switching Rating
4,000 VA / 384W
Maximum Switching Voltage
440 VAC / 300VDC
Minimum Switching Load*2
10 mA 5 VDC
Nominal Power (at 20ºC)
400mW (at 430mW 48V coil)
Operate Power (at 20ºC)
200 mW (210mW at 48V coil)
Operating Temperature
-40ºC to +105ºC (no frost)
Time
Value
Operate (without diode)
Maximum 15ms (at nominal voltage, no bounce)
Release (without diode)
Maximum 5ms (at nominal voltage, no bounce)
Life
Mechanical
20 x 106 operations minimum
Coil
AC Contact rating
100 x 103 operations min.
50 x 103 operations min.
DC contact rating
100 x 103 operations min.
30 x 103 operations min.
Vibration
Resistance
Misoperation
10 to 55 Hz, at double amplitude of 0.7 mm
Endurance
10-55Hz, at double amplitude of 1.5 mm
Shock
Resistance
Misoperation
Electrical
Other
Weight
Endurance
Min. 100m/s2 (11±1ms)
Min. 1,000m/s2 (6±1ms)
Approximately 13g
*1 Need to consider the heat from PCB when max. current is more than 10A.
*2 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual
load before production since reference values may vary according to switching frequencies, environmental conditions
and expected reliability levels.
FTR-K1 SERIES
n
INSULATION
Item
FTR-K1
Note
Resistance (initial)
Minimum 1,000 MΩ 1 min.
at 500 VDC
Dielectric
Strength
open contacts
1,000 VAC (50/60 Hz) 1 min.
coil and contacts
5,000 VAC (50/60 Hz) 1 min.
Surge Voltage (coil and contact)
10,000 V
Clearance/Creepage
10 mm / 10 mm
Insulation (DIN EN61810-1 VDE0435)
Voltage
Pollution
Isolation material group
250 V
3
IIIa
1.2 x 50µs standard wave
Isolation category / Reference voltage (VDE0110b) C / 250 V
n SAFETY STANDARDS
Type
Compliance
Contact rating
FTR-K1CK ( ) W-HT
UL
UL 508
E63614
CSA
C22.2 No. 14
LR 40304
VDE
0435, 0631, 0700, 0860
SEMKO EN 61058-1:1992 and A1
EN 61095:1993 and
A1+A11
FTR-K1AK ( ) T-HT
Flammability: UL 94-V0 (plastics)
16A, 277 VAC (resistive) 105ºC
16A, 24 VDC (resistive) 105ºC
1 HP, 277VAC 105ºC
1/2 HP, 125VAC 105ºC
TV-5, 120VAC, 25,000 cycles, 105ºC
Pilot duty: A300 105ºC
16A, 24 VDC (resistive) 105ºC
16A, 277 VAC (resistive) 105ºC
1 HP, 277VAC 105ºC
1/2 HP, 125VAC 105ºC
1/8 HP, 125VAC 105ºC
Pilot duty: B300 105ºC
16A, 24VDC (resistive)
16A, 277 VAC (resistive)
20A 277VAC (resistive)
1 HP, 277VAC
1/2 HP, 125VAC
TV-5, 120VAC 25,000 cycles
Pilot duty: A300
16A, 24VDC (resistive)
16A, 277 VAC (resistive)
20A 277VAC (resistive)
1 HP, 277VAC
1/2 HP, 125VAC
1/8 HP, 125VAC
Pilot duty: B300
250VAC, 16 (3)A 40T85
5A/80A 250VAC 40T85
Complies with NEMKO, DEMKO, FIMKO
FTR-K1 SERIES
n CHARACTERISTIC DATA
6A
70
60
0A
50
40
30
0A
20
0
0
0
0.2
0.4
0.6
0.8
1.2
FTR-K
2
0A
6A
1.5
mu
0.5
FTR-KAK
250VACcosφ=0.7
300
200
00
50
DC24Vτ=7ms
30
20
AC250Vcosφ=0.4
DC24Vτ=15ms
0
2
4
6
8
0 2 4 6 8 20
ContactCurrentLoad(A)
ServiceLife(03operations)
ServiceLife(03operations)
500
0
20
40
60
80
00
200
50
30
20
4
6
0
20
50
00
200
500 000
FTR-KCK02W
n=200
Operate
Release
70
60
50
40
30
20
24VDCτ=15ms
2
DCresistive
0.2
80
250VACcosφ=0.4
24VDCτ=7ms
0
0.5
90
00
0
2
00
250VAVcosφ=0.7
24VDCresistive
300
5
DistributionofOperation&
ReleaseVoltage
250VACresistiveFTR-KCK
500
0
ContactVoltage(V)
LifeCurve
000
FTR-K
ACresistive
20
0.1
Ambienttemperature(ºC)
LifeCurve
250VACresistive
24VDCresistive
coil)
ge(cool
ratevolta
mustope
0
coil)
ge(hot
tevolta
stopera
CoilPower(W)
000
MaximumSwitchingPower
50
SwitchingCurrent(A)
80
OperatingRange
2.5
Distribution(%)
TemperatureRise(deg.)
90
Nominalvoltagemultiplyingfactor
CoilTemperatureRise
00
8
0
0 2 4 6 8 20
ContactCurrentLoad(A)
0
0
0
20
30
40
50
60
70
80
NominalVoltageMultiplyingFactor
90
Distribution(%)
80
Release
70
FTR-KCK02W
n=200
Make
90
Operate
80
60
50
40
30
20
Break
70
60
50
40
30
20
0
0
DistributionofContactResistance
00
FTR-KCK02W
n=200
Distribution(%)
00
DistributionofOperation&
ReleaseTime
0
0
1
2
3
4
5
6
Time(ms)
7
8
9
0
0
0
0
20
30
40
ContactResistance(mΩ)
50
FTR-K1 SERIES
n DIMENSIONS
l Dimensions
l Schematics
(BOTTOM VIEW)
FTR-K1AK ( ) T-HT
5
12.7 +0.3
15.7 +0.3
29 +0.3
6
4
7
8
COM
NO
COM
NO
2
3
φ 0.45
(2.6)
0.3
20
0.5
3.3
Orientationmark
5
2.6
l PC board mounting
hole layout
(BOTTOM VIEW)
0.9
0.9
7.5
(2.6)
5
20
4-Ø1.3
7.5
(2.6)
2-Ø ±0.1
l Dimensions
l Schematics
(BOTTOM VIEW)
FTR-K1CK ( ) W-HT
5
15.7 +0.3
7
6
12.7 +0.3
29 +0.3
8
NC COM
NO
NC COM
NO
4
2
3
0.3
5
(2.6)
20
5
0.9
0.9
2.6
7.5
l PC board mounting
hole layout
(BOTTOM VIEW)
(2.6)
20
2-φ1
±0.1
6-φ1.3
-0
5
5
(2.6)
0.5
0.5
7.5
φ 0.45
3.3
Orientationmark
Unit: mm
FTR-K1 SERIES
RoHS Compliance and Lead Free Relay Information
1. General Information
Relays produced after the specific date code that is indicated on each data sheet are lead-free
now. All of our signal and power relays are lead-free. Please refer to Lead-Free Status Info.
(http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf)
l Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu.
l All signal and power relays also comply with RoHS. Please refer to individual data
sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that
are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE, DecaBDE).
l It has been verified that using lead-free relays in leaded assembly process will not cause any
problems (compatible).
l “LF” is marked on each outer and inner carton. (No marking on individual relays).
l To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office. l We will ship leaded relays as long as the leaded relay inventory exists.
Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC)
l
2. Recommended Lead Free Solder Profile
l
Recommended solder paste Sn-3.0Ag-0.5Cu.
Solder condition
Flow Solder condition:
Pre-heating:
Soldering:
maximum 120˚C
dip within 5 sec. at 260˚C solder bath
Solder by Soldering Iron:
Soldering Iron
Temperature: maximum 360˚C
Duration:
maximum 3 sec.
We highly recommend that you confirm your actual solder conditions
3. Moisture Sensitivity
l
Moisture Sensitivity Level standard is not applicable to electromechanical relays.
4. Tin Whisker
l
Dipped SnAgCu solder is known as low risk tin whisker. No considerable length whisker was found by our in
house test.
FTR-K1 SERIES
Fujitsu Components International Headquarter Offices
Japan
Fujitsu Component Limited
Gotanda-Chuo Building
3-5, Higashigotanda 2-chome, Shinagawa-ku
Tokyo 141, Japan
Tel: (81-3) 5449-7010
Fax: (81-3) 5449-2626
Email: [email protected]
Web: www.fcl.fujitsu.com
Europe
Fujitsu Components Europe B.V.
Diamantlaan 25
2132 WV Hoofddorp
Netherlands
Tel: (31-23) 5560910
Fax: (31-23) 5560950
Email: [email protected]
Web: emea.fujitsu.com/components/
North and South America
Fujitsu Components America, Inc.
250 E. Caribbean Drive
Sunnyvale, CA 94089 U.S.A.
Tel: (1-408) 745-4900
Fax: (1-408) 745-4970
Email: [email protected]
Web: http://www.fujitsu.com/us/services/edevices/components/
Asia Pacific
Fujitsu Components Asia Ltd.
102E Pasir Panjang Road
#01-01 Citilink Warehouse Complex
Singapore 118529
Tel: (65) 6375-8560
Fax: (65) 6273-3021
Email: [email protected]
Web: http://www.fujitsu.com/sg/services/micro/components/
©2008 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective
owners.
Fujitsu Components America or its affiliates do not warrant that the content of datasheet is error free. In a continuing effort to improve our
products Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets without prior notice.
Rev. July 21, 2008.