SPANSION S70WS512N00BFWAA3

S70WS512N00 Based MCPs
Same-Die Stacked Multi-Chip Product (MCP)
512 Megabit (32M x 16 bit) CMOS
1.8 Volt-only Simultaneous Read/Write,
Burst-mode Flash Memory
ADVANCE
INFORMATION
Data Sheet
Notice to Readers: This document states the current technical specifications
regarding the Spansion product(s) described herein. Each product described
herein may be designated as Advance Information, Preliminary, or Full
Production. See Notice On Data Sheet Designations for definitions.
Publication Number S70WS512N00_00
Revision A
Amendment 0
Issue Date March 14, 2005
This document contains information on one or more products under development at Spansion LLC. The information is intended to help you evaluate this product. Do not
design in this product without contacting the factory. Spansion LLC reserves the right to change or discontinue work on this proposed product without notice.
A d v a n c e
I n f o r m a t i o n
This page intentionally left blank.
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
S70WS512N00 Based MCPs
Same-Die Stacked Multi-Chip Product (MCP)
512 Megabit (32M x 16 bit) CMOS
1.8 Volt-only Simultaneous Read/Write,
Burst-mode Flash Memory
ADVANCE
INFORMATION
General Description
The S70WS512N Series is a product line of stacked Multi-Chip Product (MCP) packages and consists of two S29WS-N flash memory die.
Distinctive Characteristics
MCP Features
„ Power supply voltage of 1.7 V to 1.95 V
„ Burst Speed: 54 MHz, 66 MHz
„ Package
— 8 x 11.6 mm
„ Operating Temperature
— Wireless, –25°C to +85°C
Publication Number S70WS512N00_00
Revision A
Amendment 0
Issue Date March 14, 2005
This document contains information on one or more products under development at Spansion LLC. The information is intended to help you evaluate this product. Do
not design in this product without contacting the factory. Spansion LLC reserves the right to change or discontinue work on this proposed product without notice.
A d v a n c e
I n f o r m a t i o n
Notice On Data Sheet Designations
Spansion LLC issues data sheets with Advance Information or Preliminary designations to advise
readers of product information or intended specifications throughout the product life cycle, including development, qualification, initial production, and full production. In all cases, however,
readers are encouraged to verify that they have the latest information before finalizing their design. The following descriptions of Spansion data sheet designations are presented here to
highlight their presence and definitions.
Advance Information
The Advance Information designation indicates that Spansion LLC is developing one or more specific products, but has not committed any design to production. Information presented in a
document with this designation is likely to change, and in some cases, development on the product may discontinue. Spansion LLC therefore places the following conditions upon Advance
Information content:
“This document contains information on one or more products under development at Spansion LLC. The
information is intended to help you evaluate this product. Do not design in this product without contacting the factory. Spansion LLC reserves the right to change or discontinue work on this proposed
product without notice.”
Preliminary
The Preliminary designation indicates that the product development has progressed such that a
commitment to production has taken place. This designation covers several aspects of the product life cycle, including product qualification, initial production, and the subsequent phases in the
manufacturing process that occur before full production is achieved. Changes to the technical
specifications presented in a Preliminary document should be expected while keeping these aspects of production under consideration. Spansion places the following conditions upon
Preliminary content:
“This document states the current technical specifications regarding the Spansion product(s) described
herein. The Preliminary status of this document indicates that product qualification has been completed,
and that initial production has begun. Due to the phases of the manufacturing process that require
maintaining efficiency and quality, this document may be revised by subsequent versions or modifications due to changes in technical specifications.”
Combination
Some data sheets will contain a combination of products with different designations (Advance Information, Preliminary, or Full Production). This type of document will distinguish these products
and their designations wherever necessary, typically on the first page, the ordering information
page, and pages with the DC Characteristics table and the AC Erase and Program table (in the
table notes). The disclaimer on the first page refers the reader to the notice on this page.
Full Production (No Designation on Document)
When a product has been in production for a period of time such that no changes or only nominal
changes are expected, the Preliminary designation is removed from the data sheet. Nominal
changes may include those affecting the number of ordering part numbers available, such as the
addition or deletion of a speed option, temperature range, package type, or VIO range. Changes
may also include those needed to clarify a description or to correct a typographical error or incorrect specification. Spansion LLC applies the following conditions to documents in this category:
“This document states the current technical specifications regarding the Spansion product(s) described
herein. Spansion LLC deems the products to have been in sufficient production volume such that subsequent versions of this document are not expected to change. However, typographical or specification
corrections, or modifications to the valid combinations offered may occur.”
Questions regarding these document designations may be directed to your local AMD or Fujitsu
sales office.
2
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Contents
S70WS512N00 Based MCPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1
2
3
4
5
Product Selector Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Input/Output Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
MCP Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Connection Diagrams/Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1 Special Handling Instructions for FBGA Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
5.2 Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
5.2.1 Same-Die Stack Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
5.2.2 Look-Ahead Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.3 Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
5.3.1 TSB084—84-ball Fine-Pitch Ball Grid Array (FBGA) 11.6 x 8.0 x 1.2 mm . . . . . . . . . . . . . . . . . . . . . . . . .16
S29WS-N MirrorBit™ Flash Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6
7
8
9
Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7.1 Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Device Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8.1 Device Operation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8.2 Asynchronous Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8.3 Synchronous (Burst) Read Mode and Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
8.3.1 Continuous Burst Read Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8.3.2 8-, 16-, 32-Word Linear Burst Read with Wrap Around . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8.3.3 8-, 16-, 32-Word Linear Burst without Wrap Around . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8.3.4 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8.4 Autoselect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8.5 Program/Erase Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8.5.1 Single Word Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8.5.2 Write Buffer Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
8.5.3 Sector Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
8.5.4 Chip Erase Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8.5.5 Erase Suspend/Erase Resume Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8.5.6 Program Suspend/Program Resume Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
8.5.7 Accelerated Program/Chip Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
8.5.8 Unlock Bypass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8.5.9 Write Operation Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
8.6 Simultaneous Read/Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.7 Writing Commands/Command Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.8 Handshaking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.9 Hardware Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.10 Software Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Advanced Sector Protection/Unprotection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
9.1 Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
9.2 Persistent Protection Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
9.3 Dynamic Protection Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
9.4 Persistent Protection Bit Lock Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
9.5 Password Protection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
9.6 Advanced Sector Protection Software Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.7 Hardware Data Protection Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.7.1 WP# Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.7.2 ACC Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.7.3 Low VCC Write Inhibit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.7.4 Write Pulse Glitch Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
3
A d v a n c e
I n f o r m a t i o n
9.7.5 Power-Up Write Inhibit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
10 Power Conservation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
10.1 Standby Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
10.2 Automatic Sleep Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
10.3 Hardware RESET# Input Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
10.4 Output Disable (OE#). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
11 Secured Silicon Sector Flash Memory Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
11.1 Factory Secured SiliconSector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
11.2 Customer Secured Silicon Sector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
11.3 Secured Silicon Sector Entry and Secured Silicon Sector Exit Command Sequences. . . . . . . . . . . . . . . . . . . . . 62
12 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
12.1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
12.2 Operating Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
12.3 Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
12.4 Key to Switching Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
12.5 Switching Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
12.6 VCC Power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
12.7 DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
12.8 AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
12.8.1 CLK Characterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
12.8.2 Synchronous/Burst Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
12.8.3 Timing Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
12.8.4 AC Characteristics—Asynchronous Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
12.8.5 Hardware Reset (RESET#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
12.8.6 Erase/Program Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
12.8.7 Erase and Programming Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
12.8.8 BGA Ball Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
13 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
13.1 Common Flash Memory Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
14 Commonly Used Terms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
15 Revisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
4
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Tables
Table 2.1
MCP Configurations and Valid Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 3.1
Input/Output Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 7.1
S29WS256N Sector & Memory Address Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 7.2
S29WS128N Sector & Memory Address Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 7.3
S29WS064N Sector & Memory Address Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 8.1
Device Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 8.2
Address Latency (S29WS256N) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 8.3
Address Latency (S29WS128N/S29WS064N) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 8.4
Address/Boundary Crossing Latency (S29WS256N @ 80/66 MHz). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 8.5
Address/Boundary Crossing Latency (S29WS256N @ 54MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 8.6
Address/Boundary Crossing Latency (S29WS128N/S29WS064N) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 8.7
Burst Address Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 8.8
Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 8.9
Autoselect Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 8.10
Autoselect Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 8.11
Autoselect Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 8.12
Single Word Program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 8.13
Write Buffer Program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 8.14
Sector Erase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 8.15
Chip Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 8.16
Erase Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 8.17
Erase Resume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 8.18
Program Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 8.19
Program Resume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 8.20
Unlock Bypass Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 8.21
Unlock Bypass Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 8.22
Unlock Bypass Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 8.23
Write Operation Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Table 8.24
Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 9.1
Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 9.2
Sector Protection Schemes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table 11.1
Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 11.2
Secured Silicon Sector Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 11.3
Secured Silicon Sector Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 11.4
Secured Silicon Sector Exit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 12.1
Test Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table 13.1
Memory Array Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Table 13.2
Sector Protection Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Table 13.3
CFI Query Identification String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Table 13.4
System Interface String. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Table 13.5
Device Geometry Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Table 13.6
Primary Vendor-Specific Extended Query . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
5
A d v a n c e
I n f o r m a t i o n
Figures
Figure 8.1
Figure 8.2
Synchronous/Asynchronous State Diagram...........................................................................................23
Synchronous Read ............................................................................................................................26
Figure 8.3
Single Word Program.........................................................................................................................32
Figure 8.4
Write Buffer Programming Operation ...................................................................................................36
Figure 8.5
Sector Erase Operation ......................................................................................................................38
Figure 8.6
Write Operation Status Flowchart ........................................................................................................45
Figure 9.1
Figure 9.2
Advanced Sector Protection/Unprotection .............................................................................................51
PPB Program/Erase Algorithm .............................................................................................................54
Figure 9.3
Lock Register Program Algorithm.........................................................................................................57
Figure 12.1
Figure 12.2
Maximum Negative Overshoot Waveform .............................................................................................64
Maximum Positive Overshoot Waveform ...............................................................................................64
Figure 12.3
Test Setup .......................................................................................................................................65
Figure 12.4
Input Waveforms and Measurement Levels ...........................................................................................65
Figure 12.5
VCC Power-up Diagram ......................................................................................................................66
Figure 12.6
CLK Characterization .........................................................................................................................68
Figure 12.7
CLK Synchronous Burst Mode Read......................................................................................................69
Figure 12.8
8-word Linear Burst with Wrap Around.................................................................................................70
Figure 12.9
8-word Linear Burst without Wrap Around ............................................................................................70
Figure 12.10 Linear Burst with RDY Set One Cycle Before Data ..................................................................................71
Figure 12.11 Asynchronous Mode Read...................................................................................................................72
Figure 12.12 Reset Timings...................................................................................................................................72
Figure 12.13 Chip/Sector Erase Operation Timings ...................................................................................................74
Figure 12.14 Asynchronous Program Operation Timings ............................................................................................75
Figure 12.15 Synchronous Program Operation Timings .............................................................................................76
Figure 12.16 Accelerated Unlock Bypass Programming Timing ...................................................................................76
Figure 12.17 Data# Polling Timings (During Embedded Algorithm) .............................................................................77
Figure 12.18 Toggle Bit Timings (During Embedded Algorithm) ..................................................................................77
Figure 12.19 Synchronous Data Polling Timings/Toggle Bit Timings ............................................................................78
Figure 12.20 DQ2 vs. DQ6 ....................................................................................................................................78
Figure 12.21 Latency with Boundary Crossing when Frequency > 66 MHz....................................................................79
Figure 12.22 Latency with Boundary Crossing into Program/Erase Bank ......................................................................80
Figure 12.23 Example of Wait State Insertion ..........................................................................................................81
Figure 12.24 Back-to-Back Read/Write Cycle Timings ...............................................................................................82
6
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
1
I n f o r m a t i o n
Product Selector Guide
Device
Model
Numbers
Flash
A2
S70WS512N00
A2
A3
Flash
Speed
(MHz)
66 MHz
2 x WS256N
AB
54 Mhz
DYB
Power-Up
State
(See Note)
Package
(mm)
0 (protected)
1 (unprotected)
0 (protected)
TSB084
11.6x8.0x1.2
1 (unprotected)
Note: 0 (Protected), 1 (Unprotected [Default State])
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
7
A d v a n c e
2
I n f o r m a t i o n
Ordering Information
The ordering part number is formed by a valid combination of the following:
S70WS 512
N
0
0
BA
W
A
3
0
Packing
0
=
2
=
3
=
Type
Tray
7” Tape and Reel
13” Tape and Reel
DYB Power Up, Speed Combinations
3
= 0, 54 MHz
B
= 1, 54 MHz
2
= 0, 66 MHz
A
= 1, 66 MHz
Package Modifier
A
= 1.2 mm, 8 x 11.6, 84-ball FBGA (TSB084)
Temperature Range
W
= Wireless (-25°C to +85°C)
Package Type
BA
= Very Thin Fine-Pitch BGA
Lead (Pb)-free Compliant Package
BF
= Very Thin Fine-Pitch BGA
Lead (Pb)-free Package
Chip Contents—2
No content
pSRAM Density
No content
Process Technology
N
= 110nm MirrorBit™ Technology
Flash Density
512
= 512Mb (2x256Mb)
Device Family
S70WS= Multi-Chip Product
1.8 Volt-only Simultaneous Read/Write Burst Mode
Flash Memory Same-Die Stack
Table 2.1
S70WS512N00
MCP Configurations and Valid Combinations
0
Valid Combinations
BA, BF
W
A
2, A, 3, B
Package Marking Note:
The package marking omits the leading S from the ordering part number.
Valid Combinations
Valid Combinations list configurations planned to be supported in volume for this device. Consult
your local sales office to confirm availability of specific valid combinations and to check on newly
released combinations.
8
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
3
I n f o r m a t i o n
Input/Output Descriptions
Table 3.1 identifies the input and output package connections provided on the device.
Table 3.1
Input/Output Descriptions
Symbol
A23-A0
Description
Address inputs
DQ15-DQ0
Data input/output
OE#
Output Enable input. Asynchronous relative to CLK for the Burst mode.
WE#
Write Enable input.
VSS
Ground
NC
No Connect; not connected internally
RDY
Ready output. Indicates the status of the Burst read.
CLK
Clock input. In burst mode, after the initial word is output, subsequent active edges of CLK increment
the internal address counter. Should be at VIL or VIH while in asynchronous mode
AVD#
Address Valid input. Indicates to device that the valid address is present on the address inputs.
Low = for asynchronous mode, indicates valid address; for burst mode, causes starting address to be
latched.
High = device ignores address inputs
F-RST#
Hardware reset input. Low = device resets and returns to reading array data
F-WP#
Hardware write protect input. At VIL, disables program and erase functions in the four outermost
sectors. Should be at VIH for all other conditions.
F-ACC
Accelerated input. At VHH, accelerates programming; automatically places device in unlock bypass
mode. At VIL, disables all program and erase functions. Should be at VIH for all other conditions.
F1-CE#
Chip-enable input for Flash 1. Asynchronous relative to CLK for Burst Mode.
F2-CE#
Chip-enable input for Flash 2. Asynchronous relative to CLK for Burst Mode.
F-VCC
Flash 1.8 Volt-only single power supply.
DNU
Do Not Use
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
9
A d v a n c e
4
I n f o r m a t i o n
MCP Block Diagram
F-RST#
RST#
F-ACC
F-WP#
F1-CE#
F-OE#
F-WE#
AVD#
F-CLK
ACC
WP#
CE#
OE#
WE#
AVD#
CLK
Amax-A0
Amax-A0
FLASH
MEMORY
WS256N
RDY
F-RDY
DQ15-DQ0
DQ15-DQ0
RST#
F2-CE#
ACC
WP#
CE#
OE#
WE#
AVD#
CLK
FLASH
MEMORY
WS256N
RDY
DQ15-DQ0
Amax-A0
10
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
5
I n f o r m a t i o n
Connection Diagrams/Physical Dimensions
This section contains the I/O designations and package specifications for the S70WS512N.
5.1
Special Handling Instructions for FBGA Packages
Special handling is required for Flash Memory products in FBGA packages.
Flash memory devices in FBGA packages may be damaged if exposed to ultrasonic cleaning methods. The package and/or data integrity may be compromised if the package body is exposed to
temperatures above 150°C for prolonged periods of time.
5.2
Connection Diagrams
5.2.1
Same-Die Stack Pinout
84-ball Fine-Pitch Ball Grid Array
Same-Die Stack Pinout (Top View, Balls Facing Down)
Legend
A10
A1
DNU
B2
B3
B4
B5
B6
B7
B8
B9
AVD#
RFU
CLK
F2-CE#
RFU
RFU
RFU
RFU
C2
C3
C4
C5
C6
C7
C8
C9
F-WP#
A7
RFU
F-ACC
WE#
A8
A11
RFU
D2
D3
D4
D5
D6
D7
D8
D9
A3
A6
RFU
F-RST#
RFU
A19
A12
A15
E2
E3
E4
E5
E6
E7
E8
E9
A2
A5
A18
F-RDY
A20
A9
A13
A21
F2
F3
F4
F5
F6
F7
F8
F9
A1
A4
A17
RFU
A23
A10
A14
A22
G2
G3
G4
G5
G6
G7
G8
G9
A0
VSS
DQ1
RFU
RFU
DQ6
RFU
A16
H2
H3
H4
H5
H6
H7
H8
H9
OE#
DQ9
DQ3
DQ4
DQ13
DQ15
RFU
J2
J3
J4
J5
J6
J7
J8
RFU
DQ0
DQ10
F-VCC
RFU
DQ12
DQ7
VSS
K2
K3
K4
K5
K6
K7
K8
K9
RFU
DQ8
DQ2
DQ11
RFU
DQ5
DQ14
RFU
L2
L3
L4
L5
L6
L7
L8
L9
RFU
RFU
RFU
F-VCC
RFU
RFU
RFU
RFU
DNU
Shared
Flash Shared only
1st Flash only
F1-CE#
2nd Flash only
RAM only
RFU
(Reserved for
Future Use)
J9
M1
M10
DNU
DNU
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
11
A d v a n c e
5.2.2
I n f o r m a t i o n
Look-Ahead Connection Diagram
A1
A2
A9
A10
RFU
RFU
RFU
RFU
B1
B2
B9
B10
RFU
RFU
RFU
RFU
Legend:
N1
12
X
RFU
(Reserved for
Future Use)
C2
C3
C4
C5
C6
C7
C8
C9
AVD#
VSS
CLK
F2-CE#
F-VCC
F-CLK#
R-OE#
F2-OE#
X
D2
D3
D4
D5
D6
D7
D8
D9
Code Flash Only
WP#
A7
R-LB#
ACC
WE#
A8
A11
F3-CE#
E2
E3
D4
C7
E6
E7
E8
E9
A3
A6
R-UB#
F-RST#
R1-CE2
A19
A12
A15
F2
F3
F4
F5
F6
F7
F8
F9
A2
A5
A18
RDY/WAIT#
A20
A9
A13
A21
X
Flash/Data
Shared
G2
G3
G4
G5
G6
G7
G8
G9
A1
A4
A17
R2-CE1
A23
A10
A14
A22
H2
H3
H4
H5
H6
H7
H8
H9
A0
VSS
DQ1
R2-VCC
R2-CE2
DQ6
A24
A16
X
MirrorBit Data
Only
X
Flash/xRAM
Shared
J2
J3
J4
J5
J6
J7
J8
J9
F1-CE#
OE#
DQ9
DQ3
DQ4
DQ13
DQ15
R-CRE or
R-MRS
K2
K3
K4
K5
E6
K7
K8
K9
R1-CE1#
DQ0
DQ10
F-VCC
R1-VCC
DQ12
DQ7
VSS
L2
L3
L4
L5
L6
L7
L8
L9
R-VCC
DQ8
DQ2
DQ11
A25
DQ5
DQ14
WP#
M2
M3
M4
M5
M6
M7
M8
M9
A27
A26
VSS
F-VCC
F4-CE#
R-VCCQ
F-VCCQ
R-CLK#
X
pSRAM Only
X
xRAM Shared
N1
N2
N9
N10
F-DQS0
RFU
RFU
F-DQS1
P1
P2
P9
P10
RFU
RFU
RFU
RFU
Notes:
Ball
3.0 V VCC
1.8 V VCC
1.
2.
D2
NC
F-WP#
D5
WP#/ACC
ACC
F5
RY/BY
F-RDY/R-WAIT#
In a 3.0V system, the GL device used as Data has to have WP tied to VCC
F1 and F2 denote XIP/Flash, F3 and F4 denote Data/Companion Flash
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
5.3
I n f o r m a t i o n
Physical Dimensions
5.3.1
TSB084—84-ball Fine-Pitch Ball Grid Array (FBGA) 11.6 x 8.0 x 1.2 mm
D1
A
D
eD
0.15 C
10
(2X)
9
8
SE 7
7
6
E
E1
5
4
eE
3
2
1
M
INDEX MARK
PIN A1
CORNER
B
10
TOP VIEW
L
K
J
H
G
F
E
D
C B
A
PIN A1
CORNER
7
SD
0.15 C
(2X)
BOTTOM VIEW
A A2
0.20 C
A1
C
SIDE VIEW
6
0.08 C
b
84X
0.15
M
C A B
0.08
M
C
NOTES:
PACKAGE
TSB 084
JEDEC
N/A
DxE
11.60 mm x 8.00 mm
PACKAGE
SYMBOL
MIN
NOM
MAX
A
---
---
1.20
A1
0.17
---
---
A2
0.81
---
0.97
NOTE
PROFILE
BODY SIZE
E
8.00 BSC.
BODY SIZE
D1
8.80 BSC.
MATRIX FOOTPRINT
E1
7.20 BSC.
MATRIX FOOTPRINT
MD
12
MATRIX SIZE D DIRECTION
ME
10
MATRIX SIZE E DIRECTION
84
0.35
0.40
2.
ALL DIMENSIONS ARE IN MILLIMETERS.
3.
BALL POSITION DESIGNATION PER JESD 95-1, SPP-010.
4.
e REPRESENTS THE SOLDER BALL GRID PITCH.
5.
SYMBOL "MD" IS THE BALL MATRIX SIZE IN THE "D"
DIRECTION.
SYMBOL "ME" IS THE BALL MATRIX SIZE IN THE
"E" DIRECTION.
BODY THICKNESS
11.60 BSC.
n
DIMENSIONING AND TOLERANCING METHODS PER
ASME Y14.5M-1994.
BALL HEIGHT
D
φb
1.
n IS THE NUMBER OF POPULTED SOLDER BALL POSITIONS
FOR MATRIX SIZE MD X ME.
6
DIMENSION "b" IS MEASURED AT THE MAXIMUM BALL
DIAMETER IN A PLANE PARALLEL TO DATUM C.
7
SD AND SE ARE MEASURED WITH RESPECT TO DATUMS A
AND B AND DEFINE THE POSITION OF THE CENTER SOLDER
BALL IN THE OUTER ROW.
BALL COUNT
0.45
WHEN THERE IS AN ODD NUMBER OF SOLDER BALLS IN THE
OUTER ROW SD OR SE = 0.000.
BALL DIAMETER
eE
0.80 BSC
BALL PITCH
eD
0.80 BSC
BALL PITCH
SD / SE
0.40 BSC
SOLDER BALL PLACEMENT
A2,A3,A4,A5,A6,A7,A8,A9
DEPOPULATED SOLDER BALLS
B1,B10,C1,C10,D1,D10
E1,E10,F1,F10,G1,G10
H1,H10,J1,J10,K1,K10,L1,L10
M2,M3,M4,M5,M6,M7,M8,M9
WHEN THERE IS AN EVEN NUMBER OF SOLDER BALLS IN THE
OUTER ROW, SD OR SE = e/2
8.
"+" INDICATES THE THEORETICAL CENTER OF DEPOPULATED
BALLS.
9.
N/A
10 A1 CORNER TO BE IDENTIFIED BY CHAMFER, LASER OR INK
MARK, METALLIZED MARK INDENTATION OR OTHER MEANS.
3439 \ 16-038.22 \ 01.04.05
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
13
S29WS-N MirrorBit™ Flash Family
S29WS256N, S29WS128N, S29WS064N
256/128/64 Megabit (16/8/4 M x 16-Bit) CMOS 1.8 Volt-only
Simultaneous Read/Write, Burst Mode Flash Memory
ADVANCE
INFORMATION
Data Sheet
General Description
The Spansion S29WS256/128/064N are Mirrorbit™ Flash products fabricated on 110 nm process technology. These burst
mode Flash devices are capable of performing simultaneous read and write operations with zero latency on two separate
banks using separate data and address pins. These products can operate up to 80 MHz and use a single VCC of
1.7 V to 1.95 V that makes them ideal for today’s demanding wireless applications requiring higher density, better performance and lowered power consumption.
Distinctive Characteristics
„
„
„
„
„
„
„
„
„
„
„
„
„
Single 1.8 V read/program/erase (1.70–1.95 V)
110 nm MirrorBit™ Technology
Simultaneous Read/Write operation with zero
latency
32-word Write Buffer
Sixteen-bank architecture consisting of 16/8/4
Mwords for WS256N/128N/064N, respectively
Four 16 Kword sectors at both top and bottom of
memory array
254/126/62 64 Kword sectors (WS256N/128N/
064N)
Programmable burst read modes
— Linear for 32, 16 or 8 words linear read with or
without wrap-around
— Continuous sequential read mode
Secured Silicon Sector region consisting of 128
words each for factory and customer
20-year data retention (typical)
Cycling Endurance: 100,000 cycles per sector
(typical)
RDY output indicates data available to system
Command set compatible with JEDEC (42.4)
standard
„
Hardware (WP#) protection of top and bottom
sectors
„
Dual boot sector configuration (top and bottom)
„
Offered Packages
— WS064N: 80-ball FBGA (7 mm x 9 mm)
— WS256N/128N: 84-ball FBGA (8 mm x 11.6 mm)
„
„
Low VCC write inhibit
Persistent and Password methods of Advanced
Sector Protection
Write operation status bits indicate program and
erase operation completion
„
„
„
„
„
„
„
Suspend and Resume commands for Program and
Erase operations
Unlock Bypass program command to reduce
programming time
Synchronous or Asynchronous program operation,
independent of burst control register settings
ACC input pin to reduce factory programming time
Support for Common Flash Interface (CFI)
Industrial Temperature range (contact factory)
Performance Characteristics
Read Access Times
Current Consumption (typical values)
Speed Option (MHz)
80
Max. Synch. Latency, ns (tIACC)
66
54
Continuous Burst Read @ 66 MHz
35 mA
Simultaneous Operation (asynchronous)
50 mA
Program (asynchronous)
19 mA
80
80
80
Max. Synch. Burst Access, ns (tBACC)
9
11.2
13.5
Max. Asynch. Access Time, ns (tACC)
80
80
80
Erase (asynchronous)
19 mA
Standby Mode (asynchronous)
20 µA
Max CE# Access Time, ns (tCE)
80
80
80
Max OE# Access Time, ns (tOE)
13.5
13.5
13.5
Typical Program & Erase Times
Publication Number S70WS512N00_00
Single Word Programming
40 µs
Effective Write Buffer Programming (VCC) Per Word
9.4 µs
Effective Write Buffer Programming (VACC) Per Word
6 µs
Sector Erase (16 Kword Sector)
150 ms
Sector Erase (64 Kword Sector)
600 ms
Revision A
Amendment 0
Issue Date March 14, 2005
A d v a n c e
6
I n f o r m a t i o n
Additional Resources
Visit www.amd.com and www.fujitsu.com to obtain the following related documents:
Application Notes
„ Using the Operation Status Bits in AMD Devices
„ Understanding Burst Mode Flash Memory Devices
„ Simultaneous Read/Write vs. Erase Suspend/Resume
„ MirrorBit™ Flash Memory Write Buffer Programming and Page Buffer Read
„ Design-In Scalable Wireless Solutions with Spansion Products
„ Common Flash Interface Version 1.4 Vendor Specific Extensions
Specification Bulletins
Contact your local sales office for details.
Drivers and Software Support
„ Spansion low-level drivers
„ Enhanced Flash drivers
„ Flash file system
CAD Modeling Support
„ VHDL and Verilog
„ IBIS
„ ORCAD
Technical Support
Contact your local sales office or contact Spansion LLC directly for additional technical support:
Email
US and Canada: [email protected]
Asia Pacific: [email protected]
Europe, Middle East, and Africa
Japan: http://edevice.fujitsu.com/jp/support/tech/#b7
Frequently Asked Questions (FAQ)
http://ask.amd.com/
http://edevice.fujitsu.com/jp/support/tech/#b7
Phone
US: (408) 749-5703
Japan (03) 5322-3324
Spansion LLC Locations
915 DeGuigne Drive, P.O. Box 3453
Sunnyvale, CA 94088-3453, USA
Telephone: 408-962-2500 or
1-866-SPANSION
Spansion Japan Limited
4-33-4 Nishi Shinjuku, Shinjuku-ku
Tokyo, 160-0023
Telephone: +81-3-5302-2200
Facsimile: +81-3-5302-2674
http://www.spansion.com
18
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
7
I n f o r m a t i o n
Product Overview
The S29WS-N family consists of 256, 128 and 64Mbit, 1.8 volts-only, simultaneous read/write
burst mode Flash device optimized for today’s wireless designs that demand a large storage array,
rich functionality, and low power consumption.
These devices are organized in 16, 8 or 4 Mwords of 16 bits each and are capable of continuous,
synchronous (burst) read or linear read (8-, 16-, or 32-word aligned group) with or without wrap
around. These products also offer single word programming or a 32-word buffer for programming
with program/erase and suspend functionality. Additional features include:
„ Advanced Sector Protection methods for protecting sectors as required
„ 256 words of Secured Silicon area for storing customer and factory secured information. The
Secured Silicon Sector is One Time Programmable.
7.1
Memory Map
The S29WS256/128/064N Mbit devices consist of 16 banks organized as shown in Tables
Table 7.1, Table 7.2, and Table 7.3.
Table 7.1 S29WS256N Sector & Memory Address Map
Bank
Size
Sector
Count
Sector Size
(KB)
4
32
15
128
2 MB
16
128
2 MB
16
2 MB
16
2 MB
2 MB
Bank
0
Sector/
Sector Range
Address Range
SA000
000000h–003FFFh
SA001
004000h–007FFFh
SA002
008000h–00BFFFh
SA003
00C000h–00FFFFh
SA004 to SA018
010000h–01FFFFh to 0F0000h–0FFFFFh
1
SA019 to SA034
100000h–10FFFFh to 1F0000h–1FFFFFh
128
2
SA035 to SA050
200000h–20FFFFh to 2F0000h–2FFFFFh
128
3
SA051 to SA066
300000h–30FFFFh to 3F0000h–3FFFFFh
16
128
4
SA067 to SA082
400000h–40FFFFh to 4F0000h–4FFFFFh
2 MB
16
128
5
SA083 to SA098
500000h–50FFFFh to 5F0000h–5FFFFFh
2 MB
16
128
6
SA099 to SA114
600000h–60FFFFh to 6F0000h–6FFFFFh
2 MB
16
128
7
SA115 to SA130
700000h–70FFFFh to 7F0000h–7FFFFFh
2 MB
16
128
8
SA131 to SA146
800000h–80FFFFh to 8F0000h–8FFFFFh
2 MB
16
128
9
SA147 to SA162
900000h–90FFFFh to 9F0000h–9FFFFFh
2 MB
16
128
10
SA163 to SA178
A00000h–A0FFFFh to AF0000h–AFFFFFh
2 MB
16
128
11
SA179 to SA194
B00000h–B0FFFFh to BF0000h–BFFFFFh
2 MB
16
128
12
SA195 to SA210
C00000h–C0FFFFh to CF0000h–CFFFFFh
2 MB
16
128
13
SA211 to SA226
D00000h–D0FFFFh to DF0000h–DFFFFFh
2 MB
16
128
14
15
128
2 MB
4
32
15
SA227 to SA242
E00000h–E0FFFFh to EF0000h–EFFFFFh
SA243 to SA257
F00000h–F0FFFFh to FE0000h–FEFFFFh
SA258
FF0000h–FF3FFFh
SA259
FF4000h–FF7FFFh
SA260
FF8000h–FFBFFFh
SA261
FFC000h–FFFFFFh
Notes
Contains four smaller sectors at
bottom of addressable memory.
All 128 KB sectors.
Pattern for sector address
range is xx0000h–xxFFFFh.
(see note)
Contains four smaller sectors
at top of addressable memory.
Note: This table has been condensed to show sector-related information for an entire device on a single page.
Sectors and their address ranges that are not explicitly listed (such as SA005–SA017) have sector
starting and ending addresses that form the same pattern as all other sectors of that size. For example,
all 128 KB sectors have the pattern xx00000h–xxFFFFh.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
19
A d v a n c e
Table 7.2
Bank
Size
1 MB
Sector
Count
4
Sector Size
(KB)
I n f o r m a t i o n
S29WS128N Sector & Memory Address Map
Sector/
Sector Range
Address Range
32
SA000
000000h–003FFFh
32
SA001
004000h–007FFFh
SA002
008000h–00BFFFh
32
Bank
0
32
SA003
00C000h–00FFFFh
7
128
SA004 to SA010
010000h–01FFFFh to 070000h–07FFFFh
1 MB
8
128
1
SA011 to SA018
080000h–08FFFFh to 0F0000h–0FFFFFh
1 MB
8
128
2
SA019 to SA026
100000h–10FFFFh to 170000h–17FFFFh
1 MB
8
128
3
SA027 to SA034
180000h–18FFFFh to 1F0000h–1FFFFFh
1 MB
8
128
4
SA035 to SA042
200000h–20FFFFh to 270000h–27FFFFh
1 MB
8
128
5
SA043 to SA050
280000h–28FFFFh to 2F0000h–2FFFFFh
1 MB
8
128
6
SA051 to SA058
300000h–30FFFFh to 370000h–37FFFFh
1 MB
8
128
7
SA059 to SA066
380000h–38FFFFh to 3F0000h–3FFFFFh
1 MB
8
128
8
SA067 to SA074
400000h–40FFFFh to 470000h–47FFFFh
1 MB
8
128
9
SA075 to SA082
480000h–48FFFFh to 4F0000h–4FFFFFh
1 MB
8
128
10
SA083 to SA090
500000h–50FFFFh to 570000h–57FFFFh
1 MB
8
128
11
SA091 to SA098
580000h–58FFFFh to 5F0000h–5FFFFFh
1 MB
8
128
12
SA099 to SA106
600000h–60FFFFh to 670000h–67FFFFh
1 MB
8
128
13
SA107 to SA114
680000h–68FFFFh to 6F0000h–6FFFFFh
1 MB
8
128
14
SA115 to SA122
700000h–70FFFFh to 770000h–77FFFFh
7
128
SA123 to SA129
780000h–78FFFFh to 7E0000h–7EFFFFh
32
SA130
7F0000h–7F3FFFh
SA131
7F4000h–7F7FFFh
32
SA132
7F8000h–7FBFFFh
32
SA133
7FC000h–7FFFFFh
1 MB
4
32
15
Notes
Contains four smaller sectors at
bottom of addressable memory.
All 128 KB sectors.
Pattern for sector
address range is
xx0000h–xxFFFFh.
(See Note)
Contains four smaller sectors
at top of addressable memory.
Note: This table has been condensed to show sector-related information for an entire device on a single page.
Sectors and their address ranges that are not explicitly listed (such as SA005–SA009) have sector
starting and ending addresses that form the same pattern as all other sectors of that size. For example,
all 128 KB sectors have the pattern xx00000h–xxFFFFh.
20
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Table 7.3
Bank
Size
Sector
Count
4
Sector Size
(KB)
Bank
32
0
0.5 MB
3
128
S29WS064N Sector & Memory Address Map
Sector/
Sector Range
Address Range
SA000
000000h–003FFFh
SA001
004000h–007FFFh
SA002
008000h–00BFFFh
SA003
00C000h–00FFFFh
SA004
010000h–01FFFFh
SA005
020000h–02FFFFh
SA006
030000h–03FFFFh
0.5 MB
4
128
1
SA007–SA010
040000h–04FFFFh to 070000h–07FFFFh
0.5 MB
4
128
2
SA011–SA014
080000h–08FFFFh to 0B0000h–0BFFFFh
0.5 MB
4
128
3
SA015–SA018
0C0000h–0CFFFFh to 0F0000h–0FFFFFh
0.5 MB
4
128
4
SA019–SA022
100000h–10FFFFh to 130000h–13FFFFh
0.5 MB
4
128
5
SA023–SA026
140000h–14FFFFh to 170000h–17FFFFh
0.5 MB
4
128
6
SA027–SA030
180000h–18FFFFh to 1B0000h–1BFFFFh
0.5 MB
4
128
7
SA031–SA034
1C0000h–1CFFFFh to 1F0000h–1FFFFFh
0.5 MB
4
128
8
SA035–SA038
200000h–20FFFFh to 230000h–23FFFFh
0.5 MB
4
128
9
SA039–SA042
240000h–24FFFFh to 270000h–27FFFFh
0.5 MB
4
128
10
SA043–SA046
280000h–28FFFFh to 2B0000h–2BFFFFh
0.5 MB
4
128
11
SA047–SA050
2C0000h–2CFFFFh to 2F0000h–2FFFFFh
0.5 MB
4
128
12
SA051–SA054
300000h–30FFFFh to 330000h–33FFFFh
0.5 MB
4
128
13
SA055–SA058
340000h–34FFFFh to 370000h–37FFFFh
0.5 MB
4
128
14
SA059–SA062
380000h–38FFFFh to 3B0000h–3BFFFFh
3
128
0.5 MB
15
4
32
SA063
3C0000h–3CFFFFh
SA064
3D0000h–3DFFFFh
SA065
3E0000h–3EFFFFh
SA066
3F0000h–3F3FFFh
SA067
3F4000h–3F7FFFh
SA068
3F8000h–3FBFFFh
SA069
3FC000h–3FFFFFh
Notes
Contains four smaller sectors
at bottom of addressable memory.
All 128 KB sectors.
Pattern for sector
address range is
xx0000h–xxFFFFh.
(see note)
Contains four smaller sectors a
t top of addressable memory.
Note: This table has been condensed to show sector-related information for an entire device on a single page.
Sectors and their address ranges that are not explicitly listed (such as SA008–SA009) have sector
starting and ending addresses that form the same pattern as all other sectors of that size. For example,
all 128 KB sectors have the pattern xx00000h–xxFFFFh.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
21
A d v a n c e
8
I n f o r m a t i o n
Device Operations
This section describes the read, program, erase, simultaneous read/write operations, handshaking, and reset features of the Flash devices.
Operations are initiated by writing specific commands or a sequence with specific address and
data patterns into the command registers (see Table 13.1 and Table 13.2). The command register itself does not occupy any addressable memory location; rather, it is composed of latches that
store the commands, along with the address and data information needed to execute the command. The contents of the register serve as input to the internal state machine and the state
machine outputs dictate the function of the device. Writing incorrect address and data values or
writing them in an improper sequence may place the device in an unknown state, in which case
the system must write the reset command to return the device to the reading array data mode.
8.1
Device Operation Table
The device must be setup appropriately for each operation. Table 8.1 describes the required state
of each control pin for any particular operation.
Table 8.1
Operation
Device Operations
CE#
OE#
WE#
Addresses
DQ15–0
RESET#
CLK
AVD#
Asynchronous Read - Addresses Latched
L
L
H
Addr In
Data Out
H
X
Asynchronous Read - Addresses Steady State
L
L
H
Addr In
Data Out
H
X
L
Asynchronous Write
L
H
L
Addr In
I/O
H
X
L
Synchronous Write
L
H
L
Addr In
I/O
H
Standby (CE#)
H
X
X
X
HIGH Z
H
X
X
Hardware Reset
X
X
X
X
HIGH Z
L
X
X
Load Starting Burst Address
L
X
H
Addr In
X
H
Advance Burst to next address with appropriate Data
presented on the Data Bus
L
L
H
X
Burst
Data Out
H
H
Terminate current Burst read cycle
H
X
H
X
HIGH Z
H
X
Terminate current Burst read cycle via RESET#
X
X
H
X
HIGH Z
L
Terminate current Burst read cycle and start new Burst
read cycle
L
X
H
Addr In
I/O
H
Burst Read Operations (Synchronous)
X
X
Legend: L = Logic 0, H = Logic 1, X = Don’t Care, I/O = Input/Output.
8.2
Asynchronous Read
All memories require access time to output array data. In an asynchronous read operation, data
is read from one memory location at a time. Addresses are presented to the device in random
order, and the propagation delay through the device causes the data on its outputs to arrive asynchronously with the address on its inputs.
The device defaults to reading array data asynchronously after device power-up or hardware reset. Asynchronous read requires that the CLK signal remain at VIL during the entire memory read
operation. To read data from the memory array, the system must first assert a valid address on
Amax–A0, while driving AVD# and CE# to VIL. WE# must remain at VIH. The rising edge of AVD#
latches the address. The OE# signal must be driven to VIL, once AVD# has been driven to VIH.
Data is output on A/DQ15-A/DQ0 pins after the access time (tOE) has elapsed from the falling
edge of OE#.
22
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
8.3
I n f o r m a t i o n
Synchronous (Burst) Read Mode and Configuration Register
When a series of adjacent addresses needs to be read from the device (in order from lowest to
highest address), the synchronous (or burst read) mode can be used to significantly reduce the
overall time needed for the device to output array data. After an initial access time required for
the data from the first address location, subsequent data is output synchronized to a clock input
provided by the system.
The device offers both continuous and linear methods of burst read operation, which are discussed in sections 8.3.1, 8.3.2, and 8.3.3.
Since the device defaults to asynchronous read mode after power-up or a hardware reset, the
configuration register must be set to enable the burst read mode. Other Configuration Register
settings include the number of wait states to insert before the initial word (tIACC) of each burst
access, the burst mode in which to operate, and when RDY indicates data is ready to be read.
Prior to entering the burst mode, the system should first determine the configuration register settings (and read the current register settings if desired via the Read Configuration Register
command sequence), and then write the configuration register command sequence. See 8.3.4
and Table 13.1 for further details.
Power-up/
Hardware Reset
Asynchronous Read
Mode Only
Set Burst Mode
Configuration Register
Command for
Synchronous Mode
(CR15 = 0)
Set Burst Mode
Configuration Register
Command for
Asynchronous Mode
(CR15 = 1)
Synchronous Read
Mode Only
Figure 8.1
Synchronous/Asynchronous State Diagram
The device outputs the initial word subject to the following operational conditions:
„ tIACC specification: the time from the rising edge of the first clock cycle after addresses are
latched to valid data on the device outputs.
„ Configuration register setting CR13–CR11: the total number of clock cycles (wait states)
that occur before valid data appears on the device outputs. The effect is that tIACC is
lengthened.
The device outputs subsequent words tBACC after the active edge of each successive clock cycle,
which also increments the internal address counter. The device outputs burst data at this rate subject to the following operational conditions:
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
23
A d v a n c e
I n f o r m a t i o n
„ Starting address: whether the address is divisible by four (where A[1:0] is 00). A divisibleby-four address incurs the least number of additional wait states that occur after the initial
word. The number of additional wait states required increases for burst operations in which
the starting address is one, two, or three locations above the divisible-by-four address (i.e.,
where A[1:0] is 01, 10, or 11).
„ Boundary crossing: There is a boundary at every 128 words due to the internal architecture
of the device. One additional wait state must be inserted when crossing this boundary if the
memory bus is operating at a high clock frequency. Please refer to the tables below.
„ Clock frequency: the speed at which the device is expected to burst data. Higher speeds
require additional wait states after the initial word for proper operation.
In all cases, with or without latency, the RDY output indicates when the next data is available to
be read.
Tables 8.2 – 8.6 reflect wait states required for S29WS256/128/064N devices. Refer to the Configuration Register table (CR11 – CR14) and timing diagrams for more details.
Table 8.2
Word
Wait States
Cycle
0
x ws
D0
D1
D2
D3
D4
D5
D6
D7
D8
1
x ws
D1
D2
D3
1 ws
D4
D5
D6
D7
D8
2
x ws
D2
D3
1 ws
1 ws
D4
D5
D6
D7
D8
3
x ws
D3
1 ws
1 ws
1 ws
D4
D5
D6
D7
D8
Table 8.3
Address Latency (S29WS128N/S29WS064N)
Word
Wait States
0
5, 6, 7 ws
D0
D1
D2
D3
D4
D5
D6
D7
D8
1
5, 6, 7 ws
D1
D2
D3
1 ws
D4
D5
D6
D7
D8
2
5, 6, 7 ws
D2
D3
1 ws
1 ws
D4
D5
D6
D7
D8
3
5, 6, 7 ws
D3
1 ws
1 ws
1 ws
D4
D5
D6
D7
D8
Table 8.4
24
Address Latency (S29WS256N)
Cycle
Address/Boundary Crossing Latency (S29WS256N @ 80/66 MHz)
Word
Wait States
Cycle
0
7, 6 ws
D0
D1
D2
D3
1 ws
D4
D5
D6
D7
1
7, 6 ws
D1
D2
D3
1 ws
1 ws
D4
D5
D6
D7
2
7, 6 ws
D2
D3
1 ws
1 ws
1 ws
D4
D5
D6
D7
3
7, 6 ws
D3
1 ws
1 ws
1 ws
1 ws
D4
D5
D6
D7
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
Table 8.5
I n f o r m a t i o n
Address/Boundary Crossing Latency (S29WS256N @ 54MHz)
Word
Wait States
0
5 ws
D0
D1
D2
D3
D4
D5
D6
D7
D8
1
5 ws
D1
D2
D3
1 ws
D4
D5
D6
D7
D8
2
5 ws
D2
D3
1 ws
1 ws
D4
D5
D6
D7
D8
3
5 ws
D3
1 ws
1 ws
1 ws
D4
D5
D6
D7
D8
Table 8.6
Cycle
Address/Boundary Crossing Latency (S29WS128N/S29WS064N)
Word
Wait States
0
5, 6, 7 ws
D0
D1
D2
D3
1 ws
D4
D5
D6
D7
1
5, 6, 7 ws
D1
D2
D3
1 ws
1 ws
D4
D5
D6
D7
2
5, 6, 7 ws
D2
D3
1 ws
1 ws
1 ws
D4
D5
D6
D7
3
5, 6, 7 ws
D3
1 ws
1 ws
1 ws
1 ws
D4
D5
D6
D7
March 14, 2005 S70WS512N00_00_A0
Cycle
S70WS512N00 Based MCPs
25
A d v a n c e
I n f o r m a t i o n
Note: Setup Configuration Register parameters
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Write Set Configuration Register
Command and Settings:
Address 555h, Data D0h
Address X00h, Data CR
Load Initial Address
Address = RA
Wait tIACC +
Programmable Wait State Setting
Read Initial Data
RD = DQ[15:0]
Unlock Cycle 1
Unlock Cycle 2
Command Cycle
CR = Configuration Register Bits CR15-CR0
RA = Read Address
CR13-CR11 sets initial access time
(from address latched to
valid data) from 2 to 7 clock cycles
RD = Read Data
Wait X Clocks:
Additional Latency Due to Starting
Address, Clock Frequency, and
Boundary Crossing
Read Next Data
RD = DQ[15:0]
Delay X Clocks
Yes
Crossing
Boundary?
No
End of Data?
Yes
Completed
Figure 8.2 Synchronous Read
8.3.1
Continuous Burst Read Mode
In the continuous burst read mode, the device outputs sequential burst data from the starting
address given and then wrap around to address 000000h when it reaches the highest addressable
memory location. The burst read mode continues until the system drives CE# high, or RESET=
VIL. Continuous burst mode can also be aborted by asserting AVD# low and providing a new address to the device.
If the address being read crosses a 128-word line boundary (as mentioned above) and the subsequent word line is not being programmed or erased, additional latency cycles are required as
reflected by the configuration register table (Table 8.8).
If the address crosses a bank boundary while the subsequent bank is programming or erasing,
the device provides read status information and the clock is ignored. Upon completion of status
read or program or erase operation, the host can restart a burst read operation using a new address and AVD# pulse.
26
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
8.3.2
I n f o r m a t i o n
8-, 16-, 32-Word Linear Burst Read with Wrap Around
In a linear burst read operation, a fixed number of words (8, 16, or 32 words) are read from consecutive addresses that are determined by the group within which the starting address falls. The
groups are sized according to the number of words read in a single burst sequence for a given
mode (see Table 8.7).
For example, if the starting address in the 8-word mode is 3Ch, the address range to be read
would be 38-3Fh, and the burst sequence would be 3C-3D-3E-3F-38-39-3A-3Bh. Thus, the device
outputs all words in that burst address group until all word are read, regardless of where the starting address occurs in the address group, and then terminates the burst read.
In a similar fashion, the 16-word and 32-word Linear Wrap modes begin their burst sequence on
the starting address provided to the device, then wrap back to the first address in the selected
address group.
Note that in this mode the address pointer does not cross the boundary that occurs every 128
words; thus, no additional wait states are inserted due to boundary crossing.
Table 8.7
8.3.3
Burst Address Groups
Mode
Group Size
Group Address Ranges
8-word
8 words
0-7h, 8-Fh, 10-17h,...
16-word
16 words
0-Fh, 10-1Fh, 20-2Fh,...
32-word
32 words
00-1Fh, 20-3Fh, 40-5Fh,...
8-, 16-, 32-Word Linear Burst without Wrap Around
If wrap around is not enabled for linear burst read operations, the 8-word, 16-word, or 32-word
burst executes up to the maximum memory address of the selected number of words. The burst
stops after 8, 16, or 32 addresses and does not wrap around to the first address of the selected
group.
For example, if the starting address in the 8- word mode is 3Ch, the address range to be read
would be 39-40h, and the burst sequence would be 3C-3D-3E-3F-40-41-42-43h if wrap around
is not enabled. The next address to be read requires a new address and AVD# pulse. Note that
in this burst read mode, the address pointer may cross the boundary that occurs every 128 words,
which will incur the additional boundary crossing wait state.
8.3.4
Configuration Register
The configuration register sets various operational parameters associated with burst mode. Upon
power-up or hardware reset, the device defaults to the asynchronous read mode, and the configuration register settings are in their default state. The host system should determine the proper
settings for the entire configuration register, and then execute the Set Configuration Register
command sequence, before attempting burst operations. The configuration register is not reset
after deasserting CE#. The Configuration Register can also be read using a command sequence
(see Table 13.1). The following list describes the register settings.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
27
A d v a n c e
Table 8.8
CR Bit
CR15
I n f o r m a t i o n
Configuration Register
Function
Settings (Binary)
Set Device Read
Mode
0 = Synchronous Read (Burst Mode) Enabled
1 = Asynchronous Read Mode (default) Enabled
54 MHz 66 Mhz 80 MHz
CR14
Boundary Crossing
CR13
S29WS064N
S29WS128N
N/A
N/A
N/A
S29WS256N
0
1
1
S29WS064N
S29WS128N
0
1
1
1
0
0
1
0
1
S29WS256N
Programmable
Wait State
CR12
S29WS064N
S29WS128N
S29WS256N
S29WS064N
S29WS128N
CR11
S29WS256N
CR10
Default value is 0
0 = No extra boundary crossing latency
1 = With extra boundary crossing latency (default)
Must be set to 1 greater than 54 MHz.
011 = Data valid on 5th active CLK
edge after addresses latched
100 = Data valid on 6th active CLK
edge after addresses latched
101 = Data valid on 7th active CLK
edge after addresses latched (default)
110 = Reserved
111 = Reserved
Inserts wait states before initial data
is available. Setting greater number of wait
states before initial data reduces latency
after initial data. (Notes 1, 2)
0 = RDY signal active low
1 = RDY signal active high (default)
RDY Polarity
CR9
Reserved
CR8
RDY
CR7
Reserved
1 = default
CR6
Reserved
1 = default
CR5
Reserved
0 = default
CR4
Reserved
0 = default
CR3
Burst Wrap Around
CR2
CR1
CR0
1 = default
0 = RDY active one clock cycle before data
1 = RDY active with data (default)
When CR13-CR11 are set to 000,
RDY is active with data regardless of CR8 setting.
0 = No Wrap Around Burst
1 = Wrap Around Burst (default)
000 = Continuous (default)
010 = 8-Word Linear Burst
011 = 16-Word Linear Burst
100 = 32-Word Linear Burst
(All other bit settings are reserved)
Burst Length
Notes:
1.
2.
Refer to Tables 8.2 - 8.6 for wait states requirements.
Refer to Synchronous Burst Read timing diagrams
3.
Configuration Register is in the default state upon power-up or hardware reset.
Reading the Configuration Table. The configuration register can be read with a four-cycle command sequence. See Table 13.1 for sequence details. Once the data has been read from the
configuration register, a software reset command is required to set the device into the correct
state.
8.4
Autoselect
The Autoselect is used for manufacturer ID, Device identification, and sector protection information. This mode is primarily intended for programming equipment to automatically match a device
with its corresponding programming algorithm. The Autoselect codes can also be accessed in-system. When verifying sector protection, the sector address must appear on the appropriate highest
order address bits (see Table 8.9). The remaining address bits are don't care. The most significant
four bits of the address during the third write cycle selects the bank from which the Autoselect
codes are read by the host. All other banks can be accessed normally for data read without exiting
the Autoselect mode.
„ To access the Autoselect codes, the host system must issue the Autoselect command.
28
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
„ The Autoselect command sequence may be written to an address within a bank that is either
in the read or erase-suspend-read mode.
„ The Autoselect command may not be written while the device is actively programming or
erasing. Autoselect does not support simultaneous operations or burst mode.
„ The system must write the reset command to return to the read mode (or erase-suspendread mode if the bank was previously in Erase Suspend).
See Table 13.1 for command sequence details.
Table 8.9
Description
Autoselect Addresses
Address
Read Data
Manufacturer ID
(BA) + 00h
0001h
Device ID, Word 1
(BA) + 01h
227Eh
Device ID, Word 2
(BA) + 0Eh
2230 (WS256N)
2231 (WS128N)
2232 (WS064N)
Device ID, Word 3
(BA) + 0Fh
2200
DQ15 - DQ8 = Reserved
DQ7 (Factory Lock Bit): 1 = Locked, 0 = Not Locked
DQ6 (Customer Lock Bit): 1 = Locked, 0 = Not Locked
DQ5 (Handshake Bit): 1 = Reserved, 0 = Standard Handshake
Indicator Bits
(See Note)
(BA) + 03h
DQ4, DQ3 (WP# Protection Boot Code): 00 = WP# Protects both Top Boot and
Bottom Boot Sectors. 01, 10, 11 = Reserved
DQ2 = Reserved
DQ1 (DYB Power up State [Lock Register DQ4]): 1 = Unlocked (user option),
0 = Locked (default)
DQ0 (PPB Eraseability [Lock Register DQ3]): 1 = Erase allowed,
0 = Erase disabled
Sector Block Lock/
Unlock
(SA) + 02h
0001h = Locked, 0000h = Unlocked
Note: For WS128N and WS064, DQ1 and DQ0 are reserved.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
29
A d v a n c e
I n f o r m a t i o n
Software Functions and Sample Code
Table 8.10
Autoselect Entry
(LLD Function = lld_AutoselectEntryCmd)
Cycle
Operation
Byte Address
Word Address
Data
Unlock Cycle 1
Write
BAxAAAh
BAx555h
0x00AAh
Unlock Cycle 2
Write
BAx555h
BAx2AAh
0x0055h
Autoselect Command
Write
BAxAAAh
BAx555h
0x0090h
Table 8.11
Autoselect Exit
(LLD Function = lld_AutoselectExitCmd)
Cycle
Operation
Byte Address
Word Address
Data
Unlock Cycle 1
Write
base + XXXh
base + XXXh
0x00F0h
Notes:
1. Any offset within the device works.
2. BA = Bank Address. The bank address is required.
3. base = base address.
The following is a C source code example of using the autoselect function to read the manufacturer ID. Refer to the Spansion Low Level Driver User Guide (available on www.amd.com
and www.fujitsu.com) for general information on Spansion Flash memory software development guidelines.
/* Here is an example of Autoselect mode (getting manufacturer ID) */
/* Define UINT16 example: typedef unsigned short UINT16; */
UINT16 manuf_id;
/* Auto Select Entry */
*( (UINT16 *)bank_addr + 0x555 ) = 0x00AA; /* write unlock cycle 1 */
*( (UINT16 *)bank_addr + 0x2AA ) = 0x0055; /* write unlock cycle 2 */
*( (UINT16 *)bank_addr + 0x555 ) = 0x0090; /* write autoselect command */
/* multiple reads can be performed after entry */
manuf_id = *( (UINT16 *)bank_addr + 0x000 ); /* read manuf. id */
/*
Autoselect exit */
*( (UINT16 *)base_addr + 0x000 ) = 0x00F0; /* exit autoselect (write reset command) */
30
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
8.5
I n f o r m a t i o n
Program/Erase Operations
These devices are capable of several modes of programming and or erase operations which are
described in detail in the following sections. However, prior to any programming and or erase operation, devices must be setup appropriately as outlined in the configuration register (Table 8.8).
For any program and or erase operations, including writing command sequences, the system
must drive AVD# and CE# to VIL, and OE# to VIH when providing an address to the device, and
drive WE# and CE# to VIL, and OE# to VIH when writing commands or programming data.
Addresses are latched on the last falling edge of WE# or CE#, while data is latched on the 1st
rising edge of WE# or CE#.
Note the following:
„ When the Embedded Program algorithm is complete, the device returns to the read mode.
„ The system can determine the status of the program operation by using DQ7 or DQ6. Refer
to the Write Operation Status section for information on these status bits.
„ A 0 cannot be programmed back to a 1. Attempting to do so causes the device to set DQ5 = 1
(halting any further operation and requiring a reset command). A succeeding read shows that
the data is still 0. Only erase operations can convert a 0 to a 1.
„ Any commands written to the device during the Embedded Program Algorithm are ignored
except the Program Suspend command.
„ Secured Silicon Sector, Autoselect, and CFI functions are unavailable when a program operation is in progress.
„ A hardware reset immediately terminates the program operation and the program command
sequence should be reinitiated once the device has returned to the read mode, to ensure data
integrity.
„ Programming is allowed in any sequence and across sector boundaries for single word programming operation.
8.5.1
Single Word Programming
Single word programming mode is the simplest method of programming. In this mode, four Flash
command write cycles are used to program an individual Flash address. The data for this programming operation could be 8-, 16- or 32-bits wide. While this method is supported by all
Spansion devices, in general it is not recommended for devices that support Write Buffer Programming. See Table 13.1 for the required bus cycles and Figure 8.3 for the flowchart.
When the Embedded Program algorithm is complete, the device then returns to the read mode
and addresses are no longer latched. The system can determine the status of the program operation by using DQ7 or DQ6. Refer to the Write Operation Status section for information on these
status bits.
„ During programming, any command (except the Suspend Program command) is ignored.
„ The Secured Silicon Sector, Autoselect, and CFI functions are unavailable when a program operation is in progress.
„ A hardware reset immediately terminates the program operation. The program command sequence should be reinitiated once the device has returned to the read mode, to ensure data
integrity.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
31
A d v a n c e
I n f o r m a t i o n
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Unlock Cycle 1
Unlock Cycle 2
Write Program Command:
Address 555h, Data A0h
Setup Command
Program Address (PA),
Program Data (PD)
Program Data to Address:
PA, PD
Perform Polling Algorithm
(see Write Operation Status
flowchart)
Polling Status
= Busy?
Yes
No
Yes
Polling Status
= Done?
Error condition
(Exceeded Timing Limits)
No
PASS. Device is in
read mode.
Figure 8.3
32
FAIL. Issue reset command
to return to read array mode.
Single Word Program
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Software Functions and Sample Code
Table 8.12
Single Word Program
(LLD Function = lld_ProgramCmd)
Cycle
Operation
Byte Address
Word Address
Data
Unlock Cycle 1
Write
Base + AAAh
Base + 555h
00AAh
Unlock Cycle 2
Write
Base + 554h
Base + 2AAh
0055h
Program Setup
Write
Base + AAAh
Base + 555h
00A0h
Program
Write
Word Address
Word Address
Data Word
Note: Base = Base Address.
The following is a C source code example of using the single word program function. Refer to
the Spansion Low Level Driver User’s Guide (available on www.amd.com and
www.fujitsu.com) for general information on Spansion Flash memory software development
guidelines.
/* Example: Program Command
*/
*( (UINT16 *)base_addr + 0x555 )
*( (UINT16 *)base_addr + 0x2AA )
*( (UINT16 *)base_addr + 0x555 )
*( (UINT16 *)pa )
/* Poll for program completion */
8.5.2
=
=
=
=
0x00AA;
0x0055;
0x00A0;
data;
/*
/*
/*
/*
write
write
write
write
unlock cycle 1
unlock cycle 2
program setup command
data to be programmed
*/
*/
*/
*/
Write Buffer Programming
Write Buffer Programming allows the system to write a maximum of 32 words in one programming operation. This results in a faster effective word programming time than the standard word
programming algorithms. The Write Buffer Programming command sequence is initiated by first
writing two unlock cycles. This is followed by a third write cycle containing the Write Buffer Load
command written at the Sector Address in which programming occurs. At this point, the system
writes the number of word locations minus 1 that are loaded into the page buffer at the Sector
Address in which programming occurs. This tells the device how many write buffer addresses are
loaded with data and therefore when to expect the Program Buffer to Flash confirm command.
The number of locations to program cannot exceed the size of the write buffer or the operation
aborts. (Number loaded = the number of locations to program minus 1. For example, if the system programs 6 address locations, then 05h should be written to the device.)
The system then writes the starting address/data combination. This starting address is the first
address/data pair to be programmed, and selects the write-buffer-page address. All subsequent
address/data pairs must fall within the elected-write-buffer-page.
The write-buffer-page is selected by using the addresses AMAX - A5.
The write-buffer-page addresses must be the same for all address/data pairs loaded into the write
buffer. (This means Write Buffer Programming cannot be performed across multiple write-bufferpages. This also means that Write Buffer Programming cannot be performed across multiple sectors. If the system attempts to load programming data outside of the selected write-buffer-page,
the operation ABORTs.)
After writing the Starting Address/Data pair, the system then writes the remaining address/data
pairs into the write buffer.
Note that if a Write Buffer address location is loaded multiple times, the address/data pair counter
is decremented for every data load operation. Also, the last data loaded at a location before the
Program Buffer to Flash confirm command is programmed into the device. It is the software's responsibility to comprehend ramifications of loading a write-buffer location more than once. The
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
33
A d v a n c e
I n f o r m a t i o n
counter decrements for each data load operation, NOT for each unique write-buffer-address location. Once the specified number of write buffer locations have been loaded, the system must then
write the Program Buffer to Flash command at the Sector Address. Any other address/data write
combinations abort the Write Buffer Programming operation. The device goes busy. The Data Bar
polling techniques should be used while monitoring the last address location loaded into the write
buffer. This eliminates the need to store an address in memory because the system can load the
last address location, issue the program confirm command at the last loaded address location,
and then data bar poll at that same address. DQ7, DQ6, DQ5, DQ2, and DQ1 should be monitored
to determine the device status during Write Buffer Programming.
The write-buffer embedded programming operation can be suspended using the standard suspend/resume commands. Upon successful completion of the Write Buffer Programming operation,
the device returns to READ mode.
The Write Buffer Programming Sequence is ABORTED under any of the following conditions:
„ Load a value that is greater than the page buffer size during the Number of Locations to Program step.
„ Write to an address in a sector different than the one specified during the Write-Buffer-Load
command.
„ Write an Address/Data pair to a different write-buffer-page than the one selected by the
Starting Address during the write buffer data loading stage of the operation.
„ Write data other than the Confirm Command after the specified number of data load cycles.
The ABORT condition is indicated by DQ1 = 1, DQ7 = Data# (for the last address location loaded),
DQ6 = TOGGLE, DQ5 = 0. This indicates that the Write Buffer Programming Operation was
ABORTED. A Write-to-Buffer-Abort reset command sequence is required when using the write
buffer Programming features in Unlock Bypass mode. Note that the Secured Silicon sector, autoselect, and CFI functions are unavailable when a program operation is in progress.
Write buffer programming is allowed in any sequence of memory (or address) locations. These
flash devices are capable of handling multiple write buffer programming operations on the same
write buffer address range without intervening erases.
Use of the write buffer is strongly recommended for programming when multiple words are to be
programmed. Write buffer programming is approximately eight times faster than programming
one word at a time.
34
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Software Functions and Sample Code
Table 8.13
Write Buffer Program
(LLD Functions Used = lld_WriteToBufferCmd, lld_ProgramBufferToFlashCmd)
Cycle
Description
Operation
Byte Address
Word Address
Data
1
Unlock
Write
Base + AAAh
Base + 555h
00AAh
2
Unlock
Write
Base + 554h
Base + 2AAh
0055h
3
Write Buffer Load Command
Write
Program Address
0025h
4
Write Word Count
Write
Program Address
Word Count (N–1)h
Number of words (N) loaded into the write buffer can be from 1 to 32 words.
5 to 36
Load Buffer Word N
Write
Program Address, Word N
Word N
Last
Write Buffer to Flash
Write
Sector Address
0029h
Notes:
1. Base = Base Address.
2. Last = Last cycle of write buffer program operation; depending on number of words written, the total
number of cycles may be from 6 to 37.
3. For maximum efficiency, it is recommended that the write buffer be loaded with
the highest number of words (N words) possible.
The following is a C source code example of using the write buffer program function. Refer to
th e S p a n s i o n L o w L e v el D r i v e r U s e r G u i de ( ava il able o n w w w. a m d. c o m a n d
www.fujitsu.comm) for general information on Spansion Flash memory software development guidelines.
/* Example: Write Buffer Programming Command
*/
/* NOTES: Write buffer programming limited to 16 words. */
/*
All addresses to be written to the flash in
*/
/*
one operation must be within the same flash
*/
/*
page. A flash page begins at addresses
*/
/*
evenly divisible by 0x20.
*/
UINT16 *src = source_of_data;
/* address of source data
*/
UINT16 *dst = destination_of_data;
/* flash destination address
*/
UINT16 wc
= words_to_program -1;
/* word count (minus 1)
*/
*( (UINT16 *)base_addr + 0x555 ) = 0x00AA;
/* write unlock cycle 1
*/
*( (UINT16 *)base_addr + 0x2AA ) = 0x0055;
/* write unlock cycle 2
*/
*( (UINT16 *)sector_address )
= 0x0025;
/* write write buffer load command */
*( (UINT16 *)sector_address )
= wc;
/* write word count (minus 1)
*/
loop:
*dst = *src; /* ALL dst MUST BE SAME PAGE */ /* write source data to destination */
dst++;
/* increment destination pointer
*/
src++;
/* increment source pointer
*/
if (wc == 0) goto confirm
/* done when word count equals zero */
wc--;
/* decrement word count
*/
goto loop;
/* do it again
*/
confirm:
*( (UINT16 *)sector_address )
= 0x0029;
/* write confirm command
*/
/* poll for completion */
/* Example: Write Buffer Abort Reset */
*( (UINT16 *)addr + 0x555 ) = 0x00AA;
*( (UINT16 *)addr + 0x2AA ) = 0x0055;
*( (UINT16 *)addr + 0x555 ) = 0x00F0;
March 14, 2005 S70WS512N00_00_A0
/* write unlock cycle 1
/* write unlock cycle 2
/* write buffer abort reset
S70WS512N00 Based MCPs
*/
*/
*/
35
A d v a n c e
I n f o r m a t i o n
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Unlock Cycle 1
Unlock Cycle 2
Issue
Write Buffer Load Command:
Address 555h, Data 25h
Load Word Count to Program
Program Data to Address:
SA = wc
wc = number of words – 1
Yes
Confirm command:
SA 29h
wc = 0?
No
Wait 4 µs
Write Next Word,
Decrement wc:
PA data , wc = wc – 1
No
Write Buffer
Abort Desired?
Perform Polling Algorithm
(see Write Operation Status
flowchart)
Yes
Write to a Different
Sector Address to Cause
Write Buffer Abort
Polling Status
= Done?
Yes
No
No
Yes
Error?
Yes
Write Buffer
Abort?
No
RESET. Issue Write Buffer
Abort Reset Command
PASS. Device is in
read mode.
FAIL. Issue reset command
to return to read array mode.
Figure 8.4 Write Buffer Programming Operation
8.5.3
Sector Erase
The sector erase function erases one or more sectors in the memory array. (See Table 13.1 and
Figure 8.5) The device does not require the system to preprogram prior to erase. The Embedded
Erase algorithm automatically programs and verifies the entire memory for an all zero data pattern prior to electrical erase. After a successful sector erase, all locations within the erased sector
contain FFFFh. The system is not required to provide any controls or timings during these
operations.
After the command sequence is written, a sector erase time-out of no less than tSEA occurs. During the time-out period, additional sector addresses and sector erase commands may be written.
Loading the sector erase buffer may be done in any sequence, and the number of sectors may be
from one sector to all sectors. The time between these additional cycles must be less than tSEA.
36
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Any sector erase address and command following the exceeded time-out (tSEA) may or may not
be accepted. Any command other than Sector Erase or Erase Suspend during the time-out period
resets that bank to the read mode. The system can monitor DQ3 to determine if the sector erase
timer has timed out (see DQ3: Sector Erase Timeout State Indicator). The time-out begins from
the rising edge of the final WE# pulse in the command sequence.
When the Embedded Erase algorithm is complete, the bank returns to reading array data and addresses are no longer latched. Note that while the Embedded Erase operation is in progress, the
system can read data from the non-erasing banks. The system can determine the status of the
erase operation by reading DQ7 or DQ6/DQ2 in the erasing bank. See Write Operation Status for
information on these status bits.
Once the sector erase operation has begun, only the Erase Suspend command is valid. All other
commands are ignored. However, note that a hardware reset immediately terminates the erase
operation. If that occurs, the sector erase command sequence should be reinitiated once that
bank has returned to reading array data, to ensure data integrity.
Figure 8.5 illustrates the algorithm for the erase operation. See Erase/Program Timing for parameters and timing diagrams.
Software Functions and Sample Code
Table 8.14
Sector Erase
(LLD Function = lld_SectorEraseCmd)
Cycle
Description
Operation
Byte Address
Word Address
Data
1
Unlock
Write
Base + AAAh
Base + 555h
00AAh
2
Unlock
Write
Base + 554h
Base + 2AAh
0055h
3
Setup Command
Write
Base + AAAh
Base + 555h
0080h
4
Unlock
Write
Base + AAAh
Base + 555h
00AAh
5
Unlock
Write
Base + 554h
Base + 2AAh
0055h
6
Sector Erase Command
Write
Sector Address
Sector Address
0030h
Unlimited additional sectors may be selected for erase; command(s) must be written within tSEA.
The following is a C source code example of using the sector erase function. Refer to the
Spansion Low Level Driver User’s Guide (available on www.amd.com and www.fujitsu.com)
for general information on Spansion Flash memory software development guidelines.
/* Example: Sector Erase Command
*( (UINT16 *)base_addr + 0x555
*( (UINT16 *)base_addr + 0x2AA
*( (UINT16 *)base_addr + 0x555
*( (UINT16 *)base_addr + 0x555
*( (UINT16 *)base_addr + 0x2AA
*( (UINT16 *)sector_address )
March 14, 2005 S70WS512N00_00_A0
*/
) =
) =
) =
) =
) =
=
0x00AA;
0x0055;
0x0080;
0x00AA;
0x0055;
0x0030;
/*
/*
/*
/*
/*
/*
write
write
write
write
write
write
S70WS512N00 Based MCPs
unlock cycle 1
*/
unlock cycle 2
*/
setup command
*/
additional unlock cycle 1 */
additional unlock cycle 2 */
sector erase command
*/
37
A d v a n c e
I n f o r m a t i o n
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Unlock Cycle 1
Unlock Cycle 2
Write Sector Erase Cycles:
Address 555h, Data 80h
Address 555h, Data AAh
Address 2AAh, Data 55h
Sector Address, Data 30h
Command Cycle 1
Command Cycle 2
Command Cycle 3
Specify first sector for erasure
Select
Additional
Sectors?
No
Yes
Write Additional
Sector Addresses
• Each additional cycle must be written within tSEA timeout
• Timeout resets after each additional cycle is written
• The host system may monitor DQ3 or wait tSEA to ensure
acceptance of erase commands
No
Yes
Poll DQ3.
DQ3 = 1?
Last Sector
Selected?
• No limit on number of sectors
• Commands other than Erase Suspend or selecting
additional sectors for erasure during timeout reset device
to reading array data
No
Yes
Wait 4 µs
Perform Write Operation
Status Algorithm
Yes
Status may be obtained by reading DQ7, DQ6 and/or DQ2.
Done?
No
DQ5 = 1?
No
Error condition (Exceeded Timing Limits)
Yes
PASS. Device returns
to reading array.
FAIL. Write reset command
to return to reading array.
Notes:
1.
2.
See Table 13.1 for erase command sequence.
See the section on DQ3 for information on the sector erase timeout.
Figure 8.5
38
Sector Erase Operation
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
8.5.4
I n f o r m a t i o n
Chip Erase Command Sequence
Chip erase is a six-bus cycle operation as indicated by Table 13.1. These commands invoke the
Embedded Erase algorithm, which does not require the system to preprogram prior to erase. The
Embedded Erase algorithm automatically preprograms and verifies the entire memory for an all
zero data pattern prior to electrical erase. After a successful chip erase, all locations of the chip
contain FFFFh. The system is not required to provide any controls or timings during these operations. Table 13.1 and Table 13.2 in the appendix show the address and data requirements for
the chip erase command sequence.
When the Embedded Erase algorithm is complete, that bank returns to the read mode and addresses are no longer latched. The system can determine the status of the erase operation by
using DQ7 or DQ6/DQ2. See Write Operation Status for information on these status bits.
Any commands written during the chip erase operation are ignored. However, note that a hardware reset immediately terminates the erase operation. If that occurs, the chip erase command
sequence should be reinitiated once that bank has returned to reading array data, to ensure data
integrity.
Software Functions and Sample Code
Table 8.15
Chip Erase
(LLD Function = lld_ChipEraseCmd)
Cycle
Description
Operation
Byte Address
Word Address
Data
1
Unlock
Write
Base + AAAh
Base + 555h
00AAh
2
Unlock
Write
Base + 554h
Base + 2AAh
0055h
3
Setup Command
Write
Base + AAAh
Base + 555h
0080h
4
Unlock
Write
Base + AAAh
Base + 555h
00AAh
5
Unlock
Write
Base + 554h
Base + 2AAh
0055h
6
Chip Erase Command
Write
Base + AAAh
Base + 555h
0010h
The following is a C source code example of using the chip erase function. Refer to the Spansion Low Level Driver User’s Guide (available on www.amd.com and www.fujitsu.com) for
general information on Spansion Flash memory software development guidelines.
/* Example: Chip Erase Command */
/* Note: Cannot be suspended
*/
*( (UINT16 *)base_addr + 0x555 )
*( (UINT16 *)base_addr + 0x2AA )
*( (UINT16 *)base_addr + 0x555 )
*( (UINT16 *)base_addr + 0x555 )
*( (UINT16 *)base_addr + 0x2AA )
*( (UINT16 *)base_addr + 0x000 )
8.5.5
=
=
=
=
=
=
0x00AA;
0x0055;
0x0080;
0x00AA;
0x0055;
0x0010;
/*
/*
/*
/*
/*
/*
write
write
write
write
write
write
unlock cycle 1
*/
unlock cycle 2
*/
setup command
*/
additional unlock cycle 1 */
additional unlock cycle 2 */
chip erase command
*/
Erase Suspend/Erase Resume Commands
When the Erase Suspend command is written during the sector erase time-out, the device immediately terminates the time-out period and suspends the erase operation. The Erase Suspend
command allows the system to interrupt a sector erase operation and then read data from, or
program data to, any sector not selected for erasure. The bank address is required when writing
this command. This command is valid only during the sector erase operation, including the minimum tSEA time-out period during the sector erase command sequence. The Erase Suspend
command is ignored if written during the chip erase operation.
When the Erase Suspend command is written after the tSEA time-out period has expired and during the sector erase operation, the device requires a maximum of tESL (erase suspend latency) to
suspend the erase operation.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
39
A d v a n c e
I n f o r m a t i o n
After the erase operation has been suspended, the bank enters the erase-suspend-read mode.
The system can read data from or program data to any sector not selected for erasure. (The device erase suspends all sectors selected for erasure.) Reading at any address within erasesuspended sectors produces status information on DQ7-DQ0. The system can use DQ7, or DQ6,
and DQ2 together, to determine if a sector is actively erasing or is erase-suspended. Refer to
Table 8.23 for information on these status bits.
After an erase-suspended program operation is complete, the bank returns to the erase-suspendread mode. The system can determine the status of the program operation using the DQ7 or DQ6
status bits, just as in the standard program operation.
In the erase-suspend-read mode, the system can also issue the Autoselect command sequence.
See Write Buffer Programming and Autoselect for details.
To resume the sector erase operation, the system must write the Erase Resume command. The
bank address of the erase-suspended bank is required when writing this command. Further writes
of the Resume command are ignored. Another Erase Suspend command can be written after the
chip has resumed erasing.
Software Functions and Sample Code
Table 8.16
Erase Suspend
(LLD Function = lld_EraseSuspendCmd)
Cycle
Operation
Byte Address
Word Address
Data
1
Write
Bank Address
Bank Address
00B0h
The following is a C source code example of using the erase suspend function. Refer to the
Spansion Low Level Driver User’s Guide (available on www.amd.com and www.fujitsu.com)
for general information on Spansion Flash memory software development guidelines.
/* Example: Erase suspend command */
*( (UINT16 *)bank_addr + 0x000 ) = 0x00B0;
/* write suspend command
Table 8.17
*/
Erase Resume
(LLD Function = lld_EraseResumeCmd)
Cycle
Operation
Byte Address
Word Address
Data
1
Write
Bank Address
Bank Address
0030h
The following is a C source code example of using the erase resume function. Refer to the
Spansion Low Level Driver User’s Guide (available on www.amd.com and www.fujitsu.com)
for general information on Spansion Flash memory software development guidelines.
/* Example: Erase resume command */
*( (UINT16 *)bank_addr + 0x000 ) = 0x0030;
/* write resume command
/* The flash needs adequate time in the resume state */
8.5.6
*/
Program Suspend/Program Resume Commands
The Program Suspend command allows the system to interrupt an embedded programming operation or a Write to Buffer programming operation so that data can read from any nonsuspended sector. When the Program Suspend command is written during a programming process, the device halts the programming operation within tPSL (program suspend latency) and
updates the status bits. Addresses are don't-cares when writing the Program Suspend command.
40
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
After the programming operation has been suspended, the system can read array data from any
non-suspended sector. The Program Suspend command may also be issued during a programming operation while an erase is suspended. In this case, data may be read from any addresses
not in Erase Suspend or Program Suspend. If a read is needed from the Secured Silicon Sector
area, then user must use the proper command sequences to enter and exit this region.
The system may also write the Autoselect command sequence when the device is in Program Suspend mode. The device allows reading Autoselect codes in the suspended sectors, since the codes
are not stored in the memory array. When the device exits the Autoselect mode, the device reverts to Program Suspend mode, and is ready for another valid operation. See Autoselect for
more information.
After the Program Resume command is written, the device reverts to programming. The system
can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in
the standard program operation. See Write Operation Status for more information.
The system must write the Program Resume command (address bits are don't care) to exit the
Program Suspend mode and continue the programming operation. Further writes of the Program
Resume command are ignored. Another Program Suspend command can be written after the device has resumed programming.
Software Functions and Sample Code
Table 8.18
Program Suspend
(LLD Function = lld_ProgramSuspendCmd)
Cycle
Operation
Byte Address
Word Address
Data
1
Write
Bank Address
Bank Address
00B0h
The following is a C source code example of using the program suspend function. Refer to the
Spansion Low Level Driver User’s Guide (available on www.amd.com and www.fujitsu.com)
for general information on Spansion Flash memory software development guidelines.
/* Example: Program suspend command */
*( (UINT16 *)base_addr + 0x000 ) = 0x00B0;
Table 8.19
/* write suspend command
*/
Program Resume
(LLD Function = lld_ProgramResumeCmd)
Cycle
Operation
Byte Address
Word Address
Data
1
Write
Bank Address
Bank Address
0030h
The following is a C source code example of using the program resume function. Refer to the
Spansion Low Level Driver User’s Guide (available on www.amd.com and www.fujitsu.com)
for general information on Spansion Flash memory software development guidelines.
/* Example: Program resume command */
*( (UINT16 *)base_addr + 0x000 ) = 0x0030;
8.5.7
/* write resume command
*/
Accelerated Program/Chip Erase
Accelerated single word programming, write buffer programming, sector erase, and chip erase
operations are enabled through the ACC function. This method is faster than the standard chip
program and erase command sequences.
The accelerated chip program and erase functions must not be used more than 10 times
per sector. In addition, accelerated chip program and erase should be performed at room temperature (25°C ±10°C).
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
41
A d v a n c e
I n f o r m a t i o n
If the system asserts VHH on this input, the device automatically enters the aforementioned Unlock Bypass mode and uses the higher voltage on the input to reduce the time required for
program and erase operations. The system can then use the Write Buffer Load command sequence provided by the Unlock Bypass mode. Note that if a Write-to-Buffer-Abort Reset is
required while in Unlock Bypass mode, the full 3-cycle RESET command sequence must be used
to reset the device. Removing VHH from the ACC input, upon completion of the embedded program or erase operation, returns the device to normal operation.
„ Sectors must be unlocked prior to raising ACC to VHH.
„ The ACC pin must not be at VHH for operations other than accelerated programming and accelerated chip erase, or device damage may result.
„ The ACC pin must not be left floating or unconnected; inconsistent behavior of the device may
result.
„ ACC locks all sector if set to VIL. ACC should be set to VIH for all other conditions.
8.5.8
Unlock Bypass
The device features an Unlock Bypass mode to facilitate faster word programming. Once the device enters the Unlock Bypass mode, only two write cycles are required to program data, instead
of the normal four cycles.
This mode dispenses with the initial two unlock cycles required in the standard program command
sequence, resulting in faster total programming time. See the Appendix for the requirements for
the unlock bypass command sequences.
During the unlock bypass mode, only the Read, Unlock Bypass Program and Unlock Bypass Reset
commands are valid. To exit the unlock bypass mode, the system must issue the two-cycle unlock
bypass reset command sequence. The first cycle must contain the bank address and the data 90h.
The second cycle need only contain the data 00h. The bank then returns to the read mode.
42
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Software Functions and Sample Code
The following are C source code examples of using the unlock bypass entry, program, and exit
functions. Refer to the Spansion Low Level Driver User’s Guide (available soon on www.amd.com
and www.fujitsu.com) for general information on Spansion Flash “memory software development
guidelines.
Table 8.20
Unlock Bypass Entry
(LLD Function = lld_UnlockBypassEntryCmd)
Cycle
Description
Operation
Byte Address
Word Address
Data
1
Unlock
Write
Base + AAAh
Base + 555h
00AAh
2
Unlock
Write
Base + 554h
Base + 2AAh
0055h
3
Entry Command
Write
Base + AAAh
Base + 555h
0020h
/* Example: Unlock Bypass Entry Command
*/
*( (UINT16 *)bank_addr + 0x555 ) = 0x00AA;
/* write unlock
*( (UINT16 *)bank_addr + 0x2AA ) = 0x0055;
/* write unlock
*( (UINT16 *)bank_addr + 0x555 ) = 0x0020;
/* write unlock
/* At this point, programming only takes two write cycles.
/* Once you enter Unlock Bypass Mode, do a series of like
/* operations (programming or sector erase) and then exit
/* Unlock Bypass Mode before beginning a different type of
/* operations.
Table 8.21
cycle 1
cycle 2
bypass command
*/
*/
*/
*/
*/
*/
*/
*/
Unlock Bypass Program
(LLD Function = lld_UnlockBypassProgramCmd)
Cycle
Description
Operation
Byte Address
Word Address
Data
1
Program Setup Command
Write
Base + xxxh
Base +xxxh
00A0h
2
Program Command
Write
Program Address
Program Address
Program Data
/* Example: Unlock Bypass Program Command */
/* Do while in Unlock Bypass Entry Mode!
*/
*( (UINT16 *)bank_addr + 0x555 ) = 0x00A0;
*( (UINT16 *)pa )
= data;
/* Poll until done or error.
*/
/* If done and more to program, */
/* do above two cycles again.
*/
Table 8.22
/* write program setup command
/* write data to be programmed
*/
*/
Unlock Bypass Reset
(LLD Function = lld_UnlockBypassResetCmd)
Cycle
Description
Operation
Byte Address
Word Address
Data
1
Reset Cycle 1
Write
Base + xxxh
Base +xxxh
0090h
2
Reset Cycle 2
Write
Base + xxxh
Base +xxxh
0000h
/* Example: Unlock Bypass Exit Command */
*( (UINT16 *)base_addr + 0x000 ) = 0x0090;
*( (UINT16 *)base_addr + 0x000 ) = 0x0000;
8.5.9
Write Operation Status
The device provides several bits to determine the status of a program or erase operation. The
following subsections describe the function of DQ1, DQ2, DQ3, DQ5, DQ6, and DQ7.
DQ7: Data# Polling. The Data# Polling bit, DQ7, indicates to the host system whether an Em-
bedded Program or Erase algorithm is in progress or completed, or whether a bank is in Erase
Suspend. Data# Polling is valid after the rising edge of the final WE# pulse in the command se-
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
43
A d v a n c e
I n f o r m a t i o n
quence. Note that the Data# Polling is valid only for the last word being programmed in the writebuffer-page during Write Buffer Programming. Reading Data# Polling status on any word other
than the last word to be programmed in the write-buffer-page returns false status information.
During the Embedded Program algorithm, the device outputs on DQ7 the complement of the
datum programmed to DQ7. This DQ7 status also applies to programming during Erase Suspend.
When the Embedded Program algorithm is complete, the device outputs the datum programmed
to DQ7. The system must provide the program address to read valid status information on DQ7.
If a program address falls within a protected sector, Data# polling on DQ7 is active for approximately tPSP, then that bank returns to the read mode.
During the Embedded Erase Algorithm, Data# polling produces a 0 on DQ7. When the Embedded
Erase algorithm is complete, or if the bank enters the Erase Suspend mode, Data# Polling produces a 1 on DQ7. The system must provide an address within any of the sectors selected for
erasure to read valid status information on DQ7.
After an erase command sequence is written, if all sectors selected for erasing are protected,
Data# Polling on DQ7 is active for approximately tASP, then the bank returns to the read mode.
If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected
sectors, and ignores the selected sectors that are protected. However, if the system reads DQ7
at an address within a protected sector, the status may not be valid.
Just prior to the completion of an Embedded Program or Erase operation, DQ7 may change asynchronously with DQ6-DQ0 while Output Enable (OE#) is asserted low. That is, the device may
change from providing status information to valid data on DQ7. Depending on when the system
samples the DQ7 output, it may read the status or valid data. Even if the device has completed
the program or erase operation and DQ7 has valid data, the data outputs on DQ6-DQ0 may be
still invalid. Valid data on DQ7-D00 appears on successive read cycles.
See the following for more information: Table 8.23, Write Operation Status, shows the outputs
for Data# Polling on DQ7. Figure 8.6, Write Operation Status Flowchart, shows the Data# Polling
algorithm; and Figure 12.17, Data# Polling Timings (During Embedded Algorithm), shows the
Data# Polling timing diagram.
44
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
START
Read 1
(Note 6)
YES
Erase
Operation
Complete
DQ7=valid
data?
NO
Read 1
DQ5=1?
YES
YES
Read 2
Read3=
valid data?
NO
NO
Read 3
Read 2
YES
Program
Operation
Failed
Write Buffer
Programming?
YES
NO
Programming
Operation?
Read 3
NO
Device BUSY,
Re-Poll
(Note 3)
(Note 1)
(Note 4)
(Note 1)
YES
DQ6
toggling?
DQ6
toggling?
TIMEOUT
NO
YES
Read3
DQ1=1?
DEVICE
ERROR
NO
(Note 2)
NO
(Note 5)
YES
Device BUSY,
Re-Poll
DQ2
toggling?
YES
NO
Read 2
Device BUSY,
Re-Poll
Erase
Operation
Complete
Read 3
Read3
DQ1=1
AND DQ7 ≠
Valid Data?
YES
Device in
Erase/Suspend
Mode
Write Buffer
Operation
Failed
NO
Notes:
1) DQ6 is toggling if Read2 DQ6 does not equal Read3 DQ6.
2) DQ2 is toggling if Read2 DQ2 does not equal Read3 DQ2.
3) May be due to an attempt to program a 0 to 1. Use the RESET
command to exit operation.
4) Write buffer error if DQ1 of last read =1.
5) Invalid state, use RESET command to exit operation.
6) Valid data is the data that is intended to be programmed or all 1's for
an erase operation.
7) Data polling algorithm valid for all operations except advanced sector
protection.
Device BUSY,
Re-Poll
Figure 8.6
March 14, 2005 S70WS512N00_00_A0
Write Operation Status Flowchart
S70WS512N00 Based MCPs
45
A d v a n c e
I n f o r m a t i o n
DQ6: Toggle Bit I . Toggle Bit I on DQ6 indicates whether an Embedded Program or Erase algorithm is in progress or complete, or whether the device has entered the Erase Suspend mode.
Toggle Bit I may be read at any address in the same bank, and is valid after the rising edge of
the final WE# pulse in the command sequence (prior to the program or erase operation), and during the sector erase time-out.
During an Embedded Program or Erase algorithm operation, successive read cycles to any address cause DQ6 to toggle. When the operation is complete, DQ6 stops toggling.
After an erase command sequence is written, if all sectors selected for erasing are protected, DQ6
toggles for approximately tASP [all sectors protected toggle time], then returns to reading array
data. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected.
The system can use DQ6 and DQ2 together to determine whether a sector is actively erasing or
is erase-suspended. When the device is actively erasing (that is, the Embedded Erase algorithm
is in progress), DQ6 toggles. When the device enters the Erase Suspend mode, DQ6 stops toggling. However, the system must also use DQ2 to determine which sectors are erasing or erasesuspended. Alternatively, the system can use DQ7 (see the subsection on DQ7: Data# Polling).
If a program address falls within a protected sector, DQ6 toggles for approximately tPAP after the
program command sequence is written, then returns to reading array data.
DQ6 also toggles during the erase-suspend-program mode, and stops toggling once the Embedded Program Algorithm is complete.
See the following for additional information: Figure 8.6, Write Operation Status Flowchart;
Figure 12.18, Toggle Bit Timings (During Embedded Algorithm), and Table 8.23 and Table 8.24.
Toggle Bit I on DQ6 requires either OE# or CE# to be de-asserted and reasserted to show the
change in state.
DQ2: Toggle Bit II . The Toggle Bit II on DQ2, when used with DQ6, indicates whether a partic-
ular sector is actively erasing (that is, the Embedded Erase algorithm is in progress), or whether
that sector is erase-suspended. Toggle Bit II is valid after the rising edge of the final WE# pulse
in the command sequence. DQ2 toggles when the system reads at addresses within those sectors
that have been selected for erasure. But DQ2 cannot distinguish whether the sector is actively
erasing or is erase-suspended. DQ6, by comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot distinguish which sectors are selected for erasure. Thus,
both status bits are required for sector and mode information. Refer to Table 8.23 to compare
outputs for DQ2 and DQ6. See the following for additional information: Figure 8.6, the DQ6: Toggle Bit I section, and Figures 12.17–12.20.
Reading Toggle Bits DQ6/DQ2. Whenever the system initially begins reading toggle bit status,
it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is toggling. Typically, the system would note and store the value of the toggle bit after the first read. After the
second read, the system would compare the new value of the toggle bit with the first. If the toggle
bit is not toggling, the device has completed the program or erases operation. The system can
read array data on DQ7–DQ0 on the following read cycle. However, if after the initial two read
cycles, the system determines that the toggle bit is still toggling, the system also should note
whether the value of DQ5 is high (see the section on DQ5). If it is, the system should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling just
as DQ5 went high. If the toggle bit is no longer toggling, the device has successfully completed
the program or erases operation. If it is still toggling, the device did not complete the operation
successfully, and the system must write the reset command to return to reading array data. The
remaining scenario is that the system initially determines that the toggle bit is toggling and DQ5
has not gone high. The system may continue to monitor the toggle bit and DQ5 through successive read cycles, determining the status as described in the previous paragraph. Alternatively, it
46
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
may choose to perform other system tasks. In this case, the system must start at the beginning
of the algorithm when it returns to determine the status of the operation. Refer to Figure 8.6 for
more details.
DQ5: Exceeded Timing Limits. DQ5 indicates whether the program or erase time has exceeded
a specified internal pulse count limit. Under these conditions DQ5 produces a 1, indicating that
the program or erase cycle was not successfully completed. The device may output a 1 on DQ5 if
the system tries to program a 1 to a location that was previously programmed to 0 Only an erase
operation can change a 0 back to a 1. Under this condition, the device halts the operation, and
when the timing limit has been exceeded, DQ5 produces a 1. Under both these conditions, the
system must write the reset command to return to the read mode (or to the erase-suspend-read
mode if a bank was previously in the erase-suspend-program mode).
DQ3: Sector Erase Timeout State Indicator. After writing a sector erase command sequence,
the system may read DQ3 to determine whether or not erasure has begun. (The sector erase
timer does not apply to the chip erase command.) If additional sectors are selected for erasure,
the entire time-out also applies after each additional sector erase command. When the time-out
period is complete, DQ3 switches from a 0 to a 1. If the time between additional sector erase
commands from the system can be assumed to be less than tSEA, the system need not monitor
DQ3. See Sector Erase Command Sequence for more details.
After the sector erase command is written, the system should read the status of DQ7 (Data# Polling) or DQ6 (Toggle Bit I) to ensure that the device has accepted the command sequence, and
then read DQ3. If DQ3 is 1, the Embedded Erase algorithm has begun; all further commands (except Erase Suspend) are ignored until the erase operation is complete. If DQ3 is 0 the device
accepts additional sector erase commands. To ensure the command has been accepted, the system software should check the status of DQ3 prior to and following each sub-sequent sector erase
command. If DQ3 is high on the second status check, the last command might not have been
accepted. Table 8.23 shows the status of DQ3 relative to the other status bits.
DQ1: Write to Buffer Abort. DQ1 indicates whether a Write to Buffer operation was aborted.
Under these conditions DQ1 produces a 1. The system must issue the Write to Buffer Abort Reset
command sequence to return the device to reading array data. See Write Buffer Programming
Operation for more details.
Table 8.23
Program
Suspend
Mode
(Note 3)
Write to
Buffer
(Note 5)
Write Operation Status
INVALID
INVALID
INVALID
INVALID
INVALID
INVALID
(Not
Allowed)
(Not
Allowed)
(Not
Allowed)
(Not
Allowed)
(Not
Allowed)
(Not
Allowed)
Reading within Non-Program Suspended
Sector
Data
Data
Data
Data
Data
Data
BUSY State
DQ7#
Toggle
0
N/A
N/A
0
Exceeded Timing Limits
DQ7#
Toggle
1
N/A
N/A
0
ABORT State
DQ7#
Toggle
0
N/A
N/A
1
Reading within Program Suspended Sector
Notes:
1.
2.
3.
4.
5.
DQ5 switches to 1 when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits. Refer to the
section on DQ5 for more information.
DQ7 a valid address when reading status information. Refer to the appropriate subsection for further details.
Data are invalid for addresses in a Program Suspended sector.
DQ1 indicates the Write to Buffer ABORT status during Write Buffer Programming operations.
The data-bar polling algorithm should be used for Write Buffer Programming operations. Note that DQ7# during Write Buffer Programming
indicates the data-bar for DQ7 data for the Last Loaded Write-buffer Address location.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
47
A d v a n c e
8.6
I n f o r m a t i o n
Simultaneous Read/Write
The simultaneous read/write feature allows the host system to read data from one bank of memory while programming or erasing another bank of memory. An erase operation may also be
suspended to read from or program another location within the same bank (except the sector
being erased). Figure 12.24, Back-to-Back Read/Write Cycle Timings, shows how read and write
cycles may be initiated for simultaneous operation with zero latency. Refer to the DC Characteristics table for read-while-program and read-while-erase current specification.
8.7
Writing Commands/Command Sequences
When the device is configured for Asynchronous read, only Asynchronous write operations are
allowed, and CLK is ignored. When in the Synchronous read mode configuration, the device is able
to perform both Asynchronous and Synchronous write operations. CLK and AVD# induced address
latches are supported in the Synchronous programming mode. During a synchronous write operation, to write a command or command sequence (which includes programming data to the
device and erasing sectors of memory), the system must drive AVD# and CE# to VIL, and OE#
to VIH when providing an address to the device, and drive WE# and CE# to VIL, and OE# to VIH
when writing commands or data. During an asynchronous write operation, the system must drive
CE# and WE# to VIL and OE# to VIH when providing an address, command, and data. Addresses
are latched on the last falling edge of WE# or CE#, while data is latched on the 1st rising edge of
WE# or CE#. An erase operation can erase one sector, multiple sectors, or the entire device.
Tables 7.1–7.3 indicate the address space that each sector occupies. The device address space is
divided into sixteen banks: Banks 1 through 14 contain only 64 Kword sectors, while Banks 0 and
15 contain both 16 Kword boot sectors in addition to 64 Kword sectors. A bank address is the set
of address bits required to uniquely select a bank. Similarly, a sector address is the address bits
required to uniquely select a sector. ICC2 in DC Characteristics represents the active current specification for the write mode. AC Characteristics-Synchronous and AC Characteristics—
Asynchronous Read contains timing specification tables and timing diagrams for write operations.
8.8
Handshaking
The handshaking feature allows the host system to detect when data is ready to be read by simply
monitoring the RDY (Ready) pin, which is a dedicated output and controlled by CE#.
When the device is configured to operate in synchronous mode, and OE# is low (active), the initial
word of burst data becomes available after either the falling or rising edge of the RDY pin (depending on the setting for bit 10 in the Configuration Register). It is recommended that the host
system set CR13–CR11 in the Configuration Register to the appropriate number of wait states to
ensure optimal burst mode operation (see Table 8.8, Configuration Register).
Bit 8 in the Configuration Register allows the host to specify whether RDY is active at the same
time that data is ready, or one cycle before data is ready.
48
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
8.9
I n f o r m a t i o n
Hardware Reset
The RESET# input provides a hardware method of resetting the device to reading array data.
When RESET# is driven low for at least a period of tRP, the device immediately terminates any
operation in progress, tristates all outputs, resets the configuration register, and ignores all read/
write commands for the duration of the RESET# pulse. The device also resets the internal state
machine to reading array data.
To ensure data integrity the operation that was interrupted should be reinitiated once the device
is ready to accept another command sequence.
When RESET# is held at VSS, the device draws CMOS standby current (ICC4). If RESET# is held
at VIL, but not at VSS, the standby current is greater.
RESET# may be tied to the system reset circuitry which enables the system to read the boot-up
firmware from the Flash memory upon a system reset.
See Figures 12.5 and 12.12 for timing diagrams.
8.10
Software Reset
Software reset is part of the command set (see Table 13.1) that also returns the device to array
read mode and must be used for the following conditions:
1.
to exit Autoselect mode
2.
when DQ5 goes high during write status operation that indicates program or erase cycle was
not successfully completed
3.
exit sector lock/unlock operation.
4.
to return to erase-suspend-read mode if the device was previously in Erase Suspend mode.
5.
after any aborted operations
Software Functions and Sample Code
Table 8.24
Reset
(LLD Function = lld_ResetCmd)
Cycle
Operation
Byte Address
Word Address
Data
Reset Command
Write
Base + xxxh
Base + xxxh
00F0h
Note: Base = Base Address.
The following is a C source code example of using the reset function. Refer to the Spansion
Low Level Driver User’s Guide (available on www.amd.com and www.fujitsu.com) for general
information on Spansion Flash memory software development guidelines.
/* Example: Reset (software reset of Flash state machine) */
*( (UINT16 *)base_addr + 0x000 ) = 0x00F0;
The following are additional points to consider when using the reset command:
„ This command resets the banks to the read and address bits are ignored.
„ Reset commands are ignored once erasure has begun until the operation is complete.
„ Once programming begins, the device ignores reset commands until the operation is complete
„ The reset command may be written between the cycles in a program command sequence before programming begins (prior to the third cycle). This resets the bank to which the system
was writing to the read mode.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
49
A d v a n c e
I n f o r m a t i o n
„ If the program command sequence is written to a bank that is in the Erase Suspend mode,
writing the reset command returns that bank to the erase-suspend-read mode.
„ The reset command may be also written during an Autoselect command sequence.
„ If a bank has entered the Autoselect mode while in the Erase Suspend mode, writing the reset
command returns that bank to the erase-suspend-read mode.
„ If DQ1 goes high during a Write Buffer Programming operation, the system must write the
Write to Buffer Abort Reset command sequence to RESET the device to reading array data.
The standard RESET command does not work during this condition.
„ To exit the unlock bypass mode, the system must issue a two-cycle unlock bypass reset command sequence [see command table for details].
50
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
9
I n f o r m a t i o n
Advanced Sector Protection/Unprotection
The Advanced Sector Protection/Unprotection feature disables or enables programming or erase
operations in any or all sectors and can be implemented through software and/or hardware methods, which are independent of each other. This section describes the various methods of
protecting data stored in the memory array. An overview of these methods in shown in Figure 9.1.
Hardware Methods
Software Methods
Lock Register
(One Time Programmable)
ACC = VIL
(All sectors locked)
Password Method
Persistent Method
(DQ2)
(DQ1)
WP# = VIL
(All boot
sectors locked)
64-bit Password
(One Time Protect)
PPB Lock Bit1,2,3
0 = PPBs Locked
1 = PPBs Unlocked
1. Bit is volatile, and defaults to “1” on
reset.
2. Programming to “0” locks all PPBs to
their current state.
3. Once programmed to “0”, requires
hardware reset to unlock.
Memory Array
Persistent
Protection Bit
(PPB)4,5
Sector 0
PPB 0
DYB 0
Sector 1
PPB 1
DYB 1
Sector 2
PPB 2
DYB 2
Sector N-2
PPB N-2
DYB N-2
Sector N-1
PPB N-1
DYB N-1
PPB N
DYB N
3
Sector N
3. N = Highest Address Sector.
4. 0 = Sector Protected,
1 = Sector Unprotected.
5. PPBs programmed individually,
but cleared collectively
Figure 9.1
March 14, 2005 S70WS512N00_00_A0
Dynamic
Protection Bit
(PPB)6,7,8
6. 0 = Sector Protected,
1 = Sector Unprotected.
7. Protect effective only if PPB Lock Bit
is unlocked and corresponding PPB
is “1” (unprotected).
8. Volatile Bits: defaults to user choice
upon power-up (see ordering
options).
Advanced Sector Protection/Unprotection
S70WS512N00 Based MCPs
51
A d v a n c e
9.1
I n f o r m a t i o n
Lock Register
As shipped from the factory, all devices default to the persistent mode when power is applied, and
all sectors are unprotected, unless otherwise chosen through the DYB ordering option. The device
programmer or host system must then choose which sector protection method to use. Programming (setting to 0) any one of the following two one-time programmable, non-volatile bits locks
the part permanently in that mode:
„ Lock Register Persistent Protection Mode Lock Bit (DQ1)
„ Lock Register Password Protection Mode Lock Bit (DQ2)
Table 9.1
Lock Register
Device
DQ15-05
DQ4
DQ3
DQ2
DQ1
DQ0
S29WS256N
1
1
1
Password
Protection
Mode Lock Bit
Persistent
Protection
Mode Lock Bit
Customer
Secured Silicon
Sector
Protection Bit
Password
Protection
Mode Lock Bit
Persistent
Protection
Mode Lock Bit
Secured Silicon
Sector
Protection Bit
DYB Lock Boot Bit
S29WS128N/
S29WS064N
Undefined
0 = sectors
power up
protected
1 = sectors
power up
unprotected
PPB One-Time
Programmable Bit
0 = All PPB erase
command disabled
1 = All PPB Erase
command enabled
For programming lock register bits refer to Table 13.2.
Notes
1. If the password mode is chosen, the password must be programmed before setting the corresponding lock register bit.
2. After the Lock Register Bits Command Set Entry command sequence is written, reads and
writes for Bank 0 are disabled, while reads from other banks are allowed until exiting this
mode.
3. If both lock bits are selected to be programmed (to zeros) at the same time, the operation
aborts.
4. Once the Password Mode Lock Bit is programmed, the Persistent Mode Lock Bit is permanently
disabled, and no changes to the protection scheme are allowed. Similarly, if the Persistent
Mode Lock Bit is programmed, the Password Mode is permanently disabled.
After selecting a sector protection method, each sector can operate in any of the following three
states:
1.
Constantly locked. The selected sectors are protected and can not be reprogrammed unless
PPB lock bit is cleared via a password, hardware reset, or power cycle.
2.
Dynamically locked. The selected sectors are protected and can be altered via software
commands.
3.
Unlocked. The sectors are unprotected and can be erased and/or programmed.
These states are controlled by the bit types described in Sections 9.2–9.6.
9.2
Persistent Protection Bits
The Persistent Protection Bits are unique and nonvolatile for each sector and have the same endurances as the Flash memory. Preprogramming and verification prior to erasure are handled by
the device, and therefore do not require system monitoring.
52
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Notes
1.
Each PPB is individually programmed and all are erased in parallel.
2.
While programming PPB for a sector, array data can be read from any other bank, except
Bank 0 (used for Data# Polling) and the bank in which sector PPB is being programmed.
3.
Entry command disables reads and writes for the bank selected.
4.
Reads within that bank return the PPB status for that sector.
5.
Reads from other banks are allowed while writes are not allowed.
6.
All Reads must be performed using the Asynchronous mode.
7.
The specific sector address (A23-A14 WS256N, A22-A14 WS128N, A21-A14 WS064N) are
written at the same time as the program command.
8.
If the PPB Lock Bit is set, the PPB Program or erase command does not execute and timesout without programming or erasing the PPB.
9.
There are no means for individually erasing a specific PPB and no specific sector address is
required for this operation.
10. Exit command must be issued after the execution which resets the device to read mode and
re-enables reads and writes for Bank 0
11. The programming state of the PPB for a given sector can be verified by writing a PPB
Status Read Command to the device as described by the flow chart shown in Figure 9.2.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
53
A d v a n c e
I n f o r m a t i o n
Enter PPB
Command Set.
Addr = BA
Program PPB Bit.
Addr = SA
Read Byte Twice
Addr = SA0
No
DQ6 =
Toggle?
Yes
No
DQ5 = 1?
Wait 500 µs
Yes
Read Byte Twice
Addr = SA0
DQ6 =
Toggle?
No
Read Byte.
Addr = SA
Yes
No
DQ0 =
'1' (Erase)
'0' (Pgm.)?
FAIL
Yes
Issue Reset
Command
PASS
Exit PPB
Command Set
Figure 9.2
9.3
PPB Program/Erase Algorithm
Dynamic Protection Bits
Dynamic Protection Bits are volatile and unique for each sector and can be individually modified.
DYBs only control the protection scheme for unprotected sectors that have their PPBs cleared
(erased to 1). By issuing the DYB Set or Clear command sequences, the DYBs are set (programmed to 0) or cleared (erased to 1), thus placing each sector in the protected or unprotected
state respectively. This feature allows software to easily protect sectors against inadvertent
changes yet does not prevent the easy removal of protection when changes are needed.
54
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Notes
1.
The DYBs can be set (programmed to 0) or cleared (erased to 1) as often as needed.
When the parts are first shipped, the PPBs are cleared (erased to 1) and upon power up or reset,
the DYBs can be set or cleared depending upon the ordering option chosen.
9.4
2.
If the option to clear the DYBs after power up is chosen, (erased to 1), then the sectorsmay
be modified depending upon the PPB state of that sector (see Table 9.2).
3.
The sectors would be in the protected state If the option to set the DYBs after power up is
chosen (programmed to 0).
4.
It is possible to have sectors that are persistently locked with sectors that are left in the
dynamic state.
5.
The DYB Set or Clear commands for the dynamic sectors signify protected or unprotected
state of the sectors respectively. However, if there is a need to change the status of the persistently locked sectors, a few more steps are required. First, the PPB Lock Bit must be
cleared by either putting the device through a power-cycle, or hardware reset. The PPBs can
then be changed to reflect the desired settings. Setting the PPB Lock Bit once again locks
the PPBs, and the device operates normally again.
6.
To achieve the best protection, it is recommended to execute the PPB Lock Bit Set command
early in the boot code and protect the boot code by holding WP# = VIL. Note that the PPB
and DYB bits have the same function when ACC = VHH as they do when ACC =VIH.
Persistent Protection Bit Lock Bit
The Persistent Protection Bit Lock Bit is a global volatile bit for all sectors. When set (programmed
to 0), it locks all PPBs and when cleared (programmed to 1), allows the PPBs to be changed. There
is only one PPB Lock Bit per device.
Notes
9.5
1.
No software command sequence unlocks this bit unless the device is in the password protection mode; only a hardware reset or a power-up clears this bit.
2.
The PPB Lock Bit must be set (programmed to 0) only after all PPBs are configured to the
desired settings.
Password Protection Method
The Password Protection Method allows an even higher level of security than the Persistent Sector
Protection Mode by requiring a 64 bit password for unlocking the device PPB Lock Bit. In addition
to this password requirement, after power up and reset, the PPB Lock Bit is set 0 to maintain the
password mode of operation. Successful execution of the Password Unlock command by entering
the entire password clears the PPB Lock Bit, allowing for sector PPBs modifications.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
55
A d v a n c e
I n f o r m a t i o n
Notes
1.
There is no special addressing order required for programming the password. Once the
Password is written and verified, the Password Mode Locking Bit must be set in order to prevent access.
2.
The Password Program Command is only capable of programming 0s. Programming a 1 after
a cell is programmed as a 0 results in a time-out with the cell as a 0.
3.
The password is all 1s when shipped from the factory.
4.
All 64-bit password combinations are valid as a password.
5.
There is no means to verify what the password is after it is set.
6.
The Password Mode Lock Bit, once set, prevents reading the 64-bit password on the data
bus and further password programming.
7.
The Password Mode Lock Bit is not erasable.
8.
The lower two address bits (A1–A0) are valid during the Password Read, Password Program,
and Password Unlock.
9.
The exact password must be entered in order for the unlocking function to occur.
10. The Password Unlock command cannot be issued any faster than 1 µs at a time to prevent
a hacker from running through all the 64-bit combinations in an attempt to correctly match
a password.
11. Approximately 1 µs is required for unlocking the device after the valid 64-bit password is
given to the device.
12. Password verification is only allowed during the password programming operation.
13. All further commands to the password region are disabled and all operations are ignored.
14. If the password is lost after setting the Password Mode Lock Bit, there is no way to clear the
PPB Lock Bit.
15. Entry command sequence must be issued prior to any of any operation and it disables reads
and writes for Bank 0. Reads and writes for other banks excluding Bank 0 are allowed.
16. If the user attempts to program or erase a protected sector, the device ignores the command and returns to read mode.
17. A program or erase command to a protected sector enables status polling and returns to
read mode without having modified the contents of the protected sector.
18. The programming of the DYB, PPB, and PPB Lock for a given sector can be verified by writing
individual status read commands DYB Status, PPB Status, and PPB Lock Status to the
device.
56
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Write Unlock Cycles:
Address 555h, Data AAh
Address 2AAh, Data 55h
Unlock Cycle 1
Unlock Cycle 2
Write
Enter Lock Register Command:
Address 555h, Data 40h
XXXh = Address don’t care
Program Lock Register Data
Address XXXh, Data A0h
Address 77h*, Data PD
* Not on future devices
Program Data (PD): See text for Lock Register
definitions
Caution: Lock register can only be progammed
once.
Wait 4 µs
Perform Polling Algorithm
(see Write Operation Status
flowchart)
Yes
Done?
No
DQ5 = 1?
No
Error condition (Exceeded Timing Limits)
Yes
PASS. Write Lock Register
Exit Command:
Address XXXh, Data 90h
Address XXXh, Data 00h
Device returns to reading array.
FAIL. Write rest command
to return to reading array.
Figure 9.3
March 14, 2005 S70WS512N00_00_A0
Lock Register Program Algorithm
S70WS512N00 Based MCPs
57
A d v a n c e
9.6
I n f o r m a t i o n
Advanced Sector Protection Software Examples
Table 9.2
Unique Device PPB Lock Bit
0 = locked
1 = unlocked
Sector Protection Schemes
Sector PPB
0 = protected
1 = unprotected
Sector DYB
0 = protected
1 = unprotected
Sector Protection Status
Any Sector
0
0
x
Protected through PPB
Any Sector
0
0
x
Protected through PPB
Any Sector
0
1
1
Unprotected
Any Sector
0
1
0
Protected through DYB
Any Sector
1
0
x
Protected through PPB
Any Sector
1
0
x
Protected through PPB
Any Sector
1
1
0
Protected through DYB
Any Sector
1
1
1
Unprotected
Table 9.2 contains all possible combinations of the DYB, PPB, and PPB Lock Bit relating to the status of the sector. In summary, if the PPB Lock Bit is locked (set to 0), no changes to the PPBs are
allowed. The PPB Lock Bit can only be unlocked (reset to 1) through a hardware reset or power
cycle. See also Figure 9.1 for an overview of the Advanced Sector Protection feature.
9.7
Hardware Data Protection Methods
The device offers two main types of data protection at the sector level via hardware control:
„ When WP# is at VIL, the four outermost sectors are locked (device specific).
„ When ACC is at VIL, all sectors are locked.
There are additional methods by which intended or accidental erasure of any sectors can be prevented via hardware means. The following subsections describes these methods:
9.7.1
WP# Method
The Write Protect feature provides a hardware method of protecting the four outermost sectors.
This function is provided by the WP# pin and overrides the previously discussed Sector Protection/Unprotection method.
If the system asserts VIL on the WP# pin, the device disables program and erase functions in the
outermost boot sectors. The outermost boot sectors are the sectors containing both the lower and
upper set of sectors in a dual-boot-configured device.
If the system asserts VIH on the WP# pin, the device reverts to whether the boot sectors were
last set to be protected or unprotected. That is, sector protection or unprotection for these sectors
depends on whether they were last protected or unprotected.
Note that the WP# pin must not be left floating or unconnected as inconsistent behavior of the
device may result.
The WP# pin must be held stable during a command sequence execution
9.7.2
ACC Method
This method is similar to above, except it protects all sectors. Once ACC input is set to VIL, all
program and erase functions are disabled and hence all sectors are protected.
9.7.3
Low VCC Write Inhibit
When VCC is less than VLKO, the device does not accept any write cycles. This protects data during
VCC power-up and power-down.
58
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
The command register and all internal program/erase circuits are disabled, and the device resets
to reading array data. Subsequent writes are ignored until VCC is greater than VLKO. The system
must provide the proper signals to the control inputs to prevent unintentional writes when VCC is
greater than VLKO.
9.7.4
Write Pulse Glitch Protection
Noise pulses of less than 3 ns (typical) on OE#, CE# or WE# do not initiate a write cycle.
9.7.5
Power-Up Write Inhibit
If WE# = CE# = RESET# = VIL and OE# = VIH during power up, the device does not accept commands on the rising edge of WE#. The internal state machine is automatically reset to the read
mode on power-up.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
59
A d v a n c e
I n f o r m a t i o n
10 Power Conservation Modes
10.1
Standby Mode
When the system is not reading or writing to the device, it can place the device in the standby
mode. In this mode, current consumption is greatly reduced, and the outputs are placed in the
high impedance state, independent of the OE# input. The device enters the CMOS standby mode
when the CE# and RESET# inputs are both held at VCC ± 0.2 V. The device requires standard
access time (tCE) for read access, before it is ready to read data. If the device is deselected during
erasure or programming, the device draws active current until the operation is completed. ICC3
in DC Characteristics represents the standby current specification
10.2
Automatic Sleep Mode
The automatic sleep mode minimizes Flash device energy consumption while in asynchronous
mode. the device automatically enables this mode when addresses remain stable for tACC + 20
ns. The automatic sleep mode is independent of the CE#, WE#, and OE# control signals. Standard address access timings provide new data when addresses are changed. While in sleep mode,
output data is latched and always available to the system. While in synchronous mode, the automatic sleep mode is disabled. Note that a new burst operation is required to provide new data.
ICC6 in DC Characteristics represents the automatic sleep mode current specification.
10.3
Hardware RESET# Input Operation
The RESET# input provides a hardware method of resetting the device to reading array data.
When RESET# is driven low for at least a period of tRP, the device immediately terminates any
operation in progress, tristates all outputs, resets the configuration register, and ignores all read/
write commands for the duration of the RESET# pulse. The device also resets the internal state
machine to reading array data. The operation that was interrupted should be reinitiated once the
device is ready to accept another command sequence to ensure data integrity.
When RESET# is held at VSS ± 0.2 V, the device draws CMOS standby current (ICC4). If RESET#
is held at VIL but not within VSS ± 0.2 V, the standby current is greater.
RESET# may be tied to the system reset circuitry and thus, a system reset would also reset the
Flash memory, enabling the system to read the boot-up firmware from the Flash memory.
10.4
Output Disable (OE#)
When the OE# input is at VIH, output from the device is disabled. The outputs are placed in the
high impedance state.
60
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
11
I n f o r m a t i o n
Secured Silicon Sector Flash Memory Region
The Secured Silicon Sector provides an extra Flash memory region that enables permanent part
identification through an Electronic Serial Number (ESN). The Secured Silicon Sector is 256 words
in length that consists of 128 words for factory data and 128 words for customer-secured areas.
All Secured Silicon reads outside of the 256-word address range returns invalid data. The Factory
Indicator Bit, DQ7, (at Autoselect address 03h) is used to indicate whether or not the Factory Secured Silicon Sector is locked when shipped from the factory. The Customer Indicator Bit (DQ6)
is used to indicate whether or not the Customer Secured Silicon Sector is locked when shipped
from the factory.
Please note the following general conditions:
„ While Secured Silicon Sector access is enabled, simultaneous operations are allowed except
for Bank 0.
„ On power-up, or following a hardware reset, the device reverts to sending commands to the
normal address space.
„ Reads can be performed in the Asynchronous or Synchronous mode.
„ Burst mode reads within Secured Silicon Sector wrap from address FFh back to address 00h.
„ Reads outside of sector 0 return memory array data.
„ Continuous burst read past the maximum address is undefined.
„ Sector 0 is remapped from memory array to Secured Silicon Sector array.
„ Once the Secured Silicon Sector Entry Command is issued, the Secured Silicon Sector Exit
command must be issued to exit Secured Silicon Sector Mode.
„ The Secured Silicon Sector is not accessible when the device is executing an Embedded Program or Embedded Erase algorithm.
Table 11.1
Sector
Customer
Factory
11.1
Addresses
Sector Size
128 words
128 words
Address Range
000080h-0000FFh
000000h-00007Fh
Factory Secured SiliconSector
The Factory Secured Silicon Sector is always protected when shipped from the factory and has
the Factory Indicator Bit (DQ7) permanently set to a 1. This prevents cloning of a factory locked
part and ensures the security of the ESN and customer code once the product is shipped to the
field.
These devices are available pre programmed with one of the following:
„ A random, 8 Word secure ESN only within the Factory Secured Silicon Sector
„ Customer code within the Customer Secured Silicon Sector through the SpansionTM programming service.
„ Both a random, secure ESN and customer code through the Spansion programming service.
Customers may opt to have their code programmed through the Spansion programming services.
Spansion programs the customer's code, with or without the random ESN. The devices are then
shipped from the Spansion factory with the Factory Secured Silicon Sector and Customer Secured
Silicon Sector permanently locked. Contact your local representative for details on using Spansion
programming services.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
61
A d v a n c e
11.2
I n f o r m a t i o n
Customer Secured Silicon Sector
The Customer Secured Silicon Sector is typically shipped unprotected (DQ6 set to 0), allowing
customers to utilize that sector in any manner they choose. If the security feature is not required,
the Customer Secured Silicon Sector can be treated as an additional Flash memory space.
Please note the following:
„ Once the Customer Secured Silicon Sector area is protected, the Customer Indicator Bit is
permanently set to 1.
„ The Customer Secured Silicon Sector can be read any number of times, but can be programmed and locked only once. The Customer Secured Silicon Sector lock must be used with
caution as once locked, there is no procedure available for unlocking the Customer Secured
Silicon Sector area and none of the bits in the Customer Secured Silicon Sector memory space
can be modified in any way.
„ The accelerated programming (ACC) and unlock bypass functions are not available when programming the Customer Secured Silicon Sector, but reading in Banks 1 through 15 is available.
„ Once the Customer Secured Silicon Sector is locked and verified, the system must write the
Exit Secured Silicon Sector Region command sequence which return the device to the memory array at sector 0.
11.3 Secured Silicon Sector Entry and Secured Silicon Sector Exit
Command Sequences
The system can access the Secured Silicon Sector region by issuing the three-cycle Enter Secured
Silicon Sector command sequence. The device continues to access the Secured Silicon Sector region until the system issues the four-cycle Exit Secured Silicon Sector command sequence.
See Command Definition Table [Secured Silicon Sector Command Table, Appendix
Table 13.1 for address and data requirements for both command sequences.
The Secured Silicon Sector Entry Command allows the following commands to be executed
„ Read customer and factory Secured Silicon areas
„ Program the customer Secured Silicon Sector
After the system has written the Enter Secured Silicon Sector command sequence, it may read
the Secured Silicon Sector by using the addresses normally occupied by sector SA0 within the
memory array. This mode of operation continues until the system issues the Exit Secured Silicon
Sector command sequence, or until power is removed from the device.
62
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Software Functions and Sample Code
The following are C functions and source code examples of using the Secured Silicon Sector
Entry, Program, and exit commands. Refer to the Spansion Low Level Driver User’s Guide
(available soon on www.amd.com and www.fujitsu.com) for general information on Spansion
Flash memory software development guidelines.
Table 11.2
Secured Silicon Sector Entry
(LLD Function = lld_SecSiSectorEntryCmd)
Cycle
Operation
Byte Address
Word Address
Data
Unlock Cycle 1
Write
Base + AAAh
Base + 555h
00AAh
Unlock Cycle 2
Write
Base + 554h
Base + 2AAh
0055h
Entry Cycle
Write
Base + AAAh
Base + 555h
0088h
Note: Base = Base Address.
/* Example: SecSi Sector
*( (UINT16 *)base_addr
*( (UINT16 *)base_addr
*( (UINT16 *)base_addr
Entry Command */
+ 0x555 ) = 0x00AA;
+ 0x2AA ) = 0x0055;
+ 0x555 ) = 0x0088;
Table 11.3
/* write unlock cycle 1
/* write unlock cycle 2
/* write Secsi Sector Entry Cmd
*/
*/
*/
Secured Silicon Sector Program
(LLD Function = lld_ProgramCmd)
Cycle
Operation
Byte Address
Word Address
Data
Unlock Cycle 1
Write
Base + AAAh
Base + 555h
00AAh
Unlock Cycle 2
Write
Base + 554h
Base + 2AAh
0055h
Program Setup
Write
Base + AAAh
Base + 555h
00A0h
Program
Write
Word Address
Word Address
Data Word
Note: Base = Base Address.
/* Once in the SecSi Sector mode, you program */
/* words using the programming algorithm.
*/
Table 11.4
Secured Silicon Sector Exit
(LLD Function = lld_SecSiSectorExitCmd)
Cycle
Operation
Byte Address
Word Address
Data
Unlock Cycle 1
Write
Base + AAAh
Base + 555h
00AAh
Unlock Cycle 2
Write
Base + 554h
Base + 2AAh
0055h
Exit Cycle
Write
Base + AAAh
Base + 555h
0090h
Note: Base = Base Address.
/* Example: SecSi Sector
*( (UINT16 *)base_addr
*( (UINT16 *)base_addr
*( (UINT16 *)base_addr
*( (UINT16 *)base_addr
March 14, 2005 S70WS512N00_00_A0
Exit Command */
+ 0x555 ) = 0x00AA;
+ 0x2AA ) = 0x0055;
+ 0x555 ) = 0x0090;
+ 0x000 ) = 0x0000;
/*
/*
/*
/*
write
write
write
write
S70WS512N00 Based MCPs
unlock cycle
unlock cycle
SecSi Sector
SecSi Sector
1
2
Exit cycle 3
Exit cycle 4
*/
*/
*/
*/
63
A d v a n c e
I n f o r m a t i o n
12 Electrical Specifications
12.1
Absolute Maximum Ratings
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Ambient Temperature
with Power Applied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to +125°C
Voltage with Respect to Ground:
All Inputs and I/Os except
as noted below (Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VIO + 0.5 V
VCC (Note 1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–0.5 V to +2.5 V
VIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–0.5 V to +2.5 V
ACC (Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–0.5 V to +9.5 V
Output Short Circuit Current (Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mA
Notes:
1.
2.
3.
4.
Minimum DC voltage on input or I/Os is –0.5 V. During voltage transitions, inputs or I/Os may undershoot VSS to –2.0 V
for periods of up to 20 ns. See Figure 12.1. Maximum DC voltage on input or I/Os is VCC + 0.5 V. During voltage
transitions outputs may overshoot to VCC + 2.0 V for periods up to 20 ns. See Figure 12.2.
Minimum DC input voltage on pin ACC is -0.5V. During voltage transitions, ACC may overshoot VSS to –2.0 V for periods
of up to 20 ns. See Figure 12.1. Maximum DC voltage on pin ACC is +9.5 V, which may overshoot to 10.5 V for periods
up to 20 ns.
No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than
one second.
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a
stress rating only; functional operation of the device at these or any other conditions above those indicated in the
operational sections of this data sheet is not implied. Exposure of the device to absolute maximum rating conditions for
extended periods may affect device reliability.
20 ns
20 ns
20 ns
VCC
+2.0 V
VCC
+0.5 V
+0.8 V
–0.5 V
–2.0 V
1.0 V
20 ns
20 ns
Figure 12.1 Maximum Negative
Overshoot Waveform
20 ns
Figure 12.2 Maximum Positive
Overshoot Waveform
Note: The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document is
Preliminary for the S29W256N.
12.2
Operating Ranges
Wireless (W) Devices
Ambient Temperature (TA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –25°C to +85°C
Industrial (I) Devices
Ambient Temperature (TA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
Supply Voltages
VCC Supply Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+1.70 V to +1.95 V
VIO Supply Voltages: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +1.70 V to +1.95 V
(Contact local sales office for VIO = 1.35 to +1.70 V.)
Note: Operating ranges define those limits between which the device functionality is guaranteed.
64
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
12.3
I n f o r m a t i o n
Test Conditions
Device
Under
Test
CL
Figure 12.3
Table 12.1
Test Setup
Test Specifications
Test Condition
All Speed Options
Unit
30
pF
Output Load Capacitance, CL
(including jig capacitance)
3.0 @ 54, 66 MHz
Input Rise and Fall Times
ns
2.5 @ 80 MHz
Input Pulse Levels
0.0–VIO
V
Input timing measurement reference levels
VIO/2
V
Output timing measurement reference levels
VIO/2
V
Note: The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
12.4
Key to Switching Waveforms
Waveform
Inputs
Outputs
Steady
Changing from H to L
Changing from L to H
Don’t Care, Any Change Permitted
Changing, State Unknown
Does Not Apply
Center Line is High Impedance State
(High Z)
Note: The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
12.5
Switching Waveforms
All Inputs and Outputs
VIO
Input
VIO/2
Measurement Level
VIO/2
Output
0.0 V
Figure 12.4
March 14, 2005 S70WS512N00_00_A0
Input Waveforms and Measurement Levels
S70WS512N00 Based MCPs
65
A d v a n c e
12.6
I n f o r m a t i o n
VCC Power-up
Parameter
Description
Test Setup
Speed
Unit
tVCS
VCC Setup Time
Min
1
ms
Notes:
1.
2.
3.
VCC >= VIO - 100mV and VCC ramp rate is > 1V / 100µs
VCC ramp rate <1V / 100µs, a Hardware Reset is required.
The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
tVCS
VCC
VIO
RESET#
Figure 12.5
66
VCC Power-up Diagram
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
12.7
I n f o r m a t i o n
DC Characteristics
(CMOS Compatible)
Parameter
Max
Unit
ILI
Input Load Current
Description (Notes)
VIN = VSS to VCC, VCC = VCCmax
Test Conditions (Notes 1, 2, 9)
±1
µA
ILO
Output Leakage Current (3)
VOUT = VSS to VCC, VCC = VCCmax
±1
µA
CE# = VIL, OE# = VIH, WE#
= VIH, burst length = 8
CE# = VIL, OE# = VIH, WE#
= VIH, burst length = 16
ICCB
VCC Active burst Read Current
CE# = VIL, OE# = VIH, WE#
= VIH, burst length = 32
CE# = VIL, OE# = VIH, WE#
= VIH, burst length =
Continuous
IIO1
VIO Non-active Output
OE# = VIH
ICC1
VCC Active Asynchronous
Read Current (4)
CE# = VIL, OE# = VIH, WE#
= VIH
Min
Typ
54 MHz
27
54
mA
66 MHz
28
60
mA
80 MHz
30
66
mA
54 MHz
28
48
mA
66 MHz
30
54
mA
80 MHz
32
60
mA
54 MHz
29
42
mA
66 MHz
32
48
mA
80 MHz
34
54
mA
54 MHz
32
36
mA
66 MHz
35
42
mA
80 MHz
38
48
mA
20
30
µA
10 MHz
27
36
mA
5 MHz
13
18
mA
1 MHz
3
4
mA
1
5
µA
VCC Active Write Current (5)
CE# = VIL, OE# = VIH, ACC
= VIH
VACC
VCC
19
52.5
mA
ICC3
VCC Standby Current (6, 7)
CE# = RESET# =
VCC ± 0.2 V
VACC
1
5
µA
VCC
20
40
µA
ICC4
VCC Reset Current (7)
RESET# = VIL, CLK = VIL
70
150
µA
ICC5
VCC Active Current
(Read While Write) (7)
CE# = VIL, OE# = VIH, ACC = VIH @
5 MHz
50
60
mA
ICC6
VCC Sleep Current (7)
CE# = VIL, OE# = VIH
2
40
µA
IACC
Accelerated Program Current (8)
CE# = VIL, OE# = VIH,
VACC = 9.5 V
VACC
6
20
mA
VCC
14
20
mA
VIL
Input Low Voltage
VIO = 1.8 V
–0.5
0.4
V
VIH
Input High Voltage
VIO = 1.8 V
VIO – 0.4
VIO + 0.4
V
0.1
V
ICC2
VOL
Output Low Voltage
IOL = 100 µA, VCC = VCC min = VIO
VOH
Output High Voltage
IOH = –100 µA, VCC = VCC min = VIO
VHH
Voltage for Accelerated Program
8.5
9.5
V
VLKO
Low VCC Lock-out Voltage
1.0
1.4
V
VIO – 0.1
V
Notes:
1.
2.
3.
4.
5.
6.
Maximum ICC specifications are tested with VCC = VCCmax.
VCC= VIO.
CE# must be set high when measuring the RDY pin.
The ICC current listed is typically less than 3 mA/MHz, with OE# at VIH.
ICC active while Embedded Erase or Embedded Program is in progress.
Device enters automatic sleep mode when addresses are stable for tACC + 20 ns. Typical sleep mode current is equal to
ICC3.
7. VIH = VCC ± 0.2 V and VIL > –0.1 V.
8. Total current during accelerated programming is the sum of VACC and VCC currents.
9. VACC = VHH on ACC input.
10. The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
67
A d v a n c e
12.8
I n f o r m a t i o n
AC Characteristics
12.8.1
CLK Characterization
Parameter
Description
54 MHz
66 MHz
80 MHz
Unit
fCLK
CLK Frequency
Max
54
66
80
MHz
tCLK
CLK Period
Min
18.5
15.1
12.5
ns
tCH
CLK High Time
tCL
CLK Low Time
Min
7.4
6.1
5.0
ns
tCR
CLK Rise Time
tCF
CLK Fall Time
Max
3
3
2.5
ns
Note: The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
tCLK
tCH
CLK
tCL
tCF
tCR
Figure 12.6 CLK Characterization
12.8.2
Synchronous/Burst Read
Parameter
JEDEC
Standard
Description
54 MHz
66 MHz
11.2
tIACC
Latency
Max
tBACC
Burst Access Time Valid Clock to Output Delay
Max
13.5
80 MHz
80
Unit
ns
9
ns
tACS
Address Setup Time to CLK (Note 1)
Min
5
4
ns
tACH
Address Hold Time from CLK (Note 1)
Min
7
6
ns
tBDH
Data Hold Time from Next Clock Cycle
Min
4
tCR
Chip Enable to RDY Valid
Max
13.5
13.5
3
11.2
ns
9
11.2
ns
tOE
Output Enable to Output Valid
Max
tCEZ
Chip Enable to High Z (Note 2)
Max
10
ns
ns
tOEZ
Output Enable to High Z (Note 2)
Max
10
ns
tCES
CE# Setup Time to CLK
Min
4
ns
tRDYS
RDY Setup Time to CLK
Min
5
4
3.5
ns
tRACC
Ready Access Time from CLK
Max
13.5
11.2
9
ns
tCAS
CE# Setup Time to AVD#
Min
0
ns
tAVC
AVD# Low to CLK
Min
4
ns
tAVD
AVD# Pulse
Min
8
ns
tAOE
AVD Low to OE# Low
Max
38.4
ns
Notes:
1.
2.
3.
68
Addresses are latched on the first rising edge of CLK.
Not 100% tested.
The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
12.8.3
I n f o r m a t i o n
Timing Diagrams
5 cycles for initial access shown.
tCES
tCEZ
18.5 ns typ. (54 MHz)
CE#
1
2
3
4
5
6
7
CLK
tAVC
AVD#
tAVD
tACS
Addresses
Aa
tBACC
tACH
Hi-Z
Data (n)
tIACC
Da
tAOE
Da + 1
Da + 2
Da + 3
Da + n
tOEZ
tBDH
OE#
tOE
RDY (n)
tRACC
Hi-Z
Hi-Z
tCR
tRDYS
Hi-Z
Data (n + 1)
Da
RDY (n + 1)
Da + 1
Da + 2
Da + 2
Da + n
Hi-Z
Hi-Z
Hi-Z
Data (n + 2)
Da
RDY (n + 2)
Da + 1
Da + 1
Da + 1
Da + n
Hi-Z
Hi-Z
Hi-Z
Data (n + 3)
Da
RDY (n + 3)
Da
Da
Hi-Z
Da
Da + n
Hi-Z
Notes:
1.
2.
3.
Figure shows total number of wait states set to five cycles. The total number of wait states can be programmed from two
cycles to seven cycles.
If any burst address occurs at address + 1 , address + 2, or address + 3, additional clock delay cycles are inserted, and
are indicated by RDY.
The device is in synchronous mode.
Figure 12.7
March 14, 2005 S70WS512N00_00_A0
CLK Synchronous Burst Mode Read
S70WS512N00 Based MCPs
69
A d v a n c e
I n f o r m a t i o n
7 cycles for initial access shown.
tCES
CE#
1
2
3
4
5
6
7
CLK
tAVC
AVD#
tAVD
tACS
Addresses
Ac
tBACC
tACH
Data
tIACC
DC
DD
DE
DF
DB
D8
tBDH
tAOE
OE#
tCR
tRACC
tRACC
tOE
Hi-Z
RDY
tRDYS
Notes:
1.
2.
3.
4.
Figure shows total number of wait states set to seven cycles. The total number of wait states can be programmed from
two cycles to seven cycles.
If any burst address occurs at address + 1 , address + 2, or address + 3, additional clock delay cycles are inserted, and
are indicated by RDY.
The device is in synchronous mode with wrap around.
D8–DF in data waveform indicate the order of data within a given 8-word address range, from lowest to highest. Starting
address in figure is the 4th address in range (0-F).
Figure 12.8
tCES
8-word Linear Burst with Wrap Around
7 cycles for initial access shown.
CE#
1
2
3
4
5
6
7
CLK
tAVC
AVD#
tAVD
tACS
Addresses
Ac
tBACC
tACH
Data
tIACC
tAOE
DC
DD
DE
DF
D10
D13
tBDH
OE#
tCR
RDY
tOE
tRACC
tRACC
Hi-Z
tRDYS
Notes:
1.
2.
3.
4.
Figure shows total number of wait states set to seven cycles. The total number of wait states can be programmed from
two cycles to seven cycles. Clock is set for active rising edge.
If any burst address occurs at address + 1 , address + 2, or address + 3, additional clock delay cycles are inserted, and
are indicated by RDY.
The device is in asynchronous mode with out wrap around.
DC–D13 in data waveform indicate the order of data within a given 8-word address range, from lowest to highest.
Starting address in figure is the 1st address in range (c-13).
Figure 12.9 8-word Linear Burst without Wrap Around
70
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
tCES
tCEZ
6 wait cycles for initial access shown.
CE#
1
2
3
4
5
6
CLK
tAVC
AVD#
tAVD
tACS
Addresses
Aa
tBACC
tACH
Hi-Z
Data
tIACC
Da
Da+2
Da+3
Da + n
tBDH
tAOE
tOEZ
tRACC
OE#
tCR
RDY
Da+1
tOE
Hi-Z
Hi-Z
tRDYS
Notes:
1.
2.
Figure assumes 6 wait states for initial access and synchronous read.
The Set Configuration Register command sequence has been written with CR8=0; device outputs RDY one cycle before
valid data.
Figure 12.10
12.8.4
Linear Burst with RDY Set One Cycle Before Data
AC Characteristics—Asynchronous Read
Parameter
JEDEC
Description
Standard
54 MHz
66 MHz
80 MHz
Unit
tCE
Access Time from CE# Low
Max
80
ns
tACC
Asynchronous Access Time
Max
80
ns
tAVDP
AVD# Low Time
Min
8
ns
tAAVDS
Address Setup Time to Rising Edge of AVD#
Min
4
ns
tAAVDH
Address Hold Time from Rising Edge of AVD#
Min
tOE
Output Enable to Output Valid
Max
13.5
ns
tOEH
Output Enable Hold Time
Read
Min
0
ns
Data# Polling
Min
10
ns
tOEZ
Output Enable to High Z (see Note)
Max
10
ns
tCAS
CE# Setup Time to AVD#
Min
0
ns
7
6
ns
Notes:
1.
2.
Not 100% tested.
The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
71
A d v a n c e
I n f o r m a t i o n
CE#
tOE
OE#
tOEH
WE#
tCE
tOEZ
Data
Valid RD
tACC
RA
Addresses
tAAVDH
tCAS
AVD#
tAVDP
tAAVDS
Note: RA = Read Address, RD = Read Data.
Figure 12.11 Asynchronous Mode Read
12.8.5
Hardware Reset (RESET#)
Parameter
JEDEC
Std.
Description
All Speed Options
Unit
tRP
RESET# Pulse Width
Min
30
µs
tRH
Reset High Time Before Read (See Note)
Min
200
ns
Notes:
1.
2.
Not 100% tested.
The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
CE#, OE#
tRH
RESET#
tRP
Figure 12.12
72
Reset Timings
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
12.8.6
I n f o r m a t i o n
Erase/Program Timing
Parameter
JEDEC
Standard
tAVAV
tWC
tAVWL
tWLAX
tAS
tAH
Description
54 MHz
Write Cycle Time (Note 1)
Address Setup Time (Notes 2, 3)
Address Hold Time (Notes 2, 3)
Min
Synchronous
Asynchronous
Synchronous
Asynchronous
Min
66 MHz
80 MHz
80
ns
5
ns
0
ns
9
Min
ns
20
Min
Unit
tAVDP
AVD# Low Time
8
tDVWH
tDS
Data Setup Time
Min
tWHDX
tDH
Data Hold Time
Min
0
ns
tGHWL
tGHWL
45
ns
20
ns
Read Recovery Time Before Write
Min
0
ns
tCAS
CE# Setup Time to AVD#
Min
0
ns
tWHEH
tCH
CE# Hold Time
Min
0
ns
tWLWH
tWP
Write Pulse Width
Min
30
ns
tWHWL
tWPH
Write Pulse Width High
Min
20
ns
tSR/W
Latency Between Read and Write Operations
Min
0
ns
tELWL
tVID
VACC Rise and Fall Time
Min
500
ns
tVIDS
VACC Setup Time (During Accelerated Programming)
Min
1
µs
tVCS
VCC Setup Time
Min
50
µs
tCS
CE# Setup Time to WE#
Min
5
ns
tAVSW
AVD# Setup Time to WE#
Min
5
ns
tAVHW
AVD# Hold Time to WE#
Min
5
ns
tAVSC
AVD# Setup Time to CLK
Min
5
ns
tAVHC
AVD# Hold Time to CLK
Min
5
ns
tCSW
Clock Setup Time to WE#
Min
5
ns
tWEP
Noise Pulse Margin on WE#
Max
3
ns
tSEA
Sector Erase Accept Time-out
Max
50
µs
tESL
Erase Suspend Latency
Max
20
µs
tPSL
Program Suspend Latency
Max
20
µs
tASP
Toggle Time During Sector Protection
Typ
100
µs
tPSP
Toggle Time During Programming Within a Protected Sector
Typ
1
µs
Notes:
1.
2.
3.
4.
5.
6.
Not 100% tested.
Asynchronous read mode allows Asynchronous program operation only. Synchronous read mode allows both
Asynchronous and Synchronous program operation.
In asynchronous program operation timing, addresses are latched on the falling edge of WE#. In synchronous program
operation timing, addresses are latched on the rising edge of CLK.
See the Erase and Programming Performance section for more information.
Does not include the preprogramming time.
The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
73
A d v a n c e
I n f o r m a t i o n
Erase Command Sequence (last two cycles)
VIH
Read Status Data
CLK
VIL
tAVDP
AVD#
tAH
tAS
Addresses
VA
SA
2AAh
555h for
chip erase
Data
55h
VA
10h for
chip erase
In
Progress
30h
Complete
tDS
tDH
CE#
tCH
OE#
tWP
WE#
tWHWH2
tCS
tVCS
tWPH
tWC
VCC
Figure 12.13
74
Chip/Sector Erase Operation Timings
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Program Command Sequence (last two cycles)
Read Status Data
VIH
CLK
VIL
tAVSW
tAVHW
tAVDP
AVD
tAS
tAH
Addresses
555h
VA
PA
Data
A0h
VA
In
Progress
PD
Complete
tDS
tCAS
tDH
CE#
tCH
OE#
tWP
WE#
tWHWH1
tCS
tWPH
tWC
tVCS
VCC
Notes:
1.
2.
3.
4.
5.
PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
In progress and complete refer to status of program operation.
A23–A14 for the WS256N (A22–A14 for the WS128N, A21–A14 for the WS064N) are don’t care during command
sequence unlock cycles.
CLK can be either VIL or VIH.
The Asynchronous programming operation is independent of the Set Device Read Mode bit in the Configuration Register.
Figure 12.14
March 14, 2005 S70WS512N00_00_A0
Asynchronous Program Operation Timings
S70WS512N00 Based MCPs
75
A d v a n c e
I n f o r m a t i o n
Program Command Sequence (last two cycles)
Read Status Data
tAVCH
CLK
tAS
tAH
tAVSC
AVD#
tAVDP
Addresses
VA
PA
555h
Data
In
Progress
PD
A0h
VA
Complete
tDS
tDH
tCAS
CE#
OE#
tCH
tCSW
tWP
WE#
tWHWH1
tWPH
tWC
tVCS
VCC
Notes:
1.
2.
3.
4.
5.
6.
PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
In progress and complete refer to status of program operation.
A23–A14 for the WS256N (A22–A14 for the WS128N, A21–A14 for the WS064N) are don’t care during command
sequence unlock cycles.
Addresses are latched on the first rising edge of CLK.
Either CE# or AVD# is required to go from low to high in between programming command sequences.
The Synchronous programming operation is dependent of the Set Device Read Mode bit in the Configuration Register.
The Configuration Register must be set to the Synchronous Read Mode.
Figure 12.15
Synchronous Program Operation Timings
CE#
AVD#
WE#
Addresses
PA
Data
Don't Care
OE#
tVIDS
ACC
A0h
Don't Care
PD
Don't Care
VID
tVID
VIL or VIH
Note: Use setup and hold times from conventional program operation.
Figure 12.16
76
Accelerated Unlock Bypass Programming Timing
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
AVD#
tCEZ
tCE
CE#
tCH
tOEZ
tOE
OE#
tOEH
WE#
tACC
Addresses
VA
High Z
VA
High Z
Status Data
Data
Status Data
Notes:
1.
2.
Status reads in figure are shown as asynchronous.
VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is
completeData# Polling outputs true data.
Figure 12.17
Data# Polling Timings (During Embedded Algorithm)
AVD#
tCEZ
tCE
CE#
tCH
tOEZ
tOE
OE#
tOEH
WE#
tACC
Addresses
VA
High Z
VA
High Z
Data
Status Data
Status Data
Notes:
1.
2.
Status reads in figure are shown as asynchronous.
VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is
complete, .
Figure 12.18
March 14, 2005 S70WS512N00_00_A0
Toggle Bit Timings (During Embedded Algorithm)
S70WS512N00 Based MCPs
77
A d v a n c e
I n f o r m a t i o n
CE#
CLK
AVD#
Addresses
VA
VA
OE#
tIACC
tIACC
Data
Status Data
Status Data
RDY
Notes:
1.
2.
3.
The timings are similar to synchronous read timings.
VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is
complete, .
RDY is active with data (D8 = 1 in the Configuration Register). When D8 = 0 in the Configuration Register, RDY is active
one clock cycle before data.
Figure 12.19
Enter
Embedded
Erasing
WE#
Synchronous Data Polling Timings/Toggle Bit Timings
Erase
Suspend
Erase
Enter Erase
Suspend Program
Erase Suspend
Read
Erase
Suspend
Program
Erase
Resume
Erase Suspend
Read
Erase
Erase
Complete
DQ6
DQ2
Note: DQ2 toggles only when read at an address within an erase-suspended sector. The system may use OE# or CE# to
toggle DQ2 and DQ6
Figure 12.20
78
DQ2 vs. DQ6
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Address boundary occurs every 128 words, beginning at address
00007Fh: (0000FFh, 00017Fh, etc.) Address 000000h is also a boundary crossing.
C124
C125
C126
7C
7D
7E
C127
C127
C128
C129
7F
7F
80
81
C130
C131
CLK
Address (hex)
AVD#
83
(stays high)
tRACC
tRACC
RDY(1)
latency
tRACC
RDY(2)
tRACC
latency
Data
OE#,
CE#
82
D124
D125
D126
D127
D128
D129
D130
(stays low)
Notes:
1.
2.
3.
4.
5.
RDY(1) active with data (D8 = 1 in the Configuration Register).
RDY(2) active one clock cycle before data (D8 = 0 in the Configuration Register).
Cxx indicates the clock that triggers Dxx on the outputs; for example, C60 triggers D60.
Figure shows the device not crossing a bank in the process of performing an erase or program.
RDY does not go low and no additional wait states are required if the Burst frequency is <=66 MHz and the Boundary
Crossing bit (D14) in the Configuration Register is set to 0
Figure 12.21
March 14, 2005 S70WS512N00_00_A0
Latency with Boundary Crossing when Frequency > 66 MHz
S70WS512N00 Based MCPs
79
A d v a n c e
I n f o r m a t i o n
Address boundary occurs every 128 words, beginning at address
00007Fh: (0000FFh, 00017Fh, etc.) Address 000000h is also a boundary crossing.
C124
C125
C126
7C
7D
7E
C127
C127
CLK
Address (hex)
AVD#
7F
7F
(stays high)
tRACC
tRACC
RDY(1)
latency
tRACC
RDY(2)
latency
Data
OE#,
CE#
tRACC
D124
D125
D126
D127
Read Status
(stays low)
Notes:
1.
2.
3.
4.
5.
RDY(1) active with data (D8 = 1 in the Configuration Register).
RDY(2) active one clock cycle before data (D8 = 0 in the Configuration Register).
Cxx indicates the clock that triggers Dxx on the outputs; for example, C60 triggers D60.
Figure shows the device crossing a bank in the process of performing an erase or program.
RDY does not go low and no additional wait states are required if the Burst frequency is < 66 MHz and the Boundary
Crossing bit (D14) in the Configuration Register is set to 0.
Figure 12.22
80
Latency with Boundary Crossing into Program/Erase Bank
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Data
D0
D1
Rising edge of next clock cycle
following last wait state triggers
next burst data
AVD#
total number of clock cycles
following addresses being latched
OE#
1
2
3
0
1
4
5
6
7
3
4
5
CLK
2
number of clock cycles
programmed
Wait State Configuration Register Setup:
D13,
D13,
D13,
D13,
D13,
D13,
D13,
D13,
D12,
D12,
D12,
D12,
D12,
D12,
D12,
D12,
D11
D11
D11
D11
D11
D11
D11
D11
=
=
=
=
=
=
=
=
111
110
101
100
011
010
001
000
⇒ Reserved
⇒ Reserved
⇒ 5 programmed, 7 total
⇒ 4 programmed, 6 total
⇒ 3 programmed, 5 total
⇒ 2 programmed, 4 total
⇒ 1 programmed, 3 total
⇒ 0 programmed, 2 total
Note: 6.Figure assumes address D0 is not at an address boundary, and wait state is set to 101
Figure 12.23 Example of Wait State Insertion
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
81
A d v a n c e
Last Cycle in
Program or
Sector Erase
Command Sequence
I n f o r m a t i o n
Read status (at least two cycles) in same bank
and/or array data from other bank
tWC
tRC
Begin another
write or program
command sequence
tRC
tWC
CE#
OE#
tOE
tOEH
tGHWL
WE#
tWPH
tWP
tDS
Data
tOEZ
tACC
tOEH
tDH
RD
PD/30h
RD
AAh
tSR/W
Addresses
PA/SA
RA
RA
555h
tAS
AVD#
tAH
Note: Breakpoints in waveforms indicate that system may alternately read array data from the non-busy bank while checking the status of the program or erase operation in the busy bank. The system should read status twice to ensure
valid information.
Figure 12.24 Back-to-Back Read/Write Cycle Timings
82
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
12.8.7
I n f o r m a t i o n
Erase and Programming Performance
Parameter
Sector Erase Time
Typ (Note 1)
Max (Note 2)
64 Kword
VCC
0.6
3.5
16 Kword
VCC
<0.15
2
153.6 (WS256N)
308 (WS256N)
154 (WS128N)
78 (WS064N)
VCC
77.4 (WS128N)
39.3 (WS064N)
Chip Erase Time
130.6 (WS256N)
33.4 (WS064N)
Single Word Programming Time
(Note 8)
VCC
40
400
ACC
24
240
Effective Word Programming Time
utilizing Program Write Buffer
VCC
9.4
94
ACC
6
60
Total 32-Word Buffer Programming
Time
VCC
300
3000
ACC
192
1920
157.3 (WS256N)
39.3 (WS064N)
314.6 (WS256N)
157.3 (WS128N)
78.6 (WS064N)
100.7 (WS256N)
50.3 (WS128N)
25.2 (WS064N)
201.3 (WS256N)
100.7 (WS128N)
50.3 (WS064N)
VCC
Chip Programming Time (Note 3)
ACC
65.8 (WS128N)
78.6 (WS128N)
Comments
s
s
262 (WS256N)
132 (WS128N)
66 (WS064N)
ACC
Unit
Excludes 00h
programming prior
to erasure (Note 4)
µs
µs
µs
s
Excludes system
level overhead
(Note 5)
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Typical program and erase times assume the following conditions: 25°C, 1.8 V VCC, 10,000 cycles; checkerboard data
pattern.
Under worst case conditions of 90°C, VCC = 1.70 V, 100,000 cycles.
Typical chip programming time is considerably less than the maximum chip programming time listed, and is based on
utilizing the Write Buffer.
In the pre-programming step of the Embedded Erase algorithm, all words are programmed to 00h before erasure.
System-level overhead is the time required to execute the two- or four-bus-cycle sequence for the program command.
See the Appendix for further information about command definitions.
Contact the local sales office for minimum cycling endurance values in specific applications and operating conditions.
Refer to Application Note Erase Suspend/Resume Timing for more details.
Word programming specification is based upon a single word programming operation not utilizing the write buffer.
The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
83
A d v a n c e
12.8.8
I n f o r m a t i o n
BGA Ball Capacitance
Parameter Symbol
Parameter Description
Test Setup
Typ.
Max
Unit
CIN
Input Capacitance
VIN = 0
5.3
6.3
pF
COUT
Output Capacitance
VOUT = 0
5.8
6.8
pF
CIN2
Control Pin Capacitance
VIN = 0
6.3
7.3
pF
Notes:
1.
2.
3.
84
Sampled, not 100% tested.
Test conditions TA = 25°C; f = 1.0 MHz.
The content in this document is Advance information for the S29WS064N and S29WS128N. Content in this document
is Preliminary for the S29W256N.
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
13 Appendix
This section contains information relating to software control or interfacing with the Flash device.
For additional information and assistance regarding software, see the Additional Resources on
page 18, or explore the Web at www.amd.com and www.fujitsu.com.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
85
A d v a n c e
Autoselect (8)
Command Sequence
(Notes)
Asynchronous Read (6)
Reset (7)
Manufacturer ID
Device ID (9)
Cycles
Table 13.1
1
1
4
6
First
Addr
Data
RA
RD
XXX
F0
555
AA
555
AA
I n f o r m a t i o n
Memory Array Commands
Second
Addr
Data
Bus Cycles (Notes 1–5)
Third
Fourth
Addr
Data
Addr
Data
2AA
2AA
55
55
[BA]555
[BA]555
90
90
[BA]X00
[BA]X01
0001
227E
Data
BA+X0F
2200
PD
WC
PA
PD
WBL
PD
555
555
AA
AA
2AA
2AA
55
55
555
SA
10
30
X00
X00
CR
CR
88
A0
PA
PD
90
XXX
00
555
AA
2AA
55
[BA]555
90
[BA]X03
Data
Program
Write to Buffer (11)
Program Buffer to Flash
Write to Buffer Abort Reset (12)
Chip Erase
Sector Erase
Erase/Program Suspend (13)
Erase/Program Resume (14)
Set Configuration Register (18)
Read Configuration Register
CFI Query (15)
Entry
Program (16)
CFI (16)
4
6
1
3
6
6
1
1
4
4
1
3
2
1
555
555
SA
555
555
555
BA
BA
555
555
[BA]555
555
XXX
XXX
AA
AA
29
AA
AA
AA
B0
30
AA
AA
98
AA
A0
98
2AA
2AA
55
55
555
PA
A0
25
PA
PA
2AA
2AA
2AA
55
55
55
555
555
555
F0
80
80
2AA
2AA
55
55
555
555
D0
C6
2AA
PA
55
PD
555
20
Reset
2
XXX
90
XXX
00
Entry
Program (17)
Read (17)
3
4
1
555
555
00
AA
AA
Data
2AA
2AA
55
55
555
555
Exit (17)
4
555
AA
2AA
55
555
Secured Silicon Sector
Unlock Bypass
Mode
4
Notes:
1. See Table 8.1 for description of bus operations.
2. All values are in hexadecimal.
3. Shaded cells indicate read cycles.
4. Address and data bits not specified in table, legend, or notes are
don’t cares (each hex digit implies 4 bits of data).
5. Writing incorrect address and data values or writing them in the
improper sequence may place the device in an unknown state.
The system must write the reset command to return the device
to reading array data.
6. No unlock or command cycles required when bank is reading
array data.
7. Reset command is required to return to reading array data (or to
the erase-suspend-read mode if previously in Erase Suspend)
when a bank is in the autoselect mode, or if DQ5 goes high
(while the bank is providing status information) or performing
sector lock/unlock.
8. The system must provide the bank address. See Autoselect
section for more information.
9. Data in cycle 5 is 2230 (WS256N), 2232 (WS064N), or 2231
(WS128N).
10. See Table 8.9 for indicator bit values.
86
Sixth
Addr
Data
BA+X0E
Indicator Bits (10)
Legend:
X = Don’t care.
RA = Read Address.
RD = Read Data.
PA = Program Address. Addresses latch on the rising edge of the
AVD# pulse or active edge of CLK, whichever occurs first.
PD = Program Data. Data latches on the rising edge of WE# or CE#
pulse, whichever occurs first.
Fifth
Addr
Data
SA = Sector Address. WS256N = A23–A14; WS128N = A22–A14;
WS064N = A21–A14.
BA = Bank Address. WS256N = A23–A20; WS128N = A22–A20;
WS064N = A21–A18.
CR = Configuration Register data bits D15–D0.
WBL = Write Buffer Location. Address must be within the same write
buffer page as PA.
WC = Word Count. Number of write buffer locations to load minus 1.
11. Total number of cycles in the command sequence is determined
by the number of words written to the write buffer.
12. Command sequence resets device for next command after writeto-buffer operation.
13. System may read and program in non-erasing sectors, or enter
the autoselect mode, when in the Erase Suspend mode. The
Erase Suspend command is valid only during a sector erase
operation, and requires the bank address.
14. Erase Resume command is valid only during the Erase Suspend
mode, and requires the bank address.
15. Command is valid when device is ready to read array data or
when device is in autoselect mode. Address equals 55h on all
future devices, but 555h for WS256N/128N/064N.
16. Requires Entry command sequence prior to execution. Unlock
Bypass Reset command is required to return to reading array
data.
17. Requires Entry command sequence prior to execution. Secured
Silicon Sector Exit Reset command is required to exit this mode;
device may otherwise be placed in an unknown state.
18. Requires reset command to configure the Configuration Register.
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Command Sequence
(Notes)
Command Set Entry (5)
Lock
Program (6, 12)
Register
Read (6)
Bits
Command Set Exit (7)
Command Set Entry (5)
Program [0-3] (8)
Password
Read (9)
Protection
Unlock
Command Set Exit (7)
Command Set Entry (5)
PPB Program (10)
Non-Volatile
Sector
All PPB Erase (10, 11)
Protection (PPB) PPB Status Read
Command Set Exit (7)
Global
Command Set Entry (5)
Volatile Sector PPB Lock Bit Set
Protection
PPB Lock Bit Status Read
Freeze
Command Set Exit (7)
(PPB Lock)
Volatile Sector
Protection
(DYB)
Command Set Entry (5)
DYB Set
DYB Clear
DYB Status Read
Command Set Exit (7)
Cycles
Table 13.2
3
2
1
2
3
2
4
7
2
3
2
2
1
2
3
2
1
First
Addr Data
555
AA
XX
A0
77
data
XX
90
555
AA
XX
A0
0...00 PWD0
00
25
XX
90
555
AA
XX
A0
XX
80
SA
RD(0)
XX
90
555
AA
XX
A0
BA
RD(0)
Sector Protection Commands
XX
00
2AA
55
555
60
00
PWD[0-3]
0...01
PWD1
0...02 PWD2
00
03
00
PWD0
XX
00
2AA
55
[BA]555
C0
SA
00
00
30
XX
2AA
XX
00
55
00
2
XX
90
XX
00
3
2
2
1
2
555
XX
XX
SA
XX
AA
A0
A0
RD(0)
90
2AA
SA
SA
55
00
01
XX
00
Legend:
X = Don’t care.
RA = Address of the memory location to be read.
PD(0) = Secured Silicon Sector Lock Bit. PD(0), or bit[0].
PD(1) = Persistent Protection Mode Lock Bit. PD(1), or bit[1], must
be set to ‘0’ for protection while PD(2), bit[2] must be left as ‘1’.
PD(2) = Password Protection Mode Lock Bit. PD(2), or bit[2], must
be set to ‘0’ for protection while PD(1), bit[1] must be left as ‘1’.
PD(3) = Protection Mode OTP Bit. PD(3) or bit[3].
SA = Sector Address. WS256N = A23–A14; WS128N = A22–A14;
WS064N = A21–A14.
Notes:
1. All values are in hexadecimal.
2. Shaded cells indicate read cycles.
3. Address and data bits not specified in table, legend, or notes are
don’t cares (each hex digit implies 4 bits of data).
4. Writing incorrect address and data values or writing them in the
improper sequence may place the device in an unknown state.
The system must write the reset command to return the device
to reading array data.
5. Entry commands are required to enter a specific mode to enable
instructions only available within that mode.
6. If both the Persistent Protection Mode Locking Bit and the
Password Protection Mode Locking Bit are set at the same time,
the command operation aborts and returns the device to the
default Persistent Sector Protection Mode during 2nd bus cycle.
Note that on all future devices, addresses equal 00h, but is
March 14, 2005 S70WS512N00_00_A0
Bus Cycles (Notes 1–4)
Third
Fourth
Fifth
Addr
Data Addr Data Addr Data
555
40
Second
Addr
Data
2AA
55
77/00
data
[BA]555
50
[BA]555
E0
0...03 PWD3
01
PWD1
02
PWD2
Sixth
Addr Data
03
PWD3
Seventh
Addr Data
00
29
BA = Bank Address. WS256N = A23–A20; WS128N = A22–A20;
WS064N = A21–A18.
PWD3–PWD0 = Password Data. PD3–PD0 present four 16 bit
combinations that represent the 64-bit Password
PWA = Password Address. Address bits A1 and A0 are used to select
each 16-bit portion of the 64-bit entity.
PWD = Password Data.
RD(0), RD(1), RD(2) = DQ0, DQ1, or DQ2 protection indicator bit. If
protected, DQ0, DQ1, or DQ2 = 0. If unprotected, DQ0, DQ1,
DQ2 = 1.
7.
currently 77h for the WS256N only. See Table 9.1 and Table 9.2
for explanation of lock bits.
Exit command must be issued to reset the device into read
mode; device may otherwise be placed in an unknown state.
8.
Entire two bus-cycle sequence must be entered for each portion
of the password.
9. Full address range is required for reading password.
10. See Figure 9.2 for details.
11. The All PPB Erase command pre-programs all PPBs before
erasure to prevent over-erasure.
12. The second cycle address for the lock register program operation
is 77 for S29Ws256N; however, for WS128N and Ws064N this
address is 00.
S70WS512N00 Based MCPs
87
A d v a n c e
13.1
I n f o r m a t i o n
Common Flash Memory Interface
The Common Flash Interface (CFI) specification outlines device and host system software interrogation handshake, which allows specific vendor-specified soft-ware algorithms to be used for
entire families of devices. Software support can then be device-independent, JEDEC ID-independent, and forward- and back-ward-compatible for the specified flash device families. Flash
vendors can standardize their existing interfaces for long-term compatibility.
This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to
address (BA)555h any time the device is ready to read array data. The system can read CFI information at the addresses given in Tables 13.3–13.6) within that bank. All reads outside of the
CFI address range, within the bank, returns non-valid data. Reads from other banks are allowed,
writes are not. To terminate reading CFI data, the system must write the reset command.
The following is a C source code example of using the CFI Entry and Exit functions. Refer to
the Spansion Low Level Driver User’s Guide (available on www.amd.com and
www.fujitsu.com) for general information on Spansion Flash memory software development
guidelines.
/* Example: CFI Entry command */
*( (UINT16 *)bank_addr + 0x555 ) = 0x0098;
/* write CFI entry command
*/
/* Example: CFI Exit command */
*( (UINT16 *)bank_addr + 0x000 ) = 0x00F0;
/* write cfi exit command
*/
For further information, please refer to the CFI Specification (see JEDEC publications JEP137-A
and JESD68.01and CFI Publication 100). Please contact your sales office for copies of these
documents.
Table 13.3
CFI Query Identification String
Addresses
Data
10h
11h
12h
0051h
0052h
0059h
Description
Query Unique ASCII string QRY
13h
14h
0002h
0000h
Primary OEM Command Set
15h
16h
0040h
0000h
Address for Primary Extended Table
17h
18h
0000h
0000h
Alternate OEM Command Set (00h = none exists)
19h
1Ah
0000h
0000h
Address for Alternate OEM Extended Table (00h = none exists)
Table 13.4
Addresses
88
System Interface String
Data
Description
1Bh
0017h
VCC Min. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Ch
0019h
VCC Max. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Dh
0000h
VPP Min. voltage (00h = no VPP pin present)
1Eh
0000h
1Fh
0006h
VPP Max. voltage (00h = no VPP pin present)
Typical timeout per single byte/word write 2N µs
20h
0009h
Typical timeout for Min. size buffer write 2N µs (00h = not supported)
21h
000Ah
Typical timeout per individual block erase 2N ms
22h
0000h
Typical timeout for full chip erase 2N ms (00h = not supported)
23h
0004h
Max. timeout for byte/word write 2N times typical
24h
0004h
Max. timeout for buffer write 2N times typical
25h
0003h
Max. timeout per individual block erase 2N times typical
26h
0000h
Max. timeout for full chip erase 2N times typical (00h = not supported)
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Table 13.5
Device Geometry Definition
Addresses
Data
27h
0019h (WS256N)
0018h (WS128N)
0017h (WS064N)
Description
28h
29h
0001h
0000h
Flash Device Interface description (refer to CFI publication 100)
2Ah
2Bh
0006h
0000h
Max. number of bytes in multi-byte write = 2N
(00h = not supported)
Device Size = 2N byte
2Ch
0003h
Number of Erase Block Regions within device
2Dh
2Eh
2Fh
30h
0003h
0000h
0080h
0000h
Erase Block Region 1 Information
(refer to the CFI specification or CFI publication 100)
31h
00FDh (WS256N)
007Dh (WS128N)
003Dh (WS064N)
32h
33h
34h
0000h
0000h
0002h
35h
36h
37h
38h
0003h
0000h
0080h
0000h
Erase Block Region 3 Information
39h
3Ah
3Bh
3Ch
0000h
0000h
0000h
0000h
Erase Block Region 4 Information
Table 13.6
Erase Block Region 2 Information
Primary Vendor-Specific Extended Query
Addresses
Data
40h
41h
42h
0050h
0052h
0049h
Query-unique ASCII string PRI
43h
0031h
Major version number, ASCII
44h
0034h
Minor version number, ASCII
45h
0100h
46h
0002h
Erase Suspend,
0 = Not Supported, 1 = To Read Only, 2 = To Read & Write
47h
0001h
Sector Protect,
0 = Not Supported, X = Number of sectors in per group
48h
0000h
Sector Temporary Unprotect
00 = Not Supported, 01 = Supported
49h
0008h
Sector Protect/Unprotect scheme
08 = Advanced Sector Protection
4Ah
Description
Address Sensitive Unlock (Bits 1-0), 0 = Required, 1 = Not Required
Silicon Technology (Bits 5-2) 0100 = 0.11 µm
00F3h (WS256N) Simultaneous Operation
007Bh (WS128N)
003Fh (WS064N) Number of Sectors in all banks except boot bank
4Bh
0001h
Burst Mode Type
00 = Not Supported, 01 = Supported
4Ch
0000h
Page Mode Type,
00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page, 04 = 16 Word Page
4Dh
0085h
4Eh
0095h
4Fh
0001h
50h
0001h
March 14, 2005 S70WS512N00_00_A0
ACC (Acceleration) Supply Minimum
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
ACC (Acceleration) Supply Maximum
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
Top/Bottom Boot Sector Flag
0001h = Dual Boot Device
Program Suspend. 00h = not supported
S70WS512N00 Based MCPs
89
A d v a n c e
Table 13.6
90
I n f o r m a t i o n
Primary Vendor-Specific Extended Query (Continued)
Addresses
Data
51h
0001h
Unlock Bypass, 00 = Not Supported, 01=Supported
Description
52h
0007h
Secured Silicon Sector (Customer OTP Area) Size 2N bytes
53h
0014h
Hardware Reset Low Time-out during an embedded
algorithm to read mode Maximum 2N ns
54h
0014h
Hardware Reset Low Time-out not during an embedded
algorithm to read mode Maximum 2N ns
55h
0005h
Erase Suspend Time-out Maximum 2N ns
56h
0005h
Program Suspend Time-out Maximum 2N ns
57h
0010h
Bank Organization: X = Number of banks
58h
0013h (WS256N)
000Bh (WS128N) Bank 0 Region Information. X = Number of sectors in bank
0007h (WS064N)
59h
0010h (WS256N)
0008h (WS128N) Bank 1 Region Information. X = Number of sectors in bank
0004h (WS064N)
5Ah
0010h (WS256N)
0008h (WS128N) Bank 2 Region Information. X = Number of sectors in bank
0004h (WS064N)
5Bh
0010h (WS256N)
0008h (WS128N) Bank 3 Region Information. X = Number of sectors in bank
0004h (WS064N)
5Ch
0010h (WS256N)
0008h (WS128N) Bank 4 Region Information. X = Number of sectors in bank
0004h (WS064N)
5Dh
0010h (WS256N)
0008h (WS128N) Bank 5 Region Information. X = Number of sectors in bank
0004h (WS064N)
5Eh
0010h (WS256N)
0008h (WS128N) Bank 6 Region Information. X = Number of sectors in bank
0004h (WS064N)
5Fh
0010h (WS256N)
0008h (WS128N) Bank 7 Region Information. X = Number of sectors in bank
0004h (WS064N)
60h
0010h (WS256N)
0008h (WS128N) Bank 8 Region Information. X = Number of sectors in bank
0004h (WS064N)
61h
0010h (WS256N)
0008h (WS128N) Bank 9 Region Information. X = Number of sectors in bank
0004h (WS064N)
62h
0010h (WS256N)
0008h (WS128N) Bank 10 Region Information. X = Number of sectors in bank
0004h (WS064N)
63h
0010h (WS256N)
0008h (WS128N) Bank 11 Region Information. X = Number of sectors in bank
0004h (WS064N)
64h
0010h (WS256N)
0008h (WS128N) Bank 12 Region Information. X = Number of sectors in bank
0004h (WS064N)
65h
0010h (WS256N)
0008h (WS128N) Bank 13 Region Information. X = Number of sectors in bank
0004h (WS064N)
66h
0010h (WS256N)
0008h (WS128N) Bank 14 Region Information. X = Number of sectors in bank
0004h (WS064N)
67h
0013h (WS256N)
000Bh (WS128N) Bank 15 Region Information. X = Number of sectors in bank
0007h (WS064N)
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
14 Commonly Used Terms
Term
Definition
ACC
ACCelerate. A special purpose input signal which allows for faster programming or
erase operation when raised to a specified voltage above VCC. In some devices ACC
may protect all sectors when at a low voltage.
Amax
Most significant bit of the address input [A23 for 256Mbit, A22 for128Mbit, A21 for
64Mbit]
Amin
Least significant bit of the address input signals (A0 for all devices in this document).
Asynchronous
Operation where signal relationships are based only on propagation delays and are
unrelated to synchronous control (clock) signal.
Autoselect
Read mode for obtaining manufacturer and device information as well as sector
protection status.
Bank
Section of the memory array consisting of multiple consecutive sectors. A read
operation in one bank, can be independent of a program or erase operation in a
different bank for devices that offer simultaneous read and write feature.
Boot sector
Smaller size sectors located at the top and or bottom of Flash device address space.
The smaller sector size allows for finer granularity control of erase and protection for
code or parameters used to initiate system operation after power-on or reset.
Boundary
Location at the beginning or end of series of memory locations.
Burst Read
See synchronous read.
Byte
8 bits
CFI
Common Flash Interface. A Flash memory industry standard specification [JEDEC 137A and JESD68.01] designed to allow a system to interrogate the Flash to determine its
size, type and other performance parameters.
Clear
Zero (Logic Low Level)
Configuration Register
Special purpose register which must be programmed to enable synchronous read
mode
Continuous Read
Synchronous method of burst read whereby the device reads continuously until it is
stopped by the host, or it has reached the highest address of the memory array, after
which the read address wraps around to the lowest memory array address
Erase
Returns bits of a Flash memory array to their default state of a logical One (High Level).
Erase Suspend/Erase Resume
Halts an erase operation to allow reading or programming in any sector that is not
selected for erasure
BGA
Ball Grid Array package. Spansion LLC offers two variations: Fortified Ball Grid Array
and Fine-pitch Ball Grid Array. See the specific package drawing or connection diagram
for further details.
Linear Read
Synchronous (burst) read operation in which 8, 16, or 32 words of sequential data with
or without wraparound before requiring a new initial address.
MCP
Multi-Chip Package. A method of combining integrated circuits in a single package by
stacking multiple die of the same or different devices.
Memory Array
The programmable area of the product available for data storage.
MirrorBit™ Technology
Spansion™ trademarked technology for storing multiple bits of data in the same
transistor.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
91
A d v a n c e
I n f o r m a t i o n
Term
Definition
Page
Group of words that may be accessed more rapidly as a group than if the words were
accessed individually.
Page Read
Asynchronous read operation of several words in which the first word of the group
takes a longer initial access time and subsequent words in the group take less page
access time to be read. Different words in the group are accessed by changing only the
least significant address lines.
Password Protection
Sector protection method which uses a programmable password, in addition to the
Persistent Protection method, for protection of sectors in the Flash memory device.
Persistent Protection
Sector protection method that uses commands and only the standard core voltage
supply to control protection of sectors in the Flash memory device. This method
replaces a prior technique of requiring a 12V supply to control the protection method.
Program
Stores data into a Flash memory by selectively clearing bits of the memory array in
order to leave a data pattern of ones and zeros.
Program Suspend/Program
Resume
Halts a programming operation to read data from any location that is not selected for
programming or erase.
Read
Host bus cycle that causes the Flash to output data onto the data bus.
Registers
Dynamic storage bits for holding device control information or tracking the status of
an operation.
Secured Silicon
Secured Silicon. An area consisting of 256 bytes in which any word may be
programmed once, and the entire area may be protected once from any future
programming. Information in this area may be programmed at the factory or by the
user. Once programmed and protected there is no way to change the secured
information. This area is often used to store a software readable identification such as
a serial number.
Sector Protection
Use of one or more control bits per sector to indicate whether each sector may be
programmed or erased. If the Protection bit for a sector is set the embedded
algorithms for program or erase ignores program or erase commands related to that
sector.
Sector
An Area of the memory array in which all bits must be erased together by an erase
operation.
Simultaneous Operation
Mode of operation in which a host system may issue a program or erase command to
one bank, that embedded algorithm operation may then proceed while the host
immediately follows the embedded algorithm command with reading from another
bank. Reading may continue concurrently in any bank other than the one executing
the embedded algorithm operation.
Synchronous Operation
Operation that progresses only when a timing signal, known as a clock, transitions
between logic levels (that is, at a clock edge).
VersatileIO™ (VIO)
Separate power supply or voltage reference signal that allows the host system to set
the voltage levels that the device generates at its data outputs and the voltages
tolerated at its data inputs.
Unlock Bypass
Mode that facilitates faster program times by reducing the number of command bus
cycles required to issue a write operation command. In this mode the initial two Unlock
write cycles, of the usual 4 cycle Program command, are not required – reducing all
Program commands to two bus cycles while in this mode.
Word
Two contiguous bytes (16 bits) located at an even byte boundary. A double word is two
contiguous words located on a two word boundary. A quad word is four contiguous
words located on a four word boundary.
92
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005
A d v a n c e
I n f o r m a t i o n
Term
Definition
Wraparound
Special burst read mode where the read address wraps or returns back to the lowest
address boundary in the selected range of words, after reading the last Byte or Word
in the range, e.g. for a 4 word range of 0 to 3, a read beginning at word 2 would read
words in the sequence 2, 3, 0, 1.
Write
Interchangeable term for a program/erase operation where the content of a register
and or memory location is being altered. The term write is often associated with writing
command cycles to enter or exit a particular mode of operation.
Write Buffer
Multi-word area in which multiple words may be programmed as a single operation. A
Write Buffer may be 16 to 32 words long and is located on a 16 or 32 word boundary
respectively.
Write Buffer Programming
Method of writing multiple words, up to the maximum size of the Write Buffer, in one
operation. Using Write Buffer Programming results in ≥ 8 times faster programming
time than by using single word at a time programming commands.
Write Operation Status
Allows the host system to determine the status of a program or erase operation by
reading several special purpose register bits.
March 14, 2005 S70WS512N00_00_A0
S70WS512N00 Based MCPs
93
A d v a n c e
I n f o r m a t i o n
15 Revisions
Revision A0 (March 14, 2005)
Initial Release
Colophon
The products described in this document are designed, developed and manufactured as contemplated for general use, including without limitation, ordinary
industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as contemplated (1) for any use that
includes fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal
injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control,
medical life support system, missile launch control in weapon system), or (2) for any use where chance of failure is intolerable (i.e., submersible repeater and
artificial satellite). Please note that Spansion LLC will not be liable to you and/or any third party for any claims or damages arising in connection with abovementioned uses of the products. Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such
failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels
and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the US Export Administration Regulations or the applicable laws of any other country, the
prior authorization by the respective government entity will be required for export of those products.
Trademarks and Notice
The contents of this document are subject to change without notice. This document may contain information on a Spansion LLC product under development
by Spansion LLC. Spansion LLC reserves the right to change or discontinue work on any product without notice. The information in this document is provided
as is without warranty or guarantee of any kind as to its accuracy, completeness, operability, fitness for particular purpose, merchantability, non-infringement
of third-party rights, or any other warranty, express, implied, or statutory. Spansion LLC assumes no liability for any damages of any kind arising out of the
use of the information in this document.
Copyright ©2005 Spansion LLC. All rights reserved. Spansion, the Spansion logo, and MirrorBit are trademarks of Spansion LLC. Other company and product
names used in this publication are for identification purposes only and may be trademarks of their respective companies.
94
S70WS512N00 Based MCPs
S70WS512N00_00_A0 March 14, 2005