TI SN74ALS112AN

SN54ALS112A, SN74ALS112A
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDAS199A – APRIL 1982 – REVISED DECEMBER 1994
•
SN54ALS112A . . . J PACKAGE
SN74ALS112A . . . D OR N PACKAGE
(TOP VIEW)
Fully Buffered to Offer Maximum Isolation
From External Disturbance
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
TYPE
′ALS112A
TYPICAL MAXIMUM
CLOCK
FREQUENCY
(MHz)
TYPICAL POWER
DISSIPATION
PER FLIP-FLOP
(mW)
50
6
1CLK
1K
1J
1PRE
1Q
1Q
2Q
GND
description
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
1CLR
2CLR
2CLK
2K
2J
2PRE
2Q
SN54ALS112A . . . FK PACKAGE
(TOP VIEW)
1K
1CLK
NC
VCC
These devices contain two independent J-K
negative-edge-triggered flip-flops. A low level at
the preset (PRE) or clear (CLR) inputs sets or
resets the outputs, regardless of the levels of the
other inputs. When PRE and CLR are inactive
(high), data at the J and K inputs meeting the
setup-time requirements is transferred to the
outputs on the negative-going edge of the clock
pulse (CLK). Clock triggering occurs at a voltage
level and is not directly related to the fall time of the
clock pulse. Following the hold-time interval, data
at the J and K inputs may be changed without
affecting the levels at the outputs. These versatile
flip-flops can perform as toggle flip-flops by tying
J and K high.
3
4
2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
2CLR
2CLK
NC
2K
2J
2Q
GND
NC
2Q
2PRE
1J
1PRE
NC
1Q
1Q
1CLR
•
NC – No internal connection
The SN54ALS112A is characterized for operation over the full military temperature range of – 55°C to 125°C.
The SN74ALS112A is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
(each flip-flop)
INPUTS
OUTPUTS
PRE
CLR
CLK
J
K
Q
Q
L
H
X
X
X
H
L
H
L
X
X
X
L
L
X
X
X
L
H†
H
H†
H
H
↓
L
L
Q0
Q0
H
H
↓
H
L
H
L
H
H
↓
L
H
L
H
H
↓
H
H
H
Toggle
H
H
H
X
X
Q0
Q0
† The output levels in this configuration may not meet the
minimum levels for VOH. Furthermore, this configuration is
nonstable; that is, it does not persist when either PRE or
CLR returns to its inactive (high) level.
Copyright  1994, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54ALS112A, SN74ALS112A
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDAS199A – APRIL 1982 – REVISED DECEMBER 1994
logic symbol†
1PRE
1J
1CLK
1K
1CLR
2PRE
2J
2CLK
2K
2CLR
4
3
S
5
1J
1
2
15
1Q
C1
6
1K
1Q
R
10
9
11
2Q
13
12
7
2Q
14
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
logic diagram (positive logic)
Q
Q
PRE
CLR
J
K
CLK
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54ALS112A . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS112A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS112A, SN74ALS112A
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDAS199A – APRIL 1982 – REVISED DECEMBER 1994
recommended operating conditions
SN54ALS112A
SN74ALS112A
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.7
0.8
High-level output current
– 0.4
– 0.4
mA
IOL
fclock
Low-level output current
4
8
mA
30
MHz
tw
High-level input voltage
2
Clock frequency
2
0
Pulse duration
tsu
Set p time before CLK↓
Setup
th
TA
Hold time after CLK↓
25
15
10
CLK high
20
16.5
CLK low
20
16.5
Data
25
22
PRE or CLR inactive
22
20
Data
Operating free-air temperature
0
V
0
PRE or CLR low
125
V
ns
ns
0
– 55
V
ns
0
70
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VIK
VOH
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = –18 mA
IOH = – 0.4 mA
VOL
VCC = 4
4.5
5V
IOL = 4 mA
IOL = 8 mA
VCC = 5
5.5
5V
V,
VI = 7 V
VCC = 5
5.5
5V
V,
VI = 2
2.7
7V
VCC = 5
5.5
5V
V,
VI = 0
0.4
4V
II
IIH
IIL
J, K, or CLK
PRE or CLR
J, K, or CLK
PRE or CLR
J, K, or CLK
PRE or CLR
SN54ALS112A
MIN TYP†
MAX
SN74ALS112A
MIN TYP†
MAX
–1.5
VCC – 2
–1.5
VCC – 2
0.25
0.4
UNIT
V
V
0.25
0.4
0.35
0.5
0.1
0.1
0.2
0.2
20
20
40
40
– 0.2
– 0.2
– 0.4
– 0.4
V
mA
µA
mA
IO‡
VCC = 5.5 V,
VO = 2.25 V
– 20
–112
– 30
–112
mA
ICC
VCC = 5.5 V,
See Note 1
2.5
4.5
2.5
4.5
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
NOTE 1: ICC is measured with J, K, CLK, and PRE grounded, then with J, K, CLK, and CLR grounded.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
SN54ALS112A, SN74ALS112A
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDAS199A – APRIL 1982 – REVISED DECEMBER 1994
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX†
SN54ALS112A SN74ALS112A
MIN
fmax
tPLH
tPHL
tPLH
MAX
MIN
25
PRE or CLR
Q or Q
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
MAX
30
MHz
3
26
3
15
4
23
4
18
3
15
5
19
3
23
CLK
Q or Q
tPHL
5
24
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
UNIT
ns
ns
SN54ALS112A, SN74ALS112A
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDAS199A – APRIL 1982 – REVISED DECEMBER 1994
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7V
RL = R1 = R2
VCC
S1
RL
R1
Test
Point
From Output
Under Test
CL
(see Note A)
From Output
Under Test
RL
Test
Point
From Output
Under Test
CL
(see Note A)
CL
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
3.5 V
Timing
Input
Test
Point
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
High-Level
Pulse
1.3 V
R2
1.3 V
1.3 V
0.3 V
0.3 V
tsu
Data
Input
tw
th
3.5 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
0.3 V
1.3 V
0.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
0.3 V
tPZL
Waveform 1
S1 Closed
(see Note B)
tPLZ
[3.5 V
1.3 V
tPHZ
tPZH
Waveform 2
S1 Open
(see Note B)
1.3 V
VOL
0.3 V
VOH
1.3 V
0.3 V
[0 V
3.5 V
1.3 V
Input
1.3 V
0.3 V
tPHL
tPLH
VOH
In-Phase
Output
1.3 V
1.3 V
VOL
tPLH
tPHL
VOH
Out-of-Phase
Output
(see Note C)
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated