TRUMPOWER PM40-31AL

40 WATT MEDICAL POWER SUPPLIES
DESCRIPTION
PM40AL SERIES
(MDD)
The PM40AL series of compact, open PCB constructed, AC-DC
switching power supplies are capable of delivering 40 watts of
continuous output power. They operate at 85 to 264 VAC
input voltage without the need of voltage selection. They are
ideally suited for use in medical equipment, safety systems and
monitoring equipment, not for patient contact.
F E ATU R E S
‧
‧
‧
‧
‧
‧
‧
Low safety ground leakage current
100% burn-in
W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C
Input surge current protection
Overvoltage protection
Overcurrent protection
Open PCB construction
S a f e t y St a n d a r d A p p ro v a ls :
I N P U T S P E C I F I C ATI O N S
Input voltage:
Input frequency:
Input current:
85 to 264 VAC
UL 2601-1
47 to 63 Hz
Leakage current:
1.20A(rms)for 115VAC
CSA C22.2 No. 601.1
0.70A(rms)for 230VAC
150uA max. @ 230VAC, 50Hz
TÜV EN60601-1
90 uA max. @ 115VAC, 60Hz
GENERAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Output voltage/current:
See rating chart
Total output power:
Ripple and noise:
Overvoltage protection:
40 watts maximum
1﹪ peak to peak maximum
Provided on output #1 only; set at
112 - 132﹪ of its nominal output
voltage
All outputs protected to short
circuit conditions
All outputs ±0.04﹪ /℃ maximum
Maximum excursion of 4﹪ or
better on all models, recovering to
1﹪ of final value within 500us
after a 25﹪ step load change
Overcurrent protection:
Temperature coefficient:
Transient response:
E N V I R O N M E N TA L S P E C I F I C ATI O N S
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
0℃ to +70℃
-40℃ to +85℃
5﹪to 95﹪non-condensing
Derate from 100﹪ at +50℃ linearly to
50% at +70℃
Switching frequency:
36KHz ±5KHz
Efficiency:
70﹪ minimum on single output models
with Vo≧ 15V, 65% minimum on the
others
10 msec minimum at 110VAC
±0.5﹪ maximum at full load
Hold-up time:
Line regulation:
Inrush current:
15 amps @ 115VAC, or 30 amps @
230VAC, at 25℃ cold start
Withstand voltage:
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
600,000 hours minimum at full load at
25℃ ambient, calculated per
MIL-HDBK-217F
EMC Performance (EN60601-1-2: 2001)
Class B conducted, class B radiated
EN55011
Class B conducted, class B radiated
FCC
Class B conducted, class B radiated
VCCI
Harmonic distortion, class A and D
EN61000-3-2
Line flicker
EN61000-3-3
ESD, ± 8KV air and ± 6KV contact
EN61000-4-2
Radiated immunity, 3V/m for 80~2500MHz
EN61000-4-3
Fast transient/burst, ± 2KV
EN61000-4-4
Surge, ± 1KV diff., ± 2KV com.
EN61000-4-5
Conducted immunity, 3Vrms
EN61000-4-6
Magnetic field immunity, 3A/m
EN61000-4-8
Voltage dips, 30% reduction for 500ms,
EN61000-4-11
60% reduction for 100ms and >95%
reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● [email protected] ● www.TRUMPower.com
PM40AL SERIES
MEDICAL GRADE
OUTPUT VOLTAGE/CURRENT RATING CHART
Output #1
Imin. Imax.
0A
8.0A
Vnom.
5V
PM40-12AL
12V
0A
3.5A
1%
(N/A)
(N/A)
40W
PM40-13AL
15V
0A
3.0A
1%
(N/A)
(N/A)
40W
PM40-14AL
24V
0A
2.0A
1%
(N/A)
(N/A)
40W
PM40-18AL
48V
0A
0.9A
1%
(N/A)
(N/A)
40W
PM40-23AL
+5V
0.5A
3.0A
3%
+12V
0.2A
2A
5%
(N/A)
40W
PM40-24AL
+5V
0.5A
3.0A
3%
+15V
0.2A
2A
5%
(N/A)
40W
PM40-25AL
+5V
0.5A
3.0A
3%
+24V
0.1A
1A
5%
(N/A)
40W
Tol.
2%
Vnom.
Output #2
Imin.
Imax.
(N/A)
Tol.
Vnom.
Output #3
Imin. Imax.
(N/A)
Maximum
Output
Power
40W
(1)(2)
Model
PM40-10AL
Tol.
PM40-30AL
+5V
0.5A
3.0A
3%
+12V
0.2A
2A
5%
-5V
0.05A
0.3A
10%
40W
PM40-31AL
+5V
0.5A
3.0A
3%
+12V
0.2A
2A
5%
-12V
0.05A
0.3A
10%
40W
PM40-32AL
+5V
0.5A
3.0A
3%
+15V
0.2A
2A
5%
-15V
0.05A
0.3A
10%
40W
PM40-33AL
+5V
0.5A
3.0A
3%
+15V
0.2A
2A
5%
-12V
0.05A
0.3A
10%
40W
PM40-39AL
+5V
0.5A
3.0A
3%
+24V
0.1A
1A
5%
-12V
0.05A
0.3A
10%
40W
Notes:
(1) All multiple output models may be operated at no-load without damage. At no-load, output voltage tolerance increases
to 10%
(2) Safety agency approvals are for the above listed models in PCB format. To order a model with a metallic L-bracket or
box, change suffix “AL” to “BL” for L-bracket format or to “CL” for enclosed format (mechanical details shown in page
7-1), e.g. PM40-14BL.
MECHANICAL SPECIFICATIONS
NOTES:
1. Dimensions shown in inch [mm]
2. Tolerance 0.02 [0.5] maximum
3. Input connector mates with Molex housing
09-50-3031 and Molex 2878 series crimp
terminal.
4. Output connector mates with Molex housing
09-50-3061 and Molex 2878 series crimp
terminal.
5. Weight: 230 grams (PCB format)
6. It’s strongly recommended to connect the two
“*” marked mounting holes to system chassis
through metallic stand-offs. This helps reduce
greatly output noise.
PIN CHART
PIN
MODEL
PM40-10AL
PM40-13AL
PM40-18AL
PM40-23AL
PM40-25AL
PM40-30AL
PM40-32AL
PM40-39AL
1
2
3
4
5
6
OUTPUT
#1
OUTPUT
#1
OUTPUT
#1
RETURN
RETURN
RETURN
PM40-24AL
OUTPUT
#2
OUTPUT
#1
OUTPUT
#1
COMMON
RETURN
COMMON
RETURN
N.C.
PM40-31AL
PM40-33AL
OUTPUT
#2
OUTPUT
#1
OUTPUT
#1
COMMON
RETURN
COMMON
RETURN
OUTPUT
#3
PM40-12AL
PM40-14AL
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● [email protected] ● www.TRUMPower.com