DB LECTRO INC NSG-1&NSG-2 30.5×30.5×40 Features n n n Stable electronic timing. Wide operating voltage and temperature range. Suitable for feast lignt during car turning. Coil Parameter Rated voltage 12VDC,24VDC Operating voltage drop <0.4VDC at rated turn signal load Device voltage drop <0.45VDC at rated hazard signal load Initial turn-on 50ms Sound pressure level 70dB Upper limit temperature for the coil 125ºC Characteristics Contact Arrangement Max output power Shock Resistance Vibration Resistance Ambient temperature 1A 98W 200m/s 2 10ms Half sine wave pulse IEC68-2-27 Test Ea 10~40Hz Double amplitude 1.27mm IEC68-2-6 Test Fc 40~70Hz 50m/s 2 70~100Hz Double amplitude 0.5mm IEC68-2-6 Test Fc 100~500Hz 100m/s 2 Capable of meeting specifications 1m drop onto concrete IEC68-2-32 Test Ed method 1 Loads 2Lamp system 3Lamp system 2x21W 3x21W +1x5W +1x5W Turn signal mode:Rated loads +1x1.2W +1x1.2W 1x21W 2x21W Outage loads +1x5W +1x5W +1x1.2W +1x1.2W 4x21W 6x21W Hazard mode:Rated loads +2x5W +2x5W +2x1.2W +2x1.2W -40~85 ºC Relative humidity 20 ~ 50 % at 23 ºC Mass 35g Approx Drop test Contact data: Load requirements at 12.8VDC 119 NSG-1&NSG-2 Ordering Information NSG-1 A Z Z=Dust Covered Contact Arrangement :A=1A Part number :NSG-1, NSG-2 Dimensions (Unit: mm) NSG-1 30.5 40 16.8 49a 3 49 40 31 31 49 49a 30.5 Mounting (Bottom views) 31 49 mm 0.5 0.8 6.3 8.4 11.5 16.8 30.5 40 inch 0.020 0.031 0.248 0.331 0.453 0.661 1.201 1.575 30.5 0.5 3-6.3x0.8 8.4 49a NSG-2 11.5 16.8 8.4 8.4 31 8.4 49 30.5 0.5 3-6.3x0.8 11.5 49a R - C + 9 IC J Dimensions R R - 31 + 49 R 49a Wiring diagram NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. DB LECTRO INC . 120