QUICKTRONIC fit T5 osram.com QUICKTRONIC fit T5 QT-FIT5 ECG for T5/∅16mm linear fluorescent lamps QT- FIT5 i.e. LUMILUX® T5 GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 01 QUICKTRONIC fit T5 Product Features: • • • • • • • • • 1 50,000 hours lifetime Lamp start with optimized filament preheating within 2 s Suitable for lighting with very high switching cycles Reliable lamp ignition between -15°C...+50°C Suitable for luminaries of protection class I CELMA Energy Efficiency Index A2 Automatic safety shut-down in case of a defect or at the end of the lamp’s life (EoL T.2) Automatic restart after lamp replacement Suitable for DC installations Technical Data Max. cable diameter for 2 push-in contact [mm ]: 2 s : 0.5 - 1.5 Starting time: t: 2 sec. Line voltage: 220 - 240 V Voltage range (AC): 198 - 264 V Voltage range (DC): 185 – 276 V; for lamp ignition min. 198 V; max. 1 hour 185 - 198V Line frequency: 50 - 60 Hz Operating frequency: 40 - 50 kHz Electrical strength: Ambient temperature ta: Measuring point temperature tc: U-OUT: 1 2 280 V permanent; 300 V 2 hours -15°C to +50 °C Max. +75 °C 430 V (330 V for QT-FIT5 1x14-35) Average lifetime s = solid wire GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 02 QUICKTRONIC fit T5 Inrush current and max. number of ECG per circuit breaker ECG QT- FIT5 QT- FIT5 QT- FIT5 QT- FIT5 QT- FIT5 Inrush Current Ip [A] 24 40 40 24 53 1x14-35 2x14-35 3x14, 4x14 1x49 2x49 Max. number of ECG per circuit breaker TH [µs] 230 200 200 230 200 B: 10A 17 12 12 17 8 B: 16A 28 19 19 28 13 C: 16 A 47 32 32 47 22 Standards and approval marks Safety: acc. to EN 61347-2-3 / IEC 61347-2-3 Radio interference: acc. EN 55015: 2006 + A1: 2007 + A2: 2009 Harmonic content: acc. to EN 61000-3-2 / IEC 61000-3-2 Immunity: acc. to EN 61547 / IEC 61547 Approval marks: Dimensions & weight Description Description Length [mm] Width [mm] Height [mm] Distance Mounting Holes [mm] Weight [g] QT-FIT5 1x14-35 280 30 21 270 160 QT-FIT5 2x14-35 QT-FIT5 3x14, 4x14 280 280 30 40 21 21 270 270 185 220 QT-FIT5 1x49 280 30 21 270 165 QT-FIT5 2x49 280 30 21 270 185 GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 03 QUICKTRONIC fit T5 Lamp wiring QT-FIT5 1x… 1 ~ 2 3 ~ 220... 240 V 21 22 23 24 QT-FIT5 1x... leads max 2m L leads max 1m Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.0 m (PIN 23, 24) QT-FIT5 2x… Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.5 m (PIN 23, 24); 1.0 m (PIN 25, 26) 1 ~ 2 3 ~ 220... 240 V 21 22 23 24 25 26 QT-FIT5 2x... leads max 2m L leads max 1m L QT -FIT5 3x14, 4x14, 3 lamp operation 1 ~ 2 3 ~ 220... 240 V QT-FIT5 3, 4 x... 4 5 6 7 21 22 23 24 25 26 L L L Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 25, 26); 1.5 m (PIN 4, 5, 21, 22, 23, 24) GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 04 QUICKTRONIC fit T5 QT -FIT5 3x14, 4x14, 4 lamp operation 1~ 2 3~ 220... 240 V QT-FIT5 3, 4 x... 4 5 6 7 21 22 23 24 25 26 L L L L Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 6, 7, 25, 26); 1.5 m (PIN 4, 5, 21, 22, 23, 24) Logistic Data Description EAN 10 EAN 40 Packaging Unit QT-FIT5 1x14-35 4008321971234 4008321971241 20 QT-FIT5 2x14-35 4008321971258 4008321971265 20 QT-FIT5 3x14, 4x14 4008321971210 4008321971227 20 QT-FIT5 1x49 4008321832139 4008321832146 20 QT-FIT5 2x49 4008321832153 4008321832160 20 GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 05 QUICKTRONIC fit T5 Lifetime Measuring point temperature tc: Lifetime with max. 10% failure rate 75 °C 30,000 h 70 °C 50,000 h Expected lifetime ECG ambient temperature (ta) ECG Lamp 40°C HE 14 W HE 21 W HE 28 W HE 35 W QT- FIT5 1x14-35 HE ES13 W HE ES 19 W HE ES 25 W HE ES 32 W HE 14 W HE 21 W HE 28 W HE 35 W 1 QT- FIT5 2x14-35 HE ES13 W HE ES 19 W HE ES 25 W HE ES 32 W QT- FIT5 3x14, 4x14 QT- FIT5 3x14, 4x14 1 HE 14 W (3lamp operation) HE 14 W (4lamp operation) HE ES13 W (3lamp operation) HE ES 13 W (4lamp operation) lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] 100,000 45 100,000 45 100,000 50 100,000 45 100.000 45 100,000 50 100,000 50 100,000 55 70,000 60 90,000 60 100,000 55 100,000 55 50°C in preparation in preparation 100,000 55 100,000 55 100,000 55 100,000 55 100.000 55 100,000 55 100,000 55 in preparation in preparation in preparation in preparation 70,000 65 40,000 70 in preparation in preparation in preparation in preparation in preparation in preparation 60,000 65 in preparation in preparation 60,000 65 in preparation in preparation 80,000 60 60°C 60,000 65 60,000 65 60,000 65 70,000 65 60.000 65 60,000 65 60,000 65 50,000 70 x x x x 30,000 75 50,000 70 GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 06 QUICKTRONIC fit T5 ECG ECG ambient temperature (ta) Lamp HO 49 QT-FIT5 1x49 HO ES 45 W HO 49 QT-FIT5 2x49 HO ES 45 W lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] 40°C 50°C 60°C 100,000 55 100,000 50 70,000 60 80,000 60 in preparation in preparation in preparation in preparation 40,000 70 50,000 70 1 ECG ECG ambient temperature (ta) Lamp HE 35 W QT- FIT5 2x14-35 HE ES 32 W 58°C lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] 30,000 75 30,000 75 Expected lifetime is the calculation of the ECG lifetime according to IEC_60929_Edition_4_2011. As background for this estimation, are the MTTF values according to SN 29500 and the component- parameters used GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 07 QUICKTRONIC fit T5 Lamp/ECG System Combination ECG QT-FIT5 1x14-35 QT-FIT5 2x14-35 QT-FIT5 3x14, 4x14 QT-FIT5 1x49 QT-FIT5 2x49 Lamp HE 14 HE 21 HE 28 HE 35 HE ES 13 W HE ES 19 W HE ES 25 W HE ES 32 W HE 14 HE 21 HE 28 HE 35 HE ES13 W HE ES 19 W HE ES 25 W HE ES 32 W HE 14 HE 14 HE ES13 W HE ES13 W HO 49 HO ES 45 W HO 49 HO ES 45 W HF lamp wattage [W] 14 21 28 35 13 19 25 32 2x 14 2x 21 2x 28 2x 35 2x 13 2x 19 2x 25 2x 32 3x 14 4x 14 3x 13 4x 13 49 45 2x 49 2x 45 System wattage [W] 16 23 31 38 15 22 28 35 32 46 61 78 29 43 56 71 49 63 43 56 54 50 106 97 Line current [A] 0.08 0.11 0.14 0.17 0.07 0.09 0.13 0.15 0.15 0.22 0.28 0.35 0.13 0.19 0.25 0.32 0.22 0.28 0.19 0.25 0.24 0.22 0.47 0.42 Luminous flux at 25°C [lm] 1200 1900 2600 3320 1150 1800 2450 3100 2x 1200 2x 1900 2x 2600 2x 3320 2x 1150 2x 1800 2x 2450 2x 3100 3x 1200 4x 1200 3x 1150 4x 1150 4310 4310 2x 4300 2x 4310 Luminous flux at 35°C [lm] 1350 2100 2900 3650 1350 2100 2900 3650 2x 1350 2x 2100 2x 2900 2x 3650 2x 1350 2x 2100 2x 2900 2x 3650 3x 1350 4x 1350 3x 1350 4x 1350 4900 4900 2x 4900 2x 4900 Power factor [λ] 0.95 0.95 0.96 0.97 0.95 0.95 0.96 0.97 0.98 0.98 0.98 0.98 0.95 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 For more information on ECG refer to http://www.osram.com For more information on System Guarantee refer to http://www.osram.com GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 08