QUICKTRONIC fit T5 QT-FIT5

QUICKTRONIC fit T5
osram.com
QUICKTRONIC fit T5
QT-FIT5
ECG for T5/∅16mm linear fluorescent
lamps
QT- FIT5
i.e. LUMILUX® T5
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
01
QUICKTRONIC fit T5
Product Features:
•
•
•
•
•
•
•
•
•
1
50,000 hours lifetime
Lamp start with optimized filament preheating within 2 s
Suitable for lighting with very high switching cycles
Reliable lamp ignition between -15°C...+50°C
Suitable for luminaries of protection class I
CELMA Energy Efficiency Index A2
Automatic safety shut-down in case of a defect or at the end of the lamp’s life (EoL T.2)
Automatic restart after lamp replacement
Suitable for DC installations
Technical Data
Max. cable diameter for
2
push-in contact [mm ]:
2
s : 0.5 - 1.5
Starting time:
t: 2 sec.
Line voltage:
220 - 240 V
Voltage range (AC):
198 - 264 V
Voltage range (DC):
185 – 276 V; for lamp ignition min. 198 V; max. 1 hour 185 - 198V
Line frequency:
50 - 60 Hz
Operating frequency:
40 - 50 kHz
Electrical strength:
Ambient temperature ta:
Measuring point temperature tc:
U-OUT:
1
2
280 V  permanent; 300 V  2 hours
-15°C to +50 °C
Max. +75 °C
430 V (330 V for QT-FIT5 1x14-35)
Average lifetime
s = solid wire
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
02
QUICKTRONIC fit T5
Inrush current and max. number of ECG per circuit breaker
ECG
QT- FIT5
QT- FIT5
QT- FIT5
QT- FIT5
QT- FIT5
Inrush Current
Ip [A]
24
40
40
24
53
1x14-35
2x14-35
3x14, 4x14
1x49
2x49
Max. number of ECG per circuit breaker
TH [µs]
230
200
200
230
200
B: 10A
17
12
12
17
8
B: 16A
28
19
19
28
13
C: 16 A
47
32
32
47
22
Standards and approval marks
Safety:
acc. to EN 61347-2-3 / IEC 61347-2-3
Radio interference:
acc. EN 55015: 2006 + A1: 2007 + A2: 2009
Harmonic content:
acc. to EN 61000-3-2 / IEC 61000-3-2
Immunity:
acc. to EN 61547 / IEC 61547
Approval marks:
Dimensions & weight
Description
Description
Length
[mm]
Width
[mm]
Height
[mm]
Distance
Mounting
Holes [mm]
Weight [g]
QT-FIT5 1x14-35
280
30
21
270
160
QT-FIT5 2x14-35
QT-FIT5 3x14, 4x14
280
280
30
40
21
21
270
270
185
220
QT-FIT5 1x49
280
30
21
270
165
QT-FIT5 2x49
280
30
21
270
185
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
03
QUICKTRONIC fit T5
Lamp wiring
QT-FIT5 1x…
1 ~
2
3 ~
220...
240 V
21
22
23
24
QT-FIT5 1x...
leads max 2m
L
leads max 1m
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.0 m (PIN 23, 24)
QT-FIT5 2x…
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.5 m (PIN 23, 24); 1.0 m (PIN 25,
26)
1 ~
2
3 ~
220...
240 V
21
22
23
24
25
26
QT-FIT5 2x...
leads max 2m
L
leads max 1m
L
QT -FIT5 3x14, 4x14, 3 lamp operation
1 ~
2
3 ~
220...
240 V
QT-FIT5 3, 4 x...
4
5
6
7
21
22
23
24
25
26
L
L
L
Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 25, 26); 1.5 m (PIN 4, 5, 21, 22, 23, 24)
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
04
QUICKTRONIC fit T5
QT -FIT5 3x14, 4x14, 4 lamp operation
1~
2
3~
220...
240 V
QT-FIT5 3, 4 x...
4
5
6
7
21
22
23
24
25
26
L
L
L
L
Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 6, 7, 25, 26); 1.5 m (PIN 4, 5, 21, 22, 23, 24)
Logistic Data
Description
EAN 10
EAN 40
Packaging Unit
QT-FIT5 1x14-35
4008321971234
4008321971241
20
QT-FIT5 2x14-35
4008321971258
4008321971265
20
QT-FIT5 3x14, 4x14
4008321971210
4008321971227
20
QT-FIT5 1x49
4008321832139
4008321832146
20
QT-FIT5 2x49
4008321832153
4008321832160
20
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
05
QUICKTRONIC fit T5
Lifetime
Measuring point
temperature tc:
Lifetime
with max. 10% failure rate
75 °C
30,000 h
70 °C
50,000 h
Expected lifetime
ECG ambient temperature (ta)
ECG
Lamp
40°C
HE 14 W
HE 21 W
HE 28 W
HE 35 W
QT- FIT5 1x14-35
HE ES13 W
HE ES 19 W
HE ES 25 W
HE ES 32 W
HE 14 W
HE 21 W
HE 28 W
HE 35 W
1
QT- FIT5 2x14-35
HE ES13 W
HE ES 19 W
HE ES 25 W
HE ES 32 W
QT- FIT5 3x14,
4x14
QT- FIT5 3x14,
4x14
1
HE 14 W
(3lamp operation)
HE 14 W
(4lamp operation)
HE ES13 W
(3lamp operation)
HE ES 13 W
(4lamp operation)
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
100,000
45
100,000
45
100,000
50
100,000
45
100.000
45
100,000
50
100,000
50
100,000
55
70,000
60
90,000
60
100,000
55
100,000
55
50°C
in preparation
in preparation
100,000
55
100,000
55
100,000
55
100,000
55
100.000
55
100,000
55
100,000
55
in preparation
in preparation
in preparation
in preparation
70,000
65
40,000
70
in preparation
in preparation
in preparation
in preparation
in preparation
in preparation
60,000
65
in preparation
in preparation
60,000
65
in preparation
in preparation
80,000
60
60°C
60,000
65
60,000
65
60,000
65
70,000
65
60.000
65
60,000
65
60,000
65
50,000
70
x
x
x
x
30,000
75
50,000
70
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
06
QUICKTRONIC fit T5
ECG
ECG ambient temperature (ta)
Lamp
HO 49
QT-FIT5 1x49
HO ES 45 W
HO 49
QT-FIT5 2x49
HO ES 45 W
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
40°C
50°C
60°C
100,000
55
100,000
50
70,000
60
80,000
60
in preparation
in preparation
in preparation
in preparation
40,000
70
50,000
70
1
ECG
ECG ambient temperature (ta)
Lamp
HE 35 W
QT- FIT5 2x14-35
HE ES 32 W
58°C
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
30,000
75
30,000
75
Expected lifetime is the calculation of the ECG lifetime according to
IEC_60929_Edition_4_2011. As background for this estimation, are the MTTF values
according to SN 29500 and the component- parameters used
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
07
QUICKTRONIC fit T5
Lamp/ECG System Combination
ECG
QT-FIT5 1x14-35
QT-FIT5 2x14-35
QT-FIT5 3x14, 4x14
QT-FIT5 1x49
QT-FIT5 2x49
Lamp
HE 14
HE 21
HE 28
HE 35
HE ES 13 W
HE ES 19 W
HE ES 25 W
HE ES 32 W
HE 14
HE 21
HE 28
HE 35
HE ES13 W
HE ES 19 W
HE ES 25 W
HE ES 32 W
HE 14
HE 14
HE ES13 W
HE ES13 W
HO 49
HO ES 45 W
HO 49
HO ES 45 W
HF lamp
wattage [W]
14
21
28
35
13
19
25
32
2x 14
2x 21
2x 28
2x 35
2x 13
2x 19
2x 25
2x 32
3x 14
4x 14
3x 13
4x 13
49
45
2x 49
2x 45
System
wattage [W]
16
23
31
38
15
22
28
35
32
46
61
78
29
43
56
71
49
63
43
56
54
50
106
97
Line current [A]
0.08
0.11
0.14
0.17
0.07
0.09
0.13
0.15
0.15
0.22
0.28
0.35
0.13
0.19
0.25
0.32
0.22
0.28
0.19
0.25
0.24
0.22
0.47
0.42
Luminous flux at
25°C [lm]
1200
1900
2600
3320
1150
1800
2450
3100
2x 1200
2x 1900
2x 2600
2x 3320
2x 1150
2x 1800
2x 2450
2x 3100
3x 1200
4x 1200
3x 1150
4x 1150
4310
4310
2x 4300
2x 4310
Luminous flux at
35°C [lm]
1350
2100
2900
3650
1350
2100
2900
3650
2x 1350
2x 2100
2x 2900
2x 3650
2x 1350
2x 2100
2x 2900
2x 3650
3x 1350
4x 1350
3x 1350
4x 1350
4900
4900
2x 4900
2x 4900
Power factor
[λ]
0.95
0.95
0.96
0.97
0.95
0.95
0.96
0.97
0.98
0.98
0.98
0.98
0.95
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
For more information on ECG refer to http://www.osram.com
For more information on System Guarantee refer to http://www.osram.com
GL SCL EU&LM TLS ECG13 Edition:.11.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
08