EPCOS B81130-C1684-M

EMI Suppression Capacitors
B 81 130
X2 / 275 Vac
X2 capacitors with very small dimensions
Rated ac voltage 275 V, 50/60 Hz
Construction
■
■
■
■
Dielectric: polypropylene (MKP)
Plastic case (UL 94 V-0)
Epoxy resin sealing, flame-retardant
Impregnated
Features
■ Very small dimensions
■ Self-healing properties
Lead spacing
± 0,4
Terminals
■ Parallel wire leads, tinned
■ Two standard lead lengths
available: 6 mm und 26 mm
Other lead lengths available upon request.
Lead diameter Lead length l1
∅d (mm)
(mm)
10 mm
0,6
6–1
—
≥ 15 mm
0,8
6–1
26 ± 2
Lead spacing = 10 mm Lead spacing ≥ 15 mm
(22 nF ... 1,0 µF)
Marking
Manufacturer’s logo and lot number
date code,
rated capacitance (coded),
capacitance tolerance (code letter),
rated ac voltage, type number,
interference suppression sub-class (X2),
style (MKP), climatic category,
awarded marks of conformity.
AAAAA C1103
XX-10n M 275V~
AAAAA C1104
XX-µ1 M 275V~
B81130 X2 MKP/SH
40/100/21/C
B81130 X2 MKP/SH
40/100/21/C
V
D E
V
D E
IEC 384-14(2)
KMK0570-T
AAAAA C1155
XX-1µ5 M 275V~
B81130 X2 MKP/SH
40/100/21/C
Bulk (untaped)
Taped (Ammo pack or reel)
For notes on taping,
refer to chapter “Taping and packing”, page 274.
V
D E
IEC 384-14(2)
1)
250 V~
KMK0699-I
Marks of conformity
Marks of
conformity
250 V~
KMK0571-2
Lead spacing = 27,5 mm
(1,5 and 2,2 µF)
Delivery mode
250 V~
Standards
Certificate
EN 132400 / IEC 384-14, 2nd edition
UL 1414 (VR = 250 Vac)
Approved by UL according to
CSA C22.2 No. 0; 1 (V R = 250 Vac)
18643-4670-1010/A1G
E97863/97NK11940A
E97863/97NK11940A
1) Not for 1,5 and 2,2 µF
231 12/00
X2
B 81 130
275 Vac
Ordering codes and packing units
Maximum
dimensions
b×h×l
(mm)
Ordering code1)
Packing units (pcs)
Ammo Reel
Untaped
pack
Lead length
6 mm
26 mm
Lead
spacing
± 0,4
mm
CR
10
10 nF
15 nF
22 nF
33 nF
33 nF
47 nF
4,0 × 9,0 × 13,0
4,0 × 9,0 × 13,0
5,0 × 11,0 × 13,0
5,0 × 11,0 × 13,0
6,0 × 12,0 × 13,0
6,0 × 12,0 × 13,0
B81130-C1103-+*** 1000
B81130-C1153-+*** 1000
B81130-C1223-+***
830
B81130-C1333-M*** 830
B81130-A1333-+***
680
B81130-C1473-+***
680
1700
1700
1300
1300
1100
1100
1000
1000
1000
1000
1000
1000
—
—
—
—
—
—
15
22 nF
33 nF
47 nF
68 nF
0,10 µF
0,10 µF
0,15 µF
0,22 µF
5,0 × 10,5 × 18,0
5,0 × 10,5 × 18,0
5,0 × 10,5 × 18,0
6,0 × 11,0 × 18,0
6,0 × 12,0 × 18,0
7,0 × 12,5 × 18,0
8,5 × 14,5 × 18,0
9,0 × 17,5 × 18,0
B81130-B1223-+*** 1170
B81130-B1333-+*** 1170
B81130-B1473-+*** 1170
B81130-C1683-+***
960
B81130-C1104-M*** 960
B81130-A1104-+***
830
B81130-C1154-+***
680
B81130-C1224-+***
640
1300
1300
1300
1100
1100
900
700
700
1000
1000
1000
1000
1000
1000
500
500
1000
1000
1000
1000
1000
800
500
500
22,5
0,15 µF 6,0 × 15,0 × 26,5
0,22 µF 7,0 × 16,0 × 26,5
0,33 µF 8,5 × 16,5 × 26,5
0,47 µF 10,5 × 16,5 × 26,5
0,47 µF 10,5 × 18,5 × 26,5
0,68 µF 11,0 × 20,5 × 26,5
B81130-B1154-+***
B81130-B1224-+***
B81130-C1334-+***
B81130-C1474-M***
B81130-A1474-+***
B81130-C1684-M***
700
600
500
400
400
350
720
630
510
540
540
510
500
500
450
350
300
300
27,5
0,47 µF
0,68 µF
1,0 µF
1,0 µF
1,5 µF
1,5 µF
2,2 µF
2,2 µF
B81130-B1474-+***
B81130-B1684-+***
B81130-C1105-M***
B81130-A1105-+***
B81130-C1155-M***
B81130-A1155-+***
B81130-C1225-M***
B81130-A1225-+***
350
350
300
250
—
—
—
—
320
320
280
260
240
200
200
180
200
200
200
150
150
100
100
100
11,0 × 21,0 × 31,5
11,0 × 21,0 × 31,5
12,5 × 21,5 × 31,5
13,5 × 23,0 × 31,5
15,0 × 24,5 × 31,5
18,0 × 27,5 × 31,5
18,0 × 27,5 × 31,5
19,0 × 30,0 × 31,5
680
580
480
390
390
370
—
—
—
—
—
—
—
—
Capacitance tolerance: ± 20 % =ˆ M, ± 10 % =ˆ K (closer tolerances upon request)
1) Replace the + by the code letter for the required capacitance tolerance.
Replace the *** by the code number for the required lead length or packing.
000 = lead length 6 mm (untaped)
026 = lead length 26 mm (untaped)
289 = taped, Ammo pack
189 = taped, reel
232 12/00
B 81 130
X2
275 Vac
Technical data
Climatic category
in accordance with IEC 60068-1
40/100/21
Lower category temperature Tmin
Upper category temperature Tmax
− 40 °C
+ 100 °C
Passive flammability category
in accordance with IEC 40 (CO) 752 C
Damp heat test
21 days/40 °C/93 % relative humidity
Limit values after damp
heat test
Capacitance change |∆C/C|
Dissipation factor change ∆ tan δ
Insulation resistance Ris
or time constant τ = C R ⋅ Ris
Permissible
continuous ac voltage
275 V (50/60 Hz)
Permissible continuous dc voltage
560 V
DC test voltage
2121 V, 2 s
Dissipation factor tan δ (in 10−3)
at 20 °C
(upper limit values)
Insulation resistance R is
or time constant τ = CR ⋅ R is
at 20 °C, rel. humidity ≤ 65 %
(minimum as-delivered values)
≤3%
≤ 0,5 ⋅ 10−3 (at 1 kHz)
≤ 1,0 ⋅ 10−3 (at 10 kHz)
≥ 50 % of minimum
as-delivered values
at
CR ≤ 0,1 µF
1 kHz 1,0
100 kHz 5
CR ≤ 0,33 µF
100 GΩ
0,1 µF < CR ≤ 1 µF C R > 1 µF
1,0
10
C R > 0,33 µF
30 000 s
Impedance Z
versus frequency f
(typical values)
233 12/00
1,0
13
X2
B 81 130
275 Vac
Pulse handling capability
Maximum permissible voltage change per unit of time for non-sinusoidal voltages (pulse, sawtooth).
VR
275 Vac
Max. rate of voltage rise V pp/τ in V/µs (for V pp = V
ˆR)
Lead spacing
10 mm
15 mm
22,5 mm
27,5 mm
290
110
50
30
ˆR, the permissible voltage rise rate Vpp/τ may be multiplied by the factor VˆR/Vpp.
For V pp < V
Also refer to the calculation example in chapter “General technical information”, page 302.
VR
275 Vac
Pulse characteristic k 0 in V2/µs (for V pp ≤ V
ˆR)
Lead spacing
10 mm
15 mm
22,5 mm
27,5 mm
220 000
80 000
35 000
21 000
234 12/00
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
 EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
 EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1