MICREL SY100EPT23LZG

Micrel, Inc.
ECL Pro™
SY100EPT23L
ECL Pro™
3.3V DUAL DIFFERENTIAL
LVPECL-to-LVTTL TRANSLATOR
SY100EPT23L
FEATURES
■
■
■
■
■
■
■
3.3V power supply
1.9ns typical propagation delay
Maximum frequency > 275MHz
Differential LVPECL inputs
24mA LVTTL outputs
Flow-through pinouts
Internal input resistors: pulldown on D, pulldown
and pullup on /D
■ Q output will default LOW with inputs open or at
Ground
■ Available in 8-pin MSOP and SOIC packages
ECL Pro™
DESCRIPTION
The SY100EPT23L is a dual differential LVPECL-toLVTTL translator. Because LVPECL (Low Voltage Positive
ECL) levels are used, only +3.3V and ground are required.
The tiny 8-pin MSOP and dual-gate design of the EPT23L
makes it ideal for applications which require the
translation of a clock and data signal.
The EPT23L is available in only the ECL 100K
standard. Since there are no LVPECL outputs or an
external VBB reference, the EPT23L does not require
both ECL standard versions. The inputs can accept 10K
voltage levels and any standard differential LVPECL input
referenced from a VCC of +3.3V
PIN NAMES
Pin
Function
Q0, Q1
LVTTL Outputs
D0, /D0, D1, /D1
Differential LVPECL Inputs
VCC
Positive Supply
GND
Ground
ECL Pro is a trademark of Micrel, Inc.
M9999-120505
[email protected] or (408) 955-1690
Rev.: E
1
Amendment: 0
Issue Date: October 2005
ECL Pro™
SY100EPT23L
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
D0 1
8 VCC
/D0 2
7 Q0
LVPECL
LVTTL
/D1 3
6 Q1
D1 4
5 GND
8-pin SOIC (Z8-1)
8-pin MSOP (K8-1)
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY100EPT23LZC
Z8-1
Commercial
XEP23L
Sn-Pb
SY100EPT23LZCTR(2)
Z8-1
Commercial
XEP23L
Sn-Pb
SY100EPT23LKC
K8-1
Commercial
XP23
Sn-Pb
SY100EPT23LKCTR(2)
K8-1
Commercial
XP23
Sn-Pb
SY100EPT23LZI
Z8-1
Industrial
XEP23L
Sn-Pb
SY100EPT23LZITR(2)
Z8-1
Industrial
XEP23L
Sn-Pb
SY100EPT23LKI
K8-1
Industrial
XP23
Sn-Pb
SY100EPT23LKITR(2)
K8-1
Industrial
XP23
Sn-Pb
SY100EPT23LZG(3)
Z8-1
Industrial
XEP23L with Pb-Free
bar-line indicator
Pb-Free
NiPdAu
SY100EPT23LZGTR(2, 3)
Z8-1
Industrial
XEP23L with Pb-Free
bar-line indicator
Pb-Free
NiPdAu
SY100EPT23LKG(3)
K8-1
Industrial
XP23 with Pb-Free
bar-line indicator
Pb-Free
NiPdAu
SY100EPT23LKGTR(2, 3)
K8-1
Industrial
XP23 with Pb-Free
bar-line indicator
Pb-Free
NiPdAu
Part Number
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-120505
[email protected] or (408) 955-1690
2
ECL Pro™
SY100EPT23L
Micrel, Inc.
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Paramter
TRUTH TABLE
Value
Unit
D
/D
Q
–0.5 to +3.8
V
L
H
L
0V to VCC +0.5
V
H
L
H
Open
Open
L
VCC
Power Supply Voltage
VIN
PECL Input Voltage
VOUT
Voltage Applied to
Output at HIGH State
–0.5 to VCC
V
IOUT
Current Applied to
Output at LOW State
Twice the
Rated IOL
mA
TLead
Lead Temperature
(soldering, 20 sec.)
+260
°C
Tstore
Storage Temperature
–65 to +150
°C
TA
Operating Temperature
–40 to +85
°C
θJA
(Still-air) SOIC
(Still-air) MSOP
160
200
°C/W
°C/W
θJC
SOIC
MSOP
39
39
°C/W
°C/W
Note:
1. Permanent device damage may occur if absolute maximum ratings are
exceeded. This is a stress rating only and functional operation is not
implied at conditions other than those detailed in the operational sections
of this data sheet. Exposure to absolute maximum ratlng conditions for
extended periods may affect device reliability.
LVTTL DC ELECTRICAL CHARACTERISTICS
VCC = 3.3V, GND = 0V.
TA = –40°C
Symbol
Parameter
Voltage(2)
VOH
Output HIGH
VOL
Output LOW Voltage
IOS
Output Short Circuit Current
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Unit
Condition
2.3
—
2.3
—
2.3
—
2.3
—
V
IOH = –3.0mA
—
0.5
—
0.5
—
0.5
—
0.5
V
IOL = 24mA
–80
–240
–80
–240
–80
–240
–80
–240
mA
VOUT = 0V
LVPECL DC ELECTRICAL CHARACTERISTICS
VCC = 3.3V, GND = 0V.
TA = –40°C
Symbol
Parameter
Min.
Typ.
TA = 0°C
Max.
Min.
Typ.
TA = +25°C
Max.
Min.
Typ.
TA = +85°C
Max.
Min.
Typ.
Max.
Unit
ICC
Power Supply Current
—
—
30
—
—
30
—
—
30
—
—
30
mA
IIH
Input HIGH Current
—
—
150
—
—
150
—
—
150
—
—
150
µA
IIL
Input LOW Current
0.5
—
—
0.5
—
—
0.5
—
—
0.5
—
—
µA
VCMR
Common Mode Range
1.5
—
3.3
1.5
—
3.3
1.5
—
3.3
1.5
—
3.3
V
VPP
Minimum Peak-to-Peak
Input(1)
200
—
—
200
—
—
200
—
—
200
—
—
mV
VIH
Input HIGH Voltage(2)
2070
—
2420
2130
—
2460
2135
—
2490
2130
—
2565
mV
VIL
Input LOW Voltage(2)
1350
—
1825
1350
—
1825
1350
—
1825
1350
—
1825
mV
Notes:
1. 200mV input guarantees full logic at output.
2. These values are for VCC = 3.3V. Level Specifications will vary 1:1 with VCC.
M9999-120505
[email protected] or (408) 955-1690
3
ECL Pro™
SY100EPT23L
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
VCC = 3.0V to 3.6V, GND = 0V.
TA = –40°C
Symbol
tPD
tskpp
Parameter
Propagation Delay
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Unit
Condition
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
ns
CL = 20pF
Skew(1,4)
—
0.5
—
0.5
—
0.5
—
0.5
ns
CL = 20pF
Within-Device
Skew(2,4)
—
0.3
—
0.3
—
0.3
—
0.3
ns
CL = 20pF
tskew– –
Within-Device
Skew(3,4)
—
0.3
—
0.3
—
0.3
—
0.3
ns
CL = 20pF
tr
Output Rise/Fall Time
0.5
1.0
0.5
1.0
0.5
1.0
0.5
1.0
ns
CL = 20pF
tf
1.0V to 2.0V
fMAX
Maximum Input Frequency(5,6)
275
—
275
—
275
—
275
—
MHz
CL = 20pF
tskew++
Part-to-Part
TA = 0°C
Notes:
1. Device-to-Device Skew considering HIGH-to-HIGH transitions at common VCC level.
2. Within-Device Skew considering HIGH-to-HIGH transitions at common VCC level.
3. Within-Device Skew considering LOW-to-LOW transitions at common VCC level.
4. All skew parameters are guaranteed but not tested.
5. Frequency at which guaranteed for functionality. VOH and VOL levels are guaranteed at DC only.
6. The fMAX value is specified as the minimum guaranteed maximum frequency. Actual operational maximum frequency may be greater.
M9999-120505
[email protected] or (408) 955-1690
4
ECL Pro™
SY100EPT23L
Micrel, Inc.
8-PIN PLASTIC SOIC (Z8-1)
Rev. 03
M9999-120505
[email protected] or (408) 955-1690
5
ECL Pro™
SY100EPT23L
Micrel, Inc.
8-PIN MSOP (K8-1)
Rev. 01
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2005 Micrel, Incorporated.
M9999-120505
[email protected] or (408) 955-1690
6