MICREL SY88927VZG

Micrel, Inc.
FEATURES
SY88927V
DESCRIPTION
■ 3.3V and 5V power supply options
■ Maximum frequency > 3.0GHz
■ Internal 75KΩ input pull-down resistors
■
■
■
■
SY88927V
5V/3.3V 2.5Gbps
HIGH-SPEED DIFFERENTIAL RECEIVER
The SY88927V is a 2.5Gbps high-speed differential
receiver. The device is functionally equivalent to the
EL16V devices, with higher performance capabilities. With
output transition times significantly faster than the EL16V,
the SY88927V is ideally suited for interfacing with highfrequency sources.
The SY88927V provides a VBB output for either singleended use or as a DC bias for AC coupling to the device.
The V BB pin should be used only as a bias for the
SY88927V as its current sink/source capability is limited.
Whenever used, the VBB pin should be bypassed to the
most positive supply via a 0.01µF capacitor.
Under open input conditions (pulled to VEE), internal
input clamps will force the Q output LOW.
Faster version of SY100EL16V
100K ECL compatible I/O
Improved output waveform characteristics
Available in 8-pin (3mm) MSOP and SOIC package
PIN NAMES
Pin
M9999-092305
[email protected] or (408) 955-1690
Function
D
Data Inputs
Q
Data Outputs
VBB
Reference Voltage Output
Rev.: E
1
Amendment: /0
Issue Date: September 2005
SY88927V
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
Ordering Information
NC 1
8 VCC
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
D 2
7 Q
SY88927VKC
K8-1
Commercial
927V
Sn-Pb
/D 3
6 /Q
SY88927VKCTR(1)
K8-1
Commercial
927V
Sn-Pb
5 VEE
SY88927VZC
Z8-1
Commercial
927V
Sn-Pb
SY88927VZCTR(1)
Z8-1
Commercial
927V
Sn-Pb
SY88927VKG(2)
K8-1
Industrial
927V with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY88927VKGTR(1,2)
K8-1
Industrial
927V with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY88927VZG(2)
Z8-1
Industrial
927V with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY88927VZGTR(1,2)
Z8-1
Industrial
927V with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
VBB
4
10-Pin MSOP (K10-1)
Note:
M9999-092305
[email protected] or (408) 955-1690
1.
Tape and Reel.
2.
NiPdAu Pb-Free package recommended for new designs.
2
SY88927V
Micrel, Inc.
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Rating
Value
Unit
VEE
Power Supply Voltage
–8.0 to 0
V
VI
Input Voltage
0 to –6.0
V
IOUT
Output Current
50
100
mA
TA
Operating Temperature Range
–40 to +85
°C
TLEAD
Lead Temperature (Soldering, 20 sec.)
+260
°C
Tstore
Storage Temperature Range
–65 to +150
°C
–Continuous
–Surge
Note:
1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not implied at
conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum ratlng conditions for extended periods
may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
VEE = –3.0V to –5.5V; VCC = GND
TA = –40°C
Symbol
TA = 0°C
TA = +25°C
TA = +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
IEE
Power Supply Current
—
—
40
—
—
40
—
35
42
—
—
48
mA
VBB
Output Reference
Voltage
IIH
Input HIGH Current
–1.38 –1.30 –1.26 –1.38 –1.31 –1.26 –1.38 –1.32 –1.26 –1.38 –1.33 –1.26
—
—
150
—
—
150
—
—
150
—
—
150
V
µA
100K SERIES DC ELECTRICAL CHARACTERISTICS(1)
VEE = –3.0V to –5.5V; VCC = GND
TA = –40°C
Symbol
TA = 0°C to +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Conditions
VOH
VOL
Output HIGH Voltage
Output LOW Voltage
–1085
–1830
–1005
–1695
–880
–1555
–1025
–1810
–955
–1705
–880
–1620
mV
VIN = VIH(Max)
or VIL(Min)
VOHA
VOLA
Output HIGH Voltage
Output LOW Voltage
–1095
—
—
—
—
–1555
–1035
—
—
—
—
–1610
mV
VIN = VIH(Min)
or VIL(Max)
VIH
Input HIGH Voltage(2)
–1165
—
–880
–1165
—
–880
mV
VIL
Input LOW Voltage(3)
–1810
—
–1475
–1810
—
–1475
mV
IIL
Input LOW Current
0.5
—
—
0.5
—
—
µA
Loading with
50Ω to –2.0V
VIN = VIL(Min)
Notes:
1. This table replaces the three tables traditionally seen in ECL 100K data books. Outputs are terminated through a 50Ω resistor to –2.0V except where
otherwise specified on the individual data sheets.
2. Guaranteed HIGH Signal for all inputs.
3. Guaranteed LOW Signal for all inputs.
M9999-092305
[email protected] or (408) 955-1690
3
SY88927V
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
VEE = –3.0V to –5.5V; VCC = GND
TA = –40°C
Symbol
TA = 0°C
TA = +25°C
TA = +85°C
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
tPLH
tPHL
Propagation Delay to
Output
D (Diff)
D (SE)
150
—
240
—
150
—
240
—
150
—
190
—
240
—
150
—
280
—
tskew
Duty Cycle Skew(1)
—
—
—
20
—
5
20
—
20
VCMR
Common Mode
VPP
Input Voltage Range
tr
tf
(Diff)
Range(2)
Output Rise/Fall Times
(20% to 80%)
(Diff)
Q(3)
Unit
ps
VEE+2 VCC–0.4 VEE+2 VCC–0.4 VEE+2
—
VCC–0.4 VEE+2 VCC–0.4
ps
V
150
1200
150
1200
150
800
1200
150
1200
mV
—
175
—
175
—
105
175
—
175
ps
NOTES:
1. Duty cycle skew is the difference between a tPLH and tPHL propagation delay through a device.
2. The CMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within the specified
range and the peak-to-peak voltage lies between VPP min. and 1V. The lower end of the CMR range varies 1:1 with VEE.
3. VID > 150mV.
M9999-092305
[email protected] or (408) 955-1690
4
SY88927V
Micrel, Inc.
8 LEAD MSOP (K8-1)
Rev. 01
M9999-092305
[email protected] or (408) 955-1690
5
SY88927V
Micrel, Inc.
8 LEAD SOIC .150" WIDE (Z8-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2005 Micrel, Incorporated.
M9999-092305
[email protected] or (408) 955-1690
6