MICREL SY100ELT21ZC

Micrel, Inc.
Precison Edge®
SY10ELT21
Precision
Edge®
SY100ELT21
DIFFERENTIAL
PECL-to-TTL
TRANSLATOR
SY10ELT21
SY100ELT21
FEATURES
„
„
„
„
„
„
2.5ns typical propagation delay
Low power
Differential PECL inputs
24mA TTL outputs
Flow-through pinouts
Available in 8-pin SOIC package
Precision Edge®
DESCRIPTION
The SY10/100ELT21 are single differential PECL-toTTL translators. Because PECL (Positive ECL) levels are
used, only +5V and ground are required. The small outline
8-lead SOIC package and low skew single gate design
make the ELT21 ideal for applications that require the
translation of a clock or data signal where minimal space,
low power, and low cost are critical.
The VBB output allow differential single-ended, or ACcoupled interface to the device. If used, the VBB output
should be bypassed to VCC with a 0.01µF capacitor.
The ELT21 is available in both ECL standards: the
10ELT is compatible with positive ECL 10H logic levels,
while the 100ELT is compatible with positive ECL 100K
logic levels.
PIN NAMES
Pin
Function
Q
TTL Output
D, /D
Differential PECL Inputs
VCC
+5.0V Supply
VBB
Reference Output
GND
Ground
Precision Edge is a registered trademark of Micrel, Inc.
M9999-031506
[email protected] or (408) 955-1690
Rev.: C
1
Amendment: /0
Issue Date: March 2006
Precision Edge®
SY10ELT21
SY100ELT21
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
NC 1
TTL
D 2
Package
Marking
Lead
Finish
SY10ELT21ZC
Z8-1
Commercial
HEL21
Sn-Pb
SY10ELT21ZCTR(2)
Z8-1
Commercial
HEL21
Sn-Pb
SY100ELT21ZC
Z8-1
Commercial
XEL21
Sn-Pb
SY100ELT21ZCTR(2)
Z8-1
Commercial
XEL21
Sn-Pb
SY10ELT21ZI
Z8-1
Industrial
HEL21
Sn-Pb
SY10ELT21ZITR(2)
Z8-1
Industrial
HEL21
Sn-Pb
SY100ELT21ZI
Z8-1
Industrial
XEL21
Sn-Pb
SY100ELT21ZITR(2)
Z8-1
Industrial
XEL21
Sn-Pb
SY10ELT21ZG(3)
Z8-1
Industrial
HEL21 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY10ELT21ZGTR(2, 3)
Z8-1
Industrial
HEL21 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY100ELT21ZG(3)
Z8-1
Industrial
XEL21 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY100ELT21ZG(TR(2, 3)
Z8-1
Industrial
XEL21 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
7 Q
6 NC
VBB 4
Operating
Range
Part Number
PECL
D 3
Package
Type
8 VCC
5 GND
8-Pin SOIC (Z8-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-031506
[email protected] or (408) 955-1690
2
Precison Edge®
SY10ELT21
SY100ELT21
Micrel, Inc.
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Parameter
VCC
Power Supply Voltage
VI
PECL Input Voltage
VO
Voltage Applied to
Output at HIGH State
IO
Current Applied to
Output at LOW State
TLEAD
Lead Temperature
(soldering, 20sec.)
Tstore
TA
TRUTH TABLE
Value
Unit
D
/D
Q
–0.5 to +7.0
V
L
H
L
0V to VCC+0.5
–0.5 to +5.5
V
H
L
H
V
Open
Open
L
Twice the
Rated IOL
mA
+260
°C
Storage Temperature
–65 to +150
°C
Operating Temperature
–40 to +85
°C
NOTE:
1. Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS
are exceeded. This is a stress rating only and functional operation is not
implied at conditions other than those detailed in the operational sections
of this data sheet. Exposure to ABSOLUTE MAXIMUM RATlNG conditions
for extended periods may affect device reliability.
TTL DC ELECTRICAL CHARACTERISTICS
VCC = 4.75V to 5.25V
TA = –40°C
Symbol
TA = 0°C
TA = +25°C
TA = +85°C
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
Condition
IOS
Output Short Circuit Current
–80
–200
–80
–200
–80
—
–200
–80
–200
mA
ICC
Power Supply Current
—
20
—
20
—
14
20
—
20
mA
—
VOH
Output HIGH Voltage
2.5
2.0
—
—
2.5
2.0
—
—
2.5
2.0
—
—
—
—
2.5
2.0
—
—
V
V
IOH = –3.0mA
IOH = –15mA
VOL
Output LOW Voltage
—
0.5
—
0.5
—
—
0.5
—
0.5
V
IOL = 24mA
VOUT = 0V
PECL DC ELECTRICAL CHARACTERISTICS
VCC = 4.75V to 5.25V
TA = –40°C
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
IIH
Input HIGH Current
—
150
—
150
—
—
150
—
150
µA
IIL
Input LOW Current
0.5
—
0.5
—
0.5
—
—
0.5
—
µA
Voltage(2)
VIH
Input HIGH
10ELT
100ELT
3770 4110
3835 4120
3830 4160
3835 4120
3870
3835
—
4190
4120
3940 4280
3835 4120
mV
VIL
Input LOW Voltage(2) 10ELT
100ELT
3050 3500
3190 3525
3050 3520
3190 3525
3050
3190
—
—
3520
3525
3050 3555
3190 3525
mV
VBB
Reference Output(2)
3570 3700
3620 3740
3620 3730
3620 3740
3650
3620
—
—
3750
3740
3690 3810
3620 3740
mV
10ELT
100ELT
NOTE:
2. These values are for VCC = 5.0V. Level Specifications will vary 1:1 VCC.
M9999-031506
[email protected] or (408) 955-1690
3
Condition
Precision Edge®
SY10ELT21
SY100ELT21
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
VCC = 4.75V to 5.25V
TA = –40°C
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
Condition
tPLH
tPHL
Propagation Delay
D to Output Q
2.0
3.0
2.0
3.0
2.0
—
3.0
2.0
3.0
ns
CL = 50pF
tskpp
Part-to-Part Skew(1, 2)
—
0.5
—
0.5
—
—
0.5
—
0.5
ns
CL = 50pF
fMAX
Maximum Input Frequency
160
—
160
—
160
—
—
160
—
MHz
CL = 50pF
VCMR
Common Mode Range
2.4
VCC
2.4
VCC
2.4
—
VCC
2.4
VCC
V
200
—
200
—
200
—
—
200
—
mV
—
1.5
—
1.5
—
—
1.5
—
1.5
ns
(2, 3, 4)
VPP
Minimum Peak-to-Peak
tr
tf
Output Rise/Fall Time
(1.0V to 2.0V)
Input(5)
CL = 50pF
NOTES:
1. Part-to-Part Skew considering HIGH-to-HIGH transitions at common VCC levels.
2. These parameters are guaranteed, but not tested.
3. Frequency at which output levels will meet a 0.8V to 2.0V minimum swing.
4. The fMAX value is specified as the minimum guaranteed maximum frequency. Actual operational maximum frequency may be greater.
5. 200mV input guarantees full logic at output.
M9999-031506
[email protected] or (408) 955-1690
4
Precison Edge®
SY10ELT21
SY100ELT21
Micrel, Inc.
8 LEAD SOIC .150" WIDE (Z8-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its
use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product
can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical
implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user.
A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to
fully indemnify Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-031506
[email protected] or (408) 955-1690
5