MICREL SY100S370JC

UNIVERSAL
DEMULTIPLEXER/
DECODER
Micrel, Inc.
FEATURES
SY100S370
SY100S370
DESCRIPTION
■ Max. propagation delay of 1200ps
■ IEE min. of –92mA
■ Industry standard 100K ECL levels
■ Extended supply voltage option:
VEE = –4.2V to –5.5V
■ Voltage and temperature compensation for improved
noise immunity
■ Internal 75KΩ input pull-down resistors
■ 60% faster than National or Signetics
■ Approximately 40% lower power than Fairchild
■ Function and pinout compatible with Fairchild F100K
■ Available in 24-pin CERPACK and 28-pin PLCC
packages
The SY100S370 is a universal demultiplexer/decoder
that can be used as either a dual 1-of-4 decoder or as a
single 1-of-8 decoder and is designed for use in highperformance ECL systems. The Mode control (M) input
determines the function. In the dual 1-of-4 mode, each 4input group has a pair of active-LOW Enable (E) inputs.
The Enable pins are assigned such that in the single 1-of8 mode they can be tied together in pairs to result in two
active-LOW Enable inputs. E1a will be tied to E1b and E2a
to E2b.
The auxiliary inputs (Hn) are used to determine whether
the outputs are active-HIGH or active-LOW. The address
inputs for the dual 1-of-4 mode are A0a, A1a, A0b. A2a is
unused. In the 1-of-8 mode, the address inputs are A0a,
A1a, A2a. The inputs on the device have 75KΩ pull-down
resistors.
PIN NAMES
Pin
Function
Ana, Anb
Address Inputs (n = 0,1,2)
Ena, Enb
Enable Inputs (n = 1,2)
M
Mode Control Input
Ha
Z0 – Z3 (Z0a – Z3a) Polarity Select Input
Hb
Z4 – Z7 (Z0b – Z3b) Polarity Select Input
Hc
Common Polarity Select Input
Z0 – Z7
Single 1-of-8 Data Outputs
Zna, Znb
Dual 1-of-4 Data Outputs (n = 1...4)
VEES
VEE Substrate
VCCA
VCCO for ECL Outputs
M9999-032406
[email protected] or (408) 955-1690
1
Rev.: H
Amendment: /0
Issue Date: March 2006
SY100S370
Micrel, Inc.
Z1a (Z1)
Z2a (Z2)
A0a
M
A1a
VEES
A2a
PACKAGE/ORDERING INFORMATION
Ordering Information
11 10 9 8 7 6 5
E1a
E1b
VEE
12
13
14
15
16
17
18
VEES
E2b
E2a
Ha
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY100S370FC
F24-1
Commercial
SY100S370FC
Sn-Pb
SY100S370FCTR(1)
F24-1
Commercial
SY100S370FC
Sn-Pb
SY100S370JC
J28-1
Commercial
SY100S370JC
Sn-Pb
SY100S370JCTR(1)
J28-1
Commercial
SY100S370JC
Sn-Pb
SY100S370JZ(2)
J28-1
Commercial
SY100S370JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100S370JZTR(1, 2)
J28-1
Commercial
SY100S370JZ with
Pb-Free bar-line indicator
Matte-Sn
Part Number
4
3
2
1
28
27
26
Top View
PLCC
J28-1
Z0a (Z0)
Z3a (Z3)
VCCA
VCC
VCC
Z1b (Z5)
Z2b (Z6)
A1b
Z3b (Z7)
Z0b (Z4)
VEES
Hb
A0b
Hc
19 20 21 22 23 24 25
Notes:
1. Tape and Reel.
2. Pb-Free package is recommended for new designs.
E1a
E1b
E2a
E2b
VEE
Ha
28-Pin PLCC (J28-1)
Hc
1
24 23 22 21 20 19
18
A2a
Hb
2
3
17
16
M
A1a
15
14
A0a
Z1a (Z1)
13
7 8 9 10 11 12
Z2a (Z2)
Z0b (Z4)
6
Z3a (Z3)
Z0a (Z0)
4
5
Z2b (Z6)
Z3b (Z7)
Top View
Flatpack
F24-1
Z1b (Z5)
VCC
VCCA
A0b
A1b
24-Pin Cerpack (F24-1)
M9999-032406
[email protected] or (408) 955-1690
2
SY100S370
Micrel, Inc.
BLOCK DIAGRAM
A0a
Z2a (Z2)
A1a
Z0a (Z0)
E1a
E2a
Z1a (Z1)
A2a
M
Z3a (Z3)
Z2b (Z6)
A0b
Z0b (Z4)
Z1b (Z5)
Z3b (Z7)
A1b
E1b
E2b
Ha
Hc
Hb
M9999-032406
[email protected] or (408) 955-1690
3
SY100S370
Micrel, Inc.
TRUTH TABLES(1)
Dual 1-of-4 Mode (M = A2a = Hc = LOW)
Active HIGH Outputs
(Ha and Hb Inputs HIGH)
Inputs
Active LOW Outputs
(Ha and Hb Inputs LOW)
E1a,E1b
E2a,E2b
A1a,A1b
A0a,A0b
Z0a,Z0b
Z1a,Z1b
Z2a,Z2b
Z3a,Z3b
Z0a,Z0b
Z1a,Z1b
Z2a,Z2b
Z3a,Z3b
H
X
L
L
X
H
L
L
X
X
L
L
X
X
L
H
L
L
H
L
L
L
L
H
L
L
L
L
L
L
L
L
H
H
L
H
H
H
H
L
H
H
H
H
H
H
H
H
L
L
L
L
H
H
L
H
L
L
L
L
H
L
L
H
H
H
H
H
L
H
H
L
Single 1-of-8 Mode (M = HIGH; A0b = A1b = Ha = Hb = LOW)
Inputs
Active HIGH Outputs* (Hc Input HIGH)
E1
E2
A2a
A1a
A0a
Z0
Z1
Z2
Z3
Z4
Z5
Z6
Z7
H
X
X
H
X
X
X
X
X
X
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
H
L
H
L
H
H
L
L
L
L
H
L
L
L
L
H
L
L
L
L
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
H
H
H
L
L
H
H
L
H
L
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
L
L
L
L
H
L
L
L
L
H
L
L
L
L
H
Note:
1. H = HIGH Voltage Level
L = LOW Voltage Level
X = Don't Care
* for Hc = LOW, output states are complemented
E1 = E1a and E1b wired; E2 = E2a and E2b wired
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
Symbol
IIH
IEE
Parameter
Input HIGH Current
Hc, A0a, A1a, A2a
All Others
Power Supply Current
M9999-032406
[email protected] or (408) 955-1690
Min.
Typ.
Max.
—
—
—
—
310
250
–92
–73
–46
4
Unit
Condition
µA
VIN = VIH (Max.)
mA
Inputs Open
SY100S370
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
CERPACK
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
Ena, Enb to Output
300
1300
300
1300
300
1300
ps
tPLH
tPHL
Propagation Delay
Ana, Anb to Output
500
1600
500
1600
500
1600
ps
tPLH
tPHL
Propagation Delay
Ha, Hb, Hc to Output
500
1600
500
1600
500
1600
ps
tPLH
tPHL
Propagation Delay
M to Output
600
2100
600
2100
600
2100
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
Condition
PLCC
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
Ena, Enb to Output
300
1200
300
1200
300
1200
ps
tPLH
tPHL
Propagation Delay
Ana, Anb to Output
500
1500
500
1500
500
1500
ps
tPLH
tPHL
Propagation Delay
Ha, Hb, Hc to Output
500
1500
500
1500
500
1500
ps
tPLH
tPHL
Propagation Delay
M to Output
600
2100
600
2100
600
2100
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
M9999-032406
[email protected] or (408) 955-1690
5
Condition
SY100S370
Micrel, Inc.
TIMING DIAGRAM
0.7 ± 0.1 ns
0.7 ± 0.1 ns
–0.95V
INPUT
80%
50%
20%
–1.69V
tPHL
tPLH
80%
50%
20%
OUTPUT
tTLH
tTHL
Propagation Delay and Transition Times
Note:
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
M9999-032406
[email protected] or (408) 955-1690
6
SY100S370
Micrel, Inc.
24-PIN CERPACK (F24-1)
Rev. 03
M9999-032406
[email protected] or (408) 955-1690
7
SY100S370
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032406
[email protected] or (408) 955-1690
8