Features Regulated Converters ● ● ● ● ● ● POWERLINE Compact AC-DC Power Supply 40 Watt PCB Mount Package Universal Input Voltage Range 4000VAC Isolation Low Output Ripple and Noise Short Circuit Protected AC/DC-Converter RAC40S_D_TA Series Selection Guide Input Range (VAC) Output Voltage (VDC) Output Current (mA) Efficiency RAC40-3.3SA 85-264 3.3 8000 75 RAC40-05SA 85-264 5 8000 79 RAC40-09SA 85-264 9 4444 82 RAC40-12SA 85-264 12 3333 83 RAC40-15SA 85-264 15 2666 83 RAC40-24SA 85-264 24 1666 83 RAC40-05DA 85-264 ±5 ±4000 79 RAC40-12DA 85-264 ±12 ±1666 83 RAC40-15DA 85-264 ±15 ±1320 83 RAC40-0512DA 85-264 5/12 5000/1250 80 RAC40-0524DA 85-264 5/24 5000/625 80 RAC40-0512TA 85-264 5/±12 +5000/±600 80 RAC40-0515TA 85-264 5/±15 +5000/±500 80 (%) Specifications ( typical at 25°C, nominal input voltage and after warm up time unless otherwise specified ) Input Voltage Range UL-60601 Certified 90-264VAC or 100-370VDC Rated Power 40 Watts max. Input Frequency Range (for AC Input) 47-440Hz Input Current (full load) 860mA max. (115VAC) / 460mA max. (230VAC) Inrush Current (<2ms) 20A max. (115VAC) / 30A max. (230VAC) Leakage Current Output Voltage Accuracy (Full load) 40 Watt Single, Dual & Triple Output 0.2mA max. Single, Dual Outputs ±1% max. Others: Main Output ±3% max., Secondary Output(s) ±5% max. Line Voltage Regulation (low line, high line at full load) - See Note 1 ±0.5% max. Load Voltage Regulation ( 10% to 100% symmetric load ) - See Note 2 Cross Regulation (Dual, Triple Outputs) ±1% max. 1% Vout max. Operating Frequency 132kHz typ. Isolation Voltage (input to output) 4000VAC min. Temperature Coefficient ±0.01%/°C typ. Isolation Resistance Derating Graph (Ambient Temperature) 125 100 MΩ min. Short Circuit Protection Continuous, Automatic Restart Overcurrent Protection 105% typ. Over Temeperature Protection 100°C Operating Temperature Range (free air convection, with derating) -25°C to +70°C Storage Temperature Range -40°C to +100°C Humidity 95% RH max. Case Material Epoxy with Fibreglass (UL94V-0) Package Weight www.recom-international.com Compact switching power module for PCB or DIN-rail mounting with medical certification UL60601-1. Main Outputs ±5%, Secondary Outputs ±7% typ. Output Ripple and Noise (20MHz limited) - See Note 3 MTBF (+25°C) Description 280g using MIL-HDBK-217F 100 Output Power (%) Part Number Natural Convection 75 50 25 0 -25 -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) 200~400 x 103 hours 12-February-2007 1 RAC40-S_D_TB Series POWERLINE AC/DC-Converter Simplified Schematics L +5Vout +Vout +5V Rtn Rectifier Filter +Vout -Vout N L Line Filter N Com Rectifier FG -Vout Overcurrent Protection PWM Controller Isolation Reference & Error AMP L FG +Vout Rectifier Filter PWM Controller Overcurrent Protection Isolation Reference & Error AMP Com -Vout N Notes FG Overcurrent Protection PWM Controller Isolation Reference & Error AMP Note 1: Line Regulation = 5% max. for Auxilary Outputs Note 2: Load Regulation = 7% max. for Auxilary Outputs Note 3: Ripple & Noise measured with 20MHz BW probe and 0.1µF + 47µF capacitors in parallel across the outputs. Ripple and Noise = 50mV typ. for 3.3V Output. Package Style and Pinning 3rd angle projection 89.00 63.50 27.00 10.0 1.0 81.30 Pin Connections 7 2 15.24 6 12.70 55.88 Bottom View 5 12.70 4 15.24 1 2 3 Pin # Single Out Dual Out 5/12(15) Triple Out 1 VAC in (L) VAC in (L) VAC in (L) VAC in (L) 2 VAC in (N) VAC in (N) VAC in (N) VAC in (N) 3 +VDC out +VDC out +12V(15V) +12V(15V) 4 No Pin No Pin +5V Out 5 -VDC out Com +12V(15V) Rtn 6 No Pin No Pin +5V Rtn +5V Rtn 7 NC -VDC out No Pin -12V(15V) +5V Out Com Tolerance =± 0.5 mm 12-February-2007 www.recom-international.com