R2051 SERIES 2 wire interface Real-Time Clock ICs with Battery Backup switch-over Function NO.EA-104-070626 OUTLINE The R2051 is a CMOS real-time clock IC connected to the CPU by two signal lines, SCL and SDA, and configured to perform serial transmission of time and calendar data to the CPU. Further, battery backup switchover circuit and a voltage detector are incorporated. The periodic interrupt circuit is configured to generate interrupt signals with six selectable interrupts ranging from 0.5 seconds to 1 month. The 2 alarm interrupt circuits generate interrupt signals at preset times. As the oscillation circuit is driven under constant voltage, fluctuation of the oscillator frequency due to supply voltage is small, and the time keeping current is small (TYP. 0.4µA at 3V). The oscillation halt sensing circuit can be used to judge the validity of internal data in such events as power-on; The supply voltage monitoring circuit is configured to record a drop in supply voltage below two selectable supply voltage monitoring threshold settings. The 32.768kHz clock output function (CMOS output) is intended to output sub-clock pulses for the external microcomputer. The oscillation adjustment circuit is intended to adjust time counts with high precision by correcting deviations in the oscillation frequency of the quartz crystal unit. Battery backup switchover function is the automatic switchover circuit between a main power supply and a backup battery of primary or secondary battery. Switchover is executed by monitoring the voltage of a main power supply, therefore the voltage of a backup battery voltage is not relevant. Since the package for these ICs is SSOP16 (5.0x6.4x1.25: R2051Sxx), FFP12 (2.0x2.0x1.0: R2051Kxx), or TSSOP10G (4.0x2.9x1.0: R2051Txx), high density mounting of ICs on boards is possible. FEATURES • • • • • • • • • • • • • • • • • Minimum Timekeeping supply voltage Typ. 0.75V (Max. 1.00V); VDD pin Low power consumption 0.4µA TYP (1.0µA MAX.) at VDD=3V Built-in Backup switchover circuit (can be used for a primary battery, a secondary battery, or an electric double layer capacitor) Only two signal lines (SCL and SDA) required for connection to the CPU. ( I2C-Bus Interface, 400kHz) Time counters (counting hours, minutes, and seconds) and calendar counters (counting years, months, days, and weeks) (in BCD format) Interrupt circuit configured to generate interrupt signals (with interrupts ranging from 0.5 seconds to 1 month) to the CPU and provided with an interrupt flag and an interrupt halt (except R2051Txx) 2 alarm interrupt circuits (Alarm_W for week, hour, and minute alarm settings and Alarm_D for hour and minute alarm settings) (except R2051Txx) Built-in voltage detector with delay With Power-on flag to prove that the power supply starts from 0V 32-kHz clock output pin (CMOS output. “H” level is always equal to VCC.) Supply voltage monitoring circuit with two supply voltage monitoring threshold settings Automatic identification of leap years up to the year 2099 Selectable 12-hour and 24-hour mode settings High precision oscillation adjustment circuit Built-in oscillation stabilization capacitors (CG and CD) CMOS process Package SSOP16 (5.0mm x 6.4mm x 1.25mm : R2051Sxx), FFP12 (2.0mm x 2.0mm x 1.0mm : R2051Kxx) TSSOP10G (4.0x2.9x1.0: R2051Txx) 1 R2051 Series PIN CONFIGURATION R2051Sxx(SSOP16) R2051Kxx(FFP12) SCL 4 13 OSCIN SDA 5 12 OSCOUT NC 6 11 NC VDCC 7 10 INTR VSS 8 9 VSB 1 10 VCC CLKOUT 2 9 VDD CIN 10 6 VDD SCL 3 8 OSCIN VSS 11 5 VCC SDA 4 7 OSCOUT VDCC 12 4 VSB VSS 5 6 CIN CIN TOP VIEW 3 NC CLKOUT 14 2 3 SCL CLKOUT 1 VDD SDA 15 7 2 8 VSB OSCIN VCC OSCOUT 16 9 1 INTR NC R2051Txx(TSSOP10G) TOP VIEW TOP VIEW BLOCK DIAGRAM CPU POWER SUPLLY VDD C2 SW2 SW1 VSB VCC BATTERY VOLTAGE MONITOR R1 VOLTAGE DETECTOR DELAY OSCOUT CIN C1 VOLTAGE REFERENCE VSS ( ) are for the R2051Txx only 2 LEVEL SHIFTER REAL TIME CLOCK OSCIN C3 VDCC (NC) SCL SDA CLKOUT INTR (NC) CPU R2051 Series SELECTION GUIDE In the R2051xxx Series, output voltage and options can be designated. Part Number is designated as follows: R2051K01-E2 ←Part Number ↑↑ ↑ R2051abb-cc Code a bb cc Part Number R2051K01-E2 R2051K02-E2 R2051S01-E2 R2051S02-E2 R2051S03-E2 R2051T01-E2 Description Designation of the package. K: FFP12 S: SSOP16 T: TSSOP10G Serial number of Voltage detector setting etc. Designation of the taping type. Only E2 is available. Package FFP12 FFP12 SSOP16 SSOP16 SSOP16 TSSOP10G -VDET1 (switch-over threshold) 2.40(Typ.) 2.80(Typ.) 2.40(Typ.) 2.80(Typ,) 4.00(Typ.) 2.40(Typ.) DC Electrical Characteristics P.6 P.7 P.6 P.7 P.8 P.6 3 R2051 Series PIN DESCRIPTION PIN R2051Kxx R2051Sxx R2051Txx (FFP12) 4 (SSOP16) Symbol Item Description (TSSOP10G) 2 4 3 SCL Serial Clock Line 1 5 4 SDA Serial Data Line 9 10 - INTR Interrupt Output 3 3 2 CLKOUT 5 16 10 VCC 4 2 1 VSB 7 13 8 OSCIN 8 12 7 OSCOUT 6 15 9 VDD Positive Power Supply Input 12 7 - VDCC VCC Power Supply Monitoring Result Output 10 9 6 CIN Noise Bypass Pin 11 8 5 VSS - 1,6, 11,14 - Negative Power Supply Input NC 32kHz Clock Output Main Battery input Power Supply Input for Backup Battery Oscillation Circuit Input / Output The SCL pin is used to input clock pulses synchronizing the input and output of data to and from the SDA pin. Allows a maximum input voltage of 5.5 volts regardless of supply voltage. The SDA pin is used to input or output data intended for writing or reading in synchronization with the SCL pin. Up to 5.5v beyond VDD may be input. This pin functions as an Nch open drain output. The INTR pin is used to output alarm interrupt (Alarm_W) and alarm interrupt (Alarm_D) and output periodic interrupt signals to the CPU. Disabled at power-on from 0V. Nch. open drain output. The CLKOUT pin is used to output 32.768-kHz clock pulses. CMOS output. “H” level is always equal to VCC. Supply power to the IC. Connect a primary battery for backup. Normally, power is supplied from VCC to the IC. If VCC level is equal or less than –VDET1, power is supplied from this pin. The OSCIN and OSCOUT pins are used to connect the 32.768-kHz quartz crystal unit (with all other oscillation circuit components built into the R2051). The VDD pin is connected to the power supply. Connect a capacitor as much as 0.1µF between VDD and VSS. In the case of using a secondary battery, connecting the secondary battery to this pin is possible. While monitoring VCC Power supply, if the voltage is equal or lower than –VDET1, this output level is “L”. When VDCC becomes “L”, SW1 turns off and SW2 turns on. As a result, power is supplied from VSB pin to the internal real time clock. When VCC is equal to +VDET1 or more, SW1 turns on and SW2 turns off. After t DELAY passed, VDCC output becomes off, or “H”.ch Open-drain output. To stabilize the internal reference, connect a capacitor as much as 0.1µF between this pin and VSS. The VSS pin is grounded. No Connection R2051 Series ABSOLUTE MAXIMUM RATINGS (VSS=0V) Symbol Item VCC Supply Voltage 1 VDD Supply Voltage 2 VSB Supply Voltage 3 VI Input Voltage 1 Input Voltage 2 VO Output Voltage 1 Output Voltage 2 IOUT Maximum Output Current PD Power Dissipation Topt Operating Temperature Tstg Storage Temperature Pin Name VCC VDD VSB SCL, SDA CIN INTR , VDCC *1) CLKOUT VDD Topt = +25°C Description -0.3 to +6.5 -0.3 to +6.5 -0.3 to +6.5 -0.3 to +6.5 -0.3 to VDD+0.3 -0.3 to +6.5 -0.3 to VCC+0.3 10 300 -40 to +85 -55 to +125 Unit V V V V V V V mA mW °C °C *1) Except R2051Txx RECOMMENDED OPERATING CONDITIONS Symbol Vaccess Item Supply Voltage VCLK Minimum Timekeeping Voltage CGout,CDout=0pF *2), *3) Oscillation Frequency Pull-up Voltage fXT VPUP Pin Name VCC power supply voltage for interfacing with CPU (VSS=0V, Topt=-40 to +85°C) Min, Typ. Max. Unit -VDET1 5.5 V *1) 0.75 1.00 V 5.5 kHz V 32.768 INTR , VDCC *4) *1) -VDET1 in Vaccess specification is guaranteed by design. *2) CGout is connected between OSCIN and VSS, CDout is connected between OSCOUT and VSS. R2051 series incorporates the capacitors between OSCIN and VSS, between OSCOUT and VSS. Then normally, CGout and CDout are not necessary. *3) Quartz crystal unit: CL=6-8pF, R1=30KΩ *4) Except R2051Txx 5 R2051 Series DC ELECTRICAL CHARACTERISTICS • R2051K01, R2051S01, R2051T01 (Unless otherwise specified: VSS=0V,VCC=VSB=3.0V, 0.1uF between VDD and VSS, CIN and VSS, Topt=-40 to +85°C) Symbol Item Pin Name Conditions Min. Typ. Max. VIH “H” Input Voltage 0.8x 5.5 SCL,SDA VCC VIL “L” Input Voltage -0.3 0.2x VCC IOH “H” Output CLKOUT VOH=VCC-0.5V -0.5 Current VOL=0.4V “L” Output IOL1 CLKOUT 0.5 Current 2.0 IOL2 *2) INTR IOL4 SDA 3.0 VDD,VSB,VCC=2.0V IOL3 *2) 0.5 VDCC VOL=0.4V IIL Input Leakage SCL VI=5.5V or VSS -1.0 1.0 Current IOZ1 Output Off-state SDA VO=5.5V or VSS -1.0 1.0 Current 1 IOZ2 *2) Output Off-state -1.0 1.0 VO=5.5V or VSS INTR , Current 2 VDCC ISB Time Keeping Current VSB VCC=0V, VSB=3.0V, 0.4 1.0 at Backup mode VDD, Output=OPEN Time keeping ISBL Leakage Current of VSB VCC=3.0V, -1.00 1.00 Backup pin at VSB=5.5V or 0V, VCC_on VDD, Output=OPEN VDETH Supply Voltage VDD 1.90 2.10 2.30 Topt=+25°C Monitoring Voltage “H” VDETL Supply Voltage VDD 1.20 1.35 1.50 Topt=+25°C Monitoring Voltage “L” -VDET1 Detector Threshold VCC 2.34 2.40 2.46 Topt=+25°C Voltage (falling edge of VCC) +VDET1 Detector Released VCC 2.44 2.52 2.60 Topt=+25°C Voltage (rising edge of VCC) Detector Threshold VCC, Topt=-40 to +85°C ±100 ∆VDET and Released Voltage VSB *1) ∆Topt Temperature coefficient VDDOUT1 VDD Output VDD VCC VCC Topt=+25°C, VCC=3.0V, Voltage 1 -0.12 -0.04 Iout=1.0mA VDDOUT2 VDD Output VDD VSB VSB Topt=+25°C, VCC=2.0V, Voltage 2 -0.08 -0.02 VSB=3.0V, Iout=0.1mA CG Internal Oscillation OSCIN 10 Capacitance 1 CD Internal Oscillation OSCOUT 10 Capacitance 2 *1) Guaranteed by design. *2) Except R2051T01 6 Unit V mA mA µA µA µA µA µA V V V V ppm /°C V V pF R2051 Series • R2051K02, R2051S02 (Unless otherwise specified: VSS=0V,VCC=3.3V, VSB=3.0V, 0.1uF between VDD and VSS, CIN and VSS, Topt=-40 to +85°C) Symbol Item Pin Name Conditions Min. Typ. Max. VIH “H” Input Voltage 0.8x 5.5 SCL,SDA VCC VIL “L” Input Voltage -0.3 0.2x VCC IOH “H” Output CLKOUT VOH=VCC-0.5V -0.5 Current VOL=0.4V “L” Output IOL1 CLKOUT 0.5 Current 2.0 IOL2 INTR IOL4 SDA 3.0 VDD,VSB,VCC=2.0V IOL3 0.5 VDCC VOL=0.4V IIL Input Leakage SCL VI=5.5V or VSS -1.0 1.0 Current IOZ1 Output Off-state SDA VO=5.5V or VSS -1.0 1.0 Current 1 IOZ2 Output Off-state -1.0 1.0 VO=5.5V or VSS INTR , Current 2 VDCC ISB Time Keeping Current VSB VCC=0V, VSB=3.0V, 0.4 1.0 at Backup mode VDD, Output=OPEN Time keeping ISBL Leakage Current of VSB VCC=3.3V, -1.00 1.00 Backup pin at VSB=5.5V or 0V, VCC_on VDD, Output=OPEN VDETH Supply Voltage VDD 1.90 2.10 2.30 Topt=+25°C Monitoring Voltage “H” VDETL Supply Voltage VDD 1.20 1.35 1.50 Topt=+25°C Monitoring Voltage “L” -VDET1 Detector Threshold VCC 2.73 2.80 2.87 Topt=+25°C Voltage (falling edge of VCC) +VDET1 Detector Released VCC 2.85 2.94 3.03 Topt=+25°C Voltage (rising edge of VCC) Detector Threshold VCC, Topt=-40 to +85°C ±100 ∆VDET and Released Voltage VSB *1) ∆Topt Temperature coefficient VDDOUT1 VDD Output VDD VCC VCC Topt=+25°C, VCC=3.3V, Voltage 1 -0.12 -0.04 Iout=1.0mA VDDOUT2 VDD Output VDD VSB VSB Topt=+25°C, VCC=2.0V, Voltage 2 -0.08 -0.02 VSB=3.3V, Iout=0.1mA CG Internal Oscillation OSCIN 10 Capacitance 1 CD Internal Oscillation OSCOUT 10 Capacitance 2 *1) Guaranteed by design. Unit V mA mA µA µA µA µA µA V V V V ppm /°C V V pF 7 R2051 Series • R2051S03 (Unless otherwise specified: VSS=0V, VCC=5.0V, VSB=3.0V, 0.1uF between VDD and VSS, CIN and VSS, Topt=-40 to +85°C) Symbol Item Pin Name Conditions Min. Typ. Max. VIH “H” Input Voltage 0.8x 5.5 SCL,SDA VCC VIL “L” Input Voltage -0.3 0.2x VCC IOH “H” Output CLKOUT VOH=VCC-0.5V -0.5 Current VOL=0.4V “L” Output IOL1 CLKOUT 0.5 Current 2.0 IOL2 INTR IOL4 SDA 3.0 VDD,VSB,VCC=2.0V IOL3 0.5 VDCC VOL=0.4V IIL Input Leakage SCL VI=5.5V or VSS -1.0 1.0 Current IOZ1 Output Off-state SDA VO=5.5V or VSS -1.0 1.0 Current 1 IOZ2 Output Off-state -1.0 1.0 VO=5.5V or VSS INTR , Current 2 VDCC ISB Time Keeping Current VSB VCC=0V, VSB=3.0V, 0.4 1.0 at Backup mode VDD, Output=OPEN Time keeping ISBL Leakage Current of VSB VCC=5.0V, -1.00 1.00 Backup pin at VSB=5.5V or 0V, VCC_on VDD, Output=OPEN VDETH Supply Voltage VDD 1.90 2.10 2.30 Topt=+25°C Monitoring Voltage “H” VDETL Supply Voltage VDD 1.20 1.35 1.50 Topt=+25°C Monitoring Voltage “L” -VDET1 Detector Threshold VCC 3.90 4.00 4.10 Topt=+25°C Voltage (falling edge of VCC) +VDET1 Detector Released VCC 4.07 4.20 4.33 Topt=+25°C Voltage (rising edge of VCC) Detector Threshold VCC, Topt=-40 to +85°C ±100 ∆VDET and Released Voltage VSB *1) ∆Topt Temperature coefficient VDDOUT1 VDD Output VDD VCC VCC Topt=+25°C, VCC=5.0V, Voltage 1 -0.12 -0.04 Iout=1.0mA VDDOUT2 VDD Output VDD VSB VSB Topt=+25°C, VCC=2.0V, Voltage 2 -0.08 -0.02 VSB=3.0V, Iout=0.1mA CG Internal Oscillation OSCIN 10 Capacitance 1 CD Internal Oscillation OSCOUT 10 Capacitance 2 *1) Guaranteed by design. 8 Unit V mA mA µA µA µA µA µA V V V V ppm /°C V V pF R2051 Series AC ELECTRICAL CHARACTERISTICS Unless otherwise specified: VSS=0V,Topt=-40 to +85°C Input and Output Conditions: VIH=0.8×VCC,VIL=0.2×VCC,VOH=0.8×VCC,VOL=0.2×VCC,CL=50pF Sym Item CondiVCC≥2.5V *1) VCC≥1.7V *1) -bol Tions Min. Typ. Max. Min. Typ. Max. fSCL SCL Clock Frequency 100 400 tLOW SCL Clock Low Time 4.7 1.3 tHIGH SCL Clock High Time 4.0 0.6 tHD;STA Start Condition Hold 4.0 0.6 Time tSU;ST Stop Condition Set Up 4.0 0.6 Time O tSU;STA Start Condition Set Up 4.7 0.6 Time tSU;DAT Data Set Up Time 250 200 tHD;DA Data Hold Time 0 0 Unit kHz µs µs µs µs µs ns ns T SDA “L” Stable Time 2.0 0.9 µs After Falling of SCL tPZ;DAT SDA off Stable Time 2.0 0.9 µs After Falling of SCL tR Rising Time of SCL 1000 300 ns and SDA (input) tF Falling Time of SCL 300 300 ns and SDA (input) tSP Spike Width that can 50 50 ns be removed with Input Filter tRCV Recovery Time from 62 62 µs Stop Condition to Start Condition Time tDELAY 100 105 110 100 105 110 ms Output Delay Time of Keeping *2) Voltage Detector *1) VCC voltage interfacing with CPU is defined by Vaccess (P.5 RECOMMENDED OPERATING CONDITIONS) *2) Except R2051Txx *) For reading/writing timing, see “P.34 Interfacing with the CPU •Data Transmission under Special Condition”. tPL;DAT 9 R2051 Series Sr S P SCL tLOW tHIGH tHD;STA tSP SDA(IN) tHD;STA tSU;DAT tHD;DAT SDA(OUT) tPL;DAT S Start Condition Sr Repeated Start Condition VCC tPZ;DAT P +VDET1 tDELAY VDCC 10 Stop Condition tSU;STA tSU;STO R2051 Series PACKAGE DIMENSIONS R2051Kxx 9 7 6 10 1PIN INDEX 12 0.2±0.15 0.35 0.25 1.0Max 2.0±0.1 3 2PIN INDEX 0.35 0.3±0.15 0.103 0.5 0.05 4 1 0.5 • (BOTTOM VIEW) 0.17±0.1 0.27±0.15 2.0±0.1 unit: mm 11 R2051 Series • R2051Sxx 0 to 10° 1 8 0.5±0.3 9 4.4±0.2 16 6.4±0.3 5.0±0.3 0.15 +0.1 -0.05 1.15±0.1 0.65 0.1±0.1 0.225typ 0.10 +0.1 0.22 -0.05 0.15 M unit: mm 12 R2051 Series R2051Txx 0 to 10° 1 5 0.5 +0.1 0.15 M +0.1 0.1 -0.05 (0.75) 0.13 -0.05 0.1 0.2±0.1 0.55±0.2 6 0.85±0.15 10 4.0±0.2 2.9±0.2 2.8±0.2 • unit: mm 13 R2051 Series GENERAL DESCRIPTION • Battery Backup Switchover Function The R2051 has two power supply input, or VCC and VSB. With monitoring input voltage of VCC pin by internal Voltage Detector, it is selected which power supply of VCC or VSB is used for the internal power source. Refer to the next table to see the state of the backup battery and internal power supply’s state of the IC by each condition. VCC≥VDET1 VCC<VDET1 VCC→RTC, VDD VSB→RTC, VDD VDCC =OFF(H) (except R2051Txx) VDCC =L (except R2051Txx) As a backup battery, not only a primary battery such as CR2025, LR44, or a secondary battery such as ML614, TC616, but also an electric double layered capacitor or an aluminum capacitor can be used. Switchover point is judged with the voltage of the main power (VCC), therefore, if the backup voltage is higher than main supply voltage, switchover can be realized without extra load to the backup power supply. The case of back-up by primary battery VCC CPU Power Supply VSB VDD The case of back-up by capacitor or secondary battery (Charging voltage is equal to CPU power supply voltage) VCC VCC VSB VDD VDD 5V Double layer capacitor etc. ML614 etc. VSS CPU power supply (3V) 0.1 µF 0.1 µF CR2025 etc. • CPU power supply VSB 0.1µF VSS The case of back-up by capacitor or secondary battery (Charging voltage is not equal to CPU power supply voltage) VSS Interface with CPU The R2051 is connected to the CPU by two signal lines SCL and SDA, through which it reads and writes data from and to the CPU. Since the output of the I/O pin of SDA is open drain, data interfacing with a CPU different supply voltage is possible by applying pull-up resistors on the circuit board. The maximum clock frequency of 400kHz (at VDD=3V) of SCL enables data transfer in I2C-Bus fast mode. VCC falls down under -VDET1, the R2051 stops accessing with CPU. • Clock and Calendar Function The R2051 reads and writes time data from and to the CPU in units ranging from seconds to the last two digits of the calendar year. The calendar year will automatically be identified as a leap year when its last two digits are a multiple of 4. Consequently, leap years up to the year 2099 can automatically be identified as such. *) The year 2000 is a leap year while the year 2100 is not a leap year. 14 R2051 Series • Alarm Function The R2051 incorporates the alarm interrupt circuit configured to generate interrupt signals to the CPU at preset times. The alarm interrupt circuit allows two types of alarm settings specified by the Alarm_W registers and the Alarm_D registers. The Alarm_W registers allow week, hour, and minute alarm settings including combinations of multiple day-of-week settings such as "Monday, Wednesday, and Friday" and "Saturday and Sunday". The Alarm_D registers allow hour and minute alarm settings. The Alarm_W outputs from INTR pin, and the Alarm_D outputs also from INTR pin. Each alarm function can be checked from the CPU by using a polling function. R2051Txx has Alarm_D and Alarm_W registers, but does not have INTR output pin. • High-precision Oscillation Adjustment Function The R2051 has built-in oscillation stabilization capacitors (CG and CD), that can be connected to an quartz crystal unit to configure an oscillation circuit. Two kinds of accuracy for this function are alternatives. To correct deviations in the oscillator frequency of the crystal, the oscillation adjustment circuit is configured to allow correction of a time count gain or loss (up to ±1.5ppm or ±0.5ppm at 25°C) from the CPU. The maximum range is approximately ±189ppm (or ±63ppm) in increments of approximately 3ppm (or 1ppm). Such oscillation frequency adjustment in each system has the following advantages: * Allows timekeeping with much higher precision than conventional RTCs while using a quartz crystal unit with a wide range of precision variations. * Corrects seasonal frequency deviations through seasonal oscillation adjustment. * Allows timekeeping with higher precision particularly with a temperature sensing function out of RTC, through oscillation adjustment in tune with temperature fluctuations. • Power-on Reset, Oscillation Halt Sensing Function and Supply Voltage Monitoring Function The R2051 has 3 power supply pins (VCC, VSB, VDD), among them, VCC pin and VDD pin have monitoring function of supply voltage. VCC power supply monitoring circuit makes VDCC pin “L” when VCC power supply pin becomes equal or lower than –VDET1. At the power-on of VCC, this circuit makes VDCC pin turn off, or “H” after the delay time, tDELAY from when the VCC power supply pin becomes equal or more than +VDET1. R2051Txx does not have VDCC output pin. The R2051 incorporates an oscillation halt sensing circuit equipped with internal registers configured to record any past oscillation halt, the oscillation halt sensing circuit, VDD monitoring flag, and power-on reset flag are useful for judging the validity of time data. Power on reset function reset the control resisters when the system is powered on from 0V. At the same time, the fact is memorized to the resister as a flag, thereby identifying whether they are powered on from 0V or battery backed-up. The R2051 also incorporates a supply voltage monitoring circuit equipped with internal registers configured to record any drop in supply voltage below a certain threshold value. Supply voltage monitoring threshold settings can be selected between 2.1V and 1.35V through internal register settings. The sampling rate is normally 1s. The oscillation halt sensing circuit is configured to confirm the established invalidation of time data in contrast to the supply voltage monitoring circuit intended to confirm the potential invalidation of time data. Further, the supply voltage monitoring circuit can be applied to battery supply voltage monitoring. • Periodic Interrupt Function The R2051 incorporates the periodic interrupt circuit configured to generate periodic interrupt signals aside from interrupt signals generated by the periodic interrupt circuit for output from the INTR pin. Periodic interrupt signals have five selectable frequency settings of 2 Hz (once per 0.5 seconds), 1 Hz (once per 1 second), 1/60 Hz (once per 1 minute), 1/3600 Hz (once per 1 hour), and monthly (the first day of every month). Further, periodic interrupt signals also have two selectable waveforms, a normal pulse form (with a frequency of 2 Hz or 1 Hz) and special 15 R2051 Series form adapted to interruption from the CPU in the level mode (with second, minute, hour, and month interrupts). The condition of periodic interrupt signals can be monitored with using a polling function. R2051Txx has the periodic interrupt registers, but does not have INTR output pin. • 32kHz Clock Output The R2051 incorporates a 32-kHz clock circuit configured to generate clock pulses with the oscillation frequency of a 32.768kHz quartz crystal unit for output from the CLKOUT pin (CMOS push-pull output). The 32-kHz clock output is always enabled and the “H” level of the CLKOUT pin is same as VCC power supply. 16 R2051 Series Address Mapping 0 Address A3A2A1A0 0 0 0 0 Register Name Second Counter 1 2 0 0 0 1 0 0 1 0 Minute Counter Hour Counter 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 7 0 1 1 0 0 1 1 1 8 1 0 0 0 9 1 0 0 1 A 1 0 1 0 B 1 0 1 1 C 1 1 0 0 Day-of-week Counter Day-of-month Counter Month Counter and Century Bit Year Counter Oscillation Adjustment Register *3) Alarm_W (Minute Register) Alarm_W (Hour Register) Alarm_W (Day-of-week Register) Alarm_D (Minute Register) Alarm_D (Hour Register) D E 1 1 0 1 1 1 1 0 F 1 1 1 1 Control Register 1 *3) Control Register 2 *3) D7 *2) - D6 S40 D5 S20 D4 S10 D3 S8 Data D2 D1 S4 S2 M40 - M10 H10 M8 H8 M4 H4 M2 H2 M1 H1 - - M20 H20 P/ A - - - W4 W2 W1 - - D20 D10 D8 D4 D2 D1 - - MO10 MO8 MO4 MO2 MO1 Y40 F6 Y20 F5 Y10 F4 Y8 F3 Y4 F2 Y2 F1 Y1 F0 WM40 WM20 WM10 WM8 WM4 WM2 WM1 19 /20 Y80 DEV *4) - WW6 - DM40 - - WALE VDSL DALE VDET WH20 WP/ A WW5 WH10 WW4 WH8 WH4 WH2 D0 S1 WH1 WW3 WW2 WW1 WW0 DM20 DM10 DM8 DM4 DM2 DM1 DH20 DP/ A 12 /24 DH10 DH8 DH4 DH2 DH1 CT2 CT1 CT0 XST SCRA TEST TCH2 PON SCRA *5) TCH1 CTFG WAFG DAFG Notes: * 1) All the data listed above accept both reading and writing. * 2) The data marked with "-" is invalid for writing and reset to 0 for reading. * 3) When the PON bit is set to 1 in Control Register 2, all the bits are reset to 0 in Oscillation Adjustment Register, Control Register 1 and Control Register 2 excluding the XST bit. * 4) When DEV=0, the oscillation adjustment circuit is configured to allow correction of a time count gain or loss up to ±1.5ppm. When DEV=1, the oscillation adjustment circuit is configured to allow correction of a time count gain or loss up to or ±0.5ppm. * 5) PON is a power-on-reset flag. 17 R2051 Series Register Settings • Control Register 1 (Address Eh) D7 WALE *) D6 DALE D4 D3 D2 D1 D0 SCRA TEST CT2 CT1 CT0 (For Writing) TCH2 SCRA TEST CT2 CT1 CT0 (For Reading) WALE DALE 12 /24 TCH2 0 0 0 0 0 0 0 0 Default Settings *) Default settings: Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. (1) WALE, DALE WALE,DALE 0 1 (2) 12 /24 D5 12 /24 Alarm_W Enable Bit, Alarm_D Enable Bit Description Disabling the alarm interrupt circuit (under the control of the settings of the Alarm_W registers and the Alarm_D registers). Enabling the alarm interrupt circuit (under the control of the settings of the Alarm_W registers and the Alarm_D registers) 12 /24-hour Mode Selection Bit 12 /24 Description 0 Selecting the 12-hour mode with a.m. and p.m. indications. 1 Selecting the 24-hour mode Setting the 12 /24 bit to 0 and 1 specifies the 12-hour mode and the 24-hour mode, respectively. 24-hour mode 12-hour mode 24-hour mode 00 12 (AM12) 12 01 01 (AM 1) 13 02 02 (AM 2) 14 03 03 (AM 3) 15 04 04 (AM 4) 16 05 05 (AM 5) 17 06 06 (AM 6) 18 07 07 (AM 7) 19 08 08 (AM 8) 20 09 09 (AM 9) 21 10 10 (AM10) 22 11 11 (AM11) 23 Setting the 12 /24 bit should precede writing time data (3) SCRATCH2 Scratch Bit 2 (Default) Test Bit TEST Description 0 Normal operation mode. 1 Test mode. The TEST bit is used only for testing in the factory and should normally be set to 0. 18 (Default) 12-hour mode 32 (PM12) 21 (PM 1) 22 (PM 2) 23 (PM 3) 24 (PM 4) 25 (PM 5) 26 (PM 6) 27 (PM 7) 28 (PM 8) 29 (PM 9) 30 (PM10) 31 (PM11) SCRATCH2 Description 0 1 The SCRATCH2 bit is intended for scratching and accepts the reading and writing of 0 and 1. The SCRATCH2 bit will be set to 0 when the PON bit is set to 1 in the Control Register 1. (4) TEST (Default) (Default) R2051 Series (5) CT2, CT1, and CT0 CT2 CT1 Periodic Interrupt Selection Bits CT0 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 Wave form mode Pulse Mode *1) Pulse Mode *1) Level Mode *2) Level Mode *2) Level Mode *2) Level Mode *2) Description Interrupt Cycle and Falling Timing OFF(H) Fixed at “L” 2Hz (Duty50%) (Default) 1Hz (Duty50%) Once per 1 second (Synchronized with second counter increment) Once per 1 minute (at 00 seconds of every minute) Once per hour (at 00 minutes and 00 seconds of every hour) Once per month (at 00 hours, 00 minutes, and 00 seconds of first day of every month) * 1) Pulse Mode: 2-Hz and 1-Hz clock pulses are output in synchronization with the increment of the second counter as illustrated in the timing chart below. CTFG Bit INTR Pin Approx. 92µs (Increment of second counter) Rewriting of the second counter In the pulse mode, the increment of the second counter is delayed by approximately 92 µs from the falling edge of clock pulses. Consequently, time readings immediately after the falling edge of clock pulses may appear to lag behind the time counts of the real-time clocks by approximately 1 second. Rewriting the second counter will reset the other time counters of less than 1 second, driving the INTR pin low. * 2) Level Mode: Periodic interrupt signals are output with selectable interrupt cycle settings of 1 second, 1 minute, 1 hour, and 1 month. The increment of the second counter is synchronized with the falling edge of periodic interrupt signals. For example, periodic interrupt signals with an interrupt cycle setting of 1 second are output in synchronization with the increment of the second counter as illustrated in the timing chart below. CTFG Bit INTR Pin Setting CTFG bit to 0 (Increment of second counter) (Increment of second counter) Setting CTFG bit to 0 (Increment of second counter) 19 R2051 Series *1), *2) When the oscillation adjustment circuit is used, the interrupt cycle will fluctuate once per 20sec. or 60sec. as follows: Pulse Mode: The “L” period of output pulses will increment or decrement by a maximum of ±3.784 ms. For example, 1-Hz clock pulses will have a duty cycle of 50 ±0.3784%. Level Mode: A periodic interrupt cycle of 1 second will increment or decrement by a maximum of ±3.784 ms. R2051Txx does not have INTR output pin • Control Register 2 (Address Fh) *) D7 VDSL D6 VDET VDSL VDET 0 0 Default settings: (1) VDSL D5 XST D4 PON D3 D2 D1 D0 SCRA CTFG WAFG DAFG (For Writing) TCH1 PON SCRA CTFG WAFG DAFG (For Reading) XST TCH1 Indefinite 1 0 0 0 0 Default Settings *) Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. VDD Supply Voltage Monitoring Threshold Selection Bit VDSL 0 Description Selecting the VDD supply voltage monitoring threshold setting of 2.1v. 1 Selecting the VDD supply voltage monitoring threshold setting of 1.35v. The VDSL bit is intended to select the VDD supply voltage monitoring threshold settings. (2) VDET (Default) Supply Voltage Monitoring Result Indication Bit VDET 0 Description Indicating supply voltage above the supply voltage monitoring (Default) threshold settings. 1 Indicating supply voltage below the supply voltage monitoring threshold settings. Once the VDET bit is set to 1, the supply voltage monitoring circuit will be disabled while the VDET bit will hold the setting of 1. The VDET bit accepts only the writing of 0, which restarts the supply voltage monitoring circuit. Conversely, setting the VDET bit to 1 causes no event. (3) XST Oscillation Halt Sensing Monitor Bit Description XST 0 Sensing a halt of oscillation 1 Sensing a normal condition of oscillation The XST accepts the reading and writing of 0 and 1. The XST bit will be set to 0 when the oscillation halt sensing. The XST bit will hold 0 even after the restart of oscillation. (4) PON Power-on-reset Flag Bit PON Description 0 Normal condition 1 Detecting VDD power-on -reset The PON bit is for sensing power-on reset condition. * The PON bit will be set to 1 when VDD power-on from 0 volts. after power-on. 20 (Default) The PON bit will hold the setting of 1 even R2051 Series * When the PON bit is set to 1, all bits will be reset to 0, in the Oscillation Adjustment Register, Control Register 1, and Control Register 2, except XST and PON. As a result, INTR pin stops outputting. * The PON bit accepts only the writing of 0. Conversely, setting the PON bit to 1 causes no event. (5) SCRATCH1 Scratch Bit 1 SCRATCH1 Description 0 (Default) 1 The SCRATCH1 bit is intended for scratching and accepts the reading and writing of 0 and 1. The SCRATCH1 bit will be set to 0 when the PON bit is set to 1 in the Control Register 2. (6) CTFG Periodic Interrupt Flag Bit CTFG Description 0 Periodic interrupt output = “H” (Default) 1 Periodic interrupt output = “L” The CTFG bit is set to 1 when the periodic interrupt signals are output from the INTR pin (“L”). The CTFG bit accepts only the writing of 0 in the level mode, which disables (“H”) the INTR pin until it is enabled (“L”) again in the next interrupt cycle. Conversely, setting the CTFG bit to 1 causes no event. R2051Txx has CTFG bit, but does not have INTR output pin (7) WAFG,DAFG Alarm_W Flag Bit and Alarm_D Flag Bit WAFG,DAFG Description 0 Indicating a mismatch between current time and preset alarm time (Default) 1 Indicating a match between current time and preset alarm time The WAFG and DAFG bits are valid only when the WALE and DALE have the setting of 1, which is caused approximately 61µs after any match between current time and preset alarm time specified by the Alarm_W registers and the Alarm_D registers. The WAFG (DAFG) bit accepts only the writing of 0. INTR pin outputs off (“H”) when this bit is set to 0. And INTR pin outputs “L” again at the next preset alarm time. Conversely, setting the WAFG and DAFG bits to 1 causes no event. The WAFG and DAFG bits will have the reading of 0 when the alarm interrupt circuit is disabled with the WALE and DALE bits set to 0. The settings of the WAFG and DAFG bits are synchronized with the output of the INTR pin as shown in the timing chart below. R2051Txx has WAFG, DAFG bits. But does not have INTR output pin. Approx. 61µs Approx. 61µs WAFG(DAFG) Bit INTR Pin Writing of 0 to WAFG(DAFG) bit Writing of 0 to WAFG(DAFG) bit (Match between (Match between (Match between current time and current time and current time and preset alarm time) preset alarm time) preset alarm time) 21 R2051 Series • Time Counter (Address 0-2h) Second Counter (Address 0h) D7 D6 D5 S40 S20 0 S40 S20 0 Indefi Indefi nite nite D4 S10 S10 Indefi nite D3 S8 S8 Indefi nite D2 S4 S4 Indefi nite D1 S2 S2 Indefi nite D0 S1 S1 Indefi nite (For Writing) (For Reading) Default Settings *) Minute Counter (Address 1h) D7 D6 D5 M40 M20 0 M40 M20 0 Indefi Indefi nite nite D4 M10 M10 Indefi nite D3 M8 M8 Indefi nite D2 M4 M4 Indefi nite D1 M2 M2 Indefi nite D0 M1 M1 Indefi nite (For Writing) (For Reading) Default Settings *) Hour Counter (Address 2h) D7 D6 D5 D4 D3 D2 D1 D0 H10 H8 H4 H2 H1 (For Writing) P/ A or H20 H10 H8 H4 H2 H1 (For Reading) 0 0 P/ A or H20 0 0 Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. * Time digit display (BCD format) as follows: The second digits range from 00 to 59 and are carried to the minute digit in transition from 59 to 00. The minute digits range from 00 to 59 and are carried to the hour digits in transition from 59 to 00. The hour digits range as shown in "P18 • Control Register 1 (ADDRESS Eh) (2) 12 /24: 12 /24-hour Mode Selection Bit" and are carried to the day-of-month and day-of-week digits in transition from PM11 to AM12 or from 23 to 00. * Any writing to the second counter resets divider units of less than 1 second. * Any carry from lower digits with the writing of non-existent time may cause the time counters to malfunction. Therefore, such incorrect writing should be replaced with the writing of existent time data. • Day-of-week Counter (Address 3h) D7 0 0 *) D6 0 0 Default settings: D5 0 0 D4 0 0 D3 0 0 D2 D1 D0 W4 W2 W1 (For Writing) W4 W2 W1 (For Reading) Indefi Indefi Indefi Default Settings *) nite nite nite Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. * The day-of-week counter is incremented by 1 when the day-of-week digits are carried to the day-of-month digits. * Day-of-week display (incremented in septimal notation): (W4, W2, W1) = (0, 0, 0) → (0, 0, 1)→…→(1, 1, 0) → (0, 0, 0) 22 R2051 Series * Correspondences between days of the week and the day-of-week digits are user-definable (e.g. Sunday = 0, 0, 0) * The writing of (1, 1, 1) to (W4, W2, W1) is prohibited except when days of the week are unused. • Calendar Counter (Address 4-6h) Day-of-month Counter (Address 4h) D7 D6 D5 D4 D20 D10 0 0 D20 D10 0 0 Indefi Indefi nite nite D3 D8 D8 Indefi nite D2 D4 D4 Indefi nite D1 D2 D2 Indefi nite D0 D1 D1 Indefi nite (For Writing) (For Reading) Default Settings *) Month Counter + Century Bit (Address 5h) D7 D6 D5 D4 MO10 19 /20 0 0 MO10 19 /20 Indefi 0 0 Indefi nite nite D3 MO8 MO8 Indefi nite D2 MO4 MO4 Indefi nite D1 MO2 MO2 Indefi nite D0 MO1 MO1 Indefi nite (For Writing) (For Reading) Default Settings *) Year Counter (Address 6h) D7 D6 D5 D4 D3 D2 D1 D0 Y80 Y40 Y20 Y10 Y8 Y4 Y2 Y1 (For Writing) Y80 Y40 Y20 Y10 Y8 Y4 Y2 Y1 (For Reading) Indefi Indefi Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. * The calendar counters are configured to display the calendar digits in BCD format by using the automatic calendar function as follows: The day-of-month digits (D20 to D1) range from 1 to 31 for January, March, May, July, August, October, and December; from 1 to 30 for April, June, September, and November; from 1 to 29 for February in leap years; from 1 to 28 for February in ordinary years. The day-of-month digits are carried to the month digits in reversion from the last day of the month to 1. The month digits (MO10 to MO1) range from 1 to 12 and are carried to the year digits in reversion from 12 to 1. The year digits (Y80 to Y1) range from 00 to 99 (00, 04, 08, …, 92, and 96 in leap years) and are carried to the 19 /20 digits in reversion from 99 to 00. The 19 /20 digits cycle between 0 and 1 in reversion from 99 to 00 in the year digits. * Any carry from lower digits with the writing of non-existent calendar data may cause the calendar counters to malfunction. Therefore, such incorrect writing should be replaced with the writing of existent calendar data. 23 R2051 Series • Oscillation Adjustment Register (Address 7h) *) D7 D6 DEV F6 DEV F6 0 0 Default settings: D5 D4 D3 D2 D1 D0 F5 F4 F3 F2 F1 F0 (For Writing) F5 F4 F3 F2 F1 F0 (For Reading) 0 0 0 0 0 0 Default Settings *) Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. DEV bit When DEV is set to 0, the Oscillation Adjustment Circuit operates 00, 20, 40 seconds. When DEV is set to 1, the Oscillation Adjustment Circuit operates 00 seconds. F6 to F0 bits The Oscillation Adjustment Circuit is configured to change time counts of 1 second on the basis of the settings of the Oscillation Adjustment Register at the timing set by DEV. * The Oscillation Adjustment Circuit will not operate with the same timing (00, 20, or 40 seconds) as the timing of writing to the Oscillation Adjustment Register. * The F6 bit setting of 0 causes an increment of time counts by ((F5, F4, F3, F2, F1, F0) - 1) x 2. The F6 bit setting of 1 causes a decrement of time counts by (( F5,F4,F3,F2,F1,F0 ) + 1) x 2. The settings of "*, 0, 0, 0, 0, 0, *" ("*" representing either "0" or "1") in the F6, F5, F4, F3, F2, F1, and F0 bits cause neither an increment nor decrement of time counts. Example: If (DEV, F6, F5, F4, F3, F2, F1, F0) is set to (0, 0, 0, 0, 0, 1, 1, 1), when the second digits read 00, 20, or 40, an increment of the current time counts of 32768 + (7 - 1) x 2 to 32780 (a current time count loss). If (DEV, F6, F5, F4, F3, F2, F1, F0) is set to (0, 0, 0, 0, 0, 0, 0, 1), when the second digits read 00, 20, 40, neither an increment nor a decrement of the current time counts of 32768. If (DEV, F6, F5, F4, F3, F2, F1, F0) is set to (1, 1, 1, 1, 1, 1, 1, 0), when the second digits read 00, a decrement of the current time counts of 32768 + (- 2) x 2 to 32764 (a current time count gain). An increase of two clock pulses once per 20 seconds causes a time count loss of approximately 3 ppm (2 / (32768 x 20) = 3.051 ppm). Conversely, a decrease of two clock pulses once per 20 seconds causes a time count gain of 3 ppm. Consequently, when DEV is set to “0”, deviations in time counts can be corrected with a precision of ±1.5 ppm. In the same way, when DEV is set to “1”, deviations in time counts can be corrected with a precision of ±0.5 ppm. Note that the oscillation adjustment circuit is configured to correct deviations in time counts and not the oscillation frequency of the 32.768-kHz clock pulses. For further details, see "P38 Configuration of Oscillation Circuit and Correction of Time Count Deviations • Oscillation Adjustment Circuit". 24 R2051 Series Alarm_W Registers (Address 8-Ah) Alarm_W Minute Register (Address 8h) D7 D6 D5 D4 WM40 WM20 WM10 0 WM40 WM20 WM10 0 Indefi Indefi Indefi nite nite nite Alarm_W Hour Register (Address 9h) D7 D6 D5 D4 WH20 WH10 WP/ A WH10 0 0 WH20 WP/ A 0 0 Indefi Indefi nite nite D3 WM8 WM8 Indefi nite D2 WM4 WM4 Indefi nite D1 WM2 WM2 Indefi nite D0 WM1 WM1 Indefi nite D3 WH8 D2 WH4 D1 WH2 D0 WH1 (For Writing) WH8 WH4 WH2 WH1 (For Reading) Indefi nite Indefi nite Indefi nite Indefi nite Default Settings *) (For Writing) (For Reading) Default Settings *) Alarm_W Day-of-week Register (Address Ah) D7 D6 D5 D4 D3 D2 D1 D0 WW6 WW5 WW4 WW3 WW2 WW1 WW0 (For Writing) 0 WW6 WW5 WW4 WW3 WW2 WW1 WW0 (For Reading) 0 Indefi Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. * The D5 bit of the Alarm_W Hour Register represents WP/ A when the 12-hour mode is selected (0 for a.m. and 1 for p.m.) and WH20 when the 24-hour mode is selected (tens in the hour digits). * The Alarm_W Registers should not have any non-existent alarm time settings. (Note that any mismatch between current time and preset alarm time specified by the Alarm_W registers may disable the alarm interrupt circuit.) * When the 12-hour mode is selected, the hour digits read 12 and 32 for 0 a.m. and 0 p.m., respectively. (See "P18 •Control Register 1 (ADDRESS Eh) (2) 12 /24: 12 /24-hour Mode Selection Bit") * WW0 to WW6 correspond to W4, W2, and W1 of the day-of-week counter with settings ranging from (0, 0, 0) to (1, 1, 0). * WW0 to WW6 with respective settings of 0 disable the outputs of the Alarm_W Registers. 25 R2051 Series Example of Alarm Time Setting Alarm Day-of-week Preset alarm Sun. Mon. Tue. Wed. Th. time WW 0 1 WW 1 1 WW 2 1 WW 3 1 WW 4 1 Fri. Sat. WW 5 1 WW 6 1 12-hour mode 1 1 1 1 0 h 0 m h r m in r. . in . . 1 0 h r . 24-hour mode 1 1 1 h 0 mi r. m n. in . 00:00 a.m. on all 1 2 0 0 0 0 0 days 01:30 a.m. on all 1 1 1 1 1 1 1 0 1 3 0 0 1 3 days 11:59 a.m. on all 1 1 1 1 1 1 1 1 1 5 9 1 1 5 days 00:00 p.m. on Mon. 0 1 1 1 1 1 0 3 2 0 0 1 2 0 to Fri. 01:30 p.m. on Sun. 1 0 0 0 0 0 0 2 1 3 0 1 3 3 11:59 p.m. 0 1 0 1 0 1 0 3 1 5 9 2 3 5 on Mon. ,Wed., and Fri. Note that the correspondence between WW0 to WW6 and the days of the week shown in the above table is only an example and not mandatory. • 0 0 9 0 0 9 Alarm_D Register (Address B-Ch) Alarm_D Minute Register (Address Bh) D7 D6 D5 D4 DM40 DM20 DM10 0 DM40 DM20 DM10 0 Indefi Indefi Indefi nite nite nite D3 DM8 DM8 Indefi nite D2 DM4 DM4 Indefi nite D1 DM2 DM2 Indefi nite D0 DM1 DM1 Indefi nite (For Writing) (For Reading) Default Settings *) Alarm_D Hour Register (Address Ch) D7 D6 D5 D4 D3 D2 D1 D0 DH20 DH10 DH8 DH4 DH2 DH1 (For Writing) A DP/ DH10 DH8 DH4 DH2 DH1 (For Reading) 0 0 DH20 DP/ A 0 0 Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. * The D5 bit represents DP/ A when the 12-hour mode is selected (0 for a.m. and 1 for p.m.) and DH20 when the 24-hour mode is selected (tens in the hour digits). * The Alarm_D registers should not have any non-existent alarm time settings. (Note that any mismatch between current time and preset alarm time specified by the Alarm_D registers may disable the alarm interrupt circuit.) * When the 12-hour mode is selected, the hour digits read 12 and 32 for 0a.m. and 0p.m., respectively. (See "P18 •Control Register 1 (Address Eh) (2) 12 /24: 12 /24-hour Mode Selection Bit") 26 R2051 Series Interfacing with the CPU The R2051 employs the I2C-Bus system to be connected to the CPU via 2-wires. I C-Bus are described in the following sections. Connection and system of 2 • Connection of I2C-Bus 2-wires, SCL and SDA pins that are connected to I2C-Bus are used for transmit clock pulses and data respectively. All ICs that are connected to these lines are designed that will not be clamped when a voltage beyond supply voltage is applied to input or output pins. Open drain pins are used for output. This construction allows communication of signals between ICs with different supply voltages by adding a pull-up resistor to each signal line as shown in the figure below. Each IC is designed not to affect SCL and SDA signal lines when power to each of these is turned off separately. VDD1 * For data interface, the following conditions must be met: VCC4≥VCC1 VCC4≥VCC2 VCC4≥VCC3 VDD2 VDD3 VDD4 Rp Rp * SCL SDA MicroController R2051 When the master is one, the micro-controller is ready for driving SCL to “H” and Rp of SCL may not be required. Other Peripheral Device Cautions on determining Rp resistance, (1) Dropping voltage at Rp due to sum of input current or output current at off conditions on each IC pin connected to the I2C-Bus shall be adequately small. (2) Rising time of each signal be kept short even when all capacity of the bus is driven. (3) Current consumed in I2C-Bus is small compared to the consumption current permitted for the entire system. When all ICs connected to I2C-Bus are CMOS type, condition (1) may usually be ignored since input current and off-state output current is extremely small for the many CMOS type ICs. Thus the maximum resistance of Rp may be determined based on (2), while the minimum on (3) in most cases. In actual cases a resistor may be place between the bus and input/output pins of each IC to improve noise margins in which case the Rp minimum value may be determined by the resistance. Consumption current in the bus to review (3) above may be expressed by the formula below: Bus consumption current ≈ (Sum of input current and off state output current of all devices in standby mode ) × Bus standby duration Bus stand-by duration + the Bus operation duration + Supply voltage × Bus operation duration × 2 Rp resistance × 2 × (Bus stand-by duration + bus operation duration) + Supply voltage × Bus capacity × Charging/Discharging times per unit time Operation of “× 2” in the second member denominator in the above formula is derived from assumption that “L” 27 R2051 Series duration of SDA and SCL pins are the half of bus operation duration. “× 2” in the numerator of the same member is because there are two pins of SDA and SCL. The third member, (charging/discharging times per unit time) means number of transition from “H” to “L” of the signal line. Calculation example is shown below: Pull-up resistor (Rp) = 10kΩ, Bus capacity = 50pF(both for SCL, SDA), VCC=3v, In a system with sum of input current and off-state output current of each pin = 0.1µA, I2C-Bus is used for 10ms every second while the rest of 990ms in the stand-by mode, In this mode, number of transitions of the SCL pin from “H” to “L” state is 100 while SDA 50, every second. Bus consumption current ≈ + 0.1µA×990msec 990msec + 10msec 3V × 10msec × 2 10KΩ × 2 × (990msec + 10msec) + 3V × 50pF × (100 + 50) ≈ 0.099µA + 3.0µA + 0.0225µA ≈ 3.12µA Generally, the second member of the above formula is larger enough than the first and the third members bus consumption current may be determined by the second member is many cases. 28 R2051 Series • Transmission System of I2C-Bus (1) Start Condition and Stop Condition In I2C-Bus, SDA must be kept at a certain state while SCL is at the “H” state during data transmission as shown below. SCL SDA tHD;DAT tSU;DAT The SCL and SDA pins are at the “H” level when no data transmission is made. Changing the SDA from “H” to “L” when the SCL and the SDA are “H” activates the Start Condition and access is started. Changing the SDA from “L” to “H” when the SCL is “H” activates Stop Condition and accessing stopped. Generation of Start and Stop Conditions are always made by the master (see the figure below). Start Condition Stop Condition SCL SDA tHD;STA • tSU;STO (2) Data transmission and its acknowledge After Start condition is entered, data is transmitted by 1byte (8bits). Any bytes of data may be serially transmitted. The receiving side will send an acknowledge signal to the transmission side each time 8bit data is transmitted. The acknowledge signal is sent immediately after falling to “L” of SCL 8bit clock pulses of data is transmitted, by releasing the SDA by the transmission side that has asserted the bus at that time and by turning SDA to “L” by receiving side. When transmission of 1byte data next to preceding 1byte of data is received the receiving side releases the SDA pin at falling edge of the SCL 9bit of clock pulses or when the receiving side switches to the transmission side it starts data transmission. When the master is receiving side, it generates no acknowledge signal after last 1byte of data from the slave to tell the transmitter that data transmission has completed. The slave side (transmission side) continues to release the SDA pin so that the master will be able to generate Stop Condition, after falling edge of the SCL 9bit of clock pulses. 29 R2051 Series SCL from the master 1 2 8 9 SDA from the transmission side SDA from the receiving side Start Condition Acknowledge signal (3) Data Transmission Format in I2C-Bus I2C-Bus has no chip enable signal line. In place of it, each device has a 7bit Slave Address allocated. The first 1byte is allocated to this 7bit address and to the command (R/W) for which data transmission direction is designated by the data transmission thereafter. 7bit address is sequentially transmitted from the MSB and 2 and after bytes are read, when 8bit is “H” and when write “L”. The Slave Address of the R2051 is specified at (0110010). At the end of data transmission / receiving, Stop Condition is generated to complete transmission. However, if start condition is generated without generating Stop Condition, Repeated Start Condition is met and transmission / receiving data may be continue by setting the Slave Address again. Use this procedure when the transmission direction needs to be change during one transmission. Data is written to the slave from the master S Slave Address (0110010) When data is read from the slave immediately after 7bit addressing from the master S S Slave Address 1 A Data A P Slave Address Data 0 A R/W=0(Write) Data A Data A /A P Inform read has been completed by not generate an acknowledge signal to the slave side. R/W=1(Read) (0110010) A Data A R/W=0(Write) (0110010) When the transmission direction is to be changed during transmission. Data 0 A A Sr Salve Address (0110010) Data 1 R/W=1(Read) /A P Inform read has been completed by not generate an acknowledge signal to the slave side. Master to slave S 30 Start Condition P Slave to master A Stop Condition Sr A /A Acknowledge Signal Repeated Start Condition R2051 Series (4) Data Transmission Write Format in the R2051 Although the I2C-Bus standard defines a transmission format for the slave allocated for each IC, transmission method of address information in IC is not defined. The R2051 transmits data the internal address pointer (4bit) and the Transmission Format Register (4bit) at the 1byte next to one which transmitted a Slave Address and a write command. For write operation only one transmission format is available and (0000) is set to the Transmission Format Register. The 3byte transmits data to the address specified by the internal address pointer written to the 2byte. Internal address pointer setting are automatically incremented for 4byte and after. Note that when the internal address pointer is Fh, it will change to 0h on transmitting the next byte. Example of data writing (When writing to internal address Eh to Fh) R/W=0(Write) Data S 0 1 1 0 0 1 0 0 A 1 1 1 0 0 0 0 0 A Slave Address ←(0110010) Address Transmission Pointer Format ←Eh Register ← Writing of data to the internal address Eh A Data A P Writing of data to the internal address Fh 0h Master to slave S A Start Condition A /A Slave to master P Stop Condition Acknowledge signal 31 R2051 Series (5) Data transmission read format of the R2051 The R2051 allows the following three read out method of data an internal register. The first method to reading data from the internal register is to specify an internal address by setting the internal address pointer and the transmission format register described P31 (4), generate the Repeated Start Condition (See P30 (3)) to change the data transmission direction to perform reading. The internal address pointer is set to Fh when the Stop Condition is met. Therefore, this method of reading allows no insertion of Stop Condition before the Repeated Start Condition. Set 0h to the Transmission Format Register when this method used. Example 1 of Data Read (when data is read from 2h to 4h) Repeated Start Condition R/W=0(Write) R/W=1(Read) S 0 1 1 0 0 1 0 0 A 0 0 1 0 0 0 0 0 A Sr 0 1 1 0 0 1 0 1 A Address Transmission Pointer←2h Format Slave Address ← (0110010) Slave Address ← (0110010) Register←0h Data Reading of data from the internal address 2h Data A Reading of data from the internal address 3h Master to slave S A 32 Start Condition A /A Acknowledge signal Data A /A P Reading of data from the internal address 4h Slave to master Sr Repeated Start Condition P Stop Condition R2051 Series The second method to reading data from the internal register is to start reading immediately after writing to the Internal Address Pointer and the Transmission Format Register. Although this method is not based on I2C-Bus standard in a strict sense it still effective to shorten read time to ease load to the master. Set 4h to the transmission format register when this method used. Example 2 of data read (when data is read from internal addresses Eh to 1h) R/W=0(Write) Data S 0 1 1 0 0 1 0 0 A 1 1 1 0 0 1 0 0 A Address Transmission Pointer Format Register←4h ←Eh Slave Address ← (0110010) Data Reading of data from the internal address Fh Reading of data from the internal address 0h Master to slave S A Start Condition A /A Reading of data from the internal address Eh Data A A Data A /A P Reading of data from the internal address 1h Slave to Master P Stop Condition Acknowledge Signal The third method to reading data from the internal register is to start reading immediately after writing to the Slave Address and R/W bit. Since the Internal Address Pointer is set to Fh by default as described in the first method, this method is only effective when reading is started from the Internal Address Fh. 33 R2051 Series Example 3 of data read (when data is read from internal addresses Fh to 3h) R/W=1(Read) Data S 0 1 1 0 0 1 0 1 A Slave Address ← (0110010) Reading of data from the Internal Address Fh Data Reading of data from the Internal Address 1h Reading of data from the Internal Address 2h A • Start Condition A /A A Reading of data from the Internal Address 0h Data A Master to slave S Data A Data A /A P Reading of data from the Internal Address 3h Slave to master P Stop Condition Acknowledge Signal Data Transmission under Special Condition The R2051 holds the clock tentatively for duration from Start Condition to avoid invalid read or write clock on carrying clock. When clock carried during this period, which will be adjusted within approx. 61µs from Stop Condition. To prevent invalid read or write, clock and calendar data shall be made during one transmission operation (from Start Condition to Stop Condition). When 0.5 to 1.0 second elapses after Start Condition, any access to the R2051 is automatically released to release tentative hold of the clock, and access from the CPU is forced to be terminated (The same action as made Stop Condition is received: automatic resume function from I2C-Bus interface). Therefore, one access must be complete within 0.5 seconds. The automatic resume function prevents delay in clock even if SCL is stopped from sudden failure of the system during clock read operation. Also a second Start Condition after the first Start Condition and before the Stop Condition is regarded “Repeated Start Condition”. Therefore, when 0.5 to 1.0 seconds passed after the first Start Condition, an access to the R2051 is automatically released. If access is tried after automatic resume function is activated, no acknowledge signal will be output for writing while FFh will be output for reading. The user shall always be able to access the real-time clock as long as three conditions are met. No Stop Condition shall be generated until clock and calendar data read/write is started and completed. One cycle read/write operation shall be complete within 0.5 seconds. Do not make Start Condition within 61µs from Stop Condition. When clock is carried during the access, which will be adjusted within approx. 61µs from Stop Condition. Bad example of reading from seconds to hours (invalid read) (Start Condition) → (Read of seconds) → (Read of minutes) → (Stop Condition) → (Start Condition) → (Read of hour) → (Stop Condition) Assuming read was started at 05:59:59 P.M. and while reading seconds and minutes the time advanced to 06:00:00 P.M. At this time second digit is hold so read the read as 05:59:59. Then the R2051 confirms (Stop Condition) and carries second digit being hold and the time change to 06:00:00 P.M. Then, when the hour digit is read, it changes to 6. The wrong results of 06:59:59 will be read. 34 R2051 Series Configuration of Oscillation Circuit and Correction of Time Count Deviations • Configuration of Oscillation Circuit OSCIN Oscillator CG Circuit 32kHz OSCOUT Typical externally-equipped element X’tal : 32.768kHz (R1=30kΩ typ) (CL=6pF to 8pF) Standard values of internal elements CG,CD 10pF typ CD A The oscillation circuit is driven at a constant voltage of approximately 1.2 volts relative to the level of the VSS pin input. As such, it is configured to generate an oscillating waveform with a peak-to-peak voltage on the order of 1.1 volts on the positive side of the VSS pin input. < Considerations in Handling quartz crystal unit > Generally, quartz crystal units have basic characteristics including an equivalent series resistance (R1) indicating the ease of their oscillation and a load capacitance (CL) indicating the degree of their center frequency. Particularly, quartz crystal units intended for use in the R2051 are recommended to have a typical R1 value of 30kΩ and a typical CL value of 6 to 8pF. To confirm these recommended values, contact the manufacturers of quartz crystal units intended for use in these particular models. < Considerations in Installing Components around the Oscillation Circuit > 1) Install the quartz crystal unit in the closest possible vicinity to the real-time clock ICs. 2) Avoid laying any signal lines or power lines in the vicinity of the oscillation circuit (particularly in the area marked "A" in the above figure). 3) Apply the highest possible insulation resistance between the OSCIN and OSCOUT pins and the printed circuit board. 4) Avoid using any long parallel lines to wire the OSCIN and OSCOUT pins. 5) Take extreme care not to cause condensation, which leads to various problems such as oscillation halt. < Other Relevant Considerations > 1) We cannot recommend connecting the external input of 32.768-kHz clock pulses to the OSCIN pin. 2) To maintain stable characteristics of the quartz crystal unit, avoid driving any other IC through 32.768-kHz clock pulses output from the OSCOUT pin. 35 R2051 Series • Measurement of Oscillation Frequency VCC OSCIN OSCOUT 32768Hz Frequency Counter CLKOUT VDD VSS * 1) The R2051 is configured to generate 32.768-kHz clock pulses for output from the CLKOUT pin. * 2) A frequency counter with 6 (more preferably 7) or more digits on the order of 1ppm is recommended for use in the measurement of the oscillation frequency of the oscillation circuit. • Adjustment of Oscillation frequency The oscillation frequency of the oscillation circuit can be adjusted by varying procedures depending on the usage of Model R2051 in the system into which they are to be built and on the allowable degree of time count errors. The flow chart below serves as a guide to selecting an optimum oscillation frequency adjustment procedure for the relevant system. Start Use 32-kHz clock output? YES NO Allowable time count precision on order of oscillation frequency variations of crystal oscillator (*1) plus NO frequency variations of RTC (*2)? (*3) YES YES Course (A) Course (B) Use 32-kHz clock output without regard to its frequency precision Course (C) NO YES Allowable time count precision on order of oscillation frequency variations of crystal oscillator (*1) plus NO frequency variations of RTC (*2)? (*3) Course (D) * 1) Generally, quartz crystal units for commercial use are classified in terms of their center frequency depending on their load capacitance (CL) and further divided into ranks on the order of ±10, ±20, and ±50ppm depending on the degree of their oscillation frequency variations. * 2) Basically, Model R2051 is configured to cause frequency variations on the order of ±5 to ±10ppm at 25°C. * 3) Time count precision as referred to in the above flow chart is applicable to normal temperature and actually affected by the temperature characteristics and other properties of quartz crystal units. 36 R2051 Series Course (A) When the time count precision of each RTC is not to be adjusted, the quartz crystal unit intended for use in that RTC may have any CL value requiring no presetting. The quartz crystal unit may be subject to frequency variations which are selectable within the allowable range of time count precision. Several quartz crystal units and RTCs should be used to find the center frequency of the quartz crystal units by the method described in "P36 • Measurement of Oscillation Frequency" and then calculate an appropriate oscillation adjustment value by the method described in "P38 • Oscillation Adjustment Circuit" for writing this value to the R2051. Course (B) When the time count precision of each RTC is to be adjusted within the oscillation frequency variations of the quartz crystal unit plus the frequency variations of the real-time clock ICs, it becomes necessary to correct deviations in the time count of each RTC by the method described in " P38 • Oscillation Adjustment Circuit". Such oscillation adjustment provides quartz crystal units with a wider range of allowable settings of their oscillation frequency variations and their CL values. The real-time clock IC and the quartz crystal unit intended for use in that real-time clock IC should be used to find the center frequency of the quartz crystal unit by the method described in " P36 • Measurement of Oscillation Frequency" and then confirm the center frequency thus found to fall within the range adjustable by the oscillation adjustment circuit before adjusting the oscillation frequency of the oscillation circuit. At normal temperature, the oscillation frequency of the oscillator circuit can be adjusted by up to approximately ±0.5ppm. Course (C) Course (C) together with Course (D) requires adjusting the time count precision of each RTC as well as the frequency of 32.768-kHz clock pulses output from the CLKOUT pin. Normally, the oscillation frequency of the quartz crystal unit intended for use in the RTCs should be adjusted by adjusting the oscillation stabilizing capacitors CG and CD connected to both ends of the quartz crystal unit. The R2051, which incorporate the CG and the CD, require adjusting the oscillation frequency of the quartz crystal unit through its CL value. Generally, the relationship between the CL value and the CG and CD values can be represented by the following equation: CL = (CG × CD)/(CG + CD) + CS where "CS" represents the floating capacity of the printed circuit board. The quartz crystal unit intended for use in the R2051 is recommended to have the CL value on the order of 6 to 8pF. Its oscillation frequency should be measured by the method described in " P36 • Measurement of Oscillation Frequency". Any quartz crystal unit found to have an excessively high or low oscillation frequency (causing a time count gain or loss, respectively) should be replaced with another one having a smaller and greater CL value, respectively until another one having an optimum CL value is selected. In this case, the bit settings disabling the oscillation adjustment circuit (see " P38 • Oscillation Adjustment Circuit ") should be written to the oscillation adjustment register. Incidentally, the high oscillation frequency of the quartz crystal unit can also be adjusted by adding an external oscillation stabilization capacitor CGout as illustrated in the diagram below. *1) The CGout should have a capacitance ranging from 0 to 15 pF. OSCIN Oscillator Circuit CG RD 32kHz OSCOUT CD CGout *1) 37 R2051 Series Course (D) It is necessary to select the quartz crystal unit in the same manner as in Course (C) as well as correct errors in the time count of each RTC in the same manner as in Course (B) by the method described in " P38 • Oscillation Adjustment Circuit ". • Oscillation Adjustment Circuit The oscillation adjustment circuit can be used to correct a time count gain or loss with high precision by varying the number of 1-second clock pulses once per 20 seconds or 60 seconds. When DEV bit in the Oscillation Adjustment Register is set to 0, R2051 varies number of 1-second clock pulses once per 20 seconds. When DEV bit is set to 1, R2051 varies number of 1-second clock pulses once per 60 seconds. The oscillation adjustment circuit can be disabled by writing the settings of "*, 0, 0, 0, 0, 0, *" ("*" representing "0" or "1") to the F6, F5, F4, F3, F2, F1, and F0 bits in the oscillation adjustment circuit. Conversely, when such oscillation adjustment is to be made, an appropriate oscillation adjustment value can be calculated by the equation below for writing to the oscillation adjustment circuit. (1) When Oscillation Frequency (* 1) Is Higher Than Target Frequency (* 2) (Causing Time Count Gain) When DEV=0: Oscillation adjustment value (*3) = (Oscillation frequency - Target Frequency + 0.1) Oscillation frequency × 3.051 × 10-6 ≈ (Oscillation Frequency – Target Frequency) × 10 + 1 When DEV=1: Oscillation adjustment value (*3) = (Oscillation frequency - Target Frequency + 0.0333) Oscillation frequency × 1.017 × 10-6 ≈ (Oscillation Frequency – Target Frequency) × 30 + 1 * 1) Oscillation frequency: Frequency of clock pulse output from the CLKOUT pin at normal temperature in the manner described in " P36 • Measurement of Oscillation Frequency". * 2) Target frequency: Desired frequency to be set. Generally, a 32.768-kHz quartz crystal unit has such temperature characteristics as to have the highest oscillation frequency at normal temperature. Consequently, the quartz crystal unit is recommended to have target frequency settings on the order of 32.768 to 32.76810 kHz (+3.05ppm relative to 32.768 kHz). Note that the target frequency differs depending on the environment or location where the equipment incorporating the RTC is expected to be operated. * 3) Oscillation adjustment value: Value that is to be finally written to the F0 to F6 bits in the Oscillation Adjustment Register and is represented in 7-bit coded decimal notation. (2) When Oscillation Frequency Is Equal To Target Frequency (Causing Time Count neither Gain nor Loss) Oscillation adjustment value = 0, +1, -64, or –63 (3) When Oscillation Frequency Is Lower Than Target Frequency (Causing Time Count Loss) When DEV=0: Oscillation adjustment value = (Oscillation frequency - Target Frequency) 38 R2051 Series Oscillation frequency × 3.051 × 10-6 ≈ (Oscillation Frequency – Target Frequency) × 10 When DEV=1: Oscillation adjustment value = (Oscillation frequency - Target Frequency) Oscillation frequency × 1.017 × 10-6 ≈ (Oscillation Frequency – Target Frequency) × 30 Oscillation adjustment value calculations are exemplified below (A) For an oscillation frequency = 32768.85Hz and a target frequency = 32768.05Hz When setting DEV bit to 0: Oscillation adjustment value = (32768.85 - 32768.05 + 0.1) / (32768.85 × 3.051 × 10-6) ≈ (32768.85 - 32768.05) × 10 + 1 = 9.001 ≈ 9 In this instance, write the settings (DEV,F6,F5,F4,F3,F2,F1,F0)=(0,0,0,0,1,0,0,1) in the oscillation adjustment register. Thus, an appropriate oscillation adjustment value in the presence of any time count gain represents a distance from 01h. When setting DEV bit to 1: Oscillation adjustment value = (32768.85 - 32768.05 + 0.0333) / (32768.85 × 1.017 × 10-6) ≈ (32768.85 - 32768.05) × 30 + 1 = 25.00 ≈ 25 In this instance, write the settings (DEV,F6,F5,F4,F3,F2,F1,F0)=(1,0,0,1,1,0,0,1) in the oscillation adjustment register. (B) For an oscillation frequency = 32762.22Hz and a target frequency = 32768.05Hz When setting DEV bit to 0: Oscillation adjustment value = (32762.22 - 32768.05) / (32762.22 × 3.051 × 10-6) ≈ (32762.22 - 32768.05) × 10 = -58.325 ≈ -58 To represent an oscillation adjustment value of - 58 in 7-bit coded decimal notation, subtract 58 (3Ah) from 128 (80h) to obtain 46h. In this instance, write the settings of (DEV,F6,F5,F4,F3,F2,F1,F0) = (0,1,0,0,0,1,1,0) in the oscillation adjustment register. Thus, an appropriate oscillation adjustment value in the presence of any time count loss represents a distance from 80h. When setting DEV bit to 1: Oscillation adjustment value = (32762.22 - 32768.05) / (32762.22 × 1.017 × 10-6) ≈ (32762.22 - 32768.05) × 30 = -174.97 ≈ -175 Oscillation adjustment value can be set from -62 to 63. range. Then, in this case, Oscillation adjustment value is out of (4) Difference between DEV=0 and DEV=1 Difference between DEV=0 and DEV=1 is following, Maximum value range Minimum resolution DEV=0 -189.2ppm to +189.2ppm 3ppm DEV=1 -62ppm to +63ppm 1ppm 39 R2051 Series Notes: 1) Oscillation adjustment circuit does not affect the frequency of 32.768-kHz clock pulses output from the CLKOUT pin. 2) If following 3 conditions are completed, actual clock adjustment value could be different from target adjustment value that set by oscillator adjustment function. 1. Using oscillator adjustment function 2. Access to R2051 at random, or synchronized with external clock that has no relation to R2051, or synchronized with periodic interrupt in pulse mode. 3. Access to R2051 more than 2 times per each second on average. For more details, please contact to Ricoh. • How to evaluate the clock gain or loss The oscillator adjustment circuit is configured to change time counts of 1 second on the basis of the settings of the oscillation adjustment register once in 20 seconds or 60 seconds. The oscillation adjustment circuit does not effect the frequency of 32768Hz-clock pulse output from the CLKOUT pin. Therefore, after writing the oscillation adjustment register, we cannot measure the clock error with probing CLKOUT clock pulses. The way to measure the clock error as follows (except R2051Txx): (1) Output a 1Hz clock pulse of Pulse Mode with interrupt pin Set (0,0,x,x,0,0,1,1) to Control Register 1 at address Eh. (2) After setting the oscillation adjustment register, 1Hz clock period changes every 20seconds ( or every 60 seconds) like next page figure. 1Hz clock pulse T0 T0 T0 19 times Measure the interval of T0 and T1 with frequency counter. recommended for the measurement. (3) Calculate the typical period from T0 and T1 T = (19×T0+1×T1)/20 Calculate the time error from T. 40 T1 1 time A frequency counter with 7 or more digits is R2051 Series Power-on Reset, Oscillation Halt Sensing, and Supply Voltage Monitoring • PON, XST , and VDET The power-on reset circuit is configured to reset control register1, 2, and clock adjustment register when VDD power up from 0v. The oscillation halt sensing circuit is configured to record a halt on oscillation by 32.768-kHz clock pulses. The supply voltage monitoring circuit is configured to record a drop in supply voltage below a threshold voltage of 2.1 or 1.35v. Each function has a monitor bit. I.e. the PON bit is for the power-on reset circuit, and XST bit is for the oscillation halt sensing circuit, and VDET is for the supply voltage monitoring circuit. PON and VDET bits are activated to “H”. However, XST bit is activated to “L”. The PON and VDET accept only the writing of 0, but XST accepts the writing of 0 and 1. The PON bit is set to 1, when VDD power-up from 0V, but VDET is set to 0, and XST is indefinite. The functions of these three monitor bits are shown in the table below. PON Monitoring for the power-on reset function Function Address Activated When VDD power up from 0v accept the writing D4 in Address Fh High 1 XST Monitoring for the oscillation halt sensing function D5 in Address Fh Low Indefinite VDET a drop in supply voltage below a threshold voltage of 2.1 or 1.35v D6 in Address Fh High 0 0 only Both 0 and 1 0 only The relationship between the PON, XST , and VDET is shown in the table below. PON XST VDET 0 0 0 0 0 1 0 1 0 0 1 1 1 * * Conditions of supply voltage and oscillation Halt on oscillation, but no drop in VDD supply voltage below threshold voltage Halt on oscillation and drop in VDD supply voltage below threshold voltage, but no drop to 0V No drop in VDD supply voltage below threshold voltage and no halt in oscillation Drop in VDD supply voltage below threshold voltage and no halt on oscillation Drop in supply voltage to 0v Condition of oscillator, and back-up status Halt on oscillation cause of condensation etc. Halt on oscillation cause of drop in back-up battery voltage Normal condition No halt on oscillation, but drop in back-up battery voltage Power-up from 0v, 41 R2051 Series Threshold voltage (2.1V or 1.35V) VDD 32768Hz Oscillation Power-on reset flag (PON) Oscillation halt sensing flag (XST) VDD supply voltage monitor flag (VDET) Internal initialization period (1 to 2 sec.) VDET←0 XST←1 PON←0 VDET←0 XST←1 PON←1 Internal initialization period (1 to 2 sec.) VDET←0 XST←1 PON←0 When the PON bit is set to 1 in the control register 2, the DEV, F6 to F0, WALE, DALE, 12 /24, SCRATCH2, TEST, CT2, CT1, CT0, VDSL, VDET, SCRATCH1, CTFG, WAFG, and DAFG bits are reset to 0 in the oscillation adjustment register, the control register 1, and the control register 2. The PON bit is also set to 1 at power-on from 0 volts. < Considerations in Using Oscillation Halt Sensing Circuit > Be sure to prevent the oscillation halt sensing circuit from malfunctioning by preventing the following: 1) Instantaneous power-down on the VDD 2) Condensation on the quartz crystal unit 3) On-board noise to the quartz crystal unit 4) Applying to individual pins voltage exceeding their respective maximum ratings In particular, note that the XST bit may fail to be set to 0 in the presence of any applied supply voltage as illustrated below in such events as backup battery installation. Further, give special considerations to prevent excessive chattering in the oscillation halt sensing circuit. VDD 42 R2051 Series • Voltage Monitoring Circuit R2051S/Kxx incorporates two kinds of voltage monitoring function. (R2051Txx incorporates one kind only.) These are shown in the table below. VCC Voltage Monitoring VDD Voltage Monitoring Circuit (except R2051Txx) Circuit (VDET) Purpose CPU reset output Back-up battery checker Monitoring supply voltage VCC pin VDD pin (supply voltage for the internal RTC circuit) Output for result Store in the Control Register 2 VDCC pin (D6 in Address Fh) Function After falling VCC, VDCC outputs “L”. tDEALY after rising VCC, VDCC outputs “H” (OFF) Below the threshold voltage, SW1 turns off and SW2 turns on. Over the threshold voltage, SW1 turns on and SW2 turns off. Detector Threshold (falling -VDET1 Selecting from VDETH or VDETL by edge of power supply voltage) writing to the register (D7 in Address Fh) Detector Released +VDET1 Same as falling edge Voltage (rising edge of power ( No hysteresis) supply voltage) The way to monitor Always One time every second The VDD supply voltage monitoring circuit is configured to conduct a sampling operation during an interval of 7.8ms per second to check for a drop in supply voltage below a threshold voltage of 2.1 or 1.35v for the VDSL bit setting of 0 (the default setting) or 1, respectively, in the Control Register 2, thus minimizing supply current requirements as illustrated in the timing chart below. This circuit suspends a sampling operation once the VDET bit is set to 1 in the Control Register 2. The VDD supply voltage monitor is useful for back-up battery checking. VDD 2.1v or 1.35v 7.8ms PON Internal nitialization period (1 to 2sec.) 1s Sampling timing for VDD supply voltage monitor VDET (D6 in Address Fh) PON←0 VDET←0 VDET←0 43 R2051 Series The VCC supply voltage monitor circuit operates always. When VCC rising over +VDET1, SW1 turns on, and SW2 turns off. And tDELAY after rising VCC, VDCC outputs OFF(H). But when oscillation is halt, VCC outputs OFF(H) tDELAY after oscillation starting. When VCC falling beyond -VDET1, SW1 turns off, and SW2 turns on. And VDCC outputs “L”. R2051Txx does not have VDCC output pin. Oscillation starting +VDET1 -VDET1 Same voltage level as VSB VCC VDD 32768Hz Oscillation VDCC tDELAY SW1 tDELAY ON tDELAY ON SW2 ON ON ON Battery Switch Over Circuit R2051 incorporates three power supply pins, VDD, VCC, and VSB. VDD pin is the power supply pin for internal real time clock circuit. When VCC voltage is lower than ±VDET1, VSB supplies the power to VDD, and when higher than ±VDET1, VCC supplies the power to VDD. The timing chart for VCC, VDD, and VSB is shown following. +VDET1 -VDET1 VCC VSB VDD (1) (2) (3) (2) (3) (1) When VSB is 0v and VCC is rising from 0v, VDD follows half of VCC voltage level. +VDET1, VDD follows VCC voltage level. (2) When VCC is higher than +VDET1, VDD level is equal to VCC. (3) After VCC falling beyond -VDET1, VDD level is equal to VSB. 44 After VCC rising over R2051 Series Alarm and Periodic Interrupt The R2051 incorporates the alarm interrupt circuit and the periodic interrupt circuit that are configured to generate alarm signals and periodic interrupt signals for output from the INTR pin as described below. R2051Txx has these functions registers, but does not have the INTR output pin. (1) Alarm Interrupt Circuit The alarm interrupt circuit is configured to generate alarm signals for output from the INTR , which is driven low (enabled) upon the occurrence of a match between current time read by the time counters (the day-of-week, hour, and minute counters) and alarm time preset by the alarm registers (the Alarm_W registers intended for the day-of-week, hour, and minute digit settings and the Alarm_D registers intended for the hour and minute digit settings). (2) Periodic Interrupt Circuit The periodic interrupt circuit is configured to generate either clock pulses in the pulse mode or interrupt signals in the level mode for output from the INTR pin depending on the CT2, CT1, and CT0 bit settings in the control register 1. The above two types of interrupt signals are monitored by the flag bits (i.e. the WAFG, DAFG, and CTFG bits in the Control Register 2) and enabled or disabled by the enable bits (i.e. the WALE, DALE, CT2, CT1, and CT0 bits in the Control Register 1) as listed in the table below. Alarm_W Alarm_D Peridic interrupt * * Flag bits WAFG (D1 at Address Fh) DAFG (D0 at Address Fh) CTFG (D2 at Address Fh) Enable bits WALE (D7 at Address Eh) DALE (D6 at Address Eh) CT2=CT1=CT0=0 (These bit setting of “0” disable the Periodic Interrupt) (D2 to D0 at Address Eh) At power-on, when the WALE, DALE, CT2, CT1, and CT0 bits are set to 0 in the Control Register 1, the INTR pin is driven high (disabled). When two types of interrupt signals are output simultaneously from the INTR pin, the output from the INTR pin becomes an OR waveform of their negative logic. Example: Combined Output to /INTR Pin Under Control of ALARM_D and Periodic Interrupt Alarm_D Periodic Interrupt INTR In this event, which type of interrupt signal is output from the INTR pin can be confirmed by reading the DAFG, and CTFG bit settings in the Control Register 2. • Alarm Interrupt The alarm interrupt circuit is controlled by the enable bits (i.e. the WALE and DALE bits in the Control Register 1) and the flag bits (i.e. the WAFG and DAFG bits in the Control Register 2). The enable bits can be used to enable this circuit when set to 1 and to disable it when set to 0. When intended for reading, the flag bits can be used to monitor alarm interrupt signals. When intended for writing, the flag bits will cause no event when set to 1 and will 45 R2051 Series drive high (disable) the alarm interrupt circuit when set to 0. The enable bits will not be affected even when the flag bits are set to 0. In this event, therefore, the alarm interrupt circuit will continue to function until it is driven low (enabled) upon the next occurrence of a match between current time and preset alarm time. The alarm function can be set by presetting desired alarm time in the alarm registers (the Alarm_W Registers for the day-of-week digit settings and both the Alarm_W Registers and the Alarm_D Registers for the hour and minute digit settings) with the WALE and DALE bits once set to 0 and then to 1 in the Control Register 1. Note that the WALE and DALE bits should be once set to 0 in order to disable the alarm interrupt circuit upon the coincidental occurrence of a match between current time and preset alarm time in the process of setting the alarm function. Interval (1min.) during which a match between current time and preset alarm time occurs INTR WALE←1 current time = WALE←0 preset alarm time (DALE) (DALE) WALE←1 (DALE) current time = preset alarm time INTR WALE←1 current time = preset alarm time (DALE) WAFG←0 (DAFG) current time = preset alarm time After setting WALE(DALE) to 0, Alarm registers is set to current time, and WALE(DALE) is set to 1, INTR will be not driven to “L” immediately, INTR will be driven to “L” at next alarm setting time. • Periodic Interrupt Setting of the periodic selection bits (CT2 to CT0) enables periodic interrupt to the CPU. There are two waveform modes: pulse mode and level mode. In the pulse mode, the output has a waveform duty cycle of around 50%. In the level mode, the output is cyclically driven low and, when the CTFG bit is set to 0, the output is return to High (OFF). CT2 CT1 CT0 Wave form mode 46 0 0 0 0 1 0 0 1 1 0 0 1 0 1 0 Pulse Mode *1) Pulse Mode *1) Level Mode *2) 1 0 1 Level Mode *2) 1 1 0 Level Mode *2) 1 1 1 Level Mode *2) Description Interrupt Cycle and Falling Timing OFF(H) Fixed at “L” 2Hz(Duty50%) 1Hz(Duty50%) Once per 1 second (Synchronized with Second counter increment) Once per 1 minute (at 00 seconds of every Minute) Once per hour (at 00 minutes and 00 Seconds of every hour) Once per month (at 00 hours, 00 minutes, and 00 seconds of first day of every month) (Default) R2051 Series *1) Pulse Mode: 2-Hz and 1-Hz clock pulses are output in synchronization with the increment of the second counter as illustrated in the timing chart below. CTFG Bit INTR Pin Approx. 92µs (Increment of second counter) Rewriting of the second counter In the pulse mode, the increment of the second counter is delayed by approximately 92 µs from the falling edge of clock pulses. Consequently, time readings immediately after the falling edge of clock pulses may appear to lag behind the time counts of the real-time clocks by approximately 1 second. Rewriting the second counter will reset the other time counters of less than 1 second, driving the INTR pin low. *2) Level Mode: Periodic interrupt signals are output with selectable interrupt cycle settings of 1 second, 1 minute, 1 hour, and 1 month. The increment of the second counter is synchronized with the falling edge of periodic interrupt signals. For example, periodic interrupt signals with an interrupt cycle setting of 1 second are output in synchronization with the increment of the second counter as illustrated in the timing chart below. CTFG Bit INTR Pin Setting CTFG bit to 0 (Increment of second counter) (Increment of second counter) Setting CTFG bit to 0 (Increment of second counter) *1), *2) When the oscillation adjustment circuit is used, the interrupt cycle will fluctuate once per 20sec. as follows: Pulse Mode: The “L” period of output pulses will increment or decrement by a maximum of ±3.784ms. For example, 1-Hz clock pulses will have a duty cycle of 50 ±0.3784%. Level Mode: A periodic interrupt cycle of 1 second will increment or decrement by a maximum of ±3.784 ms. 47 R2051 Series Typical Applications • Typical Power Circuit Configurations The case of back-up by primary battery VCC The case of back-up by capacitor or secondary battery (Charging voltage is equal to CPU power supply voltage) CPU Power Supply VDD CPU power supply VCC VSB 0.1µF The case of back-up by capacitor or secondary battery (Charging voltage is not equal to CPU power supply voltage) CPU power supply (3V) VCC VSB VSB VDD VDD 0.1 µF 0.1 µF CR2025 etc. Double layer capacitor etc. ML614 etc. VSS VSS VSS VDD pin cannot be connected to any additional heavy load components such as SRAM. connected C2, and C2 should be over 0.1µF. C2 Vbat And VDD pin must be CPU power supply R2051 Series R1 5V VDD SW2 SW1 VSB VCC C3 VOLTAGE DETECTOR -VDET1 CPU Rcpu When secondary battery or double layer capacitor connects to VDD pin, after CPU power supply turning off, secondary battery discharges through the root above figure. If R1 is much smaller than CPU impedance (Rcpu), VCC voltage keeps higher than -VDET1, and SW1 keeps on. Therefore R1 must be specified by following formula. R1 > Rcpu x (Vbat - (-VDET1)) / (-VDET1) R1 is specified by back-up battery or double layer capacitor, too. devices. 48 Please check the data sheet for back-up R2051 Series • Connection of CIN pin Please connect capacitor over 0.1µF between CIN and VSS pin. • Connection of INTR and VDCC Pin (except R2051Txx) The INTR and VDCC pins follow the N-channel open drain output logic and contains no protective diode on the power supply side. As such, it can be connected to a pull-up resistor of up to 5.5 volts regardless of supply voltage. System power supply A INTR or VDCC *1) B OSCIN OSCOUT Backup power supply 32768Hz *1) Depending on whether the INTR and VDCC pins are to be used during battery backup, it should be connected to a pull-up resistor at the following different positions: (1) Position A in the left diagram when it is not to be used during battery backup. (2) Position B in the left diagram when it is to be used during battery backup. VSB VSS 49 R2051 Series Typical Characteristics • Time keeping current (ISB) vs. Supply voltage (VSB) Time keeping current (uA) (Topt=25°C) Test Circuit 0.5 VCC OSCIN 0.4 INTR OSCOUT 0.3 VDCC VSB CLKOUT VDD 0.2 0.1µF 0.1 SCL CIN SDA VSS 0 0 • 1 2 3 VSB(v) 4 5 6 0.1µF Stand-by current (ICC) vs. Supply voltage (VCC) (Topt=25°C) Test circuit Stand-by current (uA) 4 R2051x01 3 2 A VCC OSCIN INTR OSCOUT VDCC VSB CLKOUT VDD R2051S03 1 0.1µF SCL CIN SDA VSS 0 2 3 4 5 6 VCC(v) • A 0.1µF Time keeping current (ISB) vs. Operating Temperature (Topt) (VSB=3V) Test circuit Time keeping current (uA) 0.7 VCC OSCIN INTR OSCOUT 0.6 0.5 0.4 VDCC VSB CLKOUT VDD 0.3 0.2 0.1µF 0.1 SCL CIN SDA VSS 0 -50 50 A -25 0 25 50 75 Operating Temperature (Celsius) 100 0.1µF R2051 Series • Stand-by current (ICC) vs. Operating Temperature (Topt) Test circuit Stand-by current(uA) 6 5 4 A OSCIN INTR OSCOUT 3 2 VDCC VSB CLKOUT VDD VCC=3v(R2051x01/02) 1 0.1µF 0 -50 -25 0 25 50 75 100 Operating temperature (Celsius) • VCC VCC=5v SCL CIN SDA VSS 0.1µF CPU access current vs. SCL clock frequency (kHz) (Topt=25°C) CPU access current (uA) 40 VCC=5v 30 20 VCC=3v 10 0 0 100 200 300 400 500 SCL clock frequency (KHz) Oscillation frequency deviation (∆f/f0) vs. Operating temperature (Topt) (VCC=3V) Topt=25°C as standard Test circuit 20 0 -20 -40 -60 -80 -100 -120 -140 -160 Oscillation frequency deviation df/f0(ppm) • Frequency counter -50 -25 0 25 50 75 VCC OSCIN INTR OSCOUT VDCC VSB CLKOUT VDD 0.1µF SCL CIN SDA VSS 0.1µF 100 Operating temperature Topt(°C) 51 R2051 Series • Frequency deviation (∆f/f0) vs. Supply voltage (VSB/VCC) Frequency deviation df/f0(ppm) (Topt=25°C) VCC/VSB=3V as standard Test circuit 2 0 -1 OSCIN INTR OSCOUT VDCC VSB CLKOUT VDD -2 Frequency counter -3 0.1µF -4 0 1 2 3 4 5 SCL CIN SDA VSS 0.1µF 6 VCC/VSB(v) • VCC 1 Frequency deviation (∆f/f0) vs. CGout Frequency deviation df/f0(ppm) (Topt=25°C, VCC=3V) CGout=0pF as standard Test circuit 10 VCC OSCIN 0 INTR OSCOUT -10 -20 Frequency counter -30 VDCC VSB CLKOUT VDD 0.1µF SCL CIN SDA VSS -40 0 5 10 15 20 0.1µF CGout(pF) • Detector threshold voltage (+VDET1/-VDET1) vs. Operating temperature (Topt) (R2051x01) (R2051x02) 3 Detector threshold voltage ±VDET1(V) Detector threshold voltage ±VDET1(V) 2.6 +VDET1 2.5 -VDET1 2.4 2.3 +VDET1 2.9 2.8 -VDET1 2.7 -50 -25 0 25 50 75 Operating temperature Topt(°C) 52 (VSB=3V) 100 -50 -25 0 25 50 75 Operating temperature Topt(°C) 100 R2051 Series (R2051S03) Test circuit Detector threshold voltage ±VDET1(V) 4.4 4.3 +VDET1 4.2 OSCIN INTR OSCOUT 4.1 -VDET1 4 3.9 VDCC VSB CLKOUT VDD 0.1µF 3.8 -50 -25 0 25 50 75 100 Operating temperature Topt(°C) • VCC SCL CIN SDA VSS 0.1µF VCC-VDD(VDDOUT1) vs. Output load current (IOUT1) (Topt=25°C) Test circuit 0 -0.1 VCC-VDD(V) VCC OSCIN INTR OSCOUT VCC=5V -0.2 VCC=3V -0.3 VDCC VSB CLKOUT VDD VCC=2.5V -0.4 A 0.1µF -0.5 0 2 4 6 8 Output load current IOUT1(mA) CIN SDA VSS 0.1µF VSB-VDD(VDDOUT2) vs. Output load current (IOUT2) (Topt=25°C) Test circuit 0 -0.1 VSB-VDD(V) • SCL 10 -0.2 VSB=3V -0.3 -0.4 VSB=1V VCC OSCIN INTR OSCOUT VDCC VSB CLKOUT VDD -0.5 -0.6 VSB=2V -0.7 A 0.1µF -0.8 0 0.5 1 1.5 2 2.5 Output load current IOUT2(mA) SCL CIN SDA VSS 3 0.1µF 53 R2051 Series • VOL vs. IOL ( VDCC pin) (Except R2051Txx) • VOL vs. IOL ( INTR pin) (Except R2051Txx) (Topt=25°C) 0.8 0.4 0.6 0.3 VOL(v) VOL(v) (Topt=25°C, VSB=VCC=2V) 0.4 0.2 VCC=5V 0.1 0 0 0 2 4 6 IOL(mA) 54 VCC=3V 0.2 8 10 0 2 4 6 IOL(mA) 8 10 R2051 Series Typical Software-based Operations • Initialization at Power-on Start *1) Power-on *2) PON=1? Yes No *3) *4) VDET=0? Set Oscillation Adjustment Register and Control Register 1 and 2, etc. No Yes Warning Back-up Battery Run-down *1) After power-on from 0 volt, the process of internal initialization require a time span on 1sec, so that access should be done after VDCC turning to OFF(H). *2) The PON bit setting of 0 in the Control Register 1 indicates power-on from backup battery and not from 0v. For further details, see "P.41 ■Power-on Reset, Oscillation Halt Sensing, and Supply Voltage Monitoring •PON, XST , and VDET ". *3) This step is not required when the supply voltage monitoring circuit is not used. *4) This step involves ordinary initialization including the Oscillation Adjustment Register and interrupt cycle settings, etc. • Writing of Time and Calendar Data *1) Start Condition Write to Time Counter and Calendar Counter Stop Condition *2) *3) *1) When writing to clock and calendar counters, do not insert Stop Condition until all times from second to year have been written to prevent error in writing time. (Detailed in "P.34 Data Transmission under Special Condition". *2) Any writing to the second counter will reset divider units lower than the second digits. *3) Take care so that process from Start Condition to Stop Condition will be complete within 0.5sec. (Detailed in "P.34 Data Transmission under Special Condition". The R2051 may also be initialized not at power-on but in the process of writing time and calendar data. 55 R2051 Series • Reading Time and Calendar Data (1) Ordinary Process of Reading Time and Calendar Data *1) Start Condition Read from Time Counter and Calendar Counter *1) When reading to clock and calendar counters, do not insert Stop Condition until all times from second to year have been written to prevent error in writing time. (Detailed in "P.34 Data Transmission under Special Condition". *2) Take care so that process from Start Condition to Stop Condition will be complete within 0.5sec. (Detailed in "P.34 Data Transmission under Special Condition". *2) Stop Condition (2) Basic Process of Reading Time and Calendar Data with Periodic Interrupt Function Set Periodic Interrupt Cycle Selection Bits *1) Generate Interrupt in CPU No CTFG=1? Yes *2) Read from Time Counter and Calendar Counter *3) Control Register 2 ←(X1X1X011) 56 Other Interrupt Processes *1) This step is intended to select the level mode as a waveform mode for the periodic interrupt function. *2) This step must be completed within 0.5 second. *3) This step is intended to set the CTFG bit to 0 in the Control Register 2 to cancel an interrupt to the CPU. R2051 Series (3) Applied Process of Reading Time and Calendar Data with Periodic Interrupt Function (Except R2051Txx) Time data need not be read from all the time counters when used for such ordinary purposes as time count indication. This applied process can be used to read time and calendar data with substantial reductions in the load involved in such reading. For Time Indication in "Day-of-Month, Day-of-week, Hour, Minute, and Second" Control Register 1 ← (XXXX0100) Control Register 2 ← (X1X1X011) *1) Generate interrupt to CPU Yes Other interrupts Processes No CTFG=1? *2) Sec.=00? Control Register 2← (X1X1X011) *1) This step is intended to select the level mode as a waveform mode for the periodic interrupt function. *2) This step must be completed within 0.5 sec. *3) This step is intended to read time data from all the time counters only in the first session of reading time data after writing time data. *4) This step is intended to set the CTFG bit to 0 in the Control Register 2 to cancel an interrupt to the CPU. No Yes Read Min.,Hr.,Day, and Day-of-week Format: *3) Use previous Min.,Hr., Day, and Day-of-week data *4) 57 R2051 Series • Interrupt Process (1) Periodic Interrupt (except R2051Txx) Set Periodic Interrupt Cycle Selection Bits *1) *1) This step is intended to select the level mode as a waveform mode for the periodic interrupt function. *2) This step is intended to set the CTFG bit to 0 in the Control Register 2 to cancel an interrupt to the CPU. Generate Interrupt to CPU No CTFG=1? Yes Other Interrupt Processes Conduct Periodic Interrupt *2) Control Register 2← (X1X1X011) (2) Alarm Interrupt (except R2051Txx) WALE or DALE←0 *1) *1) This step is intended to once disable the alarm interrupt circuit by setting the WALE or DALE bits to 0 in anticipation of the coincidental occurrence of a match between current time and preset alarm time in the process of setting the alarm interrupt function. *2) This step is intended to enable the alarm interrupt function after completion of all alarm interrupt settings. *3) This step is intended to once cancel the alarm interrupt function by writing the settings of "X,1,X, 1,X,1,0,1" and "X,1,X,1,X,1,1,0" to the Alarm_W Registers and the Alarm_D Registers, respectively. Set Alarm Min., Hr., and Day-of-week Registers WALE or DALE←1 *2) Generate Interrupt to CPU No Other Interrupt WAFG or DAFG=1? Processes Yes Conduct Alarm Interrupt *3) Control Register 2 ← (X1X1X101) 58