SAMSUNG S3C94A5

S3C94A5/F94A5
8-BIT CMOS
MICROCONTROLLER
USER'S MANUAL
Revision 1.1
Important Notice
The information in this publication has been carefully
checked and is believed to be entirely accurate at the
time of publication. Samsung assumes no
responsibility, however, for possible errors or
omissions, or for any consequences resulting from
the use of the information contained herein.
Samsung reserves the right to make changes in its
products or product specifications with the intent to
improve function or design at any time and without
notice and is not required to update this
documentation to reflect such changes.
This publication does not convey to a purchaser of
semiconductor devices described herein any license
under the patent rights of Samsung or others.
Samsung makes no warranty, representation, or
guarantee regarding the suitability of its products for
any particular purpose, nor does Samsung assume
any liability arising out of the application or use of any
product or circuit and specifically disclaims any and
all liability, including without limitation any
consequential or incidental damages.
"Typical" parameters can and do vary in different
applications. All operating parameters, including
"Typicals" must be validated for each customer
application by the customer's technical experts.
Samsung products are not designed, intended, or
authorized for use as components in systems
intended for surgical implant into the body, for other
applications intended to support or sustain life, or for
any other application in which the failure of the
Samsung product could create a situation where
personal injury or death may occur.
Should the Buyer purchase or use a Samsung
product for any such unintended or unauthorized
application, the Buyer shall indemnify and hold
Samsung and its officers, employees, subsidiaries,
affiliates, and distributors harmless against all claims,
costs, damages, expenses, and reasonable attorney
fees arising out of, either directly or indirectly, any
claim of personal injury or death that may be
associated with such unintended or unauthorized use,
even if such claim alleges that Samsung was
negligent regarding the design or manufacture of said
product.
S3C94A5/F94A5 8-Bit CMOS Microcontroller
User's Manual, Revision 1.1
Publication Number: 21.1-S3-C94A5/F94A5-072005
© 2005 Samsung Electronics
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
form or by any means, electric or mechanical, by photocopying, recording, or otherwise, without the prior written
consent of Samsung Electronics.
Samsung Electronics' microcontroller business has been awarded full ISO-14001
certification (BVQ1 Certificate No. 9330). All semiconductor products are designed and
manufactured in accordance with the highest quality standards and objectives.
Samsung Electronics Co., Ltd.
San #24 Nongseo-Ri, Giheung- Eup
Yongin-City, Gyeonggi-Do, Korea
C.P.O. Box #37, Suwon 449-900
TEL:
(82)-(031)-209-1934
FAX:
(82) (331) 209-1889
Home-Page URL: Http://www.samsungsemi.com/
Printed in the Republic of Korea
NOTIFICATION OF REVISIONS
ORIGINATOR:
Samsung Electronics, LSI Development Group, Ki-Heung, South Korea
PRODUCT NAME:
S3C94A5/F94A5 8-bit CMOS Microcontroller
DOCUMENT NAME:
S3C94A5/F94A5 User's Manual, Revision 1.1
DOCUMENT NUMBER:
21.1-S3-C94A5/F94A5-072005
EFFECTIVE DATE:
July, 2005
SUMMARY:
As a result of additional product testing and evaluation, some specifications
published in the S3C94A5/F94A5 User's Manual, Revision 1, have been
changed. These changes for S3C94A5/F94A5 microcontroller, which are
described in detail in the Revision Descriptions section below, are related to the
followings:
— Chapter 17. Electrical Data
DIRECTIONS:
Please note the changes in your copy (copies) of the S3C94A5/F94A5 User's
Manual, Revision 1. Or, simply attach the Revision Descriptions of the next
page to S3C94A5/F94A5 User's Manual, Revision 1.
REVISION HISTORY
Revision
Date
0
July, 2004
1
February, 2005
1.1
July, 2005
Remark
Preliminary spec for internal release only.
First edition. Reviewed by Finechips.
Second edition. Reviewed by Finechips.
REVISION DESCRIPTIONS
1. ELECTRICAL DATA
Table 17-1. Absolute Maximum Ratings
(TA = 25°C)
Parameter
Symbol
Conditions
Rating
Unit
VDD
–
– 0.3 to + 6.5
V
– 0.3 to VDD + 0.3
V
– 0.3 to VDD + 0.3
V
Supply voltage
Input voltage
VI
Output voltage
VO
Output current High
IOH
Ports 1–5
–
One I/O pin active
All I/O pins active
Output current Low
IOL
42-SDIP
– 60
44-QFP
– 90
One I/O pin active
All I/O pin active
mA
+ 30
42-SDIP
+ 100
44-QFP
+ 150
mA
TA
–
– 25 to + 85
°C
TSTG
–
– 65 to + 150
°C
Operating
temperature
Storage temperature
– 15
Table 17-9. External RC Oscillation (Mode 2) Characteristics
(TA = – 25 °C to + 85 °C, VDD = 2.7 V to 5.5 V)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
4
–
8
MHz
%
RC oscillator frequency
range (1)
fERC
TA = 25 °C
Accuracy of RC oscillation
ACCERC
VDD = 3.3 V, TA = 25 °C
–7
–
+7
VDD = 3.3 V,
–15
–
+15
–
–
10
(2)
TA = –25 °C to 85 °C
RC oscillator setup time (3)
tSUERC
TA = 25 °C
NOTES:
1. The frequency is adjusted by external resistor.
2. The min/max frequencies are within the range of RC OSC frequency (4 MHz to 8 MHz).
3. Data based on characterization results, not tested in production.
4. The external resistor is connected between VDD and XIN pin (XOUT pin should be open).
ms
Preface
The S3C94A5/F94A5 Microcontroller User's Manual is designed for application designers and programmers who are
using the S3C94A5/F94A5 microcontroller for application development. It is organized in two parts:
Part I
Programming Model
Part II
Hardware Descriptions
Part I contains software-related information to familiarize you with the microcontroller's architecture, programming
model, instruction set, and interrupt structure. It has six chapters:
Chapter 1
Chapter 2
Chapter 3
Product Overview
Address Spaces
Addressing Modes
Chapter 4
Chapter 5
Chapter 6
Control Registers
Interrupt Structure
SAM88RCRI Instruction Set
Chapter 1, "Product Overview," is a high-level introduction to the S3C94A5/F94A5 with a general product description,
and detailed information about individual pin characteristics and pin circuit types.
Chapter 2, "Address Spaces," explains the S3C94A5/F94A5 program and data memory, internal register file, and
mapped control registers, and explains how to address them. Chapter 2 also describes working register addressing,
as well as system and user-defined stack operations.
Chapter 3, "Addressing Modes," contains detailed descriptions of the six addressing modes that are supported by
the CPU.
Chapter 4, "Control Registers," contains overview tables for all mapped system and peripheral control register values,
as well as detailed one-page descriptions in standard format. You can use these easy-to-read, alphabetically
organized, register descriptions as a quick-reference source when writing programs.
Chapter 5, "Interrupt Structure," describes the S3C94A5/F94A5 interrupt structure in detail and further prepares you
for additional information presented in the individual hardware module descriptions in part II.
Chapter 6, "SAM88RCRI Instruction Set," describes the features and conventions of the instruction set used for all
S3C9-series microcontrollers. Several summary tables are presented for orientation and reference. Detailed
descriptions of each instruction are presented in a standard format. Each instruction description includes one or
more practical examples of how to use the instruction when writing an application program.
A basic familiarity with the information in part I will help you to understand the hardware module descriptions in Part
II. If you are not yet familiar with the SAM88RCRI product family and are reading this manual for the first time, we
recommend that you first read chapters 1–3 carefully. Then, briefly look over the detailed information in chapters 4, 5,
and 6. Later, you can reference the information in part I as necessary.
Part II contains detailed information about the peripheral components of the S3C94A5/F94A5 microcontrollers. Also
included in part II are electrical, mechanical, MTP, and development tools data. It has 14 chapters:
Chapter 7
Chapter 8
Chapter 9
Chapter 10
Chapter 11
Chapter 12
Chapter 13
Clock Circuit
RESET and Power-Down
I/O Ports
Basic Timer
16-bit Timer 0
16-bit Timer 1
8-bit Timer 2
Chapter 14
Chapter 15
Chapter 16
Chapter 17
Chapter 18
Chapter 19
Chapter 20
Watch Timer
10-Bit Analog-To-Digital Converter
Serial I/O Interface
Electrical Data
Mechanical Data
S3F94A5 Flash MCU
Development Tools
Two order forms are included at the back of this manual to facilitate customer order for S3C94A5/F94A5
microcontroller: the Mask ROM Order Form, and the Mask Option Selection Form. You can photocopy these forms,
fill them out, and then forward them to your local Samsung Sales Representative.
S3C94A5/F94A5 MICROCONTROLLER
iii
Table of Contents
Part I — Programming Model
Chapter 1
Product Overview
SAM88RCRI Product Family ................................................................................................................1-1
S3C94A5/F94A5 Microcontroller ...........................................................................................................1-1
Flash..................................................................................................................................................1-1
Features .............................................................................................................................................1-2
Block Diagram ....................................................................................................................................1-3
Pin Assignments.................................................................................................................................1-4
Pin Descriptions ..................................................................................................................................1-6
Pin Circuit Diagrams............................................................................................................................1-8
Chapter 2
Address Spaces
Overview .............................................................................................................................................2-1
Program Memory (ROM) ......................................................................................................................2-2
Smart Option ......................................................................................................................................2-3
Register Architecture ...........................................................................................................................2-5
Common Working Register Area (C0H–CFH) .........................................................................................2-6
System Stack.....................................................................................................................................2-7
Chapter 3
Addressing Modes
Overview .............................................................................................................................................3-1
Register Addressing Mode (R) ..............................................................................................................3-2
Indirect Register Addressing Mode (IR)..................................................................................................3-3
Indexed Addressing Mode (X) ...............................................................................................................3-7
Direct Address Mode (DA)....................................................................................................................3-10
Relative Address Mode (RA).................................................................................................................3-12
Immediate Mode (IM) ...........................................................................................................................3-12
S3C94A5/F94A5 MICROCONTROLLER
v
Table of Contents (Continued)
Chapter 4
Control Registers
Overview .............................................................................................................................................4-1
Chapter 5
Interrupt Structure
Overview .............................................................................................................................................5-1
Interrupt Processing Control Points ...............................................................................................5-1
Enable/Disable Interrupt Instructions (EI, DI) ..................................................................................5-1
Interrupt Pending Function Types ..................................................................................................5-2
Interrupt Priority...........................................................................................................................5-2
Interrupt Source Service Sequence................................................................................................5-3
Interrupt Service Routines.............................................................................................................5-3
Generating Interrupt Vector Addresses ..........................................................................................5-3
S3C94A5/F94A5 Interrupt Structure ..............................................................................................5-4
Chapter 6
SAM88RCRI Instruction Set
Overview .............................................................................................................................................6-1
Register Addressing ....................................................................................................................6-1
Addressing Modes.......................................................................................................................6-1
Flags Register (FLAGS)...............................................................................................................6-4
Flag Descriptions ........................................................................................................................6-4
Instruction Set Notation................................................................................................................6-5
Condition Codes ..........................................................................................................................6-9
Instruction Descriptions................................................................................................................6-10
vi
S3C94A5/F94A5 MICROCONTROLLER
Table of Contents (Continued)
Part II — Hardware Descriptions
Chapter 7
Clock Circuit
Overview .............................................................................................................................................7-1
System Clock Circuit...................................................................................................................7-1
CPU Clock Notation.....................................................................................................................7-1
Main Oscillator Circuits................................................................................................................7-2
Clock Status During Power-Down Modes .......................................................................................7-3
System Clock Control Register (CLKCON).....................................................................................7-4
Stop Control Register (STPCON) ..................................................................................................7-5
Chapter 8
RESET and Power-Down
System Reset .....................................................................................................................................8-1
Overview .....................................................................................................................................8-1
Power-Down Modes .............................................................................................................................8-2
Stop Mode..................................................................................................................................8-2
Idle Mode....................................................................................................................................8-3
Hardware Reset Values................................................................................................................8-4
Chapter 9
I/O Ports
Overview .............................................................................................................................................9-1
Port Data Registers .....................................................................................................................9-2
Port 1.........................................................................................................................................9-3
Port 2.........................................................................................................................................9-7
Port 3.........................................................................................................................................9-9
Port 4.........................................................................................................................................9-15
Port 5.........................................................................................................................................9-19
Chapter 10
Basic Timer
Overview .............................................................................................................................................10-1
Basic Timer Control Register (BTCON) ..........................................................................................10-2
Basic Timer Function Description..................................................................................................10-3
S3C94A5/F94A5 MICROCONTROLLER
vii
Table of Contents
Chapter 11
(Continued)
16-bit Timer 0
Overview .............................................................................................................................................11-1
Timer/Counter 0 Control Register (T0CON).....................................................................................11-1
Timer 0 Function Description ........................................................................................................11-4
Chapter 12
16-bit Timer 1
Overview .............................................................................................................................................12-1
Timer/Counter 1 Control Register (T1CON).....................................................................................12-1
Timer 1 Function Description ........................................................................................................12-4
Chapter 13
8-bit Timer 2
Overview .............................................................................................................................................13-1
Timer/Counter 2 Control Register (T2CON).....................................................................................13-1
Timer 2 Function Description ........................................................................................................13-4
Chapter 14
Watch Timer
Overview .............................................................................................................................................14-1
Watch Timer Control Register (WTCON)........................................................................................14-2
Watch Timer Circuit Diagram........................................................................................................14-3
Chapter 15
10-Bit Analog-To-Digital Converter
Overview .............................................................................................................................................15-1
Function Description............................................................................................................................15-1
Conversion Timing .......................................................................................................................15-2
A/D Converter Control Register (ADCON).......................................................................................15-2
Internal Reference Voltage Levels..................................................................................................15-3
Block Diagram ....................................................................................................................................15-4
viii
S3C94A5/F94A5 MICROCONTROLLER
Table of Contents
Chapter 16
(Continued)
Serial I/O Interface
Overview .............................................................................................................................................16-1
Programming Procedure...............................................................................................................16-1
SIO Control Registers (SIOCON)...................................................................................................16-2
SIO Pre-Scaler Register (SIOPS)..................................................................................................16-3
SIO Block Diagram..............................................................................................................................16-3
Serial I/O Timing Diagram (SIO) ....................................................................................................16-4
Chapter 17
Electrical Data
Overview .............................................................................................................................................17-1
Chapter 18
Mechanical Data
Overview .............................................................................................................................................18-1
Chapter 19
S3F94A5 Flash MCU
Overview .............................................................................................................................................19-1
Operating Mode Characteristics....................................................................................................19-5
Chapter 20
Development Tools
Overview .............................................................................................................................................20-1
SHINE ........................................................................................................................................20-1
SAMA Assembler........................................................................................................................20-1
SASM86.....................................................................................................................................20-1
HEX2ROM ..................................................................................................................................20-1
Target Boards .............................................................................................................................20-1
TB94A5 Target Board...................................................................................................................20-3
SMDS2+ Selection (SAM8)..........................................................................................................20-5
Idle LED .....................................................................................................................................20-5
Stop LED....................................................................................................................................20-5
S3C94A5/F94A5 MICROCONTROLLER
ix
List of Figures
Figure
Number
Title
Page
Number
1-1
1-2
1-3
1-4
1-5
1-6
1-7
1-8
1-9
Block Diagram ....................................................................................................1-3
S3C94A5/F94A5 Pin Assignments (44-QFP-1010B)...............................................1-4
S3C94A5/F94A5 Pin Assignments (42-SDIP-600) ..................................................1-5
Pin Circuit Type B (nRESET) ................................................................................1-8
Pin Circuit Type E ...............................................................................................1-8
Pin Circuit Type E-2 (P5.1–P5.6) ..........................................................................1-9
Pin Circuit Type E-4 (P1, P4.2–P4.6) ....................................................................1-9
Pin Circuit Type F-16 (P2, P5.0) ...........................................................................1-10
Pin Circuit Type F-16A (P3, P4.0, P4.1, P4.7)........................................................1-10
2-1
2-2
2-3
2-4
2-5
S3C94A5/F94A5 Program Memory Address Space................................................2-2
Smart Option ......................................................................................................2-4
Internal Register File Organization.........................................................................2-5
16-Bit Register Pairs............................................................................................2-6
Stack Operations ................................................................................................2-7
3-1
3-2
3-3
3-4
3-5
3-6
3-7
3-8
3-9
3-10
3-11
3-12
3-13
Register Addressing ............................................................................................3-2
Working Register Addressing ...............................................................................3-2
Indirect Register Addressing to Register File..........................................................3-3
Indirect Register Addressing to Program Memory ...................................................3-4
Indirect Working Register Addressing to Register File.............................................3-5
Indirect Working Register Addressing to Program or Data Memory...........................3-6
Indexed Addressing to Register File ......................................................................3-7
Indexed Addressing to Program or Data Memory with Short Offset ...........................3-8
Indexed Addressing to Program or Data Memory with Long Offset............................3-9
Direct Addressing for Load Instructions..................................................................3-10
Direct Addressing for Call and Jump Instructions ....................................................3-11
Relative Addressing .............................................................................................3-12
Immediate Addressing .........................................................................................3-12
S3C94A5/F94A5 MICROCONTROLLER
xi
List of Figures (Continued)
Figure
Number
Title
Page
Number
4-1
Register Description Format .................................................................................4-4
5-1
5-2
5-3
S3C9-Series Interrupt Type...................................................................................5-1
Interrupt Function Diagram ...................................................................................5-2
S3C94A5/F94A5 Interrupt Structure ......................................................................5-5
6-1
System Flags Register (FLAGS)...........................................................................6-4
7-1
7-2
7-3
7-4
7-5
7-6
7-7
7-8
Crystal/Ceramic Oscillator(fx)...............................................................................7-2
External Oscillator(fx) ..........................................................................................7-2
RC Oscillator(fx)..................................................................................................7-2
External RC Oscillator(fx).....................................................................................7-2
Internal RC Oscillator(fx) ......................................................................................7-2
System Clock Circuit Diagram..............................................................................7-3
System Clock Control Register (CLKCON).............................................................7-4
STOP Control Register (STPCON) ........................................................................7-5
9-1
9-2
9-3
9-4
9-5
9-6
9-7
9-8
9-9
9-10
9-11
9-12
9-13
9-14
9-15
9-16
9-17
9-18
9-19
9-20
9-21
9-22
9-23
9-24
9-25
9-26
9-27
S3C94A5/F94A5 I/O Port Data Register Format .....................................................9-2
Port 1 Control Register, High Byte (P1CONH) ........................................................9-4
Port 1 Control Register, Low Byte (P1CONL) .........................................................9-4
Port 1 Interrupt Control Register (P1INT) ................................................................9-5
Interrupt Pending Register 1 (INTPND1) .................................................................9-5
Port 1 Interrupt Edge Selection Register, High Byte (P1EDGEH) .............................9-6
Port 1 Interrupt Edge Selection Register, Low Byte (P1EDGEL)...............................9-6
Port 2 Control Register, High Byte (P2CONH) ........................................................9-7
Port 2 Control Register, Low Byte (P2CONL) .........................................................9-8
Port 2 Pull-up Control Register (P2PUR)................................................................9-8
Port 3 Control Register, High Byte (P3CONH) ........................................................9-10
Port 3 Control Register, Low Byte (P3CONL) .........................................................9-11
Port 3 Interrupt Control Register (P3INT) ................................................................9-12
Interrupt Pending Register 2 (INTPND2) .................................................................9-12
Port 3 Interrupt Edge Selection Register, High Byte (P3EDGEH) .............................9-13
Port 3 Interrupt Edge Selection Register, Low Byte (P3EDGEL)...............................9-13
Port 3 Pull-up Control Register (P3PUR)................................................................9-14
Port 4 Control Register, High Byte (P4CONH) ........................................................9-16
Port 4 Control Register, Middle Byte (P4CONM).....................................................9-16
Port 4 Control Register, Low Byte (P4CONL) .........................................................9-17
Port 4 Pull-up Control Register (P4PUR)................................................................9-17
Port 4 and 5 Interrupt Control Register (P4n5INT)....................................................9-18
Interrupt Pending Register 2 (INTPND2) .................................................................9-18
Port 5 Control Register, High-Byte (P5CONH) ........................................................9-19
Port 5 Control Register, Low-Byte (P5CONL) .........................................................9-20
Port 4 and 5 Interrupt Control Register (P4n5INT)....................................................9-20
Interrupt Pending Register 2 (INTPND2) .................................................................9-21
xii
S3C94A5/F94A5 MICROCONTROLLER
List of Figures (Continued)
Figure
Number
Title
Page
Number
10-1
10-2
Basic Timer Control Register (BTCON) ..................................................................10-2
Basic Timer Block Diagram ..................................................................................10-4
11-1
11-2
11-3
11-4
11-5
11-6
Timer 0 Control Register (T0CON) .........................................................................11-2
Interrupt Pending Register 3 (INTPND3) .................................................................11-3
Simplified Timer 0 Function Diagram: Interval Timer Mode .......................................11-4
Simplified Timer 0 Function Diagram: PWM Mode ..................................................11-5
Simplified Timer 0 Function Diagram: Capture Mode ...............................................11-6
Timer 0 Block Diagram.........................................................................................11-7
12-1
12-2
12-3
12-4
12-5
12-6
Timer 1 Control Register (T1CON) .........................................................................12-2
Interrupt Pending Register 3 (INTPND3) .................................................................12-3
Simplified Timer 1 Function Diagram: Interval Timer Mode .......................................12-4
Simplified Timer 1 Function Diagram: PWM Mode ..................................................12-5
Simplified Timer 1 Function Diagram: Capture Mode ...............................................12-6
Timer 1 Block Diagram.........................................................................................12-7
13-1
13-2
13-3
13-4
13-5
13-6
Timer 2 Control Register (T2CON) .........................................................................13-2
Interrupt Pending Register 3 (INTPND3) .................................................................13-3
Simplified Timer 2 Function Diagram: Interval Timer Mode .......................................13-4
Simplified Timer 2 Function Diagram: PWM Mode ..................................................13-5
Simplified Timer 2 Function Diagram: Capture Mode ...............................................13-6
Timer 2 Block Diagram.........................................................................................13-7
14-1
14-2
Watch Timer Control Register (WTCON)................................................................14-2
Watch Timer Circuit Diagram................................................................................14-3
S3C94A5/F94A5 MICROCONTROLLER
xiii
List of Figures (Continued)
Figure
Number
Title
Page
Number
15-1
15-2
15-3
15-4
A/D Converter Control Register (ADCON)...............................................................15-2
A/D Converter Data Register (ADDATAH/ADDATAL)...............................................15-3
A/D Converter Functional Block Diagram ...............................................................15-4
Recommended A/D Converter Circuit for Highest Absolute Accuracy........................15-5
16-1
16-2
16-3
16-4
16-5
Serial I/O Module Control Register (SIOCON).........................................................16-2
SIO Prescaler Register (SIOPS) ...........................................................................16-3
SIO Functional Block Diagram..............................................................................16-3
Serial I/O Timing in Transmit/Receive Mode (Tx at falling, SIOCON.4 = 0).................16-4
Serial I/O Timing in Transmit/Receive Mode (Tx at rising, SIOCON.4 = 1) .................16-4
17-1
17-2
17-3
17-4
17-5
17-6
Stop Mode Release Timing When Initiated by an External Interrupt ..........................17-6
Stop Mode Release Timing When Initiated by a RESET..........................................17-7
Input Timing for External Interrupts ........................................................................17-9
Input Timing for nRESET......................................................................................17-10
Serial Data Transfer Timing...................................................................................17-10
Clock Timing Measurement at XIN .........................................................................17-12
17-7
Operating Voltage Range .....................................................................................17-14
18-1
18-2
42-SDIP-600 Package Dimensions........................................................................18-1
44-QFP-1010B Package Dimensions ....................................................................18-2
19-1
19-2
19-3
S3F94A5 Pin Assignments (44-QFP-1010B)..........................................................19-2
S3F94A5 Pin Assignments (42-SDIP-600) .............................................................19-3
Operating Voltage Range .....................................................................................19-7
20-1
20-2
20-3
20-4
20-5
SMDS Product Configuration (SMDS2+)................................................................20-2
TB94A5 Target Board Configuration.......................................................................20-3
Connectors (J101, J102) for TB94A5......................................................................20-6
S3C94A5 Probe Adapter for 42-SDIP Package.......................................................20-7
S3C94A5 Probe Adapter for 44-QFP Package........................................................20-7
xiv
S3C94A5/F94A5 MICROCONTROLLER
List of Tables
Table
Number
Title
Page
Number
1-1
Pin Descriptions ..................................................................................................1-6
4-1
System and Peripheral Control Registers...............................................................4-2
6-1
6-2
6-3
6-4
6-5
6-6
Instruction Group Summary ..................................................................................6-2
Flag Notation Conventions ....................................................................................6-5
Instruction Set Symbols.......................................................................................6-5
Instruction Notation Conventions ...........................................................................6-6
Opcode Quick Reference .....................................................................................6-7
Condition Codes ..................................................................................................6-9
8-1
Register Values after RESET................................................................................8-4
9-1
9-2
S3C94A5 Port Configuration Overview....................................................................9-1
Port Data Register Summary ................................................................................9-2
17-1
17-2
17-3
17-4
17-5
17-6
17-7
17-8
17-9
17-10
Absolute Maximum Ratings..................................................................................17-2
D.C. Electrical Characteristics..............................................................................17-3
Data Retention Supply Voltage in Stop Mode.........................................................17-6
Input/Output Capacitance.....................................................................................17-7
A.C. Electrical Characteristics..............................................................................17-8
A/D Converter Electrical Characteristics ................................................................17-9
Main Oscillation Characteristics............................................................................17-11
Main Oscillator Stabilization Time .........................................................................17-12
External RC Oscillation (Mode 2) Characteristics ...................................................17-13
Internal RC Oscillation Characteristics...................................................................17-13
19-1
19-2
19-3
19-4
Descriptions of Pins Used to Read/Write the Flash ROM ........................................19-4
Comparison of S3F94A5 and S3C94A5 Features....................................................19-4
Operating Mode Selection Criteria.........................................................................19-5
D.C. Electrical Characteristics..............................................................................19-6
20-1
20-2
20-3
20-4
Power Selection Settings for TB94A5....................................................................20-4
Smart Option Switch Settings for TB94A5..............................................................20-4
The SMDS2+ Tool Selection Setting .....................................................................20-5
Using Single Header Pins as the Input Path for External Trigger Sources..................20-5
S3C94A5/F94A5 MICROCONTROLLER
xv
List of Programming Tips
Description
Chapter 2:
Page
Number
Address Spaces
Addressing the Common Working Register Area ................................................................................2-6
Standard Stack Operations Using PUSH and POP.............................................................................2-8
Chapter 5:
Interrupt Structure
How to clear an interrupt pending bit..................................................................................................5-6
Chapter 7:
Clock Circuits
How to Use Stop Instruction .............................................................................................................7-5
S3C94A5/F94A5 MICROCONTROLLER
xvii
List of Register Descriptions
Register
Identifier
ADCON
BTCON
CLKCON
FLAGS
INTPND1
INTPND2
INTPND3
P1CONH
P1CONL
P1INT
P1EDGEH
P1EDGEL
P2CONH
P2CONL
P2PUR
P3CONH
P3CONL
P3INT
P3EDGEH
P3EDGEL
P3PUR
P4CONH
P4CONM
P4CONL
P4n5INT
P4PUR
P5CONH
P5CONL
SIOCON
STPCON
SYM
T0CON
T1CON
T2CON
WTCON
Full Register Name
Page
Number
A/D Converter Control Register .............................................................................4-5
Basic Timer Control Register ................................................................................4-6
System Clock Control Register.............................................................................4-7
System Flags Register ........................................................................................4-8
Interrupt Pending Register 1 .................................................................................4-9
Interrupt Pending Register 2 .................................................................................4-10
Interrupt Pending Register 3 .................................................................................4-11
Port 1 Control Register (High Byte) .......................................................................4-12
Port 1 Control Register (Low Byte) ........................................................................4-13
Port 1 Interrupt Control Register............................................................................4-14
Port 1 Interrupt Edge Selection Register (High Byte)...............................................4-15
Port 1 Interrupt Edge Selection Register (Low Byte)................................................4-16
Port 2 Control Register (High Byte) .......................................................................4-17
Port 2 Control Register (Low Byte) ........................................................................4-18
Port 2 Pull-up Control Register..............................................................................4-19
Port 3 Control Register (High Byte) .......................................................................4-20
Port 3 Control Register (Low Byte) ........................................................................4-21
Port 3 Interrupt Control Register............................................................................4-22
Port 3 Interrupt Edge Selection Register (High Byte)...............................................4-23
Port 3 Interrupt Edge Selection Register (Low Byte)................................................4-24
Port 3 Pull-up Control Register..............................................................................4-25
Port 4 Control Register (High Byte) .......................................................................4-26
Port 4 Control Register (Middle Byte) ....................................................................4-27
Port 4 Control Register (Low Byte) ........................................................................4-28
Port 4 and 5 Interrupt Control Register...................................................................4-29
Port 4 Pull-up Control Register..............................................................................4-30
Port 5 Control Register (High Byte) .......................................................................4-31
Port 5 Control Register (Low Byte) ........................................................................4-32
SIO Control Register............................................................................................4-33
Stop Control Register...........................................................................................4-34
System Mode Register ........................................................................................4-35
Timer 0 Control Register.......................................................................................4-36
Timer 1 Control Register.......................................................................................4-37
Timer 2 Control Register.......................................................................................4-38
Watch Timer Control Register...............................................................................4-39
S3C94A5/F94A5 MICROCONTROLLER
xix
List of Instruction Descriptions
Instruction
Mnemonic
ADC
ADD
AND
CALL
CCF
CLR
COM
CP
DEC
DI
EI
IDLE
INC
IRET
JP
JR
LD
LDC/LDE
LDCD/LDED
LDCI/LDEI
NOP
OR
POP
PUSH
RCF
RET
RL
RLC
RR
RRC
SBC
SCF
SRA
STOP
SUB
TCM
TM
XOR
Full Instruction Name
Page
Number
Add With Carry ...................................................................................................6-11
Add....................................................................................................................6-12
Logical AND........................................................................................................6-13
Call Procedure ....................................................................................................6-14
Complement Carry Flag .......................................................................................6-15
Clear ..................................................................................................................6-16
Complement .......................................................................................................6-17
Compare.............................................................................................................6-18
Decrement ..........................................................................................................6-19
Disable Interrupts ................................................................................................6-20
Enable Interrupts .................................................................................................6-21
Idle Operation......................................................................................................6-22
Increment ...........................................................................................................6-23
Interrupt Return ...................................................................................................6-24
Jump..................................................................................................................6-25
Jump Relative......................................................................................................6-26
Load...................................................................................................................6-27
Load Memory ......................................................................................................6-29
Load Memory and Decrement ...............................................................................6-31
Load Memory and Increment ................................................................................6-32
No Operation.......................................................................................................6-33
Logical OR..........................................................................................................6-34
Pop From Stack..................................................................................................6-35
Push To Stack ....................................................................................................6-36
Reset Carry Flag .................................................................................................6-37
Return ................................................................................................................6-38
Rotate Left ..........................................................................................................6-39
Rotate Left Through Carry.....................................................................................6-40
Rotate Right........................................................................................................6-41
Rotate Right Through Carry ..................................................................................6-42
Subtract With Carry .............................................................................................6-43
Set Carry Flag.....................................................................................................6-44
Shift Right Arithmetic...........................................................................................6-45
Stop Operation....................................................................................................6-46
Subtract .............................................................................................................6-47
Test Complement Under Mask..............................................................................6-48
Test Under Mask.................................................................................................6-49
Logical Exclusive OR...........................................................................................6-50
S3C94A5/F94A5 MICROCONTROLLER
xxi
S3C94A5/F94A5
1
PRODUCT OVERVIEW
PRODUCT OVERVIEW
SAM88RCRI PRODUCT FAMILY
Samsung's SAM88RCRI family of 8-bit single-chip CMOS microcontrollers offer fast and efficient CPU, a wide range
of integrated peripherals, and supports Flash device.
A dual address/data bus architecture and bit- or nibble-configurable I/O ports provide a flexible programming
environment for applications with varied memory and I/O requirements. Timer/counters with selectable operating
modes are included to support real-time operations.
S3C94A5/F94A5 MICROCONTROLLER
The S3C94A5 can be used for dedicated control functions in a variety of applications, and is especially designed for
application with printer or etc.
The S3C94A5/F94A5 single-chip 8-bit microcontroller is fabricated using an advanced CMOS process. It is built
around the powerful SAM88RCRI CPU core.
Stop and Idle power-down modes were implemented to reduce power consumption. To increase on-chip register
space, the size of the internal register file was logically expanded. The S3C94A5/F94A5 has 16K-byte of program
ROM, and 368-byte of RAM (including 16-byte of working register).
Using the SAM88RCRI design approach, the following peripherals were integrated with the SAM88RCRI core:
— 5 configurable I/O ports including ports
— 15-bit programmable pins for external interrupts
— One 8-bit basic timer for oscillation stabilization and watch-dog functions
— Two 16-bit timer/counters and one 8-bit timer/counter with selectable operating modes
— Watch timer for real time
— 16 channel A/D converter
— 8-bit serial I/O interface
FLASH
The S3F94A5 microcontroller is available in Flash version. S3C94A5 microcontroller has an on-chip 16K-byte
masked ROM. The S3F94A5 is comparable to S3C94A5, both in function and in pin configuration.
1-1
PRODUCT OVERVIEW
S3C94A5/F94A5
FEATURES
CPU
8-bit Serial I/O Interface
•
•
8-bit transmit/receive mode
•
8-bit receive mode
•
LSB-first or MSB-first transmission selectable
•
Internal or external clock source
SAM88RCRI CPU core
Memory
•
•
16k × 8 bits program memory (ROM)
368 × 8 bits data memory (RAM)
Instruction Set
•
41 instructions
•
Idle and Stop instructions added for power-down
modes
A/D Converter
•
10-bit converter resolution
•
50us conversion speed at 1MHz fADC clock
•
16-channel
34 I/O Pins
Two Power-Down Modes
•
•
•
High sink current (20mA at 3.3V)
Idle mode: only CPU clock stops
Stop mode: system clock and CPU clock stop
Interrupts
•
•
23 interrupt source and 1 vector
One interrupt level
8-Bit Basic Timer
•
•
Watchdog timer function
4 kinds of clock source
Oscillation Sources
•
Crystal, ceramic, or RC for main clock
(Internal or external RC oscillation)
•
•
System clock frequency: 0.4 MHz – 12 MHz
CPU clock output
Instruction Execution Times
16-Bit Timer/Counter 0
•
External event counter
•
PWM and capture function
•
333nS at 12 MHz fx (minimum)
Operating Voltage Range
•
2.0 V to 5.5 V at 4.2 MHz
16-Bit Timer/Counter 1
•
2.7 V to 5.5 V at 8 MHz
•
Programmable 16-bit interval timer
•
3.0 V to 5.5 V at 12 MHz
•
PWM and capture function
Operating Temperature Range
8-Bit Timer/Counter 2
•
Programmable 8-bit interval timer
•
PWM and capture function
•
–25 °C to +85 °C
Package Type
•
44-pin QFP, 42-pin SDIP
Watch Timer
•
•
1-2
Interval time: 3.91mS, 0.25S, 0.5S, and 1S
at 4.19 MHz
0.5/1/2/4 kHz Selectable buzzer output
Smart Option
•
Oscillator type selectable by ROM option
(ROM address 3FH)
S3C94A5/F94A5
PRODUCT OVERVIEW
T0PWM/T0OUT/P3.3
T0CAP/P3.4
T0CLK/P3.5
16-Bit
Timer/
Counter0
T1OUT/T1PWM/P4.0
T1CAP/P4.2
16-Bit
Timer/
Counter1
T2OUT/T2PWM/P4.1
T2CAP/P4.3
8-Bit
Timer/
Counter2
P1.0/INT
P1.1/INT
P1.2/INT
P1.3/INT
P1.4/INT
P1.5/INT
P1.6/INT
P2.0 - P2.5/
AD0 - AD5
P3.0/AD6/CLO/INT
P3.1/AD7/BUZ/INT
P3.2/AD8/INT
P3.3/AD9/T0OUT/T0PWM/INT
P3.4/AD10/T0CAP/INT
P3.5/AD11/T0CLK/INT
TEST
VDD1
VDD2
VSS1
VSS2
XOUT
XIN
CLO
INT
nRESET
BLOCK DIAGRAM
Watch Dog
Timer
Basic Timer
Port I/O and Interrupt
Control
SAM88RCRI CPU
Watch Timer
BUZ/P3.1
SIO
SO/P4.4
SI/P4.5
SCK/P4.6
A/D
Converter
AD0 - AD15
AVREF
AVSS
I/O Port 4
P4.0/AD12/T1OUT/T1PWM
P4.1/AD13/T2OUT/T2PWM
P4.2/T1CAP
P4.3/T2CAP
P4.4/SO
P4.5/SI
P4.6/SCK
P4.7/AD14/INT
I/O Port 1
I/O Port 2
16-Kbyte
ROM
368-Byte
Register
File
I/O Port 5
I/O Port 3
P5.0/AD15/INT
P5.1
P5.2
P5.3
P5.4
P5.5
P5.6
Figure 1-1. Block Diagram
1-3
PRODUCT OVERVIEW
S3C94A5/F94A5
44
43
42
41
40
39
38
37
36
35
34
P1.0/INT
VDD1
XIN
XOUT
VSS1
nRESET
TEST
P5.6
P5.5
P5.4
P5.3
PIN ASSIGNMENTS
1
2
3
4
5
6
7
8
9
10
11
S3C94A5
S3F94A5
(44-QFP-1010B)
33
32
31
30
29
28
27
26
25
24
23
P5.2
P5.1
P5.0/AD15/INT
P4.7/AD14/INT
P4.6/SCK
P4.5/SI
P4.4/SO
P4.3/T2CAP
P4.2/T1CAP
P4.1/AD13/T2OUT/T2PWM
P4.0/AD12/T1OUT/T1PWM
P2.5/AD5
AVREF
AVSS
P3.0/AD6/CLO/INT
P3.1/AD7/BUZ/INT
P3.2/AD8/INT
P3.3/AD9/T0OUT/T0PWM/INT
P3.4/AD10/T0CAP/INT
P3.5/AD11/T0CLK/INT
VDD2
VSS2
12
13
14
15
16
17
18
19
20
21
22
P1.1/INT
P1.2/INT
P1.3/INT
P1.4/INT
P1.5/INT
P1.6/INT
P2.0/AD0
P2.1/AD1
P2.2/AD2
P2.3/AD3
P2.4/AD4
Figure 1-2. S3C94A5/F94A5 Pin Assignments (44-QFP-1010B)
1-4
S3C94A5/F94A5
PRODUCT OVERVIEW
S3C94A5
S3F94A5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
(42-SDIP-600)
P1.6/INT
P2.0/AD0
P2.1/AD1
P2.2/AD2
P2.3/AD3
P2.4/AD4
P2.5/AD5
AVREF
AVSS
P3.0/AD6/CLO/INT
P3.1/AD7/BUZ/INT
P3.2/AD8/INT
P3.3/AD9/T0OUT/T0PWM/INT
P3.4/AD10/T0CAP/INT
P3.5/AD11/T0CLK/INT
P4.0/AD12/T1OUT/T1PWM
P4.1/AD13/T2OUT/T2PWM
P4.2/T1CAP
P4.3/T2CAP
P4.4/SO
P4.5/SI
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
P1.5/INT
P1.4/INT
P1.3/INT
P1.2/INT
P1.1/INT
P1.0/INT
VDD1
XIN
XOUT
VSS1
nRESET
TEST
P5.6
P5.5
P5.4
P5.3
P5.2
P5.1
P5.0/AD15/INT
P4.7/AD14/INT
P4.6/SCK
Figure 1-3. S3C94A5/F94A5 Pin Assignments (42-SDIP-600)
1-5
PRODUCT OVERVIEW
S3C94A5/F94A5
PIN DESCRIPTIONS
Table 1-1. Pin Descriptions
Pin Names
Pin
Type
Pin Description
Circuit
Number
Pin
Numbers
Share
Pins
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
I/O
1-bit programmable I/O port.
Schmitt trigger input or push-pull, opendrain output and software assignable pullups.
E-4
44(37)
1(38)
2(39)
3(40)
4(41)
5(42)
6(1)
INT
INT
INT
INT
INT
INT
INT
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
I/O
1-bit programmable I/O port.
Input or push-pull, open-drain output and
software assignable pull-ups.
F-16
7(2)
8(3)
9(4)
10(5)
11(6)
12(7)
AD0
AD1
AD2
AD3
AD4
AD5
P3.0
P3.1
P3.2
P3.3
I/O
1-bit programmable I/O port.
Schmitt trigger input or push-pull, opendrain output and software assignable pullups.
F-16A
15(10)
16(11)
17(12)
18(13)
AD6/CLO/INT
AD7/BUZ/INT
AD8/INT
AD9/T0OUT/
T0PWM/INT
AD10/T0CAP/INT
AD11/T0CLK/INT
P3.4
P3.5
19(14)
20(15)
I/O
P4.0
P4.1
1-bit programmable I/O port.
Schmitt trigger input or push-pull, opendrain output and software assignable pullups.
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7
P5.0
P5.1–P5.6
NOTE:
1-6
I/O
1-bit programmable I/O port.
Input or push-pull, open-drain output and
software assignable pull-ups.
Parentheses indicate pin number for 42-SDIP-600 package.
F-16A
23(16)
F-16A
24(17)
E-4
E-4
E-4
E-4
E-4
F-16A
25(18)
26(19)
27(20)
28(21)
29(22)
30(23)
AD12/T1OUT/
T1PWM
AD13/T2OUT/
T2PWM
T1CAP
T2CAP
SO
SI
SCK
AD14/INT
F-16
E-2
31(24)
32-37(25-30)
AD15/INT
–
S3C94A5/F94A5
PRODUCT OVERVIEW
Table 1-1. Pin Descriptions (Continued)
Pin Names
Pin
Type
Pin Description
Circuit
Number
Pin
Numbers
Share
Pins
VDD1, VSS1
VDD2, VSS2
–
Power input pins for internal power block
–
43,40(36,33)
21,22(-)
–
XOUT, XIN
–
Oscillator pins for system clock
–
41,42(34,35)
–
TEST
–
Chip test input pin
Hold GND when the device is operating
–
38(31)
–
nRESET
I
nRESET signal input pin. Schmitt trigger
input with internal pull-up resistor.
B
39(32)
–
E-4
P1.0-P1.6
F-16A
F-16A
F-16
44,1-6
(37-42,1)
15-20(10-15)
30(23)
31(24)
INT
I/O
External interrupts input.
P3.0-P3.5
P4.7
P5.0
T0CLK
I/O
Timer 0 external clock input
F-16A
20(15)
P3.5
T0CAP
I/O
Timer 0 capture input
F-16A
19(14)
P3.4
T0OUT
I/O
Timer 0 clock output
F-16A
18(13)
P3.3
T0PWM
I/O
Timer 0 PWM output
F-16A
18(13)
P3.3
T1CAP
I/O
Timer 1 capture input
E-4
25(18)
P4.2
T1OUT
I/O
Timer 1 clock output
F-16A
23(16)
P4.0
T1PWM
I/O
Timer 1 PWM input
F-16A
23(16)
P4.0
T2CAP
I/O
Timer 2 capture input
E-4
26(19)
P4.3
T2OUT
I/O
Timer 2 clock output
F-16A
24(17)
P4.1
T2PWM
I/O
Timer 2 PWM output
F-16A
24(17)
P4.1
AD0–AD5
AD6–AD11
AD12,13,14
I/O
Analog input pins for A/D converts module
F-16
F-16A
F-16A
F-16
7-12(2-7)
15-20(10-15)
23,24,30
(16,17,23)
31(24)
P2.0-P2.5
P3.0-P3.5
P4.0,P4.1,
P4.7
P5.0
AD15
AVREF
–
A/D converter reference voltage
–
13(8)
–
AVSS
–
A/D converter ground
–
14(9)
–
BUZ
I/O
Buzzer signal output
F-16A
16(11)
P3.1
CLO
I/O
CPU clock output
F-16A
15(10)
P3.0
SCK
SI
SO
I/O
Serial clock, serial data input, serial data
output
E-4
29(22)
28(21)
27(20)
P4.6
P4.5
P4.4
NOTE:
Parentheses indicate pin number for 42-SDIP-600 package.
1-7
PRODUCT OVERVIEW
S3C94A5/F94A5
PIN CIRCUIT DIAGRAMS
VDD
Pull-Up
Resistor
nRESET
Noise Filter
Figure 1-4. Pin Circuit Type B (nRESET)
VDD
Open-Drain
Data
Output
Output
Disable
Figure 1-5. Pin Circuit Type E
1-8
S3C94A5/F94A5
PRODUCT OVERVIEW
VDD
Pull-up
Resistor
VDD
Resistor
Enable
Open-Drain
Data
I/O
Output
Disable
Figure 1-6. Pin Circuit Type E-2 (P5.1–P5.6)
VDD
VDD
Pull-up
Resistor
Pull-up
Enable
Open-Drain
Data
I/O
Output
Disable
Figure 1-7. Pin Circuit Type E-4 (P1, P4.2–P4.6)
1-9
PRODUCT OVERVIEW
S3C94A5/F94A5
VDD
Pull-up
Resistor
Pull-up Enable
Open-Drain EN
Data
Output Disable
Circuit
Type E
I/O
ADEN
AD Select
Data
To ADC
Figure 1-8. Pin Circuit Type F-16 (P2, P5.0)
VDD
Pull-up
Resistor
Pull-up Enable
Open-Drain EN
Data
Output Disable
Circuit
Type E
I/O
ADEN
AD Select
Data
To ADC
Figure 1-9. Pin Circuit Type F-16A (P3, P4.0, P4.1, P4.7)
1-10
S3C94A5/F94A5
2
ADDRESS SPACES
ADDRESS SPACES
OVERVIEW
The S3C94A5/F94A5 microcontroller has two kinds of address space:
— Program memory (ROM)
— Internal register file
A 16-bit address bus supports program memory operations. Special instructions and related internal logic determine
when the 16-bit bus carries addresses for program memory. A separate 8-bit register bus carries addresses and data
between the CPU and the internal register file.
The S3C94A5 has 16K bytes of mask-programmable program memory on-chip. The S3C94A5/F94A5 microcontroller
has 368 bytes general-purpose registers in its internal register file 64 bytes in the register file are mapped for system
and peripheral control functions.
2-1
ADDRESS SPACES
S3C94A5/F94A5
PROGRAM MEMORY (ROM)
Program memory (ROM) stores program code or table data. The S3C94A5 has 16K bytes of mask-programable
program memory. The program memory address range is therefore 0H-3FFFH. The first 2 bytes of the ROM (0000H–
0001H) are an interrupt vector address. The program reset address in the ROM is 0100H.
(Decimal)
16,386
(Hex)
3FFFH
16K bytes
Internal
Program
Memory
Area
256
Program Start
2
1
0
0100H
0002H
Interrupt
Vector
0001H
0000H
Figure 2-1. S3C94A5/F94A5 Program Memory Address Space
2-2
S3C94A5/F94A5
ADDRESS SPACES
SMART OPTION
Smart option is the ROM option for starting condition of the chip. The ROM addresses used by smart option are from
003CH to 003FH. The S3C94A5 only use 003FH and ROM address 003CH, 003DH, 003EH is not used.
For example, if you program as below:
ORG
003FH
DB
01H
; Select internal RC oscillation
If you don't program any values in these option areas, then the default value is "1".
In these cases, the address 003CH, 003DH, 003EH would be the value of "FFH".
2-3
ADDRESS SPACES
S3C94A5/F94A5
ROM Address: 003CH
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
.1
.0
LSB
.1
.0
LSB
.1
.0
LSB
Not Used
ROM Address: 003DH
MSB
.7
.6
.5
.4
.3
.2
Not Used
ROM Address: 003EH
MSB
.7
.6
.5
.4
.3
.2
Not Used
ROM Address: 003FH
MSB
.7
.6
.5
Not Used
.4
.3
.2
Oscillator selection bits:
000 = External crystal, ceramic, External RC oscillation mode 1
001 = Internal RC oscillation
100 = fERC/1 (External RC oscillation mode 2)
101 = fERC/2 (External RC oscillation mode 2)
110 = fERC/4 (External RC oscillation mode 2)
111 = fERC/8 (External RC oscillation mode 2)
NOTE:
The value of unused bits of 3FH is don't care.
Figure 2-2. Smart Option
2-4
S3C94A5/F94A5
ADDRESS SPACES
REGISTER ARCHITECTURE
The upper 80 bytes of the S3C94A5/F94A5's internal register file are addressed as working registers, system control
registers and peripheral control registers. The lower 176 bytes of internal register file (00H–AFH) is called the general
purpose register space.
For many SAM88RCRI microcontrollers, the addressable area of the internal register file is further expanded by the
additional of one or more register pages at general purpose register space (00H–BFH). This register file expansion is
implemented by page 1 in the S3C94A5/F94A5.
FFH
Peripheral Control
Registers
80 Bytes of
Common Area
E0H
DFH
System Control
Registers
D0H
CFH
Working Registers
C0H
BFH
Peripheral Control
Registers
B0H
AFH
AFH
General Purpose
Register File
and Stack Area
176 Bytes
General Purpose
Register File
176 Bytes
~
00H
00H
(Page 0)
(Page 1)
Figure 2-3. Internal Register File Organization
2-5
ADDRESS SPACES
S3C94A5/F94A5
COMMON WORKING REGISTER AREA (C0H–CFH)
The SAM88RCRI register architecture provides an efficient method of working register addressing that takes full
advantage of shorter instruction formats to reduce execution time.
This16-byte address range is called common area. That is, locations in this area can be used as working registers
by operations that address any location on any page in the register file. Typically, these working registers serve as
temporary buffers for data operations between different pages.
The Register (R) addressing mode can be used to access this area
Registers are addressed either as a single 8-bit register or as a paired 16-bit register. In 16-bit register pairs, the
address of the first 8-bit register is always an even number and the address of the next register is an odd number.
The most significant byte of the 16-bit data is always stored in the even-numbered register; the least significant byte
is always stored in the next (+ 1) odd-numbered register.
MSB
LSB
Rn
Rn + 1
n = Even address
Figure 2-4. 16-Bit Register Pairs
F
PROGRAMMING TIP — Addressing the Common Working Register Area
As the following examples show, you should access working registers in the common area, locations C0H–CFH,
using working register addressing mode only.
Examples:
1.
LD
0C2H,40H
; Invalid addressing mode!
Use working register addressing instead:
2.
LD
R2,40H
; R2 (C2H) ← the value in location 40H
ADD
0C3H,#45H
; Invalid addressing mode!
Use working register addressing instead:
ADD
2-6
R3,#45H
; R3 (C3H) ← R3 + 45H
S3C94A5/F94A5
ADDRESS SPACES
SYSTEM STACK
S3C9-series microcontrollers use the system stack for subroutine calls and returns and to store data. The PUSH
and POP instructions are used to control system stack operations. The S3C94A5/F94A5 architecture supports
stack operations in the internal register file.
STACK OPERATIONS
Return addresses for procedure calls and interrupts and data are stored on the stack. The contents of the PC are
saved to stack by a CALL instruction and restored by the RET instruction. When an interrupt occurs, the contents of
the PC and the FLAGS register are pushed to the stack. The IRET instruction then pops these values back to their
original locations. The stack address is always decremented before a push operation and incremented after a pop
operation. The stack pointer (SP) always points to the stack frame stored on the top of the stack, as shown in Figure
2-5.
High Address
PCL
PCL
Top of
stack
PCH
PCH
Top of
stack
Stack contents
after a call
instruction
Low Address
Flags
Stack contents
after an
interrupt
Figure 2-5. Stack Operations
STACK POINTER (SP)
Register location D9H contains the 8-bit stack pointer (SP) that is used for system stack operations. After a reset,
the SP value is undetermined.
Because only internal memory space is implemented in the S3C94A5/F94A5, the SP must be initialized to an 8-bit
value in the range 00H–B7H.
NOTE
In case a Stack Pointer is initialized to 00H, it is decreased to FFH when stack operation starts. This means
that a Stack Pointer access invalid stack area.
2-7
ADDRESS SPACES
S3C94A5/F94A5
F PROGRAMMING TIP — Standard Stack Operations Using PUSH and POP
The following example shows you how to perform stack operations in the internal register file using PUSH and POP
instructions:
LD
SP,#0B8H
; SP ← B8H (Normally, the SP is set to 0B8H by the
; initialization routine)
SYM
WTCON
20H
R3
;
;
;
;
Stack address 0B7H
Stack address 0B6H
Stack address 0B5H
Stack address 0B4H
R3
20H
WTCON
SYM
;
;
;
;
R3 ← Stack address 0B4H
20H ← Stack address 0B5H
WTCON ← Stack address 0B6H
SYM ← Stack address 0B7H
•
•
•
PUSH
PUSH
PUSH
PUSH
←
←
←
←
SYM
WTCON
20H
R3
•
•
•
POP
POP
POP
POP
2-8
S3C94A5/F94A5
3
ADDRESSING MODES
ADDRESSING MODES
OVERVIEW
Instructions that are stored in program memory are fetched for execution using the program counter. Instructions
indicate the operation to be performed and the data to be operated on. Addressing mode is the method used to
determine the location of the data operand. The operands specified in SAM88RCRI instructions may be condition
codes, immediate data, or a location in the register file, program memory, or data memory.
The SAM88RCRI instruction set supports six explicit addressing modes. Not all of these addressing modes are
available for each instruction. The addressing modes and their symbols are as follows:
— Register (R)
— Indirect Register (IR)
— Indexed (X)
— Direct Address (DA)
— Relative Address (RA)
— Immediate (IM)
3-1
ADDRESSING MODES
S3C94A5/F94A5
REGISTER ADDRESSING MODE (R)
In Register addressing mode, the operand is the content of a specified register (see Figure 3-1). Working register
addressing differs from Register addressing because it uses a 16-byte working register space in the register file and
a 4-bit register within that space (see Figure 3-2).
Program Memory
8-bit Register
File Address
dst
OPCODE
One-Operand
Instruction
(Example)
Register File
OPERAND
Point to One
Rigister in Register
File
Value used in
Instruction Execution
Sample Instruction:
DEC
CNTR
;
Where CNTR is the label of an 8-bit register address
Figure 3-1. Register Addressing
Register File
CFH
.
.
.
.
Program Memory
4-Bit
Working Register
dst
src
OPCODE
Two-Operand
Instruction
(Example)
4 LSBs
OPERAND
Point to the
Woking Register
(1 of 16)
Sample Instruction:
ADD
R1, R2
;
Where R1 = C1H and R2 = C2H
Figure 3-2. Working Register Addressing
3-2
C0H
S3C94A5/F94A5
ADDRESSING MODES
INDIRECT REGISTER ADDRESSING MODE (IR)
In Indirect Register (IR) addressing mode, the content of the specified register or register pair is the address of the
operand. Depending on the instruction used, the actual address may point to a register in the register file, to
program memory (ROM), or to an external memory space (see Figures 3-3 through 3-6).
You can use any 8-bit register to indirectly address another register. Any 16-bit register pair can be used to
indirectly address another memory location.
Program Memory
8-Bit Register
File Address
dst
OPCODE
One-Operand
Instruction
(Example)
Register File
ADDRESS
Point to One
Rigister in Register
File
Address of Operand
used by Instruction
Value used in
Instruction Execution
OPERAND
Sample Instruction:
RL
@SHIFT
;
Where SHIFT is the label of an 8-Bit register address
Figure 3-3. Indirect Register Addressing to Register File
3-3
ADDRESSING MODES
S3C94A5/F94A5
INDIRECT REGISTER ADDRESSING MODE (Continued)
Register File
Program Memory
Example
Instruction
References
Program
Memory
dst
OPCODE
REGISTER
PAIR
Points to
Rigister Pair
Program Memory
Sample Instructions:
CALL
JP
@RR2
@RR2
Value used in
Instruction
OPERAND
Figure 3-4. Indirect Register Addressing to Program Memory
3-4
16-Bit
Address
Points to
Program
Memory
S3C94A5/F94A5
ADDRESSING MODES
INDIRECT REGISTER ADDRESSING MODE (Continued)
Register File
CFH
Program Memory
4-Bit
Working
Register
Address
dst
src
OPCODE
4 LSBs
.
.
.
.
OPERAND
Point to the
Woking Register
(1 of 16)
C0H
Sample Instruction:
OR
R6, @R2
Value used in
Instruction
OPERAND
Figure 3-5. Indirect Working Register Addressing to Register File
3-5
ADDRESSING MODES
S3C94A5/F94A5
INDIRECT REGISTER ADDRESSING MODE (Concluded)
Register File
CFH
.
.
.
.
Program Memory
4-Bit Working
Register Address
Example Instruction
References either
Program Memory or
Data Memory
dst
src
OPCODE
Next 3 Bits Point
to Working
Register Pair
(1 of 8)
LSB Selects
Value used in
Instruction
Register
Pair
C0H
Program Memory
or
Data Memory
16-Bit
address
points to
program
memory
or data
memory
OPERAND
Sample Instructions:
LCD
LDE
LDE
R5,@RR6
R3,@RR14
@RR4, R8
; Program memory access
; External data memory access
; External data memory access
Figure 3-6. Indirect Working Register Addressing to Program or Data Memory
3-6
S3C94A5/F94A5
ADDRESSING MODES
INDEXED ADDRESSING MODE (X)
Indexed (X) addressing mode adds an offset value to a base address during instruction execution in order to
calculate the effective operand address (see Figure 3-7). You can use Indexed addressing mode to access locations
in the internal register file or in external memory.
In short offset Indexed addressing mode, the 8-bit displacement is treated as a signed integer in the range of
–128 to +127. This applies to external memory accesses only (see Figure 3-8).
For register file addressing, an 8-bit base address provi ded by the instruction is added to an 8-bit offset contained in
a working register. For external memory accesses, the base address is stored in the working register pair
designated in the instruction. The 8-bit or 16-bit offset given in the instruction is then added to the base address (see
Figure 3-9).
The only instruction that supports Indexed addressing mode for the internal register file is the Load instruction (LD).
The LDC and LDE instructions support Indexed addressing mode for internal program memory, external program
memory, and for external data memory, when implemented.
Register File
~
~
Value used in
Instruction
OPERAND
+
Program Memory
Two-Operand
Instruction
Example
Base Address
dst
src
OPCODE
4 LSBs
Point to One of the
Woking Register
(1 of 16)
~
~
INDEX
Sample Instruction:
LD
R0, #BASE[R1]
;
Where BASE is an 8-bit immediate value
Figure 3-7. Indexed Addressing to Register File
3-7
ADDRESSING MODES
S3C94A5/F94A5
INDEXED ADDRESSING MODE (Continued)
Program Memory
4-Bit Working
Register Address
XS (OFFSET)
dst
src
OPCODE
Register File
NEXT 3 Bits
Point to Working
Register Pair
(1 of 8)
Register
Pair
16-Bit
address
added to
offset
LSB Selects
+
8-Bits
16-Bits
Program Memory
or
Data Memory
16-Bits
OPERAND
Value used in
Instruction
Sample Instructions:
LDC
R4, #04H[RR2]
LDE
R4,#04H[RR2]
; The values in the program address (RR2 + #04H)
are loaded into register R4.
; Identical operation to LDC example, except that
external program memory is accessed.
Figure 3-8. Indexed Addressing to Program or Data Memory with Short Offset
3-8
S3C94A5/F94A5
ADDRESSING MODES
INDEXED ADDRESSING MODE (Concluded)
Program Memory
4-Bit Working
Register Address
XL H (OFFSET)
XL L (OFFSET)
dst
src
OPCODE
Register File
NEXT 3 Bits
Register
Pair
Point to Working
Register Pair
(1 of 8)
16-Bit
address
added to
offset
LSB Selects
+
8-Bits
16-Bits
Program Memory
or
Data Memory
16-Bits
OPERAND
Value used in
Instruction
Sample Instructions:
LDC
R4, #1000H[RR2]
#1000H)
LDE
R4, #1000H[RR2]
; The values in the program address (RR2 +
are loaded into register R4.
; Identical operation to LDC example, except that
external program memory is accessed.
Figure 3-9. Indexed Addressing to Program or Data Memory with Long Offset
3-9
ADDRESSING MODES
S3C94A5/F94A5
DIRECT ADDRESS MODE (DA)
In Direct Address (DA) mode, the instruction provides the operand's 16-bit memory address. Jump (JP) and Call
(CALL) instructions use this addressing mode to specify the 16-bit destination address that is loaded into the PC
whenever a JP or CALL instruction is executed.
The LDC and LDE instructions can use Direct Address mode to specify the source or destination address for Load
operations to program memory (LDC) or to external data memory (LDE), if implemented.
Program or
Data Memory
Program Memory
Memory
Address
Used
Upper Address Byte
Lower Address Byte
dst/src
"0" or "1"
OPCODE
LSB Selects Program
Memory or Data Memory:
"0" = Program Memory
"1" = Data Memory
Sample Instructions:
LDC
R5,1234H
LDE
R5,1234H
;
The values in the program address (1234H)
are loaded into register R5.
; Identical operation to LDC example, except that
external program memory is accessed.
Figure 3-10. Direct Addressing for Load Instructions
3-10
S3C94A5/F94A5
ADDRESSING MODES
DIRECT ADDRESS MODE (Continued)
Program Memory
Next OPCODE
Program
Memory
Address
Used
Lower Address Byte
Upper Address Byte
OPCODE
Sample Instructions:
JP
CALL
C,JOB1
DISPLAY
;
;
Where JOB1 is a 16-bit immediate address
Where DISPLAY is a 16-bit immediate address
Figure 3-11. Direct Addressing for Call and Jump Instructions
3-11
ADDRESSING MODES
S3C94A5/F94A5
RELATIVE ADDRESS MODE (RA)
In Relative Address (RA) mode, a two's-complement signed displacement between – 128 and + 127 is specified in
the instruction. The displacement value is then added to the current PC value. The result is the address of the next
instruction to be executed. Before this addition occurs, the PC contains the address of the instruction immediately
following the current instruction.
The instructions that support RA addressing is JR.
Program Memory
Next OPCODE
Program Memory
Address Used
Current Instruction
Current
PC Value
Displacement
OPCODE
+
Signed
Displacement Value
Sample Instructions:
JR
ULT,$ + OFFSET
;
Where OFFSET is a value in the range + 127 to - 128
Figure 3-12. Relative Addressing
IMMEDIATE MODE (IM)
In Immediate (IM) addressing mode, the operand value used in the instruction is the value supplied in the operand
field itself. Immediate addressing mode is useful for loading constant values into registers.
Program Memory
OPERAND
OPCODE
(The Operand value is in the instruction)
Sample Instruction:
LD
R0,#0AAH
Figure 3-13. Immediate Addressing
3-12
S3C94A5/F94A5
4
CONTROL REGISTERS
CONTROL REGISTERS
OVERVIEW
In this section, detailed descriptions of the S3C94A5/F94A5 control registers are presented in an easy-to-read
format. These descriptions will help familiarize you with the mapped locations in the register file. You can also use
them as a quick-reference source when writing application programs.
System and peripheral registers are summarized in Table 4-1. Figure 4-1 illustrates the important features of the
standard register description format.
Control register descriptions are arranged in alphabetical order according to register mnemonic. More information
about control registers is presented in the context of the various peripheral hardware descriptions in Part II of this
manual.
4-1
CONTROL REGISTERS
S3C94A5/F94A5
Table 4-1. System and Peripheral Control Registers
Register Name
Mnemonic
Address
Decimal
R/W
Hex
Locations B0H — B3H are not mapped
Timer 0 control register
T0CON
196
B4H
R/W
Timer 0 data register (high byte)
T0DATAH
197
B5H
R/W
Timer 0 data register (low byte)
T0DATAL
198
B6H
R/W
Timer 0 counter (high byte)
T0CNTH
199
B7H
R
Timer 0 counter (low byte)
T0CNTL
200
B8H
R
Timer 1 control resistor
T1CON
201
B9H
R/W
Timer 1 data register (high byte)
T1DATAH
202
BAH
R/W
Timer 1 data register (low byte)
T1DATAL
203
BBH
R/W
Timer 1 counter (high byte)
T1CNTH
204
BCH
R
Timer 1 counter (low byte)
T1CNTL
205
BDH
R
Timer 2 control register
T2CON
206
BEH
R/W
Timer 2 data register
T2DATA
207
BFH
R/W
T2CNT
208
D0H
R
ADCON
209
D1H
R/W
A/D converter data register (high byte)
ADDATAH
210
D2H
R
A/D converter data register (low byte)
ADDATAL
211
D3H
R
System clock control register
CLKCON
212
D4H
R/W
FLAGS
213
D5H
R/W
Interrupt pending register 1
INTPND1
214
D6H
R/W
Interrupt pending register 2
INTPND2
215
D7H
R/W
Interrupt pending register 3
INTPND3
216
D8H
R/W
SP
217
D9H
R/W
WTCON
218
DAH
R/W
Timer 2 counter
A/D converter control register
System flags register
Stack pointer
Watch timer control register
Location DBH is not mapped
Basic timer control register
BTCON
220
DCH
R/W
Basic timer counter
BTCNT
221
DDH
R
Location DEH is not mapped
System mode register
SYM
223
DFH
R/W
STOP control register
STPCON
224
E0H
R/W
SIO control register
SIOCON
225
E1H
R/W
SIO data register
SIODATA
226
E2H
R/W
SIOPS
227
E3H
R/W
SIO prescaler register
4-2
S3C94A5/F94A5
CONTROL REGISTERS
Table 4-1. System and Peripheral Control Registers (Continued)
Register Name
Mnemonic
Address
R/W
Decimal
Hex
Port 1 data register
P1
228
E4H
R/W
Port 2 data register
P2
229
E5H
R/W
Port 3 data register
P3
230
E6H
R/W
Port 4 data register
P4
231
E7H
R/W
Port 5 data register
P5
232
E8H
R/W
Location E9H is not mapped
Port 1 control register (high byte)
P1CONH
234
EAH
R/W
Port 1 control register (low byte)
P1CONL
235
EBH
R/W
P1INT
236
ECH
R/W
Port 1 interrupt edge selection register
(high byte)
P1EDGEH
237
EDH
R/W
Port 1 interrupt edge selection register
(low byte)
P1EDGEL
238
EEH
R/W
Port 2 control register (high byte)
P2CONH
239
EFH
R/W
Port 2 control register (low byte)
P2CONL
240
F0H
R/W
P2PUR
241
F1H
R/W
Port 3 control register (high byte)
P3CONH
242
F2H
R/W
Port 3 control register (low byte)
P3CONL
243
F3H
R/W
P3PUR
244
F4H
R/W
P3INT
245
F5H
R/W
Port 3 interrupt edge selection register
(high byte)
P3EDGEH
246
F6H
R/W
Port 3 interrupt edge selection register
(low byte)
P3EDGEL
247
F7H
R/W
Port 4 control register (high byte)
P4CONH
248
F8H
R/W
Port 4 control register (middle byte)
P4CONM
249
F9H
R/W
Port 4 control register (low byte)
P4CONL
250
FAH
R/W
Port 4 and 5 interrupt control register
P4n5INT
251
FBH
R/W
Port 4 pull-up control register
P4PUR
252
FCH
R/W
Port 5 control register (high byte)
P5CONH
253
FDH
R/W
Port 5 control register (low byte)
P5CONL
254
FEH
R/W
Port 1 interrupt control register
Port 2 pull-up control register
Port 3 pull-up control register
Port 3 interrupt control register
Location FFH is not mapped
4-3
CONTROL REGISTERS
S3C94A5/F94A5
Bit number(s) that is/are appended to the
register name for bit addressing
Name of individual
Register
bit or bit function
Full Register name
mnemonic
Register address
(hexadecimal)
D5H
FLAGS - System Flags Register
Bit Identifier
RESET Value
Read/Write
.7
.7
.6
.5
.4
.3
.2
.1
.0
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
0
R/W
0
R/W
Carry Flag (C)
.6
0
Operation dose not generate a carry or borrow condition
1
Operation generates carry-out or borrow into high-order bit7
Zero Flag
.5
0
Operation result is a non-zero value
1
Operation result is zero
Sign Flag
0
Operation generates positive number (MSB = "0")
1
Operation generates negative number (MSB = "1")
R = Read-only
W = Write-only
R/W = Read/write
' - ' = Not used
Addressing mode or
modes you can use to
modify register values
Description of the
effect of specific
bit settings
RESET value notation:
'-' = Not used
'x' = Undetermind value
'0' = Logic zero
'1' = Logic one
Figure 4-1. Register Description Format
4-4
Bit number:
MSB = Bit 7
LSB = Bit 0
S3C94A5/F94A5
CONTROL REGISTERS
ADCON — A/D Converter Control Register
Bit Identifier
RESET Value
Read/Write
.7
0
R/W
.6
0
R/W
.5
0
R/W
D1H
.4
0
R/W
.3
0
R
.2
0
R/W
.1
0
R/W
.7–.4
A/D Input Pin Selection Bits
0
0
0
0 AD0 (P2.0)
0
0
0
1 AD1 (P2.1)
0
0
1
0 AD2 (P2.2)
0
0
1
1 AD3 (P2.3)
0
1
0
0 AD4 (P2.4)
0
1
0
1 AD5 (P2.5)
0
1
1
0 AD6 (P3.0)
0
1
1
1 AD7 (P3.1)
1
0
0
0 AD8 (P3.2)
1
0
0
1 AD9 (P3.3)
1
0
1
0 AD10 (P3.4)
1
0
1
1 AD11 (P3.5)
1
1
0
0 AD12 (P4.0)
1
1
0
1 AD13 (P4.1)
1
1
1
0 AD14 (P4.7)
1
1
1
1 AD15 (P5.0)
.3
End of Conversion Bit (Read-only)
0 Conversion not complete
1 Conversion complete
.2–.1
Clock Source Selection Bits
0
0 fxx/16
0
1 fxx/8
1
0 fxx/4
1
1 fxx
.0
Start or Enable Bit
0 Disable operation
1 Start operation (automatically disable operation after conversion complete)
.0
0
R/W
4-5
CONTROL REGISTERS
S3C94A5/F94A5
BTCON — Basic Timer Control Register
DCH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.4
Watchdog Timer Enable Bits
1
.3–.2
.1
.0
0
1
0
Disable watchdog function
Any other value
Enable watchdog function
Basic Timer Input Clock Selection Bits
0
0
fxx/4096
0
1
fxx/1024
1
0
fxx/128
1
1
fxx/16
Basic Timer Counter Clear Bit (1)
0
No effect
1
Clear the basic timer counter value (BTCNT)
Clock Frequency Divider Clear Bit for Basic Timer and Timer/Counters (2)
0
No effect
1
Clear clock frequency dividers
NOTES:
1. When "1" is written to BTCON.1, the basic timer counter value is cleared to "00H". Immediately following the write
operation, the BTCON.1 value is automatically cleared to "0".
2. When "1" is written to BTCON.0, the corresponding frequency divider is cleared to "00H". Immediately following the
write operation, the BTCON.0 value is automatically cleared to "0".
4-6
S3C94A5/F94A5
CONTROL REGISTERS
CLKCON — System Clock Control Register
D4H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7
.6–.5
Oscillator IRQ Wake-up Function Bit
0
Enable IRQ for main wake-up in power down mode
1
Disable IRQ for main wake-up in power down mode
Bits .6–.5
0
.4–.3
.2–.0
Always logic zero
CPU Clock (System Clock) Selection Bits
0
0
Divide by 16 (fxx/16)
0
1
Divide by 8 (fxx/8)
1
0
Divide by 2 (fxx/2)
1
1
Non-divided clock (fxx)
Bits .2–.0
0
Always logic zero
4-7
CONTROL REGISTERS
S3C94A5/F94A5
FLAGS — System Flags Register
D5H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
x
x
x
x
–
–
–
–
R/W
R/W
R/W
R/W
–
–
–
–
Read/Write
.7
Carry Flag (C)
0
.6
.5
.4
.3–.0
4-8
Operation does not generate a carry or borrow condition
Zero Flag (Z)
0
Operation result is a non-zero value
1
Operation result is zero
Sign Flag (S)
0
Operation generates a positive number (MSB = "0")
1
Operation generates a negative number (MSB = "1")
Overflow Flag (V)
0
Operation result is ≤ +127 or ≥ –128
1
Operation result is ≥ +127 or ≤ –128
Not used for S3C94A5/F94A5
S3C94A5/F94A5
CONTROL REGISTERS
INTPND1 — Interrupt Pending Register 1
D6H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
0
0
0
0
0
0
0
Read/Write
–
R/W
R/W
R/W
R/W
R/W
R/W
R/W
.7
Not used for S3C94A5/F94A5
.6
P1.6's Interrupt Pending Bit
.5
.4
.3
.2
.1
.0
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P1.5's Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P1.4's Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P1.3's Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P1.2's Interrupt Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
P1.1's Interrupt Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
P1.0's Interrupt Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
4-9
CONTROL REGISTERS
S3C94A5/F94A5
INTPND2 — Interrupt Pending Register 2
D7H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7
.6
.5
.4
.3
.2
.1
.0
4-10
P5.0's Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P4.7's Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P3.5's Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P3.4's Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
P3.3's Interrupt Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
P3.2's Interrupt Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
P3.1's Interrupt Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
P3.0's Interrupt Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
S3C94A5/F94A5
CONTROL REGISTERS
INTPND3 — Interrupt Pending Register 3
D8H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7
.6
.5
.4
.3
.2
.1
.0
Watch Timer Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
SIO Interrupt Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
Timer 2 Overflow Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
Timer 2 Match or Capture Pending Bit
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
Timer 1 Overflow Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
Timer 1 Match or Capture Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
Timer 0 Overflow Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
Timer 0 Match or Capture Pending Bit
0
No interrupt pending (when read), Clear pending bit (when write)
1
Interrupt is pending (when read)
4-11
CONTROL REGISTERS
S3C94A5/F94A5
P1CONH — Port 1 Control Register (High Byte)
EAH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
0
0
0
0
0
0
Read/Write
–
–
R/W
R/W
R/W
R/W
R/W
R/W
.7–.6
Not used for S3C94A5/F94A5
.5–.4
P1.6/INT Configuration Bits
.3–.2
.1–.0
4-12
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Schmitt trigger input, pull-up
P1.5/INT Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Schmitt trigger input, pull-up
P1.4/INT Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Schmitt trigger input, pull-up
S3C94A5/F94A5
CONTROL REGISTERS
P1CONL — Port 1 Control Register (Low Byte)
EBH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.6
.5–.4
.3–.2
.1–.0
P1.3/INT Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Schmitt trigger input, pull-up
P1.2/INT Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Schmitt trigger input, pull-up
P1.1/INT Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Schmitt trigger input, pull-up
P1.0/INT Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Schmitt trigger input, pull-up
4-13
CONTROL REGISTERS
S3C94A5/F94A5
P1INT — Port 1 Interrupt Control Register
ECH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
0
0
0
0
0
0
0
Read/Write
–
R/W
R/W
R/W
R/W
R/W
R/W
R/W
.7
Not used for S3C94A5/F94A5
.6
P1.6's Interrupt Enable Bit
.5
.4
.3
.2
.1
.0
4-14
0
Disable interrupt
1
Enable interrupt
P1.5's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P1.4's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P1.3's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P1.2's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P1.1's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P1.0's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
S3C94A5/F94A5
CONTROL REGISTERS
P1EDGEH — Port 1 Interrupt Edge Selection Register (High Byte)
EDH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
0
0
0
0
0
0
Read/Write
–
–
R/W
R/W
R/W
R/W
R/W
R/W
.7–.6
Not used for S3C94A5/F94A5
.5–.4
P1.6's Interrupt State Setting Bit
.3–.2
.1–.0
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P1.5's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P1.4's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
4-15
CONTROL REGISTERS
S3C94A5/F94A5
P1EDGEL — Port 1 Interrupt Edge Selection Register (Low Byte)
EEH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.6
.5–.4
.3–.2
.1–.0
4-16
P1.3's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P1.2's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P1.1's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P1.0's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
S3C94A5/F94A5
CONTROL REGISTERS
P2CONH — Port 2 Control Register (High Byte)
EFH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
–
–
0
0
0
0
Read/Write
–
–
–
–
R/W
R/W
R/W
R/W
.7–.4
Not used for S3C94A5/F94A5
.3–.2
P2.5/AD5 Configuration Bits
.1–.0
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD5)
P2.4/AD4 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD4)
4-17
CONTROL REGISTERS
S3C94A5/F94A5
P2CONL — Port 2 Control Register (Low Byte)
F0H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.6
.5–.4
.3–.2
.1–.0
4-18
P2.3/AD3 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD3)
P2.2/AD2 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD2)
P2.1/AD1 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD1)
P2.0/AD0 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD0)
S3C94A5/F94A5
CONTROL REGISTERS
P2PUR — Port 2 Pull-up Control Register
F1H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
0
0
0
0
0
0
Read/Write
–
–
R/W
R/W
R/W
R/W
R/W
R/W
.7–.6
Not used for S3C94A5/F94A5
.5
P2.5's Pull-up Resistor Enable Bit
.4
.3
.2
.1
.0
NOTE:
0
Disable pull-up resistor
1
Enable pull-up resistor
P2.4's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P2.3's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P2.2's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P2.1's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P2.0's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
A pull-up resistor of port 2 is automatically disabled when the corresponding pin is selected as push-pull output or
alternative function.
4-19
CONTROL REGISTERS
S3C94A5/F94A5
P3CONH — Port 3 Control Register (High Byte)
F2H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
0
0
0
0
0
0
0
Read/Write
–
R/W
R/W
R/W
R/W
R/W
R/W
R/W
.7
Not used for S3C94A5/F94A5
.6–.5
P3.5/AD11/T0CLK/INT Configuration Bits
.4–.3
.2–.0
0
0
Schmitt trigger input (T0CLK)
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD11)
P3.4/AD10/T0CAP/INT Configuration Bits
0
0
Schmitt trigger input (T0CAP)
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD10)
P3.3/AD9/T0OUT/T0PWM/INT Configuration Bits
0
0
0
Schmitt trigger input
0
0
1
Push-pull output
0
1
0
N-channel open-drain output
0
1
1
Alternative function (AD9)
1
0
0
Alternative function (T0OUT/T0PWM)
Other Values
4-20
Not available
S3C94A5/F94A5
CONTROL REGISTERS
P3CONL — Port 3 Control Register (Low Byte)
F3H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.6
.5–.3
P3.2/AD8/INT Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD8)
P3.1/AD7/BUZ/INT Configuration Bits
0
0
0
Schmitt trigger input
0
0
1
Push-pull output
0
1
0
N-channel open-drain output
0
1
1
Alternative function (AD7)
1
0
0
Alternative function (BUZ)
Other Values
.2–.0
P3.0/AD6/CLO/INT Configuration Bits
0
0
0
Schmitt trigger input
0
0
1
Push-pull output
0
1
0
N-channel open-drain output
0
1
1
Alternative function (AD6)
1
0
0
Alternative function (CLO)
Other Values
NOTE:
Not available
Not available
CLO is CPU clock output.
4-21
CONTROL REGISTERS
S3C94A5/F94A5
P3INT — Port 3 Interrupt Control Register
F5H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
0
0
0
0
0
0
Read/Write
–
–
R/W
R/W
R/W
R/W
R/W
R/W
.7–.6
Not used for S3C94A5/F94A5
.5
P3.5's Interrupt Enable Bit
.4
.3
.2
.1
.0
4-22
0
Disable interrupt
1
Enable interrupt
P3.4's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P3.3's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P3.2's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P3.1's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P3.0's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
S3C94A5/F94A5
CONTROL REGISTERS
P3EDGEH — Port 3 Interrupt Edge Selection Register (High Byte)
F6H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
–
–
0
0
0
0
Read/Write
–
–
–
–
R/W
R/W
R/W
R/W
.7–.4
Not Used for S3C94A5/F94A5
.3–.2
P3.5's Interrupt State Setting Bit
.1–.0
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P3.4's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
4-23
CONTROL REGISTERS
S3C94A5/F94A5
P3EDGEL — Port 3 Interrupt Edge Selection Register (Low Byte)
F7H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.6
.5–.4
.3–.2
.1–.0
4-24
P3.3's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P3.2's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P3.1's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P3.0's Interrupt State Setting Bit
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
S3C94A5/F94A5
CONTROL REGISTERS
P3PUR — Port 3 Pull-up Control Register
F4H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
0
0
0
0
0
0
Read/Write
–
–
R/W
R/W
R/W
R/W
R/W
R/W
.7–.6
Not used for S3C94A5/F94A5
.5
P3.5's Pull-up Resistor Enable Bit
.4
.3
.2
.1
.0
NOTE:
0
Disable pull-up resistor
1
Enable pull-up resistor
P3.4's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P3.3's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P3.2's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P3.1's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
P3.0's Pull-up Resistor Enable Bit
0
Disable pull-up resistor
1
Enable pull-up resistor
A pull-up resistor of port 3 is automatically disabled when the corresponding pin is selected as push-pull output or
alternative function.
4-25
CONTROL REGISTERS
S3C94A5/F94A5
P4CONH — Port 4 Control Register (High Byte)
F8H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
–
–
0
0
0
0
Read/Write
–
–
–
–
R/W
R/W
R/W
R/W
.7–.4
Not used for S3C94A5/F94A5
.3–.2
P4.7/AD14/INT Configuration Bits
.1–.0
4-26
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (AD14)
P4.6/SCK Configuration Bits
0
0
Schmitt trigger input (SCK input)
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (SCK output)
S3C94A5/F94A5
CONTROL REGISTERS
P4CONM — Port 4 Control Register (Middle Byte)
F9H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.6
.5–.4
.3–.2
.1–.0
P4.5/SI Configuration Bits
0
0
Schmitt trigger input (SI input)
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Not available
P4.4/SO Configuration Bits
0
0
Schmitt trigger input
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Alternative function (SO output)
P4.3/T2CAP Configuration Bits
0
0
Schmitt trigger input (T2CAP)
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Not available
P4.2/T1CAP Configuration Bits
0
0
Schmitt trigger input (T1CAP)
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Not available
4-27
CONTROL REGISTERS
S3C94A5/F94A5
P4CONL — Port 4 Control Register (Low Byte)
FAH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
0
0
0
0
0
0
Read/Write
–
–
R/W
R/W
R/W
R/W
R/W
R/W
.7–.6
Not used for S3C94A5/F94A5
.5–.3
P4.1/AD13/T2OUT/T2PWM Configuration Bits
0
0
0
Schmitt trigger input
0
0
1
Push-pull output
0
1
0
N-channel open-drain output
0
1
1
Alternative function (T2OUT/T2PWM)
1
0
0
Alternative function (AD13)
Other Values
.2–.0
P4.0/AD12/T1OUT/T1PWM Configuration Bits
0
0
0
Schmitt trigger input
0
0
1
Push-pull output
0
1
0
N-channel open-drain output
0
1
1
Alternative function (T1OUT/T1PWM)
1
0
0
Alternative function (AD12)
Other Values
4-28
Not available
Not available
S3C94A5/F94A5
CONTROL REGISTERS
P4n5INT — Port 4 and 5 Interrupt Control Register
FBH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
0
0
0
0
0
0
Read/Write
–
–
R/W
R/W
R/W
R/W
R/W
R/W
.7–.6
Not used for S3C94A5/F94A5
.5
P5.0's Interrupt Enable Bit
.4
.3–.2
.1–.0
0
Disable interrupt
1
Enable interrupt
P4.7's Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
P5.0's Interrupt State Setting Bits
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
P4.7's Interrupt State Setting Bits
0
0
Falling edge interrupt
0
1
Rising edge interrupt
1
0
Both rising and falling edges interrupt
1
1
Not available
4-29
CONTROL REGISTERS
S3C94A5/F94A5
P4PUR — Port 4 Pull-up Control Register
Bit Identifier
RESET Value
Read/Write
.7
0
R/W
.6
0
R/W
.5
0
R/W
FCH
.4
0
R/W
.7
P4.7's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
.6
P4.6's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
.5
P4.5's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
.4
P4.4's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
.3
P4.3's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
.2
P4.2's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
.1
P4.1's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
.0
P4.0's Pull-up Resistor Enable Bit
0 Disable pull-up resistor
1 Enable pull-up resistor
NOTE:
4-30
.3
0
R/W
.2
0
R/W
.1
0
R/W
.0
0
R/W
A pull-up resistor of port 4 is automatically disabled when the corresponding pin is selected as push-pull output or
alternative function.
S3C94A5/F94A5
CONTROL REGISTERS
P5CONH — Port 5 Control Register (High Byte)
FDH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.6
.5–.4
.3–.2
.1–.0
P5.6 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Input, pull-up mode
P5.5 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Input, pull-up mode
P5.4 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Input, pull-up mode
P5.3 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Input, pull-up mode
4-31
CONTROL REGISTERS
S3C94A5/F94A5
P5CONL — Port 5 Control Register (Low Byte)
FEH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
0
0
0
0
0
0
0
Read/Write
–
R/W
R/W
R/W
R/W
R/W
R/W
R/W
.7
Not Used for S3C94A5/F94A5
.6–.5
P5.2 Configuration Bits
.4–.3
.2–.0
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Input, pull-up mode
P5.1 Configuration Bits
0
0
Input mode
0
1
Push-pull output
1
0
N-channel open-drain output
1
1
Input, pull-up mode
P5.0/AD15/INT Configuration Bits
0
0
0
Input mode
0
0
1
Push-pull output
0
1
0
N-channel open-drain output
0
1
1
Input, pull-up mode
1
0
0
Alternative function (AD15)
Other Values
4-32
Not available
S3C94A5/F94A5
CONTROL REGISTERS
SIOCON — SIO Control Register
E1H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
–
R/W
R/W
R/W
R/W
R/W
R/W
R/W
–
Read/Write
.7
.6
.5
.4
.3
.2
.1
.0
SIO Shift Clock Selection Bit
0
Internal clock (P.S clock)
1
External clock (SCK)
Data Direction Control Bit
0
MSB-first mode
1
LSB-first mode
SIO Mode Selection Bit
0
Receive-only mode
1
Transmit/receive mode
Shift Clock Edge Selection Bit
0
Tx at falling edges, Rx at rising edges
1
Tx at rising edges, Rx at falling edges
SIO Counter Clear and Shift Start Bit
0
No action
1
Clear 3-bit counter and start shifting
SIO Shift Operation Enable Bit
0
Disable shifter and clock counter
1
Enable shifter and clock counter
SIO Interrupt Enable Bit
0
Disable SIO interrupt
1
Enable SIO interrupt
Not used for S3C94A5/F94A5
4-33
CONTROL REGISTERS
S3C94A5/F94A5
STPCON — Stop Control Register
E0H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.0
Stop Control Bits
1
0
1
0
0
Other Values
NOTE:
4-34
1
0
1
Enable stop instruction
Disable stop instruction
Before executing the STOP instruction, the STPCON register must be set to "10100101B". Otherwise the STOP
instruction will not execute.
S3C94A5/F94A5
CONTROL REGISTERS
SYM — System Mode Register
DFH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
–
–
–
0
0
0
0
Read/Write
–
–
–
–
R/W
R/W
R/W
R/W
.7–.4
Not used for S3C94A5/F94A5
.3
Global Interrupt Enable Bit
.2–.0
0
Global interrupt processing disable (DI instruction)
1
Global interrupt processing enable (EI instruction)
Page Selection Bits
0
0
0
Page 0
0
0
1
Page 1
Other Values
Not available
4-35
CONTROL REGISTERS
S3C94A5/F94A5
T0CON — Timer 0 Control Register
B4H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.5
.4–.3
.2
.1
.0
4-36
Timer 0 Input Clock Selection Bits
0
0
0
fxx/1024
0
0
1
fxx/256
0
1
0
fxx/64
0
1
1
fxx/8
1
0
0
fxx
1
0
1
External clock falling edge (T0CLK)
1
1
0
External clock rising edge (T0CLK)
1
1
1
Counter stop
Timer 0 Operating Mode Selection Bits
0
0
Interval mode
0
1
Capture mode (capture on rising edge, counter running, OVF can occur)
1
0
Capture mode (capture on falling edge, counter running, OVF can occur)
1
1
PWM mode (OVF & match interrupt can occur)
Timer 0 Counter Clear Bit
0
No effect
1
Clear the timer 0 counter (when write)
Timer 0 Match/Capture Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
Timer 0 Overflow Interrupt Enable Bit
0
Disable overflow interrupt
1
Enable overflow interrupt
S3C94A5/F94A5
CONTROL REGISTERS
T1CON — Timer 1 Control Register
B9H
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.5
.4–.3
.2
.1
.0
Timer 1 Input Clock Selection Bits
0
0
0
fxx/1024
0
0
1
fxx/256
0
1
0
fxx/64
0
1
1
fxx/8
1
0
0
fxx
1
1
1
Counter stop
Other Values
Not available
Timer 1 Operating Mode Selection Bits
0
0
Interval mode
0
1
Capture mode (capture on rising edge, counter running, OVF can occur)
1
0
Capture mode (capture on falling edge, counter running, OVF can occur)
1
1
PWM mode (OVF & match interrupt can occur)
Timer 1 Counter Enable Bit
0
No effect
1
Clear the timer 1 counter (when write)
Timer 1 Match/Capture Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
Timer 1 Overflow Interrupt Enable Bit
0
Disable overflow interrupt
1
Enable overflow interrupt
4-37
CONTROL REGISTERS
S3C94A5/F94A5
T2CON — Timer 2 Control Register
BEH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read/Write
.7–.5
.4–.3
.2
.1
.0
4-38
Timer 2 Input Clock Selection Bits
0
0
0
fxx/1024
0
0
1
fxx/256
0
1
0
fxx/64
0
1
1
fxx/8
1
0
0
fxx
1
1
1
Counter stop
Other Values
Not available
Timer 2 Operating Mode Selection Bits
0
0
Interval mode
0
1
Capture mode (capture on rising edge, counter running, OVF can occur)
1
0
Capture mode (capture on falling edge, counter running, OVF can occur)
1
1
PWM mode (OVF & match interrupt can occur)
Timer 2 Counter Clear Bit
0
No effect
1
Clear the timer 2 counter (when write)
Timer 2 Match/Capture Interrupt Enable Bit
0
Disable interrupt
1
Enable interrupt
Timer 2 Overflow Interrupt Enable Bit
0
Disable overflow interrupt
1
Enable overflow interrupt
S3C94A5/F94A5
CONTROL REGISTERS
WTCON — Watch Timer Control Register
DAH
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
–
0
0
0
0
0
0
–
Read/Write
–
R/W
R/W
R/W
R/W
R/W
R/W
–
.7
Not used for S3C94A5/F94A5
.6
Watch Timer Interrupt Enable Bit
.5–.4
.3–.2
.1
.0
0
Disable watch timer interrupt
1
Enable watch timer interrupt
Buzzer Signal Selection Bits (fx = 4.19 MHz)
0
0
0.5 kHz
0
1
1 kHz
1
0
2 kHz
1
1
4 kHz
Watch Timer Speed Selection Bits (fx = 4.19 MHz)
0
0
Set watch timer interrupt to 1s
0
1
Set watch timer interrupt to 0.5s
1
0
Set watch timer interrupt to 0.25s
1
1
Set watch timer interrupt to 3.91ms
Watch Timer Enable Bit
0
Disable watch timer; Clear frequency dividing circuits
1
Enable watch timer
Not used for S3C94A5/F94A5
4-39
S3C94A5/F94A5
5
INTERRUPT STRUCTURE
INTERRUPT STRUCTURE
OVERVIEW
The SAM88RCRI interrupt structure has two basic components: a vector, and sources. The number of interrupt
sources can be serviced through a interrupt vector which is assigned in ROM address 0000H – 0001H.
VECTOR
SOURCES
S1
0000H
0001H
S2
S3
Sn
NOTES:
1. The SAM88RCRI interrupt has only one vector address (0000H-0001H).
2. The number of Sn value is expandable.
Figure 5-1. S3C9-Series Interrupt Type
INTERRUPT PROCESSING CONTROL POINTS
Interrupt processing can be controlled in two ways: globally, or by specific interrupt level and source. The systemlevel control points in the interrupt structure are therefore:
— Global interrupt enable and disable (by EI and DI instructions)
— Interrupt source enable and disable settings in the corresponding peripheral control register(s)
ENABLE/DISABLE INTERRUPT INSTRUCTIONS (EI, DI)
The system mode register, SYM (DFH), is used to enable and disable interrupt processing.
SYM.3 is the enable and disable bit for global interrupt processing, which you can set by modifying SYM.3. An
Enable Interrupt (EI) instruction must be included in the initialization routine that follows a reset operation in order to
enable interrupt processing. Although you can manipulate SYM.3 directly to enable and disable interrupts during
normal operation, we recommend that you use the EI and DI instructions for this purpose.
5-1
INTERRUPT STRUCTURE
S3C94A5/F94A5
INTERRUPT PENDING FUNCTION TYPES
When the interrupt service routine has executed, the application program's service routine must clear the appropriate
pending bit before the return from interrupt subroutine (IRET) occurs.
INTERRUPT PRIORITY
Because there is not a interrupt priority register in SAM88RCRI, the order of service is determined by a sequence of
source which is executed in interrupt service routine.
"EI" Instruction
Execution
S
nRESET
R
Source
Interrupts
Source
Interrupt
Enable
Q
Interrupt Pending
Register
Interrpt priority
is determind by
software polling
method
Global Interrupt
Control (EI, Di instruction)
Figure 5-2. Interrupt Function Diagram
5-2
Vector
Interrupt
Cycle
S3C94A5/F94A5
INTERRUPT STRUCTURE
INTERRUPT SOURCE SERVICE SEQUENCE
The interrupt request polling and servicing sequence is as follows:
1.
A source generates an interrupt request by setting the interrupt request pending bit to "1".
2.
The CPU generates an interrupt acknowledge signal.
3.
The service routine starts and the source's pending flag is cleared to "0" by software.
4.
Interrupt priority must be determined by software polling method.
INTERRUPT SERVICE ROUTINES
Before an interrupt request can be serviced, the following conditions must be met:
— Interrupt processing must be enabled (EI, SYM.3 = "1")
— Interrupt must be enabled at the interrupt's source (peripheral control register)
If all of the above conditions are met, the interrupt request is acknowledged at the end of the instruction cycle. The
CPU then initiates an interrupt machine cycle that completes the following processing sequence:
1.
Reset (clear to "0") the global interrupt enable bit in the SYM register (DI, SYM.3 = "0")
to disable all subsequent interrupts.
2.
Save the program counter and status flags to stack.
3.
Branch to the interrupt vector to fetch the service routine's address.
4.
Pass control to the interrupt service routine.
When the interrupt service routine is completed, an Interrupt Return instruction (IRET) occurs. The IRET restores the
PC and status flags and sets SYM.3 to "1"(EI), allowing the CPU to process the next interrupt request.
GENERATING INTERRUPT VECTOR ADDRESSES
The interrupt vector area in the ROM contains the address of the interrupt service routine. Vectored interrupt
processing follows this sequence:
1.
Push the program counter's low-byte value to stack.
2.
Push the program counter's high-byte value to stack.
3.
Push the FLAGS register values to stack.
4.
Fetch the service routine's high-byte address from the vector address 0000H.
5.
Fetch the service routine's low-byte address from the vector address 0001H.
6.
Branch to the service routine specified by the 16-bit vector address.
5-3
INTERRUPT STRUCTURE
S3C94A5/F94A5 INTERRUPT STRUCTURE
The S3C94A5/F94A5 microcontroller has twenty three peripheral interrupt sources:
— Timer 0 match/capture interrupt
— Timer 0 overflow interrupt
— Timer 1 match/capture interrupt
— Timer 1 overflow interrupt
— Timer 2 match/capture interrupt
— Timer 2 overflow interrupt
— SIO interrupt
— Watch Timer interrupt
— Seven external interrupts for port 1
— Six external interrupts for port 3
— One external interrupt for port 4
— One external interrupt for port 5
5-4
S3C94A5/F94A5
S3C94A5/F94A5
INTERRUPT STRUCTURE
Vector
Enable/Disable
Pending
Sources
INTPND1.0
P1.0 External Interript
INTPND1.1
P1.1 External Interript
INTPND1.2
P1.2 External Interript
INTPND1.3
P1.3 External Interript
INTPND1.4
P1.4 External Interript
INTPND1.5
P1.5 External Interript
INTPND1.6
P1.6 External Interript
INTPND2.0
P3.0 External Interrupt
INTPND2.1
P3.1 External Interrupt
INTPND2.2
P3.2 External Interrupt
INTPND2.3
P3.3 External Interrupt
INTPND2.4
P3.4 External Interrupt
INTPND2.5
P3.5 External Interrupt
INTPND2.6
P4.7 External Interrupt
INTPND2.7
P5.0 External Interript
INTPND3.0
Timer 0 Match or Capture
INTPND3.1
Timer 0 Overflow
INTPND3.2
Timer 1 Match or Capture
INTPND3.3
Timer 1 Overflow
INTPND3.4
Timer 2 Match or Capture
INTPND3.5
Timer 2 Overflow
INTPND3.6
SIO Interrupt
INTPND3.7
Watch Timer Interrupt
P1INT.0
P1INT.1
P1INT.2
P1INT.3
P1INT.4
P1INT.5
P1INT.6
0000H
0001H
P3INT.0
SYM.3
(EI, DI)
P3INT.1
P3INT.2
P3INT.3
P3ITN.4
P3INT.5
P4n5INT.4
P4n5INT.5
T0CON.1
T0CON.0
T1CON.1
T1CON.0
T2CON.1
T2CON.0
SIOCON.1
WTCON.6
Figure 5-3. S3C94A5/F94A5 Interrupt Structure
5-5
INTERRUPT STRUCTURE
F
S3C94A5/F94A5
Programming Tip — How to clear an interrupt pending bit
As the following examples are shown, a load instruction should be used to clear an interrupt pending bit.
Examples:
1.
LD
INTPND1, #11111011B
; Clear P1.2's interrupt pending bit
INTPND3, #01111111B
; Clear watch timer interrupt pending bit
•
•
•
IRET
2.
LD
•
•
•
IRET
5-6
S3C94A5/F94A5
6
SAM88RCRI INSTRUCTION SET
SAM88RCRI INSTRUCTION SET
OVERVIEW
The SAM88RCRI instruction set is designed to support the large register file. It includes a full complement of 8-bit
arithmetic and logic operations. There are 41 instructions. No special I/O instructions are necessary because I/O
control and data registers are mapped directly into the register file. Flexible instructions for bit addressing, rotate, and
shift operations complete the powerful data manipulation capabilities of the SAM88RCRI instruction set.
REGISTER ADDRESSING
To access an individual register, an 8-bit address in the range 0-255 or the 4-bit address of a working register is
specified. Paired registers can be used to construct 16-bit program memory or data memory addresses. For detailed
information about register addressing, please refer to Section 2, "Address Spaces".
ADDRESSING MODES
There are six addressing modes: Register (R), Indirect Register (IR), Indexed (X), Direct (DA), Relative (RA), and
Immediate (IM). For detailed descriptions of these addressing modes, please refer to Section 3, "Addressing Modes".
6-1
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
Table 6-1. Instruction Group Summary
Mnemonic
Operands
Instruction
CLR
dst
Clear
LD
dst,src
Load
LDC
dst,src
Load program memory
LDE
dst,src
Load external data memory
LDCD
dst,src
Load program memory and decrement
LDED
dst,src
Load external data memory and decrement
LDCI
dst,src
Load program memory and increment
LDEI
dst,src
Load external data memory and increment
POP
dst
Pop from stack
PUSH
src
Push to stack
ADC
dst,src
Add with carry
ADD
dst,src
Add
CP
dst,src
Compare
DEC
dst
Decrement
INC
dst
Increment
SBC
dst,src
Subtract with carry
SUB
dst,src
Subtract
AND
dst,src
Logical AND
COM
dst
Complement
OR
dst,src
Logical OR
XOR
dst,src
Logical exclusive OR
Load Instructions
Arithmetic Instructions
Logic Instructions
6-2
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
Table 6-1. Instruction Group Summary (Continued)
Mnemonic
Operands
Instruction
Program Control Instructions
CALL
dst
IRET
Call procedure
Interrupt return
JP
cc,dst
Jump on condition code
JP
dst
Jump unconditional
JR
cc,dst
Jump relative on condition code
RET
Return
Bit Manipulation Instructions
TCM
dst,src
Test complement under mask
TM
dst,src
Test under mask
Rotate and Shift Instructions
RL
dst
Rotate left
RLC
dst
Rotate left through carry
RR
dst
Rotate right
RRC
dst
Rotate right through carry
SRA
dst
Shift right arithmetic
CPU Control Instructions
CCF
Complement carry flag
DI
Disable interrupts
EI
Enable interrupts
IDLE
Enter Idle mode
NOP
No operation
RCF
Reset carry flag
SCF
Set carry flag
STOP
Enter Stop mode
6-3
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
FLAGS REGISTER (FLAGS)
The FLAGS register contains eight bits that describe the current status of CPU operations. Four of these bits,
FLAGS.4 – FLAGS.7, can be tested and used with conditional jump instructions;
FLAGS register can be set or reset by instructions as long as its outcome does not affect the flags, such as, Load
instruction. Logical and Arithmetic instructions such as, AND, OR, XOR, ADD, and SUB can affect the Flags register.
For example, the AND instruction updates the Zero, Sign and Overflow flags based on the outcome of the AND
instruction. If the AND instruction uses the Flags register as the destination, then simultaneously, two write will occur
to the Flags register producing an unpredictable result.
System Flags Register (FLAGS)
D5H, R/W
MSB
.7
.6
.5
Carry flag (C)
.4
.3
.2
.1
.0
LSB
Not mapped
Zero flag (Z)
Sign flag (S)
Overflow flag (V)
Figure 6-1. System Flags Register (FLAGS)
FLAG DESCRIPTIONS
Overflow Flag (FLAGS.4, V)
The V flag is set to "1" when the result of a two's-complement operation is greater than + 127 or less than – 128. It is
also cleared to "0" following logic operations.
Sign Flag (FLAGS.5, S)
Following arithmetic, logic, rotate, or shift operations, the sign bit identifies the state of the MSB of the result. A logic
zero indicates a positive number and a logic one indicates a negative number.
Zero Flag (FLAGS.6, Z)
For arithmetic and logic operations, the Z flag is set to "1" if the result of the operation is zero. For operations that
test register bits, and for shift and rotate operations, the Z flag is set to "1" if the result is logic zero.
Carry Flag (FLAGS.7, C)
The C flag is set to "1" if the result from an arithmetic operation generates a carry-out from or a borrow to the bit 7
position (MSB). After rotate and shift operations, it contains the last value shifted out of the specified register.
Program instructions can set, clear, or complement the carry flag.
6-4
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
INSTRUCTION SET NOTATION
Table 6-2. Flag Notation Conventions
Flag
Description
C
Carry flag
Z
Zero flag
S
Sign flag
V
Overflow flag
0
Cleared to logic zero
1
Set to logic one
*
Set or cleared according to operation
–
Value is unaffected
x
Value is undefined
Table 6-3. Instruction Set Symbols
Symbol
Description
dst
Destination operand
src
Source operand
@
Indirect register address prefix
PC
Program counter
FLAGS
Flags register (D5H)
#
Immediate operand or register address prefix
H
Hexadecimal number suffix
D
Decimal number suffix
B
Binary number suffix
opc
Opcode
6-5
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
Table 6-4. Instruction Notation Conventions
Notation
cc
Actual Operand Range
Condition code
See list of condition codes in Table 6-6.
r
Working register only
Rn (n = 0–15)
rr
Working register pair
RRp (p = 0, 2, 4, ..., 14)
R
Register or working register
reg or Rn (reg = 0–255, n = 0–15)
Register pair or working register pair
reg or RRp (reg = 0–254, even number only, where
p = 0, 2, ..., 14)
Ir
Indirect working register only
@Rn (n = 0–15)
IR
Indirect register or indirect working register
@Rn or @reg (reg = 0–255, n = 0–15)
Irr
Indirect working register pair only
@RRp (p = 0, 2, ..., 14)
Indirect register pair or indirect working
register pair
@RRp or @reg (reg = 0–254, even only, where
p = 0, 2, ..., 14)
Indexed addressing mode
#reg[Rn] (reg = 0–255, n = 0–15)
XS
Indexed (short offset) addressing mode
#addr[RRp] (addr = range –128 to +127, where
p = 0, 2, ..., 14)
xl
Indexed (long offset) addressing mode
#addr [RRp] (addr = range 0–8191, where
p = 0, 2, ..., 14)
da
Direct addressing mode
addr (addr = range 0–8191)
ra
Relative addressing mode
addr (addr = number in the range +127 to –128 that is
an offset relative to the address of the next instruction)
im
Immediate addressing mode
#data (data = 0–255)
RR
IRR
X
6-6
Description
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
Table 6-5. Opcode Quick Reference
OPCODE MAP
LOWER NIBBLE (HEX)
–
0
1
2
3
4
5
6
U
0
DEC
R1
DEC
IR1
ADD
r1,r2
ADD
r1,Ir2
ADD
R2,R1
ADD
IR2,R1
ADD
R1,IM
P
1
RLC
R1
RLC
IR1
ADC
r1,r2
ADC
r1,Ir2
ADC
R2,R1
ADC
IR2,R1
ADC
R1,IM
P
2
INC
R1
INC
IR1
SUB
r1,r2
SUB
r1,Ir2
SUB
R2,R1
SUB
IR2,R1
SUB
R1,IM
E
3
JP
IRR1
SBC
r1,r2
SBC
r1,Ir2
SBC
R2,R1
SBC
IR2,R1
SBC
R1,IM
R
4
OR
r1,r2
OR
r1,Ir2
OR
R2,R1
OR
IR2,R1
OR
R1,IM
5
POP
R1
POP
IR1
AND
r1,r2
AND
r1,Ir2
AND
R2,R1
AND
IR2,R1
AND
R1,IM
N
6
COM
R1
COM
IR1
TCM
r1,r2
TCM
r1,Ir2
TCM
R2,R1
TCM
IR2,R1
TCM
R1,IM
I
7
PUSH
R2
PUSH
IR2
TM
r1,r2
TM
r1,Ir2
TM
R2,R1
TM
IR2,R1
TM
R1,IM
B
8
B
9
L
A
E
B
CLR
R1
CLR
IR1
C
RRC
R1
RRC
IR1
LDC
r1,Irr2
H
D
SRA
R1
SRA
IR1
LDC
r2,Irr1
E
E
RR
R1
RR
IR1
X
F
7
LD
r1, x, r2
RL
R1
RL
IR1
LD
r2, x, r1
CP
r1,r2
CP
r1,Ir2
CP
R2,R1
CP
IR2,R1
CP
R1,IM
LDC
r1, Irr2, xL
XOR
r1,r2
XOR
r1,Ir2
XOR
R2,R1
XOR
IR2,R1
XOR
R1,IM
LDC
r2, Irr2, xL
LDCD
r1,Irr2
LDCI
r1,Irr2
LD
r1, Ir2
LD
IR1,IM
LD
Ir1, r2
LD
R2,R1
LD
R2,IR1
LD
R1,IM
LDC
r1, Irr2, xs
CALL
IRR1
LD
IR2,R1
CALL
DA1
LDC
r2, Irr1, xs
6-7
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
Table 6-5. Opcode Quick Reference (Continued)
OPCODE MAP
LOWER NIBBLE (HEX)
–
8
9
U
0
LD
r1,R2
P
1
↓
P
2
E
3
R
4
A
B
C
D
E
LD
r2,R1
JR
cc,RA
LD
r1,IM
JP
cc,DA
INC
r1
↓
↓
↓
↓
↓
F
5
N
6
I
7
B
8
DI
B
9
EI
L
A
RET
E
B
IRET
C
RCF
H
D
E
E
X
F
6-8
IDLE
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
STOP
SCF
CCF
LD
r1,R2
LD
r2,R1
JR
cc,RA
LD
r1,IM
JP
cc,DA
INC
r1
NOP
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
CONDITION CODES
The opcode of a conditional jump always contains a 4-bit field called the condition code (cc). This specifies under
which conditions it is to execute the jump. For example, a conditional jump with the condition code for "equal" after a
compare operation only jumps if the two operands are equal. Condition codes are listed in Table 6-6.
The carry (C), zero (Z), sign (S), and overflow (V) flags are used to control the operation of conditional jump
instructions.
Table 6-6. Condition Codes
Binary
Mnemonic
Description
Flags Set
0000
F
Always false
–
1000
T
Always true
–
0111 (1)
C
Carry
C=1
1111 (1)
NC
No carry
C=0
0110 (1)
Z
Zero
Z=1
1110 (1)
NZ
Not zero
Z=0
1101
PL
Plus
S=0
0101
MI
Minus
S=1
0100
OV
Overflow
V=1
1100
NOV
No overflow
V=0
0110 (1)
EQ
Equal
Z=1
1110 (1)
NE
Not equal
Z=0
1001
GE
Greater than or equal
(S XOR V) = 0
0001
LT
Less than
(S XOR V) = 1
1010
GT
Greater than
(Z OR (S XOR V)) = 0
0010
LE
Less than or equal
(Z OR (S XOR V)) = 1
1111 (1)
UGE
Unsigned greater than or equal
C=0
0111 (1)
ULT
Unsigned less than
C=1
1011
UGT
Unsigned greater than
(C = 0 AND Z = 0) = 1
0011
ULE
Unsigned less than or equal
(C OR Z) = 1
NOTES:
1. Indicate condition codes that are related to two different mnemonics but which test the same flag.
For example, Z and EQ are both true if the zero flag (Z) is set, but after an ADD instruction, Z would probably be used;
after a CP instruction, however, EQ would probably be used.
2. For operations involving unsigned numbers, the special condition codes UGE, ULT, UGT, and ULE must be us ed.
6-9
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
INSTRUCTION DESCRIPTIONS
This section contains detailed information and programming examples for each instruction in the SAM88RCRI
instruction set. Information is arranged in a consistent format for improved readability and for fast referencing. The
following information is included in each instruction description:
— Instruction name (mnemonic)
— Full instruction name
— Source/destination format of the instruction operand
— Shorthand notation of the instruction's operation
— Textual description of the instruction's effect
— Specific flag settings affected by the instruction
— Detailed description of the instruction's format, execution time, and addressing mode(s)
— Programming example(s) explaining how to use the instruction
6-10
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
ADC — Add With Carry
ADC
dst,src
Operation:
dst ¨ dst + src + c
The source operand, along with the setting of the carry flag, is added to the destination operand and
the sum is stored in the destination. The contents of the source are unaffected. Two's-complement
addition is performed. In multiple precision arithmetic, this instruction permits the carry from the
addition of low-order operands to be carried into the addition of high-order operands.
Flags:
C:
Z:
S:
V:
Set if there is a carry from the most significant bit of the result; cleared otherwise.
Set if the result is "0"; cleared otherwise.
Set if the result is negative; cleared otherwise.
Set if arithmetic overflow occurs, that is, if both operands are of the same sign and the
result is of the opposite sign; cleared otherwise.
Always cleared to "0".
Set if there is a carry from the most significant bit of the low-order four bits of the result;
cleared otherwise.
D:
H:
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
12
r
r
6
13
r
lr
6
14
R
R
6
15
R
IR
6
16
R
IM
3
3
Addr Mode
dst
src
Given: R1 = 10H, R2 = 03H, C flag = "1", register 01H = 20H, register 02H = 03H, and register
03H = 0AH:
ADC
ADC
ADC
ADC
ADC
R1,R2
R1,@R2
01H,02H
01H,@02H
01H,#11H
→
→
→
→
→
R1 = 14H, R2 = 03H
R1 = 1BH, R2 = 03H
Register 01H = 24H, register 02H = 03H
Register 01H = 2BH, register 02H = 03H
Register 01H = 32H
In the first example, destination register R1 contains the value 10H, the carry flag is set to "1", and
the source working register R2 contains the value 03H. The statement "ADC R1,R2" adds 03H and
the carry flag value ("1") to the destination value 10H, leaving 14H in register R1.
6-11
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
ADD — Add
ADD
dst,src
Operation:
dst ¨ dst + src
The source operand is added to the destination operand and the sum is stored in the destination.
The contents of the source are unaffected. Two's-complement addition is performed.
Flags:
C:
Z:
S:
V:
Set if there is a carry from the most significant bit of the result; cleared otherwise.
Set if the result is "0"; cleared otherwise.
Set if the result is negative; cleared otherwise.
Set if arithmetic overflow occurred, that is, if both operands are of the same sign and the
result is of the opposite sign; cleared otherwise.
Always cleared to "0".
Set if a carry from the low-order nibble occurred.
D:
H:
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
02
r
r
6
03
r
lr
6
04
R
R
6
05
R
IR
6
06
R
IM
3
3
Addr Mode
dst
src
Given: R1 = 12H, R2 = 03H, register 01H = 21H, register 02H = 03H, register 03H = 0AH:
ADD
ADD
ADD
ADD
ADD
R1,R2
R1,@R2
01H,02H
01H,@02H
01H,#25H
→
→
→
→
→
R1 = 15H, R2 = 03H
R1 = 1CH, R2 = 03H
Register 01H = 24H, register 02H = 03H
Register 01H = 2BH, register 02H = 03H
Register 01H = 46H
In the first example, destination working register R1 contains 12H and the source working register R2
contains 03H. The statement "ADD R1,R2" adds 03H to 12H, leaving the value 15H in register R1.
6-12
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
AND — Logical AND
AND
dst,src
Operation:
dst ¨ dst AND src
The source operand is logically ANDed with the destination operand. The result is stored in the
destination. The AND operation results in a "1" bit being stored whenever the corresponding bits in
the two operands are both logic ones; otherwise a "0" bit value is stored. The contents of the source
are unaffected.
Flags:
C:
Z:
S:
V:
D:
H:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Always cleared to "0".
Unaffected.
Unaffected.
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
52
r
r
6
53
r
lr
6
54
R
R
6
55
R
IR
6
56
R
IM
3
3
Addr Mode
dst
src
Given: R1 = 12H, R2 = 03H, register 01H = 21H, register 02H = 03H, register 03H = 0AH:
AND
AND
AND
AND
AND
R1,R2
R1,@R2
01H,02H
01H,@02H
01H,#25H
→
→
→
→
→
R1 = 02H, R2 = 03H
R1 = 02H, R2 = 03H
Register 01H = 01H, register 02H = 03H
Register 01H = 00H, register 02H = 03H
Register 01H = 21H
In the first example, destination working register R1 contains the value 12H and the source working
register R2 contains 03H. The statement "AND R1,R2" logically ANDs the source operand 03H with
the destination operand value 12H, leaving the value 02H in register R1.
6-13
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
CALL — Call Procedure
CALL
dst
Operation:
SP
@SP
SP
@SP
PC
¨
¨
¨
¨
¨
SP – 1
PCL
SP –1
PCH
dst
The current contents of the program counter are pushed onto the top of the stack. The program
counter value used is the address of the first instruction following the CALL instruction. The specified
destination address is then loaded into the program counter and points to the first instruction of a
procedure. At the end of the procedure the return instruction (RET) can be used to return to the
original program flow. RET pops the top of the stack back into the program counter.
Flags:
No flags are affected.
Format:
opc
opc
Examples:
dst
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
3
14
F6
DA
2
12
F4
IRR
Given: R0 = 15H, R1 = 21H, PC = 1A47H, and SP = 0B2H:
CALL
1521H
→
CALL
@RR0
→
SP = 0B0H
(Memory locations 00H = 1AH, 01H = 4AH, where 4AH
is the address that follows the instruction.)
SP = 0B0H (00H = 1AH, 01H = 49H)
In the first example, if the program counter value is 1A47H and the stack pointer contains the value
0B2H, the statement "CALL 1521H" pushes the current PC value onto the top of the stack. The
stack pointer now points to memory location 00H. The PC is then loaded with the value 1521H, the
address of the first instruction in the program sequence to be executed.
If the contents of the program counter and stack pointer are the same as in the first example, the
statement "CALL @RR0" produces the same result except that the 49H is stored in stack location
01H (because the two-byte instruction format was used). The PC is then loaded with the value
1521H, the address of the first instruction in the program sequence to be executed.
6-14
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
CCF — Complement Carry Flag
CCF
Operation:
C ¨ NOT C
The carry flag (C) is complemented. If C = "1", the value of the carry flag is changed to logic zero;
if C = "0", the value of the carry flag is changed to logic one.
Flags:
C:
Complemented.
No other flags are affected.
Format:
opc
Example:
Bytes
Cycles
Opcode
(Hex)
1
4
EF
Given: The carry flag = "0":
CCF
If the carry flag = "0", the CCF instruction complements it in the FLAGS register (0D5H), changing
its value from logic zero to logic one.
6-15
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
CLR — Clear
CLR
dst
Operation:
dst ¨ "0"
The destination location is cleared to "0".
Flags:
No flags are affected.
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
B0
R
4
B1
IR
Given: Register 00H = 4FH, register 01H = 02H, and register 02H = 5EH:
CLR
CLR
00H
@01H
→
→
Register 00H = 00H
Register 01H = 02H, register 02H = 00H
In Register (R) addressing mode, the statement "CLR 00H" clears the destination register 00H
value to 00H. In the second example, the statement "CLR @01H" uses Indirect Register (IR)
addressing mode to clear the 02H register value to 00H.
6-16
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
COM — Complement
COM
dst
Operation:
dst ¨ NOT dst
The contents of the destination location are complemented (one's complement); all "1s" are changed
to "0s", and vice-versa.
Flags:
C:
Z:
S:
V:
D:
H:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Always reset to "0".
Unaffected.
Unaffected.
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
60
R
4
61
IR
Given: R1 = 07H and register 07H = 0F1H:
COM
COM
R1
@R1
→
→
R1 = 0F8H
R1 = 07H, register 07H = 0EH
In the first example, destination working register R1 contains the value 07H (00000111B). The
statement "COM R1" complements all the bits in R1: all logic ones are changed to logic zeros, and
vice-versa, leaving the value 0F8H (11111000B).
In the second example, Indirect Register (IR) addressing mode is used to complement the value of
destination register 07H (11110001B), leaving the new value 0EH (00001110B).
6-17
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
CP — Compare
CP
dst,src
Operation:
dst – src
The source operand is compared to (subtracted from) the destination operand, and the appropriate
flags are set accordingly. The contents of both operands are unaffected by the comparison.
Flags:
C:
Z:
S:
V:
D:
H:
Set if a "borrow" occurred (src > dst); cleared otherwise.
Set if the result is "0"; cleared otherwise.
Set if the result is negative; cleared otherwise.
Set if arithmetic overflow occurred, that is, if the operands were of opposite signs and the
sign of the result is of the same as the sign of the source operand; cleared otherwise.
Unaffected.
Unaffected.
Format:
opc
opc
opc
Examples:
1.
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
A2
r
r
6
A3
r
lr
6
A4
R
R
6
A5
R
IR
6
A6
R
IM
3
3
Addr Mode
dst
src
Given: R1 = 02H and R2 = 03H:
CP
R1,R2
→
Set the C and S flags
Destination working register R1 contains the value 02H and source register R2 contains the value
03H. The statement "CP R1,R2" subtracts the R2 value (source/subtrahend) from the R1 value
(destination/minuend). Because a "borrow" occurs and the difference is negative, C and S are "1".
2.
Given: R1 = 05H and R2 = 0AH:
SKIP
CP
JP
INC
LD
R1,R2
UGE,SKIP
R1
R3,R1
In this example, destination working register R1 contains the value 05H which is less than the
contents of the source working register R2 (0AH). The statement "CP R1,R2" generates C = "1"
and the JP instruction does not jump to the SKIP location. After the statement "LD R3,R1"
executes, the value 06H remains in working register R3.
6-18
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
DEC — Decrement
DEC
dst
Operation:
dst ¨ dst – 1
The contents of the destination operand are decremented by one.
Flags:
C:
Z:
S:
V:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if result is negative; cleared otherwise.
Set if arithmetic overflow occurred, that is, dst value is –128(80H) and result value is
+127(7FH); cleared otherwise.
Unaffected.
Unaffected.
D:
H:
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
00
R
4
01
IR
Given: R1 = 03H and register 03H = 10H:
DEC
DEC
R1
@R1
→
→
R1 = 02H
Register 03H = 0FH
In the first example, if working register R1 contains the value 03H, the statement "DEC R1"
decrements the hexadecimal value by one, leaving the value 02H. In the second example, the
statement "DEC @R1" decrements the value 10H contained in the destination register 03H by one,
leaving the value 0FH.
6-19
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
DI — Disable Interrupts
DI
Operation:
SYM (2) ¨ 0
Bit zero of the system mode register, SYM.2, is cleared to "0", globally disabling all interrupt
processing. Interrupt requests will continue to set their respective interrupt pending bits, but the CPU
will not service them while interrupt processing is disabled.
Flags:
No flags are affected.
Format:
opc
Example:
Bytes
Cycles
Opcode
(Hex)
1
4
8F
Given: SYM = 04H:
DI
If the value of the SYM register is 04H, the statement "DI" leaves the new value 00H in the register
and clears SYM.2 to "0", disabling interrupt processing.
6-20
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
EI — Enable Interrupts
EI
Operation:
SYM (2) ¨ 1
An EI instruction sets bit 2 of the system mode register, SYM.2 to "1". This allows interrupts to be
serviced as they occur. If an interrupt's pending bit was set while interrupt processing was disabled
(by executing a DI instruction), it will be serviced when you execute the EI instruction.
Flags:
No flags are affected.
Format:
opc
Example:
Bytes
Cycles
Opcode
(Hex)
1
4
9F
Given: SYM = 00H:
EI
If the SYM register contains the value 00H, that is, if interrupts are currently disabled, the statement
"EI" sets the SYM register to 04H, enabling all interrupts (SYM.2 is the enable bit for global interrupt
processing).
6-21
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
IDLE — Idle Operation
IDLE
Operation:
The IDLE instruction stops the CPU clock while allowing system clock oscillation to continue. Idle
mode can be released by an interrupt request (IRQ) or an external reset operation.
Flags:
No flags are affected.
Format:
opc
Example:
The instruction
IDLE
stops the CPU clock but not the system clock.
6-22
Bytes
Cycles
Opcode
(Hex)
1
4
6F
Addr Mode
dst
src
–
–
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
INC — Increment
INC
dst
Operation:
dst ¨ dst + 1
The contents of the destination operand are incremented by one.
Flags:
C:
Z:
S:
V:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if the result is negative; cleared otherwise.
Set if arithmetic overflow occurred, that is dst value is +127(7FH) and result is –128(80H);
cleared otherwise.
Unaffected.
Unaffected.
D:
H:
Format:
dst | opc
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
1
4
rE
r
r = 0 to F
opc
Examples:
dst
2
4
20
R
4
21
IR
Given: R0 = 1BH, register 00H = 0CH, and register 1BH = 0FH:
INC
INC
INC
R0
00H
@R0
→
→
→
R0 = 1CH
Register 00H = 0DH
R0 = 1BH, register 01H = 10H
In the first example, if destination working register R0 contains the value 1BH, the statement "INC
R0" leaves the value 1CH in that same register.
The next example shows the effect an INC instruction has on register 00H, assuming that it contains
the value 0CH.
In the third example, INC is used in Indirect Register (IR) addressing mode to increment the value of
register 1BH from 0FH to 10H.
6-23
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
IRET — Interrupt Return
IRET
IRET
Operation:
FLAGS ¨ @SP
SP ¨ SP + 1
PC ¨ @SP
SP ¨ SP + 2
SYM(2) ¨ 1
This instruction is used at the end of an interrupt service routine. It restores the flag register and the
program counter. It also re-enables global interrupts.
Flags:
All flags are restored to their original settings (that is, the settings before the interrupt occurred).
Format:
6-24
IRET
(Normal)
Bytes
Cycles
Opcode
(Hex)
opc
1
6
BF
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
JP — Jump
JP
cc,dst
(Conditional)
JP
dst
(Unconditional)
Operation:
If cc is true, PC ¨ dst
The conditional JUMP instruction transfers program control to the destination address if the condition
specified by the condition code (cc) is true; otherwise, the instruction following the JP instruction is
executed. The unconditional JP simply replaces the contents of the PC with the contents of the
specified register pair. Control then passes to the statement addressed by the PC.
Flags:
No flags are affected.
Format: (1)
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
3
8 (3)
ccD
DA
(2)
cc | opc
dst
cc = 0 to F
opc
dst
2
8
30
IRR
NOTES:
1. The 3-byte format is used for a conditional jump and the 2 -byte format for an unconditional jump.
2. In the first byte of the three-byte instruction format (conditional jump), the condition code and the opcode are both four
bits.
Examples:
Given: The carry flag (C) = "1", register 00 = 01H, and register 01 = 20H:
JP
JP
C,LABEL_W
@00H
→
→
LABEL_W = 1000H, PC = 1000H
PC = 0120H
The first example shows a conditional JP. Assuming that the carry flag is set to "1", the statement
"JP C,LABEL_W" replaces the contents of the PC with the value 1000H and transfers control to
that location. Had the carry flag not been set, control would then have passed to the statement
immediately following the JP instruction.
The second example shows an unconditional JP. The statement "JP @00" replaces the contents of
the PC with the contents of the register pair 00H and 01H, leaving the value 0120H.
6-25
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
JR — Jump Relative
JR
cc,dst
Operation:
If cc is true, PC ¨ PC +
dst
If the condition specified by the condition code (cc) is true, the relative address is added to the
program counter and control passes to the statement whose address is now in the program counter;
otherwise, the instruction following the JR instruction is executed (See list of condition codes).
The range of the relative address is +127, –128, and the original value of the program counter is
taken to be the address of the first instruction byte following the JR statement.
Flags:
No flags are affected.
Format:
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
6 (2)
ccB
RA
(1)
cc | opc
dst
cc = 0 to F
NOTE:
Example:
In the first byte of the two-byte instruction format, the condition code and the opcode are each four
bits.
Given: The carry flag = "1" and LABEL_X = 1FF7H:
JR
C,LABEL_X
→
PC = 1FF7H
If the carry flag is set (that is, if the condition code is true), the statement "JR C,LABEL_X" will
pass control to the statement whose address is now in the PC. Otherwise, the program instruction
following the JR would be executed.
6-26
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
LD — Load
LD
dst,src
Operation:
dst ¨ src
The contents of the source are loaded into the destination. The source's contents are unaffected.
Flags:
No flags are affected.
Format:
dst | opc
src | opc
src
dst
Bytes
Cycles
Opcode
(Hex)
2
4
rC
r
IM
4
r8
r
R
4
r9
R
r
2
Addr Mode
dst
src
r = 0 to F
opc
opc
opc
dst | src
src
dst
2
dst
src
3
3
4
C7
r
lr
4
D7
Ir
r
6
E4
R
R
6
E5
R
IR
6
E6
R
IM
6
D6
IR
IM
opc
src
dst
3
6
F5
IR
R
opc
dst | src
x
3
6
87
r
x [r]
opc
src | dst
x
3
6
97
x [r]
r
6-27
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
LD — Load
LD
(Continued)
Examples:
Given: R0 = 01H, R1 = 0AH, register 00H = 01H, register 01H = 20H,
register 02H = 02H, LOOP = 30H, and register 3AH = 0FFH:
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
6-28
R0,#10H
→
R0,01H
→
01H,R0
→
R1,@R0
→
@R0,R1
→
00H,01H
→
02H,@00H
→
00H,#0AH
→
@00H,#10H →
@00H,02H
→
R0,#LOOP[R1]→
#LOOP[R0],R1→
R0 = 10H
R0 = 20H, register 01H = 20H
Register 01H = 01H, R0 = 01H
R1 = 20H, R0 = 01H
R0 = 01H, R1 = 0AH, register 01H = 0AH
Register 00H = 20H, register 01H = 20H
Register 02H = 20H, register 00H = 01H
Register 00H = 0AH
Register 00H = 01H, register 01H = 10H
Register 00H = 01H, register 01H = 02, register 02H = 02H
R0 = 0FFH, R1 = 0AH
Register 31H = 0AH, R0 = 01H, R1 = 0AH
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
LDC/LDE — Load Memory
LDC/LDE
dst,src
Operation:
dst ¨ src
This instruction loads a byte from program or data memory into a working register or vice-versa. The
source values are unaffected. LDC refers to program memory and LDE to data memory. The
assembler makes 'Irr' or 'rr' values an even number for program memory and an odd number for data
memory.
Flags:
No flags are affected.
Format:
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
src
1.
opc
dst | src
2
10
C3
r
Irr
2.
opc
src | dst
2
10
D3
Irr
r
3.
opc
dst | src
XS
3
12
E7
r
XS [rr]
4.
opc
src | dst
XS
3
12
F7
XS [rr]
r
5.
opc
dst | src
XLL
XLH
4
14
A7
r
XL [rr]
6.
opc
src | dst
XLL
XLH
4
14
B7
XL [rr]
r
7.
opc
dst | 0000
DAL
DAH
4
14
A7
r
DA
8.
opc
src | 0000
DAL
DAH
4
14
B7
DA
r
9.
opc
dst | 0001
DAL
DAH
4
14
A7
r
DA
10.
opc
src | 0001
DAL
DAH
4
14
B7
DA
r
NOTES:
1. The source (src) or working register pair [rr] for formats 5 and 6 cannot use register pair 0 –1.
2. For formats 3 and 4, the destination addres s 'XS [rr]' and the source address 'XS [rr]' are each one byte.
3. For formats 5 and 6, the destination address 'XL [rr] and the source address 'XL [rr]' are each two bytes.
4. The DA and r source values for formats 7 and 8 are used to address program memory; the second set of values, used
in formats 9 and 10, are used to address data memory.
6-29
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
LDC/LDE — Load Memory
LDC/LDE
(Continued)
Examples:
Given: R0 = 11H, R1 = 34H, R2 = 01H, R3 = 04H, R4 = 00H, R5 = 60H; Program memory locations
0061 = AAH, 0103H = 4FH, 0104H = 1A, 0105H = 6DH, and 1104H = 88H. External data memory
locations 0061H = BBH, 0103H = 5FH, 0104H = 2AH, 0105H = 7DH, and
1104H = 98H:
LDC
R0,@RR2
LDE
R0,@RR2
LDC *
@RR2,R0
LDE
@RR2,R0
LDC
R0,#01H[RR4]
LDE
R0,#01H[RR4]
LDC (note)
#01H[RR4],R0
LDE
#01H[RR4],R0
LDC
R0,#1000H[RR2]
LDE
R0,#1000H[RR2]
LDC
R0,1104H
LDE
R0,1104H
LDC (note)
1105H,R0
LDE
1105H,R0
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
R0 ¨ contents of program memory location 0104H
R0 = 1AH, R2 = 01H, R3 = 04H
R0 ¨ contents of external data memory location 0104H
R0 = 2AH, R2 = 01H, R3 = 04H
11H (contents of R0) is loaded into program memory
location 0104H (RR2),
working registers R0, R2, R3 Æ no change
11H (contents of R0) is loaded into external data memory
location 0104H (RR2),
working registers R0, R2, R3 Æ no change
R0 ¨ contents of program memory location 0061H
(01H + RR4),
R0 = AAH, R2 = 00H, R3 = 60H
R0 ¨ contents of external data memory location 0061H
(01H + RR4), R0 = BBH, R4 = 00H, R5 = 60H
11H (contents of R0) is loaded into program memory
location 0061H (01H + 0060H)
11H (contents of R0) is loaded into external data memory
location 0061H (01H + 0060H)
R0 ¨ contents of program memory location 1104H
(1000H + 0104H), R0 = 88H, R2 = 01H, R3 = 04H
R0 ¨ contents of external data memory location 1104H
(1000H + 0104H), R0 = 98H, R2 = 01H, R3 = 04H
R0 ¨ contents of program memory location 1104H,
R0 = 88H
R0 ¨ contents of external data memory location 1104H,
R0 = 98H
11H (contents of R0) is loaded into program memory
location 1105H, (1105H) ¨ 11H
11H (contents of R0) is loaded into external data memory
location 1105H, (1105H) ¨ 11H
NOTE: These instructions are not supported by masked ROM type devices.
6-30
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
LDCD/LDED — Load Memory and Decrement
LDCD/LDED
dst,src
Operation:
dst ¨ src
rr ¨ rr – 1
These instructions are used for user stacks or block transfers of data from program or data memory
to the register file. The address of the memory location is specified by a working register pair. The
contents of the source location are loaded into the destination location. The memory address is then
decremented. The contents of the source are unaffected.
LDCD references program memory and LDED references external data memory. The assembler
makes ‘Irr’ an even number for program memory and an odd number for data memory.
Flags:
No flags are affected.
Format:
opc
Examples:
dst | src
Bytes
Cycles
Opcode
(Hex)
2
10
E2
Addr Mode
dst
src
r
Irr
Given: R6 = 10H, R7 = 33H, R8 = 12H, program memory location 1033H = 0CDH, and
external data memory location 1033H = 0DDH:
LDCD
LDED
R8,@RR6
R8,@RR6
;
;
;
;
;
;
0CDH (contents of program memory location 1033H) is
loaded into R8 and RR6 is decremented by one
R8 = 0CDH, R6 = 10H, R7 = 32H (RR6 ← RR6 - 1)
0DDH (contents of data memory location 1033H) is
loaded into R8 and RR6 is decremented by one
(RR6 ← RR6 - 1) R8 = 0DDH, R6 = 10H, R7 = 32H
6-31
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
LDCI/LDEI — Load Memory and Increment
LDCI/LDEI
dst,src
Operation:
dst ¨ src
rr ¨ rr + 1
These instructions are used for user stacks or block transfers of data from program or data memory
to the register file. The address of the memory location is specified by a working register pair. The
contents of the source location are loaded into the destination location. The memory address is then
incremented automatically. The contents of the source are unaffected.
LDCI refers to program memory and LDEI refers to external data memory. The assembler makes 'Irr'
even for program memory and odd for data memory.
Flags:
No flags are affected.
Format:
opc
Examples:
6-32
dst | src
Bytes
Cycles
Opcode
(Hex)
2
10
E3
Addr Mode
dst
src
r
Irr
Given: R6 = 10H, R7 = 33H, R8 = 12H, program memory locations 1033H = 0CDH and
1034H = 0C5H; external data memory locations 1033H = 0DDH and 1034H = 0D5H:
LDCI
R8,@RR6
LDEI
R8,@RR6
;
;
;
;
;
;
0CDH (contents of program memory location 1033H) is
loaded into R8 and RR6 is incremented by one
(RR6 ¨ RR6 + 1) R8 = 0CDH, R6 = 10H, R7 = 34H
0DDH (contents of data memory location 1033H) is
loaded into R8 and RR6 is incremented by one
(RR6 ¨ RR6 + 1) R8 = 0DDH, R6 = 10H, R7 = 34H
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
NOP — No Operation
NOP
Operation:
No action is performed when the CPU executes this instruction. Typically, one or more NOPs are
executed in sequence in order to effect a timing delay of variable duration.
Flags:
No flags are affected.
Format:
opc
Example:
Bytes
Cycles
Opcode
(Hex)
1
4
FF
When the instruction
NOP
is encountered in a program, no operation occurs. Instead, there is a delay in instruction execution
time.
6-33
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
OR — Logical OR
OR
dst,src
Operation:
dst ¨ dst OR src
The source operand is logically ORed with the destination operand and the result is stored in the
destination. The contents of the source are unaffected. The OR operation results in a "1" being
stored whenever either of the corresponding bits in the two operands is a "1"; otherwise a "0" is
stored.
Flags:
C:
Z:
S:
V:
D:
H:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Always cleared to "0".
Unaffected.
Unaffected.
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
42
r
r
6
43
r
lr
6
44
R
R
6
45
R
IR
6
46
R
IM
3
3
Addr Mode
dst
src
Given: R0 = 15H, R1 = 2AH, R2 = 01H, register 00H = 08H, register 01H = 37H, and register 08H
= 8AH:
OR
OR
OR
OR
OR
R0,R1
R0,@R2
00H,01H
01H,@00H
00H,#02H
→
→
→
→
→
R0 = 3FH, R1 = 2AH
R0 = 37H, R2 = 01H, register 01H = 37H
Register 00H = 3FH, register 01H = 37H
Register 00H = 08H, register 01H = 0BFH
Register 00H = 0AH
In the first example, if working register R0 contains the value 15H and register R1 the value 2AH, the
statement "OR R0,R1" logical-ORs the R0 and R1 register contents and stores the result (3FH) in
destination register R0.
The other examples show the use of the logical OR instruction with the various addressing modes
and formats.
6-34
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
POP — Pop From Stack
POP
dst
Operation:
dst ¨ @SP
SP ¨ SP + 1
The contents of the location addressed by the stack pointer are loaded into the destination. The
stack pointer is then incremented by one.
Flags:
No flags affected.
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
8
50
R
8
51
IR
Given: Register 00H = 01H, register 01H = 1BH, SP (0D9H) = 0BBH, and stack register
0BBH = 55H:
POP
POP
00H
@00H
→
→
Register 00H = 55H, SP = 0BCH
Register 00H = 01H, register 01H = 55H, SP = 0BCH
In the first example, general register 00H contains the value 01H. The statement "POP 00H" loads
the contents of location 0BBH (55H) into destination register 00H and then increments the stack
pointer by one. Register 00H then contains the value 55H and the SP points to location 0BCH.
6-35
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
PUSH — Push To Stack
PUSH
src
Operation:
SP ¨ SP – 1
@SP ¨ src
A PUSH instruction decrements the stack pointer value and loads the contents of the source (src)
into the location addressed by the decremented stack pointer. The operation then adds the new
value to the top of the stack.
Flags:
No flags are affected.
Format:
opc
Examples:
src
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
8
70
R
8
71
IR
Given: Register 40H = 4FH, register 4FH = 0AAH, SP = 0C0H:
PUSH
40H
→
PUSH
@40H
→
Register 40H = 4FH, stack register 0BFH = 4FH,
SP = 0BFH
Register 40H = 4FH, register 4FH = 0AAH, stack register
0BFH = 0AAH, SP = 0BFH
In the first example, if the stack pointer contains the value 0C0H, and general register 40H the value
4FH, the statement "PUSH 40H" decrements the stack pointer from 0C0 to 0BFH. It then loads the
contents of register 40H into location 0BFH. Register 0BFH then contains the value 4FH and SP
points to location 0BFH.
6-36
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
RCF — Reset Carry Flag
RCF
RCF
Operation:
C ¨ 0
The carry flag is cleared to logic zero, regardless of its previous value.
Flags:
C:
Cleared to "0".
No other flags are affected.
Format:
opc
Example:
Bytes
Cycles
Opcode
(Hex)
1
4
CF
Given: C = "1" or "0":
The instruction RCF clears the carry flag (C) to logic zero.
6-37
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
RET— Return
RET
Operation:
PC ¨ @SP
SP ¨ SP + 2
The RET instruction is normally used to return to the previously executing procedure at the end of a
procedure entered by a CALL instruction. The contents of the location addressed by the stack
pointer are popped into the program counter. The next statement that is executed is the one that is
addressed by the new program counter value.
Flags:
No flags are affected.
Format:
opc
Example:
Bytes
Cycles
Opcode
(Hex)
1
8
AF
Given: SP = 0BCH, (SP) = 101AH, and PC = 1234:
RET
→
PC = 101AH, SP = 0BEH
The statement "RET" pops the contents of stack pointer location 0BCH (10H) into the high byte of
the program counter. The stack pointer then pops the value in location 0BDH (1AH) into the PC's low
byte and the instruction at location 101AH is executed. The stack pointer now points to memory
location 0BEH.
6-38
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
RL — Rotate Left
RL
dst
Operation:
C ¨ dst (7)
dst (0) ¨ dst (7)
dst (n + 1) ¨ dst (n), n = 0–6
The contents of the destination operand are rotated left one bit position. The initial value of bit 7 is
moved to the bit zero (LSB) position and also replaces the carry flag.
7
0
C
Flags:
C:
Z:
S:
V:
D:
H:
Set if the bit rotated from the most significant bit position (bit 7) was "1".
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Set if arithmetic overflow occurred, that is, if the sign of the destination changed during
rotation; cleared otherwise.
Unaffected.
Unaffected.
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
90
R
4
91
IR
Given: Register 00H = 0AAH, register 01H = 02H and register 02H = 17H:
RL
RL
00H
@01H
→
→
Register 00H = 55H, C = "1"
Register 01H = 02H, register 02H = 2EH, C = "0"
In the first example, if general register 00H contains the value 0AAH (10101010B), the statement "RL
00H" rotates the 0AAH value left one bit position, leaving the new value 55H (01010101B) and setting
the carry and overflow flags.
6-39
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
RLC — Rotate Left Through Carry
RLC
dst
Operation:
dst (0) ¨ C
C ¨ dst (7)
dst (n + 1) ¨ dst (n), n = 0–6
The contents of the destination operand with the carry flag are rotated left one bit position. The initial
value of bit 7 replaces the carry flag (C); the initial value of the carry flag replaces bit zero.
7
0
C
Flags:
C:
Z:
S:
V:
Set if the bit rotated from the most significant bit position (bit 7) was "1".
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Set if arithmetic overflow occurred, that is, if the sign of the destination changed during
rotation; cleared otherwise.
Unaffected.
Unaffected.
D:
H:
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
10
R
4
11
IR
Given: Register 00H = 0AAH, register 01H = 02H, and register 02H = 17H, C = "0":
RLC
RLC
00H
@01H
→
→
Register 00H = 54H, C = "1"
Register 01H = 02H, register 02H = 2EH, C = "0"
In the first example, if general register 00H has the value 0AAH (10101010B), the statement "RLC
00H" rotates 0AAH one bit position to the left. The initial value of bit 7 sets the carry flag and the
initial value of the C flag replaces bit zero of register 00H, leaving the value 55H (01010101B). The
MSB of register 00H resets the carry flag to "1" and sets the overflow flag.
6-40
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
RR — Rotate Right
RR
dst
Operation:
C ¨ dst (0)
dst (7) ¨ dst (0)
dst (n) ¨ dst (n + 1), n = 0–6
The contents of the destination operand are rotated right one bit position. The initial value of bit zero
(LSB) is moved to bit 7 (MSB) and also replaces the carry flag (C).
7
0
C
Flags:
C:
Z:
S:
V:
D:
H:
Set if the bit rotated from the least significant bit position (bit zero) was "1".
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Set if arithmetic overflow occurred, that is, if the sign of the destination changed during
rotation; cleared otherwise.
Unaffected.
Unaffected.
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
E0
R
4
E1
IR
Given: Register 00H = 31H, register 01H = 02H, and register 02H = 17H:
RR
RR
00H
@01H
→
→
Register 00H = 98H, C = "1"
Register 01H = 02H, register 02H = 8BH, C = "1"
In the first example, if general register 00H contains the value 31H (00110001B), the statement "RR
00H" rotates this value one bit position to the right. The initial value of bit zero is moved to bit 7,
leaving the new value 98H (10011000B) in the destination register. The initial bit zero also resets the
C flag to "1" and the sign flag and overflow flag are also set to "1".
6-41
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
RRC — Rotate Right Through Carry
RRC
dst
Operation:
dst (7) ¨ C
C ¨ dst (0)
dst (n) ¨ dst (n + 1), n = 0–6
The contents of the destination operand and the carry flag are rotated right one bit position. The initial
value of bit zero (LSB) replaces the carry flag; the initial value of the carry flag replaces bit 7 (MSB).
7
0
C
Flags:
C:
Z:
S:
V:
D:
H:
Set if the bit rotated from the least significant bit position (bit zero) was "1".
Set if the result is "0" cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Set if arithmetic overflow occurred, that is, if the sign of the destination changed during
rotation; cleared otherwise.
Unaffected.
Unaffected.
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
C0
R
4
C1
IR
Given: Register 00H = 55H, register 01H = 02H, register 02H = 17H, and C = "0":
RRC
RRC
00H
@01H
→
→
Register 00H = 2AH, C = "1"
Register 01H = 02H, register 02H = 0BH, C = "1"
In the first example, if general register 00H contains the value 55H (01010101B), the statement "RRC
00H" rotates this value one bit position to the right. The initial value of bit zero ("1") replaces the carry
flag and the initial value of the C flag ("1") replaces bit 7. This leaves the new value 2AH (00101010B)
in destination register 00H. The sign flag and overflow flag are both cleared to "0".
6-42
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
SBC — Subtract With Carry
SBC
dst,src
Operation:
dst ¨ dst – src – c
The source operand, along with the current value of the carry flag, is subtracted from the destination
operand and the result is stored in the destination. The contents of the source are unaffected.
Subtraction is performed by adding the two's-complement of the source operand to the destination
operand. In multiple precision arithmetic, this instruction permits the carry ("borrow") from the
subtraction of the low-order operands to be subtracted from the subtraction of high-order operands.
Flags:
C:
Z:
S:
V:
Set if a borrow occurred (src > dst); cleared otherwise.
Set if the result is "0"; cleared otherwise.
Set if the result is negative; cleared otherwise.
Set if arithmetic overflow occurred, that is, if the operands were of opposite sign and the sign
if the result is the same as the sign of the source; cleared otherwise.
Always set to "1".
Cleared if there is a carry from the most significant bit of the low-order four bits of the result;
set otherwise, indicating a "borrow".
D:
H:
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
32
r
r
6
33
r
lr
6
34
R
R
6
35
R
IR
6
36
R
IM
3
3
Addr Mode
dst
src
Given: R1 = 10H, R2 = 03H, C = "1", register 01H = 20H, register 02H = 03H, and register
03H = 0AH:
SBC
SBC
SBC
SBC
SBC
R1,R2
R1,@R2
01H,02H
01H,@02H
01H,#8AH
→
→
→
→
→
R1 = 0CH, R2 = 03H
R1 = 05H, R2 = 03H, register 03H = 0AH
Register 01H = 1CH, register 02H = 03H
Register 01H = 15H,register 02H = 03H, register 03H = 0AH
Register 01H = 95H; C, S, and V = "1"
In the first example, if working register R1 contains the value 10H and register R2 the value 03H, the
statement "SBC R1,R2" subtracts the source value (03H) and the C flag value ("1") from the
destination (10H) and then stores the result (0CH) in register R1.
6-43
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
SCF — Set Carry Flag
SCF
Operation:
C ¨ 1
The carry flag (C) is set to logic one, regardless of its previous value.
Flags:
C:
Set to "1".
No other flags are affected.
Format:
opc
Example:
The statement
SCF
sets the carry flag to logic one.
6-44
Bytes
Cycles
Opcode
(Hex)
1
4
DF
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
SRA — Shift Right Arithmetic
SRA
dst
Operation:
dst (7) ¨ dst (7)
C ¨ dst (0)
dst (n) ¨ dst (n + 1), n = 0–6
An arithmetic shift-right of one bit position is performed on the destination operand. Bit zero (the
LSB) replaces the carry flag. The value of bit 7 (the sign bit) is unchanged and is shifted into bit
position 6.
7
6
0
C
Flags:
C:
Z:
S:
V:
D:
H:
Set if the bit shifted from the LSB position (bit zero) was "1".
Set if the result is "0"; cleared otherwise.
Set if the result is negative; cleared otherwise.
Always cleared to "0".
Unaffected.
Unaffected.
Format:
opc
Examples:
dst
Bytes
Cycles
Opcode
(Hex)
Addr Mode
dst
2
4
D0
R
4
D1
IR
Given: Register 00H = 9AH, register 02H = 03H, register 03H = 0BCH, and C = "1":
SRA
SRA
00H
@02H
→
→
Register 00H = 0CD, C = "0"
Register 02H = 03H, register 03H = 0DEH, C = "0"
In the first example, if general register 00H contains the value 9AH (10011010B), the statement "SRA
00H" shifts the bit values in register 00H right one bit position. Bit zero ("0") clears the C flag and bit
7 ("1") is then shifted into the bit 6 position (bit 7 remains unchanged). This leaves the value 0CDH
(11001101B) in destination register 00H.
6-45
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
STOP — Stop Operation
STOP
Operation:
The STOP instruction stops both the CPU clock and system clock and causes the microcontroller to
enter Stop mode. During Stop mode, the contents of on-chip CPU registers, peripheral registers, and
I/O port control and data registers are retained. Stop mode can be released by an external reset
operation or External interrupt input. For the reset operation, the RESET pin must be held to Low
level until the required oscillation stabilization interval has elapsed.
Flags:
No flags are affected.
Format:
opc
Example:
The statement
STOP
halts all microcontroller operations.
6-46
Bytes
Cycles
Opcode
(Hex)
1
4
7F
Addr Mode
dst
src
–
–
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
SUB — Subtract
SUB
dst,src
Operation:
dst ¨ dst – src
The source operand is subtracted from the destination operand and the result is stored in the
destination. The contents of the source are unaffected. Subtraction is performed by adding the two's
complement of the source operand to the destination operand.
Flags:
C:
Z:
S:
V:
Set if a "borrow" occurred; cleared otherwise.
Set if the result is "0"; cleared otherwise.
Set if the result is negative; cleared otherwise.
Set if arithmetic overflow occurred, that is, if the operands were of opposite signs and the
sign of the result is of the same as the sign of the source operand; cleared otherwise.
Always set to "1".
Cleared if there is a carry from the most significant bit of the low-order four bits of the result;
set otherwise indicating a "borrow".
D:
H:
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
22
r
r
6
23
r
lr
6
24
R
R
6
25
R
IR
6
26
R
IM
3
3
Addr Mode
dst
src
Given: R1 = 12H, R2 = 03H, register 01H = 21H, register 02H = 03H, register 03H = 0AH:
SUB
SUB
SUB
SUB
SUB
SUB
R1,R2
R1,@R2
01H,02H
01H,@02H
01H,#90H
01H,#65H
→
→
→
→
→
→
R1 = 0FH, R2 = 03H
R1 = 08H, R2 = 03H
Register 01H = 1EH, register 02H = 03H
Register 01H = 17H, register 02H = 03H
Register 01H = 91H; C, S, and V = "1"
Register 01H = 0BCH; C and S = "1", V = "0"
In the first example, if working register R1 contains the value 12H and if register R2 contains the
value 03H, the statement "SUB R1,R2" subtracts the source value (03H) from the destination value
(12H) and stores the result (0FH) in destination register R1.
6-47
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
TCM — Test Complement Under Mask
TCM
dst,src
Operation:
(NOT dst) AND src
This instruction tests selected bits in the destination operand for a logic one value. The bits to be
tested are specified by setting a "1" bit in the corresponding position of the source operand (mask).
The TCM statement complements the destination operand, which is then ANDed with the source
mask. The zero (Z) flag can then be checked to determine the result. The destination and source
operands are unaffected.
Flags:
C:
Z:
S:
V:
D:
H:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Always cleared to "0".
Unaffected.
Unaffected.
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
62
r
r
6
63
r
lr
6
64
R
R
6
65
R
IR
6
66
R
IM
3
3
Addr Mode
dst
src
Given: R0 = 0C7H, R1 = 02H, R2 = 12H, register 00H = 2BH, register 01H = 02H, and register 02H
= 23H:
TCM
TCM
TCM
TCM
R0,R1
R0,@R1
00H,01H
00H,@01H
→
→
→
→
TCM
00H,#34
→
R0 = 0C7H, R1 = 02H, Z = "1"
R0 = 0C7H, R1 = 02H, register 02H = 23H, Z = "0"
Register 00H = 2BH, register 01H = 02H, Z = "1"
Register 00H = 2BH, register 01H = 02H,
register 02H = 23H, Z = "1"
Register 00H = 2BH, Z = "0"
In the first example, if working register R0 contains the value 0C7H (11000111B) and register R1 the
value 02H (00000010B), the statement "TCM R0,R1" tests bit one in the destination register for a
"1" value. Because the mask value corresponds to the test bit, the Z flag is set to logic one and can
be tested to determine the result of the TCM operation.
6-48
S3C94A5/F94A5
SAM88RCRI INSTRUCTION SET
TM — Test Under Mask
TM
dst,src
Operation:
dst AND src
This instruction tests selected bits in the destination operand for a logic zero value. The bits to be
tested are specified by setting a "1" bit in the corresponding position of the source operand (mask),
which is ANDed with the destination operand. The zero (Z) flag can then be checked to determine the
result. The destination and source operands are unaffected.
Flags:
C:
Z:
S:
V:
D:
H:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Always reset to "0".
Unaffected.
Unaffected.
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
72
r
r
6
73
r
lr
6
74
R
R
6
75
R
IR
6
76
R
IM
3
3
Addr Mode
dst
src
Given: R0 = 0C7H, R1 = 02H, R2 = 18H, register 00H = 2BH, register 01H = 02H, and register 02H
= 23H:
TM
TM
TM
TM
R0,R1
R0,@R1
00H,01H
00H,@01H
→
→
→
→
TM
00H,#54H
→
R0 = 0C7H, R1 = 02H, Z = "0"
R0 = 0C7H, R1 = 02H, register 02H = 23H, Z = "0"
Register 00H = 2BH, register 01H = 02H, Z = "0"
Register 00H = 2BH, register 01H = 02H,
register 02H = 23H, Z = "0"
Register 00H = 2BH, Z = "1"
In the first example, if working register R0 contains the value 0C7H (11000111B) and register R1 the
value 02H (00000010B), the statement "TM R0,R1" tests bit one in the destination register for a "0"
value. Because the mask value does not match the test bit, the Z flag is cleared to logic zero and
can be tested to determine the result of the TM operation.
6-49
SAM88RCRI INSTRUCTION SET
S3C94A5/F94A5
XOR — Logical Exclusive OR
XOR
dst,src
Operation:
dst ¨ dst XOR src
The source operand is logically exclusive-ORed with the destination operand and the result is stored
in the destination. The exclusive-OR operation results in a "1" bit being stored whenever the
corresponding bits in the operands are different; otherwise, a "0" bit is stored.
Flags:
C:
Z:
S:
V:
D:
H:
Unaffected.
Set if the result is "0"; cleared otherwise.
Set if the result bit 7 is set; cleared otherwise.
Always reset to "0".
Unaffected.
Unaffected.
Format:
opc
opc
opc
Examples:
dst | src
src
dst
dst
src
Bytes
Cycles
Opcode
(Hex)
2
4
B2
r
r
6
B3
r
lr
6
B4
R
R
6
B5
R
IR
6
B6
R
IM
3
3
Addr Mode
dst
src
Given: R0 = 0C7H, R1 = 02H, R2 = 18H, register 00H = 2BH, register 01H = 02H, and register 02H
= 23H:
XOR
XOR
XOR
XOR
R0,R1
R0,@R1
00H,01H
00H,@01H
→
→
→
→
XOR
00H,#54H
→
R0 = 0C5H, R1 = 02H
R0 = 0E4H, R1 = 02H, register 02H = 23H
Register 00H = 29H, register 01H = 02H
Register 00H = 08H, register 01H = 02H,
register 02H = 23H
Register 00H = 7FH
In the first example, if working register R0 contains the value 0C7H and if register R1 contains the
value 02H, the statement "XOR R0,R1" logically exclusive-ORs the R1 value with the R0 value and
stores the result (0C5H) in the destination register R0.
6-50
S3C94A5/F94A5
7
CLOCK CIRCUITS
CLOCK CIRCUITS
OVERVIEW
The S3C94A5/F94A5 has the oscillator circuit for system clock. There are three methods being oscillation. First, A
method that a crystal, ceramic, or resistor is connected between XIN and XOUT. Second, the name is external RC
oscillator; A resistor is connected between XIN and VDD. Third, the name is internal RC oscillator; XIN and XOUT have
to be disconnected.
SYSTEM CLOCK CIRCUIT
The system clock circuit has the following components:
— Crystal, ceramic resonator, RC oscillation source (main clock only), or an external clock
— Internal or external RC oscillation source
— Oscillator stop and wake-up functions
— Programmable frequency divider for the CPU clock (fxx divided by 1, 2, 8, or 16)
— Clock circuit control register, CLKCON
— STOP control register, STPCON
CPU CLOCK NOTATION
In this document, the following notation is used for descriptions of the CPU clock;
fx: main clock
fxt: sub clock (the fxt is not implemented in the S3C94A5/F94A5)
fxx: selected system clock
7-1
CLOCK CIRCUITS
S3C94A5/F94A5
MAIN OSCILLATOR CIRCUITS
VDD
R
XIN
XIN
XOUT
NC
Figure 7-1. Crystal/Ceramic Oscillator(fx)
Figure 7-4. External RC Oscillator(fx)
XIN
NC
XIN
XOUT
NC
XOUT
Figure 7-2. External Oscillator(fx)
XIN
R
XOUT
Figure 7-3. RC Oscillator(fx)
7-2
XOUT
Figure 7-5. Internal RC Oscillator(fx)
S3C94A5/F94A5
CLOCK CIRCUITS
CLOCK STATUS DURING POWER-DOWN MODES
The two power-down modes, Stop mode and Idle mode, affect the system clock as follows:
— In Stop mode, the main oscillator is halted. Stop mode is released, and the oscillator started, by a reset
operation or an external interrupt. (with RC delay noise filter)
— In Idle mode, the internal clock signal is gated away from the CPU, but continues to be supplied to the interrupt
structure, timer counters and watch timer. Idle mode is released by a reset or by an external or
internal interrupts.
Stop Release
INT
Main-System
Oscillator
Circuit
fX
fXT
Sub-system
Oscillator
Circuit
Selector 1
fXX
Stop
Logic "0"
Stop
Logic "0"
Logic "1"
STOP OSC
inst.
STPCON
1/1
CLKCON.4-.3
1/8-1/4096
Basic Timer
Timer/Counters
Frequency
Dividing
Circuit
Watch Timer
1/2
1/8
SIO
1/16
A/D Converter
Selector 2
CPU
IDLE Instruction
NOTE:
The fxt is not implemented in the S3C94A5/F94A5.
Figure 7-6. System Clock Circuit Diagram
7-3
CLOCK CIRCUITS
S3C94A5/F94A5
SYSTEM CLOCK CONTROL REGISTER (CLKCON)
The system clock control register, CLKCON, is located in address D4H. It is read/write addressable and has the
following functions:
— Oscillator IRQ wake-up function enable/disable
— Oscillator frequency divide-by value
CLKCON register settings control whether or not an external interrupt can be used to trigger a Stop mode release
(This is called the “IRQ wake-up” function). The IRQ “wake-up” enable bit is CLKCON.7.
After a reset, the external interrupt oscillator wake-up function is enabled, the main oscillator is activated, and the
fx/16 (the slowest clock speed) is selected as the CPU clock. If necessary, you can then increase the CPU clock
speed to fx, fx/2, or fx/8 by setting the CLKCON.
System Clock Control Register (CLKCON)
D4H, R/W
MSB
.7
.6
Oscillator IRQ wake-up function bit:
0 = Enable IRQ for main wake-up in
power down mode
1 = Disable IRQ for main wake-up in
power down mode
.5
.4
.3
.2
.1
.0
LSB
Not used for S3C94A5/F94A5 (must keep always "0")
Divide-by selection bits for
CPU clock frequency:
00 = fxx/16
01 = fxx/8
10 = fXx/2
11 = fxx
Not used for S3C94A5/F94A5 (must keep always "0")
Figure 7-7. System Clock Control Register (CLKCON)
7-4
S3C94A5/F94A5
CLOCK CIRCUITS
STOP CONTROL REGISTER (STPCON)
The STOP control register, STPCON, is located in address E0H. It is read/write addressable and has the following
functions:
— Enable/Disable STOP instruction
After a reset, the STOP instruction is disabled, because the value of STPCON is "other values".
If necessary, you can use the STOP instruction by setting the value of STPCON to "10100101B".
Stop Control Register (STPCON)
E0H, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
STOP control bits:
10100101 = Enable STOP instruction
Other values = Disable STOP instruction
Figure 7-8. STOP Control Register (STPCON)
F
PROGRAMMING TIP — How to Use Stop Instruction
This example shows how to go STOP mode when a main clock is selected as the system clock.
LD
STOP
NOP
NOP
NOP
LD
STPCON,#10100101B
STPCON,#00000000B
; Enable STOP instruction
; Enter STOP mode
; Release STOP mode
; Disable STOP instruction
7-5
S3C94A5/F94A5
8
RESET and POWER-DOWN
RESET and POWER-DOWN
SYSTEM RESET
OVERVIEW
During a power-on reset, the voltage at VDD goes to High level and the nRESET pin is forced to Low level. The
nRESET signal is input through a schmitt trigger circuit where it is then synchronized with the CPU clock. This
procedure brings S3C94A5/F94A5 into a known operating status.
To allow time for internal CPU clock oscillation to stabilize, the nRESET pin must be held to Low level for a minimum
time interval after the power supply comes within tolerance. The minimum required oscillation stabilization time for a
reset operation is 1 millisecond.
Whenever a reset occurs during normal operation (that is, when both VDD and nRESET are High level), the nRESET
pin is forced Low and the reset operation starts. All system and peripheral control registers are then reset to their
default hardware values (see Table 8-1).
In summary, the following sequence of events occurs during a reset operation:
— All interrupts are disabled.
— The watchdog function (basic timer) is enabled.
— Port1–5 are set to input mode and all pull-up resistors are disabled for the I/O port pin circuits.
— Peripheral control and data registers are disabled and reset to their default hardware values.
— The program counter (PC) is loaded with the program reset address in the ROM, 0100H.
— When the programmed oscillation stabilization time interval has elapsed, the instruction stored in ROM location
0100H (and 0101H) is fetched and executed.
NOTE
To program the duration of the oscillation stabilization interval, you make the appropriate settings to the
basic timer control register, BTCON, before entering Stop mode. Also, if you do not want to use the basic
timer watchdog function (which causes a system reset if a basic timer counter overflow occurs), you can
disable it by writing '1010B' to the upper nibble of BTCON.
8-1
RESET and POWER-DOWN
S3C94A5/F94A5
POWER-DOWN MODES
STOP MODE
Stop mode is invoked by the instruction STOP. In Stop mode, the operation of the CPU and all peripherals is halted.
That is, the on-chip main oscillator stops and the supply current is reduced to less than 2µA. All system functions
stop when the clock "freezes", but data stored in the internal register file is retained. Stop mode can be released in
one of two ways: by a reset or by external interrupts.
Example:
LD
STOP
NOP
NOP
NOP
LD
STPCON,#10100101B
STPCON,#00000000B
NOTES
1.
2.
3.
Do not use stop mode if you are using an external clock source because XIN input must be restricted
internally to VSS to reduce current leakage.
In application programs, a STOP instruction must be immediately followed by at least three NOP
instructions. This ensures an adequate time interval for the clock to stabilize before the next
instruction is executed. If three or more NOP instructions are not used after STOP instruction,
leakage current could be flown because of the floating state in the internal bus.
To enable/disable STOP instruction, the STPCON register should be written with 10100101B/other
values before/after stop instruction.
Using nRESET to Release Stop Mode
Stop mode is released when the nRESET signal goes active (Low level): all system and peripheral control registers
are reset to their default hardware values and the contents of all data registers are retained. When the programmed
oscillation stabilization interval has elapsed, the CPU starts the system initialization routine by fetching the program
instruction stored in ROM location 0100H.
Using an External Interrupt to Release Stop Mode
External interrupts can be used to release stop mode. For the S3C94A5 microcontroller, we recommend using the
INT interrupt, P1, P3, P4.7, and P5.0.
8-2
S3C94A5/F94A5
RESET and POWER-DOWN
IDLE MODE
Idle mode is invoked by the instruction IDLE (opcode 6FH). In Idle mode, CPU operations are halted while some
peripherals remain active. During Idle mode, the internal clock signal is gated away from the CPU and from all but
the following peripherals, which remain active:
— Interrupt logic
— Basic timer
— Timers
— Watch timer
I/O port pins retain the mode (input or output) they had at the time Idle mode was entered.
Idle Mode Release
You can release Idle mode in one of two ways:
1.
Execute a reset. All system and peripheral control registers are reset to their default values and the contents of
all data registers are retained. The reset automatically selects the slowest clock (1/16) because of the hardware
reset value for the CLKCON register. If interrupts are masked, a reset is the only way to release idle mode.
2.
Activate any enabled interrupt causing idle mode to be released. When you use an interrupt to release Idle
mode, the 2-bit CLKCON.4/CLKCON.3 value remains unchanged, and the currently selected clock value is
used. The interrupt is then serviced. When the return-from-interrupt condition (IRET) occurs, the instruction
immediately following the one which initiated Idle mode is executed.
8-3
RESET and POWER-DOWN
S3C94A5/F94A5
HARDWARE RESET VALUES
Table 8-1 list the values for CPU and system registers, peripheral control registers, and peripheral data registers
following a RESET operation in normal operating mode. The following notation is used in these table to represent
specific RESET values:
— A "1" or a "0" shows the RESET bit value as logic one or logic zero, respectively.
— An 'x' means that the bit value is undefined following RESET.
— A dash ('–') means that the bit is either not used or not mapped.
Table 8-1. Register Values after RESET
Register Name
Mnemonic
Address
Dec
Hex
Bit Values after RESET
7
6
5
4
3
2
1
0
Locations B0H — B3H are not mapped
Timer 0 control register
T0CON
196
B4H
0
0
0
0
0
0
0
0
Timer 0 data register (high byte)
T0DATAH
197
B5H
1
1
1
1
1
1
1
1
Timer 0 data register (low byte)
T0DATAL
198
B6H
1
1
1
1
1
1
1
1
Timer 0 counter (high byte)
T0CNTH
199
B7H
0
0
0
0
0
0
0
0
Timer 0 counter (low byte)
T0CNTL
200
B8H
0
0
0
0
0
0
0
0
Timer 1 control resistor
T1CON
201
B9H
0
0
0
0
0
0
0
0
Timer 1 data register (high byte)
T1DATAH
202
BAH
1
1
1
1
1
1
1
1
Timer 1 data register (low byte)
T1DATAL
203
BBH
1
1
1
1
1
1
1
1
Timer 1 counter (high byte)
T1CNTH
204
BCH
0
0
0
0
0
0
0
0
Timer 1 counter (low byte)
T1CNTL
205
BDH
0
0
0
0
0
0
0
0
Timer 2 control register
T2CON
206
BEH
0
0
0
0
0
0
0
0
Timer 2 data register
T2DATA
207
BFH
1
1
1
1
1
1
1
1
T2CNT
208
D0H
0
0
0
0
0
0
0
0
ADCON
209
D1H
0
0
0
0
0
0
0
0
A/D converter data register (high byte)
ADDATAH
210
D2H
X
X
X
X
X
X
X
X
A/D converter data register (low byte)
ADDATAL
211
D3H
–
–
–
–
–
–
X
X
System clock control register
CLKCON
212
D4H
0
0
0
0
0
0
0
0
FLAGS
213
D5H
X
X
X
X
–
–
–
–
Interrupt pending register 1
INTPND1
214
D6H
–
0
0
0
0
0
0
0
Interrupt pending register 2
INTPND2
215
D7H
0
0
0
0
0
0
0
0
Interrupt pending register 3
INTPND3
216
D8H
0
0
0
0
0
0
0
0
SP
217
D9H
X
X
X
X
X
X
X
X
WTCON
218
DAH
–
0
0
0
0
0
0
–
Timer 2 counter
A/D converter control register
System flags register
Stack pointer
Watch timer control register
Locations DBH is not mapped
8-4
S3C94A5/F94A5
RESET and POWER-DOWN
Table 8-1. Register Values after RESET (Continued)
Register Name
Mnemonic
Address
Bit Values after RESET
Dec
Hex
7
6
5
4
3
2
1
0
Basic timer control register
BTCON
220
DCH
0
0
0
0
0
0
0
0
Basic timer counter
BTCNT
221
DDH
0
0
0
0
0
0
0
0
Location DEH is not mapped
System mode register
SYM
223
DFH
–
–
–
–
0
0
0
0
STOP control register
STPCON
224
E0H
0
0
0
0
0
0
0
0
SIO control register
SIOCON
225
E1H
0
0
0
0
0
0
0
–
SIO data register
SIODATA
226
E2H
0
0
0
0
0
0
0
0
SIOPS
227
E3H
0
0
0
0
0
0
0
0
Port 1 data register
P1
228
E4H
0
0
0
0
0
0
0
0
Port 2 data register
P2
229
E5H
0
0
0
0
0
0
0
0
Port 3 data register
P3
230
E6H
0
0
0
0
0
0
0
0
Port 4 data register
P4
231
E7H
0
0
0
0
0
0
0
0
Port 5 data register
P5
232
E8H
0
0
0
0
0
0
0
0
SIO prescaler register
Location E9H is not mapped
Port 1 control register (high byte)
P1CONH
234
EAH
–
–
0
0
0
0
0
0
Port 1 control register (low byte)
P1CONL
235
EBH
0
0
0
0
0
0
0
0
P1INT
236
ECH
–
0
0
0
0
0
0
0
Port 1 interrupt edge selection register
(high byte)
P1EDGEH
237
EDH
–
–
0
0
0
0
0
0
Port 1 interrupt edge selection register
(low byte)
P1EDGEL
238
EEH
0
0
0
0
0
0
0
0
Port 2 control register (high byte)
P2CONH
239
EFH
–
–
–
–
0
0
0
0
Port 2 control register (low byte)
P2CONL
240
F0H
0
0
0
0
0
0
0
0
P2PUR
241
F1H
–
–
0
0
0
0
0
0
Port 3 control register (high byte)
P3CONH
242
F2H
–
0
0
0
0
0
0
0
Port 3 control register (low byte)
P3CONL
243
F3H
0
0
0
0
0
0
0
0
P3PUR
244
F4H
–
–
0
0
0
0
0
0
P3INT
245
F5H
–
–
0
0
0
0
0
0
Port 3 interrupt edge selection register
(high byte)
P3EDGEH
246
F6H
–
–
–
–
0
0
0
0
Port 3 interrupt edge selection register
(low byte)
P3EDGEL
247
F7H
0
0
0
0
0
0
0
0
Port 4 control register (high byte)
P4CONH
248
F8H
–
–
–
–
0
0
0
0
Port 4 control register (middle byte)
P4CONM
249
F9H
0
0
0
0
0
0
0
0
Port 1 interrupt control register
Port 2 pull-up control register
Port 3 pull-up control register
Port 3 interrupt control register
8-5
RESET and POWER-DOWN
S3C94A5/F94A5
Table 8-1. Register Values after RESET (Continued)
Register Name
Mnemonic
Address
Bit Values after RESET
Dec
Hex
7
6
5
4
3
2
1
0
Port 4 control register (low byte)
P4CONL
250
FAH
–
–
0
0
0
0
0
0
Port 4 and 5 interrupt control register
P4n5INT
251
FBH
–
–
0
0
0
0
0
0
Port 4 pull-up control register
P4PUR
252
FCH
0
0
0
0
0
0
0
0
Port 5 control register (high byte)
P5CONH
253
FDH
0
0
0
0
0
0
0
0
Port 5 control register (low byte)
P5CONL
254
FEH
–
0
0
0
0
0
0
0
Location FFH is not mapped.
8-6
S3C94A5/F94A5
9
I/O PORTS
I/O PORTS
OVERVIEW
The S3C94A5/F94A5 microcontroller has five bit-programmable I/O ports, P1–P5. Port 1 and port 5 are 7-bit ports,
port 2 and port 3 are 6-bit ports and port 4 is 8-bit ports. This gives a total of 34 I/O pins. Each port can be flexibly
configured to meet application design requirements.
The CPU accesses ports by directly writing or reading port registers. No special I/O instructions are required. All
ports of the S3C94A5/F94A5 can be configured to input or output mode.
Table 9-1 gives you a general overview of S3C94A5/F94A5 I/O port functions.
Table 9-1. S3C94A5 Port Configuration Overview
Port
Configuration Options
1
1-bit programmable I/O port.
Schmitt trigger input or push-pull, open-drain output and software assignable pull-ups.
Alternatively P1 can be used as input for external interrupts INT.
2
1-bit programmable I/O port.
Input or push-pull, open-drain output and software assignable pull-ups.
Alternatively P2 can be used as AD0–AD5.
3
1-bit programmable I/O port.
Schmitt trigger input or push-pull, open-drain output and software assignable pull-ups.
Alternatively P3 can be used as input for external interrupts INT and can be used as AD6–AD11,
and can be used as CLO, BUZ, T0OUT, T0CAP, and T0CLK.
4
1-bit programmable I/O port.
Schmitt trigger input or push-pull, open-drain output and software assignable pull-ups.
Alternatively P4 can be used as AD12–AD14 and can be used as SCK, SI, SO, T2CAP, T1CAP,
T2OUT, and T1OUT and P4.7 can be used as input for external interrupts INT.
5
1-bit programmable I/O port.
Input or push-pull, open-drain output and software assignable pull-ups.
Alternatively P5.0 can be used as input for external interrupts INT and can be used as AD15.
9-1
I/O PORTS
S3C94A5/F94A5
PORT DATA REGISTERS
Table 9-2 gives you an overview of the register locations of all five S3C94A5/F94A5 I/O port data registers. Data
registers for ports 1, 2, 3, 4, and 5 have the general format shown in Figure 9-1.
Table 9-2. Port Data Register Summary
Register Name
Mnemonic
Decimal
Hex
R/W
Port 1 data register
P1
228
E4H
R/W
Port 2 data register
P2
229
E5H
R/W
Port 3 data register
P3
230
E6H
R/W
Port 4 data register
P4
231
E7H
R/W
Port 5 data register
P5
232
E8H
R/W
S3C94A5/F94A5 I/O Port Data Register Format (n = 1-5)
MSB
.7
.6
.5
.4
.3
.2
.1
.0
Pn.7
Pn.6
Pn.5
Pn.4
Pn.3
Pn.2
Pn.1
Pn.0
LSB
Figure 9-1. S3C94A5/F94A5 I/O Port Data Register Format
9-2
S3C94A5/F94A5
I/O PORTS
PORT 1
Port 1 is a 7-bit I/O port with individually configurable pins. Port 1 pins are accessed directly by writing or reading the
port 1 data register, P1 at location E4H in page 0. P1.0–P1.6 can serve as inputs (with or without pull-up), as outputs
(push-pull or open-drain) or you can be configured the following functions.
— Low-nibble pins (P1.0–P1.3): INT
— High-nibble pins (P1.4–P1.6): INT
Port 1 Control Registers (P1CONH, P1CONL)
Port 1 has two 8-bit control registers: P1CONH for P1.4–P1.6 and P1CONL for P1.0–P1.3. A reset clears the
P1CONH and P1CONL registers to “00H”, configuring all pins to input mode. You use control registers setting to
select input (with or without pull-up) or output mode (push-pull or open-drain).
When programming this port, please remember that any alternative peripheral I/O function you configure using the
port 1 control register must also be enabled in the associated peripheral module.
Port 1 Interrupt Enable, Pending, and Edge Selection Registers (P1INT, INTPND1, P1EDGEH/P1EDGEL)
To process external interrupts at the port 1 pins, three additional control registers are provided: the port 1 interrupt
enable register P1INT (ECH, page 0), the port 1 interrupt pending bits INTPND1 (D6H, page 0), and the port 1
interrupt edge selection register P1EDGEH (EDH, page 0) and P1EDGEL (EEH, page 0).
The port 1 interrupt pending register bits lets you check for interrupt pending conditions and clear the pending
condition when the interrupt service routine has been initiated. The application program detects interrupt requests by
polling the INTPND1 register at regular intervals.
When the interrupt enable bit of any port 1 pin is "1", a rising or falling edge at that pin will generate an interrupt
request. The corresponding INTPND1 bit is then automatically set to "1" and the IRQ level goes low to signal the
CPU that an interrupt request is waiting. When the CPU acknowledges the interrupt request, application software
must the clear the pending condition by writing a "0" to the corresponding INTPND1 bit.
9-3
I/O PORTS
S3C94A5/F94A5
Port 1 Control Register, High Byte (P1CONH)
EAH, Page 0, R/W
MSB
.7
.6
.5
.4
.3
P1.6
(INT)
Not used
.2
.1
P1.5
(INT)
.0
LSB
P1.4
(INT)
P1CONH bit-pair pin configuration settings:
00
Schmitt trigger input mode
01
Push-pull output mode
10
N-channel open-drain output mode
11
Schmitt trigger input mode with pull-up
Figure 9-2. Port 1 Control Register, High Byte (P1CONH)
Port 1 Control Register, Low Byte (P1CONL)
EBH, Page 0, R/W
MSB
.7
P1.3
(INT)
.6
.5
.4
.3
P1.2
(INT)
.2
P1.1
(INT)
.1
.0
LSB
P1.0
(INT)
P1CONL bit-pair pin configuration settings:
00
Schmitt trigger input mode
01
Push-pull output mode
10
N-channel open-drain output mode
11
Schmitt trigger input mode with pull-up
Figure 9-3. Port 1 Control Register, Low Byte (P1CONL)
9-4
S3C94A5/F94A5
I/O PORTS
Port 1 Interrupt Control Register (P1INT)
ECH, Page 0, R/W
MSB
.7
.6
Not
used
.5
.4
.3
.2
.1
.0
LSB
P1.6 P1.5 P1.4 P1.3 P1.2 P1.1 P1.0
(INT) (INT) (INT) (INT) (INT) (INT) (INT)
P1INT bit configuration settings:
0
Disable interrupt
1
Enable interrupt
Figure 9-4. Port 1 Interrupt Control Register (P1INT)
Interrupt Pending Register 1 (INTPND1)
D6H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
Not P1.6 P1.5 P1.4 P1.3 P1.2 P1.1 P1.0
used (INT) (INT) (INT) (INT) (INT) (INT) (INT)
INTPND1 bit configuration settings:
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
Figure 9-5. Interrupt Pending Register 1 (INTPND1)
9-5
I/O PORTS
S3C94A5/F94A5
Port 1 Interrupt Edge Selection Register, High Byte (P1EDGEH)
EDH, Page 0, R/W
MSB
.7
.6
.5
.4
.3
P1.6
(INT)
Not used
.2
.1
P1.5
(INT)
.0
LSB
P1.4
(INT)
P1EDGEH bit-pair configuration settings:
00
Falling edge detection
01
Rising edge detection
10
Both rising and falling edges detection
11
Not available
Figure 9-6. Port 1 Interrupt Edge Selection Register, High Byte (P1EDGEH)
Port 1 Interrupt Edge Selection Register, Low Byte (P1EDGEL)
EEH, Page 0, R/W
MSB
.7
.6
P1.3
(INT)
.5
.4
P1.2
(INT)
.3
.2
.1
P1.1
(INT)
.0
LSB
P1.0
(INT)
P1EDGEL bit-pair configuration settings:
00
Falling edge detection
01
Rising edge detection
10
Both rising and falling edges detection
11
Not available
Figure 9-7. Port 1 Interrupt Edge Selection Register, Low Byte (P1EDGEL)
9-6
S3C94A5/F94A5
I/O PORTS
PORT 2
Port 2 is a 6-bit I/O port with individually configurable pins. Port 2 pins are accessed directly by writing or reading the
port 2 data register, P2 at location E5H in page 0. P2.0–P2.5 can serve as inputs (with or without pull-up), as outputs
(push-pull or open-drain) or you can be configured the following functions.
— Low-nibble pins (P2.0–P2.3): AD0–AD3
— High-nibble pins (P2.4–P2.5): AD4–AD5
Port 2 Control Registers (P2CONH, P2CONL)
Port 2 has two 8-bit control registers: P2CONH for P2.4–P2.5 and P2CONL for P2.0–P2.3. A reset clears the
P2CONH and P2CONL registers to "00H", configuring all pins to input mode. You use control registers setting to
select input or output mode (push-pull or open-drain) and enable the alternative functions.
When programming this port, please remember that any alternative peripheral I/O function you configure using the
port 2 control register must also be enabled in the associated peripheral module.
Port 2 Pull-up Resistor Control Register (P2PUR)
Using the port 2 pull-up control register, P2PUR (F1H, page 0), you can configure pull-up resistors to individual port 2
pins.
Port 2 Control Register, High Byte (P2CONH)
EFH, Page 0, R/W
MSB
.7
.6
.5
.4
Not used
.3
.2
P2.5/AD5
.1
.0
LSB
P2.4/AD4
P2CONH bit-pair pin configuration settings:
00
Input mode
01
Push-pull output mode
10
N-channel open-drain output mode
11
Alternative function (AD4, AD5)
Figure 9-8. Port 2 Control Register, High Byte (P2CONH)
9-7
I/O PORTS
S3C94A5/F94A5
Port 2 Control Register, Low Byte (P2CONL)
F0H, Page 0, R/W
MSB
.7
.6
P2.3/AD3
.5
.4
P2.2/AD2
.3
.2
P2.1/AD1
.1
.0
LSB
P2.0/AD0
P2CONL bit-pair pin configuration settings:
00
Input mode
01
Push-pull output mode
10
N-channel open-drain output mode
11
Alternative function (AD0, AD1, AD2, AD3)
Figure 9-9. Port 2 Control Register, Low Byte (P2CONL)
Port 2 Pull-up Control Register (P2PUR)
F1H, Page 0, R/W
MSB
.7
.6
Not used
.5
.4
.3
.2
.1
.0
P2.5
P2.4
P2.3
P2.2
P2.1
P2.0
LSB
P2PUR bit configuration settings:
0
1
NOTE:
Disable pull-up resistor
Enable pull-up resistor
A pull-up resistor of port 2 is automatically disabled when
the corresponding pin is selected as push-pull output or
alternative function.
Figure 9-10. Port 2 Pull-up Control Register (P2PUR)
9-8
S3C94A5/F94A5
I/O PORTS
PORT 3
Port 3 is a 6-bit I/O port with individually configurable pins. Port 3 pins are accessed directly by writing or reading the
port 3 data register, P3 at location E6H in page 0. P3.0–P3.5 can serve as inputs (with or without pull-up), as outputs
(push-pull or open-drain) or you can be configured the following functions.
— Low-nibble pins (P3.0–P3.3): AD6–AD9, CLO, BUZ, T0OUT/T0PWM, INT
— High-nibble pins (P3.4–P3.5): AD10–AD11, T0CAP, T0CLK, INT
Port 3 Control Registers (P3CONH, P3CONL)
Port 3 has two 8-bit control registers: P3CONH for P3.3–P3.5 and P3CONL for P3.0–P3.2. A reset clears the
P3CONH and P3CONL registers to "00H", configuring all pins to input mode. You use control registers setting to
select input or output mode (push-pull or open-drain) and enable the alternative functions.
When programming this port, please remember that any alternative peripheral I/O function you configure using the
port 3 control register must also be enabled in the associated peripheral module.
Port 3 Pull-up Resistor Control Register (P3PUR)
Using the port 3 pull-up control register, P3PUR (F4H, page 0), you can configure pull-up resistors to individually port
3 pins.
Port 3 Interrupt Enable, Pending, and Edge Selection Registers(P3INT, INTPND2.5–0, P3EDGEH/P3EDGEL)
To process external interrupts at the port 3 pins, three additional control registers are provided: the port 3 interrupt
enable register P3INT (F5H, page 0), the port 3 interrupt pending bits INTPND2.5–.0 (D7H, page 0), and the port 3
interrupt edge selection register P3EDGEH (F6H, page 0) and P3EDGEL (F7H, page 0).
The port 3 interrupt pending register bits lets you check for interrupt pending conditions and clear the pending
condition when the interrupt service routine has been initiated. The application program detects interrupt requests by
polling the INTPND2.5–.0 register at regular intervals.
When the interrupt enable bit of any port 3 pin is "1", a rising or falling edge at that pin will generate an interrupt
request. The corresponding INTPND2 bit is then automatically set to "1" and the IRQ level goes low to signal the
CPU that an interrupt request is waiting. When the CPU acknowledges the interrupt request, application software
must the clear the pending condition by writing a "0" to the corresponding INTPND2 bit.
9-9
I/O PORTS
S3C94A5/F94A5
Port 3 Control Register, High Byte (P3CONH)
F2H, Page 0, R/W
MSB
.7
Not
used
.6
.5
P3.5/AD11/
T0CLK
(INT)
.4
.3
P3.4/AD10/
T0CAP
(INT)
.2
.1
.0
LSB
P3.3/AD9/
T0OUT/P0PWM
(INT)
P3CONH.6-.5 and P3CONH.4-.3 bit-pair pin configuration settings:
00
01
Schmitt trigger input mode (T0CAP, T0CLK)
Push-pull output mode
10
11
N-channel open-drain output mode
Alternative function (AD10, AD11)
P3CONH.2-.0 bits pin configuration settings:
000
Schmitt trigger input mode
001
Push-pull output mode
010
N-channel open-drain output mode
011
Alternative function (AD9)
100
Alternative function (T0OUT/T0PWM)
Other Values
Not avaliable
Figure 9-11. Port 3 Control Register, High Byte (P3CONH)
9-10
S3C94A5/F94A5
I/O PORTS
Port 3 Control Register, Low Byte (P3CONL)
F3H, Page 0, R/W
MSB
.7
.6
P3.2/AD8
(INT)
.5
.4
.3
P3.1/AD7/BUZ
(INT)
.2
.1
.0
LSB
P3.0/AD6/CLO
(INT)
P3CONL.7-.6 bit-pair pin configuration settings:
00
Schmitt trigger input mode
01
Push-pull output mode
10
N-channel open-drain output mode
11
Alternative function (AD8)
P3CONL.5-.3 and P3CONL.2-.0 bits pin configuration settings:
000
Schmitt trigger input mode
001
Push-pull output mode
010
N-channel open-drain output mode
011
Alternative function (AD6, AD7)
100
Alternative function (CLO, BUZ)
Other Values
Not available
NOTE:
CLO is CPU clock output.
Figure 9-12. Port 3 Control Register, Low Byte (P3CONL)
9-11
I/O PORTS
S3C94A5/F94A5
Port 3 Interrupt Control Register (P3INT)
F5H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
P3.5 P3.4 P3.3 P3.2 P3.1 P3.0
(INT) (INT) (INT) (INT) (INT) (INT)
Not used
P3INT bit configuration settings:
0
Disable interrupt
1
Enable interrupt
Figure 9-13. Port 3 Interrupt Control Register (P3INT)
Interrupt Pending Register 2 (INTPND2)
D7H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
P5.0 P4.7 P3.5 P3.4 P3.3 P3.2 P3.1 P3.0
(INT) (INT) (INT) (INT) (INT) (INT) (INT) (INT)
INTPND2 bit configuration settings:
0
No interrupt pending (when read), clear pending bit (when write)
1
Interrupt is pending (when read)
Figure 9-14. Interrupt Pending Register 2 (INTPND2)
9-12
S3C94A5/F94A5
I/O PORTS
Port 3 Interrupt Edge Selection Register, High Byte (P3EDGEH)
F6H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
P3.5
(INT)
Not used
.0
LSB
P3.4
(INT)
P3EDGEH bit-pair configuration settings:
00
01
10
11
Falling edge detection
Rising edge detection
Both rising and falling edges detection
Not available
Figure 9-15. Port 3 Interrupt Edge Selection Register, High Byte (P3EDGEH)
Port 3 Interrupt Edge Selection Register, Low Byte (P3EDGEL)
F7H, Page 0, R/W
MSB
.7
.6
P3.3
(INT)
.5
P3.2
(INT)
.4
.3
.2
.1
P3.1
(INT)
.0
LSB
P3.0
(INT)
P3EDGEL bit-pair configuration settings:
00
01
10
11
Falling edge detection
Rising edge detection
Both rising and falling edges detection
Not available
Figure 9-16. Port 3 Interrupt Edge Selection Register, Low Byte (P3EDGEL)
9-13
I/O PORTS
S3C94A5/F94A5
Port 3 Pull-up Control Register (P3PUR)
F4H, Page 0, R/W
MSB
.7
.6
Not used
.5
.4
.3
.2
.1
.0
P3.5
P3.4
P3.3
P3.2
P3.1
P3.0
LSB
P3PUR bit pin configuration settings:
NOTE:
0
Disable pull-up resistor
1
Enable pull-up resistor
A pull-up resistor of port 3 is automatically disabled when the
corresponding pin is selected as push-pull output or alternative
function.
Figure 9-17. Port 3 Pull-up Control Register (P3PUR)
9-14
S3C94A5/F94A5
I/O PORTS
PORT 4
Port 4 is a 8-bit I/O port with individually configurable pins. Port 4 pins are accessed directly by writing or reading the
port 4 data register, P4 at location E7H in page 0. P4.0–P4.7 can serve as inputs (with or without pull-up), as outputs
(push-pull or open-drain) or you can be configured the following functions.
— Low-nibble pins (P4.0–P4.3): AD12–AD13, T1OUT/T1PWM, T2OUT/T2PWM, T1CAP, T2CAP
— High-nibble pins (P4.4–P4.7): SO, SI, SCK, AD14, INT
Port 4 Control Registers (P4CONH, P4CONM and P4CONL)
Port 4 has three 8-bit control registers: P4CONH for P4.6–P4.7, P4CONM for P4.2–P4.5, and P4CONL for P4.0–
P4.1. A reset clears the P4CONH, P4CONM and P4CONL registers to "00H", configuring all pins to input mode. You
use control registers setting to select input or output mode (push-pull or open-drain) and enable the alternative
functions.
When programming this port, please remember that any alternative peripheral I/O function you configure using the
port 4 control register must also be enabled in the associated peripheral module.
Port 4 Pull-up Resistor Control Register (P4PUR)
Using the port 4 pull-up control register, P4PUR (FCH, page 0), you can configure pull-up resistors to individually port
4 pins.
Port 4.7 Interrupt Enable, Pending, and Edge Selection Registers (P4n5INT.4, INTPND2.6, P4n5INT.1–.0)
To process external interrupt at the port 4.7 pin, two additional control registers are provided: the port 4.7 interrupt
enable register P4n5INT.4 (FBH, page 0), the port 4.7 interrupt pending bit INTPND2.6 (D7H, page 0), and the port
4.7 interrupt edge selection register P4n5INT.1–.0 (FBH, page 0).
The port 4.7 interrupt pending register bit lets you check for interrupt pending conditions and clear the pending
condition when the interrupt service routine has been initiated. The application program detects interrupt requests by
polling the INTPND2.6 register at regular intervals.
When the interrupt enable bit of port 4.7 pin is "1", a rising or falling edge at that pin will generate an interrupt
request. The corresponding INTPND2 bit is then automatically set to "1" and the IRQ level goes low to signal the
CPU that an interrupt request is waiting. When the CPU acknowledges the interrupt request, application software
must the clear the pending condition by writing a "0" to the corresponding INTPND2 bit.
9-15
I/O PORTS
S3C94A5/F94A5
Port 4 Control Register, High Byte (P4CONH)
F8H, Page 0, R/W
MSB
.7
.6
.5
.4
Not used
.3
.2
P4.7/AD14
(INT)
.1
.0
LSB
P4.6/SCK
P4CONH bit-pair pin configuration settings:
00
Schmitt trigger input mode (SCK)
01
Push-pull output mode
10
N-channel open-drain output mode
11
Alternative function (SCK, AD14)
Figure 9-18. Port 4 Control Register, High Byte (P4CONH)
Port 4 Control Register, Middle Byte (P4CONM)
F9H, Page 0, R/W
MSB
.7
.6
P4.5/SI
.5
.4
P4.4/SO
.3
.2
.1
.0
LSB
P4.3/T2CAP P4.2/T1CAP
P4CONM bit-pair pin configuration settings:
00
Schmitt trigger input mode (T1CAP, T2CAP, SI)
01
Push-pull output mode
10
N-channel open-drain output mode
11
Alternative function (SO)
Figure 9-19. Port 4 Control Register, Middle Byte (P4CONM)
9-16
S3C94A5/F94A5
I/O PORTS
Port 4 Control Register, Low Byte (P4CONL)
FAH, Page 0, R/W
MSB
.7
.6
.5
Not used
.4
.3
P4.1/AD13/
T2OUT/T2PWM
.2
.1
.0
LSB
P4.0/AD12/
T1OUT/T1PWM
P4CONL bits pin configuration settings:
000
001
010
011
Schmitt trigger input mode
Push-pull output mode
N-channel open-drain output mode
Alternative function (T1OUT/T1PWM, T2OUT/T2PWM)
100
Other Values
Alternative function (AD12-AD13)
Not available
Figure 9-20. Port 4 Control Register, Low Byte (P4CONL)
Port 4 Pull-up Control Register (P4PUR)
FCH, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
P4.7
P4.6
P4.5
P4.4
P4.3
P4.2
P4.1
P4.0
LSB
P4PUR bit configuration settings:
NOTE:
0
Disable pull-up resistor
1
Enable pull-up resistor
A pull-up resistor of port 4 is automatically disabled when
the corresponding pin is selected as push-pull output or
alternative function.
Figure 9-21. Port 4 Pull-up Control Register (P4PUR)
9-17
I/O PORTS
S3C94A5/F94A5
Port 4 and 5 Interrupt Control Register (P4n5INT)
FBH, Page 0, R/W
MSB
.7
.6
.5
Not used
.4
.3
P5.0 P4.7
(INT) (INT)
.2
.1
P5.0
(INT)
.0
LSB
P4.7
(INT)
P4n5INT.5 and P4n5INT.4 bit configuration settings:
0
1
Disable interrupt
Enable interrupt
P4n5INT.3-.2 and P4n5INT.1-.0 bit-pair configuration settings:
00
01
10
11
Falling edge detection
Rising edge detection
Both rising and falling edges detection
Not available
Figure 9-22. Port 4 and 5 Interrupt Control Register (P4n5INT)
Interrupt Pending Register 2 (INTPND2)
D7H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
P5.0 P4.7 P3.5 P3.4 P3.3 P3.2 P3.1 P3.0
(INT) (INT) (INT) (INT) (INT) (INT) (INT) (INT)
INTPND2 bit configuration settings:
0
1
No interrupt pending (when read), clear pending bit (when write)
Interrupt is pending (when read)
Figure 9-23. Interrupt Pending Register 2 (INTPND2)
9-18
S3C94A5/F94A5
I/O PORTS
PORT 5
Port 5 is a 7-bit I/O port with individually configurable pins. Port 5 pins are accessed directly by writing or reading the
port 5 data register, P5 at location E8H in page 0. P5.0–P5.6 can serve as inputs (with or without pull-up) as output
(push-pull or open-drain) or you can be configured the following functions.
— Low-nibble pins (P5.0–P5.3): AD15 and INT for only P5.0
Port 5 Control Registers (P5CONH, P5CONL)
Port 5 has two 8-bit control registers: P5CONH for P5.3–P5.6 and P4CONL for P5.0–P5.2. A reset clears the
P5CONH and P5CONL registers to "00H", configuring all pins to input mode. You use control registers setting to
select input (with or without pull-up) or output mode (push-pull or open-drain) and enable the alternative functions.
When programming this port, please remember that any alternative peripheral I/O function you configure using the
port 5 control register must also be enabled in the associated peripheral module.
Port 5.0 Interrupt Enable, Pending, and Edge Selection Registers (P4n5INT.5, INTPND2.7, P4n5INT.3–.2)
To process external interrupt at the port 5.0 pin, two additional control registers are provided: the port 5.0 interrupt
enable register P4n5INT.5 (FBH, page 0), the port 5.0 interrupt pending bit INTPND2.7 (D7H, page 0), and the port
5.0 interrupt edge selection register P4n5INT.3–.2 (FBH, page 0).
The port 5.0 interrupt pending register bit lets you check for interrupt pending conditions and clear the pending
condition when the interrupt service routine has been initiated. The application program detects interrupt requests by
polling the INTPND2.7 register at regular intervals.
When the interrupt enable bit of port 5.0 pin is "1", a rising or falling edge at that pin will generate an interrupt
request. The corresponding INTPND2 bit is then automatically set to "1" and the IRQ level goes low to signal the
CPU that an interrupt request is waiting. When the CPU acknowledges the interrupt request, application software
must the clear the pending condition by writing a "0" to the corresponding INTPND2 bit.
Port 5 Control Register, High Byte (P5CONH)
FDH, Page 0, R/W
MSB
.7
.6
P5.6
.5
.4
P5.5
.3
.2
.1
P5.4
.0
LSB
P5.3
P5CONH bit-pair pin configuration settings:
00
Input mode
01
Push-pull output mode
10
N-channel open-drain output mode
11
Input mode with pull-up
Figure 9-24. Port 5 Control Register, High-Byte (P5CONH)
9-19
I/O PORTS
S3C94A5/F94A5
Port 5 Control Register, Low Byte (P5CONL)
FEH, Page 0, R/W
MSB
.7
.6
Not used
.5
P5.2
.4
.3
.2
P5.1
.1
.0
LSB
P5.0/AD15
(INT)
P5CONL.6-.5 and P5CONL.4-.3 bit-pair pin configuration settings:
00
Input mode
01
10
11
Push-pull output mode
N-channel open-drain output mode
Input mode with pull-up
P5CONL.2-.0 bits pin configuration settings:
000
001
010
Input mode
Push-pull output mode
N-channel open-drain output mode
011
100
Other Values
Input mode with pull-up
Alternative function (AD15)
Not available
Figure 9-25. Port 5 Control Register, Low-Byte (P5CONL)
Port 4 and 5 Interrupt Control Register (P4n5INT)
FBH, Page 0, R/W
MSB
.7
.6
Not used
.5
.4
P5.0 P4.7
(INT) (INT)
.3
.2
.1
P5.0
(INT)
.0
LSB
P4.7
(INT)
P4n5INT.5 and P4n5INT.4 bit configuration settings:
0
1
Disable interrupt
Enable interrupt
P4n5INT.3-.2 and P4n5INT.1-.0 bit-pair configuration settings:
00
01
10
11
Falling edge detection
Rising edge detection
Both rising and falling edges detection
Not available
Figure 9-26. Port 4 and 5 Interrupt Control Register (P4n5INT)
9-20
S3C94A5/F94A5
I/O PORTS
Interrupt Pending Register 2 (INTPND2)
D7H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
P5.0 P4.7 P3.5 P3.4 P3.3 P3.2 P3.1 P3.0
(INT) (INT) (INT) (INT) (INT) (INT) (INT) (INT)
INTPND2 bit configuration settings:
0
1
No interrupt pending (when read), clear pending bit (when write)
Interrupt is pending (when read)
Figure 9-27. Interrupt Pending Register 2 (INTPND2)
9-21
S3C94A5/F94A5
10
BASIC TIMER
BASIC TIMER
OVERVIEW
Basic timer (BT) can be used in two different ways:
— As a watchdog timer to provide an automatic reset mechanism in the event of a system malfunction.
— To signal the end of the required oscillation stabilization interval after a reset or a stop mode release.
The functional components of the basic timer block are:
— Clock frequency divider (fxx divided by 4096, 1024, 128, or 16) with multiplexer
— 8-bit basic timer counter, BTCNT (DDH, read-only)
— Basic timer control register, BTCON (DCH, read/write)
10-1
BASIC TIMER
S3C94A5/F94A5
BASIC TIMER CONTROL REGISTER (BTCON)
The basic timer control register, BTCON, is used to select the input clock frequency, to clear the basic timer counter
and frequency dividers, and to enable or disable the watchdog timer function. It is located in page 0, address DCH,
and is read/write addressable using Register addressing mode.
A reset clears BTCON to "00H". This enables the watchdog function and selects a basic timer clock frequency of
fxx/4096. To disable the watchdog function, you must write the signature code “1010B” to the basic timer register
control bits BTCON.7–BTCON.4.
The 8-bit basic timer counter, BTCNT (page 0, DDH), can be cleared at any time during normal operation by writing a
"1" to BTCON.1. To clear the frequency dividers for the basic timer input clock and timer counters, you write a "1" to
BTCON.0.
Basic Timer Control Register (BTCON)
DCH, R/W
MSB
.7
.6
.5
.4
.3
Watchdog function enable bits:
1010B
= Disable watchdog timer
Other Value = Enable watchdog timer
.2
.1
.0
LSB
Divider clear bit for basic timer
and timer counters:
0 = No effect
1 = Clear divider
Basic timer counter clear bit:
0 = No effect
1 = Clear BTCNT
Basic timer input clock selection bits:
00 = fXX/4096
01 = fXX/1024
10 = fXX/128
11 = fXX/16
Figure 10-1. Basic Timer Control Register (BTCON)
10-2
S3C94A5/F94A5
BASIC TIMER
BASIC TIMER FUNCTION DESCRIPTION
Watchdog Timer Function
You can program the basic timer overflow signal (BTOVF) to generate a reset by setting BTCON.7–BTCON.4 to any
value other than “1010B”. (The “1010B” value disables the watchdog function.) A reset clears BTCON to “00H”,
automatically enabling the watchdog timer function. A reset also selects the CPU clock (as determined by the
current CLKCON register setting), divided by 4096, as the BT clock.
A reset whenever a basic timer counter overflow occurs. During normal operation, the application program must
prevent the overflow, and the accompanying reset operation, from occurring. To do this, the BTCNT value must be
cleared (by writing a "1" to BTCON.1) at regular intervals.
If a system malfunction occurs due to circuit noise or some other error condition, the BT counter clear operation will
not be executed and a basic timer overflow will occur, initiating a reset. In other words, during normal operation, the
basic timer overflow loop (a bit 7 overflow of the 8-bit basic timer counter, BTCNT) is always broken by a BTCNT clear
instruction. If a malfunction does occur, a reset is triggered automatically.
Oscillation Stabilization Interval Timer Function
You can also use the basic timer to program a specific oscillation stabilization interval following a reset or when stop
mode has been released by an external interrupt.
In stop mode, whenever a reset or an internal and an external interrupt occurs, the oscillator starts. The BTCNT value
then starts increasing at the rate of fxx/4096 (for reset), or at the rate of the preset clock source (for an internal and
an external interrupt). When BTCNT.3 overflows, a signal is generated to indicate that the stabilization interval has
elapsed and to gate the clock signal off to the CPU so that it can resume normal operation.
In summary, the following events occur when stop mode is released:
1.
During stop mode, a power-on reset or an internal and an external interrupt occurs to trigger the stop mode
release and oscillation starts.
2.
If a power-on reset occurred, the basic timer counter will increase at the rate of fx x/4096. If an internal and an
external interrupt is used to release stop mode, the BTCNT value increases at the rate of the preset clock
source.
3.
Clock oscillation stabilization interval begins and continues until bit 3 of the basic timer counter overflows.
4.
When a BTCNT.3 overflow occurs, normal CPU operation resumes.
10-3
BASIC TIMER
S3C94A5/F94A5
RESET or STOP
Bit 1
Bits 3, 2
Basic Timer Control Register
(Write '1010xxxxB' to Disable)
Data Bus
fXX/4096
Clear
fXX/1024
f XX
DIV
fXX/128
MUX
8-Bit Up Counter
(BTCNT, Read-Only)
OVF
fXX/16
R
Start the CPU (note)
Bit 0
NOTE:
During a power-on reset operation, the CPU is idle during the required oscillation
stabilization interval (until bit 4 of the basic timer counter overflows).
Figure 10-2. Basic Timer Block Diagram
10-4
RESET
S3C94A5/F94A5
11
16-BIT TIMER 0
16-BIT TIMER 0
OVERVIEW
Timer/counter 0 has three operating modes, one of which you select using the appropriate T0CON setting:
— Interval timer mode
— Capture input mode with a rising or falling edge trigger at the P3.4 pin
— PWM mode
Timer/counter 0 has the following functional components:
— Clock frequency divider (fxx divided by 1024, 256, 64, 8, or 1) with multiplexer
— External clock input (P3.5, T0CLK)
— 16-bit counter(T0CNTH,T0CNTL), 16-bit comparator, and 16-bit reference data register(T0DATAH,T0DATAL)
— I/O pins for capture input, match output, or PWM output (P3.4/T0CAP, P3.3/T0OUT, P3.3/T0PWM)
— Timer 0 overflow interrupt and match/capture interrupt generation
— Timer 0 control register, T0CON (page 0, B4H, read/write)
TIMER/COUNTER 0 CONTROL REGISTER (T0CON)
You use the timer 0 control register, T0CON, to
— Select the timer 0 operating mode (interval timer, capture mode, or PWM mode)
— Select the timer 0 input clock frequency
— Clear the timer 0 counter, T0CNTH/T0CNTL
— Enable the timer 0 overflow interrupt or timer 0 match/capture interrupt
11-1
16-BIT TIMER 0
S3C94A5/F94A5
T0CON is located in page 0, at address B4H, and is read/write addressable using register addressing mode.
A reset clears T0CON to “00H”. This sets timer 0 to normal interval timer mode, selects an input clock frequency of
fxx/1024, and disables all timer 0 interrupts. You can clear the timer 0 counter at any time during normal operation
by writing a "1" to T0CON.2.
To enable the timer 0 match/capture interrupt (T0INT), you must write T0CON.1 to "1". To detect a match/capture
interrupt pending condition, the application program polls INTPND3.0. When a "1" is detected, a timer 0 match or
capture interrupt is pending. When the interrupt request has been serviced, the pending condition must be cleared by
software by writing a "0" to the timer 0 match/capture interrupt pending bit, INTPND3.0.
Timer 0 Control Register (T0CON)
B4H, R/W
MSB
.7
.6
.5
Timer 0 input clock selection bits:
000 = fxx/1024
001 = fxx/256
010 = fxx/64
011 = fxx/8
100 = fxx
101 = External clock
(P3.5/T0CLK) falling edge
110 = External clock
(P3.5/T0CLK) rising edge
111 = Counter stop
.4
.3
.2
.1
.0
LSB
Timer 0 overflow interrupt enable bit:
0 = Disable overflow interrupt
1 = Enable overflow interrupt
Timer 0 match/capture interrupt enable bit:
0 = Disable interrupt
1 = Enable interrupt
Timer 0 counter clear bit:
0 = No effect
1 = Clear the timer 0 counter (when write)
Timer 0 operating mode selection bits:
00 = Interval mode (P3.3/T0OUT)
01 = Capture mode (capture on rising edge,
counter running, OVF can occur)
10 = Capture mode (capture on falling edge,
counter running, OVF can occur)
11 = PWM mode (OVF and match interrupt can occur)
Figure 11-1. Timer 0 Control Register (T0CON)
11-2
S3C94A5/F94A5
16-BIT TIMER 0
Interrupt Pending Register 3 (INTPND3)
D8H, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
Timer 0 match/capture interrupt pending bit
Watch timer interrupt pending bit
Timer 0 overflow interrupt pending bit
Timer 1 match/capture interrupt pending bit
SIO interrupt pending bit
Timer 1 overflow interrupt pending bit
Timer 2 match/capture interrupt pending bit
Timer 2 overflow interrupt pending bit
0 = Interrupt request is not pending, pending bit clear when write "0".
1 = Interrupt request is pending
Figure 11-2. Interrupt Pending Register 3 (INTPND3)
11-3
16-BIT TIMER 0
S3C94A5/F94A5
TIMER 0 FUNCTION DESCRIPTION
Interval Timer Mode
In interval timer mode, a match signal is generated when the counter value is identical to the value written to the
timer 0 reference data register, T0DATAH/T0DATAL. The match signal generates a timer 0 match interrupt (T0INT)
and clears the counter.
If, for example, you write the value "1087H" to T0DATAH/T0DATAL, the counter will increment until it reaches
“1087H”. At this point, the timer 0 interrupt request is generated, the counter value is reset, and counting resumes.
With each match, the level of the signal at the timer 0 output pin is inverted (see Figure 11-3).
Interrupt Enable/Disable
Capture Signal
CLK
16-Bit Up Counter
16-Bit Comparator
T0CON.1
R (Clear)
M
U
X
Match
T0INT
INTPND3.0
(Match INT)
Pending
T0OUT (P3.3)
Timer 0 Buffer Register
T0CON.4-.3
Match Signal
T0CON.2
T0OVF
Timer 0 Data Register
Figure 11-3. Simplified Timer 0 Function Diagram: Interval Timer Mode
11-4
S3C94A5/F94A5
16-BIT TIMER 0
Pulse Width Modulation Mode
Pulse width modulation (PWM) mode lets you program the width (duration) of the pulse that is output at the T0PWM
(P3.3) pin. As in interval timer mode, a match signal is generated when the counter value is identical to the value
written to the timer 0 data register. In PWM mode, however, the match signal does not clear the counter. Instead, it
runs continuously, overflowing at "FFFFH", and then continues incrementing from "0000H".
Although you can use the match signal to generate a timer 0 overflow interrupt, interrupts are not typically used in
PWM-type applications. Instead, the pulse at the T0PWM (P3.3) pin is held to Low level as long as the reference
data value is less than or equal to ( ≤ ) the counter value and then the pulse is held to High level for as long as the
data value is greater than ( > ) the counter value. One pulse width is equal to tCLK × 65536 (see Figure 11-4).
T0CON.0
Capture Signal
Interrupt Enable/Disable
T0CON.1
T0OVF
CLK
16-Bit Up Counter
INTPND3.1
(Overflow INT)
M
U
X
Match
16-Bit Comparator
Timer 0 Buffer Register
T0INT
INTPND3.0
Pending
T0CON.4-.3
Match Signal
T0CON.2
T0OVF
(Match INT)
T0PWM
Output (P3.3)
High level when
data > counter,
Lower level when
data < counter
Timer 0 Data Register
Figure 11-4. Simplified Timer 0 Function Diagram: PWM Mode
11-5
16-BIT TIMER 0
S3C94A5/F94A5
Capture Mode
In capture mode, a signal edge that is detected at the T0CAP (P3.4) pin opens a gate and loads the current counter
value into the timer 0 data register. You can select rising or falling edges to trigger this operation.
Timer 0 also gives you capture input source: the signal edge at the T0CAP (P3.4) pin. You select the capture input
by setting the values of the timer 0 capture input selection bits in the port 3 control register, P3CONH.4–.3, (page 0,
F2H). When P3CONH.4–.3 is "00", the T0CAP input is selected.
Both kinds of timer 0 interrupts can be used in capture mode: the timer 0 overflow interrupt is generated whenever a
counter overflow occurs; the timer 0 match/capture interrupt is generated whenever the counter value is loaded into
the timer 0 data register.
By reading the captured data value in T0DATAH/T0DATAL, and assuming a specific value for the timer 0 clock
frequency, you can calculate the pulse width (duration) of the signal that is being input at the T0CAP pin (see Figure
11-5).
T0CON.0
T0OVF
CLK
16-Bit Up Counter
INTPND3.1
(Overflow INT)
Interrupt Enable/Disable
T0CON.1
T0CAP input
(P3.4)
Match Signal
M
U
X
T0INT
INTPND3.0
Pending
T0CON.4-.3
T0CON.4-.3
Timer 0 Data Register
Figure 11-5. Simplified Timer 0 Function Diagram: Capture Mode
11-6
(Capture INT)
S3C94A5/F94A5
16-BIT TIMER 0
T0CON.0
T0CON.7-.5
T0OVF
Data BUS
fxx/1024
fxx/256
fxx/64
fxx/8
fxx/1
8
MUX
T0CLK
16-Bit Up Counter
R
(Read-Only)
OVF
INTPND3.1
T0CON.2
Clear
T0CON.1
16-Bit Comparator
Match
T0CAP
M
U
X
T0INT
M
U
X
INTPND3.0
T0OUT
T0PWM
Timer 0 Buffer Register
T0CON.4-.3
Match signal
T0CON.2
T0OVF
T0CON.4-.3
Timer 0 Data Register
8
Data BUS
Figure 11-6. Timer 0 Block Diagram
11-7
S3C94A5/F94A5
12
16-BIT TIMER 1
16-BIT TIMER 1
OVERVIEW
Timer/counter 1 has three operating modes, one of which you select using the appropriate T1CON setting:
— Interval timer mode
— Capture input mode with a rising or falling edge trigger at the P4.2 pin
— PWM mode
Timer/counter 1 has the following functional components:
— Clock frequency divider (fxx divided by 1024, 256, 64, 8, or 1) with multiplexer
— 16-bit counter(T1CNTH,T1CNTL), 16-bit comparator, and 16-bit reference data register(T1DATAH,T1DATAL)
— I/O pins for capture input, match output, or PWM output (P4.2/T1CAP, P4.0/T1OUT, P4.0/T1PWM)
— Timer 1 overflow interrupt and match/capture interrupt generation
— Timer 1 control register, T1CON (page 0, B9H, read/write)
TIMER/COUNTER 1 CONTROL REGISTER (T1CON)
You use the timer 1 control register, T1CON, to
— Select the timer 1 operating mode (interval timer, capture mode, or PWM mode)
— Select the timer 1 input clock frequency
— Clear the timer 1 counter, T1CNTH/T1CNTL
— Enable the timer 1 overflow interrupt or timer 1 match/capture interrupt
12-1
16-BIT TIMER 1
S3C94A5/F94A5
T1CON is located in page 0, at address B9H, and is read/write addressable using register addressing mode.
A reset clears T1CON to "00H". This sets timer 1 to normal interval timer mode, selects an input clock frequency of
fxx/1024, and disables all timer 1 interrupts. You can clear the timer 1 counter at any time during normal operation
by writing a "1" to T1CON.2.
To enable the timer 1 match/capture interrupt (T1INT), you must write T1CON.1 to "1". To detect a match/capture
interrupt pending condition, the application program polls INTPND3.2. When a "1" is detected, a timer 1 match or
capture interrupt is pending. When the interrupt request has been serviced, the pending condition must be cleared by
software by writing a "0" to the timer 1 match/capture interrupt pending bit, INTPND3.2.
Timer 1 Control Register (T1CON)
B9H, R/W
MSB
.7
.6
.5
Timer 1 input clock selection bits:
000 = fxx/1024
001 = fxx/256
010 = fxx/64
011 = fxx/8
100 = fxx
111 = Counter stop
Other Value = Not available
.4
.3
.2
.1
.0
LSB
Timer 1 overflow interrupt enable bit:
0 = Disable overflow interrupt
1 = Enable overflow interrupt
Timer 1 match/capture interrupt enable bit:
0 = Disable interrupt
1 = Enable interrupt
Timer 1 counter clear bit:
0 = No effect
1 = Clear the timer 1 counter (when write)
Timer 1 operating mode selection bits:
00 = Interval mode (P4.0/T1OUT)
01 = Capture mode (capture on rising edge,
counter running, OVF can occur)
10 = Capture mode (capture on falling edge,
counter running, OVF can occur)
11 = PWM mode (OVF and match interrupt can occur)
Figure 12-1. Timer 1 Control Register (T1CON)
12-2
S3C94A5/F94A5
16-BIT TIMER 1
Interrupt Pending Register 3 (INTPND3)
D8H, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
Timer 0 match/capture interrupt pending bit
Watch timer interrupt pending bit
Timer 0 overflow interrupt pending bit
Timer 1 match/capture interrupt pending bit
SIO interrupt pending bit
Timer 1 overflow interrupt pending bit
Timer 2 match/capture interrupt pending bit
Timer 2 overflow interrupt pending bit
0 = Interrupt request is not pending, pending bit clear when write "0".
1 = Interrupt request is pending
Figure 12-2. Interrupt Pending Register 3 (INTPND3)
12-3
16-BIT TIMER 1
S3C94A5/F94A5
TIMER 1 FUNCTION DESCRIPTION
Interval Timer Mode
In interval timer mode, a match signal is generated when the counter value is identical to the value written to the
timer 1 reference data register, T1DATAH/T1DATAL. The match signal generates a timer 1 match interrupt (T1INT)
and clears the counter.
If, for example, you write the value "1087H" to T1DATAH/T1DATAL, the counter will increment until it reaches
“1087H”. At this point, the timer 1 interrupt request is generated, the counter value is reset, and counting resumes.
With each match, the level of the signal at the timer 1 output pin is inverted (see Figure 12-3).
Interrupt Enable/Disable
Capture Signal
CLK
16-Bit Up Counter
16-Bit Comparator
T1CON.1
R (Clear)
M
U
X
Match
T1INT
INTPND3.2
(Match INT)
Pending
T1OUT (P4.0)
Timer 1 Buffer Register
T1CON.4-.3
Match Signal
T1CON.2
T1OVF
Timer 1 Data Register
Figure 12-3. Simplified Timer 1 Function Diagram: Interval Timer Mode
12-4
S3C94A5/F94A5
16-BIT TIMER 1
Pulse Width Modulation Mode
Pulse width modulation (PWM) mode lets you program the width (duration) of the pulse that is output at the T1PWM
(P4.0) pin. As in interval timer mode, a match signal is generated when the counter value is identical to the value
written to the timer 1 data register. In PWM mode, however, the match signal does not clear the counter. Instead, it
runs continuously, overflowing at "FFFFH", and then continues incrementing from "0000H".
Although you can use the match signal to generate a timer 1 overflow interrupt, interrupts are not typically used in
PWM-type applications. Instead, the pulse at the T1PWM (P4.0) pin is held to Low level as long as the reference
data value is less than or equal to ( ≤ ) the counter value and then the pulse is held to High level for as long as the
data value is greater than ( > ) the counter value. One pulse width is equal to tCLK × 65536 (see Figure 12-4).
T1CON.0
Capture Signal
Interrupt Enable/Disable
T1CON.1
T1OVF
CLK
16-Bit Up Counter
16-Bit Comparator
INTPND3.3
(Overflow INT)
M
U
X
Match
Timer 1 Buffer Register
T1INT
INTPND3.2
Pending
T1CON.4-.3
Match Signal
T1CON.2
T1OVF
(Match INT)
T1PWM
Output (P4.0)
High level when
data > counter,
Lower level when
data < counter
Timer 1 Data Register
Figure 12-4. Simplified Timer 1 Function Diagram: PWM Mode
12-5
16-BIT TIMER 1
S3C94A5/F94A5
Capture Mode
In capture mode, a signal edge that is detected at the T1CAP (P4.2) pin opens a gate and loads the current counter
value into the timer 1 data register. You can select rising or falling edges to trigger this operation.
Timer 1 also gives you capture input source: the signal edge at the T1CAP (P4.2) pin. You select the capture input
by setting the values of the timer 1 capture input selection bits in the port 4 control register, P4CONM.1–.0, (page 0,
F9H). When P4CONM.1–.0 is "00", the T1CAP input is selected.
Both kinds of timer 1 interrupts can be used in capture mode: the timer 1 overflow interrupt is generated whenever a
counter overflow occurs; the timer 1 match/capture interrupt is generated whenever the counter value is loaded into
the timer 1 data register.
By reading the captured data value in T1DATAH/T1DATAL, and assuming a specific value for the timer 1 clock
frequency, you can calculate the pulse width (duration) of the signal that is being input at the T1CAP pin (see Figure
12-5).
T1CON.0
T1OVF
CLK
16-Bit Up Counter
INTPND3.3
(Overflow INT)
Interrupt Enable/Disable
T1CON.1
T1CAP input
(P4.2)
Match Signal
M
U
X
T1INT
INTPND3.2
Pending
T1CON.4-.3
T1CON.4-.3
Timer 1 Data Register
Figure 12-5. Simplified Timer 1 Function Diagram: Capture Mode
12-6
(Capture INT)
S3C94A5/F94A5
16-BIT TIMER 1
T1CON.0
T1CON.7-.5
T1OVF
Data BUS
fxx/1024
8
OVF
INTPND3.3
T1CON.2
fxx/256
fxx/64
MUX
16-Bit Up Counter
R
(Read-Only)
Clear
fxx/8
T1CON.1
fxx/1
16-Bit Comparator
Match
T1CAP
M
U
X
T1INT
M
U
X
INTPND3.2
T1OUT
T1PWM
Timer 1 Buffer Register
T1CON.4-.3
Match signal
T1CON.2
T1OVF
T1CON.4-.3
Timer 1 Data Register
8
Data BUS
Figure 12-6. Timer 1 Block Diagram
12-7
S3C94A5/F94A5
13
8-BIT TIMER 2
8-BIT TIMER 2
OVERVIEW
Timer/counter 2 has three operating modes, one of which you select using the appropriate T2CON setting:
— Interval timer mode
— Capture input mode with a rising or falling edge trigger at the P4.3 pin
— PWM mode
Timer/counter 2 has the following functional components:
— Clock frequency divider (fxx divided by 1024, 256, 64, 8, or 1) with multiplexer
— 8-bit counter(T2CNT), 8-bit comparator, and 8-bit reference data register(T2DATA)
— I/O pins for capture input, match output, or PWM output (P4.3/T2CAP, P4.1/T2OUT, P4.1/T2PWM)
— Timer 2 overflow interrupt and match/capture interrupt generation
— Timer 2 control register, T2CON (page 0, BEH, read/write)
TIMER/COUNTER 2 CONTROL REGISTER (T2CON)
You use the timer 2 control register, T2CON, to
— Select the timer 2 operating mode (interval timer, capture mode, or PWM mode)
— Select the timer 2 input clock frequency
— Clear the timer 2 counter, T2CNT
— Enable the timer 2 overflow interrupt or timer 2 match/capture interrupt
13-1
8-BIT TIMER 2
S3C94A5/F94A5
T2CON is located in page 0, at address BEH, and is read/write addressable using register addressing mode.
A reset clears T2CON to "00H". This sets timer 2 to normal interval timer mode, selects an input clock frequency of
fxx/1024, and disables all timer 2 interrupts. You can clear the timer 2 counter at any time during normal operation
by writing a "1" to T2CON.2.
To enable the timer 2 match/capture interrupt (T2INT), you must write T2CON.1 to "1". To detect a match/capture
interrupt pending condition, the application program polls INTPND3.4. When a "1" is detected, a timer 2 match or
capture interrupt is pending. When the interrupt request has been serviced, the pending condition must be cleared by
software by writing a "0" to the timer 2 match/capture interrupt pending bit, INTPND3.4.
Timer 2 Control Register (T2CON)
BEH, R/W
MSB
.7
.6
.5
Timer 2 input clock selection bits:
000 = fxx/1024
001 = fxx/256
010 = fxx/64
011 = fxx/8
100 = fxx
111 = Counter stop
Other Values = Not abailable
.4
.3
.2
.1
.0
LSB
Timer 2 overflow interrupt enable bit:
0 = Disable overflow interrupt
1 = Enable overflow interrupt
Timer 2 match/capture interrupt enable bit:
0 = Disable interrupt
1 = Enable interrupt
Timer 2 counter clear bit:
0 = No effect
1 = Clear the timer 2 counter (when write)
Timer 2 operating mode selection bits:
00 = Interval mode (P4.1/T2OUT)
01 = Capture mode (capture on rising edge,
counter running, OVF can occur)
10 = Capture mode (capture on falling edge,
counter running, OVF can occur)
11 = PWM mode (OVF and match interrupt can occur)
Figure 13-1. Timer 2 Control Register (T2CON)
13-2
S3C94A5/F94A5
8-BIT TIMER 2
Interrupt Pending Register 3 (INTPND3)
D8H, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
Timer 0 match/capture interrupt pending bit
Watch timer interrupt pending bit
Timer 0 overflow interrupt pending bit
Timer 1 match/capture interrupt pending bit
SIO interrupt pending bit
Timer 1 overflow interrupt pending bit
Timer 2 match/capture interrupt pending bit
Timer 2 overflow interrupt pending bit
0 = Interrupt request is not pending, pending bit clear when write "0".
1 = Interrupt request is pending
Figure 13-2. Interrupt Pending Register 3 (INTPND3)
13-3
8-BIT TIMER 2
S3C94A5/F94A5
TIMER 2 FUNCTION DESCRIPTION
Interval Timer Mode
In interval timer mode, a match signal is generated when the counter value is identical to the value written to the
timer 2 reference data register, T2DATA. The match signal generates a timer 2 match interrupt (T2INT) and clears the
counter.
If, for example, you write the value "10H" to T2DATA, the counter will increment until it reaches "10H". At this point,
the timer 2 interrupt request is generated, the counter value is reset, and counting resumes. With each match, the
level of the signal at the timer 2 output pin is inverted (see Figure 13-3).
Interrupt Enable/Disable
Capture Signal
CLK
8-Bit Up Counter
8-Bit Comparator
T2CON.1
R (Clear)
M
U
X
Match
T2INT
INTPND3.4
(Match INT)
Pending
T2OUT (P4.1)
Timer 2 Buffer Register
T2CON.4-.3
Match Signal
T2CON.2
T2OVF
Timer 2 Data Register
Figure 13-3. Simplified Timer 2 Function Diagram: Interval Timer Mode
13-4
S3C94A5/F94A5
8-BIT TIMER 2
Pulse Width Modulation Mode
Pulse width modulation (PWM) mode lets you program the width (duration) of the pulse that is output at the T2PWM
(P4.1) pin. As in interval timer mode, a match signal is generated when the counter value is identical to the value
written to the timer 2 data register. In PWM mode, however, the match signal does not clear the counter. Instead, it
runs continuously, overflowing at "FFH", and then continues incrementing from "00H".
Although you can use the match signal to generate a timer 2 overflow interrupt, interrupts are not typically used in
PWM-type applications. Instead, the pulse at the T2PWM (P4.1) pin is held to Low level as long as the reference
data value is less than or equal to ( ≤ ) the counter value and then the pulse is held to High level for as long as the
data value is greater than ( > ) the counter value. One pulse width is equal to tCLK × 256 (see Figure 13-4).
T2CON.0
Capture Signal
Interrupt Enable/Disable
T2CON.1
T2OVF
CLK
8-Bit Up Counter
INTPND3.5
(Overflow INT)
M
U
X
Match
8-Bit Comparator
Timer 2 Buffer Register
T2INT
INTPND3.4
Pending
T2CON.4-.3
Match Signal
T2CON.2
T2OVF
(Match INT)
T2PWM
Output (P4.1)
High level when
data > counter,
Lower level when
data < counter
Timer 2 Data Register
Figure 13-4. Simplified Timer 2 Function Diagram: PWM Mode
13-5
8-BIT TIMER 2
S3C94A5/F94A5
Capture Mode
In capture mode, a signal edge that is detected at the T2CAP (P4.3) pin opens a gate and loads the current counter
value into the timer 2 data register. You can select rising or falling edges to trigger this operation.
Timer 2 also gives you capture input source: the signal edge at the T2CAP (P4.3) pin. You select the capture input
by setting the values of the timer 2 capture input selection bits in the port 4 control register, P4CONM.3–.2, (page 0,
F9H). When P4CONM.3–.2 is "00", the T2CAP input is selected.
Both kinds of timer 2 interrupts can be used in capture mode: the timer 2 overflow interrupt is generated whenever a
counter overflow occurs; the timer 2 match/capture interrupt is generated whenever the counter value is loaded into
the timer 2 data register.
By reading the captured data value in T2DATA, and assuming a specific value for the timer 2 clock frequency, you
can calculate the pulse width (duration) of the signal that is being input at the T2CAP pin (see Figure 13-5).
T2CON.0
T2OVF
CLK
8-Bit Up Counter
INTPND3.5
(Overflow INT)
Interrupt Enable/Disable
T2CON.1
T2CAP input
(P4.3)
Match Signal
M
U
X
T2INT
INTPND3.4
Pending
T2CON.4-.3
T2CON.4-.3
Timer 2 Data Register
Figure 13-5. Simplified Timer 2 Function Diagram: Capture Mode
13-6
(Capture INT)
S3C94A5/F94A5
8-BIT TIMER 2
T2CON.0
T2CON.7-.5
T2OVF
Data BUS
8
fxx/1024
fxx/256
MUX
fxx/64
8-Bit Up Counter
R
(Read-Only)
OVF
INTPND3.5
T2CON.2
Clear
fxx/8
T2CON.1
fxx/1
8-Bit Comparator
Match
T2CAP
M
U
X
T2INT
M
U
X
INTPND3.4
T2OUT
T2PWM
Timer 2 Buffer Register
T2CON.4-.3
Match signal
T2CON.2
T2OVF
T2CON.4-.3
Timer 2 Data Register
8
Data BUS
Figure 13-6. Timer 2 Block Diagram
13-7
S3C94A5/F94A5
14
WATCH TIMER
WATCH TIMER
OVERVIEW
Watch timer functions include real-time and watch-time measurement and interval timing for the system clock. To
start watch timer operation, set bit 1 of the watch timer control register, WTCON.1 to "1".
And if you want to service watch timer overflow interrupt, then set the WTCON.6 to “1”.
The watch timer overflow interrupt pending condition (INTPND3.7) must be cleared by software in the application's
interrupt service routine by means of writing a "0" to the INTPND3.7 interrupt pending bit.
After the watch timer starts and elapses a time, the watch timer interrupt pending bit (INTPND3.7) is automatically
set to "1", and interrupt requests commence in 3.91ms, 0.25, 0.5 and 1-second intervals by setting Watch timer
speed selection bits (WTCON.3 – .2).
The watch timer can generate a steady 0.5 kHz, 1 kHz, 2 kHz, or 4 kHz signal to BUZ output pin for Buzzer. By
setting WTCON.3 and WTCON.2 to "11b", the watch timer will function in high-speed mode, generating an interrupt
every 3.91 ms. High-speed mode is useful for timing events for program debugging sequences.
Watch timer has the following functional components:
— Real time and watch-time measurement
— Using a main clock source
— I/O pin for buzzer output frequency generator (P3.1, BUZ)
— Timing tests in high-speed mode
— Watch timer overflow interrupt generation
— Watch timer control register, WTCON (page 0, DAH, read/write)
14-1
WATCH TIMER
S3C94A5/F94A5
WATCH TIMER CONTROL REGISTER (WTCON)
The watch timer control register, WTCON is used to select the input clock source, the watch timer interrupt time and
Buzzer signal, to enable or disable the watch timer function. It is located in page 0 at address DAH, and is
read/write addressable using register addressing mode.
A reset clears WTCON to "00H". This disable the watch timer.
So, if you want to use the watch timer, you must write appropriate value to WTCON.
Watch Timer Control Register (WTCON)
DAH, R/W
MSB
.7
.6
.5
.4
Not used
Watch timer INT Enable/Disable bit:
0 = Disable watch timer INT
1 = Enable watch timer INT
Buzzer signal selection bits(fx=4.19 MHz):
00 = 0.5 kHz
01 = 1 kHz
10 = 2 kHz
11 = 4 kHz
.3
.2
.1
.0
LSB
Not used
Watch timer Enable/Disable bit:
0 = Disable watch timer;
clear frequency dividing circuits
1 = Enable watch timer
Watch timer speed selection bits(fx=4.19 MHz):
00 = Set watch timer interrupt to 1 s
01 = Set watch timer interrupt to 0.5 s
10 = Set watch timer interrupt to 0.25 s
11 = Set watch timer interrupt to 3.91 ms
Figure 14-1. Watch Timer Control Register (WTCON)
14-2
S3C94A5/F94A5
WATCH TIMER
WATCH TIMER CIRCUIT DIAGRAM
WTCON.7
WTCON.6
WT INT Enable
BUZ (P3.1)
WTCON.6
WTCON.5
8
MUX
WTCON.4
WTCON.3
WTCON.2
Selector
Circuit
WTCON.1
WTCON.0
WTINT
fW /64 (0.5 kHz)
fW /32 (1 kHz)
fW /16 (2 kHz)
fW /8 (4 kHz)
Enable/Disable
fW
fx/128
32.768 kHz
Frequency
Dividing
Circuit
INTPND3.7
fW/2 7
fW /2 13
fW/214
fW/215 (1 Hz)
fX = Main clock (where fx = 4.19 MHz)
fW = Watch timer frequency
Figure 14-2. Watch Timer Circuit Diagram
14-3
S3C94A5/F94A5
15
A/D CONVERTER
10-BIT ANALOG-TO-DIGITAL CONVERTER
OVERVIEW
The 10-bit A/D converter (ADC) module uses successive approximation logic to convert analog levels entering at one
of the sixteen input channels to equivalent 10-bit digital values. The analog input level must lie between the AVREF
and AVSS values. The A/D converter has the following components:
— Analog comparator with successive approximation logic
— D/A converter logic (resistor string type)
— ADC control register (ADCON)
— Sixteen multiplexed analog data input pins (AD0–AD15)
— 10-bit A/D conversion data output register (ADDATAH/ADDATAL)
— 16-bit digital input port (Alternately, I/O port)
FUNCTION DESCRIPTION
To initiate an analog-to-digital conversion procedure, at first you must set with alternative function for ADC input
enable at port 2, 3, 4, or 5 the pin set with alternative function can be used for ADC analog input. And you write the
channel selection data in the A/D converter control register ADCON.4–.7 to select one of the sixteen analog input
pins (AD0–15) and set the conversion start or enable bit, ADCON.0. The read-write ADCON register is located in
page 0, at address D1H. The pins which are not used for ADC can be used for normal I/O.
During a normal conversion, ADC logic initially sets the successive approximation register to 800H (the approximate
half-way point of an 10-bit register). This register is then updated automatically during each conversion step. The
successive approximation block performs 10-bit conversions for one input channel at a time. You can dynamically
select different channels by manipulating the channel selection bit value (ADCON.7–.4) in the ADCON register. To
start the A/D conversion, you should set the enable bit, ADCON.0. When a conversion is completed, ADCON.3,
the end-of-conversion(EOC) bit is automatically set to 1 and the result is dumped into the ADDATAH/ADDATAL
register where it can be read. The A/D converter then enters an idle state. Remember to read the contents of
ADDATAH/ADDATAL before another conversion starts. Otherwise, the previous result will be overwritten by the next
conversion result.
NOTE
Because the A/D converter has no sample-and-hold circuitry, it is very important that fluctuation in the analog level at
the AD0–AD15 input pins during a conversion procedure be kept to an absolute minimum. Any change in the input
level, perhaps due to noise, will invalidate the result. If the chip enters to STOP or IDLE mode in conversion process,
there will be a leakage current path in A/D block. You must use STOP or IDLE mode after ADC operation is finished.
15-1
A/D CONVERTER
S3C94A5/F94A5
CONVERSION TIMING
The A/D conversion process requires 4 steps (4 clock edges) to convert each bit and 10 clocks to set-up A/D
conversion. Therefore, total of 50 clocks are required to complete an 10-bit conversion: When fxx/8 is selected for
conversion clock with an 4.5 MHz fxx clock frequency, one clock cycle is 1.78 us. Each bit conversion requires 4
clocks, the conversion rate is calculated as follows:
4 clocks/bit × 10-bit + set-up time = 50 clocks, 50 clock × 1.78 us = 89 us at 0.56 MHz (4.5 MHz/8)
Note that A/D converter needs at least 25µs for conversion time.
A/D CONVERTER CONTROL REGISTER (ADCON)
The A/D converter control register, ADCON, is located at address D1H in page 0. It has three functions:
— Analog input pin selection (bits 4, 5, 6 and 7)
— End-of-conversion status detection (bit 3)
— ADC clock selection (bits 2 and 1)
— A/D operation start or enable (bit 0)
After a reset, the start bit is turned off. You can select only one analog input channel at a time. Other analog input
pins (AD0–AD15) can be selected dynamically by manipulating the ADCON.4–.7 bits. And the pins not used for
analog input can be used for normal I/O function.
A/D Converter Control Register (ADCON)
D1H, Page0, R/W (EOC bit is read-only)
MSB
.7
.6
.5
.4
.3
A/D input pin selection bits:
0000 = AD0
0001 = AD1
0010 = AD2
0011 = AD3
0100 = AD4
End-of-conversion bit:
0101 = AD5
0 = Not complete Conversion
0110 = AD6
1 = Complete Conversion
0111 = AD7
1000 = AD8
1001 = AD9
1010 = AD10
1011 = AD11
1100 = AD12
1101 = AD13
1110 = AD14
1111 = AD15
.2
.1
.0
LSB
Start or enable bit:
0 = Disable operation
1 = Start operation
(Automatically disable
the operation after
conversion completes.)
Clock Selection bits:
00 = fxx/16
01 = fxx/8
10 = fxx/4
11 = fxx/1
Figure 15-1. A/D Converter Control Register (ADCON)
15-2
S3C94A5/F94A5
A/D CONVERTER
A/D Converter Data Register ADDATAH/ADDATAL
D2H/D3H, Page 0, Read Only
MSB
.9
.8
.7
MSB
.6
.5
.4
.3
.2
LSB
(ADDATAH)
.1
.0
LSB
(ADDATAL)
Figure 15-2. A/D Converter Data Register (ADDATAH/ADDATAL)
INTERNAL REFERENCE VOLTAGE LEVELS
In the ADC function block, the analog input voltage level is compared to the reference voltage. The analog input level
must remain within the range VSS to VDD.
Different reference voltage levels are generated internally along the resistor tree during the analog conversion process
for each conversion step. The reference voltage level for the first conversion bit is always 1/2 VDD.
15-3
A/D CONVERTER
S3C94A5/F94A5
BLOCK DIAGRAM
ADCON.2-.1
ADCON.4-7
(Select one input pin of the assigned pins)
AD0-AD5
Input Pins
(P2.0-P2.5)
AD6-AD11
Input Pins
(P3.0-P3.5)
AD12-AD13
Input Pins
(P4.0-P4.1)
ADCON.0
(AD/C Enable)
..
.
..
.
Clock
Selector
M
U
X
Analog
Comparator
+
Successive
Approximation
Logic & Register
ADCON.0
(AD/C Enable)
..
.
AD14-AD15
Input Pins
(P4.7-P5.0)
10-bit D/A
Converter
AVREF
AVSS
Conversion Result
(ADDATAH/ADDATAL,
D2H/D3H)
P2CONH/L, P3CONH/L
P4CONH/L, P5CONL
(Assign Pins to ADC Input)
Figure 15-3. A/D Converter Functional Block Diagram
15-4
To ADCON.3
(EOC Flag)
S3C94A5/F94A5
A/D CONVERTER
VDD
Reference
Voltage Input
(AVREF ≤ VDD)
AVREF
+
10µF
-
C 103
S3C94A5
VDD
Analog
Input Pin
AD0-AD15
C 101
AVSS
Figure 15-4. Recommended A/D Converter Circuit for Highest Absolute Accuracy
15-5
S3C94A5/F94A5
16
SERIAL I/O INTERFACE
SERIAL I/O INTERFACE
OVERVIEW
Serial I/O modules, SIO can interface with various types of external device that require serial data transfer. The
components of SIO function block are:
— 8-bit control register (SIOCON)
— Clock selector logic
— 8-bit data buffer (SIODATA)
— 8-bit prescaler (SIOPS)
— 3-bit serial clock counter
— Serial data I/O pins (SI, SO)
— Serial clock input/output pin (SCK)
The SIO module can transmit or receive 8-bit serial data at a frequency determined by its corresponding control
register settings. To ensure flexible data transmission rates, you can select an internal or external clock source.
PROGRAMMING PROCEDURE
To program the SIO module, follow these basic steps:
1.
Configure the I/O pins at port (SCK/SI/SO) by loading the appropriate value to the P4CONM and P4CONH
register if necessary.
2.
Load an 8-bit value to the SIOCON control register to properly configure the serial I/O module. In this operation,
SIOCON.2 must be set to "1" to enable the data shifter.
3.
For interrupt generation, set the serial I/O interrupt enable bit (SIOCON) to "1".
4.
When you transmit data to the serial buffer, write data to SIODATA and set SIOCON.3 to 1, the shift operation
starts.
5.
When the shift operation (transmit/receive) is completed, the SIO pending bit (INTPND3.6) is set to "1" and SIO
interrupt request is generated.
16-1
SERIAL I/O INTERFACE
S3C94A5/F94A5
SIO CONTROL REGISTERS (SIOCON)
The control register for serial I/O interface module, SIOCON, is located at E1H in page 0. It has the control setting
for SIO module.
— Clock source selection (internal or external) for shift clock
— Interrupt enable
— Edge selection for shift operation
— Clear 3-bit counter and start shift operation
— Shift operation (transmit) enable
— Mode selection (transmit/receive or receive-only)
— Data direction selection (MSB first or LSB first)
A reset clears the SIOCON value to "00H". This configures the corresponding module with an internal clock source
at the SCK, selects receive-only operating mode, and clears the 3-bit counter. The data shift operation and the
interrupt are disabled. The selected data direction is MSB-first.
Serial I/O Module Control Register (SIOCON)
E1H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
SIO mode selection bit:
0 = Receive only mode
1 = Transmit/receive mode
.0
LSB
Not used
SIO shift clock selection bit:
0 = Internal clock (P.S Clock)
1 = External clock (SCK)
Data direction control bit:
0 = MSB-first mode
1 = LSB-first mode
.1
SIO interrupt enable bit:
0 = Disable SIO interrupt
1 = Enable SIO interrupt
SIO shift operation enable bit:
0 = Disable shifter and clock counter
1 = Enable shifter and clock counter
SIO counter clear and shift start bit:
0 = No action
1 = Clear 3-bit counter and start shifting
Shift clock edge selection bit:
0 = t X at falling edeges, rx at rising edges.
1 = t X at rising edeges, rx at falling edges.
Figure 16-1. Serial I/O Module Control Register (SIOCON)
16-2
S3C94A5/F94A5
SERIAL I/O INTERFACE
SIO PRE-SCALER REGISTER (SIOPS)
The prescaler register for serial I/O interface module, SIOPS, are located at E3H in page 0.
The value stored in the SIO pre-scale register, SIOPS, lets you determine the SIO clock rate (baud rate) as follows:
Baud rate = Input clock (fxx/2)/(Prescaler value + 1), or SCK input clock.
SIO Pre-scaler Register (SIOPS)
E3H, Page 0, R/W
MSB
.7
.6
.5
.4
.3
.2
.1
.0
LSB
Baud rate = (fXX/2)/(SIOPS + 1)
Figure 16-2. SIO Prescaler Register (SIOPS)
SIO BLOCK DIAGRAM
CLK
SIO INT
3-Bit Counter
Clear
INTPND3.6
Pending
SIOCON.1
(Interrupt Enable)
SIOCON.3
SIOCON.7
SIOCON.4
(Edge Select)
M
SCK
SIOPS (E3H, page 0)
fxx
SIOCON.2
(Shift Enable)
8-bit P.S.
U
1/2
X
SIOCON.5
(Mode Select)
CLK 8-Bit SIO Shift Buffer
(SIODATA, E2H, page 0)
8
SO
SIOCON.6
(LSB/MSB First
Mode Select)
SI
Data Bus
Figure 16-3. SIO Functional Block Diagram
16-3
SERIAL I/O INTERFACE
S3C94A5/F94A5
SERIAL I/O TIMING DIAGRAM (SIO)
SCK
SI
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DI0
SO
DO7
DO6
DO5
DO4
DO3
DO2
DO1
DO0
Transmit
Complete
SIO INT
Set SIOCON.3
Figure 16-4. Serial I/O Timing in Transmit/Receive Mode (Tx at falling, SIOCON.4 = 0)
SCK
SI
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DI0
SO
DO7
DO6
DO5
DO4
DO3
DO2
DO1
DO0
Transmit
Complete
SIO INT
Set SIOCON.3
Figure 16-5. Serial I/O Timing in Transmit/Receive Mode (Tx at rising, SIOCON.4 = 1)
16-4
S3C94A5/F94A5
17
ELECTRICAL DATA
ELECTRICAL DATA
OVERVIEW
In this chapter, S3C94A5/F94A5 electrical characteristics are presented in tables and graphs. The information is
arranged in the following order:
— Absolute maximum ratings
— D.C. electrical characteristics
— Data retention supply voltage in Stop mode
— Stop mode release timing when initiated by an external interrupt
— Stop mode release timing when initiated by a Reset
— I/O capacitance
— A.C. electrical characteristics
— A/D converter electrical characteristics
— Input timing for external interrupt
— Input timing for RESET
— Serial data transfer timing
— Oscillation characteristics
— Oscillation stabilization time
— Operating voltage range
17-1
ELECTRICAL DATA
S3C94A5/F94A5
Table 17-1. Absolute Maximum Ratings
(TA = 25°C)
Parameter
Supply voltage
Symbol
Conditions
Rating
Unit
VDD
–
– 0.3 to + 6.5
V
– 0.3 to VDD + 0.3
V
– 0.3 to VDD + 0.3
V
Input voltage
VI
Output voltage
VO
Output current High
IOH
Ports 1–5
–
One I/O pin active
All I/O pins active
Output current Low
IOL
Storage temperature
17-2
42-SDIP
– 60
44-QFP
– 90
One I/O pin active
All I/O pin active
Operating
temperature
– 15
mA
+ 30
42-SDIP
+ 100
44-QFP
+ 150
mA
TA
–
– 25 to + 85
°C
TSTG
–
– 65 to + 150
°C
S3C94A5/F94A5
ELECTRICAL DATA
Table 17-2. D.C. Electrical Characteristics
(TA = – 25°C to + 85°C, VDD = 2.0 V to 5.5 V)
Parameter
Operating voltage
Input high voltage
Input low voltage
Output high voltage
Symbol
VDD
Conditions
Min
Typ
Max
Unit
fx = 0.4–4MHz
2.0
–
5.5
V
fx = 0.4–8MHz
2.7
–
5.5
fx = 0.4–12 MHz
3.0
–
5.5
VIH1
Ports 2, 5
0.7 VDD
–
VDD
V
VIH2
Ports 1, 3, 4 nRESET
0.8 VDD
–
VDD
VIH3
XIN, XOUT
VDD – 0.1
–
VDD
VIL1
Ports 2, 5
–
–
0.3 VDD
VIL2
Ports 1, 3, 4, nRESET
–
–
0.2 VDD
VIL3
XIN, XOUT
–
–
0.1
VOH
VDD = 2.7 to 5.5 V;
VDD – 1.0
–
VDD
V
–
–
1.0
V
–
–
1.0
–
–
3
–
–
20
V
All output ports; IOH = –3 mA
Output low voltage
VOL1
VDD = 2.7 to 5.5 V;
All output ports; IOL = 15 mA
VOL2
VDD = 3.3 V;
All output ports; IOL = 20 mA
Input high leakage
current
ILIH1
VI = VDD;
µA
All input pins except XIN, XOUT
ILIH2
VI = VDD;
XIN, XOUT
17-3
ELECTRICAL DATA
S3C94A5/F94A5
Table 17-2. D.C. Electrical Characteristics (Continued)
(TA = – 25°C to + 85°C, VDD = 2.0 V to 5.5 V)
Parameter
Input low
leakage current
Symbol
Conditions
Min
Typ
Max
Unit
–
–
–3
µA
ILIL1
VI = 0 V;
All input pins except nRESET,
ILIL2
ILIL2
VI = 0 V;
XIN, XOUT
Output high
leakage current
ILOH
VO = VDD
All output pins
–
–
3
Output low
leakage current
ILOL
VO = 0 V
–
–
–3
Pull-up resistor
RL1
VI = 0 V; VDD = 5V, TA = 25°C
Ports 1–5
15
35
70
VDD = 3V, TA = 25°C
30
70
140
VI = 0 V; VDD = 5V, TA = 25°C
nRESET
150
250
400
VDD = 3V, TA = 25°C
300
500
700
VDD = 5 V, TA = 25 °C
XIN = VDD, XOUT = 0V
300
600
1500
All output pins
RL2
Oscillator feed
back resistors
NOTE:
17-4
–20
ROSC1
Low leakage current is absolute value.
kΩ
kΩ
S3C94A5/F94A5
ELECTRICAL DATA
Table 17-2. D.C. Electrical Characteristics (Concluded)
(TA = – 25°C to + 85°C, VDD = 2.0 V to 5.5 V)
Parameter
Symbol
Supply current (1)
IDD1
IDD2
IDD3(2)
Conditions
Min
Typ
Max
Unit
–
6.0
18.0
mA
Run mode:
VDD = 5 V ± 10%
12.0 MHz
Crystal oscillator
C1 = C2 = 22pF
4.19 MHz
2.5
6.0
VDD = 3 V ± 10%
8.0 MHz
2.5
5.0
4.19 MHz
1.5
3.0
Idle mode:
VDD = 5 V ± 10%
12.0 MHz
1.5
4.0
Crystal oscillator
C1 = C2 = 22pF
4.19 MHz
1.0
2.0
VDD = 3 V ± 10%
8.0 MHz
0.5
1.6
4.19 MHz
0.4
0.8
0.5
3
0.3
2
–
10
Stop mode; VDD = 5 V ± 10%,
µA
TA = 25 °C
Stop mode; VDD = 3 V ± 10%,
TA = 25 °C
TA = –25 °C to + 85 °C
NOTES:
1. Supply current does not include current drawn through internal pull-up resistors and ADC.
2. IDD3 is current when main clock and oscillation stops.
3.
Every values in this table is measured when bits 4 -3 of the system clock control register (CLKCON.4–.3) is set to 11B.
17-5
ELECTRICAL DATA
S3C94A5/F94A5
Table 17-3. Data Retention Supply Voltage in Stop Mode
(TA = – 25 °C to + 85 °C)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Data retention supply
voltage
VDDDR
–
2.0
–
5.5
V
Data retention supply
current
IDDDR
–
–
1
µA
Stop mode, TA = 25 °C
VDDDR = 2.0 V
Idle Mode
(Basic Timer Active)
~
~
Stop Mode
Normal
Operating Mode
Data Retention Mode
~
~
VDD
VDDDR
Execution of
STOP Instruction
0.8 V DD
t WAIT
NOTE:
t WAIT is the same as 16 x 1/BT clock.
Figure 17-1. Stop Mode Release Timing When Initiated by an External Interrupt
17-6
S3C94A5/F94A5
ELECTRICAL DATA
Oscillation
Stabilization
TIme
RESET
Occurs
~
~
Stop Mode
Normal
Operating Mode
Data Retention Mode
~
~
VDD
VDDDR
Execution of
STOP Instrction
nRESET
0.8 VDD
0.2 VDD
NOTE:
t WAIT
tWAIT is the same as 16 × 1/BT clock.
Figure 17-2. Stop Mode Release Timing When Initiated by a RESET
Table 17-4. Input/Output Capacitance
(TA = 25 °C, VDD = 0 V)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Input
capacitance
CIN
f = 1 MHz; unmeasured pins
are connected to VSS
–
–
10
pF
Output
capacitance
COUT
I/O capacitance
CIO
17-7
ELECTRICAL DATA
S3C94A5/F94A5
Table 17-5. A.C. Electrical Characteristics
(TA = – 25°C to + 85°C, VDD = 2.7 V to 5.5 V)
Parameter
SCK cycle time
SCK high, low width
Symbol
tKCY
tKH, tKL
SI setup time to SCK
high
tSIK
SI hold time to SCK high
tKSI
Output delay for SCK to
SO
tKSO
Interrupt input, High, Low
width
tINTH,
nRESET input Low width
tRSL
17-8
Conditions
Min
Typ
Max
Unit
External SCK source
330
–
–
ns
Internal SCK source
330
External SCK source
165
Internal SCK source
tKCY /2–20
External SCK source
80
Internal SCK source
80
External SCK source
130
Internal SCK source
130
External SCK source
–
–
100
ns
Internal SCK source
tINTL
80
All interrupt
VDD = 3 V
500
700
–
ns
Input
VDD = 3 V
10
–
–
µs
S3C94A5/F94A5
ELECTRICAL DATA
Table 17-6. A/D Converter Electrical Characteristics
(TA = – 25°C to + 85°C, VDD = 2.7 V to 5.5 V, VSS = 0 V)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Resolution
–
–
–
10
–
bit
Total accuracy
–
VDD = 5.12 V
–
–
±3
LSB
–
–
±2
Integral linearity error
ILE
AVREF = 5.12 V
Differential linearity error
DLE
AVSS = 0 V
–
–
±1
Offset error of top
EOT
CPU clock = 8 MHz
–
±1
±3
Offset error of bottom
EOB
–
±1
±3
Conversion time (1)
TCON
25
–
–
µS
Analog input voltage
VIAN
–
AVSS
–
AVREF
V
Analog input impedance
RAN
–
2
1000
–
MΩ
Analog reference voltage
AVREF
–
2.7
–
VDD
V
Analog ground
AVSS
–
VSS
–
VSS+0.3
V
Analog input current
IADIN
AVREF = VDD = 5 V
–
–
10
µA
Analog block current (2)
IADC
AVREF = VDD = 5 V
–
1
3
mA
AVREF = VDD = 3 V
0.5
1.5
AVREF = VDD = 5 V
When power down mode
100
500
10-bit resolution
50 × fxx/4, fxx = 8MHz
nA
NOTES:
1. 'Conversion time' is the time required from the moment a conversion operation starts until it ends.
2. IADC is an operating current during A/D conversion.
t INTL
External
Interrupt
t INTH
0.8 V DD
0.2 V DD
NOTE:
The unit t CPU means one CPU clock period.
Figure 17-3. Input Timing for External Interrupts
17-9
ELECTRICAL DATA
S3C94A5/F94A5
tRSL
nRESET
0.2 VDD
Figure 17-4. Input Timing for nRESET
tKCY
tKL
t KH
SCK
0.8VDD
0.2VDD
tSIK
tKSI
0.8VDD
SI
0.2VDD
tKSO
SO
Output Data
Figure 17-5. Serial Data Transfer Timing
17-10
S3C94A5/F94A5
ELECTRICAL DATA
Table 17-7. Main Oscillation Characteristics
(TA = – 25°C to + 85°C)
Oscillator
Clock Configuration
Crystal
C1
XIN
Parameter
Crystal oscillation
frequency
XOUT
Test Condition
Min
Typ
Max
Units
3.0 V – 5.5 V
0.4
–
12
MHz
2.7 V – 5.5 V
0.4
–
8
2.0 V – 5.5 V
0.4
–
4
3.0 V – 5.5 V
0.4
–
12
2.7 V – 5.5 V
0.4
–
8
2.0 V – 5.5 V
0.4
–
4
3.0 V – 5.5 V
0.4
–
12
2.7 V – 5.5 V
0.4
–
8
2.0 V – 5.5 V
0.4
–
4
5.0 V
0.4
–
2
3.0 V
0.4
–
1
C2
Ceramic
Oscillator
C1
XIN
Ceramic oscillation
frequency
XOUT
C2
External
Clock
XIN input frequency
XIN
XOUT
RC
Oscillator
(mode1)
Frequency
XIN
MHz
R
XOUT
17-11
ELECTRICAL DATA
S3C94A5/F94A5
Table 17-8. Main Oscillator Stabilization Time
(TA = – 25 °C to + 85 °C, VDD = 2.0 V to 3.6 V)
Oscillator
Test Condition
Min
Typ
Max
Unit
Crystal
fx > 1 MHz
–
–
40
ms
Ceramic
Oscillation stabilization occurs when VDD is
–
–
10
ms
41
–
1250
ns
equal to the minimum oscillator voltage
range.
External clock
XIN input high and low width (t XH, tXL)
1/fx
tXL
t XH
XIN
VDD-0.1 V
0.1 V
Figure 17-6. Clock Timing Measurement at XIN
17-12
S3C94A5/F94A5
ELECTRICAL DATA
Table 17-9. External RC Oscillation (Mode 2) Characteristics
(TA = – 25 °C to + 85 °C, VDD = 2.7 V to 5.5 V)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
4
–
8
MHz
%
RC oscillator frequency
range (1)
fERC
TA = 25 °C
Accuracy of RC oscillation
ACCERC
VDD = 3.3 V, TA = 25 °C
–7
–
+7
VDD = 3.3 V,
–15
–
+15
–
–
10
ms
(2)
TA = –25 °C to 85 °C
RC oscillator setup time (3)
tSUERC
TA = 25 °C
NOTES:
1. The frequency is adjusted by external resistor.
2. The min/max frequencies are within the range of RC OSC frequency (4 MHz to 8 MHz).
3. Data based on characterization results, not tested in production.
4. The external resistor is connected between VDD and XIN pin (XOUT pin should be open).
Table 17-10. Internal RC Oscillation Characteristics
(TA = – 10 °C to + 70 °C, VDD = 3.0 V to 5.5 V)
Parameter
RC oscillator frequency
range (1)
Symbol
fIRC
Conditions
Min
Typ
Max
Unit
VDD = 3.3 V, TA = 25 °C
7
9
11
MHz
VDD = 3.3 V,
6
9
12
MHz
40
50
60
%
–
–
10
ms
TA = –10 °C to 70 °C
Clock duty ratio
TOD
RC oscillator setup time (2)
tSUIRC
–
TA = 25 °C
NOTES:
1. The internal RC OSC frequency is 9 MHz(typ) only.
2. Data based on characterization results, not tested in production.
3. XIN and XOUT pins should be open.
17-13
ELECTRICAL DATA
S3C94A5/F94A5
Instruction Clock
fx (oscillation frequency)
3 MHz
12 MHz
2 MHz
8 MHz
1 MHz
4 MHz
6.25 kHz
400 kHz
1
2
3
2.7
4
5
6
7
5.5
Supply Voltage (V)
Instruction Clock = 1/4n x oscillator frequency (n = 1, 2, 8, 16)
Figure 17-7. Operating Voltage Range
17-14
S3C94A5/F94A5
18
MECHANICAL DATA
MECHANICAL DATA
OVERVIEW
The S3C94A5/F94A5 microcontroller is currently available in a 42-pin SDIP and 44-pin QFP package.
#22
0.2
5
42-SDIP-600
+0
- 0. .1
05
0-15
15.24
14.00 ± 0.2
#42
(1.77)
NOTE:
1.00 ±
0.1
5.08 MAX
39.10 ± 0.2
0.1
3.30 ± 0.3
0.2
39.50 MAX
0.50 ±
3.50 ±
#21
0.51 MIN
#1
1.78
Dimensions are in millimeters.
Figure 18-1. 42-SDIP-600 Package Dimensions
18-1
MECHANICAL DATA
S3C94A5/F94A5
13.20 ± 0.3
0-8
10.00 ± 0.2
+ 0.10
10.00 ± 0.2
0.10 MAX
44-QFP-1010B
0.80 ± 0.20
13.20 ± 0.3
0.15 - 0.05
#44
#1
+ 0.10
0.35 - 0.05
0.80
(1.00)
0.05 MIN
2.05 ± 0.10
2.30 MAX
NOTE : Dimensions are in millimeters.
Figure 18-2. 44-QFP-1010B Package Dimensions
18-2
S3C94A5/F94A5
19
S3F94A5 FLASH MCU
S3F94A5 FLASH MCU
OVERVIEW
The S3F94A5 single-chip CMOS microcontroller is the Flash MCU version of the S3C94A5 microcontroller. It has an
on-chip Flash MCU ROM instead of a masked ROM. The Flash ROM is accessed by serial data format.
The S3F94A5 is fully compatible with the S3C94A5, both in function and in pin configuration. Because of its simple
programming requirements, the S3F94A5 is ideal as an evaluation chip for the S3C94A5.
19-1
S3C94A5/F94A5
44
43
42
41
40
39
38
37
36
35
34
P1.0/INT
VDD1/VDD
XIN
XOUT
VSS1/VSS
nRESET/nRESET
TEST/VPP
P5.6
P5.5
P5.4
P5.3
S3F94A5 FLASH MCU
1
2
3
4
5
6
7
8
9
10
11
S3F94A5
(44-QFP-1010B)
33
32
31
30
29
28
27
26
25
24
23
P5.2
P5.1
P5.0/AD15/INT
P4.7/AD14/INT
P4.6/SCK/SCLK
P4.5/SI
P4.4/SO/SDAT
P4.3/T2CAP
P4.2/T1CAP
P4.1/AD13/T2OUT/T2PWM
P4.0/AD12/T1OUT/T1PWM
P2.5/AD5
AVREF
AVSS
P3.0/AD6/CLO/INT
P3.1/AD7/BUZ/INT
P3.2/AD8/INT
P3.3/AD9/T0OUT/T0PWM/INT
P3.4/AD10/T0CAP/INT
P3.5/AD11/T0CLK/INT
VDD2
VSS2
12
13
14
15
16
17
18
19
20
21
22
P1.1/INT
P1.2/INT
P1.3/INT
P1.4/INT
P1.5/INT
P1.6/INT
P2.0/AD0
P2.1/AD1
P2.2/AD2
P2.3/AD3
P2.4/AD4
Figure 19-1. S3F94A5 Pin Assignments (44-QFP-1010B)
19-2
S3C94A5/F94A5
S3F94A5 FLASH MCU
S3F94A5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
(42-SDIP-600)
P1.6/INT
P2.0/AD0
P2.1/AD1
P2.2/AD2
P2.3/AD3
P2.4/AD4
P2.5/AD5
AVREF
AVSS
P3.0/AD6/CLO/INT
P3.1/AD7/BUZ/INT
P3.2/AD8/INT
P3.3/AD9/T0OUT/T0PWM.INT
P3.4/AD10/T0CAP/INT
P3.5/AD11/T0CLK/INT
P4.0/AD12/T1OUT/T1PWM
P4.1/AD13/T2OUT/T2PWM
P4.2/T1CAP
P4.3/T2CAP
SDAT/P4.4/SO
P4.5/SI
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
P1.5/INT
P1.4/INT
P1.3/INT
P1.2/INT
P1.1/INT
P1.0/INT
VDD1/VDD
XIN
XOUT
VSS1/VSS
nRESET/nRESET
TEST/VPP
P5.6
P5.5
P5.4
P5.3
P5.2
P5.1
P5.0/AD15/INT
P4.7/AD14/INT
P4.6/SCK/SCLK
Figure 19-2. S3F94A5 Pin Assignments (42-SDIP-600)
19-3
S3F94A5 FLASH MCU
S3C94A5/F94A5
Table 19-1. Descriptions of Pins Used to Read/Write the Flash ROM
Main Chip
During Programming
Pin Name
Pin Name
Pin No.
I/O
Function
P4.4
SDAT
27(20)
I/O
Serial data pin. Output port when reading and input
port when writing. Can be assigned as a
Input/push-pull output port.
P4.6
SCLK
29(22)
I/O
Serial clock pin. Input only pin.
TEST
VPP
38(31)
I
Power supply pin for flash ROM cell writing
(indicates that flash MCU enters into the writing
mode). When 12.5 V is applied, flash MCU is in
writing mode and when 5 V is applied, flash MCU
is in reading mode. (option)
nRESET
nRESET
39(32)
I
Chip Initialization
VDD1/VSS1
VDD/VSS
43(36)/40(33)
–
Logic power supply pin. VDD should be tied to
+5 V during programming.
NOTE:
Parentheses indicate pin number for 42-SDIP-600 package.
Table 19-2. Comparison of S3F94A5 and S3C94A5 Features
Characteristic
S3F94A5
S3C94A5
Program memory
16K-byte flash ROM
16K-byte mask ROM
Operating voltage (V DD)
2.0 V to 5.5 V
2.0 V to 5.5 V
FLASH MCU programming
mode
VDD = 5 V, VPP (TEST) = 12.5 V
Programmability
User program multi time
19-4
–
Programmed at the factory
S3C94A5/F94A5
S3F94A5 FLASH MCU
OPERATING MODE CHARACTERISTICS
When 12.5 V is supplied to the VPP (TEST) pin of the S3F94A5, the Flash ROM programming mode is entered. The
operating mode (read, write, or read protection) is selected according to the input signals to the pins listed in Table
19-3 below.
Table 19-3. Operating Mode Selection Criteria
VDD
VPP(TEST)
REG/nMEM
Address
(A15–A0)
R/W
5V
5V
0
0000H
1
Flash ROM read
12.5 V
0
0000H
0
Flash ROM program
12.5 V
0
0000H
1
Flash ROM verify
12.5 V
1
0E3FH
0
Flash ROM read protection
NOTE:
Mode
"0" means Low level; "1" means High level.
19-5
S3F94A5 FLASH MCU
S3C94A5/F94A5
Table 19-4. D.C. Electrical Characteristics
(TA = –25 °C to + 85 °C, VDD = 2.0 V to 5.5 V)
Parameter
Supply current (1)
Symbol
IDD1
IDD2
IDD3(2)
Conditions
Min
Typ
Max
Unit
–
6.0
18.0
mA
Run mode:
VDD = 5 V ± 10%
12.0 MHz
Crystal oscillator
C1 = C2 = 22pF
4.19 MHz
2.5
6.0
VDD = 3 V ± 10%
8.0 MHz
2.5
5.0
4.19 MHz
1.5
3.0
Idle mode:
VDD = 5 V ± 10%
12.0 MHz
1.5
4.0
Crystal oscillator
C1 = C2 = 22pF
4.19 MHz
1.0
2.0
VDD = 3 V ± 10%
8.0 MHz
0.5
1.6
4.19 MHz
0.4
0.8
0.5
3
0.3
2
–
10
Stop mode; VDD = 5 V ± 10%
µA
TA = 25°C
Stop mode; VDD = 5 V ± 10%
TA = 25°C
TA = –25°C to + 85°C
NOTES:
1. Supply current does not include current drawn through internal pull-up resistors and ADC.
2. IDD3 is current when main clock oscillation stops.
3.
Every values in this table is measured when bits 4 -3 of the system clock control register (CLKCON.4–.3) is set to 11B.
19-6
S3C94A5/F94A5
S3F94A5 FLASH MCU
Instruction Clock
fx (oscillation frequency)
3 MHz
12 MHz
2 MHz
8 MHz
1 MHz
4 MHz
6.25 kHz
400 kHz
1
2
3
4
2.7
5
6
7
5.5
Supply Voltage (V)
Instruction Clock = 1/4n x oscillator frequency (n = 1, 2, 8, 16)
Figure 19-3. Operating Voltage Range
19-7
S3C94A5/F94A5
20
DEVELOPMENT TOOLS
DEVELOPMENT TOOLS
OVERVIEW
Samsung provides a powerful and easy-to-use development support system in turn key form. The development
support system is configured with a host system, debugging tools, and support software. For the host system, any
standard computer that operates with MS-DOS as its operating system can be used. One type of debugging tool
including hardware and software is provided: the sophisticated and powerful in-circuit emulator, SMDS2+, for S3C7,
S3C8, S3C9 families of microcontrollers. The SMDS2+ is a new and improved version of SMDS2. Samsung also
offers support software that includes debugger, assembler, and a program for setting options.
SHINE
Samsung Host Interface for In-Circuit Emulator, SHINE, is a multi-window based debugger for SMDS2+. SHINE
provides pull-down and pop-up menus, mouse support, function/hot keys, and context-sensitive hyper-linked help. It
has an advanced, multiple-windowed user interface that emphasizes ease of use. Each window can be sized, moved,
scrolled, highlighted, added, or removed completely.
SAMA ASSEMBLER
The Samsung Arrangeable Microcontroller (SAM) Assembler, SAMA, is a universal assembler, and generates object
code in standard hexadecimal format. Assembled program code includes the object code that is used for ROM data
and required SMDS program control data. To assemble programs, SAMA requires a source file and an auxiliary
definition (DEF) file with device specific information.
SASM86
The SASM86 is an relocatable assembler for Samsung's S3C9-series microcontrollers. The SASM86 takes a source
file containing assembly language statements and translates into a corresponding source code, object code and
comments. The SASM86 supports macros and conditional assembly. It runs on the MS-DOS operating system. It
produces the relocatable object code only, so the user should link object file. Object files can be linked with other
object files and loaded into memory.
HEX2ROM
HEX2ROM file generates ROM code from HEX file which has been produced by assembler. ROM code must be
needed to fabricate a microcontroller which has a mask ROM. When generating the ROM code (.OBJ file) by
HEX2ROM, the value “FF” is filled into the unused ROM area up to the maximum ROM size of the target device
automatically.
TARGET BOARDS
Target boards are available for all S3C9-series microcontrollers. All required target system cables and adapters are
included with the device-specific target board.
20-1
DEVELOPMENT TOOLS
S3C94A5/F94A5
IBM-PC AT or Compatible
RS-232C
SMDS2+
Target
Application
System
PROM/OTP Writer Unit
RAM Break/Display Unit
BUS
Probe
Adapter
Trace/Timer Unit
SAM8 Base Unit
Power Supply Unit
POD
TB94A5
Target
Board
EVA
Chip
Figure 20-1. SMDS Product Configuration (SMDS2+)
20-2
S3C94A5/F94A5
DEVELOPMENT TOOLS
TB94A5 TARGET BOARD
The TB94A5 target board is used for the S3C94A5 microcontroller. It is supported by the SMDS2+ development
system.
TB94A5
To User_V CC
OFF
REV.1
'2004.06.14
ON
STOP
R5
R4
VCC
C1
D1
R1
B1
+
IDLE
+
RESET
U2
R7
Smart Option
25
SW1 AR1
GND
B2
R8
C8 +
C7
20
40
30
20
10
J101
42SDIP
1
160
CN1
160 QFP
S3E94A0
EVA Chip
60
140
1
44
5
5
40
10
35
15
30
20
25
22
23
35
70
B3
42
40
150
50
10
1
J102
44QFP
130
10
80
30
90
100 110
120
15
1
25
51
76 26
R11
R12
C12
21
22
C14
EXTTRG1
EXTTRG2
R9
R10
C11
SMDS2
SMDS2+
Figure 20-2. TB94A5 Target Board Configuration
20-3
DEVELOPMENT TOOLS
S3C94A5/F94A5
Table 20-1. Power Selection Settings for TB94A5
"To User_V CC"
Operating Mode
Comments
Settings
To User_VCC
Off
On
TB94A5
VCC
Target
System
VSS
The SMDS2/SMDS2+ supplies
VCC to the target board
(evaluation chip) and the target
system.
VCC
SMDS2/SMDS2+
To User_VCC
Off
On
TB94A5
External
VCC
VSS
VCC
Target
System
The SMDS2/SMDS2+ supplies
VCC only to the target board
(evaluation chip). The target
system must have its own
power supply.
SMDS2/SMDS2+
NOTE:
The following symbol in the "To User_VCC" Setting column indicates the electrical short (off) configuration:
Table 20-2. Smart Option Switch Settings for TB94A5
"Smart Opting" Settings
Smart Option
ON: "0"
003FH.2
003FH.1
003FH.0
OFF: "1"
20-4
Comments
The Smart Option is selected by this switch.
For example the main oscillator is selected as internal RC oscillation if
the switch 003FH.2/003FH.1/003FH.0 is set like this
"ON/ON/OFF(001b)", respectively.
Refer to the Smart Option of Chapter 2. Address Spaces.
S3C94A5/F94A5
DEVELOPMENT TOOLS
SMDS2+ SELECTION (SAM8)
In order to write data into program memory that is available in SMDS2+, the target board should be selected to be for
SMDS2+ through a switch as follows. Otherwise, the program memory writing function is not available.
Table 20-3. The SMDS2+ Tool Selection Setting
Setting
SMDS2
Operating Mode
SMDS2+
R/W
R/W
SMDS2+
Target
Board
Table 20-4. Using Single Header Pins as the Input Path for External Trigger Sources
Target Board Part
Comments
Connector from
External Trigger
Sources of the
Application System
External
Triggers
Ch1
Ch2
You can connect an external trigger source to one of the two external
trigger channels (CH1 or CH2) for the SMDS2+ breakpoint and trace
functions.
IDLE LED
The Yellow LED is ON when the evaluation chip (S3E94A0) is in idle mode.
STOP LED
The Red LED is ON when the evaluation chip (S3E94A0) is in stop mode.
20-5
DEVELOPMENT TOOLS
S3C94A5/F94A5
J101
42-SDIP
P1.6
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
AVREF
VSS
P3.0
P3.1
P3.2
P3.3
P3.4
P3.5
P4.0
P4.1
P4.2
P4.3
P4.4
P4.5
NC
NC
NC
NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
43
44
45
46
J102
44-QFP
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
50
49
48
47
P1.5
P1.4
P1.3
P1.2
P1.1
P1.0
USER_V CC
NC
NC
VSS
DEMO_RSTB
VSS
P5.6
P5.5
P5.4
P5.3
P5.2
P5.1
P5.0
P4.7
P4.6
NC
NC
NC
NC
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
AVREF
VSS
P3.0
P3.1
P3.2
P3.3
P3.4
P3.5
USER_VCC
VSS
NC
NC
NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
45
46
47
Figure 20-3. Connectors (J101, J102) for TB94A5
20-6
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
50
49
48
P1.0
USER_VCC
NC
NC
VSS
DEMO_RSTB
VSS
P5.6
P5.5
P5.4
P5.3
P5.2
P5.1
P5.0
P4.7
P4.6
P4.5
P4.4
P4.3
P4.2
P4.1
P4.0
NC
NC
NC
S3C94A5/F94A5
DEVELOPMENT TOOLS
Target Board
Target System
J101
50-Pin DIP Connector
1
J101
42
1
42
21
22
Target Cable for Connector
Part Name: AP42SD
Order Code: SM6538
21
22
Figure 20-4. S3C94A5 Probe Adapter for 42-SDIP Package
Target Board
Target System
J102
44
1
44
22
23
Target Cable for 50-pin Connector
Part Name: AP50D-A
Order Code: SM6305
22
23
50-Pin Connector
50-Pin Connector
1
J102
Figure 20-5. S3C94A5 Probe Adapter for 44-QFP Package
20-7
S3C9 Series Mask ROM Order Form
Product description:
Device Number: S3C9__________-_________ (write down the ROM code number)
Product Order Form:
Package
Pellet
Wafer
Package Type:
__________
Package Marking (Check One):
Standard
Custom A
Custom B
(Max 10 chars)
SEC
(Max 10 chars each line)
@ YWW
Device Name
@ YWW
Device Name
@ YWW
@ : Assembly site code, Y : Last number of assembly year, WW : Week of assembly
Delivery Dates and Quantities:
Deliverable
Required Delivery Date
Quantity
Comments
–
Not applicable
See ROM Selection Form
ROM code
Customer sample
Risk order
See Risk Order Sheet
Please answer the following questions:
F
For what kind of product will you be using this order?
New product
Upgrade of an existing product
Replacement of an existing product
Other
If you are replacing an existing product, please indicate the former product name
(
F
)
What are the main reasons you decided to use a Samsung microcontroller in your product?
Please check all that apply.
Price
Product quality
Features and functions
Development system
Technical support
Delivery on time
Used same micom before
Quality of documentation
Samsung reputation
Mask Charge (US$ / Won):
____________________________
Customer Information:
Company Name:
Signatures:
___________________
________________________
(Person placing the order)
Telephone number
_________________________
__________________________________
(Technical Manager)
(For duplicate copies of this form, and for additional ordering information, please contact your local
Samsung sales representative. Samsung sales offices are listed on the back cover of this book.)
S3C9 Series
Request for Production at Customer Risk
Customer Information:
Company Name:
________________________________________________________________
Department:
________________________________________________________________
Telephone Number:
__________________________
Date:
__________________________
Fax: _____________________________
Risk Order Information:
Device Number:
S3C9________-________ (write down the ROM code number)
Package:
Number of Pins: ____________
Intended Application:
________________________________________________________________
Product Model Number:
________________________________________________________________
Package Type: _____________________
Customer Risk Order Agreement:
We hereby request SEC to produce the above named product in the quantity stated below. We believe our risk order
product to be in full compliance with all SEC production specifications and, to this extent, agree to assume
responsibility for any and all production risks involved.
Order Quantity and Delivery Schedule:
Risk Order Quantity:
_____________________ PCS
Delivery Schedule:
Delivery Date (s)
Signatures:
Quantity
_______________________________
(Person Placing the Risk Order)
Comments
_______________________________________
(SEC Sales Representative)
(For duplicate copies of this form, and for additional ordering information, please contact your local
Samsung sales representative. Samsung sales offices are listed on the back cover of this book.)
S3F9 Series MTP Factory Writing Order Form (1/2)
Product Description:
Device Number:
S3F9________-________ (write down the ROM code number)
Product Order Form:
Package
Pellet
If the product order form is package:
Wafer
Package Type:
_____________________
Package Marking (Check One):
Standard
Custom A
Custom B
(Max 10 chars)
SEC
(Max 10 chars each line)
@ YWW
Device Name
@ YWW
Device Name
@ YWW
@ : Assembly site code, Y : Last number of assembly year, WW : Week of assembly
Delivery Dates and Quantity:
ROM Code Release Date
Required Delivery Date of Device
Quantity
Please answer the following questions:
F
What is the purpose of this order?
New product development
Upgrade of an existing product
Replacement of an existing microcontroller
Other
If you are replacing an existing microcontroller, please indicate the former microcontroller name
(
F
)
What are the main reasons you decided to use a Samsung microcontroller in your product?
Please check all that apply.
Price
Product quality
Features and functions
Development system
Technical support
Delivery on time
Used same micom before
Quality of documentation
Samsung reputation
Customer Information:
Company Name:
Signatures:
___________________
________________________
(Person placing the order)
Telephone number
_________________________
__________________________________
(Technical Manager)
(For duplicate copies of this form, and for additional ordering information, please contact your local
Samsung sales representative. Samsung sales offices are listed on the back cover of this book.)
S3F94A5 MTP Factory Writing Order Form (2/2)
Device Number:
S3F_________-________ (write down the ROM code number)
Customer Checksums:
_______________________________________________________________
Company Name:
________________________________________________________________
Signature (Engineer):
________________________________________________________________
Read Protection (1):
Yes
No
Please answer the following questions:
F
Are you going to continue ordering this device?
Yes
No
If so, how much will you be ordering?
F
_________________ PCS
Application (Product Model ID: _______________________)
Audio
Video
Telecom
LCD Databank
Caller ID
LCD Game
Industrials
Home Appliance
Office Automation
Remocon
Battery Charger
Other
Please describe in detail its application
__________________________________________________________________________
NOTES:
1. Once you choose a read protection, you cannot read again the programming code from the EPROM.
2. OTP Writing will be executed in our manufacturing site.
3. The writing program is completely verified by a customer. Samsung does not take on any responsibility for errors
occurred from the writing program.
(For duplicate copies of this form, and for additional ordering information, please contact your local