CAR RADIO DIAGNOSTIC PROCESSOR
■
■
■
■
■
■
■
■
■
■
■
■
■
WIDE OPERATING VOLTAGE RANGE
ST-BY FUNCTION (C-MOS)
LOW QUIESCENT ST-BY CURRENT
CONSUMPTION
I2C BUS INTERFACE WITH 2 EXTERNALLY
SELECTABLE ADDRESSES
UP TO 5 BTL EQUIVALENT INPUTS FOR
FAULT DETECTION IN THE AUDIO
CHANNELS
- short to GND
- short to Vs
- short across the load (at turn-on)
- open load (at turn-on)
2 AUX INPUTS FOR FAULT DETECTION IN
THE ANTENNA AND BOOSTERS SUPPLY
LINE- short to GND- open load
WARNING PIN FUNCTION (interrupt facility)
ACTIVATED IN THE FOLLOWING
CONDITION:
- audio channel shorted to VS
- audio channel shorted to GND
- aux input shorted to GND
NOISE FREE DIAGNOSTICS OPERATION
PROTECTORS
LOAD DUMP VOLTAGE
OPEN GND
REVERSED BATTERY
ESD
MULTIPOWER BCD TECHNOLOGY
SO-24
ORDERING NUMBER: TDA7476
DESCRIPTION
The car radio diagnostic processor is an interface
chip in BCD Technology intended for car radio applications. It is able to detect potential faults coming
from any misconnection in the car radio or in the harness when installing the set.
The device is able to reveal any fault in the loudspeaker lines and in the antenna and booster supply
lines, providing a proper output signal (I2C bus compatible) in order to disable the ICs under fault and/or
to alert the micro-controller by means of warning
messages.
PIN CONNECTION (Top view)
GND
1
24
CH5-
SDA
2
23
CH5+
SCL
3
22
CH4+
ADD
4
21
CH4-
W
5
20
CH3-
AUX1 OUT
6
19
CH3+
AUX1 IN
7
18
CH2+
AUX2 IN
8
17
CH2-
AUX2 OUT
9
16
CH1-
5V
10
15
CH1+
ST-BY
11
14
T-CAP
VS
12
13
CSR
D97AU570A
April 2001
1/19
TDA7476
BLOCK DIAGRAM & APPLICATION CIRCUIT
24
2
SDA
3
SCL
2
I C
4
ADD
23
INTERFACE
22
21
12
VS
C3
10µF
19
5
CURRENT
FORCING
&
COMPARATORS
11
10
14
5V
REF
13
CH3
18
DELAY
R4
10KΩ
ST-BY
SW1
CH4
20
C2
100nF
W
R3
10KΩ
CH5
VOLTAGE REGULATOR
&
TEST SIGNAL GENERATOR
17
CH2
16
15
CH1
6
OUT
RSENS1
7
C1
10∝F
CT
IN
RCS
8
IN
RSENS2
R5 51Ω
DIG-GND
1
9
N°
Pin
1
GND
Ground
2
SDA
Dta line
3
SCL
Clock line
4
ADD
Address select
5
W
6
AUX1 OUT
7
AUX1 IN
AUX1 input
8
AUX2 IN
AUX2 input
9
AUX2 OUT
AUX2 output
10
5V
5V-Regulator
11
ST-BY
12
VS
13
CSR
14
T-CAP
15/16
CH1+/CH1-
Audio output - Channel 1
17/18
CH2-/CH2+
Audio output - Channel 2
19/20
CH3+/CH3-
Audio output - Channel 3
21/22
CH4-/CH4+
Audio output - Channel 4
23/24
CH5+/CH5-
Audio output - Channel 5
2/19
Description
Warning
AUX1 output
Stand-by
Supply Voltage
Current setting resistor
Timing capacitor
AUX2
OUT
D96AU499A
PIN FUNCTION
AUX1
TDA7476
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
Vop
Operating Supply Voltage
18
V
Vs
DC Supply Voltage
28
V
Peak Supply Voltage t = 50ms
40
V
Total Power Dissipation Tcase = 25°C
1.5
W
-40 to 150
°C
Vpeak
Ptot
Tstg; T‘c-
Storage and Junction Temperature
VSB
Stand-by Pin Voltage
6
V
VSDA
SDA Pin Voltage
6
V
VSCL
SCL Pin Voltage
6
V
VADD
ADD Pin Voltage
6
V
VCH
CH+ or CH- Pin Voltage
min (*) (VS +10, 25)
(*) Minimum value between VS+10V and 25V.
THERMAL DATA
Symbol
RTh j-amb
Parameter
Thermal resistance junction to ambient
Max.
Value
Unit
85
°C/W
ELECTRICAL CHARACTERISTICS
(Vs = 14.4V; Tamb = 25°, unless otherwise specified.)
Symbol
VSBIN
Parameter
Test Condition
Iq
Typ.
Stand-By IN Threshold
VSBOUT Stand-By OUT Threshold
ISB
Min.
Max.
Unit
1.5
V
3.5
Stand-By Current Consumption
Stand-By Voltage Pin = 1.5V
Total Quiescent Current
Total quiescent Current with
TDA7476 not addressed
V
100
5
µA
mA
AUDIO INPUTS CH1, CH2, CH3, CH4, CH5 - TURN ON DIAGNOSTIC
Pgnd
Pvs
Pnop
Short to GND det. (below this
limit, the Audio Output is
considerd in Short Circuit to
GND)
Short to Vs det. (above this limit,
the Audio Output is considered in
Short Circuit to Vs)
Normal operation thresholds.
(Within these limits, the Audio
Output is considered without
faults)
Power amplifier in st-by condition
0.8
Vs-0.6
1.2
V
V
Vs-1.2
V
3/19
TDA7476
ELECTRICAL CHARACTERISTICS (continued)
(Vs = 14.4V; Tamb = 25°, unless otherwise specified.)
Symbol
Parameter
Test Condition
Min.
Lsc
Shorted Load det. (voltage across
the Audio Outputs). Below this
limit the load is considered
shorted.
Power amplifier in st-by condition
Lop
Open Load det. (voltage across
the Audio Outputs). Above this
limit the load is considered open.
550
Lnop
Normal load det. (Voltage across
the Audio Output). Within these
limits the load resistance is
considered normal.
22
Typ.
Max.
Unit
5
mV
mV
220
mV
AUX INPUTS AUX1, AUX2 - TURN ON DIAGNOSTIC
Agnd
Short to GND det. (voltage across
the sensing resistor). Above this
limit the AUX pin is considered in
Short Circuit to GND.
Aol
Open load det. (voltage across
the sensing resistor). Below this
limit the Aux pin is considered in
Open Load condition.
Anop
Normal Operation det. (Voltage
across the sensing resistor).
Within these limits the load
resistance connected to the Aux
pin is considered correct.
High side driver ON
0.85
0.125
V
0.085
V
0.5
V
0.8
V
AUDIO INPUTS - PERMANENT DIAGNOSTIC
Pgnd
Short to GND det. (below this
limit, the Audio Output is
considered in Short Circuit to Vs)
This condition must be true for a
time higher than Tdel
Pvs
Short to Vs det. (above this limit
the Audio Output is considered in
Short Circuit to Vs) This condition
must be true for a time higher
than Tdel
Pnop
Power amplifier ON
Vs-0.6
Normal operation thresholds.
(Within these limits, the Audio
Output is considered without
faults)
1.2
V
Vs-1.2
V
AUX INPUTS - PERMANENT DIAGNOSTIC
Agnd
4/19
Short to GND det. (above this
limit, the Audio Output is
considered in Short Circuit to Vs)
This condition must be true for a
time higher than Tdel
High side driver ON
0.85
V
TDA7476
ELECTRICAL CHARACTERISTICS (continued)
(Vs = 14.4V; Tamb = 25°, unless otherwise specified.)
Symbol
Parameter
Aol
Open load det. (voltage across
the sensing resistor. Below this
limit the Aux pin is considered in
Open Load condition)This
condition must be true for a time
higher than Tdel
Anop
Normal Operation det. (Voltage
across the sensing resistor.
Within these limits the load
resistance connected to the Aux
pin is considered correct)
Test Condition
Min.
Typ.
High side driver ON
0.125
Max.
Unit
0.085
V
0.5
V
PERMANENT DIAGNOSTIC - ACQUISITION TIME DELAY
Tdel
Acquisition time delay - The fault
is considered true if the fault
condition are present for more
than Tdel without interruption
2
s
PERMANENT DIAGNOSTIC - WARNING PIN
Vsat
Saturation voltage on pin 5
Sink Current at Pin 5 = 1mA
1
V
1.5
V
5
V
ADDRESS SELECT
VADD
Voltage on pin 4
Address 0100010X
Address 0100011X
3
I2C BUS INTERFACE
fSCL
Clock Frequency
400
KHz
VIL
Input Low Voltage
1.5
V
VIH
Input High Voltage
VSAT
Sat Voltage at pin 2
3
V
Sink Current at Pin 2 = 5mA
WORKING PRINCIPLES
Turn-on diagnostic - CH1, CH2, CH3, CH4, CH5 Shorted load/open load detection
■ To detect a short across the load or an open
load, a subsonic current pulse is generated. The
information related to the status of the outputs is
measured and memorized at the top of the
current pulse (tm in fig.1). The current is
sourced by the positive pins (CH1+,...CH5+)
and it is sunk by the corresponding negative
pins (CH1-,...CH5-).
1.5
V
Figure 1.
I(mA)
ISOURCE
ISINK
tm
D97AU571
ts
t(ms)
5/19
TDA7476
■
Isink and Isource are depending on the external resistor Rcs. The minimum allowed value for Rcs is
1.65KOhm. The relationship among Isink, Isource and Rcs is the following:
Isink = (3.3/Rcs) · 11
Isource = 1.5 · Isink
■
On bridge (or bridge equivalent) devices if there is no short circuit to GND or to Vs, Isource goes into
saturation mode (for Vout > 3V), and in the load flows Isink. As the turn-on diagnostic thresholds are
fixed, it is possible to calculate the ranges of loudspeaker resistance in which short circuit (S.C.), normal
operation and open load are detected as following:
S.C. across Load
0Ω
x
R1
Normal Load
R2
x
Open Load
R3
R4
infinite
D01AU1256
L sc ,max
Ls c,max
R1 = ------------------ = ------------------- ⋅ R cs
36.3
I sin k
L nop ,min
L no p,min
- = ---------------------- ⋅ R c s
R2 = --------------------36.3
I sin k
L no p,max
Lno p,max
- = ----------------------- ⋅ R c s
R3 = ---------------------36.3
I sin k
L op, min
L op ,max
R3 = ------------------- = -------------------- ⋅ R cs
36.3
I sin k
where Lsc, Lnop, Lop as specified in the ELCTRICAL CHARACTERISTICS.
For example, here below are two cases, with Rcs = 3.3KOhm and Rcs = 1.8KOhm..
S.C. across Load
0Ω
0.45Ω
S.C. across Load
0Ω
x
0.24Ω
Normal Operation
2Ω
x
20Ω
Normal Operation
1.1Ω
x
11Ω
Open Load
50Ω
x
infinite
Open Load
27Ω
infinite
D96AU500A
The exact values of the above mentioned resistive ranges may vary a little, depending on the power amplifier
used.
Turn-on diagnostic - CH1, CH2, CH3, CH4, CH5 - Short to GND and Vs.
To detect if there is short circuit to GND or Vs, the subsonic current pulse is exploited. The information related
to the status of the outputs are measured and memorized at the top of the current pulse (tm in fig.1). If no faults
are present, the pins connected to the audio outputs (CH1,..CH5) will reach about 3V.If one or more outputs are
shorted to GND, these voltages become lower than 3V.If one or more outputs are shorted to Vs, the output voltage increases over 3V.The fault status can be know by sensing the output voltages. The reason way voltage
threshold has been preferred instead of a current threshold to declare short circuit resistor ranges is two fold:
6/19
TDA7476
1) The amplifier can drain current in the resistive path of the short circuit, hence this current and consequently
the short circuit resistor cannot be determined with a sufficient level of accuracy.
2) The voltage difference between the car radio ground (reference) and the position of the chassis of the car
where the loudspeaker line is connected (due to an accidental short circuit) can be up to some hundreds of
mV. This does not permit a correct measure of the short circuit resistor.
Turn-on diagnostic - AUX1, AUX2
To detect if there is a short circuit to GND or an open load involving to the AUX output of the car radio, the voltage across a sensing resistor Rsens is detected.These output voltages (for example for the active antenna and
for the booster) are usually generated by high side drivers, but also voltage regulators with Vout >5V are admissible. The detection ranges can be set by adjusting the sensing resistors Rsens1 or Rsens2 as following:
S.C. to GND
x
I1
Normal Operation
x
I3
I2
Open Load
I4
D01AU1258
A O L,max
I 4 = --------------------R s en s
A nop ,min
I 3 = --------------------R s ens
A n op,max
I 2 = ----------------------R s en s
A gn d,min
I 1 = --------------------R sen s
Where AOL, Anop, Agnd are as specified in the ELECTRICAL CHARACTERISTICS.
For example, if Rsens = 5 Ohm, the following detection table will be operative :
S.C. to GND
x
Normal Operation
170mA 100mA
x
Open Load
25mA 17mA
D96AU503
Permanent diagnostic - CH1, CH2, CH3, CH4, CH5 - Short to GND and Vs
During the CAR-RADIO normal operation, to detect a short circuit to GND (or to Vs), the output voltages are
sensed. If one or more outputs stay at any voltage below 0.8V or over Vs-0.6V for more than 2 sec. (typ), the
warning pin is pulled down.The µP can address the TDA7476 to know the status.The subsonic current pulse is
activated also in this case. The fault is correctly detected if it remains until the memorization (tm in fig.1).In this
phase, faults regarding shorts across the load and open loads cannot be detected.
7/19
TDA7476
Permanent diagnostic - AUX1, AUX2 - Short circuit to GND and open load
■ The detection mode of the auxiliary inputs is equal to what is in place during turn-on, but the fault must
be lasting without interruption for more than 2 seconds.The warning pin is pulled down only in case of
short to GND. This is to avoid that this pin remains permanently to 0 level if one or both AUX outputs of
the car radio are unused.
Timing
■ From the byte "ADD1" to the byte "ADD2" the mP must wait a period Twait1(see Software Specification)
that is depending on the timing capacitor CT according to the following table (Twait1> tm, max):
CT (µF)
tm max (ms)
3.3
45
4.7
65
10
130
22
290
47
620
100
1300
Note: any (positive) spread of the capacitor value must be added. The relation to be used to determine Twait1
from the value of CT according to the following:
Twait1 > tm, max = (130 · CT/10µF)ms
■
After the byte "ADD2" the power amplifier can be switched-on. In some cases, the µP has to wait until
the current pulse is finished (Twait2). This time (ts in fig.1) is given by:
Twait2 > ts, max = (140 · CT/10µF)ms
For bridge or bridge equivalent devices (figg.5,6), Ct = 10µF will be enough.
TURN-ON DIAGNOSTIC - THRESHOLDS
CH1, CH2, CH3, CH4, CH5
■ Output voltage during test. (The power amplifier must be in ST-BY mode).
S.C. to GND
0V
■
x
0.8V
Normal Operation
1.2V
x
VS-1.2
S.C. to Vs
VS-0.6V
Voltage across the load during test. (The power amplifier must be in ST-BY mode).
S.C. across Load
0V
5mV
x
Normal Operation
22mV
220mV
x
Open Load
550mV
D97AU631A
■
VS
D96AU502B
VS
Note: some faults can mask others if they are present at the same moment on the same channel:
- If there is a short to GND and an open load on the same channel, the TDA7476 gives information only
about one of them, depending on the wire on which the short circuit is present.
- The short circuit to GND masks any short circuit across the load.
- The short circuit to Vs masks any short or open load.
8/19
TDA7476
The following table shows the result pointed out by TDA7476 when multiple misconnections are present:
ACTUAL FAULTS
POINTED OUT FAULT
S.C. CH+ to GND + OPEN LOAD
S.C. to GND
S.C. CH(*) to GND + S.C. ACROSS LOAD
S.C. to GND
S.C. CH- to GND + OPEN LOAD
OPEN LOAD
S.C. CH(*) to VS + OPEN LOAD
S.C. to VS
S.C. CH(*) to VS + S.C. ACROSS LOAD
S.C. to VS
S.C. CH+ to VS + S.C. CH- to GND
S.C. to VS
S.C. CH- to VS + S.C. CH+ to GND
S.C. to GND + S.C. to VS
(*) CH means CH+ or CH-
AUX1 - AUX2
■ Voltage across the sensing resistors
S.C. to GND
VS
x
0.85V
Normal Operation
0.5V
x
Open Load
85mV
125mV
0V
D97AU572A
■
The minimum voltage of the AUX IN pin to sense the open load condition is 2V.
■
The minimum voltage of the AUX IN pin to detect the short circuit to GND, by sensing the drop on the
resistors is 4.5V. If this voltage falls below 2V, the AUX in is considered short circuited to GND. From
2V to 4.5V the sensing circuit can detect a short circuit in both ways (by sensing across the resistor or
through the voltage between the AUX IN pin and GND).
PERMANENT DIAGNOSTIC - THRESHOLDS
CH1, CH2, CH3, CH4, CH5
■ The circuit will recognize as a fault condition any situation where the following short circuit voltages last
more than 2 sec (typ).
■
Output voltage
S.C. to GND
0V
x
0.8V
Normal Operation
1.2V
x
VS-1.2
S.C. to Vs
VS-0.6V
D97AU573B
VS
AUX1 - AUX2
■ The voltage across the resistors Rsens1 or Rsens2 is sensed. The circuit will recognize as a fault
condition any situation where the following voltages last more than 2sec (typ) in the region "S.C.to GND"
or "open load".
S.C. to GND
VS
0.85V
x
Normal Operation
0.5V
125mV
x
Open Load
85mV
0V
D97AU574A
9/19
TDA7476
■
The minimum voltage of the AUX IN pins to sense the open load condition is 2V.
■
The minimum voltage of the AUX IN pin to detect the short circuit to GND by sensing drop on the resistor
is 4.5V. If this voltage is below 2V, the AUX line is considered short circuited to GND. From 2V to 4.5V
the sensing circuit can detect a short circuit in both ways (by sensing across the resistor or through the
voltage between the AUX IN pin and GND).
I2C BUS INTERFACE
Data transmission from microprocessor to the TDA7476 and viceversa takes place through the 2 wires I2C BUS
interface, consisting of the two lines SDA and SCL (pull-up resistors to positive supply voltage must be connected).
Data Validity
As shown by fig. 2, the data on the SDA line must be stable during the high period of the clock. The HIGH and
LOW state of the data line can only change when the clock signal on the SCL line is LOW.
Start and Stop Conditions
As shown by fig. 3 a start condition is a HIGH to LOW transition of the SDA line while SCL is HIGH. The stop
condition is a LOW to HIGH transition of the SDA line while SCL is HIGH.
Byte Format
Every byte transferred to the SDA line must contain 8 bits. Each byte must be followed by an acknowledge bit.
The MSB is transferred first.
Acknowledge
The transmitter* puts a resistive HIGH level on the SDA line during the acknowledge clock pulse (see fig.4). The
receiver** the acknowledges has to pull-down (LOW) the SDA line during the acknowledge clock pulse, so that
the SDAline is stable LOW during this clock pulse.
* Transmitter
= master (µP) when it writes an address to the TDA7476
= slave (TDA7476) when the µP reads a data byte from TDA7476
** Receiver
= slave (TDA7476) when the µP writes an address to the TDA7476
= master (µP) when it reads a data byte from TDA7476
Figure 2. Data Validity on the I2CBUS
SDA
SCL
DATA LINE
STABLE, DATA
VALID
10/19
CHANGE
DATA
ALLOWED
D99AU1031
TDA7476
Figure 3. Timing Diagram on the I2CBUS
SCL
I2CBUS
SDA
D99AU1032
START
STOP
Figure 4. Acknowledge on the I2CBUS
SCL
1
2
3
7
8
9
SDA
MSB
START
ACKNOWLEDGMENT
FROM RECEIVER
D99AU1033
SOFTWARE SPECIFICATIONS
The TDA7476 is activated by turning-on the ST-BY pin (CMOS compatible). In this condition it waits for the
I2CBus addressing byte ADD1 (WRITE to TDA7476)
ADD1
S
010001A
0
ACK
STOP
This sequence (where the bit 0 of ADD1 is at 0 level) enables the acquisition routine and starts the single pulse
(containing infrasonic harmonics) for the test. During this period the data regarding all the outputs are memorized.After a period Twait1 that depends on the value of the timing capacitor (see Timing) the µP redirects the
TDA7476 by the byte ADD2.
ADD1
S
010001A
0
ACK
BYTE1
ACK
BYTE2
ACK
BYTE3
ACK
STOP
The byte ADD2 contains the bit 0 at 1 level. This enables the reading mode, TDA7476's. The 3 bytes with the
diagnostic information BYTE1, BYTE2, BYTE3 (READ FROM TDA7476) are now transmitted to the µP.
The address of TDA7476 is selected using pin ADD (pin 4) .
If ADD is connected to ground, then A = 0 and the TDA7476 address is 0100010X.
If ADD is connected to 5V, than A = 1 and the TDA7476 address is 0100011X
■ The TDA7476 provides two types of diagnostic information:
A) TURN-ON DIAGNOSTIC - The first time that the TDA7476 is addressed by I2CBus, the more complete set
of diagnostic information is activated:
- CH1, CH2, CH3, CH4, CH5
Short Circuit to GND
Short Circuit to Vs
Open Load (*)
Short Circuit across the load (*)
(*) Detected if the power amplifiers are in ST-BY condition.
- AUX1, AUX2
Short Circuit to GND (*)
Open Load (*)
(*) Detected if the high side drivers attached to the Aux outputs are ON.
Here following the turn-on diagnostic output bytes
11/19
TDA7476
READ BYTE 1
MSB
LSB
STATUS
D7
D6
D5
D4
D3
D2
D1
D0
X
X
X
X
1
1
X
0
CH1 short circuit to Vs
X
X
X
X
1
1
0
X
CH1 short circuit to GND
X
X
X
X
1
0
1
1
CH1 open load
X
X
X
X
0
1
1
1
CH1 short circuit across the load
1
1
X
0
X
X
X
X
CH2 short circuit to Vs
1
1
0
X
X
X
X
X
CH2 short circuit to GND
1
0
1
1
X
X
X
X
CH2 open load
0
1
1
1
X
X
X
X
CH2 short circuit across the load
READ BYTE 2
X
X
X
X
1
1
X
0
CH3 short circuit to Vs
X
X
X
X
1
1
0
X
CH3 short circuit to GND
X
X
X
X
1
0
1
1
CH3 open load
X
X
X
X
0
1
1
1
CH3 short circuit across the load
1
1
X
0
X
X
X
X
CH4 short circuit to Vs
1
1
0
X
X
X
X
X
CH4 short circuit to GND
1
0
1
1
X
X
X
X
CH4 open load
0
1
1
1
X
X
X
X
CH4 short circuit across the load
READ BYTE 3
X
X
X
X
X
X
1
0
AUX1 short circuit to GND
X
X
X
X
X
X
0
1
AUX1 open load
X
X
X
X
1
0
X
X
AUX2 short circuit to GND
X
X
X
X
0
1
X
X
AUX2 open load
1
1
X
0
X
X
X
X
CH5 short circuit to Vs
1
1
0
X
X
X
X
X
CH5 short circuit to GND
1
0
1
1
X
X
X
X
CH5 open load
0
1
1
1
X
X
X
X
CH5 short circuit across the load
When the µP reads correctly all the 3 bytes containing the mentioned information and gives the last acknowledge, the TDA7476 switches to the "permanent diagnostic operation"
B) PERMANENT DIAGNOSTIC
It can sense the following diagnostic information:
CH1, CH2, CH3, CH4, CH5
- Short Circuit to GND
- Short Circuit to Vs
Aux1, Aux2
- Short Circuit to GND (*)
- Open Load (*)
(*) Detected if the high side drivers attached to the Aux outputs are ON.
In this case the above conditions are not detected while the single infrasonic current pulse is present but before. The fault condition must be present for more than 2sec. (typ) and must be also true during the pulse,
where the data are memorized and then transmitted.The bytes from/to µP and TDA7476 are the same as
those in case of turn-on diagnostic (see above).
Here following is the permanent diagnostic output Data Bytes. The bits D7 and D6 of the first byte both stand at
0 level. This condition, although not possible during the turn-on diagnostic, can be useful to confirm that the
bytes are referred to the permanent diagnostic.
12/19
TDA7476
READ BYTE 1
MSB
LSB
STATUS
D7
D6
D5
D4
D3
D2
D1
D0
0
0
X
X
1
1
X
0
CH1 short circuit to Vs
0
0
X
X
1
1
0
X
CH1 short circuit to GND
0
0
X
X
1
1
1
1
0
0
X
X
1
1
1
1
0
0
X
0
1
1
X
X
CH2 short circuit to Vs
0
0
0
X
1
1
X
X
CH2 short circuit to GND
0
0
1
1
1
1
X
X
0
0
1
1
1
1
X
X
READ BYTE 2
1
1
X
X
1
1
X
0
CH3 short circuit to Vs
1
1
X
X
1
1
0
X
CH3 short circuit to GND
1
1
X
X
1
1
1
1
1
1
X
X
1
1
1
1
1
1
X
0
1
1
X
X
CH4 short circuit to Vs
1
1
0
X
1
1
X
X
CH4 short circuit to GND
1
1
1
1
1
1
X
X
1
1
1
1
1
1
X
X
READ BYTE 3
1
1
X
X
X
X
1
0
AUX1 short circuit to GND
1
1
X
X
X
X
0
1
AUX1 open load
1
1
X
X
1
0
X
X
AUX2 short circuit to GND
1
1
X
X
0
1
X
X
AUX2 open load
1
1
X
0
X
X
X
X
CH5 short circuit to Vs
1
1
0
X
X
X
X
X
CH5 short circuit to GND
1
1
1
1
X
X
X
X
1
1
1
1
X
X
X
X
Repetitive turn-on diagnostic
During the turn-on diagnostic, the TDA7476 can reveal false "short circuit across load" and/or false "open load"
due to noise sources such as door slams.
This problem can be solved doing more than one turn-on diagnostic routine. If the µP asks for N times the state
of the audio system, it has to consider a fault as really present only if it is detected in all the N turn-on diagnostic.As above explained, the first time the TDA7476 receivers the byte ADD1, it does the turn-on diagnostic; then
each time it is addessed with ADD1, it does the permanent diagnostic. This is not true if, when the µP sends for
the first time the byte ADD2, it does not send to the TDA7476 the acknowledge after it has received the byte
BYTE3. In this case, the TDA7476 does not switch from turn-on to permanent diagnostic mode so if it receives
again the byte ADD1 it works as it was the first time that it does the turn-on diagnostic. In order to do repetitive
turn-on diagnostic, the mP has to be programmed as following:
■ Step 1: the µP sends ADD1
START
■
■
ADD1
ACK
ACK
Step 2: the µP waits Twait1 seconds
Step 3: the µP sends ADD2, receives BYTE1, BYTE2, BYTE3, does not send the acknowlegde after
BYTE3
13/19
TDA7476
START
■
ADD2
ACK
BYTE1
ACK
BYTE2
ACK
BYTE3
STOP
Step 4: repeat Step1, Step2, Step3 while the second, third, fourth, ...turn-on diagnostic has to be done.
During the last turn-on diagnostic the µP sends ADD2, receives BYTE1, BYTE2, BYTE3, and sends
the acknowlegde after BYTE3
START
ADD2
ACK
BYTE1
ACK
BYTE2
ACK
BYTE3
ACK
STOP
In this way only after that the TDA7476 has done for N times the turn-on diagnostic, it switches from turn-on to
permanent diagnostic mode.From now the TDA7476 always does the permanent diagnostic.To save time when
the audio system is switched on, it is possible to do the repetitive turn-on diagnostic when the car-radio is turned
off. In this case the steps to follow to do the repetitive turn-on diagnostic are the following:
1- to switch off the TDA7476 connecting STBY pin to ground;
2- to wait T5V seconds (time necessary for the discharge of the capacitor). If C5V = 10µF then T5V = 20ms typ;
3- to switch on the TDA7476
4- to do the repetitive turn-on diagnostic as above described;
5- to turn off the TDA7476.
WARNING PIN
■ This is an open drain output pin that is activated when a fault condition is present for more than 2 sec
(TYP). The fault conditions related to the warning pin are as follows:
- AUX1, AUX2
Short to GND
- CH1, CH2, CH3, CH4, CH5:
Short Circuit to GND
Short Circuit to Vs
■
The purpose of this pin is to alert the µP and start with the permanent diagnostic routine only if faults
are present, thus avoiding CPU's waste of time.
14/19
TDA7476
APPLICATION NOTES
■ When single-ended devices are used and the application circuit is as shown in fig. 7,8, it is necessary
to use:
- a greater timing capacitor so that the time tm is high and the outputs of the amplifiers are able to rise over 1V;
- a resistor RCS 1.5 times higher than that used for the bridge amplifiers.
In this case, the loudspeaker resistance ranges in which short circuit, normal operation and open load
are detected will be as follows:
S.C. across Load
x
R1,SE
Normal Operation
R2,SE
x
R3,SE
Open Load
R4,SE
D01AU1257
L SC,max
L S C,max
R1 ,SE = -------------------- = --------------------- ⋅ R CS
54.45
I s ourc e
L no p,min
LS C,min
- = ---------------------- ⋅ R CS
R2 ,SE = ------------------54.45
I s ou rce
L n op,max
L n op ,max
- = ----------------------- ⋅ R CS
R3 ,SE = ---------------------54.45
I s ourc e
L op,min
L o p,min
= ------------------ ⋅ R CS
R4 ,SE = -----------------54.45
I so urce
For example, here below are two cases, with RCS = 4.7kOhm and RCS = 2.7kOhm.
S.C. across Load
0Ω
0.43Ω
S.C. across Load
0Ω
x
0.24Ω
Normal Operation
1.9Ω
x
19Ω
Normal Operation
1.1Ω
x
11Ω
Open Load
47Ω
x
infinite
Open Load
27Ω
infinite
D96AU501A
The exact values of the above mentioned resistive ranges may vary a little, depending on the power amplifier
used
In Permanent mode for single-ended devices as in fig. 7, 8 a short citcuit to ground is detected both when a
short to ground is really present and when the load is missing.
On single-ended devices as in figure 6, 8 if the loads are present then both in turn-on and in permanent diagnostic the fault present on one channel is pointed out for all the loads connected together.For example:
- see fig.8 if CH1+ is shorted to ground, the TDA7476 reveals a short to ground both for CH2 and for CH1.
- see fig.6 if CH1+ is shorted to ground, the TDA7476 detects a short circuit to ground for CH1, CH2, CH3, CH4.
About timing for the TDA7375, connected as in fig.7, Ct = 47µF if Cout = 1000µF, and Ct = 100µF if Cout =
2200µF.
If the circuit is as shown by fig. 8, the suggested values of Ct are as follows: Ct = 22µF if Cout = 1000µF,
Ct = 47µF if Cout = 2200µF.
15/19
TDA7476
■
To use the TDA7476 with a car-radio system which has less than five audio channel and less than two
auxiliary loads, it is necessary to take some cares:
- each pin CH± not used has to be fixed to 5V
- each pin AUX1IN, AUX1OUT, AUXIN2, AUX2OUT not used has to be fixed to a voltage equal or greater than 5V
The 5V voltage reference available on the chip (pin 10) is very useful to fix both CH± and AUX pins to
5V.
APPLICATION EXAMPLES WITH ST AUDIO POWER ICs
Figure 5. Quad Bridge Amplifiers
TDA7384, TDA7385, TDA7386, TDA7454
+
-
-
+
+
-
-
+
R
CH1+ CH2+ CH3+ CH4+ CH5+
CH5-
CH4-
CH3-
CH2-
CH1-
TDA7476
D97AU578A
Figure 6. TDA7451
TDA7451
+
-
-
+
+
-
-
+
R
CH1+ CH2+ CH3+ CH4+ CH5+
CH5-
TDA7476
D97AU577A
16/19
CH4-
CH3-
CH2-
CH1-
TDA7476
Figure 7. TDA7375 in S.E. mode with 4 output capacitors
TDA7375
COUT1
+
COUT2
-
+
COUT3
+
COUT4
-
+
R
CH1+ CH2+ CH3+ CH4+ CH5+
CH5-
CH4-
CH3-
CH2-
CH1-
TDA7476
D97AU575A
Figure 8. TDA7375 in S.E. mode with 2 output capacitors
TDA7375
COUT1
+
-
-
+
+
COUT2
-
+
R
CH1+ CH2+ CH3+ CH4+ CH5+
CH5-
CH4-
CH3-
CH2-
CH1-
TDA7476
D97AU576A
17/19
TDA7476
mm
DIM.
MIN.
TYP.
inch
MAX.
MIN.
TYP.
MAX.
A
2.35
2.65
0.093
0.104
A1
0.10
0.30
0.004
0.012
A2
2.55
0.100
B
0.33
0.51
0.013
0.0200
C
0.23
0.32
0.009
0.013
D
15.20
15.60
0.598
0.614
E
7.40
7.60
0.291
0.299
e
1.27
0,050
H
10.0
10.65
0.394
0.419
h
0.25
0.75
0.010
0.030
k
OUTLINE AND
MECHANICAL DATA
0° (min.), 8° (max.)
SO24
L
0.40
1.27
0.016
0.050
0.10mm
B
e
A
A2
h x 45˚
A1
K
A1
L
.004
H
Seating Plane
D
13
1
12
E
24
SO24
18/19
C
TDA7476
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject
to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not
authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is a registered trademark of STMicroelectronics
 2001 STMicroelectronics - All Rights Reserved
STMicroelectronics GROUP OF COMPANIES
Australia - Brazil - China - Finland - France - Germany - Hong Kong - India - Italy - Japan - Malaysia - Malta - Morocco - Singapore - Spain
- Sweden - Switzerland - United Kingdom - U.S.A.
http://www.st.com
19/19