tfs433b.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 433 B 1/5 ______________________________________________________________________________________________________ Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedances: input: output: 50 Ω 50 Ω Characteristics Remark: Reference level for the relative attenuation arel of the TFS 433 B is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 433,92 MHz without tolerance. The given values for the relative attenuation arel have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Variation/ Limitation ______________________________________________________________________________________________________ ae = amin max 3,5 dB Insertion loss 2,5 dB (Reference level) ______________________________________________________________________________________________________ fN Nominal frequency 433,92 MHz ______________________________________________________________________________________________________ fc Centre frequency 433,92 MHz ______________________________________________________________________________________________________ 8,5 MHz min 4 MHz BW 3 dB - bandwidth ______________________________________________________________________________________________________ Relative attenuation arel fN ..... fN ±2.0 MHz max 3.0 dB MHz ... fN ±100 MHz min 40 dB fN ± 25 MHz ... fN ±200 MHz min 60 dB fN ± 100 MHz min 60 dB fN - 10,7 ______________________________________________________________________________________________________ -32 ppm/K TCf Temperature coefficient of the frequency ______________________________________________________________________________________________________ Operating temperature range - 15 °C........+ 60 °C ______________________________________________________________________________________________________ Generated Sabah (05.05.00) Checked / approved : ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs433b.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 433 B 2/5 ______________________________________________________________________________________________________ Construction and pin connection S433B K8 50 Ω test circut 1 IN C1 4 SAW OUT 2,3 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs433b.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 433 B 3/5 ______________________________________________________________________________________________________ Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs433b.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 433 B 4/5 ______________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C air reflow temperature profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs433b.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 433 B 5/5 ______________________________________________________________________________________________________ History Version Reason of Changes Name Date 1.3 - improvement of Lyout - addition values for relative attenuation in passband Sabah 05.05.00 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.