VECTRON TFS433B

tfs433b.doc
version 1.3
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 433 B 1/5
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedances:
input:
output:
50 Ω
50 Ω
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 433 B is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the
3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 433,92 MHz without tolerance. The given values for
the relative attenuation arel have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature
coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Variation/ Limitation
______________________________________________________________________________________________________
ae = amin
max
3,5 dB
Insertion loss
2,5 dB
(Reference level)
______________________________________________________________________________________________________
fN
Nominal frequency
433,92 MHz
______________________________________________________________________________________________________
fc
Centre frequency
433,92 MHz
______________________________________________________________________________________________________
8,5 MHz
min 4 MHz
BW
3 dB - bandwidth
______________________________________________________________________________________________________
Relative attenuation
arel
fN
.....
fN ±2.0
MHz
max 3.0 dB
MHz ... fN ±100 MHz
min 40
dB
fN ± 25
MHz ... fN ±200 MHz
min 60
dB
fN ± 100
MHz
min 60
dB
fN - 10,7
______________________________________________________________________________________________________
-32
ppm/K
TCf
Temperature coefficient of the frequency
______________________________________________________________________________________________________
Operating temperature range
- 15 °C........+ 60 °C
______________________________________________________________________________________________________
Generated
Sabah (05.05.00)
Checked / approved :
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433b.doc
version 1.3
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 433 B 2/5
______________________________________________________________________________________________________
Construction and pin connection
S433B K8
50 Ω test circut
1
IN
C1
4
SAW
OUT
2,3
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433b.doc
version 1.3
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 433 B 3/5
______________________________________________________________________________________________________
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433b.doc
version 1.3
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 433 B 4/5
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
air reflow temperature profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433b.doc
version 1.3
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 433 B 5/5
______________________________________________________________________________________________________
History
Version
Reason of Changes
Name
Date
1.3
- improvement of Lyout
- addition values for relative attenuation in passband
Sabah
05.05.00
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.