VECTRON TFS70H21

TFS70H21.doc
version 1.3
VI TELEFILTER
Filter Specification
27.11.01
TFS 70H21
1/5
Measurement condition
Ambient temperature:
25 C
Input power level:
10 dBm
Terminating impedances *:
for input:
for output:
53,5
53,5
// -8,3 pF
// -8,4 pF
Remark:
Reference level for the relative attenuation arel of the TFS 70H21 is the minimum of the pass band attenuation a min. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 1 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the
reference frequency fc and the frequency response of the filter at the operating temperature. The frequency shift of the filter at the operating
temperature not included in the production tolerance scheme.
Data
typ. value
tolerance/limit
Insertion loss
(Reference level)
ae
17,5
dB
max.
Centre frequency
fc
70,0
MHz
70,0 ±
0,04
MHz
1 dB bandwidth
40 dB bandwidth
BW
BW
MHz
MHz
min.
max.
0,16
1,00
MHz
MHz
max.
1
dB
dB
min.
min.
40
50
dB
dB
0,7
°
max.
3
3,0
µs
Relative attenuation
arel
fc 0,08 MHz .......fc + 0,08
fc ±
fc ±
0,17
0,93
MHz
0,50 MHz ....... fc ± 0,75 MHz
0,75 MHz ....... fc ±10,00 MHz
Phase linearity in PB
Group delay in PB
Group delay variation in PB
Temperature coefficient of frequency ( Tcf )
Frequency deviation of f c over temperature T:
Operating temperature
70
150
- 0.036
20,0
dB
°
-
ns
max. 300
ns
ppm/K²
2
2
fc(Hz) = Tcf(ppm/K ) x (T - TA) x fCAT (MHz)
- 20..... + 70
°C
Storage temperature range
- 25..... + 85
C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H21.doc
version 1.3
VI TELEFILTER
Filter Specification
Construction, pin configuration and 50
- matching network
(All dimensions in inch)
18
TFS 70H21
Date code:
M
N
P
....
11 10
TFS 70 H 21
27.11.01
2/5
Year+week
2000
2001
2002
P03
1 2
9
27,18 ±0,20
Pin Configuration
Input:
Input Return:
Output:
Output Return:
Ground:
18
1
10
9
2,11
ø0,45±0,05
1
2,54 ±0,20
20,32 ±0,20
50 Ohm test circuit
L1
10
18
TFS 70H21
IN
L2
OUT
1,2,9,11
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H21.doc
VI TELEFILTER
version 1.3
Filter Specification
TFS 70H21
27.11.01
3/5
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H21.doc
version 1.3
VI TELEFILTER
Filter Specification
27.11.01
TFS 70H21
4/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 1,5 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H21.doc
version 1.3
VI TELEFILTER
Filter Specification
27.11.01
TFS 70H21
5/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70H21.doc
VI TELEFILTER
version 1.3
Filter Specification
27.11.01
TFS 70H21
6/5
History
version
reason of changes
name
date
1.0
generate specification
Pfeiffer
15.08.2001
1.1
- new definition of insertion loss (minimum of the passband attenuation)
- terminated impedances added
- typical values added
Pfeiffer
21.08.2001
1.2
- pass band variation p-p deleted
Pfeiffer
14.09.2001
1.3
- package changed
Pfeiffer
27.11.2001
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.