VECTRON TFS70H33

File name: Tfs70H33.doc
Version 1.0
VI TELEFILTER
Filter specification
26.04.2002
TFS 70H33
1/5
1. Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances in fc * ) :
25
°C.
0
dBm.
for input:
for output:
151 Ω  - 21,3 pF.
147 Ω  - 21,5 pF.
2. Characteristics :
Remark: Reference level for the relative attenuation arel of the TFS 70H33 is the minimum of the pass band attenuation amin. The
minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of
the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency
Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency
shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data
Insertion loss (Reference level)
Centre frequency
ae
typ. value
tolerance / limit
24,5 dB
max.
fc at ambient temperature (fCTA)
70,0 MHz
70,00 ± 0,09 MHz
fc - 2 MHz ... fc + 2 MHz
0,3 dB
max.
0,8 dB
4,82 MHz
5,28 MHz
min.
min.
4,5 MHz
5,0 MHz
6,55 MHz
7,19 MHz
7,44 MHz
max.
7,5 MHz
-
max.
max.
max.
0,8 dB
1
dB
3
dB
dB
dB
min.
min.
40
50
dB
dB
max.
max.
90
5°
ns
p-p
Pass band ( PB ) :
Amplitude ripple in :
Bandwidth ( BW ) :
1
dB
3
dB
20
40
55
26
dB
fc ... fc ± 2,5 MHz
at ambient temperature TA
dB
dB
dB
Relative attenuation
arel
fc ... fc ± 2
MHz
fc ± 2
MHz ... fc ± 2,25 MHz
fc ± 2,25 MHz ... fc ± 2,5 MHz
fc ± 3,75 MHz ... fc ± 5
MHz
fc ± 5
MHz ... fc ± 30
MHz
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in PB :
Triple transit attenuation compared to main signal
Crosstalk
Temperature coefficient of frequency ( Tcf ) :
Frequency deviation of fc over temperature :
50...57
65
2,9 µs
35
ns
2 ° (r.m.s. 0,5 °)
54
60
dB
dB
- 19
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
Operating temperature range
Storage temperature range
- 25 °C ... + 80 °C
- 40 °C ... + 85 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Checked/Approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
W. Dunzow
Dr. Bert Wall
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs70H33.doc
Version 1.0
VI TELEFILTER
Filter specification
3. Construction and pin connection
TFS 70H33
26.04.2002
2/5
( all dimensions in mm)
22,5 Max.
13 max.
5,0 max.
5,6 max.
0,45 Dia.
7,62
2,54 ± 0,2
6x2,54 = 15,62
TFS
Date-code:
M
N
P
...
70H33
P22
Year+week
2000
2001
2002
...
Date-code
1
2
7
Pin
Pin
Pin
Pin
Pin
14
9
14
1
8
7
2, 9
Input
Input RF Return
Output
Output RF Return
Pakage Ground
8
4. 50 Ω matching network ( please refer to the application note for further details ) :
1 2
7
L1
50 Ω
L2
14
Scheme 1.
1 2
7
C2
C1
50 Ω
50 Ω
9 8
L1
Scheme 2.
L2
14
50 Ω
9 8
For final test we use scheme 1.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs70H33.doc
Version 1.0
VI TELEFILTER
Filter specification
26.04.2002
TFS 70H33
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions"
on page 4;
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs70H33.doc
Version 1.0
VI TELEFILTER
Filter specification
26.04.2002
TFS 70H33
4/5
6. Air reflow temperature conditions :
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs70H33.doc
VI TELEFILTER
Version 1.0
Filter specification
26.04.2002
TFS 70H33
5/5
7. History :
Version
Reason of changes
Name
Date
1.0
Generate filter specification.
Dunzow W.
26.04.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.