Tfs336 - Vectron International

Tfs336.doc
version 2.2
VI TELEFILTER
Filter Specification
26.07.2005
TFS 336
1/5
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedances
for input:
470 Ohm // -2,44 pF
for output:
470 Ohm // -2,44 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS336 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at
the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 336 MHz without tolerance. The given values
for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is
shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre
frequency fc.
Data
typ. value
Insertion loss
(Reference level)
ae
6
Nominal frequency
fN
-
Centre frequency
fC
3 dB bandwidth
BW
Relative attenuation
fN
... fN ±
fN ± 67,5 kHz ... fN ±
fN ± 200
fN ± 400
fN ± 600
fN ± 1,6
fN ± 3
fN - 120
kHz
kHz
kHz
MHz
MHz
MHz
Group delay distortion
... fN ±
fN
kHz ... fN ±
fN ± 50
max.
dB
kHz
kHz
MHz
MHz
MHz
MHz
GDD
50
kHz
75
kHz
Frequency inversion temperature
dB
-
-
min. ± 89
kHz
-
max
max
dB
dB
-
min
min
min
min
min
min
-
max ± 600
ns
max +1,7 / -3,1 µs
1,5
3,0
3
28
38
43
45
40
dB
dB
dB
dB
dB
dB
- 20 °C ... + 70 °C
Operating temperature range
Temperature coefficient of frequency
8
336,000 MHz
336,015 MHz
arel
67,5 kHz
89
kHz
... fN ± 400
... fN ± 600
... fN ±
1,6
... fN ±
3
... fN ± 25
... fN - 150
tolerance/limit
TC
ca. – 0,036
ppm/K²
+ 20 °C
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs336.doc
version 2.2
VI TELEFILTER
26.07.2005
Filter Specification
TFS 336
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
TFS336
M50
Datecode:
L
M
N
...
Year+week
1999
2000
2001
Pin 2:
Pin 7:
Pin 1,3,4,5,
6,8,9,10
Input
Output
Ground
DateCode
1
2
3
4
10
9
5
8
7
6
50 Ohm Test circuit 1
50 Ohm
L1
2
SAW
C1
L2
7
50 Ohm
C2
1, 3, 4, 5, 6, 8, 9, 10
50 Ohm Test circuit 2
50 Ohm
C1
C2
2
L1
50 Ohm
7
SAW
L2
1, 3, 4, 5, 6, 8, 9, 10
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs336.doc
version 2.2
VI TELEFILTER
26.07.2005
Filter Specification
TFS 336
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
:
:
:
16
± 0,3
4
± 0,1
1,5 + 0,1
E
:
F
:
G (min) :
1,75 ± 0,1
7,5 ± 0,1
0,6
P2
:
P1
:
D1(min) :
2
12
1,5
Ao
Bo
CT
7,6 ± 0,1
9,6 ± 0,1
13,5 + 0,1
:
:
:
2000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
± 0,1
± 0,1
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
:
W2 (max) :
330
16,4 +2
22,4
N (min)
:
60
C
:
12,8 ± 0,1
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the
right side of the tape.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs336.doc
version 2.2
VI TELEFILTER
26.07.2005
Filter Specification
TFS 336
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs336.doc
version 2.2
VI TELEFILTER
Filter Specification
26.07.2005
TFS 336
5/5
History
Version
Reason of Changes
Name
Date
2.1
Change limit line in frequency range of fN ± 3 MHz... fN ± 25 MHz from
50 dB to 45 dB.
Correct tape and reel information.
Add history.
Correct relative attenuation
Dr. Wall
15.12.2000
Strehl
26.07.2005
2.2
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.