VECTRON TFS200D

Tfs200D.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 200 D
1/4
______________________________________________________________________________________________________
1.
Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances in fc:
25
°C
0
dBm
for input:
for output:
592 Ω  -6,05 pF.
1131 Ω  -4,04 pF.
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 200D is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequence fc is the arithmetic mean value of the upper and lower frequencies at the
3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 200 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is
shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre
frequency fc.
Data
typ. value
Insertion loss (Reference level)
Nominal frequency
ae
18
200
200,02
dB
MHz
MHz
Pass band ( PB ) :
fN - 2,05 MHz ... fN + 2,05 MHz
Amplitude ripple in PB (p-p):
0,2...0,8
Bandwidth :
dB
max. 1,0
dB
at ambient temperature TA
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
Relative attenuation
fN
fN
fN
fN
max. 20
fN
Centre frequencyfc at ambient temperature (fCTA)
1
3
10
20
30
tolerance / limit
dB
±
±
±
±
4,47
5,30
6,52
7,43
7,90
MHz
MHz
MHz
MHz
MHz
min. 4,1
5,25 ± 0,25
MHz
MHZ
max. 10,0
MHz
arel
fN
......
2,05 MHz ....
2,75 MHz ....
5,0 MHz ....
20
MHz ....
fN
fN
fN
fN
fN
±
±
±
±
±
2,05
2,5
5,0
20
100
MHz
MHz
MHz
MHz
MHz
33...40
45...55
dB
dB
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in fN ... fN ± 2,5 MHz
0,94
µs
32
ns
1,9 ° (r.m.s. 0,4 °)
Triple transit attenuation compared to main signal :
Crosstalk :
Input/Output return loss with matching network (S11/S22):
44
55...65
4/6
Frequency inversion temperature ( To ) :
Temperature coefficient of frequency ( Tcf ) :
Frequency deviation of fc over temperature: * )
max. 1
max. 3
min. 3
min. 30
min. 40
dB
dB
dB
dB
dB
max 1,5
max. 100
µs
ns
dB
dB
dB
0 °C
-0,036
ppm/K²
∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fO (MHz)
Operating temperature range ( OTR ) :
- 20 °C ... + 70 °C
Storage temperature range :
- 40 °C ... + 85 °C
*) fO = fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Wadim Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs200D.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 200 D
2/4
______________________________________________________________________________________________________
3. Package, pin grid 2,54 mm
TFS
Pin 11 - Input.
Pin 12 - Input RF Return.
Pin 5 - Output.
Pin 6 - Output RF Return.
Pin 1-4, 7-10 PackageGround.
200D
tft
M25
Datecode:
K
L
M
Year+week
1998
1999
2000
.......
........
4. 50 Ω matching network ( see Application Note ):
1
L1
C1
2
3
4
12
5
Scheme 1
6
10
9
8
7
1
2
3
4
5
12
L1
C2
L2
11
L4
L3
6
11
L2
Scheme 2
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
10
9
8
7
Tfs200D.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 200 D
3/4
______________________________________________________________________________________________________
5. Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
6. Packing
Tape & Reel:
DIN IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
:
:
4 ± 0,1
Do
:
1,5 + 0,1
E
:
1,75 ± 0,1
F
:
11,5 ± 0,1
G (min) :
0,6
P2
2
P1
:
EMBOSSED CARRIER TAPE
24 ± 0,3
Po
:
1700
min 300 mm
min 500 mm
min 300 mm
Do
Po
P
2
Ko
t
E
A
o
F
D
± 0,1
CT
12 ± 0,1
D1(min) :
1,5
Ao
:
7,1 ± 0,2
Bo
:
13,9 ± 0,2
Ko
:
2,1 ± 0,1
T
:
0,3 ± 0,05
CT
:
21,5 ± 0,1
B
1
W
o
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
W1
W2 (max) :
N (min)
:
:
330
24,4 +2
30,4
:
60
C
C
:
13 +0,5/-0,2
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs200D.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 200 D
4/4
______________________________________________________________________________________________________
7. Air reflow temperature conditions :
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information