General Purpose Relays Industrial Relays Potter & Brumfield R10 Series Panel Plug-in Relay n 1 through 8 form C (CO) contact arrangement Broad range of coil options provides sensitivity ranging from 25 to 750mW n Various contacts switch from dry circuit to 7.5 amps n Many mounting and termination options n Typical applications Coin changers, audio equipment, elevators, traffic controls, ultrasonic test equipment, parking toll readers Approvals UL E29244; CSA LR15734 Technical data of approved types on request Contact Data Contact arrangement 1, 2, 3, 4, 6 and 8 Form C (CO) Rated voltage 120VAC Rated current 7.5A Contact material Ag, AgCdO, Au overlay Ag, AuPtAg Contact style Single or bifurcated crossbar Min. recommended contact load W type, AgCdO, single contact 300mA, 12VDC X type, AgCdO, single contact 300mA, 12VDC M type, AgCdO, bifurcated contact 300mA, 12VDC Y type, Ag, single contact 100mA, 12VDC Z type, Ag, bifurcated crossbar 1mA, 12VDC P type, Au overlay Ag, bifurcated crossbar dry circuit L type, AuPtAg, bifurcated crossbar dry circuit Initial contact resistance All AgCdO contact types 100mΩ All other contact materials and types 50mΩ Frequency of operation 360 ops./hr Contact ratings Type Load UL 508 W type, AgCdO, single contact 7.5A, 120VAC, resistive 7.5A, 28VDC, resistive 1/8HP, 120VAC, same polarity 1/6HP, 240VAC, same polarity X type, AgCdO, single contact 2A, 30VDC, resistive 5A, 120VAC, resistive 5A, 30VDC, resistive 1/20HP, 120VAC, same polarity 1/10HP, 240VAC, same polarity M type, AgCdO, bifurcated contact 5A, 120VAC, resistive 5A, 28VDC, resistive Y type, Ag, single contact 2A, 120VAC 2A, 28VDC 250VA, 250VAC 125VA, 125VAC Z type, Ag, bifurcated crossbar contact 3A, 120VAC 3A, 28VDC 2A, 30VDC 08-2011, Rev. 0811 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Cycles 100x103 6x103 100x103 6x103 6x103 6x103 6x103 30x103 100x103 6x103 6x103 100x103 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. R10 R10-R R10S R10-T Contact ratings (continued) Type Load Cycles UL 508 P type, Au overlay Ag, bifurcated crossbar contact 2A, 120VAC, resistive 100x103 3 A, 120 VAC, resistive 6x103 3 A, 30 VDC, resistive 100x103 L type, AuPtAg, bifurcated crossbar contact 500mA, 28VDC, resistive 6x103 Mechanical endurance 10x106 ops., except W type is 1x106 ops. Coil Data Coil voltage range Coil versions, DC coil Coil Rated Operate code voltage voltage VDC VDC V - standard DC voltage adjustment 1, 2 and 4 pole V10 3 2.25 V28 5 3.75 V52 6 4.5 V185 12 9 V700 24 18 V2.5K 48 36 V5.8K 72 54 V15.0K 115 86 6 pole V6 3 2.25 V16 5 3.75 V25 6 4.5 V90 12 9 V430 24 18 V1.5K 48 36 V3.5K 72 54 V9.0K 115 86 8 pole V5 3 2.25 V14 5 3.75 V20 6 4.5 V72 12 9 V350 24 18 V1.25K 48 36 V2.8K 72 54 V8.0K 115 86 3 to 115VDC 4.5mA to 20mA 6 to 115VAC Coil resistance Ω±10% Rated coil power mW 10 28 52 185 700 2500 5800 15000 900 900 900 900 900 900 900 900 6 16 25 90 430 1500 3500 9000 1,500 1,600 1,500 1,600 1,400 1,600 1,500 1,500 5 14 20 72 350 1250 2800 8000 1,800 1,800 1,800 2,000 1,700 1,900 1,900 1,700 All figures are given for coil without preenergization, at ambient temperature +23°C. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 General Purpose Relays Industrial Relays Potter & Brumfield R10 Series Panel Plug-in Relay (Continued) Coil versions, DC coil (continued) Coil Rated Operate code voltage voltage VDC VDC Q - special DC voltage adjustment 1 and 2 pole Q52 5 3.1 Q110 6 4.5 Q450 12 9.2 Q1.8K 24 17.4 Q7.5K 48 36.2 Q15.0K 72 49.5 Q30.0K 115 67.5 3 and 4 pole Q32 5 3.8 Q52 6 4.2 Q185 12 8.4 Q1.0K 24 17.2 Q3.2K 48 31.1 Q7.5K 72 49.3 Q15.0K 115 67.5 S - sensitive DC voltage adjustment 1 and 2 pole S50 3 2.25 S140 5 3.75 S200 6 4.5 S800 12 9 S3.2K 24 18 S13.0K 48 36 S28.0K 72 54 S50.0K 115 86 3 and 4 pole S30 3 2.25 S80 5 3.75 S110 6 4.5 S450 12 9 S1.8K 24 18 S7.5K 48 36 S16.0K 72 54 S40.0K 115 86 6 pole S20 3 2.25 S56 5 3.75 S80 6 4.5 S320 12 9 S1.2K 24 18 S5.2K 48 36 S13.0K 72 54 S30.0K 115 86 8 pole S12 3 2.25 S35 5 3.75 S52 6 4.5 S200 12 9 S800 24 18 S3.2K 48 36 S7.5K 72 54 S16.0K 115 86 SS - ultra sensitive DC voltage adjustment 1 pole SS220 3 2.25 SS700 5 3.75 SS1.0K 6 4.5 SS4.0K 12 9 SS9.0K 18 13.5 SS15.0K 24 18 SS30.0K 36 27 2 08-2011, Rev. 0811 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Coil resistance Ω±10% Rated coil power mW 52 110 450 1,800 7500 15000 30000 500 350 350 350 310 350 450 32 52 185 1000 3200 7500 15000 800 700 800 600 750 700 900 50 140 200 800 3200 13000 28000 50000 180 180 180 180 180 180 190 270 30 80 110 450 1800 7500 16000 40000 300 350 350 350 350 300 350 350 20 56 80 320 1200 5200 13000 30000 500 500 500 500 500 500 400 500 12 35 52 200 800 3200 7500 16000 750 750 700 750 750 750 700 850 220 700 1000 4000 9000 15000 30000 45 40 40 40 40 40 45 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Coil versions, DC coil (continued) Coil Rated Operate Coil code voltage voltage resistance VDC VDC Ω±10% S - sensitive DC voltage adjustment (continued) 2 pole SS110 3 2.25 110 SS350 5 3.75 350 SS500 6 4.5 500 SS2.0K 12 9 2000 SS4.5K 18 13.5 4500 SS7.5K 24 18 7500 SS15.0K 36 27 15000 SS30.0K 48 36 30000 3 and 4 pole SS52 3 2.25 52 SS175 5 3.75 175 SS250 6 4.5 250 SS1.0K 12 9 1000 SS2.2K 18 13.5 2200 SS3.7K 24 18 3700 SS7.5K 36 27 7500 SS15.0K 48 36 15000 Coil Maximum Operate Coil code coil current current resistance mADC mADC Ω±10% J - sensitive DC current adjustment 2 pole J1.0K 45 8.5 1000 J2.5K 28 5.8 2500 J5.0K 20 4.1 5000 J10.0K 14 3.1 10000 J15.0K 11.5 2.6 15000 J30.0K 8.3 1.7 30000 4 pole J1.0K 45 13 1000 J2.5K 28 8.4 2500 J5.0K 20 6.2 5000 J10.0K 14 4.5 10000 J15.0K 11.5 3.5 15000 J30.0K 8.3 2.5 30000 6 pole J1.0K 45 16 1000 J2.5K 28 10 2500 J5.0K 20 7.2 5000 J10.0K 14 5 10000 J15.0K 11.5 4.2 15000 J30.0K 8.3 2.9 30000 8 pole J1.0K 45 20 1000 J2.5K 28 13 2500 J5.0K 20 9 5000 J10.0K 14 6.4 10000 J15.0K 11.5 5.3 15000 J30.0K 8.3 3.7 30000 J - sensitive DC current adjustment - R10S types only 1 pole J500 1) – 4.5 500 J1.0K 1) – 3.2 1000 J2.5K – 2 2500 J5.0K 2) – 1.4 5000 J10.0K – 1 10000 J16.0K – 0.8 16000 J30.0K 3) – 0.6 30000 Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Rated coil power mW 85 75 75 75 75 80 85 80 175 150 150 150 150 150 175 150 Pick-up coil power mW 75 85 85 100 100 85 175 175 200 200 200 200 250 250 250 250 270 250 250 250 250 250 270 250 10 10 10 10 10 10 11 Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. General Purpose Relays Industrial Relays Potter & Brumfield R10 Series Panel Plug-in Relay (Continued) 1) Suggested for 5VDC operation 2) Suggested for 12VDC operation 3) Suggested for 24VDC operation JJ - ultrasensitive DC current adjustment 1 pole JJ1.0K 45 4.5 JJ2.5K 28 2.9 JJ5.0K 20 2.1 JJ10.0K 14 1.5 JJ15.0K 11.5 1.2 JJ30.0K 8.3 0.85 2 pole JJ1.0K 45 6.5 JJ2.5K 28 4.1 JJ5.0K 20 2.9 JJ10.0K 14 2 JJ15.0K 11.5 1.7 JJ30.0K 8.3 1.2 4 pole JJ1.0K 45 9 JJ2.5K 28 5.8 JJ5.0K 20 4.1 JJ10.0K 14 3 JJ15.0K 11.5 2.4 JJ30.0K 8.3 1.7 1000 2500 5000 10000 15000 30000 20 25 25 25 25 25 1000 2500 5000 10000 15000 30000 45 45 45 40 45 45 1000 2500 5000 10000 15000 30000 85 85 85 90 85 90 Typical Operate and Release Time 25 20 8 6 Release Time (no suppression) 10 1.0 10 (all contact configurations) 15 5 12 4 2 Operate Time 1.33 1.5 2.0 2.5 Multiple of Max. Pull-in Voltage or Current Release Time (Milliseconds) 45 45 45 45 40 35 45 30 (Curves for reference only. If specific values are required, testing is required.) 3.0 R10 Ultra-Sensitive “SS” and “JJ” Typical Ranges of Operation @ 25°C (Curves for reference only. If specific values are required, testing is required.) 10 50 40 Typical Operate and Release Time (all contact configurations) 30 8 6 Release Time (no suppression) 20 10 Operate Time 4 2 Release Time (Milliseconds) 20 20 25 20 20 25 20 Operative Range R10 Relays (DC Only) Typical Ranges of Operations @ 25°C Operate Time (Milliseconds) Pick-up coil power mW Operate Time (Milliseconds) Coil versions, DC coil (continued) Coil Maximum Operate Coil code coil current current resistance mADC mADC Ω±10% J - sensitive DC current adjustment – R10S types only 2 pole J500 1) – 6.3 500 J1.0K – 4.5 1000 J2.5K 2) – 2.9 2500 J5.0K – 2 5000 J10.0K 3) – 1.4 10000 J16.0K – 1.2 16000 J30.0K – 0.8 30000 4 pole J500 – 9 500 J1.0K – 6.5 1000 J2.5K 2) – 4.1 2500 J5.0K 3) – 2.9 5000 J10.0K – 2 10000 J16.0K – 1.4 16000 J30.0K – 1.2 30000 3.0 4.0 1.0 1.5 2.0 Multiple of Max. Pull-in Voltage or Current Typical Coil Inductance 500 Coil versions, AC coil (dual coil diode rectified construction) Coil Rated Operate Coil code voltage voltage resistance VAC VAC Ω±20% Standard AC 2 and 4 pole 6V 6 5 25 12V 12 9 120 24V 24 18 500 48V 48 36 2000 115V 115 86 9000 6 and 8 pole 6V 6 5 15 12V 12 9 90 24V 24 18 350 48V 48 36 1400 115V 115 86 7500 Coil Inductance (Henrys) All figures are given for coil without preenergization, at ambient temperature +23°C. 100 50 10 Armature (open) Armature (closed) 1.0 0.5 0.1 10 50 100 500 1K 5K 10K 100K Coil Resistance (Ohms) All figures are given for coil without preenergization, at ambient temperature +23°C. 08-2011, Rev. 0811 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 3 General Purpose Relays Industrial Relays Potter & Brumfield R10 Series Panel Plug-in Relay (Continued) Insulation Data Other Data (continued) Initial dielectric strength between open contacts between contact and coil between adjacent contacts Initial insulation resistance between insulated elements Terminal type Solder/plug-in terminals, PCB-THT, 8- or 11-PIN octal type plug Weight 23 to 40g Packaging/unit tray/50 pcs., box/350pcs. 500Vrms 1000Vrms 1000Vrms 10GΩ, 500VDC Accessories For details see datasheet Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -55ºC to 75ºC Category of environmental protection IEC 61810 RTI - dust protected and RTIII - wash tight Sockets and Accessories, R10 Relays Product Code Description Many versions of sockets and clips available. NOTE: Relays with contact current <50mA are not recommended for use in sockets. Dimensions .735 MAX. (18.67) 1.187 MAX . (30.15) R10S: 1.50 MAX. (38.1) CASE E ONLY .406 (10.31) 2 POLE .950 MAX. (24.13, 2 POLE 1R10) 4 POLE 1.165 MAX. (29.59, 4 POLE 1R10) 6 POLE 1.375 MAX. (34.93) 8 POLE 1.580 MAX. (40.13) .085 MAX. (2.16) .135 (3.43) .171 (4.43) .354 (8.99) 3-48 THREAD NIB .091 DIA. x .020 HIGH (2.31) (.51) CASE R ONLY Recommend tape tab be removed after immersion cleaning and before relay is put in service. Peel off to permit proper relay ventilation. TYPE E6 ONLY .210 (5.33) } TYPE E1 ONLY .156 (3.96) .375 (9.53) #6-32 THREAD TYPE E6 ONLY .59 REF. (15.0) .437 (11.10) STUD ON NARR OW SIDE ONLY Terminal dimensions Solder terminal dimensions .090 (2.29) Printed circuit terminal dimensions B .040 (1.02) C A D (TO TOP OF CASE) .012 (.30) .080 (2.03) Type 2 Type 7 Type 9 Thickness A .131 .131 .170 .012 B .050 .040 .040 .012 C .064 .013 .000 .012 D 1.251 1.20 1.187 .013 Arrang. Inline Inline Staggered ––– Terminal assignment 28 9 10 12 13 21 11 23 24 11 9 10 22 9 10 20 21 8 19 17 6 18 7 5 14 15 8 14 15 8 7 13 6 7 13 6 7 17 16 18 6 8 7 8 9 5 8 9 5 11 12 5 11 12 5 14 15 5 4 3 2 1 2 POLE 08-2011, Rev. 0811 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company 4 3 2 3 POLE 1 13 20 6 1 14 12 19 10 2 27 25 10 7 3 26 9 6 1 POLE 16 16 10 4 4 16 22 R10 - AC Coil Diagram 15 4 3 2 4 POLE 1 4 3 2 6 POLE Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. 1 4 3 2 DUAL COIL 1 8 POLE Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. General Purpose Relays Industrial Relays Potter & Brumfield R10 Series Panel Plug-in Relay (Continued) PCB layout Suggested panel cutout for relay Bottom view on solder pins Terminal Types E2 & R2 (Omit unnecessary holes) .210 (5.33) .110 (2.79) Terminal Types E9 & R9 (Omit unnecessary holes) .100 (2.54) GRID .740 .530 (18.80) .420 (13.46) (10.67) .320 (8.13) .400 .550 (10.16) (13.97) .450 (11.43) Mounting hole layout for terminal & mounting style 6 .630 (16.00) HOLES .004 DIA. .056 +- .000 .10 (1.42 +- .00 ) + .13 ( ) ( 2.77 – .00 ) 6 POLE 4 2 POLE POLE .500 (12.70) HOLES + .004 .056 - .000 DIA. 1.42 + .10 - .00 .187 ± .0 02 DIA . (4.75 ± .05) 2 HOLES ± .010 + .005 .109 – .000 DIA. TOLERANCE: (± .25) .500 (12.70) .450 (11.43) .150 (3.81) Product code structure .100 (2.54) .281 (7.14) .656 ± .015 (16.66 ± .38) .437 (11.10) X .140 (3.56) .354 (8.99) .147 ± .0 02 DIA . (3.73 ± .05) .281 ± .015 (7.14 ± .38) X = 2 POLE – .343 ± .020 (8.71 ± .51) 4 POLE – .562 ± .020 (14.27 ± .51) 6 POLE – .781 ± .020 (19.84 ± .51) 8 POLE – 1.000 ± .020 (25.40 ± .51) Typical product code R10 -E 1 Y 4 -V700 Type R10 Cradle-style relay with form C contacts R10S Super sensitive cradle-style relay with form C contacts Case style E Non-sealed polycarbonate dust cover (RTI) R Wash-tight (RTIII), tape sealed plastic case 1) T Octal style base on non-sealed polycarbonate dust cover (terminal types 1 & 2 only; 1, 2 & 3 poles only) 1) R10 type only, terminal code 2 or 9 only, no ground or stud Terminal and mounting 1 Solder/Plug-in terminals with #3-48 mounting stud on R10-E; 8-pin octal type on R10-T 2 PCB terminals (std.) 1.62mm (.064in) clearance, 31.75mm (1.25in) seated ht.; 11-pin octal type on R10-T 6 Side mounting plate with #6-32 stud, solder/plug-in terminals (#3-48 stud not included) 7 Narrow 1.02mm (.04in) PCB terminals, .33mm (.013in) clearance, 30.48mm (1.2in) seated ht. 9 Non-shouldered, narrow 1.02mm (.04in) PCB terminals in staggered arrangement 2) 2) Available only on 1 through 6 pole models Contact style and rating 3) W Single contact rated 7.5A max, 300mA min. 4) 5) X Single contact rated 5A max, 300mA min. 5) 6) M Bifurcated contact rated 5A max, 300 mA min. 5) 6) Y Single contact rated 2A typ, 3A max, 100mA min. Z Bifurcated low level contacts rated 100mA typ, 2A max, 1mA min. P Bifurcated crossbar dry circuit contacts rated 1mA typ, 3A max, dry circuit min. L Bifurcated crossbar dry circuit contacts rated 500 microA typ, 250 mA max, dry circuit min. 3) Ratings are at 28VDCV or 115VAC. Total load must not exceed 30A per relay. 4) Use ungrounded frame for AC load of ≥5A. Max ratings are 7.5A at 115VAC and 4A at 28VDC for coil codes S & J 5) Only available on R10 type, only available with coil adjustment code V, Q, S and J. 6) Use ungrounded frame for AC load of ≥5A. Max ratings are 5A at 115VAC and 3A at 28VDC for coil codes S & J Number of poles 1 1 pole 2 2 pole 3 3 pole 4 6 8 4 pole (not available on R10-T) 6 pole (not available on R10-T) 7) 8 pole (not available on R10-T) 8) 7) Not available with contact code W 8) Only available with case style E, not available with contact code W Coil voltage Coil code: please refer to coil versions table AC voltage Specify coil code consisting of nominal coil voltage followed by W (example: 24V) DC voltage Specify coil code consisting of coil adjustment code letter followed by coil resistance (example: V700) 08-2011, Rev. 0811 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 5 General Purpose Relays Industrial Relays Potter & Brumfield R10 Series Panel Plug-in Relay (Continued) Product Code Arrangement R10-E1P2-115V R10-E1P2-V700 R10-E1P4-115V R10-E1P4-V700 R10-E1W2-V185 R10-E1W2-V700 R10-E1W4-V185 R10-E1W4-V700 R10-E1X2-24V R10-E1X2-115V R10-E1X2-S800 R10-E1X2-V185 R10-E1X2-V700 R10-E1X4-115V R10-E1X4-V185 R10-E1X4-V700 R10-E1X4-V2.5K R10-E1X6-115V R10-E1X6-V90 R10-E1X6-V430 R10-E1Y2-J1.0K R10-E1Y2-J2.5K R10-E1Y2-V185 R10-E1Y2-V700 R10-E1Y2-V2.5K R10-E1Y2-V15.0K R10-E1Y4-J10.0K R10-E1Y4-V52 R10-E1Y4-V2.5K R10-E1Y4-V700 R10-E1Y6-V430 R10-E1Y6-V1.5K R10-E1Z2-V185 R10-E1Z2-V700 R10-E1Z4-V185 R10-E1Z4-V700 R10-E1Z4-V2.5K R10-E1Z6-V430 R10-E1Z6-V1.5K R10-T1P2-115V R10S-E1Y1-J1.0K R10S-E1Y2-J5.0K R10-E2P4-V185 R10-E2P4-V700 R10-E2W2-V185 R10-E2X2-V185 R10-E2X2-V700 R10-E2X4-V185 R10-E2X4-V700 R10-E2Y2-V185 R10-E2Y2-V700 R10-E2Y4-V185 R10-E2Y4-V700 R10S-E2Y1-J1.0K 6 Material 2 Form C, 2 CO Au overlay Ag Contact Style/Rating Nom. Coil V Bif crossbar / dry circuit 115 VAC 24 VDC 115 VAC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC 24 VAC 115 VAC 12 VDC 4 Form C, 4 CO 2 Form C, 2 CO AgCdO Single contact / 7.5A 4 Form C, 4 CO 2 Form C, 2 CO Single contact / 5A 4 Form C, 4 CO 6 Form C, 6 CO 2 Form C, 2 CO Ag Single contact / 2A typical Terminals & Mounting Part Number Solder/plug-in w/ #3-48 mounting stud 7-1393765-0 6-1393765-9 7-1393765-6 7-1393765-5 8-1393765-9 9-1393765-1 9-1393765-3 9-1393765-5 1-1393766-1 1-1393766-0 1393766-3 1393766-5 1393766-9 1-1393766-8 1-1393766-4 1-1393766-7 1-1393766-5 2-1393766-5 2-1393766-4 2-1393766-2 3-1393766-3 3-1393766-4 4-1393766-0 4-1393766-4 4-1393766-1 3-1393766-9 4-1393766-9 5-1393766-6 5-1393766-5 5-1393766-7 6-1393766-1 6-1393766-0 7-1393766-2 7-1393766-4 7-1393766-9 8-1393766-1 8-1393766-0 8-1393766-6 8-1393766-5 2-1393769-8 7-1393769-0 7-1393769-5 1393767-3 1393767-4 1393767-7 1-1393767-1 1-1393767-5 1-1393767-7 1-1393767-8 2-1393767-6 2-1393767-9 3-1393767-5 3-1393767-6 8-1393769-1 24 VDC 115 VAC 12 VDC 24 VDC 48 VDC 115 VAC 12 VDC 24 VAC Not applicable 12 VDC 24 VDC 48 VDC 115 VDC Not applicable 4 Form C, 4 CO 48 VDC 24 VDC 6 Form C, 6 CO 2 Form C, 2 CO Bifurcated / 100mA typical 4 Form C, 4 CO 6 Form C, 6 CO 2 Form C, 2 CO Au overlay Ag Bif crossbar / dry circuit 1 Form C, 1 CO Ag Single contact / 2A typical 2 Form C, 2 CO 4 Form C, 4 CO Au overlay Ag Bif crossbar / dry circuit 2 Form C, 2 CO AgCdO Single contact / 5A 4 Form C, 4 CO 2 Form C, 2 CO Ag Single contact / 2A typical 4 Form C, 4 CO 1 Form C, 1 CO 08-2011, Rev. 0811 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. 48 VDC 12 VDC 24 VDC 12 VDC 24 VDC 48 VDC 24 VDC 48 VDC 115 VAC Not applicable 12 VDC 24 VDC 12 VDC PCB, .064" clearance, 1.25" seated ht. 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC Not applicable Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.