TI SLK2701IPZP

SLLS518 − DECEMBER 2001
D Fully Integrated SONET/SDH Transceiver to
D
D
D
D
D
D
D
D
Support Clock/Data Recovery and
Multiplexer/Demultiplexer Functions
Supports OC-48, OC-24, OC-12, Gigabit
Ethernet, and OC-3 Data Rate With Autorate
Detection
Supports Transmit Only, Receiver Only,
Transceiver and Repeater Functions in a
Single Chip Through Configuration Pins
Supports SONET/SDH Frame Detection
On-Chip PRBS Generation and Verification
Supports 4-Bit LVDS (OIF99.102) Electrical
Interface
Parity Checking and Generation for the
LVDS Interface
Single 2.5-V Power Supply
Interfaces to Back Plane, Copper Cables, or
Optical Modules
D Hot Plug Protection
D Low Jitter PECL-Compatible Differential
D
D
D
D
D
D
D
D
D
D
Serial Interface With Programmable
De-Emphasis for the Serial Output
On-Chip Termination for LVDS and
PECL-Compatible Interface
Receiver Differential Input Thresholds
150 mV Minimum
Supports SONET Loop Timing
Low Power <900 mW at OC-48 Data Rate
ESD Protection >2 kV
622-MHz Reference Clock
Maintains Clock Output in Absence of Data
Local and Remote Loopback
100-Pin PZP Package With PowerPad
Design
Supports FEC Data Rate of 2.7 Gbps
description
The SLK2701 device is a single chip, multirate transceiver that derives high-speed timing signals for SONET/
SDH-based equipment. The device performs clock and data recovery, serial-to-parallel/parallel-to-serial
conversion, and a frame detection function conforming to the SONET/SDH standards.
The device can be configured to operate under OC-48, OC-24, OC-12, or OC-3 data rate through the rate
selection pins or the autorate detection function. An external reference clock operating at 622.08 MHz is
required for the recovery loop, and it also provides a stable clock source in the absence of serial data transitions.
The SLK2701 device accepts 4-bit LVDS parallel data/clock and generates a NRZ SONET/SDH-compliant
signal at the OC-3, OC-12, OC-24, or OC-48 data rate. It also recovers the data and clock from the serial SONET
stream and demultiplexes it into 4-bit LVDS parallel data for full duplex operation. TXDATA0 and RXDATA0 are
the first bits that are transmitted and received in time, respectively. The serial interface is a low jitter,
PECL-compatible differential interface.
The SLK2701 device supports an FEC data rate up to 2.7 Gbps when configured to operate at the OC-48 data
rate and provided with an external reference clock that is properly scaled.
The SLK2701 device provides a comprehensive suite of built-in tests for self-test purposes including local and
remote loopback and pseudorandom bit stream (PRBS) (27-1) generation and verification.
The device comes in a 100-pin VQFP package that requires a single 2.5-V supply with 3.3-V tolerant inputs on
the control pins. The SLK2701 device is very power efficient, dissipating less than 900 mW at 2.488 Gbps, the
OC-48 data rate. It is characterised for operation from −40°C to 85°C.
AVAILABLE OPTIONS
PACKAGE
TA
PowerPAD QUAD
(PZP)
−40°C to 85°C
SLK2701PZP
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PowerPAD is a trademark of Texas Instruments.
Copyright  2001, Texas Instruments Incorporated
!"# $ %&'# "$ (&)*%"# +"#',
+&%#$ %! # $('%%"#$ (' #-' #'!$ '."$ $#&!'#$
$#"+"+ /""#0, +&%# (%'$$1 +'$ # '%'$$"*0 %*&+'
#'$#1 "** (""!'#'$,
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SLLS518 − DECEMBER 2001
block diagram
PRBSEN
PRBS
Generator
4
SPILL
TXDATA0..TXDATA3
TXCLKP
FIFO
4-Bit
Register
2:1
MUX
4
4
4:1
MUX
STXDOP
MUX
STXDON
4
TXCLKN
TXPARP
Parity
Checker
TXPARN
PAR_VALID
RLOOP
TXCLKRCP
TXCLKRCN
REFCLKP
Rate
Select
MUX
Transmit Clock
Synthesizer
REFCLKN
LCKREFN
LOOPTIME
RSEL(0−1)
To All The Logic
Recovered
Clock
RESET
Receive Clock
Recovery
LOL
LLOOP
PRBS
Verification
PRBSPASS
Parity
Generator
4-Bit
Register
RXDAT0..RXDATA3
4
Frame
Sync
4
4
1:4
MUX
Q
D
SRXDIP
SRXDIN
LOS
SIGDET
RXPARP
RXPARN
RXCLKP
DIV
RXCLKN
FRAMEN
FSYNCP
FSYNCN
2
2:1
MUX
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
100
99
98
97
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
GNDLVDS
TXPARP
TXPARN
VDDLVDS
GNDLVDS
REFCLKN
REFCLKP
GNDLVDS
VDDLVDS
VDDLVDS
VDDLVDS
GNDLVDS
TXDATA0P
TXDATA0N
TXDATA1P
TXDATA1N
TXDATA2P
TXDATA2N
TXDATA3P
TXDATA3N
TXCLKN
TXCLKP
VDDLVDS
GNDLVDS
GNDLVDS
PZP PACKAGE
(TOP VIEW)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
VDDLVDS
FSYNCN
FSYNCP
VDDLVDS
TXCLKSRCN
TXCLKSRCP
GNDLVDS
RXCLKN
RXCLKP
RXDATA0P
RXDATA0N
RXDATA1P
RXDATA1N
VDDLVDS
GNDLVDS
RXDATA2P
RXDATA2N
RXDATA3P
RXDATA3N
RXPARP
RXPARN
RLOOP
LLOOP
RSVD
LOOPTIME
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
LOL
LOS
RX_MONITOR
RESET
SPILL
VDD
ENABLE
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
75
74
73
72
71
70
69
68
67
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
GND
FRAME_EN
GND
VDD
GND
GND
VDD
GND
AUTO_DETECT
VDD
RATEOUT1
RATEOUT0
RSEL1
RSEL0
GND
PRBSEN
PRBSPASS
TESTEN
GND
PAR_VALID
VDD
PRE1
PRE2
GND
VDDA
STXDON
STXDOP
GNDA
VDDPLL
GNDPLL
GNDA
SRXDIP
SRXDIN
VDDA
CONFIG0
CONFIG1
GND
SIGDET
PS
VDD
GND
LCKREFN
VDD
3
SLLS518 − DECEMBER 2001
Terminal Functions
clock pins
TERMINAL
NAME
NO.
TYPE
DESCRIPTION
REFCLKP
REFCLKN
94
95
LVDS/PECL
compatible input
Differential reference input clock. There is an on-chip 100-Ω termination resistor differentially
placed between REFCLKP and REFCLKN. The dc bias is also provided on-chip for the
ac-coupled case.
RXCLKP
RXCLKN
67
68
LVDS output
Receive data clock. The data on RXDATA(0:3) is on the falling edges of RXCLKP. The interface
of RXDATA(0:3) and RXCLKP is source synchronous (refer to Figure 7).
TXCLKP
TXCLKN
79
80
LVDS input
Transmit data clock. The data on TXDATA(0:3) is latched on the rising edge of TXCLKP.
TXCLKSRCP
TXCLKSRCN
70
71
LVDS output
Transmit clock source. A clock source generated from the SLK2701 device to the downstream
device (i.e., framer) that could be used by the downstream device to transmit data back to the
SLK2701 device. This clock is frequency-locked to the local reference clock.
serial side data pins
TERMINAL
NAME
TYPE
NO.
DESCRIPTION
SRXDIP
SRXDIN
14
15
PECL compatible
input
Receive differential pairs; high-speed serial inputs
STXDOP
STXDON
9
8
PECL compatible
output
Transmit differential pairs; high-speed serial outputs
parallel side data pins
TERMINAL
NAME
FSYNCP
FSYNCN
RXDATA[0:3]
P/N
RXPARP
RXPARN
TXDATA[0:3]
P/N
TXPARP
TXPARN
4
NO.
TYPE
DESCRIPTION
73
74
LVDS output
Frame sync pulse. This signal indicates the frame boundaries of the incoming data stream. If the
frame-detect circuit is enabled, FSYNC pulses for four RXCLKP and RXCLKN clock cycles,
when it detects the framing patterns.
66−63
60−57
LVDS output
Receive data pins. Parallel data on this bus is valid on the falling edge of RXCLKP (refer to
Figure 7). RXDATA0 is the first bit received in time.
56
55
LVDS output
Receive data parity output
88−81
LVDS input
Transmit data pins. Parallel data on this bus is clocked on the rising edge of TXCLKP.
TXDATA0 is the first bit transmitted in time.
99
98
LVDS input
Transmit data parity input
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
Terminal Functions (Continued)
control/status pins
TERMINAL
NAME
NO.
TYPE
DESCRIPTION
AUTO_DETECT
34
TTL input (with pulldown)
Data rate autodetect enable. Enable the autodetection function for different data rates.
CONFIG0
CONFIG1
17
18
TTL input (with pulldown)
Configuration pins. Put the device under one of the four operation modes: TX only, RX
only, transceiver, or repeater.
ENABLE
44
TTL input (with pullup)
Standby enable. When this pin is held low, the device is disabled for IDDQ testing.
When high, the device operates normally.
FRAME_EN
27
TTL input (with pullup)
Frame sync enable. When this pin is asserted high, the frame synchronization circuit
for byte alignment is turned on.
LCKREFN
24
TTL input (with pullup)
Lock to reference. When this pin is low, RXCLKP/N output is forced to lock to REFCLK.
When high, RXCLKP/N is the divided down clock extracted from the receive serial
data.
LLOOP
53
TTL input (with pulldown)
Local loopback enable. When this pin is high, the serial output is internally looped back
to its serial input.
LOL
45
TTL output
Loss of lock. When the clock recovery loop has locked to the input data stream and the
phase differs by less than 100 ppm from REFCLK, then LOL is high. When the phase of
the input data stream differs by more than 100 ppm from REFCLK, then LOL is low. If
the difference is too large (> 500 ppm), the LOL output is not valid.
LOOPTIME
51
TTL input (with pulldown)
Loop timing mode. When this pin is high, the PLL for the clock synthesizer is bypassed.
The recovered clock timing is used to send the transmit data.
LOS
46
TTL output
Loss of signal. When no transitions appear on the input data stream for more than
2.3 µs, a loss of signal occurs and LOS goes high. The device also transmits all zeroes
downstream using REFCLK as its clock source. When a valid SONET signal is
received, the LOS signal goes low.
PAR_VALID
2
TTL output
Parity checker output. The internal parity checker on the parallel side of the transmitter
checks for even parity. If there is a parity error, the pin is pulsed low for two clock cycles.
PRBSEN
41
TTL input (with pulldown)
PRBS testing enable. When this pin is asserted high, the device is put into the PRBS
testing mode.
PRBSPASS
42
TTL output
PRBS test result. This pin reports the status of the PRBS test results (high = pass).
When PRBSEN is disabled, the PRBSPASS pin is set low. When PRBSEN is enabled
and a valid PRBS is received, then the PRBSPASS pin is set high.
PRE1
PRE2
4
5
TTL input (with pulldown)
Programmable preemphasis control. Combinations of these two bits can be used to
optimize serial data transmission.
PS
21
TTL input (with pulldown)
Polarity select. This pin, used with the SIGDET pin, sets the polarity of SIGSET. When
high, SIGDET is an active low signal. When low, SIGDET is an active high signal.
RATEOUT0
RATEOUT1
37
36
TTL output
Autorate detection outputs. When AUTO_DETECT is high, the autodetection circuit
generates these two bits to indicate the data rates for the downstream device.
RESET
48
TTL input (with pulldown)
TXFIFO and LOL reset pin. Low is reset and high is normal operation.
RLOOP
54
TTL input (with pulldown)
Remote loopback enable. When this pin is high, the serial input is internally looped
back to its serial output with the timing extracted from the serial data.
RSEL0
RSEL1
39
38
TTL input (with pulldown)
Data rate configuration pins. Put the device under one of the four data rate operations:
OC-48, OC-24, OC-12, or OC-3.
RX_MONITOR
47
TTL input (with pulldown)
RX parallel data monitor in repeater mode. This pin is only used when the device is put
under repeater mode. When high, the RX demultiplexer circuit is enabled and the
parallel data is presented. When low, the demultiplexer is shut down to save power.
SIGDET
20
TTL input (with pulldown)
Signal detect. This pin is generally connected to the output of an optical receiver. This
signal may be active high or active low depending on the optical receiver. The SIGDET
input is XORed with the PS pin to select the active state. When SIGDET is in the
inactive state, data is processed normally. When activated, indicating a loss of signal
event, the transmitter transmits all zeroes and force the LOS signal to go high.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
SLLS518 − DECEMBER 2001
Terminal Functions(Continued)
control/status pins (continued)
TERMINAL
NAME
TYPE
NO.
DESCRIPTION
SPILL
49
TTL output
TX FIFO collision output
TESTEN
43
TTL input (with pulldown)
Production test mode enable. This pin must be left unconnected or tied low.
voltage supply and reserved pins
TERMINAL
NAME
GND
NO.
TYPE
DESCRIPTION
1, 6, 19, 23, 26,
28, 30, 31, 33,
40
Ground
Digital logic ground
10, 13
Ground
Analog ground
61, 69, 76, 77,
89, 93, 96, 100
Ground
LVDS ground
GNDPLL
12
Supply
PLL ground
RSVD
52
Reserved
This pin needs to be tied to ground or left floating for normal operation.
3, 22, 25, 29,
32, 35, 50
Supply
Digital logic supply voltage (2.5 V)
7, 16
Supply
Analog voltage supply (2.5 V)
62, 72, 75, 78,
90, 91, 92, 97
Supply
LVDS supply voltage (2.5 V)
11
Supply
PLL voltage supply (2.5 V)
GNDA
GNDLVDS
VDD
VDDA
VDDLVDS
VDDPLL
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
detailed description
The SLK2701 device is designed to support the OC-48/24/12/3 data rates. It also supports a higher data rate
that may be required for FEC support, up to 2.7 Gbps. The operating data speed can be configured through the
RSEL0 and RSEL1 pins as indicated in Table 1 for normal SONET rates. For FEC support, the clock and data
rates need to be scaled up as required. The highest data and clock rates supported are 675 Mbps and 675 MHz,
respectively.
Table 1. Data Rate Select
SERIAL DATA RATE
RSEL0
RSEL1
PARALLEL LVDS DATA RATE
TXCLK/RXCLK
OC-48: 2.488 Gbps
0
0
622.08 Mbps
622.08 MHz
OC-24: 1.244 Gbps
1
0
311.04 Mbps
311.04 MHz
OC-12: 622 Mbps
0
1
155.52 Mbps
155.52 MHz
OC-3: 155.52 Mbps
1
1
38.88 Mbps
38.88 MHz
The user can also enable the autorate detection circuitry through the AUTO_DETECT pin. The device
automatically detects the OC-N of the data line rate and generates two bits of output to indicate the data rate
to other devices in the system. When using AUTO_DETECT, RSEL0 and RSEL1 need to be set to 00 or be
unconnected.
Table 2. Data Rate Reporting Under Autorate Detection Mode
SERIAL DATA RATE
RATEOUT0
RATEOUT1
PARALLEL LVDS DATA RATE
TXCLK/RXCLK
OC-48: 2.488 Gbps
0
0
622.08 Mbps
622.08 MHz
OC-24: 1.244 Gbps
1
0
311.04 Mbps
311.04 MHz
OC-12: 622 Mbps
0
1
155.52 Mbps
155.52 MHz
OC-3: 155.52 Mbps
1
1
38.88 Mbps
38.88 MHz
The SLK2701 device has four operational modes controlled by two configuration pins. Table 3 lists these
operational modes. When the device is put in a certain mode, unused circuit blocks are powered down to
conserve system power.
While the transceiver mode, transmit only mode, and receive only mode are straightforward, the repeater mode
of operation is shown in Figure 5. The receive serial data is recovered by the extracted clock, and it is then sent
back out on the transmit serial outputs. The data eye is open both vertically and horizontally in this process. In
the repeater mode, the user can select to turn on the RX demultiplexer function through RX_MONITOR pin and
allow the parallel data to be presented. This feature enables the repeater device not only to repeat but also to
listen in.
Table 3. Operational Modes
MODE
CONFIG0
CONFIG1
1
0
0
Full duplex transceiver mode
DESCRIPTION
2
0
1
Transmit only mode
3
1
0
Receive only mode
4
1
1
Repeater mode
high-speed electrical interface
The high-speed serial I/O uses a PECL-compatible interface. The line could be directly coupled or ac-coupled.
Refer to Figures 10 and 11 for configuration details. As shown in the figures, an on-chip 100-Ω termination
resistor is placed differentially at the receive end.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
SLLS518 − DECEMBER 2001
detailed description (continued)
The PECL output also provides preemphasis for compensating ac loss when driving a cable or PCB backplane
over long distance. The level of the preemphasis is programmable via the PRE1 and PRE2 pins. Users can use
software to control the strength of the preemphasis to optimize the device for a specific system requirement.
Table 4. Programmable De-emphasis
DE-EMPHASIS LEVEL
(Vodp/Vodd†−1)
PRE1
PRE2
0
0
De-emphasis disabled
1
0
10%
0
1
20%
1
1
30%
† Vodp: Differential voltage swing when there is a transition in the data stream.
Vodd: Differential voltage swing when there is no transition in the data stream.
V(ODp)
V(ODd)
V(ODd)
0
Bit
Time
Bit
Time
V(ODp)
Figure 1. Output Differential Voltage Under De-emphasis
LVDS parallel data interface
The parallel data interface consists of a 4-bit parallel LVDS data and clock. The device conforms to the
OIF99.102 specification when operating at the OC-48 rate. When operating at lower serial rates, the clock and
data frequency are scaled down accordingly, as indicated in Table 1. The parallel data TXDATA[0:3] is latched
on the rising edge of TXCLK and then is sent to a data FIFO to resolve any phase difference between TXCLK
and REFCLK. If there is a FIFO overflow condition, the SPILL pin is set high. The FIFO resets itself to realign
between two clocks. The internal PLL for the clock synthesizer is locked to the REFCLK, and it is used as the
timing to serialize the parallel data (except for the loop timing mode where the recovered clock is used). On the
receive side, RXDATA[0:3] is updated on the rising edge of RXCLK. Figures 7 and 8 show the timing diagram
for the parallel interface.
The SLK2701 device also has a built-in parity checker and generator for error detection of the LVDS interface.
On the transmit side, it accepts the parity bit, TXPARP/N, and performs the parity checking function for even
parity. If an error is detected, it pulses the PAR_VALID pin low for two clock cycles. On the receive side, the parity
bit, RXPARP/N, is generated for the downstream device for parity error checking.
Differential termination 100-Ω resistors are included on-chip between TXDATAP/N and TXCLKP/N.
reference clock
The device accepts a 622.08-MHz clock. The REFCLK input is compatible with the LVDS level and also the
3.3-V LVPECL level using ac-coupling. A 100-Ω differential termination resistor is included on-chip, as well as
a dc-biasing circuit (3 kΩ to VDD and 4.5 kΩ to GND) for the ac-coupled case. A high quality REFCLK must be
used on systems required to meet SONET/SDH standards. For non-SONET/SDH-compliant systems, loose
tolerances may be used.
8
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
detailed description (continued)
clock and data recovery
The CDR unit of the SLK2701 device recovers the clock and data from the incoming data streams.
In the event of receive data loss, the PLL automatically locks to the local REFCLK to maintain frequency stability.
If the frequency of the data differs by more that 100 ppm with respect to the REFCLK frequency, the LOL pin
is asserted as a warning. Actual loss of lock occurs if the data frequency differs by more than 170 ppm.
minimum transition density
The loop filter transfer function is optimized to enable the CDR to track ppm difference in the clocking and
tolerate the minimum transition density that can be received in a SONET data signal (±20 ppm). The transfer
function yields a typical capture time of 3500-bit times for random incoming NRZ data after the device is powered
up and achieves frequency locking.
The device tolerates up to 72 consecutive digits (CID) without sustaining an error.
jitter transfer
20 Log (Jitter In/Jitter Out) − dB
The jitter transfer is less than the mask shown in Figure 2 (GR-253 Figure 5-27). Jitter transfer function is defined
as the ratio of jitter on the output signal to the jitter applied on the input signal versus frequency. The input
sinusoidal jitter amplitude is applied up to the mask level in the jitter tolerance requirement (see Figure 3).
P
Slope = −20 dB / Decade
fc
(kHz)
P
(dB)
130
0.1
12
500
0.1
24
Not Specified
48
2000
OC-N/STS-N
LEVEL
3
0.1
fc
Frequency − kHz
Figure 2. Jitter Transfer
jitter tolerance
Input jitter tolerance is defined as the peak-to-peak amplitude of sinusoidal jitter applied on the input signal that
causes the equivalent 1-dB optical/electrical power penalty. This refers to the ability of the device to withstand
input jitter without causing a recovered data error. The device has a jitter tolerance that exceeds the mask shown
in Figure 3 (GR-253 Figure 5-28). This jitter tolerance is specified using a pseudorandom data pattern of 231 –1.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
SLLS518 − DECEMBER 2001
Input Jitter Amplitude − UIpp
jitter tolerance (continued)
A3
Slope = −20 dB / Decade
A2
Slope = −20 dB / Decade
A1
f0
f1
f2
f3
f4
Frequency − Hz
OC-N/STS-N
LEVEL
f0
(Hz)
F1
(Hz)
F2
(Hz)
F3
(kHz)
3
10
30
300
12
10
30
300
24
48
F4
(kHz)
A1
(Ulpp)
A2
(Ulpp)
A3
(Ulpp)
6.5
65
0.15
1.5
15
25
250
0.15
1.5
15
0.15
1.5
15
Not specified
10
600
6000
100
1000
Figure 3. Input Jitter Tolerance
jitter generation
The jitter of a serial clock and serial data outputs must not exceed 0.01 UIrms/0.1 UIp-p when a serial data with
no jitter is presented to the inputs. The measurement bandwidth for intrinsic jitter is 12 kHz to 20 MHz.
loop timing mode
When LOOPTIME is high, the clock synthesizer used to serialize the transmit data is bypassed and the timing
is provided by the recovered clock. However, REFCLK is still needed for the recovery loop operation.
loss-of-lock indicator
The SLK2701 device has a lock detection circuit to monitor the integrity of the data input. When the clock
recovery loop is locked to the input serial data stream, the LOL signal goes high. If the recovered clock frequency
deviates from the reference clock frequency by more than 100 ppm, LOL goes low. If the data stream clock rate
deviates by more than 170 ppm, loss of lock occurs. If the data streams clock rate deviates more than 500 ppm
from the local reference clock, the LOL output status might be unstable. Upon power up, the LOL goes low until
the PLL is close to phase lock with the local reference clock.
loss of signal
The loss-of-signal (LOS) alarm is set high when no transitions appear in the input data path for more than 2.3 µs.
The LOS signal becomes active when the above condition occurs. If the serial inputs of the device are
ac-coupled to its source, the ac-coupling capacitor needs to be big enough to maintain a signal level above the
threshold of the receiver for the 2.3-µs no transition period. Once activated, the LOS alarm pin is latched high
until the receiver detects an A1A2 pattern. The recovered clock (RXCLK) is automatically locked to the local
reference when LOS occurs. The parallel data (RXDATAx) may still be processed even when LOS is activated.
10
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
detailed description (continued)
signal detect
The SLK2701 device has an input SIGDET pin to force the device into the loss-of-signal state. This pin is
generally connected to the signal detect output of the optical receiver. Depending on the optics manufacturer,
this signal can be either active high or active low. To accommodate the differences, a polarity select (PS) is used.
For an active low, SIGDET input sets the PS pin high. For an active high, SIGDET input sets the PS pin low.
When the PS signal pin and SIGDET are of opposite polarities, the loss-of-signal state is generated and the
device transmits all zeroes downstream.
multiplexer operation
The 4-bit parallel LVDS data is clocked into an input buffer by a clock derived from the synthesized clock. The
data is then clocked into a 4:1 multiplexer. The D0 bit is the most significant bit and is shifted out first in the serial
output stream.
demultiplexer operation
The serial 2.5-Gbps data is clocked into a 1:4 demultiplexer by the recovered clock. The D0 bit is the first bit
that is received in time from the input serial stream. The 4-bit parallel data is then sent to the LVDS driver along
with the divided down recovered clock.
frame synchronization
The SLK2701 device has a SONET/SDH-compatible frame detection circuit that can be enabled or disabled
by the user. Frame detection is enabled when the FRAME_EN pin is high. When enabled, it detects the A1, A2
framing pattern, which is used to locate and align the byte and frame boundaries of the incoming data stream.
When FRAME_EN is low, the frame detection circuitry is disabled and the byte boundary is frozen to the location
found when detection was previously enabled.
The frame detect circuit searches the incoming data for three consecutive A1 bytes followed immediately by
one A2 byte. The data alignment circuit then aligns the parallel output data to the byte and frame boundaries
of the incoming data stream. During the framing process the parallel data bus will not contain valid and aligned
data. Upon detecting the third A1, A2 framing patterns that are separated by 125 µs from each other, the FSYNC
signal goes high for four RXCLK cycles, indicating frame synchronization has been achieved.
The probability that random data in a SONET/SDH data stream will mimic the framing pattern in the data payload
is extremely low. However, there is a state machine built in to prevent false reframing if a framing pattern does
show up in the data payload.
testability
The SLK2701 device has a comprehensive suite of built-in self-tests. The loopback function provides for
at-speed testing of the transmit/receive portions of the circuitry. The ENABLE pin allows for all circuitry to be
disabled so that an IDDQ test can be performed. The PRBS function allows for a built-in self-test (BIST).
IDDQ function
When held low, the ENABLE pin disables all quiescent power in both the analog and digital circuitry. This allows
for IDDQ testing on all power supplies and can also be used to conserve power when the link is inactive.
local loopback
The LLOOP signal pin controls the local loopback. When LLOOP is high, the loopback mode is activated and
the parallel transmit data is selected and presented on the parallel receive data output pins. The parallel transmit
data is also multiplexed and presented on the high-speed serial transmit pins. Local loopback can only be
enabled when the device is under transceiver mode.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
SLLS518 − DECEMBER 2001
detailed description (continued)
SRXDIP
D
SRXDIN
RXDATA (3−0)
1:4 Serial to
Parallel
Recovered Clock
RXCLK
LLOOP
TXDATA (3−0)
STXDOP
D
STXDON
4:1 Parallel to
Serial
TXCLK
2.488 GHz
PLL
Figure 4. Local Loopback Data Path
remote loopback
The RLOOP signal pin controls the remote loopback. When RLOOP is high, the serial receive data is selected
and presented on the serial transmit data output pins. The serial received data is also demultiplexed and
presented on the parallel receive data pins. The remote loop can be enabled only when the device is under
transceiver mode. When the device is put under the repeater mode with RX_MONITOR high, it performs the
same function as remote loopback.
SRXDIP
SRXDIN
D
RXDATA (3−0)
1:4 Serial to
Parallel
RXCLK
Recovered Clock
STXDOP
D
STXDON
4:1 Parallel to
Serial
LLOOP
2.488 GHz
PLL
Figure 5. Remote Loopback Data Path/Repeater Mode Operation
PRBS
The SLK2701 device has two built-in pseudorandom bit stream (PRBS) functions. The PRBS generator is used
to transmit a PRBS signal. The PRBS verifier is used to check and verify a received PRBS signal.
When the PRBSEN pin is high, the PRBS generator and verifier are both enabled. A PRBS is generated and
fed into the parallel transmitter input bus. Data from the normal input source is ignored in PRBS mode. The
PBRS pattern is then fed through the transmitter circuitry as if it was normal data and sent out by the transmitter.
The output can be sent to a bit error rate tester (BERT) or to the receiver of another SLK2701 device. If an error
occurs in the PRBS pattern, the PRBSPASS pin is set low for two RXCLKP/N cycles.
12
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
detailed description (continued)
power-on reset
Upon application of minimum valid power, the SLK2701 device generates a power-on reset. During the
power-on reset the PRXDATA[0:3] signal pins go to 3-state. RXCLKP and RXCLKN are held low. The length
of the power-on reset cycle is dependent upon the REFCLKP and REFCLKN frequency but is less than 1 ms
in duration.
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage, VDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 to 3 V
Voltage range: TTL input terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 to 4 V
LVDS terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 to 3 V
Any other terminal except above . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 to VDD + 0.3 V
Package power dissipation, PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Storage temperature, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Electrostatic discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HBM: 2 kv
Characterized free-air operating temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE
PACKAGE
PZP‡
PZP¶
TA ≤ 2 5°C
POWER RATING
DERATING FACTOR§
ABOVE TA = 25°C
3.4 W
33.78 mW/°C
1.3 W
2.27 W
22.78 mW/°C
0.911 W
TA = 85°C
POWER RATING
‡ 2 oz trace and copper pad with solder.
§ This is the inverse of the traditional junction-to-ambient thermal resistance (RθJA).
¶ 2 oz trace and copper pad without solder.
recommended operating conditions
PARAMETER
TEST CONDITIONS
Supply voltage, VDD
Power dissipation, PD
Frequency = 2.488 Gb/sec, PRBS pattern
Shutdown current
Enable = 0, VDDA, VDD pins, VDD = max
Operating free-air temperature, TA
MIN
NOM
MAX
2.3
2.5
2.7
V
700
900
mW
µA
20
−40
UNIT
85
°C
start up sequence
To ensure proper start up, follow one of the following steps when powering up the SLK2701 device.
1. Keep ENABLE (pin 44) low until power supplies and reference clock have become stable.
2. Drive ENABLE (pin 44) low for at least 30 ns after power supplies and reference clock have become stable.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
13
SLLS518 − DECEMBER 2001
electrical characteristics over recommended operating conditions (unless otherwise noted)
TTL
PARAMETER
VIH
VIL
High-level input voltage
IIH
IIL
Input high current
VOH
VOL
High-level output voltage
CI
Input capacitance
TEST CONDITIONS
MIN
TYP
2
3.6
Low-level input voltage
VDD = MAX,
VDD = MAX,
Input low current
VIN = 2 V
VIN = 4 V
IOH = −1 mA
IOH = 1 mA
Low-level output voltage
MAX
V
0.80
V
40
µA
µA
−40
2.10
UNIT
2.3
0.25
V
0.5
V
4
pF
LVDS input signals
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
1575
mV
VI
VID(th)
Input voltage
825
Input differential threshold voltage
100
CI
Input capacitance
RI
Input differential impedance
On-chip termination
tsu
th
Input setup time requirement
See Figure 8
300
ps
Input hold time requirement
See Figure 8
300
ps
T(duty)
Input clock duty cycle
80
mV
100
40%
3
pF
120
Ω
60%
LVDS output signals
PARAMETER
VOD
VOS
Output differential voltage
∆VOD
∆VOS
Change VOD between 1 and 0
Output common mode voltage
t(cq_max)
tr/tf
RL = 100 ±1%
MIN
TYP
MAX
300
800
1070
1375
25
Change VOS between 1 and 0
I(SP), I(SN),
I(SPN)
Ioff
t(cq_min)
TEST CONDITIONS
UNIT
mV
25
Output short circuit current
Outputs shorted to ground or shorted together
Power-off current
VDD = 0 V
24
mA
10
µA
100
Clock-output time
See Figure 7
Output transition time
20% to 80%
100
Output clock duty cycle
ps
100
300
45%
55%
4
7
Bit
times
MAX
UNIT
20
ppm
Data output to FRAME_SYNC delay
ps
timing requirements over recommended operating conditions (unless otherwise noted)
reference clock (REFCLK)
PARAMETER
TEST CONDITIONS
Frequency tolerance†
MIN
TYP
−20
Duty cycle
40%
Jitter
50%
12 kHz to 20 MHz
Frequency range absolute value
60%
3
ps rms
MHz
† The ±20-ppm tolerance is required to meet SONET/SDH requirements. For non-SONET/SDH-compliant systems, looser tolerances may apply.
14
622.08
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
PLL performance specifications
PARAMETER
TEST CONDITIONS
PLL startup lock time
VDD, VDDC = 2.3 V, after REFCLK is stable
Acquisition lock time
Valid SONET signal or PRBS OC-48
MIN
TYP
MAX
1
UNIT
ms
Bit
Times
2031
serial transmitter/receiver characteristics
PARAMETER
TEST CONDITIONS
Vodd = |STXDOP−STXDON|, transmit
differential output voltage under
preemphasis
V(CMT)
Transmit common mode voltage range
MIN
NOM
MAX
UNIT
mV
PRE1 = 0,
PRE2 = 0, Rt = 50,
See Table 4 and Figure 1
650
850
1000
PRE1 = 1,
PRE2 = 0
550
750
900
PRE1 = 0,
PRE2 = 1
540
700
860
PRE1 = 1,
PRE2 = 1
500
650
800
1100
1250
1400
Rt = 50 Ω
Receiver Input voltage requirement,
Vid = |SRXDIP−SRXDIN|
150
V(CMR)
Il
Receiver common mode voltage range
1100
Receiver input leakage
−550
Rl
CI
Receiver differential impedance
mV
mV
mV
1250
2250
mV
550
µA
120
Ω
1
pF
td(TX_Latency)
50
td(RX_Latency)
50
Bit
Times
80
100
Receiver input capacitance
serial differential switching characteristics over recommended operating conditions (unless
otherwise noted)
PARAMETER
tt
tj
TEST CONDITIONS
Output jitter
RL = 50 Ω,
Jitter-free data,
12 kHz to 20 MHz, RLOOP = 1
Jitter tolerance
RLOOP = 1
See Figure 3
Jitter transfer
RLOOP = 1
See Figure 2
Differential signal rise time (20% to 80%)
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
MIN
TYP
MAX
80
100
140
UNIT
ps
0.05
0.1
UI(pp)
15
SLLS518 − DECEMBER 2001
TYPICAL CHARACTERISTICS
49.9 Ω
VOD
49.9 Ω
VOS
CL = 5 pF Max
100%
80%
VOD(H)
0V
VOD(L)
20%
0%
tr
tf
Figure 6. Test Load and Voltage Definitions for LVDS Outputs
RXCLKP
t(cq_min)
t(cq_max)
RXDATA
P/N
Figure 7. LVDS Output Waveform
TXCLKP
tsu
th
TXDATA
P/N
Figure 8. LVDS Input Waveform
16
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
APPLICATION INFORMATION
50 Ω
CL
5 pF
50 Ω
CL
5 pF
Figure 9. Transmitter Test Setup
VDD
TXP
50
5 kΩ
RXP
5 kΩ
VDD
100 Ω
TXN
50
GND
+
_
5 kΩ
RXN
5 kΩ
GND
Transmitter
Media
Receiver
Figure 10. High-Speed I/O Directly-Coupled Mode
VDD
TXP
5 kΩ
RXP
50
5 kΩ
100 Ω
TXN
VDD
GND
5 kΩ
RXN
50
+
_
5 kΩ
GND
Transmitter
Media
Receiver
Figure 11. High-Speed I/O AC-Coupled Mode
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
17
SLLS518 − DECEMBER 2001
APPLICATION INFORMATION
designing with the PowerPad package
The SLK2701 device is housed in high-performance, thermally enhanced, 100-pin PZP PowerPAD packages.
Use of a PowerPAD package does not require any special considerations except to note that the PowerPAD,
which is an exposed die pad on the bottom of the device, is a metallic thermal and electrical conductor. Correct
device operation requires that the PowerPAD be soldered to the thermal land. Do not run any etches or signal
vias under the device, but have only a grounded thermal land, as explained below. Although the actual size of
the exposed die pad may vary, the minimum size required for the keepout area for the 100-pin PZP PowerPAD
package is 12 mm × 12 mm.
A thermal land, which is an area of solder-tinned-copper, is required underneath the PowerPAD package. The
thermal land varies in size depending on the PowerPAD package being used, the PCB construction, and the
amount of heat that needs to be removed. In addition, the thermal land may or may not contain numerous
thermal vias, depending on PCB construction.
Other requirements for thermal lands and thermal vias are detailed in the TI application note PowerPAD
Thermally Enhanced Package Application Report, TI literature number SLMA002, available via the TI Web
pages beginning at URL http://www.ti.com.
Figure 12. Example of a Thermal Land
For the SLK2701 device, this thermal land must be grounded to the low-impedance ground plane of the device.
This improves not only thermal performance but also the electrical grounding of the device. It is also
recommended that the device ground terminal landing pads be connected directly to the grounded thermal land.
The land size must be as large as possible without shorting device signal terminals. The thermal land may be
soldered to the exposed PowerPAD using standard reflow soldering techniques.
While the thermal land may be electrically floated and configured to remove heat to an external heat sink, it is
recommended that the thermal land be connected to the low-impedance ground plane of the device. More
information may be obtained from the TI application note PHY Layout, TI literature number SLLA020.
18
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SLLS518 − DECEMBER 2001
MECHANICAL DATA
PZP (S-PQFP-G100)
PowerPAD PLASTIC QUAD FLATPACK
0,27
0,17
0,50
75
0,08 M
51
50
76
Thermal Pad
(see Note D)
26
100
0,13 NOM
1
25
12,00 TYP
Gage Plane
14,20
SQ
13,80
16,20
SQ
15,80
0,25
0,15
0,05
1,05
0,95
0°−ā 7°
0,75
0,45
Seating Plane
0,08
1,20 MAX
4146929/A 04/99
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion.
The package thermal performance may be enhanced by bonding the thermal pad to an external thermal plane.
This pad is electrically and thermally connected to the backside of the die and possibly selected leads.
E. Falls within JEDEC MS-026
For the latest package information, go to http://www.ti.com/sc/docs/package/pkg_info.htm
PowerPAD is a trademark of Texas Instruments.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
19
PACKAGE OPTION ADDENDUM
www.ti.com
4-Feb-2005
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
SLK2701IPZP
ACTIVE
HTQFP
PZP
Pins Package Eco Plan (2)
Qty
100
90
None
Lead/Ball Finish
CU NIPDAU
MSL Peak Temp (3)
Level-3-220C-168 HR
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - May not be currently available - please check http://www.ti.com/productcontent for the latest availability information and additional
product content details.
None: Not yet available Lead (Pb-Free).
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Green (RoHS & no Sb/Br): TI defines "Green" to mean "Pb-Free" and in addition, uses package materials that do not contain halogens,
including bromine (Br) or antimony (Sb) above 0.1% of total product weight.
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDECindustry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address:
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2005, Texas Instruments Incorporated