STMICROELECTRONICS M41T11M

M41T11
512 bit (64b x8) Serial Access TIMEKEEPER® SRAM
■
2.0V to 5.5V SUPPLY VOLTAGE
■
COUNTERS for SECONDS, MINUTES,
HOURS, DAY, DATE, MONTH, YEARS and
CENTURY
■
YEAR 2000 COMPLIANT
■
SOFTWARE CLOCK CALIBRATION
■
AUTOMATIC SWITCH-OVER and DESELECT
CIRCUITRY
■
I2C BUS COMPATIBLE
■
56 BYTES of GENERAL PURPOSE RAM
■
ULTRA-LOW BATTERY SUPPLY CURRENT
of 1µA
■
LOW OPERATING CURRENT of 300µA
■
OPERATING TEMPERATURE of –40 to 85°C
■
AUTOMATIC LEAP YEAR COMPENSATION
■
SPECIAL SOFTWARE PROGRAMMABLE
OUTPUT
■
PACKAGING INCLUDES a 28-LEAD SOIC and
SNAPHAT® TOP (to be Ordered Separately)
Table 1. Signal Names
OSCI
Oscillator Input
OCSO
Oscillator Output
FT/OUT
Frequency Test / Output Driver
(Open drain)
SDA
Serial Data Address Input / Output
SCL
Serial Clock
VBAT
Battery Supply Voltage
VCC
Supply Voltage
VSS
Ground
SNAPHAT (SH)
Battery & Crystal
8
1
28
SOH28 (MH)
Figure 1. Logic Diagram
VCC
VBAT
OSCO
OSCI
SCL
May 2000
1
SO8 (M)
150mil Width
M41T11
SDA
FT/OUT
VSS
AI01000
1/19
M41T11
Figure 2B. SOH28 Connections
Figure 2A. SO8 Connections
M41T11
OSCI
OSCO
VBAT
VSS
1
2
3
4
8
7
6
5
VCC
FT/OUT
SCL
SDA
AI01001
DESCRIPTION
The M41T11 TIMEKEEPER® RAM is a low power
512 bit static CMOS RAM organized as 64 words
by 8 bits. A built-in 32.768 kHz oscillator (external
crystal controlled) and the first 8 bytes of the RAM
are used for the clock/calendar function and are
configured in binary coded decimal (BCD) format.
Addresses and data are transferred serially via a
two-line bi-directional bus. The built-in address
register is incremented automatically after each
write or read data byte.
The M41T11 clock has a built-in power sense circuit which detects power failures and automatically switches to the battery supply during power
failures. The energy needed to sustain the RAM
and clock operations can be supplied from a small
lithium coin cell.
Typical data retention time is in excess of 5 years
with a 50mA/h 3V lithium cell. The M41T11 is supplied in 8 lead Plastic Small Outline package or 28
lead SNAPHAT package.
The 28 pin 330mil SOIC provides sockets with
gold plated contacts at both ends for direct connection to a separate SNAPHAT housing contain-
2/19
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
VSS
1
28
27
2
26
3
25
4
24
5
23
6
22
7
M41T11
21
8
20
9
19
10
18
11
17
12
16
13
15
14
VCC
NC
FT/OUT
NC
NC
NC
NC
NC
SCL
NC
NC
NC
SDA
NC
AI03606
ing the battery and crystal. The unique design
allows the SNAPHAT battery package to be
mounted on top of the SOIC package after the
completion of the surface mount process. Insertion of the SNAPHAT housing after reflow prevents potential battery and crystal damage due to
the high temperatures required for device surfacemounting. The SNAPHAT housing is keyed to prevent reverse insertion. The SOIC and battery/crystal packages are shipped separately in plastic antistatic tubes or in Tape & Reel form.
For the 28 lead SOIC, the battery/crystal package
(i.e. SNAPHAT) part number is "M4TxxBR12SHx".
Caution: Do not place the SNAPHAT battery/crystal package "M4Txx-BR12SHx" in conductive
foam since this will drain the lithium button-cell
battery.
M41T11
Table 2. Absolute Maximum Ratings (1)
Symbol
TA
TSTG
TSLD (2)
Parameter
Ambient Operating Temperature
Storage Temperature (VCC Off, Oscillator Off)
Lead Solder Temperature for 10 seconds
Value
Unit
–40 to 85
°C
SNAPHAT
–40 to 85
SOIC
–55 to 125
°C
260
°C
VIO
Input or Output Voltages
–0.3 to 7
V
VCC
Supply Voltage
–0.3 to 7
V
IO
Output Current
20
mA
PD
Power Dissipation
0.25
W
Note: 1. Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or any other conditions above those indicated in the operational section
of this specification is not implied. Exposure to the absolute maximum rating conditions for extended periods of time may affect
reliability.
2. Soldering temperature not to exceed 260°C for 10 seconds (total thermal budget not to exceed 150°C for longer than 30 seconds).
CAUTION: Negative undershoots below –0.3V are not allowed on any pin while in the Battery Back-up mode.
CAUTION: Do NOT wave solder SOIC to avoid damaging SNAPHAT sockets.
OPERATION
The M41T11 clock operates as a slave device on
the serial bus. Access is obtained by implementing
a start condition followed by the correct slave address (D0h). The 64 bytes contained in the device
can then be accessed sequentially in the following
order:
1.
Seconds Register
2.
Minutes Register
3.
Century/Hours Register
4.
Day Register
5.
Date Register
6.
Month Register
7.
Years Register
8.
Control Register
9 to 64. RAM
The M41T11 clock continually monitors VCC for an
out of tolerance condition. Should VCC fall below
VSO, the device terminates an access in progress
and resets the device address counter. Inputs to
the device will not be recognized at this time to
prevent erroneous data from being written to the
device from an out of tolerance system. When V CC
falls below VSO, the device automatically switches
over to the battery and powers down into an ultra
low current mode of operation to conserve battery
life. Upon power-up, the device switches from battery to VCC at VSO and recognizes inputs.
3/19
M41T11
Figure 3. Block Diagram
1 Hz
SECONDS
OSCI
OSCILLATOR
32.768 kHz
MINUTES
DIVIDER
CENTURY/HOURS
OSCO
DAY
FT/OUT
DATE
MONTH
VOLTAGE
SENSE
and
SWITCH
CIRCUITRY
VCC
VSS
VBAT
SCL
YEAR
CONTROL
LOGIC
CONTROL
RAM
(56 x 8)
SERIAL
BUS
INTERFACE
ADDRESS
REGISTER
SDA
AI02566
Table 3. Register Map
Data
Function/Range
BCD Format
Address
D7
D6
D5
D4
D3
D2
D1
D0
0
ST
10 Seconds
Seconds
Seconds
00-59
1
X
10 Minutes
Minutes
Minutes
00-59
2
CEB (1)
CB
Hours
Century/Hour
0-1/00-23
3
X
X
Day
01-07
4
X
X
Date
Date
01-31
5
X
X
Month
Month
01-12
Years
Year
00-99
6
7
10 Hours
X
10 Date
X
10 Years
OUT
FT
X
S
10 M.
X
Day
Calibration
Control
Note: 1. When CEB is set to ’1’, CB will toggle from ’0’ to ’1’ or from ’1’ to ’0’ every 100 years (dependent upon the initial value set).
When CEB is set to ’0’, CB will not toggle.
Keys:
4/19
S = SIGN Bit;
FT = FREQUENCY TEST Bit;
ST = STOP Bit;
OUT = Output level;
X = Don’t care;
CEB = Century Enable Bit;
CB = Century Bit.
M41T11
Table 4. AC Measurement Conditions
Input Rise and Fall Times
≤ 5ns
Input Pulse Voltages
0.2VCC to 0.8VCC
Input and Output Timing Ref.
Voltages
0.3VCC to 0.7VCC
Figure 4. AC Testing Load Circuit
0.8VCC
0.7VCC
Note that Output Hi-Z is defined as the point where data is no longer
driven.
0.3VCC
0.2VCC
2-WIRE BUS CHARACTERISTICS
This bus is intended for communication between
different ICs. It consists of two lines: one bi-directional for data signals (SDA) and one for clock signals (SCL). Both the SDA and the SCL lines must
be connected to a positive supply voltage via a
pull-up resistor.
The following protocol has been defined:
– Data transfer may be initiated only when the bus
is not busy.
– During data transfer, the data line must remain
stable whenever the clock line is High.
– Changes in the data line while the clock line is
High will be interpreted as control signals.
Accordingly, the following bus conditions have
been defined:
Bus not busy. Both data and clock lines remain
High.
Start data transfer. A change in the state of the
data line, from High to Low, while the clock is High,
defines the START condition.
Stop data transfer. A change in the state of the
data line, from Low to High, while the clock is High,
defines the STOP condition.
AI02568
Data valid. The state of the data line represents
valid data when after a start condition, the data line
is stable for the duration of the High period of the
clock signal. The data on the line may be changed
during the Low period of the clock signal. There is
one clock pulse per bit of data.
Each data transfer is initiated with a start condition
and terminated with a stop condition. The number
of data bytes transferred between the start and
stop conditions is not limited. The information is
transmitted byte-wide and each receiver acknowledges with a ninth bit.
By definition, a device that gives out a message is
called "transmitter", the receiving device that gets
the message is called "receiver". The device that
controls the message is called "master". The devices that are controlled by the master are called
"slaves".
Table 5. Capacitance (1, 2)
(TA = 25 °C, f = MHz)
Symbol
CIN
COUT (3)
tLP
Parameter
Max
Unit
Input Capacitance (SCL)
7
pF
Output Capacitance (SDA, FT/OUT)
10
pF
1000
ns
Low-pass filter input time constant (SDA and SCL)
Min
250
Note: 1. Effective capacitance measured with power supply at 5V.
2. Sampled, not 100% tested.
3. Outputs deselected.
5/19
M41T11
Table 6. DC Characteristics
(TA = –40 to 85 °C; VCC = 2.0V to 5.5V)
Symbol
Parameter
Test Condition
Min
Typ
Max
Unit
0V ≤ VIN ≤ VCC
±1
µA
0V ≤ VOUT ≤ VCC
±1
µA
Switch Frequency = 100kHz
300
µA
SCL, SDA = VCC – 0.3V
70
µA
ILI
Input Leakage Current
ILO
Output Leakage Current
ICC1
Supply Current
ICC2
Supply Current (Standby)
VIL
Input Low Voltage
–0.3
0.3VCC
V
VIH
Input High Voltage
0.7VCC
VCC + 0.8
V
VOL
Output Low Voltage
0.4
V
3
3.5
V
0.8
1
µA
VBAT (1)
Battery Supply Voltage
IBAT
Battery Supply Current
IOL = 3mA
2
TA = 25°C, VCC = 0V,
Oscillator ON, VBAT = 3V
Note: 1. STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent) as the battery supply.
Table 7. Power Down/Up Trip Points DC Characteristics (1)
(TA = –40 to 85 °C)
Symbol
VSO (2)
Parameter
Battery Back-up Switchover Voltage
Min
Typ
Max
Unit
VBAT –0.70
VBAT –0.50
VBAT –0.30
V
Min
Typ
Max
Unit
Note: 1. All voltages referenced to VSS.
2. Switch-over and deselect point.
Table 8. Crystal Electrical Characteristics
(Externally Supplied if using the SO8 package)
Symbol
Parameter
fO
Resonant Frequency
RS
Series Resistance
CL
Load Capacitance
32.768
kHz
35
12.5
kΩ
pF
Note: Load capacitors are integrated within the M41T11. Circuit board layout considerations for the 32.768 kHz crystal of minimum trace
lengths and isolation from RF generating signals should be taken into account.
STMicroelectronics recommends the KDS DT-38 Tuning Fork Type quartz crystal for industrial temperature operations.
KDS can be contacted at 913-491-6825 or http://www.kdsj.co.jp for further information on this crystal type.
All SNAPHAT battery/crystal tops meet these specifications.
6/19
M41T11
Table 9. Power Down/Up AC Characteristics (1)
(TA = –40 to 85 °C)
Symbol
tPD
tREC
Parameter
Min
Max
Unit
SCL and SDA at VIH before Power Down
0
ns
SCL and SDA at VIH after Power Up
10
µs
Note: 1. VCC fall time should not exceed 5mV/µs.
Figure 5. Power Down/Up Mode AC Waveforms
VCC
VSO
tPD
SDA
SCL
tREC
DON'T CARE
AI00596
Acknowledge. Each byte of eight bits is followed
by one acknowledge bit. This acknowledge bit is a
low level put on the bus by the receiver, whereas
the master generates an extra acknowledge related clock pulse.
A slave receiver which is addressed is obliged to
generate an acknowledge after the reception of
each byte. Also, a master receiver must generate
an acknowledge after the reception of each byte
that has been clocked out of the slave transmitter.
The device that acknowledges has to pull down
the SDA line during the acknowledge clock pulse
in such a way that the SDA line is a stable Low during the High period of the acknowledge related
clock pulse. Of course, setup and hold times must
be taken into account. A master receiver must signal an end-of-data to the slave transmitter by not
generating an acknowledge on the last byte that
has been clocked out of the slave. In this case, the
transmitter must leave the data line High to enable
the master to generate the STOP condition.
7/19
M41T11
Table 10. AC Characteristics
(TA = –40 to 85 °C; VCC = 2.0V to 5.5V)
Symbol
Parameter
Min
Max
Unit
0
100
kHz
fSCL
SCL Clock Frequency
tLOW
Clock Low Period
4.7
µs
tHIGH
Clock High Period
4
µs
tR
SDA and SCL Rise Time
1
µs
tF
SDA and SCL Fall Time
300
ns
tHD:STA
START Condition Hold Time
(after this period the first clock pulse is generated)
tSU:STA
4
µs
START Condition Setup Time
(only relevant for a repeated start condition)
4.7
µs
tSU:DAT
Data Setup Time
250
ns
tHD:DAT (1)
Data Hold Time
0
µs
STOP Condition Setup Time
4.7
µs
Time the bus must be free before a new transmission can start
4.7
µs
tSU:STO
tBUF
Note: 1. Transmitter must internally provide a hold time to bridge the undefined region (300ns max.) of the falling edge of SCL.
WRITE MODE
In this mode the master transmitter transmits to
the M41T11 slave receiver. Bus protocol is shown
in Figure 10. Following the START condition and
slave address, a logic ’0’ (R/W = 0) is placed on the
bus and indicates to the addressed device that
word address An will follow and is to be written to
the on-chip address pointer. The data word to be
written to the memory is strobed in next and the internal address pointer is incremented to the next
memory location within the RAM on the reception
of an acknowledge clock. The M41T11 slave receiver will send an acknowledge clock to the master transmitter after it has received the slave
address and again after it has received the word
address and each data byte (see Figure 9).
READ MODE
In this mode, the master reads the M41T11 slave
after setting the slave address (see Figure 11).
Following the write mode control bit (R/W = 0) and
the acknowledge bit, the word address A n is writ-
8/19
ten to the on-chip address pointer. Next the
START condition and slave address are repeated,
followed by the READ mode control bit (R/W = 1).
At this point, the master transmitter becomes the
master receiver. The data byte which was addressed will be transmitted and the master receiver will send an acknowledge bit to the slave
transmitter. The address pointer is only incremented on reception of an acknowledge bit. The
M41T11 slave transmitter will now place the data
byte at address An + 1 on the bus. The master receiver reads and acknowledges the new byte and
the address pointer is incremented to A n + 2.
This cycle of reading consecutive addresses will
continue until the master receiver sends a STOP
condition to the slave transmitter.
An alternate READ mode may also be implemented, whereby the master reads the M41T11 slave
without first writing to the (volatile) address pointer. The first address that is read is the last one
stored in the pointer, see Figure 12.
M41T11
Figure 6. Serial Bus Data Transfer Sequence
DATA LINE
STABLE
DATA VALID
CLOCK
DATA
START
CONDITION
CHANGE OF
DATA ALLOWED
STOP
CONDITION
AI00587
Figure 7. Acknowledgment Sequence
CLOCK PULSE FOR
ACKNOWLEDGEMENT
START
SCLK FROM
MASTER
DATA OUTPUT
BY TRANSMITTER
1
MSB
2
8
9
LSB
DATA OUTPUT
BY RECEIVER
AI00601
CLOCK OPERATION
The eight byte clock register (see Table 3) is used
to both set the clock and to read the date and time
from the clock, in a binary coded decimal format.
Seconds, Minutes, and Hours are contained within
the first three registers. Bits D6 and D7 of clock
register 2 (Hours Register) contain the CENTURY
ENABLE Bit (CEB) and the CENTURY Bit (CB).
Setting CEB to a ’1’ will cause CB to toggle, either
from ’0’ to ’1’ or from ’1’ to ’0’ at the turn of the century (depending upon its initial state). If CEB is set
to a ’0’, CB will not toggle. Bits D0 through D2 of
register 3 contain the Day (day of week). Registers
4, 5 and 6 contain the Date (day of month), Month
and Years. The final register is the Control Register (this is described in the Clock Calibration section). Bit D7 of register 0 contains the STOP Bit
(ST). Setting this bit to a ’1’ will cause the oscillator
to stop. If the device is expected to spend a significant amount of time on the shelf, the oscillator
may be stopped to reduce current drain. When reset to a ’0’ the oscillator restarts within one second.
The seven Clock Registers may be read one byte
at a time, or in a sequential block. The Control
Register (Address location 7) may be accessed independently. Provision has been made to assure
that a clock update does not occur while any of the
seven clock addresses are being read. If a clock
address is being read, an update of the clock registers will be delayed by 250ms to allow the read
to be completed before the update occurs. This
will prevent a transition of data during the read.
Note: This 250ms delay affects only the clock register update and does not alter the actual clock
time.
9/19
M41T11
Figure 8. Bus Timing Requirements Sequence
SDA
tBUF
tHD:STA
tHD:STA
tR
tF
SCL
tHIGH
P
S
tLOW
tSU:DAT
tHD:DAT
tSU:STA
SR
tSU:STO
P
AI00589
Note: P = STOP and S = START
Figure 9. Slave Address Location
R/W
SLAVE ADDRESS
1
A
LSB
MSB
START
1
0
1
0
0
0
AI00602
CLOCK CALIBRATION
The M41T11 is driven by a quartz controlled oscillator with a nominal frequency of 32,768Hz. The
devices are tested not to exceed 35ppm (parts per
million) oscillator frequency error at 25°C, which
equates to about ±1.53 minutes per month. With
the calibration bits properly set, the accuracy of
each M41T11 improves to better than +1/–2 ppm
at 25°C.
The oscillation rate of any crystal changes with
temperature (see Figure 14). Most clock chips
compensate for crystal frequency and temperature shift error with cumbersome trim capacitors.
The M41T11 design, however, employs periodic
10/19
counter correction. The calibration circuit adds or
subtracts counts from the oscillator divider circuit
at the divide by 256 stage, as shown in Figure 13.
The number of times pulses are blanked (subtracted, negative calibration) or split (added, positive
calibration) depends upon the value loaded into
the five bit Calibration byte found in the Control
Register. Adding counts speeds the clock up, subtracting counts slows the clock down.
The Calibration byte occupies the five lower order
bits (D4-D0) in the Control register (Addr 7). This
byte can be set to represent any value between 0
and 31 in binary form. Bit D5 is a Sign bit; '1' indicates positive calibration, '0' indicates negative
calibration. Calibration occurs within a 64minute
cycle. The first 62 minutes in the cycle may, once
per minute, have one second either shortened by
128 or lengthened by 256 oscillator cycles. If a binary '1' is loaded into the register, only the first 2
minutes in the 64 minute cycle will be modified; if
a binary 6 is loaded, the first 12 will be affected,
and so on.
Therefore, each calibration step has the effect of
adding 512 or subtracting 256 oscillator cycles for
every 125,829,120 actual oscillator cycles, that is
+4.068 or –2.034 ppm of adjustment per calibration step in the calibration register. Assuming that
the oscillator is in fact running at exactly 32,768Hz,
each of the 31 increments in the Calibration byte
would represent +10.7 or –5.35 seconds per
month which corresponds to a total range of +5.5
or –2.75 minutes per month.
M41T11
STOP
R/W
DATA n+X
SLAVE
ADDRESS
P
ACK
DATA n+1
ACK
BUS ACTIVITY:
DATA n
ACK
WORD
ADDRESS (n)
S
ACK
SDA LINE
ACK
BUS ACTIVITY:
MASTER
START
Figure 10. Write Mode Sequence
AI00591
SLAVE
ADDRESS
DATA n+1
ACK
DATA n
ACK
S
ACK
BUS ACTIVITY:
R/W
START
R/W
WORD
ADDRESS (n)
S
ACK
SDA LINE
ACK
BUS ACTIVITY:
MASTER
START
Figure 11. Read Mode Sequence
STOP
SLAVE
ADDRESS
P
NO ACK
DATA n+X
AI00899
STOP
R/W
SLAVE
ADDRESS
DATA n+X
P
NO ACK
BUS ACTIVITY:
DATA n+1
ACK
DATA n
ACK
S
ACK
SDA LINE
ACK
BUS ACTIVITY:
MASTER
START
Figure 12. Alternate Read Mode Sequence
AI00895
11/19
M41T11
Figure 13. Clock Calibration
NORMAL
POSITIVE
CALIBRATION
NEGATIVE
CALIBRATION
AI00594B
Two methods are available for ascertaining how
much calibration a given M41T11 may require.
The first involves simply setting the clock, letting it
run for a month and comparing it to a known accurate reference (like WWV broadcasts). While that
may seem crude, it allows the designer to give the
end user the ability to calibrate his clock as his environment may require, even after the final product
is packaged in a non-user serviceable enclosure.
All the designer has to do is provide a simple utility
that accessed the Calibration byte.
The second approach is better suited to a manufacturing environment, and involves the use of
some test equipment. When the Frequency Test
(FT) bit, the seventh-most significant bit in the
Control Register, is set to a '1', and the oscillator is
running at 32,768Hz, the FT/OUT pin of the device
will toggle at 512Hz. Any deviation from 512Hz indicates the degree and direction of oscillator frequency shift at the test temperature.
12/19
For example, a reading of 512.01024Hz would indicate a +20ppm oscillator frequency error, requiring a –10(XX001010) to be loaded into the
Calibration Byte for correction. Note that setting or
changing the Calibration Byte does not affect the
Frequency test output frequency.
OUTPUT DRIVER PIN
When the FT bit is not set, the FT/OUT pin becomes an output driver that reflects the contents of
D7 of the control register. In other words, when D6
of location 7 is a zero and D7 of location 7 is a zero
and then the FT/OUT pin will be driven low.
Note: The FT/OUT pin is open drain which requires an external pull-up resistor.
POWER-ON DEFAULTS
Upon initial application of power to the device, the
FT bit will be set to a '0' and the OUT bit will be set
to a '1'. All other Register bits will initially power-on
in a random state.
M41T11
Figure 14. Crystal Accuracy Across Temperature
Frequency (ppm)
20
0
–20
–40
–60
–80
–100
∆F = -0.038 ppm (T - T )2 ± 10%
0
F
C2
–120
T0 = 25 °C
–140
–160
–40
–30
–20
–10
0
10
20
30
40
50
60
70
80
Temperature °C
AI00999
13/19
M41T11
Table 11. Ordering Information Scheme
Example:
M41T11
M
6
TR
Device Type
M41T
Package
M = SO8 150mil Width
MH = SOH28
Temperature Range
6 = –40 to 85 °C
Shipping Method for SO
blank = Tubes
TR = Tape & Reel
Note: The SOIC package (SOH28) requires the battery package (SNAPHAT) which is ordered separately under the part number
"M4Txx-BR12SHx" in plastic tube or "M4Txx-BR12SHxTR" in Tape & Reel form.
Caution: Do not place the SNAPHAT battery package "M4Txx-BR12SHx" in conductive foam since this will drain the lithium button-cell
battery.
For a list of available options or for further information on any aspect of this device, please contact the
STMicroelectronics Sales Office nearest to you.
Table 12. Revision History
Date
Revision Details
March 1999
First Issue
12/23/99
SOH28 package added
05/22/00
RS value change (Table 8)
14/19
M41T11
Table 13. SO8 - 8 pin Plastic Small Outline, 150 mils body width, Package Mechanical Data
mm
inches
Symb
Typ
Min
Max
A
1.35
A1
Min
Max
1.75
0.053
0.069
0.10
0.25
0.004
0.010
B
0.33
0.51
0.013
0.020
C
0.19
0.25
0.007
0.010
D
4.80
5.00
0.189
0.197
E
3.80
4.00
0.150
0.157
–
–
–
–
H
5.80
6.20
0.228
0.244
h
0.25
0.50
0.010
0.020
L
0.40
0.90
0.016
0.035
α
0°
8°
0°
8°
N
8
e
1.27
Typ
0.050
8
CP
0.10
0.004
Figure 15. SO8 - 8 pin Plastic Small Outline, 150 mils body width, Package Outline
h x 45˚
A
C
B
CP
e
D
N
E
H
1
A1
α
L
SO-a
Drawing is not to scale.
15/19
M41T11
Table 14. SOH28 - 28 lead Plastic Small Outline, 4-socket battery SNAPHAT,
Package Mechanical Data
mm
inches
Symb
Typ
Min
Max
A
Typ
Min
3.05
Max
0.120
A1
0.05
0.36
0.002
0.014
A2
2.34
2.69
0.092
0.106
B
0.36
0.51
0.014
0.020
C
0.15
0.32
0.006
0.012
D
17.71
18.49
0.697
0.728
E
8.23
8.89
0.324
0.350
–
–
–
–
eB
3.20
3.61
0.126
0.142
H
11.51
12.70
0.453
0.500
L
0.41
1.27
0.016
0.050
α
0°
8°
0°
8°
N
28
e
1.27
0.050
28
CP
0.10
0.004
Figure 16. SOH28 - 28 lead Plastic Small Outline, 4-socket battery SNAPHAT, Package Outline
A2
A
C
B
eB
e
CP
D
N
E
H
A1
1
SOH-A
Drawing is not to scale.
16/19
α
L
M41T11
Table 15. M4T28-BR12SH - TIMEKEEPER 4-pin SNAPHAT Housing for 48 mAh Battery & Crystal,
Package Mechanical Data
mm
inches
Symb
Typ
Min
A
Max
Typ
Min
Max
9.78
0.385
A1
6.73
7.24
0.265
0.285
A2
6.48
6.99
0.255
0.275
A3
0.38
0.015
B
0.46
0.56
0.018
0.022
D
21.21
21.84
0.835
0.860
E
14.22
14.99
0.560
0.590
eB
3.20
3.61
0.126
0.142
L
2.03
2.29
0.080
0.090
Figure 17. M4T28-BR12SH - TIMEKEEPER 4-pin SNAPHAT Housing for 48 mAh Battery & Crystal,
Package Outline
A1
eA
A2
A
A3
B
L
eB
D
E
SHTK-A
Drawing is not to scale.
17/19
M41T11
Table 16. M4T32-BR12SH - TIMEKEEPER 4-pin SNAPHAT Housing for 120 mAh Battery & Crystal,
Package Mechanical Data
mm
inches
Symb
Typ
Min
A
Max
Typ
Min
Max
10.54
0.415
A1
8.00
8.51
0.315
0.335
A2
7.24
8.00
0.285
0.315
A3
0.38
0.015
B
0.46
0.56
0.018
0.022
D
21.21
21.84
0.835
0.860
E
17.27
18.03
0.680
0.710
eB
3.20
3.61
0.126
0.142
L
2.03
2.29
0.080
0.090
Figure 18. M4T32-BR12SH - TIMEKEEPER 4-pin SNAPHAT Housing for 120 mAh Battery & Crystal,
Package Outline
A1
eA
A2
A
A3
B
L
eB
D
E
SHTK-B
Drawing is not to scale.
18/19
M41T11
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject
to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not
authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is registered trademark of STMicroelectronics
 2000 STMicroelectronics - All Rights Reserved
All other names are the property of their respective owners.
STMicroelectronics GROUP OF COMPANIES
Australia - Brazil - China - Finland - France - Germany - Hong Kong - India - Italy - Japan - Malaysia - Malta - Morocco Singapore - Spain - Sweden - Switzerland - United Kingdom - U.S.A.
http://www.st.com
19/19