CRYSTEKCRYSTAL D121515T-1W

D_T-1W Series
1W, FIXED INPUT, ISOLATED & UNREGULATED
TWIN OUTPUT ULTRAMINIATURE SMD PACKAGE
DC-DC CONVERTER
RoHS
SELECTION GUIDE
FEATURES
● Efficiency up to 80%
● Twin Independent Output
● Small Footprint
● SMD Package Styles
● Industry Standard Pinout
● No Heatsink Required
● 1kVDC Isolation
● High Power Density
● Temperature Range: -40°C ~ +85°C
● No External Component Required
● Internal SMD construction
● RoHS Compliance
Input
Part
Number
Output
Voltage (VDC)
Efficiency
(%,Typ.)
Current (mA)
Voltage
(VDC)
Max.
Min.
D050505T-1W
5/5
100/100
10/10
70
D050909T-1W *
9/9
56/56
6/6
75
Nominal
5
Range
4.5-5.5
D051212T-1W
12/12
42/42
4/4
79
D051515T-1W *
15/15
33/33
3/3
80
D120505T-1W *
5/5
100/100
10/10
72
D120909T-1W *
9/9
56/56
6/6
75
D121212T-1W
12/12
42/42
4/4
78
D121515T-1W
15/15
33/33
3/3
80
12
10.8-13.2
*Designing.
Note: The D_T-W2/W5 series also are available in our company.
APPLICATIONS
The D_T-1W series are specially designed for
applications where a group of polar power
supplies are isolated from the input power
supply in a distributed power supply system on
a circuit board. These products apply to:
1) Where the voltage of the input power
supply is fixed (voltage variation ≤±10%);
2) Where isolation is necessary between input
and output (isolation voltage ≤1000VDC);
3) Where the regulation of the output voltage
and the output ripple and noise are not
COMMON SPECIFICATIONS
Item
Test condition
Min.
Operating temperature
-40
Storage temperature
-55
Temp. rise at full load
Lead temperature
Such as: purely digital circuits, ordinary low
frequency analog circuits and IGBT power
device driven circuits, etc.
Max.
Unit
95
%
85
125
15
1.5mm from case for 10 seconds
°C
25
300
Short circuit protection*
1
Cooling
demanding.
Typ.
Storage humidity
s
Free air convection
package material
Epoxy Resin (UL94-V0)
MTBF
3500
Weight
K hours
2.1
g
*Supply voltage must be discontinued at the end of short circuit duration.
PART NUMBER SYSTEM
D050505T-1W
Rated Power
Package Style
The 2nd Output Voltage
The 1st Output Voltage
Input Voltage
Product Series
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development
center, Science Ave., Guangzhou Science City,
Luogang district, Guangzhou,P.R.China.
Tel: 86-20-28203030
Fax:86-20-38601272
ISOLATION SPECIFICATIONS
Item
Isolation voltage
(Vin/Vout)
Isolation voltage
(Vo1/Vo2)
Isolation resistance
(Vin/Vout)
Isolation resistance
(Vo1/Vo2)
Isolation capacitance
(Vin/Vout)
Isolation capacitance
(Vo1/Vo2)
Test condition
Min.
Tested for 1 minute and 1mA max
1000
Tested for 1 minute and 1mA max
1000
Test at 500VDC
1000
Test at 500VDC
1000
Typ.
Max.
Unit
VDC
MΩ
60
pF
60
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
D_T-1W
B/1-2012
Page 1 of 3
OUTPUT SPECIFICATIONS
Item
APPLICATION NOTE
Test Conditions
Min.
Output power
Typ.
0.1
For Vin change of ±1%
Line regulation
Load regulation
Max.
Unit
1
W
±1.2
10% to 100% load(5V output)
12.8
15
10% to 100% load(9V output)
8.3
10
10% to 100% load(12V output)
6.8
10
10% to 100% load(15V output)
6.0
10
Output voltage accuracy
%
See tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
50
Switching frequency
Full load, nominal input
100
±0.03
%/°C
75
mVp-p
KHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of
Power Converter section, application notes.
Operating Temp.(oC)
RECOMMENDED REFLOW SOLDERING PROFILE
260 o C
250
Temperatur e ( o C)
RECOMMENDED CIRCUIT
1 0 S ec M ax
22 0o C
200
L
Vo1
L
150
100
C
Vin
0V1
Vo2
L
DC DC
C
90 Sec Max
o
(>220 C)
GND
C
0V2
(Figure 1)
50
0
Vo1
Time ( sec .)
Vin
REG
0V1
Remark: The curve applies only to the hot air reflow soldering
TYPICAL CHARECTERISTICS
1) Requirement On Output Load
To ensure this module can operate efficiently and reliably, a minimum load is specified
for this kind of DC/DC converter in addition to a maximum load (namely full load).
During operation, make sure the specified range of input voltage is not exceeded, the
DC
DC
Vo2
GND
0V2
Vo1
REG
Vin
0V1
DC
DC
Vo2
REG
GND
0V2
minimum output load could not be less than 10% of the full load. If the actual output
(Figure2)
power is very small, please connect a resistor with proper resistance at the output end
in parallel to increase the load, or use our company’s products with a lower rated output
power (D_T –W2/W5).
2) Recommended testing circuit
If you want to further decrease the input/output ripple, an “LC” filtering network may
be connected to the input and output ends of the DC/DC converter, see (Figure1).
It should also be noted that the inductance and the frequency of the “LC” filtering
network should be staggered with the DC/DC frequency to avoid mutual interference.
However, the capacitance of the output filter capacitor must be proper. If the
capacitance is too big, a startup problem might arise. For every channel of output,
provided the safe and reliable operation is ensured, the greatest capacitance of its filter
capacitor sees (Table 1).
EXTERNAL CAPACITOR TABLE (TABLE 1)
Vin
Cin
Vout
Cout
(VDC)
(µF)
(VDC)
(µF)
5
4.7
5
4.7
12
2.2
9
2.2
-
-
12
1
-
-
15
0.47
It’s not recommended to connect any external
capacitor in the application field with less than 0.5 watt
output.
3) Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current
protection is a linear voltage regulator with overheat protection that is connected to the
input or output end in series (Figure2).
4) Overload Protection
Under normal operating conditions, the output circuit of these products has no
protection against overload. The simplest method is to connect a self-recovery fuse in
series at the input end or add a circuit breaker to the circuit.
5) Cannot use in parallel and hot swap
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
D_T-1W
B/1-2012
Page 2 of 3
OUTLINE DIMENSIONS& RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
17.78 [0.700]
9
8
( Top View )
3
12
5
6
0.60 [0.024]
7
16.68 [0.657]
10
17.78 [0.700]
14 13 12
12.70 [0.500]
15.24 [0.600]
14 13 12
10 9
8
1
5
7
2
3
6
2.10 [0.083]
2.54 [0.100]
1.00 [0.039]
( Front View )
5.75 [0.226]
Note: gr id 2.54*2. 54m m.
6.00 [0.236]
FOOTPR INT DETAILS
A
12.22 [0.481]
0.25 [0.010]
A
5 max
1.30 [0.051]
Note:
Unit: mm[inch]
Pin section tolerances: ± 0.10mm[± 0.004inch]
General tolerances: ± 0.25mm[± 0.010inch]
TUBE OUTLINE DIMENSIONS
Pin
1
2
5
6
9
10
Function
GND
Vin
Other s
NC
0V1
Vo1
Vo2
0V2
NC:No Connection
REEL PACKING OUTLINE DIMENSIONS
Taping dimension:
4.00 [0.157]
∅1.50[0.059]
21.50 [0.846]
14.30 [0.563]
2.00 [0.079]
1.75 [0.069]
14.20[0.559]
18.00[0.709]
9.80 [0.386]
7.60 [0.299]
18.20[0.717]
8.00 [0.315]
0.50[0.020]
32.00 [0.260]
∅1.50[0.059]
8.30 [0.327]
6.80[0.268]
24.00 [0.945]
37.40 [1.472]
Note:
Unit: mm[inch]
General tolerances: ± 0.50mm[± 0.020inch]
L=530mm[20.866inch] Devices per tube quantity: 28pcs
L=220mm[8.661inch] Devices per tube quantity: 10pcs
Short tube inner package dimensions: L*W*H= 255*170*80mm
Short tube outer package dimensions(with six inner package boxes):
L*W*H= 375*280*270mm
Long tube inner package dimensions: L*W*H= 580*200*100mm
Long tube outer package dimensions(with two inner package boxes):
L*W*H= 600*215*220mm
Long tube outer package dimensions(with three inner package boxes):
L*W*H= 600*215*325mm
∅100.00 [3.937]
∅330.00 [12.992]
Taping reel dimension:
∅13.00 [0.512]
∅21.50 [0.846]
Note:
Unit:mm[inch]
General tolerances: ±0.50mm[±0.020inch]
Per reel of packing quantity:400pcs
Innerpackage carton dimensions:L*W*H=365*350*105mm
Tube Quantity:800pcs
Outerpackagecartondimensions:L*W*H=390*360*245mm
Tube Quantity:1600pcs
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the life
of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. Only typical models listed, other models may be different, please contact our technical person for more details.
4. In this datasheet, all the test methods of indications are based on corporate standards.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
D_T-1W
B/1-2012
Page 3 of 3