MACOM 2-1393030-9

Catalog 1308242
Issued 3-03 (PDF Rev. 11-05)
P&B
SSR series
“Hockey Puck”
Solid State Relay With
Paired SCR Output
File E81606
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
Engineering Data
• Standard “hockey puck” package.
• Enhanced noise immunity (designed to meet level 3 requirements of
European EMC Directive).
• LED indicator.
• Inverse parallel SCR output.
• 25, 50, & 125A rms versions.
• 120/240VAC & 480VAC output types.
• Zero voltage and random voltage turn-on versions.
• AC & DC input versions.
• 4,000V rms optical isolation.
• Floating terminal design.
Form: 1 Form A (SPST-NO).
Duty: Continuous.
Isolation: 4,000V rms minimum.
Capacitance: 8 pf typical (input to output).
Temperature Range:
Storage: –40°C to +100°C
Operating: –20°C to +80°C
Case Material: Plastic, UL rated 94V-0.
Case and Mounting: Refer to outline dimension.
Termination: Refer to outline dimension.
Approximate Weight: 3.5 oz. (98g).
Ordering Information
Sample Part Number
SSR -240
25
D
1. Basic Series: SSR = "hockey puck" inverse parallel SCR output solid state relay
2. Line Voltage: 240 = 24 - 240VAC
3. Input Type & Voltage:
480 = 48 - 660VAC
A = 90 - 280VAC
D = 3 - 32VDC (240V line voltage model) / 4 - 32VDC (480V line voltage model)
4. Maximum Switching Rating/Output: 25 = .1 - 25A rms, mounted to heatsink
50 = .1 - 50A rms, mounted to heatsink
125 = .1 - 125A rms, mounted to heatsink
5. Options: Leave Blank = Zero voltage turn-on
R = Random voltage turn-on (phase controllable)
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
SSR-240A25
SSR-240A50
SSR-240D25
SSR-240D25R
SSR-240D50
SSR-480D125
Input Specifications
DC Input
AC Input
Parameter
Zero V Turn-on Units
Zero and Random V Turn-on Units
240VAC Rated Models
480VAC Rated Models
90 - 280VAC
3 - 32VDC
4 - 32VDC
Must Operate Voltage VIN(OP) (Min.)
90VAC
3VDC
4VDC
Must Release Voltage V IN(REL) (Min.)
10VAC
1VDC
1VDC
Input Current (Max.)
15mA
15mA
15mA
Control Voltage Range V IN
Dimensions are shown for
1104 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Catalog 1308242
Issued 3-03 (PDF Rev. 11-05)
P&B
Output Specifications (@ 25° C, unless otherwise specified)
Parameter
Nom. Line Voltage
Conditions
Units
120/240V Model
25A Models
50A Models
125A Models
24 - 280
480V Model
V rms
V rms
120/240 Model
V peak
±600
Load Current Range I L*
480V Model
120/240 & 480V Models
V peak
A rms
.05 - 25
±1200
.1 - 50
.1 - 125
Single Cycle Surge Current (Min.)
120/240 & 480V Models
A peak
250
750
1,700
Load Voltage Range VL
Repetitive Blocking Voltage (Min.)
Leakage Current (Off-State) (Max.)
Resistive
120/240V Model
f = 60 Hz. VL = 240V rms
48 - 660
.1
mA rms
480V Model
f = 60 Hz. VL = 480V rms
.25
On-State Voltage Drop (Max.)
120/240 & 480V Models
I L = Max.
1.35
Static dv/dt (Off-State) (Min.)
120/240 & 480V Models
V/μs
Thermal Resistance, Junction to Case
(R θ J-C) (Max.)
120/240 & 480V Models
°C/W
500
0.4
.15
0.25
ms
8.3 for Zero Voltage Turn-On DC input types,
20 for Zero Voltage Turn-On AC input types,
0.02 for Random Voltage Turn-On Models
f = 60 Hz.
ms
8.3 for DC input types, 30 for AC input types
t = 8.3 ms
A 2 Sec.
Turn-On Time (Max.)
120/240 & 480V Models
Turn-Off Time (Max.)
120/240 & 480V Models
I 2 T Rating
120/240 & 480V Models
Load Power Factor Rating
120/240 & 480V Models
I L= Max.
f = 60 Hz.
937
2,458
12,000
0.5 - 1.0
*See Derating Curves
Electrical Characteristics (Thermal Derating Curves)
50A Units
25A Units
125A Units
Heatsink Recommendations
• We recommend that solid state relay modules be mounted to a
heatsink sufficient to maintain the module’s base temperature at less
than 85°C under worst case ambient temperature and load conditions.
• The heatsink mounting surface should be a smooth (30-40 micro-inch
finish), flat (30-40 micro-inch flatness across mating area), un-painted
surface which is clean and free of oxidation.
• An even coating of thermal compound (Dow Corning DC340 or
equivalent) should be applied to both the heatsink and module mounting
surfaces and spread to a uniform depth of .002” to eliminate all air
pockets.
• The module should be mounted to the heatsink using two #10 screws.
Operating Diagrams
Outline Dimensions
1.850
(47.0)
1
-4
CONSTANT
CURRENT
DC INPUT
+3
ZERO
VOLTAGE
CIRCUIT†
OUTPUT
1
ZERO
VOLTAGE
CIRCUIT†
OUTPUT
Random Turn-on Units have a Random Turn-on circuit
instead of Zero Voltage Circuit
Dimensions are shown for
reference purposes only.
1.100
.470 (27.94)
(11.9)
1.750
(44.45)
1.000
(25.4)
2
EQUIVALENT CIRCUIT ONLY
†
.870
(22.1)
.875
(22.23)
4
3
LED INDICATOR
2
EQUIVALENT CIRCUIT ONLY
AC INPUT
1.700
(43.18)
Dimensions are in inches over
(millimeters) unless otherwise
specified.
2.250
(57.15)
Specifications and availability
subject to change.
.785
(19.94)
.250
(6.35)
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
1105