Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) W6/W9 series Magnetic Hydraulic P&B Circuit Breakers Features Typical Resistance and Impedance • Designed for the international market. UL Recognized (UL1077 and UL1500), CSA Accepted and VDE approved. • Ratings to 50 amps. • Heavy duty #10-32 stud connections. (W9) • Quick-connect or screw terminals. (W6) • Optional 10 amp auxiliary switch. • Several delay curve options. • Choice of toggle or rocker actuator per pole or per unit (W6). • Optional relay/remote trip pole available. • Trip-free operation. 0.2 1.0 2.0 5.0 10.0 20.0 30.0 40.0 50.0 Agency Approvals Recognized as Supplementary Protector under UL 1077. Available models meet Ignition Protection requirements in accordance with UL1500. File E69543. CSA: Accepted as a Supplementary Protector. File LR15734. VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment) License No. 73782. UL: Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to confirm the product meets the requirements for a given application. Electrical Data Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details. Calibration: Breakers will hold 100% of rated current. Breakers may trip between 101% and 124% of rated load (134% for AC/DC units). Breakers must trip at 125% of rated load and above (135% for AC/DC units). Dielectric Strength: 50/60 Hz., 1500V: DC, 1100V. Insulation Resistance: 100 Megohms at 500VDC. Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load. Units tested at six cycles per minute, 1 second on and 9 seconds off at 25°C ambient. Relay Trip Coil: (Ratings applicable to all W6 models with this option) 24 to 277VAC, 150mA minimum available current; 6 to 48VDC, 300mA minimum available current. 50/60 Hz. Impedance (Ohms) DC Resistance (Ohms) Current (Amps) 90 1.2 0.28 0.04 0.013 0.004 0.0027 0.002 0.0015 90 1.2 0.28 0.04 0.013 0.005 0.004 0.002 0.0015 Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%. Mechanical/Environmental Data Operating Temperature: -40°C to +85°C. Humidity: Meets requirements of Mil-STD-202 method 103. Shock: Tested per Mil-STD-202, method 213, test condition C (100g @ 6 ms). Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm) total excursion in 2 planes. Fungus And Moisture Resistance: Special moisture resistant finish applied to all ferrous parts. Plastic parts are made of inherently fungus resistant material. Marking: International “1” and “0” symbols are marked on the toggle for both W6 and W9. W9 units have “ON” and “OFF” molded into the area at the base of the toggle. On a special order basis, graphics can be imprinted on the rockers of rocker actuated W6 units. VDE approved versions of rocker actuated W6 breakers have their rockers imprinted with “1” and “0.” Mounting: Units are mounted with two #6-32 screws from the front of the panel. Metric models for use with M3 x 0.5 screws are available. To maintain published performance specifications, units should not be mounted more than 90° from their normal upright position. Weight: Approximately 2.5 ounces per pole. Approvals and Ratings Table 1 W6 Series Maximum Voltage 65 277 277 277/480 UL1077/CSA (All Circuit Functions) Frequency (Hz) DC 50/60 50/60 50/60 W9 Series Maximum Voltage 65 277 277/480 Phase 1 1 3Ø-Wye Current Rating (Amps) 0.2 - 50 0.2 - 20 21 - 50 0.2 - 20 Interrupting Capacity (Amps) 2,000 5,000 2,500 5,000 UL1077/CSA (All Circuit Functions) Frequency (Hz) DC 50/60 50/60 Phase 1 3Ø-Wye Current Rating (Amps) 0.2 - 50 0.2 - 50 0.2 - 20 Interrupting Capacity (Amps) 2,000 5,000 5,000 W6 or W9 Series Maximum Voltage 65 250 250 415/240 Frequency (Hz) DC 50/60 50/60 50/60 W6 or W9 Series Maximum Voltage 48 125/250 250 VDE (Circuit Function X) Phase 1 1 3Ø Current Rating (Amps) 0.2-50 0.2-30 31-50 0.2-30 Interrupting Capacity (Amps) 2,000 5,000 2,000 5,000 UL1500 (Circuit Function X) Frequency (Hz) DC 50/60 50/60 Phase 1 3Ø-Wye Current Rating (Amps) 0.2 - 50 0.2 - 50 0.2 - 50 Interrupting Capacity (Amps) 3,000 1,000 1,000 Auxiliary Switch Ratings Table 2 UL/CSA Switch Number Voltage 50/60 Hz. Current (Amps) Terminals WxTxL A 125 10 .093 x .020 x .250 (2.36 x .51 x 6.40) Revised 03-10 www.tycoelectronics.com Dimensions are in inches over (millimeters) unless otherwise specified. Dimensions are shown for reference purposes only. Specifications and availability subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 1 Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) Time vs. Current Trip Curves For W6 Series and W9 Series AC 50/60 Hz. DC & 50/60 Hz. TRIP TIMES OVERLOAD @ 50/60 Hz. & DC @ 400 Hz. 125% 150% 200% 400% 600% 800% 100 10 100 ms max. 55 ms max. 30 ms max. 15 ms max. 12 ms max. 12 ms max. May Trip 100 ms max. 30 ms max. 15 ms max. 12 ms max. 12 ms max. 1 .1 100 10 10 - 150 2.2 - 20 .2 - 2 .03 - .75 .007 - .15 .005 - .04 1 .1 .001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING OVERLOAD TRIP TIMES (SEC.) 125% 40 - 500 200% 9 - 100 400% 2 - 20 600% .8 - 10 800% .1 - 4.5 1000% .009 - 2 1000 100 10 1 .1 10,000 1000 TIME IN SECONDS MOTOR START / LONG DELAY CURVE 10 HIGH INRUSH 50/60 Hz. AC 125% 200% 400% 600% 800% 1000% 100 10 1 1 - 15 .15 - 1.5 .03 - .25 .007 - .15 .003 - .08 .003 - .04 .1 .01 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING CURVE 12 HIGH INRUSH 50/60 Hz. 125% 200% 400% 600% 800% 1000% 10 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING CURVE 13 HIGH INRUSH 50/60 Hz. 10,000 OVERLOAD TRIP TIMES (SEC.) 100 .001 0 10 - 150 3 - 25 .5 - 2.5 .15 - 1 .015 - .7 .009 - .35 1 .1 125% 200% 400% 600% 800% 1000% 100 10 .8 - 30 .15 - 2.5 .03 - .3 .02 - .15 .009 - .12 .009 - .09 1 .1 .01 .01 .001 0 .001 0 .001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING OVERLOAD TRIP TIMES (SEC.) 1000 .01 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING OVERLOAD TRIPTIMES (SEC.) 1000 .01 10,000 TIME IN SECONDS 125% 200% 400% 600% 800% 1000% CURVE 3 SHORT DELAY 50/60 Hz. 10,000 OVERLOAD TRIP TIMES (SEC.) 1000 .01 .001 0 CURVE 2 STANDARD DELAY 50/60 Hz. TIME IN SECONDS TIME IN SECONDS 1000 10,000 TIME IN SECONDS CURVE 0 INSTANTANEOUS TIME IN SECONDS 400 Hz. 10,000 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING DC TIME IN SECONDS 1000 125% 200% 400% 600% 800% 1000% 100 10 1 2 - 55 .60 - 8 .1 - 1.5 .02 - .5 .004 - .05 .004 - .025 .1 10,000 1000 CURVE 3 SHORT DELAY DC 125% 200% 400% 600% 800% 1000% 100 10 1 .6 - 7 .16 - 1.5 .03 - .25 .01 - .13 .004 - .05 .003 - .015 .1 100 10 1 .1 .01 .01 .01 .001 0 .001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING OVERLOAD TRIP TIMES (SEC.) 125% 80 - 700 200% 15 - 150 400% 2 - 20 600% .70 - 10 800% .10 - 3 1000% .01 - .1 1000 .001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING CURVE 53 DC HIGH INRUSH 10,000 OVERLOAD TRIP TIMES (SEC.) TIME IN SECONDS OVERLOAD TRIP TIMES (SEC.) TIME IN SECONDS CURVE 2 STANDARD DELAY DC 10,000 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING AC/DC 10,000 CURVE 34 DC, 50/60 Hz. STANDARD DELAY OVERLOAD TRIP TIMES (SEC.) TIME IN SECONDS 1000 135% 200% 400% 600% 800% 1000% 100 10 1 - 90 .60 - 20 .095 - 2 .02 - .95 .002 - .45 .002 - .09 1 .1 .01 .001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 LOAD CURRENT AS A PERCENT 135 OF BREAKER RATING Note: For instantaneous curves for all voltages refer to Curve 0 Instantaneous under the AC 50/60 Hz. heading. Pulse Tolerance Specifications Pulse tolerance is defined as a single pulse of a half sine wave (1/2 cycle or 8 milliseconds) that will not trip the breaker. An inertia wheel for increased pulse tolerance is available by specifying “P” after the time delay curve number in the ordering information. The table at right lists pulse tolerance values of standard and inertia delay models. Voltage AC 50/60 Hz. Pulse Tolerance Value Time Delay Curve Standard Inertia Delay 2 3 10 12 13 7.5 6 18 18 18 18 18 30 30 30 To determine pulse tolerance multiply breaker rating by value in table. For example, a 2A breaker with time delay curve 3 has a standard pulse tolerance of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance of 36A (2A x 18). 2 Revised 03-10 www.tycoelectronics.com Dimensions are in inches over (millimeters) unless otherwise specified. Dimensions are shown for reference purposes only. Specifications and availability subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) Ordering Information W6 Series Typical Part No. > W 67- X 2 Q 1 2- 20 45.0 50.0 Consult factory for other values. 1. Circuit Breaker Mounting: W = #6-32 mounting threads. M = M3.0 x 0.5 mounting threads. 2. Number of Poles: 67 = Single pole 68 = Two pole 69 = Three pole 70 = Four pole 3. Circuit Function: (Only X is VDE approved) A = Series trip with auxiliary switch (.093” QC) X = Series trip D = Series trip with auxiliary relay trip pole (requires extra pole package, 3 pole (4 pole package) max., must specify #10-32 screw terminals below, but relay trip pole will be equipped with .250” QC term. only, not UL), relay trip pole will be on the right side of the breaker when viewed from the front. 4. Actuator: One actuator per pole 1 = Black toggle 3 = Black rocker 4 = White rocker 2 = White toggle 5 = Red rocker 6 = Grey rocker One actuator per unit 8 = White toggle 7 = Black toggle J = Black rocker 9 = Red toggle 5. Termination: Q = .250” QC (DIN 46 244) [30A Max. UL/CSA; 25A Max. VDE] S = #8-32 screw [30A Max.] T = #10-32 screw [50A Max.] U = #8-32 screw, nickel plated, bent inward 30° [30A Max.] V = #10-32 screw, nickel plated, bent inward 30° [50A Max.] Notes: #10-32 termination must be used for all ratings of greater than 30 amps. #10-32 termination must be specified for circuit function D, but relay trip pole will be equipped with .250” QC. 6. Maximum Line Voltage: (See Table 1 for current ranges) UL/CSA 1 = 277VAC, 50/60 Hz. TYPES 2 = 277/480VAC, 50/60 Hz. [20A Max.] (Requires insulating barriers, see outline dimension drawing) 5 = 65VDC 7 = AC/DC 277VAC, 50/60 Hz. or 65VDC (Time delay curve 34 must be specified.) 8 = AC/DC 120VAC, 120/240VAC, 48VDC (Agency Approval M [UL1500] and time delay curve 34 must be specified.) VDE TYPES 1 = 250VAC, 415/240VAC 5 = 65VDC 7 = AC/DC 250VAC, 415/240VAC, 65VDC (Time delay curve 34 must be specified.) 7. Time Delay Curve: 0 = Instantaneous 2 = Standard delay 3 = Short delay 53 = DC high inrush 10 = AC high inrush motor start / long delay 12 = AC high inrush version of #2 13 = AC high inrush version of #3 34 = Combination AC/DC standard delay Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve. See delay curve section for availability and details. 8. Amp Rating: 0.20 0.50 0.25 0.75 1.0 1.5 2.0 2.5 3.0 3.5 4.0 5.0 6.0 7.0 7.5 8.0 9.0 10.0 11.0 12.0 15.0 20.0 25.0 30.0 35.0 40.0 9. Agency Approval: Blank = UL1077/CSA breaker V = VDE approved breaker without auxiliary switch M = UL1077/UL1500 ignition protected breaker Authorized distributors are more likely to stock the following items. W67-A2Q12-5 W67-A2Q12-10 W67-X2Q10-3 W67-X2Q10-5 W67-X2Q12-2 W67-X2Q12-3 Revised 03-10 www.tycoelectronics.com W67-X2Q12-5 W67-X2Q12-7 W67-X2Q12-10 W67-X2Q12-15 W67-X2Q12-20 W67-X2Q12-30 W67-X2Q13-1 W67-X2Q13-2 W67-X2Q13-3 W67-X2Q13-10 W67-X2Q13-15 W67-X2Q13-20 Dimensions are in inches over (millimeters) unless otherwise specified. W67-X2Q13-25 W67-X2Q13-30 W67-X2Q50-5 W67-X2Q50-10 W67-X2Q52-5 W67-X2Q52-10 W67-X2Q52-15 W67-X2Q52-20 W67-X2Q52-30 W67-X2Q110-15 W67-X2Q110-20 W68-X2Q12-3 Dimensions are shown for reference purposes only. Specifications and availability subject to change. W68-X2Q12-5 W68-X2Q12-7 W68-X2Q12-10 W68-X2Q12-15 W68-X2Q12-20 W68-X2Q12-25 W68-X2Q12-30 W68-X2Q13-15 W68-X2Q110-10 W68-X2Q110-20 W69-X2Q12-5 W69-X2Q12-10 USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 W69-X2Q12-15 W69-X2Q12-20 W69-X2Q12-25 W69-X2Q12-30 W69-X2Q110-20 W69-X2Q110-30 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 3 Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) Ordering Information W9 Series Typical Part No. > W 91- X 1 2- 1 20 1. Circuit Breaker Mounting: W = #6-32 mounting threads. M = M3.0 x 0.5 mounting threads. 2. Number of Poles: 91 = Single pole 92 = Two pole 93 = Three pole 94 = Four pole 3. Circuit Function: (Only X is VDE approved) A = Series trip with auxiliary switch (.093” QC) X = Series trip D = Series trip with auxiliary relay trip pole (requires extra pole package, 3 pole max., not UL) 4. Actuator: One actuator per pole: 1 = Black toggle 2 = White toggle 5. Maximum Line Voltage: (See Table 1 for current ranges) UL/CSA 1 = 277VAC, 50/60 Hz. TYPES 2 = 277/480VAC, 50/60 Hz. [20A Max.] 5 = 65VDC 7 = AC/DC 277VAC, 50/60 Hz. or 65VDC (Time delay curve 34 must be specified.) 8 = AC/DC 120VAC, 120/240VAC, 48VDC (Agency Approval M [UL1500] and time delay curve 34 must be specified.) VDE TYPES 1 = 250VAC, 415/240VAC 5 = 65VDC 7 = AC/DC 250VAC, 415/240VAC, 65VDC (Time delay curve 34 must be specified.) 6. Time Delay Curve: 0 = Instantaneous 2 = Standard delay 3 = Short delay 53 = DC high inrush Notes: 10 = AC high inrush motor start / long delay 12 = AC high inrush version of #2 13 = AC high inrush version of #3 34 = Combination AC/DC standard delay Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve. See delay curve section for availability and details. 7. Amp Rating: 0.20 0.75 0.25 1.0 0.50 1.5 2.0 2.5 3.0 3.5 4.0 5.0 6.0 7.0 7.5 8.0 9.0 10.0 11.0 12.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 Consult factory for other values 8. Agency Approval: Blank = UL1077/CSA approved breaker V = VDE approved breaker without auxiliary switch M = UL1077/UL1500 ignition protected breaker Authorized distributors are more likely to stock the following items. W91-X112-1 W91-X112-2 W91-X112-3 W91-X112-5 W91-X112-7 W91-X112-10 4 Revised 03-10 www.tycoelectronics.com W91-X112-15 W91-X112-20 W91-X112-40 W91-X112-50 W91-X113-5 W91-X113-10 W91-X113-15 W91-X150-5 W91-X152-10 W91-X152-15 W91-X152-20 W91-X152-30 Dimensions are in inches over (millimeters) unless otherwise specified. W91-X152-40 W91-X152-50 W91-X1110-20 W92-X112-1 W92-X112-2 W92-X112-3 W92-X112-5 W92-X112-7 W92-X112-10 W92-X112-15 W92-X112-20 W92-X112-25 Dimensions are shown for reference purposes only. Specifications and availability subject to change. W92-X112-30 W92-X112-40 W92-X112-50 W92-X113-15 W92-X113-20 W92-X1110-20 W92-X1110-30 W93-X112-5 W93-X112-10 W93-X112-15 W93-X112-20 W93-X112-25 USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 W93-X112-30 W93-X112-40 W93-X112-50 W93-X1110-20 W93-X1110-30 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) Outline Dimensions - Toggle Actuator Models W6 Series Panel Mounting Cutout 2.043 (51.89) .235 (5.97) 1.640 (41.66) .66 (16.8) .245 (6.22) ( ON LINE A .750 (19.05) Ø .625 +.010 -.000 15.88 +0.25 -0.00 1 PER POLE ) 29° 1.520 (38.61) 1.660 (42.16) 1.048 (26.62) 30° OFF B Ø .156 [2 PLACES PER POLE] (3.96) LOAD W6 Series – One Actuator Per Pole 1 Pole Ø .590 (15.00) 2 Pole .750 (19.05) 3 Pole 1.500 (38.10) 4 Pole 3.000 (76.20) 2.250 (57.15) 1.660 (42.16) 2.000 (50.80) 1.05 (26.67) 1.22 (31.00) 6.32 TH'D. .14 (3.56) DP. TYP. M3 X 0.5 OPTIONAL Note: Multi-pole models furnished with separate handle tie hardware. W6 Series – One Actuator Per Unit 1 Pole Ø .590 (15.00) 2 Pole .750 (19.05) 3 Pole 4 Pole 2.250 (57.15) 1.500 (38.10) 3.000 (76.20) 1.660 (42.16) 2.000 (50.80) 1.05 (26.67) 1.22 (31.00) 6.32 TH'D. .14 (3.56) DP. TYP. M3 X 0.5 OPTIONAL Note: 4-pole models furnished with separate handle tie hardware. 480V Model with Barriers 2.250 (57.15) Model with Aux. Relay Trip Pole .269 (6.83) 2.778 (70.56) Note: W68 -D model shown. Note that the auxiliary relay trip pole is on the right. #10-32 screw terminals must be specified with this option; however, the terminals on the relay trip pole are 0.250” quick connects. The relay pole is self-opening, so the trip current can remain energized indefinitely. 2.530 (64.26) .266 (6.76) Note: 3-pole model shown. Termination Options Notes: 1. Terminal protrusion dimensions are referenced from back of mounting panel. 2. Main terminals are male quick connect type .250 (6.35) wide x .031 (.79) thick x .377 (9.58) long. Optional 8-32 x .250 (6.35) or 10-32 x .250 (6.35) screw type. 3. Panel mounting cutout detail mtg. detail tol.: ± .005 (.13) unless noted. Add additional cutouts to correspond to number of poles. Outline drawing tolerance ± .015 (.38) unless noted. UL/CSA Models W/Screw Terminals .235 (5.97) VDE Models W/Screw Terminals UL/CSA/VDE Models W/Aux. Switch 2.032 (51.61) LINE 2.380 (60.45) LINE A A LINE LINE A .416 (10.56) C 1.058 (26.97) .827 (21.00) NO 1.520 (38.61) NC B LOAD Revised 03-10 www.tycoelectronics.com UL/CSA Models W/Terminals Bent 30° Dimensions are in inches over (millimeters) unless otherwise specified. B LOAD Dimensions are shown for reference purposes only. Specifications and availability subject to change. LOAD B LOAD USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 5 Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) Outline Dimensions - Optional Toggle Guards W6 Series .03 (.76) .95 (24.1) .313 (7.95) 2.185 INSIDE (55.50) 1.093 (27.76) .75 .75 (19.05) (19.05) .2 x R1.0 (25.4) .47 (11.94) .17 (4.32) .08 (2.03) 1.375 INSIDE (34.92) .313 (7.95) .75 (19.05) .625 INSIDE (15.88) .78 (19.8) .17 REF. (4.32) .625 (15.88) 2.00 (50.8) 1.66 (42.16) 2x .27 DIA. (6.86) .44 (11.18) .53 (13.46) 2 x .16 DIA. (4.06) 4 x .16 DIA. (4.06) 84-004 (For 1 Pole Breaker) 6 x .16 DIA. (4.06) 84-005 (For 2 Pole Breaker) 84-004 toggle guard shown with W67 series circuit breaker mounted in a panel. .20 (5.08) 84-006 (For 3 Pole Breaker) Optional toggle guards may be ordered separately for use on W6 toggle actuator models. These guards help to prevent accidental operation and allow the breaker to be locked in the “off” position. Outline Dimensions - Rocker Actuator Models W6 Series 1 Pole 2, 3 & 4 Pole, One Actuator Per Pole (Shown with optional “ON” and “OFF” graphics) 3.000 (76.20) .750 (19.05) 1.769 (44.93) .240 (6.10) LOAD .392 (9.96) .774 (19.65) .180 (4.57) 4 POLE 3 POLE D 2.000 (50.80) 1.660 (42.16) 1.520 (38.61) LINE 1.500 (38.10) 2 POLE .375 (9.53) 2.250 (57.15) 2.600 (66.04) OFF 1.30 (33.0) A .388 (9.86) ON TAPPED FOR #6-32 M3 X 0.5 OPTIONAL 2.435 (61.85) .375 (9.53) .750 (19.05) .750 (19.05) .750 (19.05) 2, 3 & 4 Pole, One Actuator Per Unit 1.500 (38.10) 2.250 (57.15) 3.000 (76.20) .388 (9.86) 2.000 (50.80) 2.600 (66.04) 1.660 (42.16) 1.660 (42.16) .375 (9.53) .375 (9.53) Panel Mounting Cutout .375 (9.53) .750 (19.05) .750 (19.05) TAPPED FOR #6-32 M3 X 0.5 OPTIONAL 6 .750 (19.05) 1.500 (38.10) Revised 03-10 www.tycoelectronics.com .375 (9.53) .750 (19.05) .750 (19.05) .750 (19.05) .750 (19.05) VDE Rocker Marking .750 (19.05) .750 (19.05) .205 (5.21) 1.250 (31.75) 1.660 (42.16) 1 POLE 2 POLE 3 POLE 4 POLE .750 (19.05) 2.250 (57.15) 3.000 (76.20) I O Notes: 1. Outline drawing tolerance ± .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters. 2. Mounting Detail Tol.: ± .005 (.13) unless noted Ø .156 (3.96) TYP. 2 PER POLE Dimensions are in inches over (millimeters) unless otherwise specified. Dimensions are shown for reference purposes only. Specifications and availability subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) Outline Dimensions W9 Series Series Trip Model Series Trip Model .060 (1.52) .375 .281 (9.52) (7.14) 1.845 (46.86) 1.15 (29.21) LINE ON 29° 1.940 (49.28) 30° .750 (19.05) .375 (9.53) .313 (7.95) Note: 1. Top mounted plate (shown with broken line) is present only on UL1500 models. .060 (1.52) ON ON .375 (9.53) .218 (5.54) 2.065 (52.45) OFF OFF .750 (19.05) ON ON OFF OFF .750 (19.05) ON ON .750 (19.05) ON ON .398 (10.11) ON ON OFF OFF OFF OFF OFF OFF OFF 1.438 (36.53) 2.50 (63.5) LOAD #10-32 STUD TERMINATION .14 2.10 (3.56) (53.34) 2.50 (64.00) .74 (18.8) Series Trip Model With Common Enclosed Auxiliary Switch .281 (7.14) 2 POLE 1.500 (38.10) 2.250 3POLE (57.15) 3.000 (76.20) 1 POLE TAPPED #6-32 X .16 (4.06) DEEP M3 X 0.5 OPTIONAL Panel Mounting Cutout Detail .732 (18.59) 2.46 (62.48) 'A' STYLE .750 (19.05) .750 (19.05) .750 (19.05) .385 (9.78) .907 (23.04) LINE 1.940 (49.28) 1.450 (36.83) C NO 2.065 (52.45) NC LOAD 2X Ø .156 (3.96) PER POLE 2.50 (64.00) 4 POLE 3.04 (77.2) 2.28 (57.9) .76 1.52 (19.3) (38.6) Notes: 1. Terminal protrusion dimensions are referenced from the back of the mounting panel. 2. Mounting detail tolerance ±.005 (13) unless noted. 3. Outline drawing tolerance ± .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters. 1 POLE 2 POLE 3 POLE 4 POLE Disclaimer: While Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this document, Tyco Electronics cannot assure that this information is error free. For this reason, Tyco Electronics does not make any representation or offer any guarantee that such information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information at any time. Tyco Electronics expressly disclaims any implied warranty regarding the information contained herein, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose. Tyco Electronics‘ only obligations are those stated in Tyco Electronics’ Standard Terms and Conditions of Sale. Tyco Electronics will in no case be liable for any incidental, indirect or consequential damages arising from or in connection with, including, but not limited to, the sale, resale, use or misuse of its products. Users should rely on their own judgment to evaluate the suitability of a product for a certain purpose and test each product for its intended application. In case of any potential ambiguities or questions, please don’t hesitate to contact us for clarification. © 2010 by Tyco Electronics Corporation. All Rights Reserved. P&B, Potter & Brumfield, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors. Revised 03-10 www.tycoelectronics.com Dimensions are in inches over (millimeters) unless otherwise specified. Dimensions are shown for reference purposes only. Specifications and availability subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 7